Mini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater

Similar documents
TO DO IF YOU SMELL GAS

GOLD Plus 30/40/60/80

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers

Indirect-Fired Water Heaters

Indirect Fired Water Heaters

Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119

Installation & Operation Manual Models: SIT030 - SIT119

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual PT-30 PT-40 PT-50 PT-60 PT-80 PT-120

Installation & Operation Manual Models: TSU

Installation & Operation Manual Models:

TO DO IF YOU SMELL GAS

GEOTHERMAL STORAGE TANKS

Indirect Water Heater * I N S T A L L A T I O N A N D M A I N T E N A N C E * M A N U A L

User s Information Manual

INSTALLATION AND OPERATING INSTRUCTIONS

H 2 INDIRECT-FIRED WATER HEATERS FOR SINGLE WATER HEATER INSTALLATIONS INSTALLATION, OPERATION & MAINTENANCE MANUAL

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION OPERATION MAINTENANCE

Product Manual. Series 2 Indirect-Fired Water Heaters. Maintenance Parts. Installation Startup

INDIRECT FIRED WATER HEATERS

INSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS

Installation & Operation Manual Models: SSS031, SSS041, SSS051, SSS081, & SSS119

Mighty Venter Power Vent System

Indirect Fired Water Heater

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

CER Series 2. Installation Instructions. Electric-Hydronic Boilers. Installer

Indirect Fired Water Heaters

INSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

SuperStor Glass Lined Storage Tank

Models F and B Size Option Package by Option Designation, Model Size, Voltage, and P/N

Solar Indirect Water Heater

SuperStor Ultra Stainless Steel Storage Tank

Comfort Indirect Fired Water Heater

INSTALLATION AND OPERATING INSTRUCTIONS

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

STORAGE TANK INSTALLATION and OPERATION MANUAL

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

MASCOT Quick Setup Guide

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

Description/ Application

Installation Instructions

INSTALLATION GUIDE. AAN & AEN Series - Manufactured Housing Electric Furnace. 1. Safety Instruction. 2. Inspection ! CAUTION CAUTION `!

IMPORTANT WARNING CAUTION

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Trin & Stor Model Numbers: S, S-SR, SL Series Version Date:

INSTALLATION AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

PRO SERIES IMPORTANT SAFETY INFORMATION

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Get The Edge Over The Competition with The Summit

INSTALLATION INSTRUCTIONS

Brazed Plate Heat Exchangers TTP s Series

AHG**-0B Series Hydronic Air Handling Units

/99 USA. Installation Manual SU Save These Instructions!

SuperStor Contender Indirect Fired Water Heater

Champion Series INDIRECT-FIRED WATER HEATER. All Champion Series

Owner s Manual Therma-Stor II Heat Recovery System

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

HX Field Replacement Kit

Indirect Fired Water Heaters TR Series

TWINTEMP JR. HYDRONIC SYSTEM 2/2013

RL with INNOVATOR Doors

CER Series 2. Installation Instructions. Electric-Hydronic Boilers. Installer

Technical Specifications Installation & Maintenance Manual NOTICE

Solar Indirect Water Heater

Solar Storage Tank with Electric Backup Instruction Manual

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

H 2. Hot Water Storage/ Booster Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS OST30 OST40 OST60 OST60L OST80 OST80C OST115 OST115C

Addendum H to Brute LX 1295A Document 1372

WARNING CAUTION 50T INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS. Integrated Furnace Control

Contents. Hazard definitions

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Cool IR. Model C104 - Cooling System. Instruction Manual

Superstor Ultra NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTIONS

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

SLIDE-IN HEATING COIL INSTALLATION MANUAL BULLETIN

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

! WARNING. Before using product, read and understand instructions.

STAINLESS STEEL INDIRECT-FIRED WATER HEATER

Universal Fire Tube Boiler Wall Mount Models

Sun Bandit Hybrid Water Heater Installation and Operation Solar Hybrid Energy Systems Patent(s) Pending

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Boiler & Water Heater

Owner s Manual for. PennStoker

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

RESIDENTIAL ELECTRIC WATER HEATER

TABLE 1 Electrical Specifications

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Boiler Manual. Series 3 Oil-Fired Water Boilers. Installation Maintenance Parts

RESIDENTIAL ELECTRIC WATER HEATERS

INDIRECT-FIRED WATER HEATER

Thermostatic mixing valves with interchangeable cartridges

Transcription:

Installation and Operation Instructions Document 2101B Installation and Operation Instructions for Mini-Combo id Model MCH Induced Draft esidential Gas-Fired Space/Water Heater Note: This document is to be used in conjunction with Document 1080, Installation and Operating Instructions for Mini-Therm JVi boilers. WANING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. efer to this manual. For assistance or additional information consult a qualified installer, service agency, gas supplier, or call the factory. H2100200B

Page 2 LAAS HEATING SSTEMS TABLE OF CONTENTS SECTION 1. General Information 1A. Hazards and our Safety Hot Water Can Scald!... 3 SECTION 2. Installation... 3 2A. Location... 5 2B. Heater Placement... 5 2C. Piping... 5 2D. Wiring... 6

Mini-Combo id Page 3 SECTION 1. General Information WANING This manual supplies information on the application, installation and operation of the indirect water heater unit. A complete instruction manual of the operation of the hydronic boiler (Document 1080) is supplied along with this manual. Both manuals should be reviewed completely before proceeding with the installation. Failure to follow the instructions provided may result in personal injury, death or substantial property damage. Any modifications to the boiler, water tank, gas and water connections, or wiring may void warranty. Consult the factory or local factory representative with any questions or problems regarding this equipment. Hazards and our Safety Hot Water Can Scald! Consumer Product Safety Commission and some states/provinces recommend a temperature setting of 130 F (54 C) or less. The water heater thermostat is factory set to approximately 120 F (49 C). If thermostat will be set above factory setting, install an anti-scald valve at either the water heater or at each hot water faucet. Tempering valves are not anti-scald valves since they do not have a positive shutoff in case cold water supply fails. They are not recommended for shower/tub service. If needed, install an antiscald valve at each shower/tub. Water heated to a temperature suitable for clothes washing, dish washing and other sanitizing needs can scald and cause permanent injury. Children and elderly, infirm, or physically handicapped persons are more likely to be injured by hot water. Never leave them unattended in a bathtub or shower. Never allow small children to use a hot water tap or draw their own bath. If anyone using hot water in the building fits this description, or if state/province laws or local codes require certain water temperature at hot water taps, take special precautions: Install an anti-scald valve at water heater or at each hot water faucet, bath, and shower outlet. Use lowest practical temperature setting. Studies have indicated that dangerous bacteria can form in potable water distribution system if certain minimum water temperatures are not maintained. Contact local health department for more information. SECTION 2. Installation This installation must conform with the instructions in this manual and, where applicable: Local, state, provincial, and national codes, laws, regulations and ordinances. In Canada CAN/CGA B149.1 or B149.2 installation Code. Where the recommendations made in this manual differ from local or national codes, the local or national codes take precedence. 2A. Location This water heater/boiler unit is not intended for outdoor installation. Select a convenient location where water leakage from the tank or connections will not result in damage to areas adjacent to the appliance or to lower floors of the structure. When a safe location cannot be found, install a suitable drain pan under the appliance, and pipe it to an adequate drain. 2 (51) 63.5 (1613) 25.25 (641) 29 (737) 4 (102) Figure 1. Closet Installation. 23 (584) 57.75 (1467) Top Clearance 2 (51) 2 (51) Dimensions shown in inches (mm).

Page 4 LAAS HEATING SSTEMS Check Valve Boiler Flue Collar 4 (102) Tank Pump 62.5 (1588).75 (19) 24 (610) Domestic Hot Water Outlet Cold Water Inlet 32.5 (826) 41.5 (1054) Tank Aquastat Drain Valve 60 (1521) Tank elief Valve 7 (178) 24 (610) 24 (610) 7 (178) 28 (711) Dimensions shown in inches (mm). Side View Front View Figure 2. Dimensional Information. Dimensions inches mm Size A 50 14 356 75 15 381 100 16 406 125 17 432 Boiler In/Out NPT (all sizes) 1¼ Gas NPT (all sizes) ½* Domestic Hot Water (all sizes) Inlet/Outlet NPT ¾ Minimum clearances from combustible surfaces: Left Side: 2" 51mm ight Side: 2" 51mm ear: 2" 51mm Front: 4" 102mm Top: 23" 584mm Service clearances: Allow 4" 102mm on each side for piping access. *¾" for model 125 Natural. Hot Water Supply Cold Water Supply Figure 3. Piping Schematic. Shut Off Valve Check Valve or Back-Flow Preventer Expansion Tan k Space Heating - efer to Document 1080 Boiler Tan k Union Mini-Combo Tan k Cold Water Inlet Figure 4. Typical Expansion Tank Installation.

Mini-Combo id Page 5 2B. Heater Placement The heater must be placed to provide clearances on all sides for maintenance and inspection. Allow 4 inches on each side for piping access. There must also be minimum distances maintained from combustible surfaces. Figure 1 shows minimum clearance from combustible surfaces. The Mini-Combo unit can be installed in a closet, as long as the minimum clearances are maintained. Special attention should be paid to the air supply opening to the closet. efer to Table 1. Net Free Area square inches sq. cm Model Inside Air Outside Air MC50 100 645 15 97 MC75 100 645 20 129 MC100 100 645 25 161 MC125 125 806 32 206 Area indicated is for one of two openings: One at floor level and one at the ceiling, so the total free area would be double the figures indicated. efer to Document 1080 for more information. Table 1. Minimum ecommended Air Supply. persons. Attach run-off tube to T&P valve and run tube within 6" (152mm) from floor. No reducing couplings, valves, or any other type of restriction is to be installed in this line. This runoff tube must be installed to allow free and complete drainage of both valve and run-off tube. Filling Storage Water Tank 1. Open hot water faucet in house to allow air in the tank and in piping to escape. 2. Open shut-off valve(s) in cold water supply line. 3. Open shut-off valve(s) in hot water supply line. 2C. Piping To prevent damage to the unit, all soldering is to be done prior to assembling the cold and hot water, and any other connections to the tank. Use suitable pipe dope or tape. Before piping the boiler to the heating system, be sure to install the system check valve (provided with the unit) onto the inlet (return) tee of the boiler with arrow pointed downward (see Figure 3). If anti-freeze is used in boiler system, local codes may require a backflow preventer on cold supply line. Use anti-freeze specifically intended for hydronic heating system. Inhibited propylene glycol is recommended. WANING Do not use automotive or ethylene glycol antifreeze, or any undiluted anti-freeze. This can cause severe personal injury, death or substantial property damage. If a backflow preventer, pressure reducing valve or check valve is in cold water supply, install an expansion tank on cold water supply line (see Figure 4) to prevent normal thermal expansion from repeatedly forcing open the T&P relief valve. T&P relief valve's discharge piping must be directed so that hot water flows away from all Figure 5. MCH Schematic.

Page 6 LAAS HEATING SSTEMS WALL THEMOSTAT (FIELD SUPPLIED) P W A TEMINAL STIP BL B TANK AQUASTAT NC 24V COM SEN COM NO TANSFOME 24V G 115V 1 4 ZONE PUMP ELA BK W BK HOT 115/60HZ POWE SUPPL NEUTAL GOUNDING CONDUCTO SENSO AQUASTAT (OPTIONAL) HIGH LIMIT O P 5 2 6 3 BK B PUMP (FIELD SUPPLIED) W BK - BLACK W - WHITE - ED - ELLOW BL - BLUE B - BOWN O - OANGE P - PUPLE G - GEEN BL/ - BLUE/ELLOW STIPE B/ - BOWN/ELLOW STIPE 115V-FACTO WIED 115V-FIELD WIED 24V-FACTO WIED 24V-FIELD WIED IF AN OF THE OIGINAL WIE (AS SUPPLIED WITH THE APPLIANCE) MUST BE EPLACED, IT MUST BE EPLACED WITH APPLIANCE WIING MATEIAL SUITABLE FO 105 DEGEES C O ITS EQUIVALENT Figure 6. Wiring Diagram. PESSUE SWITCH OLL-OUT SAFET SWITCH P BL GAS VALVE MOLEX 4. When water discharges from the faucet, close it. Check for system leaks and repair if necessary. Filling and connecting boiler pipes: Consult the JV boiler manual, Document 1080. Caution Never use water heater/boiler unless it is completely filled with water. 2D. Wiring Priority System: Under this wiring the storage tank will be supplied before space heating. This will insure that it gets adequate hot water flow from the boiler to maintain a fully rated delivery of domestic hot water. Caution In this priority mode, any demand for space heating is postponed until the storage water tank has reached set temperature. This delay in supplying the space heating zones is usually not noticed by the inhabitants of the living spaces. However, in the event of certain storage water tank malfunctions, space heating could be delayed indefinitely. If undetected and un-corrected, freezing damage to piping could result. BL O P BL 5 5 1 4 2 6 3 1 4 2 6 3 TANK PUMP ELA INDUCE MOTO ELA BK B B W INDUCE TANK PUMP MODEL MCH H2021000A WANING Electrical shock can cause severe personal injury or death. Disconnect power supply to the boiler before doing any electrical work. Electrical Connection (see Figures 5 and 6). 1. emove the two screws attaching the front cover of the control box. 2. There are six wires coiled in the area on the right side of the control box, supplied with wire nuts: 2 black wires twisted together, 3 white wires twisted together, and a brown wire. 3. Follow the schematics in Figures 5 and 6. emove the wire nut from the two black wires, and connect the hot lead from a 115 volt power supply to both wires. Secure the three wires in the wire nut. 4. The three white, neutral wires should be joined to the other neutral lead coming from the 115 volt power supply, and the neutral lead coming from the pump (space heating). 5. The brown wire attaches to the hot side of the space heating pump. W

Mini-Combo id Page 7 115 Volts Supply Sequence of Operation Transformer Tank Stat (common) Domestic Demand (N.C.) Heating Demand (N.O.) Tank Pump (energized) Heating Pump (energized) High Limit Switch Inducer Energized Fan Proving Switch Flame oll-out Safety Switch Main Gas Valve (energized) Boiler On Figure 7. Sequence of Operation.

Page 8 LAAS HEATING SSTEMS Figure 8. Parts Identification.

Mini-Combo id Page 9 # Qty Part # Description 1 1 20085700 Weldment, Panel, Base 2 1 20085600 Weldment, Panel, Top 3 1 20086300 Weldment, Panel, Door 4 1 20086400 Panel, Side, ight 5 1 20127900 Weldment, Panel, Side, Left 6 1 20085900 Panel, ear 7 1 20086500 Panel, Access 8 1 20084000 Bracket, Mounting, Left 9 4 20085400 Bracket, Support, Tank 10 2 P2019200 Cross, Black Iron, 1¼" NPT 11 4 P2014800 Fitting, Brass Compression, 7/8" OD x ¾" 12 1 A2085600 Valve, Check, ¾" NPT 13 7.2ft P2015000 Tubing, Copper, Type L, 7 /8" OD 14 1 A2085700 Valve, Drain, Tank, ¾" NPT 15 1 E0205000 Temperature Control, Electronic 16 1 A2085400 Valve, elief, Temp & Pressure 17 1 A2085301 30 Gal. Water Tank, Double Wall HX 1 A2085300 30 Gal. Water Tank, Single Wall HX 18 2 20087300 Door Latch Assembly 19 1 A0066500 Pump, Circulator 20 1 A2086600 Valve, Check, 1¼" NPT 21 1 A2087600 Handle, Door 22 2 A2086700 Flange, Pump, ¾" NPT 23 1 A2085900 Well, Immersion, ¾" NPT 24 1 A2000400 Gauge, Pressure/Temperature 25 1 A2000600 Gauge, Temperature 26 1 20084001 Bracket, Mounting, ight 27 1 E2103100 Sensor

Page 10 LAAS HEATING SSTEMS

Mini-Combo id Page 11

H2100200B Waterpik Technologies, Inc. 6000 Condor Drive, Moorpark, CA 93021 805.529.2000 FAX 805.529.5934 20 Industrial Way, ochester, NH 03867 603.335.6300 FAX 603.335.3355 480 S. Service oad West, Oakville, Ontario, Canada L6K 2H4 905.844.8233 FAX 905.844.2635 www.laars.com Litho in U.S.A. Laars Heating Systems 0005 Document 2101B