Quest Power Electric Heat EHS 62 Pro

Similar documents
Quest Power Electric Heat EHS 31 Pro

Owner s Manual Phoenix FireBird

Quest PowerHeat HFC 100 Pro

Owner s Manual Phoenix Aquadry TX 200

Phoenix AirMAX - Radial Air Mover

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest Dry 105, 155, and 205 Dual

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest 105, Dry155, and 205 Dual

Owner s Manual Phoenix Arctic Max

Owner s Manual Hydro-X Vacuum Pac

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Owner s Manual Phoenix 250 MAX

DRY 150 Quest PowerDry 1300

OmniDry 2.9 Amp Centrifugal Air Mover

INSTALLER S & OWNER S MANUAL

Owner s Manual Phoenix 200HT

Owner s Manual Phoenix 250 MAX

INSTALLER S & OWNER S MANUAL

Quest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions

Owner s Manual Ultimate 340

Energedry Elite Eliminator Pest Control Electric Heat System

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R200 LGR Dehumidifier. Installation, Operation & Service Instructions

IMPORTANT SAFEGUARDS IMPORTANT INSTRUCTIONS PRECISION HEAT TM DIGITAL HEATER FAN READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT SAFEGUARDS IMPORTANT INSTRUCTIONS DIGITAL LOW PROFILE HEATER READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT SAFEGUARDS IMPORTANT INSTRUCTIONS DIGITAL CERAMIC HEATER READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Owner s Manual Phoenix 300

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

READ AND SAVE THESE INSTRUCTIONS

Read and Save These Instructions

ELECTRIC FIREPLACE OWNER S MANUAL

IMPORTANT SAFETY INFORMATION

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

ELECTRIC STOVE HEATER Models: FS2213B

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions

Energedry Eliminator 52K

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

DRY 150 Quest PowerDry 1300

BLT-999W-2 Item # 60757

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Owner s Manual Phoenix R125 LGR Dehumidifier

Owner s Manual Phoenix 200 MAX

Operation and warranty Manual

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

ELECTRIC FLAT PANEL FIREPLACE HEATER

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Radial 8 Heater For Professional use only

Owner s Manual HI-E Dry Vehere

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

Owner s Manual Phoenix Dry Max LGR Dehumidifier

User s Manual & Operating Instructions

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

AH-600 Baseboard Heater

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

HI Industrial Utility Heater HI Soleus Air International

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

E1.5 ELECTRIC FAN HEATER

IMPORTANT SAFETY INFORMATION:

Installation and Maintenance Manual Please retain this manual for future reference.

Installation, Operation and Maintenance Instructions. Read and Save These Instructions

USER GUIDE. Metal Ceramic Heater NS-HTMCSL6. Before using your new product, please read these instructions to prevent any damage.

Electric Garage Heater

AH-400 Oil Filled Personal Heater

AH-400 Oil Filled Personal Heater

40E ELECTRIC FAN HEATER

Low Profile. Baseboard Heater

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

IMPORTANT SAFETY INFORMATION:

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT SAFETY INFORMATION:

Motion Sensor Oscillating Heater with Digital Control

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

INFRARED ZONE HEATING SYSTEM

AH-450B Oil-Filled Radiator Heater OWNERS MANUAL

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

18E ELECTRIC FAN HEATER

IMPORTANT SAFETY INFORMATION:

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

IMPORTANT INSTRUCTIONS

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

NO VENTING REQUIRED 120V AC;

Electric Fireplace Instruction Manual

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

The Family Ceramic Heater

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

GALE FORCE VAF-16R. Ventilation Manual

40E ELECTRIC FAN HEATER

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

Energedry Eliminator. Operations Manual. Electric Heat Drying System. K & J Representatives, LLC Fax

Installation, Operation and Maintenance Instructions

FLCH4R Garage and Utility Electric Heater

CABINET INFRARED HEATER

Transcription:

Quest DRY Power 150 Electric Heat EHS 62 Pro Read and Save These Instructions The Quest Power Electric Heat EHS 62 Pro portable, heavy duty electric heater features multiple power receptacles for connection to common 120VAC outlets, 240VAC range/dryer type outlets, or both. The Power Electric Heat EHS 62 Pro can produce up to 62,000 BTU s of clean, safe heat at 750 CFM. Internal temperature cutouts prevent the Power Electric Heat EHS 62 Pro from overheating the space, while the Power Electric Heat EHS 62 Pro s remote thermostat provides a means to control the heat up to 25 away. Quest Power Electric Heat EHS 62 Pro: Listed by ETL to UL Safety Standards 30/50 Amp Operation at 240VAC (18,000 BTU / 32,000 BTU) 15 Amp Operation at 120VAC up to 6 independent circuits (30,000 BTU) Two 8 Power Cords (1 dryer, 1 range) included Remote Thermostat with 25 connecting wire included Standard MERV-11 air filter included Multiple ducting options 12 Inlet, 12 Outlet Stainless Steel Cabinet Quest Power Electric Heat EHS 62 Pro PN 4030490 Specifications subject to change without notice. 1 4201 Lien Rd. Phone 608-237-8400 Madison, WI 53704 Toll-Free TS-764 06/14

Table of Contents Introduction... 1 1. Specifications... 4 2. Operation... 4 2.1 Transporting... 4 2.2 Electrical Requirements... 4 2.3 Ducting... 5 2.4 Control Panel... 6 2.5 Hour Meter... 6 2.6 Remote Thermostat Connection... 6 3. Maintenance... 7 3.1 Air Filter... 7 4. Service... 7 4.1 Technical Description... 7 4.2 Troubleshooting... 7 5. Options and Accessories... 8 6. Wiring Diagram... 8 7. Service Parts... 9 Warranty... 10 Serial No. Purchase Date / / Dealer s Name Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Quest Power Electric Heat EHS 62 Pro. 2

Unit Intended for INDOOR USE ONLY; DO NOT USE OUTDOORS. Device is HOT when in use. To prevent burns, avoid skin contact with hot surfaces. Use handle when moving device. Maintain 36 minimum clearance between device outlet and any combustible materials such as furniture, pillows, bedding, papers, clothes and curtains. Keep such items away from sides and rear of device. Extreme caution is necessary when device is used by or near children or invalids and whenever device is left operating unattended. Always unplug unit when not in use. DO NOT OPERATE with damaged cord, plug, or after unit malfunctions, has been dropped or damaged in any manner. Return to authorized service facility for adjustment or repair. Device not intended for use directly in an area where it may fall into a bathtub or other water container. DO NOT run cord under carpeting or other floor covering. Arrange cord away from traffic area and where it will not be tripped over. To disconnect device, turn controls off, then remove plug from outlet. Connect ONLY to properly grounded outlets. DO NOT insert or allow foreign objects to enter any ventilation or exhaust openings as this may cause an ELECTRIC SHOCK or FIRE, or damage the heater. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked. Device has hot and arcing or sparking parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored. Use device only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. Avoid use of an extension cord for 240V service because the extension cord may overheat and cause a risk of fire. However, if an extension cord is required, the cord shall be No. 6 AWG minimum size and rated not less than 9600 Watts. Cords used for 120V service shall be No. 12 AWG minimum size rated not less than 1440 Watts. 3

1 Specifications Part No. 4030490 Power Blower Circuit: 2 Amp at 120VAC 60Hz, 1 Phase 220/240VAC 60Hz, 1 Phase Heater Circuit: User Selectable 30/50 Amp Operation 30 Amp = 30 F temperature rise: 18,000 BTU 50 Amp = 54 F temperature rise: 32,000 BTU 120VAC 60Hz, 1 Phase Heater Circuits (up to 6): 12 Amp / circuit = 9 F temperature rise/ circuit: 5,000 BTU Maximum Heat: 62,000 BTU with 80 F Temperature Rise at 750CFM Blower 750 CFM Filters Pleated Media MERV-11 Duct Options Inlet 12 Flex-Duct Outlet 12 Flex-Duct Warranty 1 year 100% of Parts and Labor Dimensions Unit Shipping Width 20.25 27.5 Height 40 45.25 Depth 21.4 25.5 Weight 105 lb 130 lb 2 Operation 2.1 Transporting The Quest Power Electric Heat EHS 62 Pro must always be upright when transported by vehicle. It may be tipped onto its handle and back for loading and moving by hand. The Quest Power Electric Heat EHS 62 Pro features a high-impact plastic skid plate which protects the unit while navigating obstacles such as curbs, stairways, and while loading into vehicles. 2.2 Electrical Requirements The Quest Power Electric Heat EHS 62 Pro requires a 120VAC outlet to power the onboard blower and control circuit. Heating elements are separately powered by additional cords and receptacles. For the 240VAC heating elements, the Power Electric Heat EHS 62 Pro is fitted with a 240VAC grounded receptacle. When used with the appropriate cord, it provides a ground connection through the cord to the heater to protect the operator from electric shock. The Quest Power Electric Heat EHS 62 Pro comes 4

equipped with two 8 long cords for connection to grounded residential range and dryer receptacles. These cords have plugs as shown. Note that no adapters are available for these blade configurations, and none should be used. 120VAC heating elements each require cord connection to appropriate receptacles rated at 15A or more. One cord and receptacle are required per heating element. Power cords should be appropriately sized (typically #12 minimum). Each heater cord should have a three-blade grounding-type plug as shown. An adapter is available for connecting to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available. NEMA 14-30 NEMA 14-50 Plug Adapter Outlet Grounding Pin Grounding Means Metal Screw 2.3 Ducting The Quest Power Electric Heat EHS 62 Pro can be ducted at the inlet, the outlet or both. The Power Electric Heat EHS 62 Pro lid and outlet adapter are designed to accommodate 12 flexible duct. When selecting flexible ducting keep in mind anticipated outlet temperatures. Air temperature increase is typically 50 to 80 degrees F. Adding ducting decreases airflow which can increase outlet temperatures by up to 40 additional degrees F. 5

2.4 Control Panel Master Power Switch: The Master Power Switch located on the left side of the control panel can be used to turn the unit ON, OFF, or set the unit to be controlled by an external thermostat. When set to ON, the Fury will energize the blower and close the heater contactors continuously. Depending on the connected power sources, the corresponding heater elements will be energized. In this mode, the Fury is limited to 140 F incoming air temperature by an internal thermostat. When set to THERMOSTAT, the blower will run continuously, but the heating contactors will only energize when the thermostat terminals (located under the lid) are connected by a switch, remote thermostat, timer, etc. Heat ON/OFF Switches: These switches individually control the 120VAC/1500W heating elements. Each switch connects and disconnects the power from the receptacle below it. These switches are lighted to indicate when power is connected and the corresponding heating element is on. 2.5 Hour Meter The digital hour meter measures the cumulative time that the unit is turned on to tenths of an hour. It stores and displays the total when the unit is unplugged. It resets to zero after 99,999.9 hours of operation. 2.6 Remote Thermostat Connection To connect the included remote thermostat, first locate the thermostat terminals under the lid of the Power Electric Heat EHS 62 Pro. There are 2 spring loaded terminals for connecting the thermostat wiring. Connect one wire to each terminal. If the Power Electric Heat EHS 62 Pro is placed inside the space to be heated, place the thermostat on top of the unit. For applications where the Power Electric Heat EHS 62 Pro is placed outside the space to be heated (e.g. ducting heat into a chamber), the 25 cord allows you to place the thermostat inside the heated space. In addition to the included thermostat, any dry-contact switch or other type of control that connects the terminals together will cause the heating elements to run. The thermostat circuit is low voltage (24VAC). DO NOT CONNECT POWER TO THE THERMOSTAT TERMINALS. Always press terminal levers to release spring pressure before disconnecting thermostat wiring. Failure to do so will lead to excessive wear on spring loaded terminal connector. 6

3 Maintenance 3.1 Air Filter The Quest Power Electric Heat EHS 62 Pro is equipped with a pleated fabric air filter that must be checked regularly. The standard filter is a MERV-11 high efficiency filter. Operating the Power Electric Heat EHS 62 Pro with a dirty or obstructed filter will reduce airflow eventually causing the heating element to shut off. Installing a clean filter or removing the obstruction to restore airflow will allow the heating element to operate again. The filter can generally be vacuumed clean several times before needing replacement. Replacement filters can be ordered from the factory or purchased locally if available. WARNING: DO NOT operate the unit without the filter or with a less effective filter as the heating coils inside the unit could become clogged and require disassembly to clean. 4 Service WARNING: Servicing the Quest Power Electric Heat EHS 62 Pro with its high voltage circuitry presents a health hazard which could result in death, serious bodily injury, and/or property damage. Only qualified service people should service this unit. Do not operate the unit without the front panel in place. High voltage is present, heater burnout may result. 4.1 Technical Description The Quest Power Electric Heat EHS 62 Pro uses a wound nichrome heating element to provide multiple heat settings depending on application requirements or available power. The heating elements are operated by a 24VAC control circuit and a number of relays and contactors. For safety, there is an air pressure switch that will shut the heating elements off or prevent the heating elements from coming on if airflow is restricted at either the inlet or the outlet. An additional safety switch limits the incoming air temperature to approxmiately 140 F. This switch shuts off the heating elements and automatically resets when the temperature falls to approximately 130 F. 4.2 Troubleshooting NOTE: High Power setting requires an external 50A circuit. Connecting to a 30A circuit with unit set to High Power will result in an external circuit breaker trip. Low voltage heating circuits require dedicated 15A minimum service for each circuit (up to 6 total). Blower not running 1. Unit unplugged, no power to outlet 2. Power Switch not working 3. Wiring fault inside device 4. Defective blower or blower capacitor 7

Blower running but no heat 1. Power switch is set to Thermostat and no thermostat is connected, or thermostat is open 2. 24VAC Transformer circuit breaker tripped 3. Airflow restricted at inlet or outlet 4. High temperature limit reached (140 F) 5. Heating contactor(s) not operating 6. Wiring fault inside device 7. Defective heating element, pressure switch, or temperature limit switch 5 Options and Accessories 4024750 12 x 25 Intake Flex Duct 4024969 16 x 20 x 2 Pleated Media MERV-8 4021475 16 x 20 x 2 Standard Pleated Media MERV-11 4027326 25 240V Cord Kit 4031045 50 240V Cord Kit 4031046 75 240V Cord Kit 4031047 100 240V Cord Kit 4030978 120V Cord Kit 4030115 Reed LM 8000 Multi-Function Meter 4027322 Remote Thermostat 6 Wiring Diagram L1 120 VAC 60HZ, 1 PH L2 L1 240 VAC 60HZ, 1 PH L2 24V TRANSFORMER CONTACTOR COIL # 4 2880 W ELEMENT (19.4 OHMS) CONTACTOR COIL # 3 CONTACTOR #2 2880 W ELEMENT (19.4 OHMS) OPTIONAL THERMOSTAT CONTACTOR COIL # 2 CONTACTOR #1 3840 W ELEMENT (14.5 OHMS) CONTACTOR COIL # 1 L1 120 VAC 60HZ, 1 PH N PRESSURE SWITC H 140 THERMAL CUT-OUT HI /LOW POWER SWITC H MASTER POWER SWITC H BLUE BLOWER BROWN 15 mf BLAC K CONTACTOR #3 & #4 1500 W ELEMENT (9.3 OHMS) HOUR METER X6 TOTAL CIRCUITS 8

7 Service Parts Item Description QTY Part No. 1 Heat HIGH/LOW Switch 1 4027330 2 Master Power Switch 1 4030941 3 Hour Meter 1 4028795 4 Flanged 50A Inlet 1 4027308 5 Skidplate 1 4025691 6 Wheel 2 4025676 7 Foot 2 4024073 8 Flanged 120V Inlet 6 4027258 9 Heat ON/OFF Switches 6 4021822 10 Pressure Switch 1 4029187 11 Thermostat 1 4030614 12 15mf Capacitor 1 4031242 13 Single Pole Contactor 2 4031101 14 3 Pole Contactor 2 4030945 15 24VAC Transformer 1 4031466 16 Heating Elements 1500W 6 4030617 2880W 2 4030618 3840W 1 4030619 17 Blower 1 4029455 Remote Thermostat (not shown) 1 4027322 1 17 9 2 10 3 16 4 8 5 11 15 12 6 7 13 14 9

Warrantor: Therma-Stor LLC 4201 Lien Rd Madison, WI 53704 Telephone: Quest Power Electric Heat EHS 62 Pro Limited Warranty Who Is Covered: This warranty extends only to the original end-user of the Quest Power Electric Heat EHS 62 Pro, and may not be assigned or transferred. Year One: Therma-Stor LLC warrants that, for one (1) year the Quest Power Electric Heat EHS 62 Pro will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace the defective part(s), free of any charge. End-User Responsibilities: Warranty service must be performed by a Servicer authorized by Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-Stor Service Department, which will then arrange for covered warranty service. Warranty service will be performed during normal working hours. The end-user must present proof of purchase (lease) upon re, by use of the warranty card or other reasonable and reliable means. The end-user is responsible for normal care. This warranty does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC s reasonable control. Limitation and Exclusions: If any Quest Power Electric Heat EHS 62 Pro part is repaired or replaced, the new part shall be warranted for only the remainder of the original warranty period applicable thereto (but all warranty periods will be extended by the period of time, if any, that the Quest Power Electric Heat EHS 62 Pro is out of service while awaiting covered warranty service). UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Quest Power Electric Heat EHS 62 Pro OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY Quest Power Electric Heat EHS 62 Pro OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY. Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the exclusion or limitation of incidental or consequential damages, so one or both of these limitations may not apply to you. Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 10