Flame detector. The QRA4.U is for use with the following types of burner control:

Similar documents
Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. Building Technologies Division Infrastructure & Cities Sector

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

Flame Safeguards LFE10. Building Technologies HVAC Products

Infrared Flame Detectors

Flame Safeguards LFE10. Building Technologies HVAC Products

RAR... Photocell Detectors. Building Technologies Division

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Infrared Flame Detectors

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

UV Flame Supervision System

LAE10 LFE10. Use. Series 02

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Blue-flame Detectors

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

C Note! LGI16... Burner Controls. Building Technologies

Oil Burner Controls LOA3... Building Technologies HVAC Products

LGA... Gas Burner Controls. Building Technologies Division

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Basic unit with integrated air-fuel ratio control for forced draft burners

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Oil Burner Controls LOA3... Building Technologies Division

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

Heating Element. Building Technologies HVAC Products

Burner controls. Building Technologies HVAC Products

Burner Management System

LFL Series Burner Flame Safeguard Control

UV - flame detector dual fuel burners for intermittent burner operations

Burner Management System

Burner Management System

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Burner Controls. Building Technologies HVAC Products

Gas Burner Controls. Building Technologies HVAC Products

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Use. The burner controls are certified to EN 230 and EN 298.

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

for relative humidity and temperature

for relative humidity and temperature with calibration certificates

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room Temperature Sensor

Silicon UVAB Sensor E xxx

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

for relative humidity and temperature

FLV 40 UV Flame Detector

Silicon Pyranometer GSM xx

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Forced draught gas burner

EUROBOX SERIES TYPES CM... SM... MM...

Product Range Overview

COMPACT FLAME CONTROLLER CFC 100

Chemical Processes in the Combustion

Room Air Quality Sensors

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

RIELLO 40 GS/M SERIES

This document is a preview generated by EVS

Operating Manual MS220KA and MSR220KA

Room Temperature Sensors

MBCE-110/230UV Flame Sensor Module

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Use. Functions. Key function. Other functions

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Advanced Ultraviolet Burner Controller

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Building Technologies Division

AUR300C. Advanced Ultraviolet Burner Controller

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

BENSON LINEAR RADIANT TUBE

LOW NOx MODULATING GAS BURNERS

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

EUROFLAT SERIES TYPES C... S... M...

Building Technologies Division

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Gas cylinder scale Model GCS-1

FIREYE FLAME SCANNERS

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Old documentation - Only for your information! Product is not available anymore!

Eclipse 90 UV Scanner Model A Version 1

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Transcription:

7 711 Flame detector QRA4.U UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate the flame detectors in their products. Use The flame detector is used for the supervision of gas flames, yellow- or blue-burning oil flames and for ignition spark proving in intermittent operation. The QRA4.U is for use with the following types of burner control: Burner control LFL... LFE1... LFE10... LGB2... / LGB4... with AGQ1... LME21...A2 / LME22...A2 with AGQ3... LME39...A2 with AGQ3... LME41...A2 / LME44...A2 with AGQ3... LME7... LMV2 / LMV3 LMV5... with AGQ1... Data Sheet N7451 N7461 N7781 N7435 N7101 N7106 N7101 N7105 N7541 N7550 20.07.2009 HVAC Products

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the flame detector! Condensation, formation of ice and ingress of water are not permitted! All activities (mounting, installation and service work, etc.) must be performed by qualified personnel Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard Ensure protection against electric shock hazard by providing adequate protection for the connection terminals Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state Halogen lamps, welding equipment, special lamps or ignition sparks may produce sufficient radiation for the detector s UV cell to ignite. X-rays and gamma radiation can also generate erroneous flame signals Fall or shock can adversely affect the safety functions. Such detectors must not be put into operation, even if they do not exhibit any damage Mounting notes Ensure that the relevant national safety regulations are complied with Installation notes Always run the high-voltage ignition cables separate while observing the greatest possible distance to the detector and to other cables Electrical connection of the flame detector It is important to achieve practically disturbance- and loss-free signal transmission: Never run the detector cable together with other cables Line capacitance reduces the magnitude of the flame signal Use a separate cable Observe the permissible lengths of the detector cable (refer to «Technical data» of burner control used) The connecting wires must be run through protective tubing (made of plastic or earthed metal) 2/6

Commissioning notes Trouble-free burner operation is ensured only when the intensity of UV radiation at the detector s location is high enough for the detector s UV cell to ignite during each half wave. The intensity of UV radiation at the detector s location is checked by measuring the detector current (refer to Data Sheet of the respective burner control) Measuring circuit for QRA4.U weiß rot Legend 1) Connection of microammeter across adapter AGQ1... / AGQ2... / AGQ3... and flame detector A Incidence of radiation M Microammeter (DC), internal resistance 5,000 Ω C Electrolytic capacitor 100...470 µf, DC 10...25 V Standards and certificates Only in connection with the burner control Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Directive for gas appliances - Low-voltage directive 2004/108/EC 90/396/EEC 2006/95/EC ISO 9001: 2000 Cert. 00739 ISO 14001: 2004 Cert. 38233 Service notes Disposal notes Mechanical design Flame detector QRA4.U The UV cell is glued inside the housing and cannot be removed. When the end of the UV cell s service life is reached, the complete flame detector must be replaced. The flame detector contains electrical and electronic components and must not be disposed of together with domestic waste. Local and currently valid legislation must be observed. UV flame detector for frontal illumination. Housing made of aluminium, with ¾ -14NPSM connecting thread for fitting the detector to the burner or boiler. Connecting wires of about 1.8 m length for the electrical connection. ½ -14NPSM thread for a fitting, required for the connection of a Menzel tube for protecting the connecting wires (½ conduit). 3/6

Accessories Product no. Designation Mounting coupling Adapter of QRA4.U-NPSM thread for a European pipe thread. QRA4.U 7711z01/0509 (Spare part) Heat insulating piece between QRA4.U and mounting coupling. Heat insulating piece QRA4.U 7711z02e/0709 Heat insulating piece 4/6

Technical data General detector data Average life of UV cell Perm. combustion chamber pressure Degree of protection Mounting position Weight Device safety class Length of connecting wires Conduit for protective sleeve (Menzel sleeve) Approx. 10,000 hours at max. +50 C, higher ambient temperatures reduce considerably the cell s life Max. 150 mbar IP54 (to be ensured through mounting) Optional Approx. 180 g II (double-insulated) Approx. 1,800 mm ½ -14NPSM thread Environmental conditions Storage DIN EN 60721-3-1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -20...60 C Humidity <95% r.h. Transport DIN EN 60721-3-2 Climatic conditions Class 2K3 Mechanical conditions Class 2M2 Temperature range -20...60 C Humidity <95% r.h. Operation Climatic conditions Mechanical conditions Temperature range Humidity DIN EN 60721-3-3 Class 3K5 Class 3M5-20...60 C <95% r.h. Function With this type of flame supervision, the UV radiation emitted by gas or oil flames is used to generate the flame signal. The radiation detector is a UV-sensitive cell with 2 electrodes, which ignite when illuminated with radiation in the 190...270 nm range of the spectrum, thereby triggering a current in the flame detector circuit. The UV cell does not respond to glowing firebrick in the combustion chamber or to daylight. 5/6

Dimensions Dimensions in mm Flame detector QRA4.U 30.5 35 7711m01e/0503 103 19 M1:1 Internally threaded 3/4" - 14 NPSM Internally threaded 1/2" - 14 NPSM Mounting coupling 69.9 ±0.5 3/4" - 14 NPSM Pipe thread ISO 228/1-G1 SW 36 7711m02e/0709 SW 21 2009 Siemens HVAC Products GmbH 6/6 Subject to change!