Applying Neural Network Technology to the Next Generation Flame Detector

Similar documents
Flame Detection Jon Sarfas

FM Approved Fire & Gas Detection System

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Model TL104 MANTL104. Test Lamp for Flame Detection

MSA s Guide to Selecting the Right Flame Detector for Your Application

SharpEye Flame Detector Selection Guide

GENERAL MONITORS. Protection for life. Product Guide. Total Solution Provider for Gas and Flame Detection

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

CCTV, HOW DOES IT WORK?

High Temperature Remote Gas Calibrator

LEARNING SPECIAL HAZARD DETECTION TYPES

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Dräger Flame 2500 Flame Detection

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

The SharpEye 40/40I (IR3) Flame Detection

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

The SharpEye 40/40M (Multi IR) Flame Detection

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

Model 3300 Technical Support and Installation Manual

talentum Flame detection across the spectrum Range Brochure

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Conspec - Why use our Flame Detectors

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Talentum - Why use our Flame Detectors?

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Basic Vehicle Fire Protection Manual

F&G detection system for LNG plants

Dräger Flame 2100 Flame Detection

FlameGard 5 UV/IR HART

FlameGard 5 MSIR HART

The SharpEye 40/40I (IR3) Flame Detection

Model FMD. Field Mounted Display Module

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

Industrial Grade Gas Detection

MSA Fixed Gas & Flame Detection for the Automotive Industry

FIRE IR SENSOR Flame Detection

IFD-E Flame Detector User Manual

MODEL FL3102. Digital Frequency Infra-Red (DFIR) Flame Detector MANFL3102. Instruction Manual 07-08

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Fire Detection System: An Overview

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

HigH Performance Low cost flame Detection. Courtesy of Foster + Partners. The New 20/20M MINI FLAME DETECTOR SERIES

IFD-E Flame Detector User Manual

The SharpEye 40/40R (IR) Flame Detection

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

An FT-NIR Primer. NR800-A-006

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Guidance on Video Smoke Detection Technology (VSD)

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Meeting NFPA standards for

Dräger Flame 2500 (IR3) Flame Detection

INTREPID Perimeter Intrusion Detection System

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

Dräger Flame 2700 (Multi-IR) Flame Detection

Flame Detector User Manual

APPLICATION OF VISUAL FLAME DETECTION

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Talentum Flame Detector User Guide

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

RLDS - Remote LEAK DETECTION SYSTEM

Recalibrate the way you look at gas detection

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Chapter 2 Background. 2.1 VID Technology

Fire & Security Products. Siemens Flame Detector a highlight in detection. technology.

Sieger fixed gas detection. Fixed protection from hazardous gas

Model 2602A. Zero Two Series Control for Hydrogen Sulfide Gas Applications

Flexible Air-sampling Smoke Detection

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

Contents. 1. Fire Detection motivation. 2. SharpEye Detector Range. 3. Detector Accessories. 4. How to Specify & Locate Detectors

Smart Fire Prevention

ADPRO PRO Passive Infrared Detector. Webinar November Ben Klösen, PLM

WG Buried Fibre Cable Long Perimeter Detection System

Dräger Flame 5000 Flame Detection

Fixed Gas & Flame Detection International Product Range Overview

Presented By. BEI Security

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Fire protection in hazardous locations:

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Fire Detection systems. UniVario industrial fire detectors for every job

ommercial and military aircraft MRO operations play a huge role in keeping modern aircraft in service by taking on new tasks and

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Danfoss gas detection unit Type GD Heavy Duty

HART XL High Sensitivity Smoke Detection

Maxline 2 Thermal Imaging Solutions for Manufacturing

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

HYDROCARBONENGINEERING June June 2015

FAAST. Fire Alarm Aspirating Sensing Technology

Dräger Flame 5000 Flame Detection

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Design Manual Installation Operation Maintenance

Transcription:

Applying Neural Network Technology to the Next Generation Flame Detector Breakthrough Neural Network Intelligence for Improved False Alarm Immunity

www.generalmonitors.com

Innovative Technology for Superior False Alarm Immunity ARDEM ANTABIAN, Product Manager SHANKAR BALIGA, Group Manager, Sensors JAVID HUSEYNOV, Senior Software Engineer Accurate and reliable industrial flame monitoring has detection requirements, however, they are prone to generate false alarms if exposed to adverse environmental conditions such as reflected light, welding, hot piping, movement of human operators, machinery, and others. always represented a technical challenge. The main flame monitoring concern lies in the requirement to differentiate spectral radiation emitted by flames from that of background radiation, which is always present in the industrial environment. Insufficient differentiation of flames from background The development of Neural Network Technology (NNT) for multi-spectral optical flame detectors by General Monitors helps to resolve the problems described above. NNT is based on artificial neural networks (ANN), mathematical models of biological sources typically causes the highly undesirable condition of false alarm. When a false alarm condition occurs, it activates automated fire suppression equipment, causes operational Insufficient differentiation of flames from background sources typically causes the highly undesirable condition of false alarm. neurons in the human brain, which establish correlation between given signal patterns and target conditions. Combined with a multispectral optical sensor and implemented in software, neural interrupts, consumes extinguishing materials, and requires resolution of the alarm condition, which can include a network serves as an adaptive and intuitive decision mechanism with boundless optimization capability. complete system shutdown and restart. Until recently, the state-of-the-art in optical flame detection was based on multi-spectral detection integrated with an expert signal processing system. This expert system is typically based on a fixed set of conditions derived from the spectral analysis of a selected group of flames and programmed into computer logic. With proper installation, these types of instruments fulfill basic flame In the past decade, ANN has become a proven design technology applied to diverse industries such as automotive, aerospace, finance and industrial controls. In application to flame detection systems, the ability of neural networks to classify information from optical sensors contributes to increased flame detection range, greater field of view, and increased false alarm immunity in various adverse environments. www.generalmonitors.com

institutional facilities, require continuous flame monitoring equipment to prevent catastrophic fires that endanger employees, equipment, infrastructure and surrounding communities. This ultimately helps plant managers, engineers and technicians to reduce operating costs by providing superior performance and reliable flame detection to protect lives. With a next-generation multi-spectral infrared flame sensor that incorporates neural network technology, the new FL4000 Intelligent Multi-Spectral IR Flame Detection System from General Monitors offers the industry a new standard for performance, reliability and value that gives process and plant engineers a potent new tool in protecting people, equipment and facilities from dangerous hydrocarbon flame sources. The FL4000 is the industry s first flame detection system to combine precision multi-spectral IR (MSIR) flame sensing technology with highly intelligent neural network processors. The result is a breakthrough flame detector that provides the industry s most reliable discrimination between actual flames and nuisance false alarm sources, such as arc welding, hot objects, reflected sunlight and more. Flame Detection Applications and Technologies Engineers in a wide range of hazardous process and manufacturing industries, as well as government and Typical Applications The range of potential flammable hazards is expansive and growing as materials and processes become more complex. Increasingly sophisticated flame sensing technologies with embedded intelligence are required to reliably detect the most common potential ignition sources: > Alcohols > Kerosene > LNG / LPG > Chemicals > Jet Fuels > Paper/ Wood > Diesel > Hydrogen > Textiles > Gasoline > n-heptane > Solvents Some of the most challenging industrial environments for flame detection include: > Automotive > Oil / Gas Refineries > Aerospace > Pharmaceuticals > Chemical Plants > Textiles > Power Generation > Warehouses > Food/ Beverage > Wood & Paper Plants > Oil / Gas Production > Oil/ Gas Distribution Flame Sensing Technologies There are five primary optical flame-sensing technologies in use today: ultraviolet (UV), ultraviolet / infrared (UV/ IR), dual infrared (IR 2 ), triple infrared (IR 3 ), and IR/Closed-Circuit Television (CCTV). They are all based on line-of-sight detection of radiation emitted in the UV and IR spectral bands by flames (please see Figure 1). Depending on the specific flame monitoring application and the requirements for detection range, field of view (FOV), response time and false alarm immunity to various sources, one of these technologies is selected. 2

Relative Energy Ultraviolet Visible Infrared Sun s energy reaching the earth 300 nm 400 nm 800 nm 2-5 µm W avelength Figure 1: Emission Energy Spectrum UV Technology UV detectors respond to radiation in the UV region of approximately 180-260 nanometers. UV flame detectors operate at relatively high speed with good sensitivity up to 50 feet from the flame source. These detectors are best suited for indoor use and are unaffected by sunlight (solar blind) and hot objects. They are, however, vulnerable to false alarms triggered by other UV sources such as: arc welding, lightning, halogen lamps and electrical sparks. Thick smoke and /or grease build-up on the sensor window can also cause failures due to attenuation of the incident UV radiation. Their cost is relatively low compared to other types of flame detectors. from the flame source, but are affected by thick smoke and grease deposits on the detector window. Cost is moderate as compared to other flame detector types. IR 2 and IR 3 Technologies Dual and triple IR flame detectors use multiple infrared spectral regions to further improve differentiation of flame sources from non-flame background radiation. Both types of IR flame detectors are well suited to locations where combustion sources produce particularly smoky fires. These flame detectors operate at moderate speed with a range of up to 200 feet from the flame source -- both indoors and outdoors. These instruments exhibit relatively high immunity to infrared radiation produced by arc welding, lightning, sunlight and other hot objects that might be encountered in industrial backgrounds. Their cost is high relative to other types of flame detectors. CCTV/IR 3 Technologies CCTV/ IR 3 flame detectors combine three IR sensors covering multiple infrared spectral regions with video cameras. These devices have the same benefits as IR3 detectors, but also include viewing capabilities. The addition of video allows operators to monitor areas remotely for fire and to checkout alarms prior to determining the best response. Their cost is higher relative to other flame detector types. UV/IR Technology When a UV optical sensor is integrated with an IR sensor, a dual band detector is created which is sensitive to both UV and IR radiation emitted by a flame. The combined UV/IR flame detector offers increased immunity over the UV detector. UV/ IR flame detectors, when combined with flicker discrimination circuitry, reduce the possibility of false alarms caused by arc welding, lightning, sunlight and hot objects. They operate at moderate speed, are suited for both indoor and outdoor use up to 50 feet The detection range of the infrared detectors is up to 200 feet from the flame source; however, the video camera coverage is typically less than the full infrared detection range. The operating temperature range for the video camera is narrower than for the IR3 detector array. Flame Detection Performance Requirements When configuring a flame detection system for a plant and evaluating the various flame detection technology alternatives available today on the market, the following www.generalmonitors.com

flame detector performance criteria should be considered relative to plant and regulatory requirements: > False Alarm Immunity > Operating Temperature Range > Detection Range > Communication Capabilities > Response Time > Self Diagnostics (COPM) > Field of View (FOV) False Alarm Immunity Once the performance requirements for a flame detector have been determined based on the assessment of potential combustion sources, the next important consideration is false alarm immunity. False alarms are more than a nuisance -- they are both a productivity and cost issue. It is essential that flame detectors discriminate between actual flames and radiation from sunlight, lightning, arc welding, hot objects and other non-flame sources. lost within a process batch or on a manufacturing line are real as well. Deliveries can be delayed and customers can be annoyed. Reliable discrimination between actual flames and ordinary environmental and normal plant activities is essential. Today s best UV /IR and IR3 detectors reduce the possibility of false alarms from typical environmental and plant sources. They do, however, have some well-known limitations and they are not foolproof by any means. Until now, plant engineers facing persistent false alarm problems have had to choose between accepting the cost of false alarms, changing the process or installing complex redundant flame detection systems at a high cost and with high maintenance requirements. There had to be a better solution to false alarms. From the perspective of productivity alone, a false alarm Detection Range and False alarms are more than a nuisance -- they are both a incident in most process Response Time productivity and cost issue. control and manufacturing The most basic performance criteria industries requires a system are detection range and the shut-down, probable evacuation and investigation. response time provided by the various flame detector Turning off and then re-starting a process control or manufacturing line may take anywhere from an hour to a whole shift or longer, especially if there are complex material, batching or quality requirements and /or environmental regulatory reporting requirements to consider. technologies. Depending on a specific plant application environment, each of the alternative flame detection technologies will recognize a flame to a maximum distance with a response time dependent on the sensing technology. The greater the distance and the shorter the time that a given flame sensing technology requires to When we think about productivity loss, we generally think about down time first and then the associated detect a flame, then the better the technology is in providing for advance flame warning. costs. False alarms drain labor productivity, and start with emergency responders and worker downtime. They often require investigations, written reports and discussions with regulatory agencies. Beyond the cost of labor, false alarms often trigger automated fire suppression systems: there is the replacement cost for extinguishing agents to consider, the costs of materials Field Of View (FOV) In addition to the detection range, the flame detector s field of view is typically proportional to the effective range of the detection distance. For example, the most common types of optical flame detectors have a 90 to 120 degree field of view. One might think that the wider 4

the FOV, the larger the area and volume of effective coverage. That is not necessarily the case, as a wider field of view can limit the maximum detection distance. For this reason, it is often necessary to place flame detectors at the corners of buildings or aligned in a series with overlapping coverage to achieve the required coverage. Self Diagnostics To meet the highest reliability standards, continuous optical path monitoring (COPM) diagnostics are often built into optical flame detectors, as is the case with those manufactured by General Monitors. The self-check procedure is designed to ensure that the optical path is clear, the temperature range. For example, flame detectors on Alaskan drilling rigs and North Sea offshore platforms must be able to withstand extremely low temperatures down to -40 F (-40 C). Oil and gas refining facilities in the Middle East and plants in the steel manufacturing industry have the opposite problem -- temperatures can reach to 176 F (80 C). In addition to extreme temperatures, flame detectors must support explosion-proof requirements, as well as operating in high humidity, harsh marine and other rugged environments. Communication Interface With advanced automation introducing increasingly detectors are functioning and additionally, the electronic circuitry is operational. Self-check routines are programmed into the flame detector s control circuitry to activate about once every minute. If the same fault occurs twice in a row, then a fault is indicated via the 0-20 ma output, and also initiated over the RS-485 serial communication link and processed via a MODBUS operator interface system to alert the maintenance staff. Operating Temperature Range In today s rigorous process and manufacturing industries, optical flame detectors need to operate over a wide intelligent process control and manufacturing systems, flame detectors not only need built-in embedded microprocessor-based intelligence -- they must also be able to communicate effectively. At a minimum, a 0-20 ma analog output is required for remote alarm and fault indication, as well as a RS-485 serial communication link that is MODBUS RTU compatible to network multiple detectors for the protection of larger areas and for communication with distributed (DCS), programmable logic (PLC) or PCbased control systems with operator interfaces for alarm conditions. www.generalmonitors.com

MSIR / NNT Multi-Spectral Infrared Flame Detection Using Neural Network Technology The popularity of optical IR flame detectors is dictated by the fixed emission wavelengths of hydrocarbon flames in the infrared spectrum, which can be separated from most non-flame sources and analyzed in various domains. Classical optical hydrocarbon flame detectors are based on an expert system, where analog signals are collected from the optical sensors, converted into digital format, processed, and an output decision is reported on the presence of flame or lack thereof. Although simple in appearance, the described model of flame detection becomes more complex when dealing with infrared data from real industrial environments. Infrared signals at flame emission wavelengths can be easily generated by a random motion, modulation of heated surfaces, hot air flow, arc welding, reflection off water surfaces, and other non-flame related environmental nuisance. Neural network technology (NNT) is used for analyzing data when mathematical relationships between the inputs and the outputs of a system are not easily derivable. We call the application of NNT with multiple infrared sensors at different wavelengths MSIR/NNT flame detection. Neural network processing involves training and classification phases. In the training phase, collected signals of interest are pre-processed using time and/or frequency analysis (Fourier Transform, Wavelets, etc.), and the resulting data is used for training the neural network with known targets. A recursive training algorithm generates a set of neuron connection weights to be used for classification. In the classification phase, the same form of pre-processing is applied to the signal for input into the trained neural network algorithm. After neural network processing, a decision is matched to a certain target. Optical flame detection manufacturers have attempted to resolve this problem by using multiple sensors, each at a different wavelength. In addition to wavelength discrimination via use of multiple sensors, most optical detectors measure the temporal characteristics of the signal, thereby analyzing the flame flicker properties. Various signal-processing techniques such as correlation, taking ratios, frequency analysis, periodicity check, and threshold crossing are used in industrial flame detection to discriminate flames from non-flames. SENSOR DATA COLLECTION IR 1 IR 2 IR 3 Analog-to-Digital Converter PROCESSING ALGORITHMS Signal Pre-Processing Neural Network Classification Outpost Post-Processing IR 4 SERIAL COMMUNICATIONS Ch. 1 Ch. 2 User MODBUS Processing INSTRUMENT OUTPUTS User MODBUS Output LEDs and Relays 0-20 ma Analog Output The apparent difficulty of linear separation of flames from non-flame sources drives the usage of more sensors at a variety of wavelengths. In practice, this solution is very laborious and difficult to implement as an expert system. So, there arises an interest in non-linear classification methods, in particular, artificial neural networks to discriminate between radiation from flame and nonflame sources of radiation. Figure 2: MSIR/NNT Flame Detector Model The advantage of neural network processing over expert systems is the fact that the increased ability of classification does not make the classification algorithm more complex. It only involves more training outside the classification system, on a separate workstation, to 6

improve constant connection weights. This advantage is particularly important in an embedded system, where performance of the application is dependent on a fixed set of neural network connection weights, and not on the complexity of algorithmic implementation. Signals coming from sensors at various spectral wavelengths are converted into digital format and pre-processed to extract time and frequency information. This information is then processed by the neural network algorithm, which classifies it as being emitted from flame or non-flame source. Further processing is applied to the output of the neural network to report the instrument s decision via MODBUS, 0-20 ma analog output, LEDs and relays. FL4000: General Monitors Next Generation Flame Detector The Model FL4000, General Monitors next generation flame detector, is designed to provide superior false alarm immunity while also providing the broadest detection coverage area. The horizontal field-of-view 40º 45º 15º 0º 15º 30º 230 230 230 30º 230 230 200 40º 45º 55º 150 55º 160 120 FL4000 IR3 - Competitor A IR3 - Competitor B 15 100 50 comparison of the FL4000 vs. competitive technologies is presented in Figure 3 above for the high sensitivity setting. The FL4000 provides a longer range of flame detection (230 feet) while maintaining a wide field of view. Table 1 shows the FL4000 s field of view at various 15 120 160 Figure 3: FL4000 vs. FOV of Competitors Products. distances. The FL4000 offers the largest angular coverage at the longest detection distance amongst flame detectors within the marketplace. Detection Distance * 230 ft 120 ft 50 ft Max. FOV 60º 90º 100º Table 1: Field of View vs. Detection Distances The advanced MSIR/NNT sensing system is highly immune to false alarms caused by lightning, arc-welding, hot objects, and other sources of radiation. In addition, the MSIR/NNT flame detector can see through dense smoke created by fires such as those from diesel, rubber, and plastics. The FL4000 is a highly discriminating multi-spectral IR flame detector, which makes use of infrared detectors covering different IR spectrum wavelengths and characteristics. With its highly reliable NNT flame discrimination algorithm, it classifies the output signals from the detector as either flame or non-flame. This combination of MSIR sensor package with NNT provides a flame detection system that is highly immune to false alarms. The MSIR / NNT-based FL4000 has a flame detection range of 230 ft. yet provides far superior false alarm immunity, for example, to arc welding, see Table 2. Technology Distance FL4000 (MSIR/NNT) IR 3 (Competitor A) IR 3 (Competitor B) Detection Range * 230 ft 210 ft 200 ft Table 2: Arc Welding Immunity Comparison Immunity Distance > 10 ft > 40 ft > 40 ft *Measured with a standard n-heptane fire in a 1 sq. ft pan at high sensitivity. www.generalmonitors.com

For applications that do not require long range flame detection, the FL4000 can be used with medium or low sensitivity settings. Reducing sensitivity may also prevent the flame detector from responding to controlled flame sources outside the area that is being monitored. Figure 4 shows the detection coverage of the FL4000 as a function of sensitivity setting. Note that the field of view is not compromised by choice of sensitivity. Additionally, the application of NNT enables the FL4000 to detect large flames or close-by flames that fill the entire field of view of the detector. 15º 0º 15º 230 30º 30º 35º 35º 45º 45º 50º 50º High Medium Low 120 60 Figure 4: FL4000 detection coverage for three sensitivities MSIR/NNT optical flame detection also allows the user to customize the detector to ignore difficult-to-recognize facility-specific false alarm sources. Often the unique design of a company s proprietary process or assembly line creates flame false alarm sources. In such situations the characteristics can be programmed into the detector as known nuisance sources (utilizing the MSIR/NNT algorithms) to be ignored by the flame detector. Large companies with multiple facilities relying on standardized plant designs can then replicate the lessons learned at a single facility to all their installations. This adaptive learning capability further enhances the false alarm discrimination and widens the applications for the MSIR/NNT. Built-in COPM (Continuous Optical Path Monitoring) self-diagnostic circuitry in the FL4000 checks both the optical path integrity (window cleanliness) and the detector s electronic circuitry once every two minutes. Serial communication ports designed into the instrument allow 128 units (247 units using repeaters) to be linked up to a host computer using the MODBUS RTU protocol. The communication registers provide alarm status, fault and other information for operation, trouble-shooting or programming the unit. The electronics are integral within an explosion-proof stainless steel housing, allowing detector information to be processed at the point of detection. Conclusion Neural network technology is a proven solution across a wide range of industries. When NNT is combined with a multi-spectral optical IR sensor package, the resulting MSIR/NNT technology becomes a powerful next generation solution for flame detection with distinct advantages over the various UV, IR, UV/IR, dual and triple IR flame detection devices on the market today. MSIR/NNT flame detectors, with their custom programming capabilities, also represent a highly productive and cost-effective solution to persistent nuisance alarm sources. They can be programmed to recognize and ignore the footprints of such false alarm sources. This knowledge can be easily replicated in flame detection systems supporting large plant or standardized multi-plant operations. The Model FL4000 Flame Detector extends the performance parameters of existing optical flame detectors in terms of distance, field of view, accuracy and false alarm immunity. These advantages, in many applications, will reduce the number of detectors necessary for optimum coverage, thus cutting total installation cost while still providing superior performance and protection from false alarms. 8

Ardem Antabian is the Product Manager, Flame and Gas Detectors, at General Monitors where he has global responsibility for business and product development. He can be reached at ardema@generalmonitors.com. Shankar Baliga, Ph.D. is Group Manager, Sensors at General Monitors where he is responsible for the development of new optical and chemical technologies for gas and flame detection. He can be reached at shankarb@generalmonitors.com. Javid Huseynov is a Senior Software Engineer at General Monitors specializing in neural networks, signal processing and algorithm design. He is currently a Ph.D. candidate at the School of Information and Computer Science, University of California Irvine. He can be reached at javidh@generalmonitors.com. For additional information: Phone: 949-581-4464 Email: info@generalmonitors.com

26776 Simpatica Circle Lake Forest, California USA 92630 Phone: +1-949-581-4464 or +1-866-686-0741 Fax: +1-949- 581-1151 Email: info@generalmonitors.com 9776 Whithorn Drive Houston, Texas USA 77095 Phone: +1-281-855-6000 Fax: +1-281-855-3290 Email: gmhou@generalmonitors.com Ballybrit Business Park Galway, Republic of Ireland Phone: +353-91-751175 Fax: +353-91-751317 Email: info@gmil.ie P.O. Box 61209 Jebel Ali, Dubai United Arab Emirates Phone: +971-4-8815751 Fax: +971-4-8817927 Email: gmme@emirates.net.ae No. 2 Kallang Pudding Rd. #09-16 Mactech Building Singapore 349307 Phone: +65-6-748-3488 Fax: +65-6-748-3488 Email: genmon@gmpacifica.com.sg Heather Close Lyme Green Business Park Macclesfield, Cheshire United Kingdom, SK11 0LR Phone: +44-1625-619-583 Fax: +44-1625-619-098 Email: info@generalmonitors.co.uk www.generalmonitors.com 2005 General Monitors. All rights reserved. WP-FL4000-A1105