Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Similar documents
UV - flame detector dual fuel burners for intermittent burner operations

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMPACT FLAME CONTROLLER CFC 100

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Technical Description Relay Module Flame Detector

Chemical Processes in the Combustion

UV Flame Supervision System

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Infrared Flame Detectors

DATASHEET. Burner control unit FDA 601x

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Gas Turbine Flame Monitoring

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

Infrared Flame Detectors

Flame Monitors BROCHURE

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

QRA10... QRA53... QRA55...

Flame Safeguards LFE10. Building Technologies HVAC Products

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Products Catalog. Flame Monitoring & Evaluation Systems

RAR... Photocell Detectors. Building Technologies Division

QRA10... QRA53... QRA55...

Burner control unit BCU 370

FLAME AMPLIFIER MODULE 3001

Fireye FLAME SCANNERS

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

MBCE-110/230UV Flame Sensor Module

FIREYE C9707A ALL FUEL SCANNER

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

QRA10... QRA53... QRA55...

Design Manual Installation Operation Maintenance

Burner control unit BCU 370

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

FIRERAY 5000 range USER GUIDE

Flame Simulator User Manual. Publication Rev. A

Flame detector. The QRA4.U is for use with the following types of burner control:

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

Flame detector FD 2011 / FD 2012

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

LFL Series Burner Flame Safeguard Control

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Operating Manual MS220KA and MSR220KA

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

QRA10... QRA53... QRA55...

Testing Emission Source ITES Operating Manual OM

Operations Manual. Motion Detector Module Model ZS10

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Mercury Vapor Monitor VM-3000

NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

55 years of know how on flame monitoring systems from Leipzig

Dated 15-Dec-2000; J. Schilz, subject to change

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

FLAME AMPLIFIER MODULE 3001D

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

IFD-E Flame Detector User Manual

C Note! LGI16... Burner Controls. Building Technologies

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Products Catalog. Flame Monitoring & Evaluation Systems

ALPHA+ Light Exposure and Weathering Testing Instrument. Xenotest Alpha+ Features. Xenotest Alpha+ Specifications. Sample Capacity

Model 3300 Technical Support and Installation Manual

Flame detector. The QRA4.U is for use with the following types of burner control:

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

LAE10 LFE10. Use. Series 02

Product Overview Combustion Technology

FLV 40 UV Flame Detector

WASTEWATER Online UV%Transmission Analyzer

LOW NOx MODULATING GAS BURNERS

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Danfoss gas detection units

IFD-E Flame Detector User Manual

Blue-flame Detectors

Panel Mounted Fault Annunciator Series

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

PRODUCT CONFORMITY CERTIFICATE

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Acessories BROCHURE JUNHO 2013

Advantages / Characteristics

INDUSTRIAL FLAME SCANNERS

Flame detector. Building Technologies Division Infrastructure & Cities Sector

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

VM-3000 Mercury Vapor Monitor

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

SPACEMOTION SERIES SMM 01

Table of Contents. 1. Mounting Tips... 2

Operating Manual MS220DA

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

Transcription:

KLC 20 0 (formerly known as KLC 2002) CE0085BP0001 Technical Information Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations Short Description The wide band flame detector KLC 20 is a compact flame detector, whichh is special designed for blue burning combustion systems. The patented evaluation of the flame signal is based on the flicker frequencies of the flame. A RISC-Processor enables the evaluation and conversion of the flame signal into digital information to provide an output signal for burner control boxes. All flames will be detected by an automatic sensitivity control. Adjustments during commissioning and maintenance are not necessary! Due to international standards the flame detector KLC 20 will only detect signals caused by the flicker of the flame and no signal from continuous radiation and all kinds of constant frequency. These fare signals caused by disturbing light sources, e.g. fluorescent tubes or background radiation from hot refractories will be cut off, so that unwanted influences are not possible. The flame detector is equipped with an optical interface to get online information about monitoring of flame signal and serial number.

Safety Instruction The KLC 20 is a safety component, so it is absolutely forbidden to open, to manipulate or to misuse this flame detector! Replace the flame detector in case of any damage, fall, shock, moisture, wetness or influences, which can destroy the flame detector, even though it is not recognizable! Repair works are strictly prohibited! Before working at the flame detector switch off the power supply. Before first commissioning or replacement of the device check the wiring! Technical Data Input: AC 230/240 V (-15/+10%) AC 115 V (optional) Frequency 50 60 Hz DC 24 V (optional) Consumption typical 3 4 ma Output: Switch-On Delay after energizing from safety relevant self check to final operating condition typical 2 sec. Switch-On delay after Flame On typical 0.5 sec. Switch-Off time after Flame Off <0.5 sec. max. switching current 15 ma, max. switching power 0,3 W max. switching voltage 280V AC / 400V DC Optical Features: Spectral range 380 1150 nm, Peak wavelength 920 nm Flicker frequencies 15 400 Hz Switch on frequency: Switch off frequency: 52 Hz dominant flicker frequency 15 Hz dominant flicker frequency Acceptable loss of flame signal ca. 280 ms Disturbing > 35Hz (optionally) Operating Temperature: -20 to +60 C Humidity: max. 95%, no condensation permitted Optional for higher temperatures Operating position: any position Kind of protection: IP 41 Protection Class: II Protection against electric shock: DIN EN 60730-2-5 (mounted) weight: 0.029 kg max. length of connection cable: 1 m (optional for longer cables) Certification: CE0085BP0001 * * only versions with the function " Disturbing " - 2 -

Block diagram Mounting instructions The KLC 20 should be mounted close to the flame with straight alignment. The compact flame detector should be mounted with the mounting flange KLC or another suitable holder with Ø14 mm opening. The radial adjustment to the flame is realised with the viewing angle adapter KLC and replaces the mounting flange KLC. Fix the detector with the holder. The best flame signal will be achieved from strong flickering parts of the flame radiation. The angle of view, especially with sight tubes, must be of appropriate dimensions to avoid any reduction of flame radiation. Protect the sensor against other light sources. To avoid any disturbance, do not align the detector direct to the ignition spark. Breakdowns during preventilation procedure may occur. The maximum length of the connection must be in accordance with the technical data. Install the detector connection cable with most possible distance to the ignition cable. Attention: For safety reasons and technical regulations a controlled burner shut down of at least once per 24 hours must be guaranteed. - 3 -

Mounting flange KLC The mounting flange KLC serves for to the admission, attachment and adjustment of the flame detector. Two overall heights with 7 and 13mm are available. By means of an O-ring the mounting flange KLC can be simply sealed to the burner housing. Viewing Angel Adapter KLC for radial adjustment With the optionally available viewing angle adapter by means of an optimally formed out reflector surface the radial adjustment of the KLC is accomplished 20 to the flame axle. The angle adapter replaces the mounting flange KLC. Separate type of automatic flame guard is not necessary therefore. With maintenance work the reflector surface is to be controlled on possible contamination and if necessary it is to clean with a clean, soft and lint free cloth. Adapter ADP The adapter ADP makes it possible to mount the flame guard series KLC with axial adjustment directly to the combustion chamber. The integrated quartz glass is used as pressure barrier and prevents the withdraw of heat gases from the burner. In case of higher temperature at the surface we offer a heat insulating ADP. - 4 -

Dimensions 13,5 30 115 22 Viewing Angel Adapter KLC: 50 55 7,5 19 4,5 26 35 69 7 48 all dimensions in mm Connector Diagram KLC 20 Control boxes Dungs / Satronic Type of control box MPA 22 TF 8.. DKO 9.. DKW 9.. DMO 9.. TMO 720-4 Blue terminal no.: 12 5 N 2 2 2 Black terminal no.: 12 3 Ion 1 1 1 LED Brown terminal no.: 6 17 L1 9 9 9 Ask for connector details of other burner control boxes. - 5 -

Operating Indicator LED Via the built-in LED the flame detector KLC 20 is indicating the following operating conditions: LED is OFF: LED is blinking: LED is ON: KLC is not active KLC is active, safety test finished, no flame detected KLC is active, safety test finished, flame detected Function Disturbing The KLC 20 is optionally available with the function disturbing. With this option the KLC 20 detects only real flames, which are characterized by unsteady changing flicker frequencies. Constant light and every constant frequency e.g. from fluorescent tube or other electrical lamp, are cut off and won t lead to a permanent flame detection. In this case the KLC 20 will switch the output a first but after a period of about 9 seconds the KLC 20 will switch the output off again. During revision it has to be kept in mind that this property is intended and no malfunction. Commissioning and Maintenance The installation and commissioning has to be done by qualified personnel only. Before energizing check the cabling and wiring in accordance to the diagram. To maintain the detector just keep the sight glass clean by using a dry cloth. Do not use any kind of cleaning sprays or liquids. Use only the ribbed area to pull out or plug in the flame detector to the mounting flange. A simple test of the switch on and off function is to use a normal AC light source. The standard version will switch the flame relay and the red LED shines permanently. With the optional version disturbing cut off function the relay will be interrupted after about 9 seconds and the red LED blinks. The detector KLC 20 is a self-checking device, further tests are not necessary at any time. Important note: By the safety function of the disturbing, a flame simulation is not possible by means of a simple art source of light. If a flame simulation, e.g. during the final inspection of the burner without a real flame, is needed, a source of light with a modulating frequency between 60 and 150 cycles per second or the flame simulation device TG10 is to be used. Diagnostic with KLC com With the data interface KLC com, consisting of optical adapter with cable, interface (USB) and software, the following information can be read from the KLC 20: - Impulses - Serial Number - Version / Edition - present flicker frequency For connection place the optical adapter to the opening at the LED. Via the connection cable and the interface the a.m. information will be transferred to a Laptop or PC by using the special software. Further information is available in the manual KLC com. - 6 -

Overview of articles Article Version Part-No. Flame detector KLC 20/230 611120110105 Flame detector KLC 20/230 and optical 611120112105 IR Filter Flame detector KLC 20/230 Axial, without disturbing * 611120210105 Flame detector KLC 20/120 611220110105 Flame detector KLC 20/120 Axial, without disturbing 611220210105 Flame detector KLC 20/24 611320110105 Flame detector KLC 20/24 and optical 611320112105 IR Filter Flame detector KLC 20/24 Axial, without disturbing 611320210105 Mounting flange KLC overall height 7 mm 665001010000 Mounting flange KLC overall height 13 mm 665002010000 Viewing angle adapter KLC ADP 11 - UV ADP 21 - UV Accessories for radial mounting applications Adapter for direct mounting applications Adapter for direct mounting applications, heat insulating 615001020000 575010512210 575010512230 Connecting cable KLC length 300mm 661030040100 Connecting cable KLC length 350mm 661035040100 Connecting cable KLC length 600mm 661060040100 Connecting cable KLC length 1000mm 661100040100 Connecting cable KLC length 2000mm 661200040100 Connecting cable KLC Data interface KLC-Com, USB On request optical adapter, USBinterface, Software 731000080980 Flame simulation device TG 10 730061010900 * Versions without disturbing are not permissible for gas applications Disposal information The flame detector is equipped with electrical and electronic components and must be disposed separate from household waste. Follow the local and actual regulations for waste disposal. - 7 -

UK Authorised Distributor: HeatSol Technology Limited 9,Buckholt Business Centre Buckholt Drive Warndon Worcester WR4 9ND Telephone: 01905 457557 Fax: 01905 759515 Email for sales: sales@heatsol.co.uk Email for technical advice: info@heatsol.co.uk BST Solutions GmbH Eggerscheidter Straße 57 D - 40883 Ratingen Telefon: +49 (02102) 1005959 Telefax: +49 (02102) 1005979 Email: info@bst-solutions.de http://www.bst-solutions.de DIN EN ISO 9001:2000 Zertifikat: 09 100 5438 BST Solutions 2015 technical modification reserved Revision 1-8 -