PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

Similar documents
PT Radiant Heater Range

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

CP+ Gas & Oil Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

Powrmatic PZN / PZN X Hot Water Heater

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

HEM Heat Exchange Modules

NVxEA External Gas Unit Heater

VPC Gas Cabinet Heater Range

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Powrmatic Control Systems Industrial & Commercial Heating Systems

Powrmatic PQ Electric Quartz Infrared Heaters - A Range

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

Destratification Fans Industrial & Commercial Heating Systems

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

NVx Suspended Gas Unit Heater

AMBIRAD.... Vision Radiant Tube Heating Systems...

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

Installation Instructions

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

PQ-A Electric Quartz Infrared Heaters

BENSON LINEAR RADIANT TUBE

Flue & Flue Kits for NVx, VPC & NVS

CECx Destratification Fan

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR REZNOR VISION VS RANGE OF RADIANT TUBE HEATERS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

Dovre 250 Cast Iron Gas Stove

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Sirius FS. Working towards a cleaner future

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options

Herringbone Linked Flue System

Assessment Schedule - TS.6

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

RHC GAS FIRED HEATING COILS

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

HHG610SS 60cm 4 burner gas hob. HHG710SS 70cm 5 burner gas hob

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

This manual must be kept with the appliance

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

RHC & RHCE gas fired heating coils

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

INSTALLATION AND OPERATING MANUAL. Vision VS Radiant

BENSON.... Variante3 Fired Unit Heaters...

G34M Bulletin #69/ August 2003

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

VORTEX BLUE OIL RANGE

ferroli Boiler Replacement Maxima 35C- Modena HE

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS SALAMANDER

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

MHG201 Gas Hob Manual for Installation, Use and Maintenance

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Copper-Fin GAS-FIRED WATER HEATERS

BENSON VARIANTE 2 RANGE

PREEVA air handling unit

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK

Gas-fired unit heaters for indoor installation

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Transcription:

PT Radiant Heater Range Controlling your working environment heating ventilation integrity 1

PTUL and PTSL Radiant Tube Heaters PTUL / PTSL Radiant Tube Heaters Part L 2010 Compliant - High Efficiency Versions also available Six input ratings: 15kW to 47kW available in Linear and U models Herringbone link flue systems available with all U and Linear models Heat treated Aluminised Calorised emitter tube surface - for flake free and cleaner working environment. Natural Gas and Propane Aluminium reflectors - the tested and proven superior material - designed to maximise downward radiant heating effect Lightweight construction - 4 tubes supplied in 3m sections - easy to assemble and fit CE Approved Efficient and cost saving heating method Manufactured in the UK to ISO9001:2008 quality assured system All units test fired before despatch 2

PT Series Part L 2010 Compliant & High Efficiency Ranges Duties Model ptul & ptuh *15 25 30 35 40 45 Heat Input, Hs (Std) kw 15.0 23.0 29.2 34.5 42.2 47.0 Length - A mm 3100 5385 5510 6970 Width - B mm 460 715 Height - C mm 175 210 Weight Kg kg 31 47 66 81 Gas Connection R - 1/2 Supply Pressure mbar Natural Gas - 20 Propane - 37 Flue Diameter mm 127 Air Inlet Connection mm 101.6 Model ptsl & ptsh *15 25 30 35 40 45 Heat Input, Hs (Std) kw 15.0 23.0 29.2 34.05 42.2 47.0 Length - A mm 5495 10065 9955 13000 Width - B mm 460 340 Height - C mm 175 180 Weight kg 27 46 62 79 Gas Connection R - 1/2 Supply Pressure mbar Natural Gas - 20 Propane - 37 Flue Diameter mm 125 Air Inlet Connection mm 101.6 Model ptdsl only 15 25 30 35 40 45 Heat Input, Hs (Std) kw 30.0 46.0 58.4 69.0 84.4 94.0 Length - A mm 10934 20078 19858 25948 Width - B mm 340 Height - C mm 392 Weight kg 60 92 124 158 Gas Connection R - 1/2 Supply Pressure mbar Natural Gas - 20 Propane - 37 Flue Diameter mm 150 (Note 125 allowable) Air Inlet Connection mm 101.6 Dia Recommended Mounting Height (General guidance only) Model PTU/PTS 15 PTU/PTS 25 PTU/PTS 30 PTU/PTS 35 PTU/PTS 40 PTU/PTS 45 Horizontal m 2.4-6.0 3.0-8.0 3.8-10.0 4.0-12.5 4.8-13.5 5.6-15.0 Angled > 30 m 2.1-4.5 2.7-5.0 3.3-7.0 3.7-8.0 4.0-9.0 4.8-11.0 Minimum Clearances to Combustible Material - mm Model Side Above Below End Front Rear PTU / PTS 15 450 450 1220 450 575 305 PTU/PTS 25 510 450 1220 510 610 305 PTU/PTS 30-45 760 610 2285 610 760 380 * Notes: High efficiency units are only available from size 25 upwards. Double Linear tubes are not yet available in the High Efficiency range. 3

Drawings PTUL & PTUH A C B PTSL & PTSH A C B PTDSL A C B 4

Optimum floor coverage dimensions (in metres) at given heights - horizontal mounting PTSL/H 15 PTSL/H 25 PTSL/H 30 PTSL/H 35 PTSL/H 40 PTSL/H 45 Height (m) X Y X Y X Y X Y X Y X Y 4m 12 8 16 8 16 8 16 8 5m 13 9 17 9 17 9 17 9 20 9 6m 14 10 18 10 18 10 18 10 21 10 21 12 7m 19 11 19 11 19 11 22 11 22 14 8m 20 12 20 12 20 12 23 12 23 15 9m 20.5 13 20.5 13 23.5 13 23.5 16 10m 21 14 21 14 24 14 24 14 11m 21.5 15 24.5 14 24.5 15 12m 22 16 25 14 25 16 13m 25 14 25 16 14m 26 16 15m 26.5 16 PTUL 15 PTUL/H 25 PTUL/H 30 PTUL/H 35 PTUL/H 40 PTUL/H 45 Height (m) X Y X Y X Y X Y X Y X Y 4m 11 8 13 8 13 8 5m 12 9 15 10 15 10 15 10 16 10 6m 14 10 16 12 16 12 16 12 18 12 18 12 7m 17 13 17 13 17 13 20 14 20 14 8m 18 14 18 14 18 14 21 15 21 15 9m 18.5 15 18.5 15 22 16 22 16 10m 19 16 19 16 22.5 16.5 22.5 16.5 11m 19.5 17 23 17 23 17 12m 20 18 23.5 17.5 23.5 17.5 13m 24 18 24 18 14m 24.5 18.5 15m 25 19 PRP Radiant Plaque Heaters Model PRP 08 PRP 15 PRP 22 PRP 30 Input Rating - natural gas kw 7.60 15.20 21.00 30.40 Input Rating - lpg kw n/a 15.00 n/a 30.00 Length mm 615 895 1175 1425 Width mm 428 435 435 435 Height mm 325 385 385 385 Weight kg 6.0 11.0 14.0 24.0 Electrics V/ph/hz 230/1/50-25w 0.11A, fused externally 3A Gas Connection Rc 1/2 Supply Pressure mbar NG - min 17, max 25 lpg - min 25, max 45 5

installer guide General the following note are provided as a help, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. For copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Standards all Powrmatic Pt, PtS and PtDS radiant tube heaters are specifically designed for environmental space heating applications only and must be installed, commissioned and operated with due regard to appropriate regulations including but not limited to the gas Safety (installations and Use) regulations 1998 for gas fired products, the health and Safety at Works act 1974, relevant Codes of Practice, BS13410:2001 and other relevant standards, the possible requirements of local authorities, Fire officers and insurers as well as Powrmatic s installation manual. Position,Location & Assembly Powrmatic Pt, PtS and PtDS radiant heaters are designed for internal location only. effective heating is dependent upon mounting height as well as location within the building or heated zone. Minimum as well as maximum mounting heights must be observed. Please refer to page 5 for further information. Suspension materials must be non-combustible and of sufficient strength and integrity to support the weight loading. heaters must be supported from permanent structures and on no account from gas lines or other pipework. heaters should be supported along the entire length using the appropriate mounting points provided. linear heaters should have a 0.25o slope upwards towards the burner. Consideration should also be given to flue routes and points of exit, gas, electrical and control connections, the radiant heating characteristics of the heater, issues of public access and the siting of environmental control stations and/or remote temperature sensors where the position needs to be representative of the zone temperature to which they refer. heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn into the combustion air circuit. effective and safe operation heaters is entirely dependent upon correct on-site assembly of the constituent parts. the assembly instructions provided must be strictly followed. in all cases installers must refer to the installation, operation and Maintenance manual prior to commencing works. Combustion Air, General Ventilation & Fluing Within the United Kingdom mandatory regulations apply concerning the provision of combustion air and general heater ventilation. Powrmatic radiant tube heaters types Pt, PtS and PtDS may be installed in either vented (flued) or unvented (unflued) mode. Specific regulations and requirements apply for the safe evacuation of flue gases. installers must refer to the installation, operation and Maintenance manual prior to commencing works. Installation Clearances Particular clearances are necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. Pipework Care should be taken when sizing gas pipework to ensure that minimum gas inlet pressures are not compromised under dynamic load conditions. isolating valves and service unions should be provided for each heater and pipework installed with due regard for relevant standards and Codes of Practice. the final connection to the heater must include a suitable flexible gas pipe so that the fixed element of gas pipework cannot be influenced or effected by expansion and movement of tube heater. Guarantee Powrmatic Pt, PtS and PtDS radiant tube heaters are provided with a comprehensive guarantee. For United Kingdom sales the heater has the benefit of a two year parts and one year abour guarantee. all guarantees are subject to terms and conditions. Powrmatic Ltd Hort Bridge Ilminster Somerset TA19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk Powrmatic Ireland 45 Broomhill Close Tallaght Dublin 24 tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. issue 2.1 - January 2012