Manual Wöhler Rotary Viper Vent M 10

Similar documents
SIMPLE. QUICK. CLEAN.

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

BlueHeat AirTop 2000 Heater

Mechanical seals external, single or double, to DIN EN 12756

LIFA AIR Air duct cleaning. Machines for air ducts and industrial process pipeline cleaning

Mechanical Seal RG-4 stationary, double, liquid sealed

Wöhler DM Operating Manual Digital Manometer

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Compressed-air grinder. AirMAX 230F. Instruction manual

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Power-Spin. Drain Cleaner Operator s Manual

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

FSW300 Series Flow Switch

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Visit us at

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

ENERVEX RSV CHIMNEY FAN

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

Installation manual for room air conditioner

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

INSTANT HOT WATER DISPENSER

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

SS-969 SMD Rework Station

CENTAFLEX Series A Assembly and operating instructions CF-AR M EN Rev. 2

AXPR Wall Mounted Axial Panel Fans

C0-210 Carbon Monoxide Probe

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

USER MANUAL UN-200V / UN-200VH

56" Instruction Manual REMOTE CONTROL CEILING FAN WITH LIGHT RCF-LE800-5BL SAFETY GUIDELINES AND INSTALLATION PROCEDURES

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

OPERATOR S MANUAL STANDARD BALL BEARING CHESTS & ROLLER CABINETS

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Removal. CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner.

ENERVEX GSV GREASE FAN

OPERATION MANUAL U L US LISTED CM12 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

Chapter 3 Cooling, heating and ventilation systems

USER S MANUAL. VKP Series INLINE FAN

an ISO 9001:2015 Registered Company

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

Avensys Avensys FIN EST SLO RUS UAE

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

VENTILATION FAN WITH LIGHT AND HEATER

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Models , Equinox, and Sirens Clutch Replacement Service Manual

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL

Mounting and Operating Instructions EB 2231 EN

GSV 9-16 Grease Fan for Solid Fuel Applications. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

150MM ELECTRIC EARTH BORER

BMW E36 Thermostat Removal And Coolant Flush

ELECTRIC DRILL INSTRUCTIONS. Item #21285

! WARNING. Before using product, read and understand instructions.

Rotary Gutter Cleaning System. Operator s Manual

Avensys Avensys FIN EST SLO RUS UAE

Installation Guide COMBI. Before installing read this guide first

READ AND SAVE THESE INSTRUCTIONS

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

GB162 Concentric Horizontal Vent Kit

Installation instructions

ENERVEX IPVB INLINE POWER VENTER

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

Purge Ventilation Unit. Product Manual. ventilation systems TP625

ComPact Air Drive II USER S MANUAL

Porter & Charles OPERATION MANUAL. Gas Cooktop CG60S, CG76S, CG90S, CG60W, CG90W

EHA Hoffmann International GmbH

HEATING AND AIR CONDITIONING

Instruction manual for downdraft hood

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Dosing system. Commissioning and maintenance manual eco-pen300

Desoldering Tool. Instruction Manual

Installation Instructions. Mira LED Light System

20 High velocity Air

Ice Pro DB650, EDB650 Automatic Ice Bagging and Dispensing System

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

Transcription:

Manual Wöhler Rotary Viper Vent M 10 Best.-Nr. 21884 20 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

Contents Contents 1 General Information... 12 1.1 Operation Manual Information... 12 1.2 Notes... 12 1.3 Intended Use... 12 1.4 Scope of supply... 13 1.5 Transport and storage... 13 1.6 Manufacturer... 13 2 Specifications... 14 3 Overview... 15 4 Preparing for use... 15 4.1 Fitting the cleaning attachment... 15 4.2 Connecting the power drill... 16 5 Using the rotary viper... 17 7 Maintenance... 18 8 Warranty and Service... 19 8.1 Warranty... 19 8.2 Service... 19 9 Accessories... 19 11

General Information 1 General Information 1.1 Operation Manual Information This operation manual allows you to work safely with the Wöhler Viper Vent. Please keep this manual for your information. The Wöhler Viper Vent Set is to be used by professionally trained personnel exclusively for the purpose for which it was designed. Liability is void for any damages caused by not following this manual. 1.2 Notes WARNING! Not following this warning can cause injury or death. Not following this note can cause permanent damage to the device. NOTE! Useful information 1.3 Intended Use The Rotary Viper Vent is suitable for cleaning ventilation lines, regulated dwelling VAC systems, air ducts up to Ø 250 mm, exhaust gas lines from 80-150 mm, connecting flue pipes and flue outlet pipes of tiled stoves. A mains powered or rechargeable-battery powered drill is used to rotate the threaded cleaning attachments (brush heads and impact brushes). The scope of supply does not include a mains powered or rechargeablebattery powered drill.

General Information 1.4 Scope of supply Meter Basic equipment Wöhler Rotary Viper Ventilation M 10 Rotary Viper Vent Brush Head Perlon (Ø 18 cm) EN Depending on set configuration: Optional cleaning heads 1.5 Transport and storage The device may be damaged if improperly transported or stored! Observe the smallest bending radius of 12 cm when storing and transporting. Ensure the rotary viper is not exposed to direct sunlight over a very long period of time when being stored, as this can damage the protective sheath. 1.6 Manufacturer Wöhler Technik GmbH 13

Specifications 2 Specifications Rotary viper Length 1.5 m or 3 m or 5 m or 10 m or 15 m Max. torque Clockwise rotation: 3 Nm Anticlockwise rotation: 1.5 Nm Failure moment Clockwise rotation: 9 Nm Anticlockwise rotation: 4.5 Nm Max. speed Clockwise rotation: 1300 rpm Anticlockwise rotation: 650 rpm Smallest bending radius Coat 120 mm Material: PA 12 mm Ø Connection for cleaning attachments Operating temperature M10 thread 0 - +80 C 14

Overview 3 Overview 3 1 2 Fig. 3: Components of the Wöhler Rotary Viper Vent Legend 4 Rotary viper 4 Preparing for use 4.1 Fitting the cleaning attachment 5 Power drill connector 6 Cleaning attachment, here Perlon brush head Use only brush head or impact brush attachments made of Perlon. 15

Preparing for use 2 1 Screw the locknut (3) on to the cleaning attachment. Screw the cleaning attachment (brush head or impact brush) (1) into the coupling (2). Use a wrench to hold the locknut in position and tighten the cleaning attachment using a second wrench. 3 Fig. 4: Cleaning attachment (1) coupling with female thread M10 (2) and locknut (3) NOTE! It is particularly important to tighten the cleaning attachment using two wrenches, because this will ensure the cleaning attachment will not work loose in use. 4.2 Connecting the power drill WARNING! If the brush suddenly becomes blocked, there is a risk the power drill will be ripped violently out of your hands. Consequently, we recommend you use a power drill with a torque clutch. Insert the power drill connector of the rotary viper into the drill chuck. Observe the instructions in the operating manual belonging to the power drill and obey the safety instructions in particular. 16

Using the rotary viper 5 Using the rotary viper Before using, unroll the rotary viper fully. Power on the power drill to make the cleaning attachments rotate. The rotary viper must only rotate clockwise. If it rotates anticlockwise, there is a risk the attached brush will work loose. Clockwise direction of rotation: Max. 1 300 rpm with cleaning attachment Anticlockwise direction of rotation: Max. 650 rpm with brush head Friction will cause the temperature of the sheath to rise if the rotary viper is used for longer periods of time. Ensure the specified operating temperature of 80 C is not exceeded, otherwise the sheath of the rotary viper will be damaged. Do not tread on the rotary viper when it is in use. Do not allow it to strike against the floor. That could damage the sheath of the rotary viper and degrade its anti-friction properties. Avoid overloading: If the cleaning attachment can no longer rotate in a pipe, stop the rotary viper rotating and push it through the pipe to be cleaned without any rotation. Rotate the cleaning attachment of the rotary viper first when you are pulling it back. 17

Maintenance 7 Maintenance The Wöhler rotary viper requires very little maintenance. The bearings in the end pieces are self-lubricating. The core is sufficiently greased with high-quality graphite lubricant. After it has been in use for a long time it is possible that the grease in the core will need to be replenished. This will become noticeable by the protective PA sheath becoming unusually warm. It should be returned to the factory for the grease to be replenished. 18

Warranty and Service 8 Warranty and Service 8.1 Warranty Each Wöhler Rotary Viper Vent will be tested in all functions and will leave our factory only after extensive quality control testing. If used properly, the warranty period for the Wöhler Rotary Viper Vent will be twelve month from the date of sale. Not covered by the warranty are cleaning attachments (brush head made of Perlon or threaded brush), because they are consumables. This warranty does not cover the freight and packing costs when the device is sent to the factory for repair. Service by non authorized personnel or making modifications to the analyzer voids any warranty. 8.2 Service Wöhler has built our reputation on excellence in customer service. Therefore, of course, we are readily available to assist you after the warranty period ends. Send us the device and we will repair it and return it to you with our package service. Immediate help is provided by our technical staff over the telephone. 9 Accessories Brush Head, Perlon 12,5 cm Ø, M 10 Order no. 1458 Brush Head, Perlon 18 cm Ø, M 10 Order no. 1466 Brush Head, Perlon 25 cm Ø, M 10 Order no. 7102 Threaded Brush, Perlon, 30 cm Ø, M 10 Order no. 18730 Wöhler Soot Door Sealing Order no. 3380 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com