1 Operation - Maintenance PR, CTF Optional Items E ENG For precise metering, mixing, and dispensing of two-component materials. For professional use only. 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Working Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save all instructions. PR4 shown 1

2 Contents Safety Precautions...3 Feed Options General Information...4 Vacuum Ready Lid...5 Gravity Feed Tank...8 Vacuum Pumps...9 Electric Agitator...11 Pneumatic Drive Agitator...12 Drum Feed Kit...13 Accumulator...14 Slinger Plate...15 Vacuum Ready Lid with Shower Head...16 Follower Plate...17 Nitrogen...18 Desiccant Dryer...19 Heat...20 Twindispense...21 Hydracheck...22 Customer Signal...27 Grease Option...29 Interlock...30 Technical Data...31 Graco Standard Warranty...32 Graco Information

3 Safety Precautions This manual provides installation, operation, and maintenance instructions for Graco Ohio Inc. meter, mix, and dispense machines. Read this manual before you install and operate your machine. Use your machine only as directed. Safety Terms within our manuals Cautions are given where failure to observe the instruction could result in damage to the equipment, associated equipment, and/or process. Warnings are given where failure to observe the instruction could result in injury or death to people. Some examples follow. Caution Snuff-back can be monitored with DV MODE in AUTO, but must be adjusted with DV MODE in OPEN WARNING Make sure EMERGENCY STOP is locked in before manually aligning the ratio block to the ratio beam. Safety Labeling on our machinery All our machines carry the following safety labels wherever necessary: Danger Labels indicate an imminently hazardous situation, which, if not avoided, could result in death or serious injury. Warning Labels indicate potentially hazardous situations which, if not avoided, could result in death or serious injury. Caution Labels indicate an unsafe practice that may result in moderate or minor injury. Notice Labels state a company policy. Some examples are: DANGER DO NOT OPERATE THIS MACHINE WITH GUARD(S) DETACHED WARNING UNPLUG MACHINE BEFORE OPENING ENCLOSURE NOTICE OVERCURRENT PROTECTION PROVIDED AT MACHINE SUPPLY TERMINALS CAUTION WEAR EAR PROTECTION CAUTION WEAR EYE PROTECTION 3

4 Feed Options General Information A complete tank consists of a lid assembly, tank, and optional outlet ball valve assembly The outlet ball valve assembly is required for all vacuum applications, and is included with all vacuum lid assemblies Vacuum lid assemblies include agitation All vacuum tanks are certified to 25 torr, for lower vacuum level applications consult factory All vacuum tanks allow for an additional room of 7.5 liters for material expansion All assemblies listed as stainless steel fittings are 303/304 grade or better Pneumatic agitators can be used with any self-leveling materials Electric agitators are recommended for materials with a viscosity of less than 100,000 centipoise Tank assemblies include tank stand for 2 tanks 4

5 Vacuum Ready Lid Vacuum Transfer draws material into the tank through a hose connecting the tank fill port and the material source. Test all machine features and controls before loading material for the first time. 1. Secure the tank lid. Pump Feed Ball Valve Closed Illustration 2. Close the pump feed ball valves on the bottom of the tank. 3. Connect a supply line from the material source to the fill port ball valve. 4. Turn on the air agitator to the desired speed. Provide a slow steady agitation (if equipped). Atmospheric Ball Valve Closed Material Tank Fill Port Ball Valve Open Vacuum Pump Ball Valve Open Material Fill Position 5

6 5. Close the atmospheric ball valve, turn the material tank vacuum pump on and open the vacuum pump ball valve. Note: If equipped will nitrogen, a nitrogen gas supply line may connected to the atmospheric ball valve. 6. Open the material tank fill port ball valve seen in the Material fill position illustration. Material will vacuum load into the tank. 7. From the CONTROL panel, watch for the HIGH indicator for the corresponding material tank. If your machine is equipped with no high level sensor then do not fill the tank passed ½ to 2/3 of the tank capacity. Material Tank Fill Port Ball Valve Open 8. Close the material tank fill port ball valve when the tank is full. This is seen when the HIGH indicator are illuminated. 9. Allow material to vacuum and agitate until it is fully degassed. Then, close the vacuum pump ball valve. Turn off the vacuum pump. Atmospheric Bleed Ball Valve Open Vacuum Ball Valve Closed Atmospheric Position Illustration 10. Open the atmosphere bleed ball valve. 6

7 NOTE: Some machine may have nitrogen gas or pneumatic pressure supply lines connected to the atmosphere bleed ball valve; in this is the case, then, open the atmosphere bleed ball valve and apply 2 to 3 psi, do not exceed the maximum psi rating labeled on the tank. 11. Open the material feed ball valve. NOTE: Skip the next step if the pump and hose are already primed with material. 12. At initial material loading, or after pump maintenance, do the following: a. Open the material feed ball valve. Allow all air to vent from the pump. b. Close the material feed ball valve. c. Repeat degassing steps to rid the material of the air that vented from the pump. 13. Open all material feed ball valve. NOTE: Repeat the degassing procedure any time you add additional material to the tank or vent air into the tank. 7

8 Gravity Feed Tank A Gravity Feed Tank uses the force of gravity to draw material into the pump. Test all machine features and controls before loading material for the first time. Do not operate machine with material under vacuum. 1. Remove the lid from the material reservoir. 2. Slowly pour or ladle the material into the tank (down the side of the tank wall preferably) to entrap as little air as possible. 3. Allow sufficient time for any air to vent from the pump. 4. Replace and secure the material tank lid, making sure that the vent valves are in the opened position. 8

9 Vacuum Pumps Details: 6.9 CFM Vacuum Pump package with pump mounted on/off switch, inlet chemical trap, outlet oil mist filter, and 1 in. x 120 in. vacuum rated hose and fittings for one tank. The package is designed for vacuum degassing of material in a vacuum rated feed tank. The degassing process helps to assure that dispensed material meets the target properties required for the application. Component List: Oil sealed rotary vane single stage 6.9 CFM vacuum pump with 0.75 HP, VAC or VAC, depending on selection, single phase, 50/60 Hz drive motor, cordset, and pump mounted switch. Pump is rated to obtain a maximum vacuum level of 0.1. Inlet chemical trap with activated carbon filter, sight glass and 1.8 liter capacity prevents froth or spray generated by the degassing process from carrying over to the pump. Trapped liquid level is visible in the sight glass and the hand-tightened drain plug allows easy draining. Outlet mist filter captures oil mist to assure a clean operating environment and meet regulatory requirements. An odor element neutralizes the smell of oil mist and the translucent lower filter allows visual oil level monitoring. Vacuum rated 1 in. x 120 in. hose and fittings are for connection to a vacuum rated feed tank. Operation W hen the oil is degassed, the pump will based out at or near it's published ultimate vacuum. It is helpful to keep a simple log book as eventually the ultimate vacuum will begin to degrade. This is one indication that the oil should be changed. Also, visual inspection of the oil is necessary to ensure pump longevity. If the oil begins to go dark it must be changed. Our application group recommends an isolation valve at the pump inlet with an appropriate vacuum gauge. A summary of operation and technique to base-line the pump include the following. NOTE: See the following image. 1. Change pump oil (necessary to adequately baseline the vacuum pump). 2. Install inlet isolation valve and appropriate vacuum gauge. 3. Close pump inlet isolation valve. 4. Turn on vacuum pump with gas ballast valve full open. 5. Run pump for 1/2 hour to allow pump to warm up (having the gas ballast open allows the pump to heat up faster). 6. Record base vacuum with gas ballast on (baseline with gas ballast open). 7. Close gas ballast valve and record base vacuum (baseline with gas ballast closed). 8. Open gas ballast valve to full on position. 9. Open inlet isolation valve at pump. 9

10 10. Execute process. 11. Once process is complete close inlet isolation valve at pump. 12. Run pump for at least 1/2 hour with gas ballast valve open to full. 13. Check and record pressure after 1/2 hour. Pump should baseline to pressure recorded with gas ballast open. Run longer if needed. 14. Close gas ballast valve. 15. Check and record pressure which should baseline to pressure recorded. 16. Turn off vacuum pump. Inspect oil and record color. Use the attached color chart and guidelines in attached document. 10

11 Electric Agitator Specifications The electric agitator assembly has a 0.5 HP AC electric motor, 30:1 gear reducer, and a shaft/blade assembly. A three position selector switch allows low speed (29 rpm), high speed (58 rpm) or OFF. For materials with a maximum viscosity of 100,000 centipoise and maximum material temperature of 275 F. General Info The Agitator Speed Controller enables/disables the electric agitator and also increases/decreases the tank agitator speed. OFF: The tank agitator is disabled and the material in the tank is not agitated. LOW: The tank agitator is enabled and the material in the tank is agitated at the minimum speed. HIGH: The tank agitator is enabled and the material in the tank is agitated at the maximum speed. 11

12 Pneumatic Drive Agitator The pneumatic drive agitator assembly has a 0.9 HP pneumatic motor, a 27:1 gear reducer, and a shaft/blade assembly. The pneumatic agitator includes a needle valve to adjust rotational speed from 10 to 160 rpm (water thin media). The pneumatic agitator is for materials with a maximum viscosity of 100,000 centipoise and maximum material temperature of 275 F (135 C). 12

13 Drum Feed Kit A drum to drum to pump feed kit consists of hoses, hose clamps, and fittings used to deliver material from the drum to the pump. Test all machine features and controls before loading material for the first time. 1. Close both ball valves on top of the drum. Disassembling the top drum feed piping assembly is done by grasping the brass-colored rings on the cam levers and pulling them away from the piping assembly. 2. With the new material drum in an upright position, remove the 2 NPT cap from the drum and replace it with the threaded end of the large male section (from the old drum). Close the ball valve. 3. Remove the 3/4 NPT cap from the drum and install the provided vent tube. 4. Connect the air dryer to the vent assembly (if required). 5. Close all ball valves. 6. Reconnect the top drum feed piping sections, between the pump inlet and the drum, by inserting the male section into the female section and squeezing the cam levers down snug against the piping.. 7. Install drum on rack. Open the ball valves on the drum material feed line, and the pump material feed line. Open the ball valves common to the vent. 8. Allow minutes for all air to vent from the pump and to the drum. CAUTION: The vent tube must be higher than the material level in a full drum. WARNING: Do not connect any pressure device to the vent tube assembly. 13

14 Accumulator An accumulator feed system is used with high viscosity materials to drive the material into the pump. The 4 in. diameter feed system is equipped with high and low level switches to activate a remote material transfer pump for automatic refill. The transfer pump is stopped when the high level switch indicates the accumulator is full. NOTE: Transfer pump not included. 14

15 Slinger Plate The slinger plate is a flat metal disc secured to the agitator shaft. It is used to spread low viscosity materials via centrifugal force, increasing the material surface area for rapid vacuum degassing. Slinger Plate 15

16 Vacuum Ready Lid with Shower Head This lid is complete with vacuum fittings, vacuum gauge, and shut-off ball valve with shower head. The material handing system for the day tank fills from the bulk feed (supplied by customer) using a vacuum pump (supplied by the customer). The vacuum ready lid is used with high viscosity material that will be pulled thru the shower head creating an umbrella-like stream into the day tank. This process increases the surfaces area of the material. The process is not desirable for low viscosity materials. Shower Head 16

17 Follower Plate The follower plate is a 9 in. diameter polyethylene plate with a handle. The plate rests on top of the material and moves down the tank as material is used, forcing the material into the middle of the tank and preventing cavitation. Follower Plate 17

18 Nitrogen The nitrogen option consists of a nitrogen harness with gauges and regulator. The gauges and regulator need to be connected to a nitrogen bottle. The hose quick disconnect fittings are connect to the mating quick disconnect fittings, on the tank lids. One of the gauges shows the nitrogen pressure from the nitrogen bottle. The other gauge shows the nitrogen pressure being fed to the material tanks through the regulator on the nitrogen harness. A typical blanket pressure should be 1-3 psi. The tank lid has a 5 psi pressure relief valve. This system can also be used for pressure feed systems. WARNING: If used for pressure feed systems, do not exceed the maximum pressure rating of the material feed tank. The nitrogen is used to pressurize the material tanks. This pressurization will place a dry nitrogen blanket on the surfaces of the materials in the tanks. NOTE: Nitrogen bottle not included. 18

19 Desiccant Dryer The disposable desiccant dryer provides dry make-up air and helps prevent moisture contamination. Operation at Installation a. Remove each of the plastic red caps on the filter elements canister that are in place for each of the A and B side material collection devices. b. Fill in the Installation Date sticker on the filter elements canister for each of the A and B side material devices. c. Replace device when the filter elements in the canister turn purple (see sticker). The filter elements in the canister are blue when new (see sticker). Desiccant Dryer 19

20 Heat Heat Controller Options There are four heat controller options. Each heat controller option provides one heat zone for each heated item in the system. If the system only has heated hoses, then the heat controller option is 2-Zone Low Wattage Heat. If the system has two items to heat and at least one is not a heated hose, the heat controller option is two Standard Heat Control Zones. If the system has four or six items to heat, the heat controller option is four or six Standard Heat Control Zones, as applicable. Tank Heat Options The material tanks should be heated if any of the following functions are needed: Reduced viscosity for better flow or penetration in potted parts Reduced viscosity for faster vacuum degassing Reduced the gel or cure time of the final mixture Reduced viscosity to aid in feeding the metering pump Achieving a consistent temperature where ambient temperature varies and affects mixed material properties Pump Heat Options Heating the pumps is rare. This option should be chosen when the material being pumped crystallizes or becomes highly viscous at or near room temperature. Shroud Heater The shroud heater wraps around the dispense valve to maintaining material temperature through the dispense. 20

21 Twindispense The Twindispense style injection block is used for applications where line pressure is not maintained between cycles. 21

22 Hydracheck Features: Applications requiring dampen (smooth) Dispense Material Flow. Description: The Hydracheck unit consists of an Oil-filled Cylinder, Air Cylinder, Skip Solenoid, Stop Solenoid and Adjustable Needle Valve. When the Air Cylinder Shaft extends, the Shaft will begin to push against the Oil-Filled Piston Rod and the Skip or the Stop Solenoid is actuated, at a rate determined by the Needle Valve setting (approximately when the machine pistons have reached the metering tube openings). Hydraulic fluid is forced through the needle valve in the opposite end of the unit. The Adjustable Needle Valve controls the flow rate of the fluid through this closed-loop circuit. Therefore, the action of the air cylinder piston is completely controlled. Chatter and flutter are eliminated and the Hydracheck compensates for any variation in the power stroke. The Hydracheck unit does not affect the retract half of the machine cycle. Setting Desired set points: The Hydracheck Pressure Regulator is to be set to 65 to 75 PSI (70 typical). This setting is not to be readjusted during the operation. Initially set the Hydracheck Needle Valve adjustment to the Minimum restriction point (Minimum restriction point is a single thread is engaged counter clockwise). Operate the machine, adjusting the Air Pump Pressure to a flow rate higher than the desired Material flow rate. Finally set the Hydracheck Needle Valve adjustment to the desired restriction point creating the desired material flow (Maxim restriction point is all threads are engaged clockwise). Skip Check Function Engaged Utilized in Shot and Operator Control Mode. Smooth Dispensed Material Flow at a consistent rate when External Start is Actuated and Open Dispense Valve Limit Switch is Actuated. Stop Check Function Engaged Utilized in Operator Control Mode only! Mechanically Stop Dispensed Material Flow at Open Dispense Valve Limit Switch point, which then maintains Air Pump Pressure waiting for another External Start. Mechanically Stop Dispensed Material Flow at each point beyond Open Dispense Valve Limit Switch point, which then maintains Air Pump Pressure waiting for another External Start until Retract Limit Switch point is reached. 22

23 Shot Mode 1. Set Pump Mode Retract: On Air Cylinder is Retracted and Extend Limit Switch is Actuated. 2. Set Shot Mode: On Air Cylinder is Retracted and on the Extend Limit Switch point. 3. Set DV Mode Auto: On Dispense Valve is ready to open. 4. External Start is Actuated Air Cylinder moves till Open Dispense Valve Limit Switch point. Skip Check Function is engaged (Dispensed Material Flow based on Hydracheck Needle Valve adjustment set restriction point). Dispense Valve opens. Air Cylinder moves Smooth Dispensing Material at a consistent Flow rate. Air Cylinder moves to the Retract Limit Switch point. Dispense Valve closes. Air Cylinder Retracts to the Extend Limit Switch point. 5. PLC waiting on the next External Start. 23

24 Operator Control Mode 1. Set Pump Mode Retract: On Air Cylinder is Retracted and Extend Limit Switch is Actuated. 2. Set Operator Control Mode: On Air Cylinder is Retracted and on the Extend Limit Switch point. 3. Set DV Mode Auto: On Dispense Valve is ready to open. 4. External Start is Actuated. Air Cylinder moves till Open Dispense Valve Limit Switch point. Skip Check Function is engaged (Dispensed Material Flow based on Hydracheck Needle Valve adjustment set restriction point). Stop Check Function is engaged (Mechanically Stop Dispensed Material Flow and maintains Air Pump Pressure waiting for another External Start). 5a. External Start is Actuated momentary. Dispense Valve opens. Air Cylinder moves Smooth Dispensing Material at a consistent Flow rate. External Start is Actuation is removed. Dispense Valve closes. Skip Check Function is engaged (Dispensed Material Flow based on Hydracheck Needle Valve adjustment set restriction point). Stop Check Function is engaged (Mechanically Stop Dispensed Material Flow and maintains Air Pump Pressure waiting for another External Start). External Start is Actuated momentary (5a. steps) until the Air Cylinder moves to the Retract Limit Switch point. Air Cylinder Retracts to the Extend Limit Switch point. 5b. External Start is Actuated held. Dispense Valve opens. Air Cylinder moves Smooth Dispensing Material at a consistent Flow rate. Skip Check Function is engaged (Dispensed Material Flow based on Hydracheck Needle Valve adjustment set restriction point). Air Cylinder Retracts to the Extend Limit Switch point. Dispense Valve closes. Air Cylinder Retracts to the Extend Limit Switch point. 5b starts over again until External Start is Actuation is removed. NOTE: The Hydracheck can be damaged when running the machine at a high or rapid cycling rates (from low viscosity high air pump pressure), and should be avoided. 24

25 Operating Instructions The Series B171-1 Hydro-Check is a precision-built, adjustable, hydraulic resistance unit designed to provide a smooth controlled feed rate on Bellows Air Motors, Drill Press Feeds and other air or manually operated machine elements. The Series B171-1 Hydro-Check is a single acting unit, available with checking action on either forward or reverse stroke for checking loads up to 1200 pounds. (For checking loads up to 3000 pounds, Series B171-2 and B171-3 may be used.) OPERATING PRINCIPLE: The Hydro-Check consists basically, of a checking cylinder (Item 27), checking piston rod (Item 1), adjustable needle valve (Item 34), and a balance cylinder (Item 43). The checking piston rod may be directly attached or linked to a moving machine part. As the piston rod is pulled out, oil in the checking cylinder is forced, by the moving piston, through the transfer tube, through the needle valve, into the rear end of the checking cylinder. On the return or non-checking stroke, the hydraulic oil returns through the piston valve and the unit is ready for another checking stroke. The balance cylinder assembly (Item 43) automatically compensates for the volumetric displacement of the checking piston rod. An indicator rod (Item 42), attached to the balance cylinder piston, indicates the amount of oil in the Hydro-Check. Three grooves on the indicator rod show when and how much oil should be added to maintain correct hydraulic volume. MOUNTING: The Hydro-Check can be operated in any position provided it is mounted directly inline or parallel to the force it is to control. If unit is mounted parallel, the force or power supply should be guided by ways or guide rods to prevent side strain on the Hydro-Check piston rod. The in-line type of mounting is the most desirable type to use on any application. Series B171-1 Hydro-Checks are available with a threaded piston rod guide and lock nut for nose mounting or pivot brackets and rod clevis for pivot mounting CHECKING STROKE ADJUSTMENT: The mechanical linkage to the element being controlled, moving between two piston rod lock nuts, actuates the Hydro-Check. The point at which checking 25

26 action begins is determined by position of the second lock nut (Item 2) on threaded piston rod. Thus, any portion of the full stroke length may be used for checking. The forward piston rod lock nut is used to lock the second in position. The actuating element engages the first lock nut on return stroke to retract the piston rod. The first or innermost piston rod lock nut (Item 21) must be kept at back end or piston rod thread to prevent Hydro-Check piston from bottoming against rear cylinder head. This nut is locked in position with a socket head set screw. CAUTION: Before applying checking load, be sure stroke of Hydro-Check is long enough to prevent power source from bottoming Hydro-Check piston against front head and possibly damaging Hydro-Check. ADJUSTMENT OF CHECKING RATE: Checking Speed is controlled by turning the knurled needle valve knob (Item 34). Rate is reduced as the knob is turned clockwise and increased as it is turned counter-clockwise. LEVEL: Amount of oil in Hydro-Check is indicated by position of balance cylinder indicator rod (Item 42). The position is determined by grooves on the rod. Proper oil level is indicated when, with threaded piston rod extended, the second indicator groove is flush with balance cylinder head. When threaded piston rod is retracted, the third innermost groove should be flush with cylinder head. Oil should be added when groove nearest end of indicator rod becomes flush with face of balance cylinder head, when threaded piston rod is fully extended. If low, contact Graco customer service. 26

27 Customer Signal This items add a 10 ft (3 m) customer signal interface cable and hardware to initiate a start, and retract, and to indicate ready to dispense and cycle complete conditions. The START signal allows the customer to initiate a start signal by providing a dry contact closure between two designated wires on the cable. The RETRACT signal allows the customer to retract the air cylinder. This stops the pumping action from the dispense valve by providing a dry contact closure between two designated wires on the cable. The READY TO DISPENSE signal provides a contact closure between two designated wires on the cable to indicate that the machine is ready to dispense a metered shot. This signal is only activate in SHOT mode. The CYCLE COMPLETE signal provides a contact closure between two designated wires on the cable to indicate that the machine has completed a metered shot. The closure will be held for one second after the cycle is completed and then it will open. This signal is only active in SHOT mode. 27

28 28

29 Grease Option The grease option provides a grease fitting shaft seal lubricator for selected pumps and the dispense valve. This includes the pump seal housing with grease cavity, grease fitting, and vent fitting. A grease gun and PTFE based grease is provided. A thin film of the material being dispensed is always left on the metering pump shaft as a result of the reciprocating pump motion. This option is used as a preventative maintenance tool to help prevent the material on the shaft from hardening. Hardened or partially cured material accumulated on the pump shaft can cause premature seal failure and can slow or prevent the pump from cycling. A Side Grease Fitting B Side Grease Fitting A Side Overflow B Side Overflow 29

30 Interlock Interlock Switch Outside (PR Model shown) Interlock Switch Inside (PR Model shown) This pump guard cover interlock switch is activated when the pump guard cover is closed. When the pump guard cover is removed, the interlock switch will be deactivated and the PLC output will also be deactivated. The machine will be inoperative at this time. The following HMI screen will be displayed as shown below. To allow the machine to resume operation replace pump guard cover and press the Retract button on the Pump Control screen. 30

31 Technical Data Maximum Ambient Temperature F (43 C) Maximum Operating Temperature F (65 C) Maximum Air Working Pressure psi (0.7 MPa, 7 bar) Maximum Amperage... No-Heat, 120V: 2 Amps No-Heat, 240V: 6 Amps Ratio Range (Depending on metering pistons selected)... 1:1 to 62:1 Shot Size Range (depending on metering pistons selected) to 969 cc Supplied Air Requirements to 2.58 cfm at 80 psi Electrical Requirements /240V, 50/60 Hz, 1 phase 31

32 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. Graco Information For the latest information about Graco products, visit TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Toll Free: or Fax: All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO OHIO INC PORT JACKSON AVE NW, NORTH CANTON, OH Copyright 2009, Graco Ohio Inc. is registered to ISO Revised 06/

Heater Installation Kit

Heater Installation Kit Instructions - Parts Heater Installation Kit 30677B Part No. 248428 Includes parts needed to install VISCON HP heater onto cart. Order VISCON HP heater separately. Important Safety Instructions Read all

More information

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa) Operation Pro Pack Portable Spray Pack - For use with Graco hand-held sprayers (except Fine-Finish sprayers) - - For portable spray applications of water-based and oil-based (mineral spirit-type) architectural

More information

Flat Line Spray Systems Kits

Flat Line Spray Systems Kits Instructions/Parts Flat Line Spray Systems Kits 3A03B EN Heated or non-heated fluid circulation kits for Merkur, Merkur Bellows, and NXT Dura-Flo Pumps. For professional use only. Maximum Fluid Working

More information

Desiccant Air Drying System

Desiccant Air Drying System Instructions - Parts List Desiccant Air Drying System 3099D Model 30 Maximum Operating Pressure 0 psi (. MPa, bar) Maximum Temperature 50 F (5 C) Includes: Part No. Description 30 Stage - Air Filter with

More information

Desiccant Air Drying System

Desiccant Air Drying System Instructions - Parts List Desiccant Air Drying System 30992L EN Model 23440 Maximum Operating Pressure 60 psi (. MPa, bar) Maximum Temperature 50 F (65 C) Model 24M78 Maximum Operating Pressure 75 psi

More information

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure Instructions Parts List Air Dryer 307548H Model 217341 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure Removes oil and other contaminants from compressed air, then dries the air to 45 F

More information

Water-Jacket Heated Hose Kit

Water-Jacket Heated Hose Kit Instructions Water-Jacket Heated Hose Kit 309525H EN Part No. 245866 Includes parts needed to assemble heated hose system. Heated hose assembly and VISCON HP heater must be ordered separately. See Technical

More information

Instructions Parts List

Instructions Parts List Instructions Parts List HYDRAULIC POWERED Agitator 307331F 1500 psi (10.5 MPa, 105 bar) Maximum Hydraulic Input Pressure Model 214853, Series B Mounts on 55 gal (208 liter) drum cover. Read warnings and

More information

AIR DRIVEN Expanding Blade Mixer

AIR DRIVEN Expanding Blade Mixer Instructions/Parts AIR DRIVEN Expanding Blade Mixer 313643B ENG Expanding blade bung-mounted agitator for maintaining suspension and even mixing in industrial paints and coatings. For center bung mounting

More information

Instructions Parts List

Instructions Parts List Instructions Parts List 1 HP (746 W) AIR MOTOR DRIVEN Outboard Agitator 306358G 100 psi (0.7 MPa, 7 bar) Maximum Working Pressure Model 225831, Series B Clamps to side of open 55 gallon drum Important

More information

Instructions Parts List. Table of Contents F. 2.5 HP (1865 W) AIR MOTOR DRIVEN Outboard Agitator

Instructions Parts List. Table of Contents F. 2.5 HP (1865 W) AIR MOTOR DRIVEN Outboard Agitator Instructions Parts List 2.5 HP (1865 W) AIR MOTOR DRIVEN Outboard Agitator 306426F 100 psi (0.7 MPa, 7 bar) Maximum Working Pressure Model 225883, Series B Clamps to side of open 55 gallon drum Important

More information

Booster Heater Upgrade Kit

Booster Heater Upgrade Kit Instructions-Parts Booster Heater Upgrade Kit 332575A EN To install a booster heater on Reactor E-30i Proportioners. For professional use only. Part No. 24T552 Important Safety Instructions Read all warnings

More information

Instructions Parts List

Instructions Parts List Instructions Parts List AIR-DRIVEN, STAINLESS STEEL Agitators 306565H 100 psi (0.7 MPa, 7 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual.

More information

PRO-WASH Gun Washer. Instructions Parts List J. With Husky 307 Pump. Model Model Model

PRO-WASH Gun Washer. Instructions Parts List J. With Husky 307 Pump. Model Model Model Instructions Parts List PRO-WASH Gun Washer 308393J With Husky 307 Pump 100 psi (0.7 MPa, 7 bar) Maximum Working Pressure Read warnings and instructions. See page 2 for List of Models and page 5 for Gun

More information

Fluid Heater. Repair-Parts. Contents D EN

Fluid Heater. Repair-Parts. Contents D EN Repair-Parts Fluid Heater 30D EN For use with Reactor E-0 plural component proportioners. Part No. 4L007 (0V), Series B Part No. 4L008 (40V), Series B 000 psi (4 MPa, 40 bar) Maximum Working Pressure Important

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon Dispenser Package 08666 Rev.C INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 100 psi(6.9 bar) Maximum Air

More information

Compact Twin Flow. Operation - Maintenance B

Compact Twin Flow. Operation - Maintenance B Operation - Maintenance Compact Twin Flow 313549B Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Machine shown may be different from your machine

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum

More information

Instructions/Parts 3A4553E EN. See page 3 for a complete list of model descriptions and part numbers.

Instructions/Parts 3A4553E EN. See page 3 for a complete list of model descriptions and part numbers. Instructions/Parts Electric Direct Drive Agitators 3A4553E EN Low shear, electric, direct drive agitator for mixing and maintaining suspension of industrial coatings stored in fluid tanks. For professional

More information

Air-Driven Agitators. Instructions Parts List. Table of Contents J 3/4 HP (550 W) MOTOR FOR USE WITH WATER-REDUCIBLE FLUIDS

Air-Driven Agitators. Instructions Parts List. Table of Contents J 3/4 HP (550 W) MOTOR FOR USE WITH WATER-REDUCIBLE FLUIDS Instructions Parts List 3/4 HP (550 W) MOTOR Air-Driven Agitators 307154J FOR USE WITH WATER-REDUCIBLE FLUIDS Important Safety Instructions Read all warnings and instructions in this manual. Save these

More information

Predator Proportioners

Predator Proportioners Operation Predator Proportioners 311326A For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres. See page 3 for model information, including maximum working pressure.

More information

Air Driven Agitators

Air Driven Agitators Instructions Parts List Air Driven Agitators 306840N 100 psi (0.7MPa, 7 bar) Maximum Working Pressure Important Safety Information Read all warnings and instructions in this manual. Save these instructions.

More information

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator INSTRUCTIONS PARTS LIST 308 466 KEEP FOR REFERENCE STAINLESS STEEL, PASSIVATED Drum Covers Part No. 37 306 Drum Cover, Series A For President, Monark, Standard, and Fast-Flo Pumps, and 06 758 Agitator

More information

Instructions Parts List

Instructions Parts List Instructions Parts List HEAVY-DUTY STAINLESS STEEL Drum Agitator 308609P Heavy duty, back geared agitator for mixing and maintaining suspension of industrial coatings stored in 55 gallon drums. For professional

More information

Heavy duty, back geared agitator for mixing and maintaining suspension of industrial coatings stored in 55 gallon drums. For professional use only.

Heavy duty, back geared agitator for mixing and maintaining suspension of industrial coatings stored in 55 gallon drums. For professional use only. Instructions Parts List HEAVY-DUTY STAINLESS STEEL Drum Agitator 308609R EN Heavy duty, back geared agitator for mixing and maintaining suspension of industrial coatings stored in 55 gallon drums. For

More information

Hopper or Hose Heat Circulation Kit

Hopper or Hose Heat Circulation Kit Instructions - Parts Hopper or Hose Heat Circulation Kit 33259B ENG For circulating heated water or oil through XM plural-component sprayer double wall hoppers, heated hose, and Viscon HP heater. Approved

More information

Instructions/Parts 3A4548E EN. See page 3 for a complete list of model descriptions and part numbers.

Instructions/Parts 3A4548E EN. See page 3 for a complete list of model descriptions and part numbers. Instructions/Parts Electric Back-Gear Drum Agitators 3A4548E EN Heavy duty, back-geared agitator for mixing and maintaining suspension of industrial coatings stored in 55 gallon drums. For professional

More information

Operation and Parts 3A4032B. only. 100 psi (7.0 bar, 0.7 MPa) Maximum Air Input Pressure. See page 3 for model information.

Operation and Parts 3A4032B. only. 100 psi (7.0 bar, 0.7 MPa) Maximum Air Input Pressure. See page 3 for model information. Operation and Parts Xtreme-Duty Agitator and Packages 3A4032B EN For high-viscosity coatings supplied in 55 gallon (200 liter) open-headed drums. For professional use only. Important Safety Instructions

More information

H-20/35 Pro Proportioner

H-20/35 Pro Proportioner Operation H-20/35 Pro Proportioner 311392C For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres. Important Safety Instructions Read all warnings and instructions in

More information

Double Wall Hopper. Instructions - Parts C

Double Wall Hopper. Instructions - Parts C Instructions - Parts Double Wall Hopper 312747C For use with XM plural-component sprayers and immersion heaters. Only approved for use in explosive atmospheres without the immersion heater. 255963, Double

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

Proportioning Packages

Proportioning Packages Instructions - Parts Proportioning Packages 310794E Complete packages for proportioning, mixing, and spraying 2 component quick setting materials. Important Safety Instructions Read all warnings and instructions

More information

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6 OWNERS MANUAL BOSS COMPRESSED AIR DRYER Distributed by Air & Vacuum Process, Inc. Phone: 281-866-9700 Fax: 281-866-9717 Email: sales@airvacuumprocess.com SAFETY... Page 2 MAINTENANCE... Page 5 INSTALLATION...

More information

Fluid Heater. Repair-Parts. Contents A. Part No (120V) Series A 2000psi (14 MPa, 140 bar) Maximum Working Pressure

Fluid Heater. Repair-Parts. Contents A. Part No (120V) Series A 2000psi (14 MPa, 140 bar) Maximum Working Pressure Repair-Parts Fluid Heater 33445A Used for variable heating of EnergyComplete Spray Foam with Flexible Seal Technology in EnergyComplete Sprayers. Part No. 57 (0V) Series A 000psi (4 MPa, 40 bar) Maximum

More information

Repair B. ThermoLazer Pavement Marking System

Repair B. ThermoLazer Pavement Marking System Repair ThermoLazer Pavement Marking System 313879B - For professional application of thermoplastic traffic marking compound materials (reflective beads applied simultaneously with screeding) - - For outdoor

More information

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate Instructions Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate 332517B EN For adapting a 60# Dyna-Star Pump for use with a 35# bucket. For professional use only. Part No.: Important Safety Instructions

More information

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

Viscon LT Fluid Heater

Viscon LT Fluid Heater Instructions - Parts Viscon LT Fluid Heater 3A2824B EN For variable heating of fluids. Not approved for use in explosive atmospheres or hazardous locations. Model No. 16T525 1750 W; 7.3 A; 240VAC; 50/60Hz,

More information

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. WARNING: Magnetic field hazard. This pump

More information

HH80C HYDRAULIC CRIMP TOOL

HH80C HYDRAULIC CRIMP TOOL HH80C HYDRAULIC CRIMP TOOL DATASHEET SEE PAGE 8 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY INTRODUCTION: The HH80C is a hand actuated hydraulic crimp tool designed

More information

AeroVent 3X Product Manual

AeroVent 3X Product Manual Product Manual AeroVent 3X TABLE OF CONTENTS Precautionary Warning... Page 1 Assembly... Page 2 Assembly Drawing... Page 3 Parts List... Page 3 Operation... Page 4 Maintenance... Page 5 Cobalt Point Replacement...

More information

Dyna-Star HP, HF, 10:1 Pumps: 120# and 400# Drum Cover and Follower Plate

Dyna-Star HP, HF, 10:1 Pumps: 120# and 400# Drum Cover and Follower Plate Instructions Dyna-Star HP, HF, 0: Pumps: 20# and 00# Drum Cover and Follower Plate 278C EN Drum Cover and Follower Plate for use with Dyna-Star 0:, HP, or HF Pumps. For professional use only. To reduce

More information

INSTRUCTION MANUAL HS-229G

INSTRUCTION MANUAL HS-229G INSTRUCTION MANUAL HS-229G 510977 STEP 1 - Where to Install the Thermostatic Steam Trap Determine where to install the thermostatic steam trap based on the following information. a. The trap should be

More information

INSTRUCTIONS PARTS LIST PRO-WASH GUN WASHER

INSTRUCTIONS PARTS LIST PRO-WASH GUN WASHER INSTRUCTIONS PARTS LIST 308 221 This manual contains IMPORTANT S AND INSTRUCTIONS READ AND RETAIN FOR REFERENCE Rev B Supercedes A PRO-WASH GUN WASHER Model 110 484, Series A 100 psi (7 bar) MAXIMUM WORKING

More information

TrueClean ToteCleaner

TrueClean ToteCleaner TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual 8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should

More information

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic) 16 x20 / 15 x15 Air Automatic Heat Transfer Machines OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic) For Customer Service,

More information

XT Series Thermostats

XT Series Thermostats ISO 9001 Explosion-Proof & Moisture Resistant XT Series Thermostats Installation, Operation, & Maintenance Instructions XTWA Thermostat XTWL Thermostat XTB Thermostat Part No.MI133.Rev.2.00 Date of Issue:

More information

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation. Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator

More information

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through

More information

SFD. Suburban Filter Dryer. User Manual Installation Instructions

SFD. Suburban Filter Dryer. User Manual Installation Instructions SFD Suburban Filter Dryer User Manual Installation Instructions Take your air system into the future with patented, molecular sieve technology used in the SFD regenerative cycle compressed air drying system.

More information

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7

More information

Owner s Manual. Terpene Trap CF 1000

Owner s Manual. Terpene Trap CF 1000 Owner s Manual Terpene Trap CF 1000 IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to use your Terpene Trap. For your safety, comply with all safety instructions and

More information

Installation Instructions PP-AS20 Anti-Scale System

Installation Instructions PP-AS20 Anti-Scale System Installation Instructions PP-AS20 Anti-Scale System THIS UNIT MUST BE INSTALLED BY A LICENSED PLUMBER TO VALIDATE THE WARRANTY. COMPONENTS PP-AS20 Filter Housing PP-AS20R Filter Cartridge Installation

More information

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01900 Revision 2 Printed in Canada 1.1 INTRODUCTION Thank you

More information

FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE. CHEMCHAMP MODEL A18 OPERATOR S MANUAL SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP

More information

Disinfectant Boost System DBS-125 Owner's Manual

Disinfectant Boost System DBS-125 Owner's Manual Disinfectant Boost System Owner's Manual www.medoraco.com 866-437 - 8076 info@medoraco.com _Owners_Manual_20180829 Table of Contents Disinfectant Boost System Owner's Manual Table of Contents Safety 1

More information

TrueClean ToteCleaner

TrueClean ToteCleaner TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....

More information

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com MODEL HS115-3, HS115-4 & HS115-5 WIRING

More information

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER Water Tempering Device Installation, Operation, and Maintenance Manual Table of Contents Overview Features Summary...................................... 1

More information

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1 INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01524 Revision 15 Printed in Canada 1.1 INTRODUCTION Thank

More information

AeroVent 1 Product Manual

AeroVent 1 Product Manual Product Manual AeroVent 1 Manual / 4290.0416 TABLE OF CONTENTS Precautionary Warning... Page 1 Assembly.. Page 2 Operation. Page 3 Maintenance Page 4 Parts List... Page 4 Cobalt Point Replacement... Page

More information

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER MODELS SF12-A PICTURED Page 1 of 12 Table of Contents Safety Precautions Section 1. Section 2. Section 3. Section 4. Section 5. Section 6. Systems

More information

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide Installation Manual and Owner s Guide IAQ Series Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application PCOB-09012-0--A - 9" PCO BULB PCOB-14024-0--A - 14" PCO BULB 67202220344 Revised 07-12

More information

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath Thermo NESLAB Manual P/N U00551 Rev. 04/03/00 Instruction and Operation Manual CB-60/CB-80 Cryobath Low Temperature PREFACE Tab able of Contents Compliance...

More information

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron. User Manual Warranty Oliso, Inc. warrants that for a period of one year from the date of the original purchase, this product will be free from defects in material and workmanship, when utilized for normal

More information

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

HW-17 Record Cleaning Machine Setup and Instruction Manual

HW-17 Record Cleaning Machine Setup and Instruction Manual HW-17 Record Cleaning Machine Setup and Instruction Manual VPI Industries, Inc., 77 Cliffwood Ave. #3B, Cliffwood, NJ 07721 Phone: 732-583-6895, Email: Sales@vpiindustries.com http://www.vpiindustries.com

More information

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2 INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2 Publication No. 01906 Revision 0 Printed in Canada 1.1 INTRODUCTION

More information

Model OP155 Air Dryer

Model OP155 Air Dryer "Teamwork & Communication" Model OP155 Air Dryer Operating Manual with Parts Identification OP155-INST June 15, 1998 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive

More information

TUBULAR LLdia-PUMPyy INSTRUCTIONS

TUBULAR LLdia-PUMPyy INSTRUCTIONS TUBULAR LLdia-PUMPyy INSTRUCTIONS MODELS 515 to 547 MODELS 560,562,565 and 567 MATERIAL CODES N3, N5 and N7 ADDENDUM TO OPERATING AND INSTRUCTION MANUAL FOR 500 dia-pumps and FOR 560 dia-puws,these Instructions

More information

R Series B & T2 Model

R Series B & T2 Model FRONT R Series B & T2 Model Fan Forced Wall Heaters 4-1/4 (108mm) NOTE: Knockouts in top same dimensions 3-1/4 3-1/4 (108mm) (108mm) as bottom 16-7/8 (429mm) 13-7/8 (352mm) BOTTOM 13-7/8 (352mm) 7-3/4

More information

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity 100 PPD (2 kg/h) Chlorine or Sulfur Dioxide 250 & 500 PPD (5 & 10 kg/h) Chlorine or Sulfur Dioxide Anti-Siphon Ejector

More information

USER MANUAL SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS USER MANUAL Model: PM50 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067

More information

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual 8 Vanguard Belt Drive Fans Installation and Operators Instruction Manual Thank You The employees of Chore-Time Equipment would like to thank your for your recent Chore-Time purchase. If a problem should

More information

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation. Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator

More information

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY Unpack pump from carton and check for shipping damage. WARNING: Magnetic field hazard. This pump

More information

Therm -O -Flow R Pump Modules

Therm -O -Flow R Pump Modules Instructions -Parts List Therm -O -Flow R Pump Modules 310530R ENG Carbon steel 200 liter (55 gallon) and 20 liter (5 gallon) Pumps For professional use only. (Heated Check-Mate 800) with heaters, insulation,

More information

OPERATING INSTRUCTIONS FUSION MODEL 610 DIGITAL DISPENSING SYSTEM

OPERATING INSTRUCTIONS FUSION MODEL 610 DIGITAL DISPENSING SYSTEM OPERATING INSTRUCTIONS FUSION MODEL 610 DIGITAL DISPENSING SYSTEM 1 FUSION, INC. MODEL 610 PRECISION DISPENSER The Model 610 Dispenser consists of: (1) Dispenser Control Box (2) Foot Pedal Switch (3) Power

More information

AeroVent Standard Product Manual

AeroVent Standard Product Manual Product Manual AeroVent Standard Manual / / 4840.1117 January 2, 2018 Attn: Purchaser s of the Newstripe, AeroVent 1X, 3X or Standard Aerosol Can Recycling units Respirator Required Decal Dear Customer:

More information

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+ Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric

More information

HotPoly Tote Tank / IBC Heaters (TTH Series)

HotPoly Tote Tank / IBC Heaters (TTH Series) HotPoly Tote Tank / IBC Heaters (TTH Series) Instruction Manual Read and understand this material before operating or servicing these heaters. Failure to understand how to safely operate these heaters

More information

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT*** LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS 1. Inspect for damage. *** READ BEFORE OPERATING EQUIPMENT*** 2. Remove all shipping protection: plastic wrapping,

More information

Instruction Manual. Double Candy Apple Cooker

Instruction Manual. Double Candy Apple Cooker Instruction Manual Double Candy Apple Cooker Model No. 4416 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2014 Gold Medal Products Co. Part No. 46841 SAFETY PRECAUTIONS DANGER Machine must be

More information

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ. INSTRUCTION MANUAL Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, Japan Tel: [81]-(0)79-422-1122

More information

SuperKlean Washdown Products

SuperKlean Washdown Products DURAREEL DR8 & DR8S INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** GENERAL WARNINGS High pressure and hot

More information

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO

More information

US 11/2005. Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3. Instruction manual

US 11/2005. Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3. Instruction manual US 11/2005 Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3 Instruction manual The Greens Machine VP-1 and VP-3 Salad & Vegetable Dryer Item Old # New # Description Req. 1 30011 653628 VP-1

More information

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS NOTE - Check with your local water authority for regulations regarding discharge of treated condensate

More information

COMBUSTION AIR SYSTEM

COMBUSTION AIR SYSTEM COMBUSTION AIR SYSTEM MODEL: CAS-2WM WEIL-MCLAIN OUTSIDE AIR KIT FOR USE WITH OIL BURNER MODELS QB-180 & QB-300 4" VRV 4" IAH HOOD AIR BOOT TM The Air Boot model CAS-2WM is for use only on the designated

More information

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

F114 and F115 Ceiling Surface Mounted Media Air Cleaners F114 and F115 Ceiling Surface Mounted Media Air Cleaners FEATURES PRODUCT DATA High Efficiency Particulate AIR (HEPA) filter models are 99.97% efficient and the D.O.P. particle filter models are 95% efficient

More information

Ozone + UV Sanitation

Ozone + UV Sanitation Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW

More information

VP17A BUNN OPERATING & SERVICE MANUAL

VP17A BUNN OPERATING & SERVICE MANUAL BUNN VP17A OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 10860.0001C 9/00 1997 Bunn-O-Matic Corporation

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

H-16.5 Record Cleaning Machine Setup and Instruction Manual

H-16.5 Record Cleaning Machine Setup and Instruction Manual H-16.5 Record Cleaning Machine Setup and Instruction Manual VPI INDUSTRIES, INC., 77 CLIFFWOOD AVE., #3B, CLIFFWOOD, NJ 07721 PHONE: 1-732-583-6895, FAX: 1-732-946-8578 http://www.vpiindustries.com 1 Table

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty IP C 04210000 04211000 04212000 IP S 04203000 04204000 04205000 IP E 04199000 04200000 04201000 IP Trim Sets Valve trim only IP C 04212000 IP E 04201000 IP S 04205000

More information

High-Velocity Floor Fan

High-Velocity Floor Fan High-Velocity Floor Fan Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information