SERIAL # ESPRIT INSTALLATION AND OPERATING INSTRUCTIONS MODEL: ESPR.BODYB SERIES: B ESPRIT ZERO CLEARANCE BALANCED FLUE FIREPLACE

Size: px
Start display at page:

Download "SERIAL # ESPRIT INSTALLATION AND OPERATING INSTRUCTIONS MODEL: ESPR.BODYB SERIES: B ESPRIT ZERO CLEARANCE BALANCED FLUE FIREPLACE"

Transcription

1 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical Switch. Do not use any phone in your building. Immediately call your gas supplier from a neighbour s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier call the fire department. SERIAL # ESPRIT INSTALLATION AND OPERATING INSTRUCTIONS Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance. This appliance is suitable for installation in a bedroom or bed sitting room. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. Gas Safety Certified AS/NZS SAI This appliance is certified for use in Australia with Natural Gas and Liquid Propane Gas. This appliance is certified for use in New Zealand with Natural Gas only. MODEL: ESPR.BODYB SERIES: B ESPRIT ZERO CLEARANCE BALANCED FLUE FIREPLACE ESPRIT

2 Table of Contents Caution... 3 Safety...4 Warnings and Cautions...5 First Fire...7 Operating Instructions...7 Remote Control Operation... 8 System Description... 8 Transmitter (Remote Control with LCD Display).. 8 IFC Module... 9 Operating Procedure... 9 Initializing the System for the first time... 9 Temperature indication Display Turn on the Fireplace Turn off the Fireplace Manual Bypass of the Remote System Key Lock Remote Flame Control...11 Room Thermostat (Transmitter Operation)...11 Smart Thermostat (Transmitter Operation)...11 Comfort Fan Speed Control...12 Continuous Pilot/Intermittent Pilot (CPI/IPI) selection...12 Remote dimmer control (Light)...12 Key Lock Low Battery Power Detection Transmitter Receiver Note regarding Power Failure Lighting Instructions...14 Installing the Esprit...15 Installation Checklist...15 Esprit Dimensions Locating the Fireplace...17 Non combustible Facing Material Installation Clearances to Combustibles Minimum Clearance to Combustible Materials Mantel Clearances Framing and Finishing...21 Floor Installation...21 Mounting Brackets...21 Vent Terminal Minimum Clearances...24 Venting Chart...25 Venting Installing Standoffs Maneuver the Esprit into place Install Venting Gas Connection...27 Gas connection...27 Gas Suppy Gas Pressure Check Gas Pressure Testing Procedure Intake Air Damper Installation Glass Burner Tray Installation...31 Rock Set Installation...34 Log Set Installation...35 Kit Contents...35 Log set installation Door Removal / Installation Surround Installation Instructions LED Light Replacement...41 Pilot Assembly Replacement...42 Accessing the Gas Injector...44 Blower Fan Replacement...45 Propane Conversion...47 Maintenance Glass Door Annual Inspection Periodically Replacement Parts Wiring Diagram Notes...51 LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS/NZS :2017 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions. Must be installed as per AS/NZS Your unit should be serviced annually by an authorized service person. AS/NZS :2017 contains the requirements and methods of compliance for the design, installation and commissioning of gas installations that are associated with the use or intended use of fuel gases such as natural gas, LP gas or biogas ESPRIT

3 Caution FOR YOUR SAFETY - Do not install or operate your Pacific Energy fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Pacific Energy Warranty and may prove hazardous. This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 3.5 kpa. This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 3.5 kpa. Do not use the fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water. This fireplace is equipped with a micro mesh safety screen for your protection and must be installed with the unit. Removal of the safety screen will cause the fireplace to become a burn and fire hazard. ESPRIT

4 Safety A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the Surround Kit component and shall be installed. If the barrier becomes damaged, the barrier shall be replaced with the manufacturers barrier for this appliance. Any grill, panel or door removed for servicing the unit must be replaced prior to operating. It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical Switch. Do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier ESPRIT

5 Warnings and Cautions DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT S IN OPERATION. DO NOT USE OR STORE FLAMMABLE MATERIALS IN OR NEAR THIS APPLIANCE. DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. DO NOT MODIFY THIS APPLIANCE. WARNING SHOCK HAZARD. CAN CAUSE SEVERE INJURY OR DEATH. THIS DEVICE IS POWERED BY LINE VOLTAGE. DO NOT TRY TO REPAIR THIS DEVICE. IN NO WAY IS THE ENCLOSURE TO BE TAMPERED WITH OR OPENED. DISCONNECT FROM LINE VOLTAGE BEFORE PERFORMING ANY MAINTENANCE. DUE TO HIGH TEMPERATURES, THIS GAS APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSICAL BARRIER IS RECOMMENDED IF THERE ARE AT RISK INDIVIDUALS IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. THE GUARD IS FITTED TO THIS APPLIANCE TO REDUCE THE RISK OF FIRE OR INJURY FROM BURNS AND NO PART OF IT SHOULD BE PERMANENTLY REMOVED. FOR PROTECTION OF YOUNG CHILDREN OR THE INFIRM, A SECONDARY GUARD IS DO NO INSTALL IN A FIREPLACE. ESPRIT

6 WARNING FIRE HAZARD. CAN CAUSE SEVERE INJURY OR DEATH. THE RECEIVER CAUSES IGNITION OF THE APPLIANCE. THE APPLIANCE CAN TURN ON SUDDENLY. KEEP AWAY FROM THE APPLIANCE BURNER WHEN OPERATING THE REMOTE SYSTEM OR ACTIVATING MANUAL BYPASS OF THE REMOTE SYSTEM. INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN. THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE. Congratulations on your purchase of a Pacific Energy Gas Appliance. Your fireplace has been professionally installed by: Dealer name: Phone Number: If you discover any problems with your gas appliance contact your dealer immediately to have the unit repaired. Caution: Do not attempt to repair the fireplace because you may cause injury to yourself or others, and risk causing damage to the unit. Before operating your appliance carefully read this manual and pay close attention to all Safety Warnings. The manual contains important information on the unit s safe operation and maintenance ESPRIT

7 First Fire When lit for the first time, the fireplace will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants, gaskets, and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate the area. Odour caused by the curing process may cause discomfort to some individuals. It is normal for fireplaces fabricated from steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or cook stove oven. Operating Instructions Warning: The home owner must not make any adjustments to the Esprit other than what can be achieved by using the remote handset (Figure 1) and the settings control / battery holder located at the bottom of the surround backing plate (Figure 4). Any other adjustments must be performed by a qualified service technician. Before operating this appliance, proceed through the following checklist. 1. Read and understand these instructions before operating this appliance. 2. Check to see that all wiring is correct and enclosed to prevent possible shock. 3. Check to ensure that there are no gas leaks. 4. Make sure that the glass door is in place. Never operate the appliance with the glass door removed. 5. Verify that all flueing and the termination cap is unobstructed. 6. Verify log placement. 7. When lighting the appliance, the inside of the glass may fog up. This will burn off after a few minutes of operation. NOTE: After 3 failed attempts to ignite, the fireplace will enter a 1 minute hibernation period before attempting to ignite again. NOTE: Fireplace may take up to 30 seconds to ignite each time the ON button has been selected. ESPRIT

8 System Description The Proflame 2 Remote Control System consists of two elements: 1. Proflame2 Transmitter. Remote Control Operation 2. Proflame2 Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the gas valve and stepper motor. Transmitter (Remote Control with LCD Display) The Proflame 2 Transmitter uses a streamline design with a simple button layout and informative LCD display Figure 1. The transmitter is powered by 3 AAA type batteries. A Mode key is provided to Index between the features and a Thermostat key is used to turn on/off or index through thermostat functions (Figure 1 and Figure 2). Blue back lit LCD display ON/OFF Key THERMOSTAT Key UP/DOWN Arrow Key MODE Key Figure 1: Proflame 2 handset. TRANSMISSION THERMOSTAT OFF/ ON/SMART SET POINT: TEMPERATURE/LEVEL/STATE OFF ON SMART KEY LOCK LOW BATTERY ALARM ROOM TEMPERATURE CPI MODE FLAME LEVEL COMFORT FAN MAX DIMMER Figure 2: Proflame 2 LCD display ESPRIT

9 IFC Module The Proflame 2 Integrated Fireplace Control (IFC) module (Figure 3) is a device that allows automatic ignition and pilot flame supervision, and commands the functions of the hearth Fireplace. It s configured to control the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition) modes. The Proflame2 IFC module controls and connects directly to the pilot assembly and the automatic valve using low electric power. The IFC module can be powered by both an AC power supply, and battery pack for back up. The Proflame 2 offers the added ability to control the comfort fan speed from OFF through six (6) speeds. The external batteries can provide DC power to the IFC allowing the batteries to be used only when line power is interrupted or lost. Operating Procedure Initializing the System for the first time 1. Remove the Front panel if not already removed. Remove the battery cover and install 4 AA batteries into the battery holder (Figure 4). Install the ON/OFF switch cover over top of the battery holder. Make sure that the selection switch is on the Remote (middle) setting. 2. Install 3 AAA batteries into the Proflame2 Remote Transmitter (Figure 1). 3. Energize the electrical power to the fireplace and open the gas supply line. 4. Insert a straightened paper clip into the opening marked PRG of the ON/OFF battery holder cover (Figure 4) and press the program button once. The module will beep 3 times indicating that it is ready to synchronize with a remote transmitter. 5. On the remote transmitter, push the power on button once. The remote transmitter will beep 4 times to indicate that the remote transmitter and the control module are now synchronized. The remote transmitter is now ready to use. Figure 3: IFC module. Figure 4: Battery holder - manual controls. ESPRIT

10 Temperature indication Display With the system in the OFF position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of the Room Temperature display (Figure 5 or Figure 6). Turn on the Fireplace With the system OFF, press the ON/OFF Key on the remote transmitter. The remote transmitter display will show some other active Icons on the screen. At the same time the Receiver will activate the Heater. A single beep from the Receiver (module) will confirm reception of the command. Figure 5: Display in Fahrenheit. Turn off the Fireplace With the system ON, press the ON/OFF Key on the Remote transmitter. The Remote transmitter LCD display will only show the room temperature (Figure 5 or Figure 6). At the same time the Receiver (module) will turn off the Heater. A single beep from the Receiver confirms reception of the command. Figure 6: Display in Celsius. Manual Bypass of the Remote System If the batteries of the receiver or remote transmitter are low or depleted, the Heater can be turned off manually using ON/ OFF switch located on battery box. This will bypass the remote transmitter. Key Lock This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP keys at the same time. The lock icon will appear (Figure 7). To de-activate this function, press the MODE and UP keys at the same time. Figure 7: Key lock ESPRIT

11 Remote Flame Control The Proflame 2 has six (6) flame levels. With the system turned on, and the flame level at maximum in the Fireplace, press the down arrow key once to reduce the flame height by one step until the flame is turned off. The up arrow key will increase the flame height each time it is pressed. If the up arrow key is pressed while the system is on but the flame is off, the flame will come on in the high position (Figure 8). A single beep will confirm reception of the command. Flame level Max Flame level 5 Room Thermostat (Transmitter Operation) Flame level 1 Flame Off Figure 8: Flame level control. The remote control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in a room. To activate this function, press the thermostat key (Figure 1). The LCD display on the remote transmitter will change to show that the room thermostat is ON and the set temperature is now displayed (Figure 9). To adjust the set point, press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the remote transmitter. Smart Thermostat (Transmitter Operation) The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point and the room temperatures. As the room temperature gets closer to the set point, the Smart Function will modulate the flame down. If the room temperature is cool the Smart function will modulate the flame up. To activate this function, press the THERMOSTAT key (Figure 1) until the word SMART appears to the right of the temperature bulb graphic (Figure 10). To adjust the set point, press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the remote transmitter (Figure 11). Figure 9: Room temperature control. Figure 10: Smart flame control. Figure 11: Smart flame function set low. ESPRIT

12 Comfort Fan Speed Control If the fireplace is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key (Figure 1) to index to the fan control icon (Figure 12). Use the Up/Down Arrow Keys to turn on, off or adjust the fan speed. A single beep will confirm reception of the command. Figure 12: Comfort fan control. Continuous Pilot/Intermittent Pilot (CPI/IPI) selection With the system in OFF position press the Mode Key (Figure 1) to index to the CPI mode icon (Figure 13). Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode (CPI). Pressing the Down Arrow Key will return to IPI. A single beep will confirm the reception of the command. Remote dimmer control (Light) Figure 13: IPI CPI Selection. The auxiliary function controls the AUX power outlet by the dimmable light control. To activate this function use the Mode Key (Figure 1) to index to the light bulb icon (Figure 14). The intensity of the output can be adjusted through six (6) levels. Use the Up/Down Arrow Keys adjust the output level. A single beep will confirm reception of the command. Figure 14: Dimmer light control ESPRIT

13 Key Lock This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP keys at the same time (Figure 1). The lock icon will appear (Figure 15). To de-activate this function, press the MODE and UP key at the same time. Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (Figure 16) before all battery power is lost. When the batteries are replaced this Icon will disappear. Receiver The life span of the IFC batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance and the number of changes to the room thermostat set point, etc. When the IFC batteries are low, a double-beep will be emitted from the IFC board when it receives a command from the transmitter. This is an alert for a low battery condition for the IFC board. When the batteries are replaced the beep will be emitted from the IFC board when a key is pressed. See Initializing the System for the first time on page 9. Figure 15: Lock icon. Figure 16: Low battery icon. Note regarding Power Failure This fireplace has a battery backup in case of a power outage. In the event of a power outage, the Esprit will continue to operate for as long as the batteries last, usually up to a couple of weeks. The batteries will not operate the blower fan or the lights while the power outage lasts. A tip for helping the batteries to last longer is to not continually adjust the hight of the flame as the valve motor will be activated each time a new flame level is selected and thus draw power from the batteries. ESPRIT

14 Lighting Instructions ESPRIT

15 Installing the Esprit Installation Checklist 1. Uncrate the Esprit. Examine for shipping damage and that the shipping list is complete. 2. Review the following: Esprit dimensions (page 16). Locating the Fireplace (page 17). Clearances to combustibles (page 19). Mantel clearance (page 20). Framing and finishing requirements (page 21). Vent Terminal Minimum Clearances (page 24). Venting chart (page 25). 3. Maneuver the Esprit into place (page 26). 4. Install venting (page 26). 5. Make gas connections (page 27). 6. Plug electrical connection into receptacle. 7. Gas pressure check (page 28). 8. Gas pressure testing procedure (page 29). 9. Complete finishing. See Non combustible Facing Material Installation on page Panel set installation (page 31). 11. Vent Damper installation (page 30). 12. Glass or log set installation (page 31 and page 35). 13. Door installation (page 39). 14. Install surround and front covers (page 40). 15. Install backup batteries and link the hand transmitter to the Esprit (page 9). 16. Final check Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to the customer. This includes: If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for minutes to stabilize. Installing the Vent Dampers if flame is too hectic. Caution: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer. ESPRIT

16 Esprit Dimensions 304mm 172mm 876mm Top view 230mm 876mm 742mm 485.5mm 842mm 666mm 1020mm 1108mm Front view Adjustable 55-70mm 398mm 415mm Side view Figure 17: Esprit dimensions. Contemporary Surround 572 mm Figure 18: Surround dimensions. 41 mm 1073 mm ESPRIT

17 Locating the Fireplace In planning the installation for the fireplace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed. Various installations are possible, such as, into an existing wall, a corner, a built in wall or a wall projection. Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. For places where a second side wall is specified, fireplace should be accessible for service Figure 19: Common installation options. ESPRIT

18 Important Note: Non combustible Facing Material Installation Prior to installation of non-combustible materials by others, check and inspect carefully for any hairline cracks and / or damage to board. The non-combustible board must be a minimum of 12 mm thick and comply with AS and AS Material which is thinner may crack as a result due to the high temperatures this appliance emits. 1. Use screws for use with non-combustible boards: Secure non-combustible material around unit and framing. Important Note: To avoid cracking the board, pre-drill holes prior to securing to unit or framing. 2. Wipe any debris/dust from the non-combustible material and dry wall. 3. Prior to securing, it is mandatory to prime the facing and edges using a quality primer. This will ensure proper adhesion of the tape, filler and paint. Failure to follow this procedure will result in cracked seams. 4. Tape the seams using a mesh type tape. 5. Fill seams as normal. Avoid using filler which shrinks excessively. Filler must be cured as per manufacturers recommendations. 6. Prime wall for a second time for proper adhesion of paint. 7. Paint walls using a high quality paint which will withstand the high temperatures of 200 C being emitted from this appliance. Note: When applying 12mm minimum non-combustible board to framework, it is advisable to use the same 12mm minimum non-combustible board on the whole front face of the wall. When using a standard fascia, cut out the clean edge trim opening plus a further 10mm border. When using a 15mm finishing trim, cut out the clean edge trim opening plus a further 4mm border. When using painted 12mm minimum non-combustible board as finished wall surface, use 15mm finishing trim. When using clean edge trim, do not seal fireplace to finished wall material. The above will allow for possible expansion and contraction ESPRIT

19 Clearances to Combustibles 915 mm minimum 12mm min. thick non combustible material in this zone only 610mm Min. 915 mm Min. Contemporary Surround Top of glass (Reference point) Figure 20: Minimum distance from top of the glass to top. Floor Figure 21: Side view clearances. Front of the appliance is an open side of the combustion chamber covered with the glass. Minimum Clearance to Combustible Materials ENCLOSED SIDE WALL 0 mm From side standoffs ENCLOSED BACK WALL 0 mm ENCLOSED TOP 0 mm From top standoffs EXPOSED SIDE WALL 203 mm From edge of glass EXPOSED CORNER WALL 50 mm FLUE 2.54 mm MANTEL 915 mm min. From top edge of glass. BOTTOM OF UNIT 0 mm ESPRIT

20 Mantel Clearances Combustible material 12mm thick non-combustible board 305mm Mantel 915 mm min. from edge of glass ESPRIT

21 Installation of the Esprit Fireplace and electrical and gas connections must conform to the requirements of The joint Australian/New Zealand standards AS/NZS 5601 and to local codes. Floor Installation It is permissible to install the Esprit directly on a floor provided it is a solid surface. There is no requirement for a hearth to be installed in front of the fireplace. Mounting Brackets Framing and Finishing Four mounting brackets are included with the Esprit. Loosen the screws indicated in Figure 22 and Figure 23. The mounting brackets will secure the Esprit to the framing. The Esprit must be installed so that the floor of the fireplace is elevated a minimum of 29mm from the room floor. Minimum 12mm thick non-combustible board or material must cover the front of the Esprit a minimum of 610mm above the glass door. A mantel (or ceiling) must be a minimum of 915 mm above the glass door. A mantel should extend no more than 305mm from the front wall. Loosen these screws Loosen these screws Figure 22: Top mounting bracket location. Figure 23: Bottom mounting bracket location. Figure 24: Mounting bracket - side view. Figure 25: Mounting brackets in place. ESPRIT

22 1108mm 842mm Figure 26: Framing dimensions. 12mm min. thick non-combustible board 610 mm Minimum 1108 mm 842 mm Combustible Figure 27: Framing and finishing dimensions ESPRIT

23 12mm min. thick non-combustible board 915mm min width non-combustible board 610 mm Minimum Combustible 842 mm Figure 28: Framing at the corner. 530mm 1385mm 50mm Minimum clearance Figure 29: Minimum clearance corner framing. ESPRIT

24 Vent Terminal Minimum Clearances a j h T c f c n openable window I k j door j h h T g e P e d M d b g See note 3 T k See note 2 T = Flue terminal M = Gas meter Shading indicates prohibited I = Mechanical air inlet P = Electricity meter or fuse box areas for flue terminals a - Below eaves, balconies or other projections: MIN. CLEARANCE (mm) Appliances up to 50 MJ/h input Appliances over 50 MJ/h input b - From the ground or above a balcony c - From a return wall or external corner d - From a gas meter (M) e - From an electricity meter or fuse box (P) f - From a drain or soil pipe g - Horizontally from any building structure (unless appliance approved for closer installation) or obstruction facing a terminal h - From any other flue terminal, cowl, or combustion air intake j - Horizontally from an openable window, door, non-mechanical air inlet, or any other opening into a building, with the exception of sub-floor ventilation: Appliances up to 150 MJ/h input Appliances over 150 MJ/h input k - From a mechanical air inlet, including a spa blower n - Vertically below an openable window, non-mechanical air inlet or any other opening into a building, with the exception of... See table sub-floor ventilation...below CLEARANCE n (mm) Space Heaters All other appliances Up to 50 MJ/h input Up to 50 MJ/h input Over 50 MJ/h & up to 150 MJ/h Over 150 MJ/h input NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter or fuse box extends to ground level. 3. See clause for restrictions on a flue terminal under a roofed area. 4. See Appendix J, Figure J1(a) and J2(a) for clearances required from a flue terminal to a LP Gas cylinder. A fl ue terminal is considered to be a source of ignition. Figure 3.4 MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES ESPRIT

25 10980 mm mm mm mm 9760 mm 9455 mm 9150 mm 8845 mm 8540 mm 8235 mm 7930 mm 7625 mm 7320 mm 7015 mm 6710 mm 6405 m m 6100 mm 5795 mm 5490 mm 5185 mm 4880 mm 4575 mm 4270 mm 3965 mm 3660 mm 3355 mm 3050 mm 2745 mm 2440 mm 2135 mm 1830 mm 1525 mm 1220 mm 915 mm 610 mm 305 mm mm 3660 mm 3355 mm 3050 mm 2745 mm 2440 mm 2135 mm 1830 mm 1525 mm 1220 mm 915 mm 610 mm Venting Chart No venting options Venting envelope Venting envelope No venting options 6405 mm 6100 mm 5795 mm 5490 mm 5185 mm 4880 mm 4575 mm 4270 mm 3965 mm Exhaust Damper Position To Vertical Run Chart Install Damper Do Not Install Damper Do not use an unlined masonry chimney as the flue for this appliance Note: The vent must not exceed a total length of mm. Any combination of rise and run may be used but must be constrained to the boundaries of this chart. A Maximum of three 90 elbows may be used. Only one (1) 90 elbow or combination of other elbows equaling 90 can be used without reducing horizontal run. For each additional 90 elbow, or an equal combination of elbows, reduce horizontal vent run by 610 mm. Ensure vent pipe is properly supported. Note: The intake damper positions specified in this chart were set in a controlled testing environment, and serve as a general guideline for installations. Every venting configuration is different, and the damper setting may need slight adjustment from this chart. ESPRIT

26 Venting 46DVA-HSC Horizontal Terminal 46DVA-VCH Vertical Terminal This fireplace is certified for use with 101.6mm x mm coaxial venting components only. It is permitted to only use Duravent certified venting for this appliance. Standoffs Figure 30: Standoff. Figure 31: Standoff on fireplace top. This unit comes with two standoffs (Figure 30,31) on the top of the fireplace. Maneuver the Esprit into place The appliance must be installed on a flat, solid, continuous surface. For example, a wood, metal or concrete floor or in a raised (on the wall) application. The appliance must be installed on concrete or a metal or wood panel extending the full width and depth of the appliance. Install Venting This gas fireplace and venting system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use its own separate venting system ESPRIT

27 Gas Connection Open Shut Figure 32: Connecting gas line. Figure 33: Gas flow tap. Gas connection To make the required electrical and gas connections, start by positioning the gas fireplace. Connect the gas supply line to the 3/8 BSPT fitting that located on a shut off valve bracket as seen in Figure 32. A gas shut off tap is located inside the fireplace and may be accessed by removing the surround, screen and front. Please see the gas supply section for requirements of the gas supply. Servicing of the appliance can be performed from the front of the unit. Caution: The gas line should be installed by a qualified service person in accordance with all building codes. This section is intended as a guide for qualified technicians installing this appliance. Consult local and/or national building codes before proceeding. Gas supply line connection is located on the right side of the fireplace. Gas connection accepts a 3/8 BSPT fitting. Correct gas line diameter must be used to assure proper operation and pressure. The fireplace input rating is shown in the chart on page 28. A drip leg must be installed in the gas supply line going to the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve. Check local codes for additional requirements. Turn on the gas supply and check that all connections are tight and leak free. ESPRIT

28 Servicing of the appliance can be performed from the front of the unit by removing the door and the gas tray from the unit. Caution: The gas line should be installed by a qualified service person in accordance with all building codes. This section is intended as a guide for qualified technicians installing this appliance. Consult local and/or national building codes before proceeding. Gas supply line connection is located on the side of the fireplace. Gas connection accepts a ½ NPT fitting. Correct gas line diameter must be used to assure proper operation and pressure. The fireplace input rating is shown in the chart below. A drip leg must be installed in the gas supply line going to the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve. Check local codes for additional requirements. Gas Suppy Turn on the gas supply and check that all connections are tight and leak free. Gas Pressure Check Please refer to Gas Pressure Testing Procedure on page 29 for gas pressure testing procedure. Esprit: 240 Vac, 0.72 amp, kw Gas Type Injector (mm) Min / Max (MJ/hr) Manifold Pressure (kpa) Inlet Pressure (kpa) Natural Gas / Propane / ESPRIT

29 Gas Pressure Testing Procedure Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point screws. Verify gas pressures with the fireplace lit and at the highest setting. 1. Remove window surround and locate the valve. 2. Locate the inlet and outlet test ports on the valve which can be seen in Figure 34. After locating test ports loosen the screws within the ports using a flat-tip screwdriver. 3. Attach pressure gauge to the test ports 4. Turn gas supply back on and test pressures. 5. After testing is finished turn off gas supply, remove the pressure gauges and tighten up the screws in the test points. PILOT ADJUSTMENT SCREW MAIN GAS SOLENOID PILOT SOLENOID PRESSURE MODULATOR DEVICE Figure 34: Gas control valve. MANIFOLD PRESSURE TEST POINT INLET PRESSURE TEST POINT ESPRIT

30 Intake Air Damper Installation The Esprit fireplaces come with the damper that can limit the flow of intake air. This damper is located behind the air baffle at the top of the firebox. Sometimes on installations that involve vertical venting configurations over 701 cm in height, the intake air tends to accelerate down the vent causing hectic flame action. This damper has to be closed to reduce the speed of the intake air and thus calm the flames for a more natural look. See (page 25) to check if damper required for installation. Damper Damper Figure 35: Air damper location. Figure 36: Damper detail ESPRIT

31 Glass Burner Tray Installation Figure 37: Glass burner tray. Installation 1. Insert the glass burner tray (Figure 38) into the firebox. Take note of the cut out for the pilot assembly and orient the tray so that the air flow ports are facing up. The edges of these ports will prevent the glass media from falling down into the firebox. Secure the tray to the ledges on all four sides of the firebox with the supplied screws (Figure 39). Figure 38: Inserting glass media tray. Figure 39: Securing glass media tray to firebox floor. ESPRIT

32 2. Insert the burner into the glass media tray and secure with 6 supplied screws (Figure 40 and Figure 41). 3. Once the burner is seated and secured, adjust the venturi air shutter, located under the firebox floor, as follows: for natural gas, keep the setting on the right side of the adjustment slot (Figure 42). For propane gas, keep the setting on the left side of the slot (Figure 43). Further venturi adjustment can be easily made later once the Esprit is lit. 4. Place the pilot shield over the pilot assembly and into the cut out of the glass media tray (Figure 45). Be sure to push the shield down far enough so that the pilot flame is able to reach the burner without being impeded by the shield wall itself. Figure 40: Insertion of burner. Figure 41: Securing burner to burner tray. Figure 42: Initial venturi setting for natural gas. Figure 43: Initial venturi setting for propane gas ESPRIT

33 5. Spread glass media evenly over the surface of the burner tray. Use as much glass media as is needed to fully cover the burner tray but not so much that the glass media spills over into the air flow ports (Figure 46). Figure 44: Pilot assembly shield. Figure 45: Pilot assembly shield installed. Figure 46: Glass media installation. ESPRIT

34 Rock Installation To install the optional rock set, simply place desired number of rocks into the fireplace pan as seen in Figure 48 making sure no rocks are in the flame when the unit is operating. Figure 47: Glass media. Figure 48: Rock set installation ESPRIT

35 Optional Log Set Installation Kit Contents Log number 1 Log number 2 Log number 3 Log number 4 Log number 5 Log number 6 Log numbers 7 & 8 Figure 49: Esprit log set. Figure 50: Ember material. ESPRIT

36 Log set installation Figure 51: Ember material spread evenly over burner tray. 1. Spread ember material evenly over the surface of the burner tray. Use as much ember material as is needed to fully cover the burner tray but not so much that the ember material spills over into the air flow ports (Figure 51). Figure 52: Log number 1 position. Figure 53: Log number 2 position. 1. Place log number one into the left hand corner of the firebox. The back of the log should be up against the rear panel and positioned in such a way so that it is stable and so that it does not cover the air vent port (Figure 52). 2. Position log number two so that its left side is supported by log number one and so that the post on the right side is vertical (Figure 53) ESPRIT

37 Figure 54: Log number 3 position. Figure 55: Log number 4 position. 3. Log number three has a hole which is to fit over the post in log number two. The right end of this log is to point toward the right hand side panel (Figure 54). 4. Position log number four so that its thicker end is touching the left side panel (Figure 55). Make sure that this log is forward enough so that none of the air vent ports behind it are being blocked. 5. Log number five is to be positioned as shown in Figure 56. As with log number four, make sure that this log is forward enough so that the air vent ports located behind it are not blocked. 6. Place log number six so that its pointed end rests on top of log number four while its other end extends back towards log number two (Figure 57). Be sure that this log does not cover any of the air vent ports. 7. Logs number seven and eight are identical. Place one at either end of the firebox as desired (Figure 58 and Figure 59). Figure 56: Log number 5 position. Figure 57: Log number 6 position. ESPRIT

38 Figure 58: Log number 7 position. Figure 59: Log number 8 position. Figure 60: Completed log placement ESPRIT

39 Door Removal / Installation Removal 1. Hold the door. Pull 3 levers to release the door. 2. Lift the door up to release it from the slot on the bottom of the firebox. Installation 3. Place the door in the slot at the bottom of the firebox opening. Push 3 levers at the top of the door to secure the door. Door levers Figure 61: Door handles. ESPRIT

40 Installation Surround Installation Instructions 1. Remove front and screen from surround. 2. Position the surround so that the battery pack is at the bottom (Figure 62). Plug the battery pack connector into the back of the battery pack (Figure 64). 3. Fasten the surround base to the fireplace using supplied screws and mounting holes located along the inner edge of the base (Figure 65). 4. Install screen panel in slots on inner side of the surround base (Figure 66). 5. Install the surround front (Figure 67) by positioning it so as to clear the notches and secure by applying downward pressure in order to engage the locking tabs. Figure 62: Surround with battery pack. Figure 63: Battery pack and manual controls. Figure 64: Connecting the battery pack. Figure 65: One of 4 attaching points on the surround. Figure 66: Screen panel. Figure 67: Front cover with protective film ESPRIT

41 LED Light Replacement The LED lights assembly can be replaced by removing the glass door. It is not necessary to remove the surround and front and screen but the extra room that will become available once the surround and front is removed will make accessing the assembly easier (Figure 69). To Remove: 1. Two screws hold the assembly to the ceiling of the firebox (Figure 68), once the screws are removed, the shield will separate from the rest of the assembly. 2. Gently pull the assembly down from the ceiling. There will be some resistance when pulling the assembly because the light assembly is surrounded by insulation. The connector may become hung up in the insulation while trying to maneuver the assembly out but with a little effort, the assembly will come out. 3. Disconnect the LED assembly and plug the replacement assembly in to the connector. 4. Gently return the assembly to its place inside the firebox ceiling. Reattach the assembly and the shield using the previously removed screws. Figure 68: View of LED light from inside of the firebox. Insulating gasket LED Lights Shield Figure 70: LED light assembly. Figure 69: LED lights location. ESPRIT

42 Pilot Assembly Replacement 1. Remove the front, screen panel and the surround backing. Disconnect the connector from the battery holder/receiver from the surround backing. This will expose the area beneath the firebox floor. See Surround Installation Instructions on page 40 and follow the directions in reverse order to remove. 2. Close the electrical supply. Shut the gas valve, see Figure 33: Gas flow tap. on page Remove the glass door. See Door Removal / Installation on page Remove the log set and ember material or the glass media - whichever is installed. 5. Remove 2 screws that attaches the control module caddy from its bracket (Figure 71). Remove the control module along with its caddy. 6. Rotate the control module and caddy so that the igniter and rectifier connectors (X2 & X3) are able to be disconnected (Figure 72). Disconnect red and black leads. X3 (Red) X2 (Black) Figure 71: Remove control module caddy. Figure 72: Disconnect leads to pilot assembly. Figure 73: Pilot gas supply line connector. Figure 74: Releasing pilot gas line from gas valve ESPRIT

43 7. Locate the pilot assembly (Figure 73). 8. Unscrew the pilot gas supply line using a 7/16 (11 or 12 mm) wrench (Figure 74). 9. Remove two screws from holding the Pilot Assembly to the firebox floor (Figure 75). 10. Extract the old pilot assembly and install replacement assembly (Figure 76). 11. When reinstalling the igniter and rectifier leads, be sure to refer to the wiring diagram printed on the control module (Figure 77) before connecting the leads. Figure 75: Pilot assembly screws. Figure 76: Pilot. X2 (Black) X3 (Red) Figure 77: Igniter and rectifier wiring. ESPRIT

44 To expose the gas injector: Accessing the Gas Injector 1. Remove the front, screen panel and surround to expose the display media, electronics and gas components. Be sure to unplug the connector to the back of the battery pack on the surround. 2. If already installed, remove the log set, ember material and burner, or glass media, glass tray and burner. 3. Locate the venturi adjustment screw under the firebox floor (Figure 94). Loosen it and move it to the right to allow for access to the injector using a 1/2 (or 13 mm) socket and extension. 4. Using the 1/2 (or 13 mm) socket, remove the injector. 5. Spread a small amount of thread sealant onto the threads of the replacement injector and install using the 1/2 (or 13 mm) socket (Figure 80). 6. Return the venturi to the desired setting. LP NG Figure 78: Access to injector. Figure 79: Venturi air shutter adjustment screw. Figure 80: Inserting replacement injector ESPRIT

45 Blower Fan Removal Blower Fan Replacement To access and remove the blower fans, the firebox floor must be removed: 1. Remove the front, screen panel and the surround backing. Disconnect the connector from the battery holder from the surround backing. This will expose the area beneath the firebox floor. See Surround Installation Instructions on page 40 and follow the directions in reverse order to remove. 2. Close the electrical supply. Shut the gas valve, see Figure 33: Gas flow tap. on page Disconnect the lights wiring leads (Figure 81). This will allow the firebox floor to be completely removed. Figure 81: Disconnect leads to lights. 4. Remove the glass door. 5. Remove the log set and ember material or the glass media - whichever is installed. 6. Remove the upper baffle (page 32). 7. Remove the porcelain panels. 8. Remove the firebox floor screws from the perimeter of the firebox floor (Figure 82). ESPRIT

46 Figure 82: Firebox floor with panels removed. Figure 83: Firebox floor partially removed. 9. Lift the floor part way out of the fireplace until the electrical connectors for the blower fans can be accessed (Figure 83). Disconnect the blower wiring leads and completely remove the firebox floor from the fireplace. 10. Each blower fan is affixed to the rear wall by two 7/16 nuts. Completely remove the two inside nuts and loosen the two outside nuts (Figure 84). 11. Remove the blower fan(s). Securing nuts Figure 84: Blower fans securing nut location. Figure 85: Blower fans released from rear wall ESPRIT

47 Propane Conversion Before starting the conversion make sure to shut off the gas supply to the unit and allow fireplace to cool to room temperature. To convert the gas fireplace from natural gas to propane, a kit is required. This kit comes with new pilot and burner orifices as well as a new pressure modulator for the valve. Pilot assembly Venturi air shutter Orifice To switch the pressure modulator, follow the instructions that are provided with the conversion kit. To change the orifices you are required to remove the door, media set, and burner. Please refer to the appropriate sections of this manual and follow instructions on how to correctly remove the components. Figure 86: Pilot, orifice and air shutter. After removing the burner you will have access to the burner orifice which is located on the bottom of the burner tray (Figure 86). The orifice can be removed using a ½ inch socket. Before installing the new orifice, thread sealant needs to be applied to the threads of the new orifice to ensure a proper seal when installed. To replace the pilot orifice you will need to remove the pilot hood which is held in place by a spring. First remove the spring, and then remove the hood by pulling it up from the pilot bracket (Figure 87). To remove the existing orifice insert a 4mm Allen wrench into the hexagonal key-way of the orifice and rotate counterclockwise until free. Insert the new orifice using the same Allen wrench and tighten it until a torque of Nm (9 lbf) is achieved. Replace the pilot hood by aligning the tab on the base of the hood with the slot in the side of the pilot journal, and push the hood down onto the pilot bracket. Replace the spring by pushing it onto its seat. Before returning the burner into position, the venturi shutter will have to be adjusted to the correct opening. The correct venturi settings are shown in Figure 88. Loosen the screw and slide the shutter. Tighten the screw, and return the burner into position. Further adjustment may be necessary. Figure 87: Pilot hood removal. LP NG Figure 88: Venturi air shutter adjustment. ESPRIT

48 Maintenance Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fireplace and its venting should be inspected at least once a year by a qualified service person. Glass Door: Warning: Do not operate fireplace with glass door removed, cracked or broken. Replacement of the glass door should be done by a licensed or qualified service person. Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition. Do not strike or otherwise impact the glass in any way that may cause it to break. If the glass becomes cracked or broken it must be replaced before using the fireplace. Replacement door can be obtained from your nearest Pacific Energy dealer. Do not substitute with any other type. To remove broken glass, remove Door as noted in Door Removal section. Annual Inspection: a) Remove glass door and decorative media (such as logs and rocks). Inspect decorative media and burner assemblies for soot buildup. If excessive buildup of soot is present, have a qualified service person inspect and adjust unit for proper combustion. Clean burners with a brush or vacuum cleaner, paying close attention to burner ports. b) Check the pilot system for proper flame size and operation. Clean pilot free (Figure 89) of soot, dust or any other deposits. c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled for cleaning, it must be properly assembled and re-sealed. Ignitor d) Check and replace batteries as needed. Note: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids. Periodically: Hood a) Viewing glass may be cleaned as necessary with fireplace glass cleaner. b) Exterior finish may be cleaned with mild soap and water. Figure 89: Esprit pilot assembly. CAUTION: Do not use abrasive cleaners on glass or any other part of the fireplace. Do not clean glass when hot ESPRIT

49 Replacement Parts ESPRIT LINEAR GAS FIREPLACE SALES CODES UNIT SKU ESPRIT LINEAR GAS FIREPLACE REPLACEMENT PARTS ESPRIT REPLACEMENT DOOR WITH GLASS ESPRIT REPLACEMENT SCREEN COMPLETE REPLACEMENT GAS TRAY REPLACEMENT GAS VALVE REPLACEMENT CONTROL MODULE REPLACEMENT PILOT ASSEMBLY REPLACEMENT REMOTE CONTROL REPLACEMENT BLOWER BURNER OPTIONS LOG BURNER SET GLASS BURNER SET GLASS 5LB BLACK PANEL SETS PORCELAIN PANEL SET BLACK SURROUND AND TRIM OPTIONS CONTEMPORARY BACKING PLATE BLACK CONTEMPORARY BACKING PLATE GREY CONTEMPORARY FRONT TRIM PLATE GREY CONTEMPORARY FRONT TRIM PLATE - BLACK CONTEMPORARY FRONT TRIM PLATE - STAINLESS STRAIGHT EDGE FRONT TRIP PLATE - BLACK DESIGN OPTIONS TRANQUILITY ROCK SET METRO ROCK SET - BLACK METRO ROCK SET - GREY PERFORMANCE OPTIONS LP CONVERSION KIT ESPRIT

50 Wiring Diagram LED LED LAMP COMFORT FAN (4) AA Batteries PILOT BURNER Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing ESPRIT

51 Notes ESPRIT

52 2018 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer Pacific Energy Australia PTY LTD. Web site: Victoria Street, North Geelong, Victoria

SERIAL # TC36ST USER INSTRUCTIONS TC36ST SEE THRU OPERATING INSTRUCTIONS MODEL SERIES D MODULAR DIRECT VENT SEE-THRU FIREPLACE

SERIAL # TC36ST USER INSTRUCTIONS TC36ST SEE THRU OPERATING INSTRUCTIONS MODEL SERIES D MODULAR DIRECT VENT SEE-THRU FIREPLACE USER INSTRUCTIONS INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: If the information in these instructions is not followed exactly, a fire or

More information

INSTALLER: DOWNLOAD THE SERVICE MANUAL FROM

INSTALLER: DOWNLOAD THE SERVICE MANUAL FROM INSTALLER: DOWNLOAD THE SERVICE MANUAL FROM www.pefp.net INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: If the information in these instructions

More information

HOMEOWNER S MANUAL. CONTEMPORARY LINEAR VENT-FREE GAS FIREPLACE ModELS

HOMEOWNER S MANUAL. CONTEMPORARY LINEAR VENT-FREE GAS FIREPLACE ModELS HOMEOWNER S MANUAL Empire Comfort Systems has manufactured safe, reliable heating systems since 1932. We take pride in our reputation for quality products, backed by the best sales, service and distribution

More information

USER MANUAL TC30 USER MANUAL. MODEL TC30 SERIES D - Version 2 MODULAR DIRECT VENT FIREPLACE

USER MANUAL TC30 USER MANUAL. MODEL TC30 SERIES D - Version 2 MODULAR DIRECT VENT FIREPLACE INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. USER MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion

More information

Operation & Maintenance Manual

Operation & Maintenance Manual & Maintenance Manual Proflame 2 System NOTICE Read these instructions before use. WARNING Do not operate in presence of water dripping, spraying, rain, etc. ATTENTION - Turn OFF the main gas supply of

More information

TC42D - Version 2 USER MANUAL USER MANUAL SERIAL # MODEL TC42 SERIES D MODULAR DIRECT VENT FIREPLACE

TC42D - Version 2 USER MANUAL USER MANUAL SERIAL # MODEL TC42 SERIES D MODULAR DIRECT VENT FIREPLACE USER MANUAL INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: If the information in these instructions is not followed exactly, a fire or explosion

More information

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

SERIAL # INSTALLATION AND OPERATING INSTRUCTIONS. This appliance is suitable for installation in a bedroom or bed sitting room.

SERIAL # INSTALLATION AND OPERATING INSTRUCTIONS. This appliance is suitable for installation in a bedroom or bed sitting room. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury,

More information

SOUTHWEST FIREBIRD MFG SONORAN UNVENTED Model 36/42/48

SOUTHWEST FIREBIRD MFG SONORAN UNVENTED Model 36/42/48 SOUTHWEST FIREBIRD MFG SONORAN UNVENTED Model 36/42/48 INSTALLATION INSTRUCTIONS PREFABRICATED MODULAR MASONRY- UNVENTED SONORAN 36/42/48TO BE USED WITH UNVENTED GAS LOGS. SAVE THIS BOOK This book is valuable.

More information

27-DVIE22. Gas Fired Vented Room Heater (Direct Vent) USERS INSTALLATION OPERATION and MAINTENANCE MANUAL. S/N And up

27-DVIE22. Gas Fired Vented Room Heater (Direct Vent) USERS INSTALLATION OPERATION and MAINTENANCE MANUAL. S/N And up 27-DVIE22 Gas Fired Vented Room Heater (Direct Vent) S/N 270000 And up USERS INSTALLATION OPERATION and MAINTENANCE MANUAL WARNING: If the information in this manual is not followed exactly, a fire or

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

Models #CSK-31 #CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

Models #CSK-31 #CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Models #CSK-31 #CSK-31-RF CHASKA Direct

More information

DANGER HOMEOWNERS MANUAL. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

DANGER HOMEOWNERS MANUAL. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. HOMEOWNERS MANUAL INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. direct vent zero clearance gas fireplace heater series: DVCT40CFP95N-1 DVCT40CFP95P-1

More information

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W WALL MOUNTED ELECTRIC FIREPLACE HEATER Model # : 80001 Onyx 80002 Ivory 80008 - Mirror OWNER S MANUAL AC 110-120V 60Hz 1500W WARNING Read and understand this entire owner s manual, including all safety

More information

Models #CSK-335 #CSK-335-RF. CHASKA - XL Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

Models #CSK-335 #CSK-335-RF. CHASKA - XL Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Models #CSK-335 #CSK-335-RF CHASKA -

More information

616 GSR2 Insert (with screen) Owner s Manual

616 GSR2 Insert (with screen) Owner s Manual 616 GSR2 Insert (with screen) Owner s Manual WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use

More information

Using it in an enclosed space can kill you.

Using it in an enclosed space can kill you. 38 X 56 GAS FIRE PIT - OWNER S MANUAL Carlisle Chat Fire Table Base Model # 00GBC7 (6877B) Fits 6877A Carlisle Chat Fire Table Top For Propane and *Natural Gas (*See Page 7) Certified to CSA International

More information

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Installation Manual For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404M.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12

More information

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE 72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE Model Numbers: 80005 OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product.

More information

Installation/Operating Instructions

Installation/Operating Instructions Installation/Operating Instructions Models: 4072-180 24 NG 4072-182 30 NG Outdoor Hearth Kit DO NOT DISCARD INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this

More information

C44I OWNER S MANUAL DIRECT VENT FIREPLACE - IPI WARRANTY REGISTRATION enviro.com/warranty

C44I OWNER S MANUAL DIRECT VENT FIREPLACE - IPI WARRANTY REGISTRATION enviro.com/warranty WARRANTY REGISTRATION enviro.com/warranty C44I DIRECT VENT FIREPLACE - IPI OWNER S MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property

More information

Owner s Manual Direct Vent Gas Masonry Insert *Installation * Operation * Service * Parts * Model Number: DV1-M1

Owner s Manual Direct Vent Gas Masonry Insert *Installation * Operation * Service * Parts * Model Number: DV1-M1 TESTED BY: Owner s Manual Direct Vent Gas Masonry Insert *Installation * Operation * Service * Parts * Model Number: DV1-M1 Appliance Type: Direct Vent Gas Stove Heater for installation in solid fuel fireplace.

More information

Installation Manual EF5000 AUS & NZ

Installation Manual EF5000 AUS & NZ Installation Manual EF5000 AUS & NZ This manual is ONLY for fires with a serial No. from 80600 to 80999. Important: The appliance shall be installed in accordance with; Local gas fitting regulations Municipal

More information

Heat-N-Glo Fireplace. Installers Guide. Model: AT-GRAND

Heat-N-Glo Fireplace. Installers Guide. Model: AT-GRAND Heat-N-Glo Fireplace Model: AT-GRAND Installers Guide Patents Pending Underwriters Laboratories Listed WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY

More information

TOFINO INSTALLATION INSTRUCTIONS. MODEL: TOFINO i20s TOFINO i20m (SIT & Maxitrol versions) SERIES: A DIRECT VENT GAS INSERT

TOFINO INSTALLATION INSTRUCTIONS. MODEL: TOFINO i20s TOFINO i20m (SIT & Maxitrol versions) SERIES: A DIRECT VENT GAS INSERT INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: If the information in these instructions is not followed exactly a fire or explosion may result

More information

E44I OWNER S MANUAL GAS FIREPLACE INSERT - IPI WARRANTY REGISTRATION enviro.com/warranty. enviro.com/warranty. enviro.

E44I OWNER S MANUAL GAS FIREPLACE INSERT - IPI WARRANTY REGISTRATION enviro.com/warranty. enviro.com/warranty. enviro. WARRANTY WARRANTY REGISTRATION REGISTRATION enviro.com/warranty enviro.com/warranty E44I WARRANTY REGISTRATION enviro.com/warranty GAS FIREPLACE INSERT - IPI OWNER S MANUAL 4001609 Version Française: www.enviro.com/fr.html

More information

O-T L. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

O-T L. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. HUSSONG MANUFACTURING CO., INC. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly

More information

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D FOR YOUR SAFETY FOR YOUR SAFETY IF YOU SMELL GAS: DO NOT STORE OR USE GASOLINE 1. OPEN

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

WARNING HOMEOWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE HEATER MODEL SERIES:

WARNING HOMEOWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE HEATER MODEL SERIES: INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death

More information

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

USE AND CARE GUIDE WARNING WARNING WARNING WARNING USE AND CARE GUIDE Item No.: HF11501AA USE PROPANE GAS ONLY! -Do not store or use gasoline or other flammable vapors in the vicinity of this or any other appliance. - Service must be performed by a qualified

More information

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT Tool list Assembly Instructions Important Safety Instructions Listing Approvals Glass Particles Installation Instructions

More information

Legend VENTED GAS FIREPLACE HEATERS

Legend VENTED GAS FIREPLACE HEATERS MODEL 937XN FOR USE WITH NATURAL GAS Legend MODEL 937XP FOR USE WITH PROPANE VENTED GAS FIREPLACE HEATERS WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

More information

Installation Instructions

Installation Instructions Installation Instructions Models: ODGO324-MTCH, Grand Oak Match Light Gas Log Sets Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests

More information

E33I OWNER S MANUAL GAS INSERT - LOG SET WITH IPI VALVE WARRANTY REGISTRATION enviro.com/warranty

E33I OWNER S MANUAL GAS INSERT - LOG SET WITH IPI VALVE WARRANTY REGISTRATION enviro.com/warranty WARRANTY REGISTRATION enviro.com/warranty E33I GAS INSERT - LOG SET WITH IPI VALVE OWNER S MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing

More information

Installation Manual EF5000 NZ

Installation Manual EF5000 NZ Installation Manual EF5000 NZ Important: The appliance shall be installed in accordance with; Local gas fitting regulations Municipal building codes AS/NZS 5601.1.1:2010 Gas Installation Any other relevant

More information

616 Diamond-Fyre GSR2 Insert (with screen) Owner s Manual

616 Diamond-Fyre GSR2 Insert (with screen) Owner s Manual 616 Diamond-Fyre GSR2 Insert (with screen) Owner s Manual WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not

More information

STONE RIVER. The White Mountain Log Collection: LSU24SF-2 Shown

STONE RIVER. The White Mountain Log Collection: LSU24SF-2 Shown INSTALLATION Instructions AND Owner's Manual The White Mountain Log Collection: STONE RIVER Log Set for vented and UNVENTED MULTI-SIDED GAS LOG HEATER MODELS LSU18SF-2 LSU24SF-2 LSU30SF-2 LSU24SF-2 Shown

More information

E30I Gas Insert - Log Set & Proflame IPI Valve OWNER S MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARRANTY REGISTRATION

E30I Gas Insert - Log Set & Proflame IPI Valve OWNER S MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARRANTY REGISTRATION WARRANTY REGISTRATION IS QUICK AND EASY ONLINE: enviro.com E30I Gas Insert - Log Set & Proflame IPI Valve OWNER S MANUAL FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids

More information

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs,

More information

Corn Flame Energy Corn Stove Model 3000

Corn Flame Energy Corn Stove Model 3000 Corn Flame Energy Corn Stove Model 3000 Installation and Operation Guide Read thoroughly before starting installation Save this manual for future reference SAFETY NOTICE If this stove is not properly installed,

More information

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.), Hanover Outdoor Furniture IMPORTANT If you have any problems with this product (missing or damaged parts, assembly issues, etc.), PLEASE DO NOT RETURN TO THE RETAILER/STORE from where you purchased the

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. WARNING: If the information in this manual is not followed exactly, a fire

More information

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE! OWNER'S MANUAL READ BEFORE USE! Factory No.: HYFP30205-19 Style No.: 65209 For Outdoor Use Only! Use Propane Gas Only! - USE PROPANE GAS ONLY! Do not store or use gasoline or other flammable vapors and

More information

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL INSTALLATION INSTRUCTIONS AND OWNER S MANUAL DRIFTWOOD LOG SET FOR UNVENTED GAS LOG HEATER OR VENTED DECORATIVE APPLIANCE MODELS LS18CD-1 LS24CD-1 LS30CD-1 GAS-FIRED LS24CD Shown INSTALLER: Leave this

More information

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL RAVENWOOD LOG SET FOR UNVENTED GAS LOG HEATER OR VENTED DECORATIVE APPLIANCE STANDARD MODELS ALS18RV-1 ALS24RV-1 ALS30RV-1 GAS-FIRED SELECT MODELS ALS24RVS-1

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL 2005 Lennox Industries Inc. Dallas, Texas, USA USER S INFORMATION MANUAL 13GCSX SERIES UNITS GAS PACKAGED UNITS (2 5 TONS) Armstrong # 38152A068 505,058M 05/09 Supersedes 08/05 Table of Contents Litho

More information

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CSA Model 98300 DRF01000 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1.

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS CSA Model: 98910L Printed in China Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. WARNING: If the information in this manual

More information

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. FOUNDATION SERIES - BAY Co-linear Direct Vent Gas Fireplaces Installation and Operating Manual Natural Gas FDN-4-BAY FDN-5-BAY FDN-6-BAY FDN-7-BAY Installer: Leave this manual with the appliance. Consumer:

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

Pizza Oven with Stand

Pizza Oven with Stand Pizza Oven with Stand Cooks up to 3 pizzas at a time Use to cook a variety of food Easy clean vitreous enamel interior Model No. P0104 Powerful 22MJ/h stainless steel burner Viewing window and temperature

More information

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE OWNER S MANUAL WARRANTY REGISTRATION enviro.com/warranty

More information

EX35 I P I G A S F I R E P L A C E I N S E R T OWNER S MANUAL

EX35 I P I G A S F I R E P L A C E I N S E R T OWNER S MANUAL WARRANTY REGISTRATION enviro.com/warranty EX35 I P I G A S F I R E P L A C E I N S E R T OWNER S MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

More information

USE AND CARE GUIDE PEDESTAL FIREBOWL

USE AND CARE GUIDE PEDESTAL FIREBOWL DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department. WARNING

More information

NO VENTING REQUIRED 120V AC;

NO VENTING REQUIRED 120V AC; ELECTRIC FIREPLACE Model Number: Alice (EF172B-EF176B) OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product.

More information

Repeat procedures for other side.

Repeat procedures for other side. Repeat procedures for other side. ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model 98900 Printed in China DANGER

More information

Installation Requirements for Models:

Installation Requirements for Models: 900 & 9100 Series Refrigerators Installation Requirements for Models: 9162 9163 9182 9183 962 963 982 983 WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury

More information

SURE HEAT. Installation and Operating Instructions for NATURAL & L.P. GAS VENT FREE SYSTEM

SURE HEAT. Installation and Operating Instructions for NATURAL & L.P. GAS VENT FREE SYSTEM SURE HEAT Installation and Operating Instructions for NATURAL & L.P. GAS VENT FREE SYSTEM Model: SCVFMR18, SCVFMR 24/21, SCVFMR30 (LP or NG Versions) DANGER: FAILURE TO FOLLOW THESE INSTRUCTIONS CAREFULLY

More information

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS Model No. AH2069ODS, AH2063ODS The ideal solution for extending the season of outdoor entertaining Creates a stylish and attractive ambience Direct ignition Includes a safety tip-over switch that halts

More information

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE HEATER Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL 36"/45"/50"/60"/72"/100" LED Wall Mounted Or Built-in Electric Fireplace AC 110-120V 60Hz 1500W WARNING

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

PROBLEM CAUSE SOLUTION

PROBLEM CAUSE SOLUTION ------------------------------------------------------------------------------------------------------------------------------------------------- Troubleshooting Installer Only PROBLEM CAUSE SOLUTION Delayed

More information

Berkeley-IPI OWNER S MANUAL

Berkeley-IPI OWNER S MANUAL WARRANTY REGISTRATION enviro.com/warranty Berkeley-IPI FREESTANDING GAS FIREPLACE OWNER S MANUAL 4001609 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

More information

Outdoor Tabletop Heater TTH20 Series

Outdoor Tabletop Heater TTH20 Series Outdoor Tabletop Heater TTH20 Series FEATURES: The ideal solution for extending the outdoor entertaining season Creates a stylish and attractive ambience Casts an approximate 1 to 1.5 metre circle of radiant

More information

Owner s Manual Installation and Operation

Owner s Manual Installation and Operation Owner s Manual Installation and Operation Model: ST-42TVFL-IPI CAUTION DO NOT DISCARD THIS MANUAL Important operating Read, understand and follow Leave this manual with and maintenance these instructions

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

SURE HEAT MANUFACTURING

SURE HEAT MANUFACTURING SURE HEAT MANUFACTURING Installation and Operating Instructions for NATURAL & L.P. GAS A.G.A. SINGLE & DUAL BURNER VENTED UNITS Model: RP (8,24,30)-N GO (8,24,30)-N GLO (8,24,30)-N WO (8,24,30)-N CO (8,24,30)-N

More information

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL Serial Number Model Number CAT Number Quality checked by: Valued Customer, We are pleased that you have chosen to purchase

More information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG

More information

ELECTRIC FLAT PANEL FIREPLACE HEATER

ELECTRIC FLAT PANEL FIREPLACE HEATER ELECTRIC FLAT PANEL FIREPLACE HEATER Model Numbers: 80-2000A-42 OWNER S MANUAL AC 120V 60Hz 1500W WARNING Read and understand this entire owner s manual, including all safety information, before plugging

More information

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS CSA Model98900 DRS02403 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas:

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. MODELS: #PRC-36 / #PRC-36-RF PRINCETON

More information

INSTALLATION & OPERATING MANUAL

INSTALLATION & OPERATING MANUAL INSTALLATION & OPERATING MANUAL #942 DIRECT VENT DESIGN-CERTIFIED TO: DECORATIVE & WALL FURNACE ANSI PERFORMANCE & SAFETY STANDARDS U.S. PATENTS: #5.931.154, #5,967,139 #6,004,493 IMPORTANT: READ INSTRUCTIONS

More information

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W Flat Wall Mounted / Free stand Electric Fireplace Model Numbers: 80-421S OWNER S MANUAL Wall Hanging Mode Freestanding Mode AC 120V / 60HZ 1500W WARNING Read and understand this entire owner s manual,

More information

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. Sienna

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. Sienna SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. Sienna B Y : S H E R W O O D I N D U S T R I E S L T D OWNER S MANUAL PLEASE KEEP THESE INSTRUCTIONS

More information

The White Mountain Log Collection: ROCK CREEK

The White Mountain Log Collection: ROCK CREEK INSTALLATION Instructions AND Owner's Manual The White Mountain Log Collection: ROCK CREEK LOG SET FOR VENTED AND UNVENTED MULTI-SIDED GAS LOG HEATER MODELS LSU18RR-2 LSU24RR-2 LSU30RR-2 LSU18RR-2 SHOWN

More information

Heat-N-Glo. Installers Guide. Model: 8000TVC

Heat-N-Glo. Installers Guide. Model: 8000TVC Model: 8000TVC Heat-N-Glo Installers Guide Underwriters Laboratories Listed WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,

More information

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION ELECTRIC FLAT PANEL FIREPLACE Model# :80017 OWNER S MANUAL 50/60 - Built-in & Wall Mounted Electric Fireplace AC 110-120V 60Hz WARNING Read and understand this entire owner s manual, including all safety

More information

WSK300 Multifunction Wall Control

WSK300 Multifunction Wall Control WSK300 Multifunction Installation & Operating Instructions WARNING Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: Installation and

More information

The White Mountain Log Collection BIRCH

The White Mountain Log Collection BIRCH INSTALLATION Instructions AND Owner's Manual The White Mountain Log Collection BIRCH Log Set for UNVENTED GAS LOG HEATER OR VENTED DECORATIVE APPLIANCE MODELS LS-18B2-1 LS-24B2-1 LS-30B2-1 GAS-FIRED Installer:

More information

MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND.

MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND. MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND. WARNING: If the information in this manual is not followed exactly, a fire or explosion

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR PERFORMER SLIDE-IN COOK TOPS MODEL NUMBERS: AROBSCT-424, AROBSCT-242GD, AROBSCT-24X2GR, AROBSCT-430, AROBSCT-636, AROBSCT-436GD, AROBSCT-436GR,

More information

Patio Heater Model No. GM and GM

Patio Heater Model No. GM and GM Patio Heater Model No. GM124-003 and GM124-004 FEATURES: The ideal solution for extending the season for outdoor entertaining Maximum output 39.6 MJ/hr Direct ignition Adjustable heat output Safety tip-over

More information

PVK-80 Power Vent - Installation Instructions -

PVK-80 Power Vent - Installation Instructions - PVK-80 Power Vent - Installation Instructions - PVK-80 POWERVENT IMPORTANT: Failure to read and follow these instructions may create a possible hazard and will void the fi replace warranty. THESE INSTRUCTIONS

More information

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 506380 01 11/2009 KGA024, 030, 036, 048, 060, 072 (2, 2 1/2, 3, 4, 5, and 6 Tons) KGA092, 102, 120, 150 (7 1/2, 8-1/2, 10, and 12 Tons) KGA180, 210, 240,

More information

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB Star Manufacturing International Inc. 10 Sunnen Drive St. Louis, MO 63143 Phone: (314) 678-6303 Fax: (314) 781-2714 Installation and Operating Instructions 2M-Z20327 Rev. A 10/05/15 ULTRA-MAX GAS RADIANT

More information

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL WARNING

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL WARNING SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Sienna B Y : S H E R W O O D I N D U S T R I

More information

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents Installation Instructions T 9822 Gas Dryer To prevent accidents en - US, CA and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 2 WARNING For your safety the information

More information

Stone Hearth Pizza Dome Oven

Stone Hearth Pizza Dome Oven Stone Hearth Pizza Dome Oven INSTALLATION AND OPERATION MANUAL GAS-FIRED OVEN CAUTION This oven MUST be seasoned before initial use The seasoning procedure takes 6 days, running the oven for at least 8

More information

MODEL 329 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A FREESTANDING FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND.

MODEL 329 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A FREESTANDING FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND. MODEL 329 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A FREESTANDING FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND. VENT-FREE WARNING: If the information in this manual is not followed exactly,

More information

HD81 GLASS BURNER ASSEMBLY

HD81 GLASS BURNER ASSEMBLY INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. 1 INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA

More information

Table Top Patio Heater

Table Top Patio Heater Table Top Patio Heater INSTRUCTION MANUAL MODEL: HPS-B Certified by international recognized standards. The infra-red with heat wave outdoor heater. Variable control gas valve with electric push igniter.

More information

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. INSTALLATION AND OPERATING MANUAL Intrigue Series Direct Vent Gas Fireplaces Models: #INT-100 #INT-200 INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

More information

INSTALLATION & OPERATING MANUAL

INSTALLATION & OPERATING MANUAL INSTALLATION & OPERATING MANUAL MODELS: #932 DIRECT VENT WALL-FURNACE #936 DIRECT VENT WALL- FURNACE U.S. Patents: #5.931.154 #6.004.493 IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. FAILURE

More information

Wall Mount Electric Fireplace

Wall Mount Electric Fireplace Wall Mount Electric Fireplace User Guide Thank you for purchasing the Ivation Wall Mount Electric Fireplace. This User Guide is intended to provide you with guidelines to ensure that operation of this

More information