Conventional methods NEW GENERATION SOLAR HYBRID HOT WATER SOLUTIONS

Size: px
Start display at page:

Download "Conventional methods NEW GENERATION SOLAR HYBRID HOT WATER SOLUTIONS"

Transcription

1 NEW GENERATION SOLAR HYBRID HOT WATER SOLUTIONS Ranjith M MEP Consultant based in Kochi. He is also NEC Member, IPA Kochi Chapter. Integrated Building Consultants 54/2477A,Subash Chandrabose Road,Kadavanthara P.O, Kochi P: , M; E: ibcconsultants@rediffmail.com Conventional methods for generating hot water usually require direct or indirect burning of fossil fuels, example oil or gas, for the generation of electricity to heat water. These methods not only have high operating costs for the consumer but also result in the emission of harmful pollutants in the environment. The use of free solar energy to generate hot water via solar collectors can offset these energy requirements, with conventional solar systems being able to provide typical energy savings or a Solar Contribution Factor SCF of 50% to 80% of daily water heating requirements. The remaining energy requirement, especially on days with poor solar contribution due to cloudy weather etc., is normally provided from traditional fuel burning methods or electric resistive heating elements. A Heat Pump is an efficient device that moves heat from one location called the 'source' at a lower temperature to another location called the 'sink' at a higher temperature. This process is commonly seen with reverse-cycle airconditioners. Heat pump technology can be used as a very efficient method of generating hot water. Energy in the form of ambient heat is first extracted from the surrounding air and is used to convert the refrigerant within the sealed system into a gas. The gas is then compressed to generate even more heat, which is used to heat the water in the tank. Temperatures of up to 60 C are readily achievable. In ambient temperatures of 20 C and above, heat pumps typically have a Coefficient of Performance (COP) of or higher; which means that for every 1 kw of input electrical energy, kw of heating to the water is obtained. This means kw is gained free which is from the ambient air. The COP of conventional electric water heaters is 1, which means that only 1 kw of heating is obtained from every 1 kw of input electrical energy. Summary: By combining Heat Pump technology in conjunction with solar collectors (a hybrid solution) some powerful synergies can be gained. Example: Let s consider an example, a typical scenario of a customer with a daily water heating requirement of 10,000 litres. To heat this volume of water from 20 o C to 60 o C requires approximately 480 kwh of energy per day. If we heat this volume of water with conventional electric resistive heating (COP of 1), we would require on average 480 kw of electrical energy input per day. 14

2 If we were to utilize solar energy instead, with enough solar collectors installed to provide an average of 75% solar contribution factor, with the remaining energy requirement being supplied from electric resistive heating, we would require on average approx. 120 kwh of electrical energy input per day. Alternatively, if we were to halve the quantity of solar collectors installed, such that a solar contribution of 37.5% was now expected, and utilize a heat pump for the remaining energy requirement of 62.5%, as the heat pump has a typical COP of 4, the required electrical input would be 62.5% / 4 = 15.6%, which equates in our example to only 75 kwh of electrical energy per day. The heat pump is providing approximately 46.9% (225 kwh) of the heating requirement for free (62.5% %), when combined with the 37.5% of free energy from the sun, means that 84.4% (405 kwh) of our average daily water heating energy is provided at no cost! Hence the energy savings for the hybrid solution are much greater than for either a conventional solar solution or a solution based on the installation of heat pumps alone. There is a lot of talk of going green, saving energy, green buildings, solar energy, heat pumps and solar hybrid systems. It has to be noted that one has to be careful and also clear in choosing a technology for a particular requirement on hand. This article will guide one to choose the right technology and system that will perform effectively and also has a low life cycle cost. The hot water system should be adequately protected from both internal and external factors that affect the durability, reliability and performance directly and most importantly the safety. One of the critical factors to consider before a purchase of a system is whether to go with direct heating technology or indirect heating technology. In case of direct heating, one allows water to flow through the collectors or any other heat exchanger such as the PHE or the coaxial heat exchanger inside the heat pump to exchange heat. This can be done provided we have very good water quality. What we mean by this is to use water with very low impurities. The impurities in water are of two types - suspended and dissolved. The impurity that affects system performance is the dissolved impurities as in water with high TDS and hardness. This is the quality of water that is generally available for use. Water quality is generally not good in many parts of the country. The hardness in water causes scaling even on a very smooth surface such as glass and at ambient temperatures. March 2018 / 15

3 Scaling is highest at higher temperatures. One can imagine the kind of scaling that can happen inside the collectors and also in the heat exchanger inside the heat pump if such water is allowed to flow or used. Scaling causes reduction in efficiency, performance, increase in running cost and failure of the collectors and heat exchanger inside the heat pump. There is also high maintenance cost and down time involved in descaling the system. The descaling is done with acid that corrodes the material and in some time the heat exchanger as well as the collector fails. Indirect type of heating does not allow the water to pass through the solar collectors or through the heat exchanger inside the heat pump. Usually a close circuit liquid that is anticorrosive and anti-freeze in nature is used to transfer the heat thus eliminating the complications as explained above resulting in effective performance of the system with high efficiency, durability and reliability with a very long life, no or low maintenance and very low life cycle cost. Summary: An indirect type of heating system is better, more suitable for the conditions prevailing; performance is better, lower maintenance costs and has a long life and hence has a very low life cycle cost. Once the decision is taken about whether the system has to be direct or indirect then the components that go into the system like storage tanks, collectors, heat pumps, insulation, etc. have to be chosen Storage Tank: One of the most common problems with conventional hot water system is the storage tank. It is quite common that most of the local and ordinary hot water systems use stainless steel to fabricate the hot water tank. It is also the most common part to fail or needs constant repair and maintenance due to leakage due to corrosion. Corrosion is a chemical change that occurs on the surface of the metal and rusting is the most common example. Few metals escape corrosion in water regardless of their quality including stainless steel. Gold or platinum do not corrode but their cost and properties make them unsuitable for storage water heaters. The damage to a stainless steel tank is even greater and more rapid should it be pressurized. Storage tanks manufactured Corrosion begins its and tested under DIN 4753 Standards. destructive process as a result of small flaws on metal surfaces, at weld points or from stress. A common assumption is that water is not corrosive. This is not the case and some water supplies are more corrosive than others. Hot water storage systems are not immune from corrosion and the most effective way of dealing with the problem is to fuse the inside of a strong steel storage tank with a ceramic lining to isolate the tank structure from potential corrosion. Thus ceramic lined or enamelled tanks are best suited for hot water storage. What is enamel coating process? The enamel coating on a metal is basically a glass like material. Enamel is fused with steel due to an electro chemical reaction. The coating acts as an electric insulator; it completely avoids galvanic corrosion and also results in unity, smooth and anti-adhesive surface. The enamel coating provides maximum protection for the base metal. The coating does not transmit any odour to water and it does not affect any flavour. Enamel does not give out any toxic or allergic substances. The enamel coating is available in two colours blue and white, but both having same properties. The physical strength of enamel is determined by the compression strength that it can handle. Similarly the enamel is chemically acid resistant, alkali resistant, resistant to attack from detergents, hot water, steam and steam condensate. Unique features: The enamel has a symptomatic behaviour which means that the corrosion decreases as the enamel coating become older. It is absolutely hygienic since its closed surface does not allow bacteria to accumulate Enamel coating does not allow any solid, liquid and gas to react or come into contact with the steel base 16

4 Glass lined steel is mandatory wherever the service conditions of the process is particularly difficult Why is enamel coating so reliable? The enamel composition is inorganic in nature; there is a chemical bond between the enamel layer and the metal surface after the fusion of the glassy substance at over 800 C in the oven during the baking process. The steel contributes to the mechanical strength, while glass enamel guarantees the chemical resistance with rust protection because it does not absorb water or conduct ions. The enamel provides the steel tank with 99.9% rustproof protection, as there may be the occasional uncoated points though this happens very rarely. The remaining 0.1% is guaranteed by inserting magnesium sacrificial anodes. Once these have been installed inside the steel tank, they control the action of the agents that may otherwise eventually cause rusting. Protection against corrosion: It is wise and advisable to take corrosion protection even further by the installation of a simple replaceable component that takes the brunt of any corrosive potential the water may have. By using a bare metal component (known as an anode ) which is a more readily corrodible metal, it protects the tank. This approach to corrosion protection is employed all over the world where metal objects are immersed in water. Literally billions of dollars are invested in ships and oil rigs worldwide - they are all protected by replaceable anodes which withstand the harshest of climates and water conditions. Over time, the anode dissolves, releasing a completely harmless magnesium salt into the water. The life of the anode varies depending on the quality of the water typically between 5 and 15 years. Bare steel is never exposed to water in the system. An added advantage with a protective anode is that it can be easily checked during regular services and replaced, as necessary, to ensure lasting protection of your tank and extend the life of your water heating system. Summary of Advantages of Enamelled Tanks with Anode protection: Protective coating: 3/10 mm (0.3mm) ceramic lining fused to steel at 850 C. Extent of pin-holes and crevices in protective coating: Pin-holes limited to 0.01% of surface area of coating. Design avoids crevices. Galvanic corrosion mechanism: Magnesium anode corrodes in preference to steel to protect the steel at pin-holes present in the enamel coating. Pit and crevice corrosion mechanism: Magnesium anode releases ions that attract chloride (Cl) ions, dissolved magnesium chloride (MgCl 2 ) gets flushed away. Stress corrosion mechanism and fatigue corrosion mechanism: Thick steel tank walls (2.0 to 2.5mm) are lightly stressed and less susceptible to fatigue. Mechanical fatigue: All pressurized water heater storage tanks are subject to pressure cycles that lead to metal fatigue of the tank walls. If corrosion failure does not occur first, fatigue failure will eventuate. Thick wall sections are less susceptible to fatigue failure than thin sections. Flange for mounting element: The storage tank should have a suitable flange for mounting the auxiliary heating element of the required capacity around the centre of the tank. The auxiliary boost should heat only top half of the tank. Flange mounting at bottom or top: A larger flange needs to be provided at the bottom of the tank thereby periodic cleaning and maintenance work can be carried out. The anode tends to corrode and settle as fine powder at the bottom of the tank which should be periodically cleaned. Temperature and pressure relief valves: Close circuit indirect systems are preferred to open vented direct systems as explained earlier. The close circuit and the storage tank are well protected with the installation of temperature and pressure (T&P) relief valves. In case of overheating or excess pressure, the valve opens automatically and releases the excess pressure or dumps water and reduces the excess temperature. These valves have to be of the specifications required for both temperature and pressure and have to be calibrated. Valves of reputed makes only should be used. Temperature gauge: It is recommended to fix a silicon filled thermometer to give a steady reading of the stored water. Temperature Sensors: Only sensors and probes of high quality and reliability should be used in the designated place on the tank and the heat pump for proper feedback to the controllers and also to maintain right temperature in the system. Collectors: There are several types of collectors available in the market at various price levels. Each has its own advantages as well as disadvantages. Evacuated tube collectors are higher in efficiency in the beginning but in the long run when the tube loses the vacuum due to sealing issues between two materials having different 18

5 coefficient of expansion, the efficiency drops. ETCs are prone to breakages, handling and maintenance issues. The most common fin and tube collectors are almost obsolete and outdated in the developed world due to poor construction and very low efficiency. Constant research and testing at various site conditions has proved that flat plate collectors with electronically sputtered surface finish with a suitable selective surface coating are the best in terms of efficiency, constant performance, durability, reliability and most importantly, value for money. The best coating available today is titanium oxide and it goes with various brand names like Bluetech, blue coated selective surface coating. Collectors should be tested andcertified as per EN under BIS &TÜV SÜD America Standards type with the heat pump taking a major load. There are two main types of heat pumps available air to water and water to water heat pumps. The air to water heat pump uses the ambient air as the heat source as it absorbs the heat from the ambient air. The by-product of air to water heat pump is cold air. The air expelled out is about 6-7 C lower than the ambient air. In a water to water heat pump water is the source. Heat exchange takes place with the water medium. The by-product of water to water heat pump is cold water which is lower by 5-6 C than the inlet water temperature. There are many manufacturers in the world who offer heat pumps. The critical components in a heat pump are the compressor, evaporator coil, heat exchanger, expansion valve and heat pump controller. The company that offers the best combination of all of these, has reliable electronics with PLC, offers test certificates and only declares the COP after testing in an isothermal laboratory under varying conditions will be the heat pump to opt for. The compressor is the heart of the equipment and has to be of a reputed make and type. The most efficient compressors that are available today are scroll type from major manufacturers like Copeland, Panasonic, Mitsubishi, etc. The refrigerant used should have distinct product behaviour and thermodynamic characteristics and be the one suitable for a compressor to work on a heat pump. There are several refrigerants available but the better and more suitable refrigerants are 407 C, 410 A and 134 A. They are green and environmentally friendly and are also available in plenty in India. Summary: A flat plate collector with electronically sputtered surface finish with titanium oxide (Bluetech) coating is the best suited for our conditions. Heat Pump: The heat pump is an integral part of the hot water system especially if the system installed is of hybrid The evaporator coil plays a very important role in the system. The COP of the system depends on the efficiency of this coil. The coil being metal is exposed to vagaries of the environment especially if installed in corrosive climatic conditions and also near the sea coast. The coil should have a good protective coating against corrosion. The good coatings available today are the Kirby Coating which is blue in colour and Gold coating that is gold in colour. March 2018 / 19

6 Heat Exchanger Heat exchanger is the vital component and as the name suggests it is where the main heat exchange function happens. There are many types of heat exchangers that are available. The differences are based on type of construction like plate type, shell in tube and coaxial type and on materials like copper/pvc, PVC/titanium, titanium/titanium etc. One has to carefully choose the type of heat exchanger based on the type of heat pump and the application. The gap in the walls of the heat exchanger is narrow and limited by design. The heat exchange surface reaches high temperatures. If the quality of water flowing across the heat exchanger is not good, with hardness and TDS, then this will cause scaling on the walls of the heat exchanger gradually reducing the efficiency and finally choking the tube causing failure of the heat pump. Expansion valve throttles the refrigerant from high pressure to lower pressure to be ready for the next cycle. Thus precise functioning of the valve is required to fully utilize the characteristics of the chosen refrigerant. Heat pump controller is the brain and controls the entire functioning of the heat pump. It also acts to protect the heat pump from over load, low flow, overheating; apart from making the heat pump work under the set parameters. The controller has to be most reliable, easy to operate and least complicated as this governs the working of the heat pump. It is very important to choose the right heat pump in terms of technology, capacity, refrigerant used, coating on the coil, body material and type of heat exchanger based on application. But above all, it is very important to run the heat pump on close circuit fluid as indirect heating system than circulate water directly. Most heat pumps fail due to scaling caused by poor quality of the water that is supplied. Insulation: It is most common to see stainless steel water tanks being covered by mineral/rock wool as insulation and an aluminium cladding wrapped around it. It is important to note that this is a very old and primitive form of insulation where the thermal loss is quite high. Apart from this, both mineral and rock wool are hazardous material, carcinogenic, not child safe and is banned in the developed world. It is important to have a good insulation and polyurethane (PU) is the most suitable material available. Both soft and hard forms of polyurethane foam can be used in full when injected around a jacket or in sections to wrap around the hot water storage tank. Manufacturing as per Chapter-6 USEC-India under IPA-2017 Standards. Summary: Polyurethane insulation around the tank is best suited for our climatic conditions and also for long life and better performance of the system. Installation & Commissioning: The best designed equipment, comprising high quality components, will perform well and as per the design requirement only if it is installed and commissioned in the right or proper way. The entire equipment must be housed in a suitable place. The tanks should not be directly exposed to the weather and all the electrical and electronic controls must be protected from water and rain. The heat pumps should have proper ventilation. Plumbing: Once the equipment sizing is done to suit the requirement, the plumbing should also be designed 20

7 to connect all the subsystems that comprise the equipment for optimum performance of the system. The plumbing design and execution must be done by plumbing and hot water experts and only those who are well trained in installation work and safety. The plumbing material recommended is a metal pipe either of copper or SS for the solar circuit as the temperature can be high. The high temperature will determine the choice of material for the other plumbing lines for the heat pump, supply or return line. All the lines must be completely, properly and neatly insulated to avoid any loss of heat or energy. The insulation should be UV stabilized for exposed areas and properly covered if required. ( Chapter 8 USEC-India under IPA-2017 Standards) Commissioning: Once the plumbing is installed, the commissioning should be in sequence and as per individual subsystem requirement. The close circuit fluid must be filled in the right quantity and dilution rate along with DM or distilled water, or treated water if available at site, pressurized and tested. The circulation can be switched on only if there is no pressure drop or any leakage detected in the system. Thereafter the controllers and PLC are programmed as per the design and hot water requirement. The hot water circulation must be switched on after a couple of hours and the cut in and cut off time must be correctly set on the timer/temperature based control panel. The system must be allowed time to stabilize before there is a draw off. Running and Maintenance: After the system is correctly installed and commissioned it should be completely on auto mode. There is no requirement for constant interference to manage the system. However it is mandatory to check the working parameters on a daily basis to ensure smooth running of the system. Please ensure the collectors are clean, pipe lines are clear, the circulating pumps are working smooth, the hot water circulation pump is working on timer as per the setting, the drain pipes from heat pumps are not clogged and ensure that there is no leakage in the close circuit or the supply and return lines. Annual Maintenance contract: On the completion of the defects and liabilities period it is advisable to award AMC to a competent agency preferably to the company that has installed and commissioned the system. Conclusion As we conclude this article we have to emphasize the importance of equipment design: it is very important to design the equipment to best suit the site requirements. The requirement has two sides: one is the actual hot water demand and the other is to suit the equipment as per the site conditions. Sizing: A detailed study is required to estimate the hot water demand. The daily demand depends on the number of persons using hot water, other areas of hot water consumption such as spa, kitchen, restaurants, back of the house and laundry. The type of shower fittings and equipment in use such as regular shower, shower panel, rain shower, bath tub and jacuzzi determines the quantity of hot water required per person as each fixture has different flow rates. Site Conditions: Each site is different in terms of location and available area for the equipment. It is best to check the available space on the terrace and in the plant room before we select the equipment including number of collectors, storage tanks, heat pumps, expansion tanks and controllers. It is very important to ensure proper ventilation for the heat pump so that it can draw fresh ambient air and be able to transfer cold air away from the equipment. ipt March 2018 / 21

Solar water heating system

Solar water heating system Solar water heating system Perhaps the most popular application of solar systems is for domestic water heating. The popularity of these systems is based on the fact that relatively simple systems are involved

More information

Five reasons to buy a solar water heater:

Five reasons to buy a solar water heater: Five reasons to buy a solar water heater: 1. Reliability Constant hot water Optional electrical or gas boosting available Storage capacity is nearly double than that of most other conventional systems

More information

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 1 2 3 Once again, the Energy Panel team has put all their excitement and enthusiasm to create this new publication. We want to make

More information

Soak in the Sunshine. Solar Hot Water

Soak in the Sunshine. Solar Hot Water Soak in the Sunshine Solar Hot Water Soak in the sunshine, and SAVE with solar hot water from Chromagen USES UP TO 80% LESS ENERGY With a solar hot water system from Chromagen, you can literally soak in

More information

So far, we have covered the basic concepts of heat transfer and properties.

So far, we have covered the basic concepts of heat transfer and properties. ET3034TUx - 6.2.2 - Solar thermal energy 2 - Solar thermal heating So far, we have covered the basic concepts of heat transfer and properties. Now we are going to discuss the applications of these concepts

More information

INDIRECT SYSTEM FOR FROST LOCATIONS

INDIRECT SYSTEM FOR FROST LOCATIONS SOLAR WATER HEATING INDIRECT SYSTEM FOR FROST LOCATIONS EFFICIENT USE OF NATURAL SOLAR ENERGY FROM THE DOMESTIC SOLAR WATER HEATERS WITH SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Water Heaters

More information

EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1

EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1 EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1 Thermann Solar Hot Water System - Owners Manual Thank You Thank you for purchasing a Thermann solar hot water system. Please

More information

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 2 3 Heat Merchants have partnered with Energy Panel to offer the most advance technology in Thermodynamic Solar Systems for both residential

More information

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the operation of reverse-cycle refrigeration (heat pumps) Explain

More information

and sanitary hot water Catalogue 2009

and sanitary hot water Catalogue 2009 heating, COOLING and sanitary hot water Catalogue 2009 LG Electronics Magyar Kft. H-1097 Budapest, Könyves K. krt. 3/a. (+36-1) 455-6060 www.lg.hu www.lgeaircon.com http://lgacademy.csx.hu For continual

More information

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING How to deal with R32 R125 R410A...R410A MITSUBISHI ELECTRIC AIRCONDITIO NING R410A Contents What is R410A?......................................... 3 Expressions...........................................

More information

Precision Storage Vessels ELECTRIC WATER HEATERS

Precision Storage Vessels ELECTRIC WATER HEATERS Precision Storage Vessels ELECTRIC WATER HEATERS High Capacity Electric Water Heaters Electric calorifiers are one of the easiest method of generating hot water for both domestic and industrial application.

More information

Heat Pump Water Heater

Heat Pump Water Heater MODEL PBX Heat Pump Water Heater Fully Integrated Heat Pump Water Heater (HPWH) 40-119 Gallon Capacity Features Highest Efficiency Heat Pump transfers heat from surrounding air into the hot water tank

More information

Q1. The diagram shows an experiment to find out what happens to infrared waves when they strike different surfaces.

Q1. The diagram shows an experiment to find out what happens to infrared waves when they strike different surfaces. Q1. The diagram shows an experiment to find out what happens to infrared waves when they strike different surfaces. (a) The water in the black tube gets hotter than the water in the shiny tube. Choose

More information

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 ENVIRONMENTAL ASPECTS.. 6 SPECIAL REQUIREMENTS.. 8 MANUFACTURER CONSIDERATIONS.. 8 SELECTING AN ENCLOSURE AIR CONDITIONER.... 9 2 Although the selection

More information

Refrigeration Plant Information. We Speak Hockey 365

Refrigeration Plant Information. We Speak Hockey 365 Refrigeration Plant Information We Speak Hockey 365 Introduction For 100 years, it s been accepted that ice rinks come with a multitude of expensive and reoccurring problems; not to mention astoundingly

More information

Section 2: Solar Water Heating Systems focuses primarily on the common solar system design types.

Section 2: Solar Water Heating Systems focuses primarily on the common solar system design types. Section 2: Solar Water Heating Systems focuses primarily on the common solar system design types. Module: System Types describes and illustrates the main types of solar water heating systems, along with

More information

Solar Hot Water. PV + Heat Pump or Thermal. Which is better?

Solar Hot Water. PV + Heat Pump or Thermal. Which is better? Solar Hot Water Which is better? PV + Heat Pump or Thermal http://www.halslater.com/solar-hot-water.htm Solar thermal is temperamental, really. Water weight limits design Expands when it freezes Steam

More information

Installation and Commissioning Manual

Installation and Commissioning Manual Manual Advance Buffer Vessels for Ground Source Heat Pump Systems Installation and Commissioning Manual Copyright 2015 Kensa Heat Pumps Ltd Page 1 of 12 Contents Page Section Description Page 1... Safety

More information

Understanding Solar Types

Understanding Solar Types Understanding Solar Types Understanding Solar Water Heating Technologies, Advantages, Disadvantages, Types and Our Opinions 1 Initial Steps to Understand There are 2 main components; the solar collector

More information

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS SOLAR THERMAL SOLUTIONS The great advantage of having a Solar Water heater is ITS FREE! The benefits

More information

Stainless Steel Unvented Cylinders

Stainless Steel Unvented Cylinders Stainless Steel Unvented Cylinders 1992 Tornado 1 1996 Tornado Elite 1999 Tornado 2 2002 Tornado and Tempest Stainless Steel Modern Day Requirements More people are finding that today s requirements for

More information

25 per cent of energy used in the home is used to heat water.

25 per cent of energy used in the home is used to heat water. Water heating accounts for 25 per cent of the energy used in an average home and is responsible for 23 per cent of the total greenhouse gas emissions from home energy use. Reducing your hot water use and

More information

CONTENTS. 1 cooling technology white paper

CONTENTS. 1 cooling technology white paper Using Surface Coatings to Extend LIfe and ImprovE Performance in industrial air conditioners CONTENTS 1. Introduction 2. Type of Corrosions 2.1 Galvanic Corrosion 2.2 General Corrosion 2.3 Formicary Corrosion

More information

Apricus Solar Hot Water Systems

Apricus Solar Hot Water Systems Apricus Solar Hot Water Systems Owners Manual Version 2.0 - March 2012 AA-8.2.1.7.2.Apricus-Owners-Manual-V2.0 www.apricus.com.au Thank You! Thank you for purchasing an Apricus solar hot water system.

More information

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler H o t Wa te r Syste m s Senator Electric Flow Boilers Making Life Simpler Electric Wet Central Heating The Range Senator electric flow boiler is designed to heat re-circulated water used in wet central

More information

Commercial Heat Pump Water Heating Solutions

Commercial Heat Pump Water Heating Solutions Commercial Heat Pump Water Heating Solutions - Swimming pool and spa heating - Pool enclosure ventilation + heat recovery - Commercial hot water - Underfloor heating www.waterheating.co.nz reliable If

More information

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Air Conditioning Clinic Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN Absorption Water Chillers One of the Equipment Series A publication of The Trane Company Worldwide Applied Systems

More information

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018 AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018 Q 1: What is AQUABION? A: AQUABION is a treatment for limescale in water systems consisting of a

More information

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DIRECT DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Heaters - Close Coupled & Split - Direct System direct

More information

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element =Classic range= Classic range technologies Magnesium anode The magnesium anode is located in the centre of the enamelled tank and provides excellent protection against corrosion; this anode is consumed

More information

SECTION Boiler Controls & Waste Heat Recovery

SECTION Boiler Controls & Waste Heat Recovery 6 Boiler Controls & Waste Heat Recovery ARMSTRONG PRODUCT CATALOGUE 255 IGEMA BOILER LEVEL & TDS CONTROLS IGEMA offers boiler level and TDS control products of the highest quality standard, being certified

More information

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump HEAT PUMP WATER HEATER EXPLORER 7% energy savings * Wide temperature range of use (- to + C) ACI hybrid anti-corrosion protection Smart energy consumption control Remote piloting with Cozytouch technology

More information

I Solar Water Heating System

I Solar Water Heating System I Solar Water Heating System READY FOR YOUR FAMILY S EVERYDAY HOT WATER NEEDS bringing solar energy to every home Cost efficient hot water for basic domestic use is a key requirement of every home owner.

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Milk cooling systems

Milk cooling systems Milk Cooling Systems Milk cooling systems Milk Cooling Systems DARI-KOOL DX-FF 1. High Durability Every DX-FF tank is manufactured from high quality stainless steel resulting in a superior hygienic finish.

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Aqua 1 plus Air-water heat pumps for domestic hot water production

Aqua 1 plus Air-water heat pumps for domestic hot water production Aqua 1 plus Air-water heat pumps for domestic hot water production THE FLEXIBLE EFFICIENCY is a range of heap pumps for domestic hot water production, fit for small residential applications. It is the

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY PRIME COMMERCIAL CONDENSING GAS WATER HEATER 40-119 GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY WATER HEATERS TM (Optional) TM THE ULTIMATE IN CONDENSING GAS WATER HEATING THE PRIME ADVANTAGE Industry's

More information

Scroll Water Cooled Chiller

Scroll Water Cooled Chiller Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the elements is

More information

Refrigeration Technology in Building Services Engineering

Refrigeration Technology in Building Services Engineering Unit 70: Unit code: T/600/0459 QCF Level: 3 Credit value: 10 Guided learning hours: 60 Unit aim Refrigeration Technology in Building Services Engineering This unit develops an understanding of the principles,

More information

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) 4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been

More information

STORAGE WATER HEATERS

STORAGE WATER HEATERS Owners Manual STORAG WATR HATRS RBC 200, RBC 300, RBC 400, RBC 500, RBC 500HP, RBC 750, RBC 1000, RBC 1000HP, RBC 1500, RBC 2000, RBC 3000 N v. 1.4 CONTNTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection...

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the is immediately

More information

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS WATER HEATERS, STORAGE TANKS 6 Flamco and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS 2007 edition / UK Flamco glass lined water heaters for potable and heating installations Flamco

More information

NUOS RANGE HEAT PUMP WATER HEATERS

NUOS RANGE HEAT PUMP WATER HEATERS RANGE HEAT PUMP WATER HEATERS 1 HOW TO READ THE SYMBOLS The icons have been designed to facilitate the reading of the features of each product. Ariston makes it possible, from the very beginning, to quickly

More information

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE A. O. Smith www.hotwater.com A. O. Smith Tankless Advantage ENDLESS HOT WATER * Heating water only as it s being used means you will never run out of

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier

Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier Introduction: Deionized water, referred to as DI Water, has emerged as an indispensable component in process applications. From

More information

Adelaide Homes Design Guide 4 - Winter warming

Adelaide Homes Design Guide 4 - Winter warming Adelaide Homes Design Guide 4 - Winter warming Adelaide's temperate climate means home warming is required during winter. There are many efficient heating systems. The most economical method, however,

More information

Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers

Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers Q: Can you explain how a swamp cooler works and/or is different? A swamp

More information

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector International Conference on Mechanical, Industrial and Materials Engineering 2015 (ICMIME2015) 11-13 December, 2015, RUET, Rajshahi, Bangladesh Paper ID: ET-46 Experimental Investigation of a Hybrid Evacuated

More information

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools Laird Engineered Thermal Systems Application Note Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools March 2017 Table of Contents Introduction...3 Cooling Systems...3 Technical Requirements...4

More information

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C McQuay International (A Member of the DAIKIN Group) Hydrofluorocarbon (HFC) refrigerants are critical to the safe and cost-effective phase-out

More information

Reinventing Energy Efficiency

Reinventing Energy Efficiency Commercial WATER2AIR EC LARGE SERIES Reinventing Energy Efficiency www.fhp-mfg.com Environmental stewardship is a core philosophy for FHP Manufacturing from design to production to the reduction in our

More information

Sweden s leading air source heat pump

Sweden s leading air source heat pump - Since 1939 ExoAir / ExoAir Polaris GreenEnergy Sweden s leading air source heat pump BEST IN TEST The Swedish Energy Council recently scored the Euronom air source heat pump as the leading product of

More information

Changes of phase usually involve a transfer of energy Evaporation

Changes of phase usually involve a transfer of energy Evaporation Changes of phase usually involve a transfer of energy. The four possible forms of matter solid, liquid, gas, and plasma are called phases. Matter can change from one phase to another. The phase of matter

More information

Kills bills. How Vaillant technologies reduce home heating bills

Kills bills. How Vaillant technologies reduce home heating bills Kills bills How Vaillant technologies reduce home heating bills Energy efficiency is a choice For most people, home heating and hot water systems have always been out of sight and out of mind. But now,

More information

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points Name: Start time: End time: FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points 1. What are the units of the following quantities? (10 points) a. Enthalpy of a refrigerant b. Dryness fraction of

More information

DOMESTIC STEAM GENERATOR Installation Instructions

DOMESTIC STEAM GENERATOR Installation Instructions DOMESTIC STEAM GENERATOR Installation Instructions Please read all of the instructions carefully before commencing installation or using the facility. Contents INTRODUCTION Page 2 TECHNICAL SPECIFICATION

More information

OVERVIEW OF THE ELECTRIC RADIATORS RANGE

OVERVIEW OF THE ELECTRIC RADIATORS RANGE ELECTRIC HEATING OVERVIEW OF THE ELECTRIC RADIATORS RANGE Our contemporary slimline design range of electric radiators spans from 500 watts to 2000 watts in output, covering the most popular requirements

More information

9. Cooling Water System

9. Cooling Water System 9.1 Water quality The fresh water in the cooling water system of the engine must fulfil the following requirements: ph... Hardness... Chlorides... Sulphates... min. 6.5...8.5 max. 10 dh max. 80 mg/l max.

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS 17 West Street West Hatfield, MA 01088 Phone: (413) 247-3380 * (800) 582-8423 Fax: (413) 247-3369 E-mail: info@stiebel-eltron-usa.com SB 150, SB 200 Glass Lined Indirectly Fired Water Heaters With Single

More information

It pays to go green with solakool

It pays to go green with solakool It pays to go green with solakool Brought to you by: Introducing Clean System Energy International CSEI (Clean System Energy International) is a Brisbane company based in Brendale and our focus is to help

More information

Vapour Jet Refrigerator / Heat Pump R853

Vapour Jet Refrigerator / Heat Pump R853 Vapour Jet Refrigerator / Heat Pump R853 Enables demonstration and investigation of the combined Rankine and Vapour Compression Cycle Is an example of a refrigerator or heat pump driven by a Heat Input

More information

UNVENTED WATER HEATERS. Water Heater Display Stand

UNVENTED WATER HEATERS. Water Heater Display Stand Water Heater Display Stand 26 28 5 L & 10 L UNVENTED WATER HEATERS 30 PLUMBING INSTRUCTIONS EXPANSION VESSELS 32 15 L & 30 L UNVENTED WATER HEATERS 34 50 L & 100 L UNVENTED WATER HEATERS 27 5 Litre and

More information

Single-Felt Dryer Sections

Single-Felt Dryer Sections Single-Felt Dryer Sections Gregory L. Wedel President Kadant Johnson Inc. Gerald L. Timm Vice President, Research & Development Kadant Johnson Inc. Kenneth C. Hill President Kadant Johnson Systems Division

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers e-issn 2455 1392 Volume 2 Issue 5, May 2016 pp. 108-116 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards

More information

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY PRIME COMMERCIAL CONDENSING GAS WATER HEATER 40-119 GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY WATER HEATERS TM (Optional) TM THE ULTIMATE IN CONDENSING GAS WATER HEATING THE PRIME ADVANTAGE Industry's

More information

Tepid Water Delivery System

Tepid Water Delivery System Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

SOLAR HEATING SYSTEMS

SOLAR HEATING SYSTEMS introducing SOLAR HEATING SYSTEMS TM the low carbon water heating system June 2008 Irl 1 In this environmentally challenging world, it s time to rethink our heating.....while we still have time. There

More information

Descaler & Prevention

Descaler & Prevention Descaler & Prevention Treatment Method for existing scaled surfaces like inside of piping, tubes, Heaters, boilers, sump wall etc. By Deepak Chopra Watch Water GmbH Fahrlachstraße 14 68165 Mannheim Germany

More information

KE2 EvaporatorEfficiency Theory of Operation

KE2 EvaporatorEfficiency Theory of Operation Theory T.1.1 June 011 TM thermsolutions ENTER BACK KE Therm Solutions, Advanced Energy Saving Technology for Commercial Refrigeration and AC Systems Page Table of Contents Basic Refrigeration System Evaporator

More information

SOLAR HOT WATER HEATERS

SOLAR HOT WATER HEATERS ALTERNATIVE ENERGY SOLAR HOT WATER HEATERS Solar Hot Water The shallow water of a lake is usually warmer than the deep water. That's because the sunlight can heat the lake bottom in the shallow areas,

More information

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS CONTENTS Overview 2 Features & Benefits 3 Performance 4 Accent Pool Water to Water Heat Pumps Technical 5 Accent Hot Water Water to Water Heat Pumps Technical

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Heat Pump Water Heater Commercial Leaflet 2012

Heat Pump Water Heater Commercial Leaflet 2012 Heat Pump Water Heater Commercial Leaflet 2012 1 Table of contents............... 2 Bosch Group Innovation as a principal Established in 1886 in Stuttgart, Germany, Robert Bosch Corporation has been characterised

More information

WHERE TO START SAVING ELECTRICITY ABOUT 40% OF HOUSHOLD ELECTRICITY IS USED HEATING WATER

WHERE TO START SAVING ELECTRICITY ABOUT 40% OF HOUSHOLD ELECTRICITY IS USED HEATING WATER WHERE TO START SAVING ELECTRICITY ABOUT 40% OF HOUSHOLD ELECTRICITY IS USED HEATING WATER CONVENTIONAL HOT WATER GEYSERS A conventional Hot Water Geyser is cheap to purchase compared to a solar system

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

Heat recovery systems. For hot air and hot water applications.

Heat recovery systems. For hot air and hot water applications. Heat recovery systems For hot air and hot water applications www.kaeser.com Heat recovery systems Why recover heat? The question should in fact be: Why not? Amazingly, practically 100 percent of the electrical

More information

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger

More information

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint Home Heating Guide Why Vaillant? Because they can reduce our heating bills and our carbon footprint Because we re here to help If you have any questions, please call 01634 292300. We can also give you

More information

Screw Water Cooled Chiller SCW210

Screw Water Cooled Chiller SCW210 Screw Water Cooled Chiller SCW210 Nominal Cooling Capacity 185.1 to1480.8 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

LAB EQUIPMENT DETAILS

LAB EQUIPMENT DETAILS DEPARTMENT OF MECHANICAL ENGINEERING LAB EQUIPMENT DETAILS S. N o Name of the Equipment Manufacturer Equipment Photo Description Applications Cost of the Equipment 1 Guarded plate The consists of main

More information

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm

More information

WHY A MHI HEAT PUMP?

WHY A MHI HEAT PUMP? HYDROLUTION HEATING HOT SANITARY WHY A MHI HEAT PUMP? Mitsubishi Heavy Industries Thermal Systems air to water heat pump is a complete modern system for heating, cooling and producing hot sanitary water

More information

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw GAS FIRED ATMOSPHERIC ELECTRONIC VERSION 51-102 kw GENERAL DESCRIPTION 900 D a3 1000 762 672 E 222 The PEGASUS F2 range of atmospheric natural gas-fired boilers are constructed of cast iron finned sections

More information

Safario Cooling Factory LLC

Safario Cooling Factory LLC Safario Cooling Factory LLC Since 1999, Safario Cooling Factory LLC has been maintaining as a leading manufacturer of Commercial and Industrial HVAC coils, chilled water coils, chiller coils, steam coils,

More information

1ST SUNFLOWER RENEWABLE ENERGY

1ST SUNFLOWER RENEWABLE ENERGY 1ST SUNFLOWER RENEWABLE ENERGY Brief Introduction about 1st Sunflower Balance Nature Basic elements for the Earth Human beings are born from nature, the nature satisfies with mind. So in the relationship

More information