Service Parts, Kits and Accessories

Size: px
Start display at page:

Download "Service Parts, Kits and Accessories"

Transcription

1 The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components not only used on current production, but also on equipment that is of earlier design. To use the guides properly, you should know the model numbers of the heater and its design sequence. This information is identified on the dataplate. Some models may have the design sequence shown as the 4th digit of the model number. For other models, the dataplate will identify a configuration number. The design sequence is the first digit of the configuration number. In many cases you will find components are common between different designs of the model number. Parts lists and schematics are shown on the following pages for the respective heaters. The parts guides also identify part numbers for the most commonly requested components, wires, and hardware items used on the heaters. If a wire, nut, or screw, etc. is not identified, please contact the L. B. White Co. for parts ordering information. Without Configuration Number MODEL 346K AW075EHP3 SERIAL NO.: Design Sequence Dataplate Comparison A DESI GN A MERI CERT C GA S SSOC A N I ON I AT I FI ED With Configuration Number MODEL AW060 AB250 CONFIGURATION NO. AHPD20000 APPD0004 SERIAL NO.: Design Sequence MAXIMUM INPUT: 75,000 60,000 BTUH TYPE FUEL: PROPANE VAPOR WITHDRAWAL BURNER MANIFOLD PRESSURE 0 IN W.C. AT MAXIMUM INPUT MAXIMUM INPUT: 60, ,000 BTUH TYPE FUEL: PROPANE VAPOR WITHDRAWAL BURNER MANIFOLD PRESSURE 0.0 IN W.C. AT MAXIMUM INPUT ELECTRICAL: 5 VOLTS A.C. 60 HZ SINGLE PHASE.4 AMPS MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR 6 FT IN. SIDES 6 FT IN. TOP TO CEILING 6 FT IN. BLOWER OUTLET 6 FT AND FUEL CONTAINER 6 FT VENTILATION: CFM OF AIR REQUIRED TO SUPPORT COMBUSTION. MAXIMUM 3.5 INCHES W.C. AND MINIMUM.5 INCHES W.C. GAS SUPPLY PRESSURE ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT. POSITION HEATER AWAY FROM LIVESTOCK AGRICULTURAL BUILDING HEATER ELECTRICAL: 5 VOLTS A.C. 60 HZ SINGLE PHASE.5 AMPS MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR FT SIDES FT TOP TO CEILING FT BLOWER OUTLET 6 FT AND FUEL CONTAINER 6 FT VENTILATION: CFM OF AIR REQUIRED TO SUPPORT COMBUSTION. MAXIMUM 3.5 INCHES W.C. AND MINIMUM.5 INCHES W.C. GAS SUPPLY PRESSURE ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT. POSITION HEATER AWAY FROM LIVESTOCK AGRICULTURAL BUILDING HEATER A DESI GN A MERI C CERT A N GA S ON ATI I I FI ED SSOC L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI / L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI / August

2 Model AS040 Item Description Design Sequence Part Number Regulator, Second Stage, Vent Over Side (LP Gas) A Regulator, Single Stage (Natural Gas) A Nipple, /2 x 3 /2 A Valve, Manual Shut-Off A Hose, /2 x 0 ft. A Sediment Trap A Adapter, /2 NPT x /2 NPS A Nipple, 3/8 x /2 A Bushing A Bolt A Valve, Gas Control (LP Gas or Natural Gas) A Cap, Pilot A Bracket, Terminal Strip A Terminal Strip A Cover, Terminal Strip A Manifold (LP Gas) A Manifold (Natural Gas) A Orifice, Burner (LP Gas) A Orifice, Burner (Natural Gas) A Burner A Thermocouple, 8 in. A Tube, Pilot A Orifice (LP Gas) A Orifice (Natural Gas) A Screw, Pilot A Pilot Assembly with Orifice (LP Gas) A Pilot Assembly with Orifice (Natural Gas) A Shield, Pilot (LP Gas) A Shield, Pilot (Natural Gas) A Switch, High Limit A Spacer A Clip A Door, Burner End () A Handle A Panel, Air Inlet A Panel, Motor Access A Case Assembly () A Housing, Fan A Fan Blade A Mount, Motor A Spacer A Motor A Chamber, Heat A Holder, Burner A Bracket, Manifold A Base A Cord, Power A () Specify fuel gas type and model number when ordering. WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH PART NO. Wire, Harness, High Limit Switch Black 20 in FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw Case August 999

3 Model AS INSTALLATION OF GAS TRAIN ASSEMBLY FOR NATURAL GAS ONLY 3 2 August

4 Models 346 and 348 Design Sequence Item Description Regulator, Single Stage (LP Gas) E X F X G X H X J X K X Part Number Regulator, Second Stage (LP Gas) X X X X X X Regulator, Single Stage (Natural Gas) X X X X X X Regulator, Second Stage (Natural Gas) X X X X X X Hose, /4 in. ID x 0 ft. X X X X X X Hose, /2 in. ID x 0 ft. X X X X X X Adapter, /4 NPT x 9/6-8 X X X X X X Valve, Manual Shut-Off X X X X X X Bushing, 3/8 NPT x /4 X X X X X X Bushing, /2 x /4 X X X X X X Nipple, /2 x /2 X X X X X X Bushing, /2 x 3/8 X X X X X X Nipple, 3/8 x /2 X X X X X X Adapter, /2 NPT x /2 NPS X X X X X X Thermostat with Bracket X X X X X X Junction Box X X X X X X Cover, Junction Box X X X X X X Cord, Power, 5 ft. X X X X X X Bracket, Thermostat X X X X X X Valve, Pilot Gas Control (LP Gas or Natural Gas) () () X X X N/A Valve, Pilot Gas Control (LP Gas) N/A N/A N/A N/A N/A X F Valve, Pilot Gas Control (Natural Gas) N/A N/A N/A N/A N/A X Cap, Pilot, Gas Control Valve N/A N/A X X X N/A Orifice, Burner (LP Gas) X X X X X X Orifice, Burner (Natural Gas) X X X X X X Burner Casting N/A N/A X X X X Burner Casting X X N/A N/A N/A N/A Pilot Assembly with Orifice (LP Gas) X X X X X X Pilot Assembly with Orifice (Natural Gas) X X X X X X Orifice, Pilot (LP Gas) X X X X X X Orifice, Pilot (Natural Gas) X X X X X X Shield, Pilot X X X X X X Tube, Pilot with Nuts X X X X X N/A Tube, Pilot with Nuts N/A N/A N/A N/A N/A X Thermocouple, 2 in. X X X X X X Base X X X X X Base N/A N/A N/A N/A N/A X Motor X X X X X X Mount, Motor (2) (2) X X X x Wheel, Fan X X X X X X Housing, Fan X X X X X X Switch, High Limit X X X X X X Cover, High Limit X X X X X X Case, Assembly X X X X X X (3) 33 Handle X X X X X X Chamber, Heat X X X X X N/A Chamber, Heat N/A N/A N/A N/A N/A X Bracket, Gas Control Valve N/A N/A N/A N/A N/A X Cover N/A N/A N/A N/A N/A X Sediment Trap X X X X X X () For replacement control valve, order conversion kit part (2) Not used on E and F designs. (3) Specify fuel gas type and model number when ordering. N/A Not Applicable. WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, High Limit Black 25 in. All FASTENER SELECTION TABLE DESCRIPTION APPLICATION DESIGN PART NO. Screw, 8 x 3/4 Sheet Metal High Limit Switch, Mounting All Screw, 0-24 x /4 Machine Burner Mounting E-J Bolt, 3/8-6 x 5/8 Gas Control Valve to Base E-J Spacer Gas Control Valve to Base E-J Screw All Other Applications All Washer Burner Mounting K Screw Burner Mounting K August 999

5 Models 346 and TO NATURAL GAS SUPPLY 0 SEDIMENT TRAP KIT OPTIONAL ACCESSORY 4 August

6 Models 377 and 379 Design Sequence Item Description E F G H J K Part Number Regulator, Single Stage (LP Gas) X X X X X N/A Regulator, Single Stage (LP Gas) N/A N/A N/A N/A N/A X Regulator, Second Stage (LP Gas) X X X X X X Regulator, Single Stage (Natural Gas) X X X X X X Adapter, Hose, 3/8 NPT x /2 NPS X X X X X N/A Adapter, Hose, /2 NPT x /2 NPS N/A N/A N/A N/A N/A X Hose, /2 in. ID x 0 ft. X X X X X X Junction Box X X X X X X Cover, Junction Box X X X X X X Thermostat with Bracket X X X X X X Bracket X X X X X X Cord, Power, 5 ft. X X X X X X Cord, Power, 0 ft. X X X X X X Base, Terminal Board X X X X X N/A Cover, Terminal Board X X X X X N/A Valve, Manual Shut Off X X X X X X Nipple, /2 x /2 X X X X X N/A Valve, Gas Control (LP Gas or Natural Gas) () () X X X N/A Valve, Gas Control (LP Gas) N/A N/A N/A N/A N/A X Valve, Gas Control (Natural Gas) N/A N/A N/A N/A N/A X Cap, Pilot X X X X X N/A Bushing, Reducing X X X X X N/A Tube, Pilot with Nuts X X X X X N/A Tube, Pilot with Nuts N/A N/A N/A N/A N/A X Orifice, Pilot (LP Gas) X X X X X X Orifice, Pilot (Natural Gas) X X X X X X Pilot Assembly with Orifice (LP Gas) X X X X X X Pilot Assembly with Orifice (Natural Gas) X X X X X X Thermocouple, 2 in. X X X X X X Shield, Pilot X X X X X N/A Shield, Pilot N/A N/A N/A N/A N/A X Holder, Orifice X X X X X N/A Orifice, Burner (LP Gas) X X X X X N/A Orifice, Burner (Natural Gas) X X X X X N/A Orifice, Burner (LP Gas) N/A N/A N/A N/A N/A X Orifice, Burner (Natural Gas) N/A N/A N/A N/A N/A X Manifold, U-Shape X X X X X N/A Manifold, Welded N/A N/A N/A N/A N/A X Burner, Casting X X X X X X Gasket N/A N/A N/A N/A N/A X Screw, Burner Mounting X X X X X X Stud, Pilot N/A N/A N/A N/A N/A X Screw, Pilot X X X X X X Spacer, Burner X X X X X X Switch, High Limit X X X X X X Washer X X X X X N/A Chamber, Heat X X X X X X Case, Assembly X X X X X X (2) 34 Panel, Case, Burner End X X X X X X (2) 35 Panel, Case, Opposite Burner X X X X X X Ring, Inlet N/A N/A X X X X Fan, Wheel X X X X X X Flapper N/A N/A X X X X Housing, Fan with Air Proving Switch and Flapper X X X X X X Switch, Air Proving N/A N/A X X X X Motor X X X X X X Base X X X X X X Washer X X X X X X Bolt, Burner X X X X X N/A Bolt, Burner N/A N/A N/A N/A N/A X Bracket, Gas Control Valve N/A N/A N/A N/A N/A X Screw N/A N/A N/A N/A N/A X Spacer, Nylon N/A N/A N/A N/A N/A X Sediment Trap X X X X X X () For replacement control valve, order conversion kit part (2) Specify fuel gas type and model number when ordering. N/A 9.-6 Not Applicable. FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw, # 8 x 3/8 Case Assembly WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, Thermostat to Black 6 in. All Terminal Board Wire, High Limit Switch Black 25 /4 in. All Wire, Air Flow Switch Black 4 in. All August 999

7 Models 377 and NATURAL GAS SUPPLY SEDIMENT TRAP KIT OPTIONAL ACCESSORY August

8 Models 408 and 40 Design Sequence Item Description E F G H J K Part Number Regulator, Single Stage (LP Gas) X X X X X X Regulator, Second Stage (LP Gas) X X X X X X Regulator, Single Stage (Natural Gas) X X X X X X Regulator, Second Stage (Natural Gas) X X X X X X Hose, /2 in. x 0 ft. X X X X X X Adapter, /2 NPT x /2 NPS X X X X X X Valve, Manual Shut Off X X X X X X Nipple, /2 in. x 3 /2 in. X X X X X X Elbow X X X X X X Valve, Gas Control (LP Gas and Natural Gas) () () X X X N/A Valve, Gas Control (LP Gas) N/A N/A N/A N/A N/A X Valve, Gas Control (Natural Gas) N/A N/A N/A N/A N/A X Cap, Pilot Safety X X X X X N/A Bushing X X X X X N/A Nipple, /4 in. x 3 in. X X X X X N/A Holder, Orifice X X X X X N/A Orifice, Burner (LP Gas) X X X X X N/A Orifice, Burner (Natural Gas) X X X X X N/A Orifice, Burner (LP Gas) N/A N/A N/A N/A N/A X Orifice, Burner (Natural Gas) N/A N/A N/A N/A N/A X Screw N/A N/A N/A N/A N/A X Spacer, Nylon N/A N/A N/A N/A N/A X Manifold N/A N/A N/A N/A N/A X Bracket N/A N/A N/A N/A N/A X Thermocouple, 2 in. X X X X X X Tube, Pilot with Nuts X X X X X N/A Tube, Pilot with Nuts N/A N/A N/A N/A N/A X Orifice, Pilot (LP Gas) X X X X X X Orifice, Pilot (Natural Gas) X X X X X X Pilot Assembly with Orifice (LP Gas) X X X X X X Pilot Assembly with Orifice (Natural Gas) X X X X X X Gasket, Pilot N/A N/A X X X X Shield, Pilot (LP Gas) X X X X X N/A Shield, Pilot (Natural Gas) X X X X X N/A Shield, Pilot (LP and Natural Gas) N/A N/A N/A N/A N/A X Burner (LP Gas) X X X X X (2) Burner (Natural Gas) X X X X X N/A Spacer, Burner X X X X X X Cord, Power, 5 ft. X X X X X X Cord, Power, 0 ft. X X X X X X Bracket, Thermostat X X X X X X Stud, Pilot N/A N/A N/A N/A N/A X Screw, Pilot X X X X X X Washer X X X X X X Bolt X X X X X N/A Bolt N/A N/A N/A N/A N/A X Thermostat with Bracket X X X X X X Cover, Junction Box X X X X X X Junction Box X X X X X X Cover, Terminal Board X X X X X N/A Base, Terminal Board X X X X X N/A Screw, Burner X X X X X X Switch, High Limit X X X X X X Washer X X X X X N/A Chamber, Heat X X X X X X Case Assembly X X X X X X (3) 4 Panel, Case, Burner End X X X X X X (3) 42 Panel, Case, Motor End X X X X X X Motor X X X X X X Mount, Motor N/A N/A X X X X Switch, Air Proving N/A N/A X X X X Flapper N/A N/A X X X X Fan, Wheel X X X X X X Housing with Air Proving Switch and Flapper N/A N/A X X X X Base X X X X X X Sediment Trap X X X X X X () For replacement control valve, order conversion kit part # (2) Part # is used for LP and Natural Gas on K design heaters. (3) Specify fuel gas type when ordering. N/A Not Applicable FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw, # 8 x 3/8 Case Assembly WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, Thermostat to Black 2 /2 in. All Terminal Board Wire, Air Flow Switch Black 42 in. All Wire, High Limit Switch Black 25 /4 in. All August 999

9 Models 408 and NATURAL GAS SUPPLY SEDIMENT TRAP KIT OPTIONAL ACCESSORY August

10 Model AB200 Design Sequence Item Description A B Part Number Regulator, Second Stage (LP Gas) X X Regulator (Natural Gas) X X Nipple, /2 x 3 /2 X X Valve, Manual Shut-Off X X Hose, /2 in. ID x 0 ft. X X Adapter, Hose X X Kit, Sediment Trap X X Nipple, /2 x /2 X X Valve, Pilot Gas Control (LP Gas or Natural Gas) X X Cap, Pilot X X Manifold, Welded X X Orifice, Burner (LP Gas) X X Orifice, Burner (Natural Gas) X X Thermocouple, 8 in. X X Tube, Pilot, with Nuts X X Orifice, Pilot (LP Gas) X X Orifice, Pilot (Natural Gas) X X Screw, Wing X X Bracket, Pilot X X Screw, Burner Mounting X X Spacer, Burner X X Shield, Pilot with Pilot Stack X X Casting, Burner X X Stud, Pilot Mounting X X Cover, Terminal Strip N/A X Bracket, Terminal Strip N/A X Strip, Terminal N/A X Cover, Terminal Board X N/A Board, Terminal X N/A Switch, High Limit X X Chamber, Heat X X Bracket, Flame Lift Off X X Case Assembly X X () 3 Door, Access, Right X X ( ) 32 Door, Access, Left X X Hinge X X Latch X X Motor X X Mount, Motor X X Wheel, Fan X X Flapper X X Switch, Air Proving X X Housing with Air Proving Switch and Flapper X X Base X X Bolt X X Washer X X Cord, Power X X () Specify fuel gas type and model number when ordering. WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH DESIGN PART NO. Wire, Air Proving Switch to Terminal Board Black 42 in. All wire, High Limit Switch Black 25 /4 in. All Wire, Thermostat to Terminal Board Black 2 /2 in. All FASTENER SELECTION TABLE DESCRIPTION APPLICATION PART NO. Screw, #8 x 3/8 Case Assembly August 999

11 Model AB NATURAL GAS SUPPLY August

12 Model AB250 Design Sequence Item Description A Part Number Regulator, Second Stage, Vent Over Side (LP Gas) X Regulator, Second Stage (Natural Gas) X Nipple, 3 /2 in. X Valve, Manual Shut-Off X Adapter, Hose, /2 NPT x /2 NPS X Hose, /2 in. ID x 0 ft. X Kit, Sediment Trap X Base X Bracket, Gas Control Valve X Bolt X Valve, Gas Control (LP Gas) X Valve, Gas Control (Natural Gas) X Nipple, /2 in. x /2 in. X Valve, Throttle (LP Gas) X Valve, Throttle (Natural Gas) X Ell, Street X Manifold X Orifice, Burner (LP Gas) X Orifice, Burner (Natural Gas) X Gasket, Pilot X Thermocouple, 2 in. X Tubing, Pilot X Orifice, Pilot (LP Gas) X Orifice, Pilot (Natural Gas) X Cover, Pilot (Bottom) X Screw, Wing X Stud X Pilot, Bracket X Shield, with Pilot Barrel X Terminal Strip X Enclosure, Electrical X Cover, Electrical X Screw X Burner X Spacer X Switch, High Limit X Chamber, Heat X Door, Left or Right X Cord, Power X Latch X Hinge X Case Assembly X () 38 Motor X Mount, Motor X Wheel, Fan X Switch, Air Proving X Flapper (Sail) X Housing, Fan, with Flapper, Air Proving, and Motor Mount X () Specify fuel gas type and model number when ordering. NOTE: For fixed rate heater, replace items, 2 and 3 with a /2 in. elbow, part number and nipple, /2 in. x 3 /2 in., part number WIRE SELECTION TABLE DESCRIPTION COLOR LENGTH PART NO. Wire, Gas Control to Terminal Strip White 24 in Wire, Air Flow Switch to Terminal Strip Black 45 in FASTENER SELECTION TABLE Wire, High Limit Switch DESCRIPTION APPLICATION PART NO. to Air Flow Switch Black 60 in Bolt Burner Mounting August 999

13 Model AB August

14 This section provides part numbers for many of the more commonly requested kits and accessories used on pilot light ignition heaters. GAS CONVERSION KITS Control Valves without Internal Low Pressure Regulators and Gas Shut Offs (Control Valve Part # ) PART PROPANE TO NATURAL GAS NUMBER MODEL NUMBER DESIGN(S) G, H and J G, H and J G, H and J AB200 A AS040 A NATURAL GAS TO PROPANE G, H and J G, H and J G, H and J AB200 A AS040 A GAS CONVERSION KITS Control Valves with Internal Low Pressure Regulators and Gas Shut Offs PART PROPANE TO NATURAL GAS NUMBER MODEL NUMBER DESIGN(S) K K K AB250 A NATURAL GAS TO PROPANE K K K AB250 A 9.2- August 999

15 PART NUMBER TEST KITS DESCRIPTION Low Gas Pressure Test Kit Thermocouple Test Kit PART NUMBER MISCELLANEOUS KITS DESCRIPTION Indoor Chain Hanging Kit DESCRIPTION AIR DIVERTERS MODELS PART NUMBER Two Piece (Snap-In) 346, AB200, 377, 379, 408, AB One Piece 346, AB200, 377, 379, 408, DESCRIPTION THERMOSTATS Remote Thermostat - Penn Stainless Steel (Less Wiring) Remote Thermostat - Penn Stainless Steel w/20' Series Tap Cord Remote Thermostat - Nema 4X w/20' Series Tap Cord Remote Thermostat - Nema 4X Meets NEC Article 547 (Less Wiring) PART NUMBER August

16

17 Warranty Guidelines Equipment and Parts EQUIPMENT L.B. White Co., Inc. warrants that the component parts of its heater are free from defects in material and workmanship, when properly installed, operated, and maintained in accordance with the Installation and Maintenance Instructions, safety guides and labels contained with each unit. If, within 2 months from the date of purchase by the end user, any component is found to be defective, L.B. White Co., Inc. will at its option, repair or replace the defective part or heater, with a new part or heater, F.O.B., Onalaska, Wisconsin. A warranty card on file at L.B. White will automatically qualify a unit and its component parts for warranty consideration. If a warranty card is not on file, a copy of the bill of sale will be required to establish warranty qualification. If neither is available, the warranty period will be 2 months from date of shipment from L B. White. PARTS L.B. White Co., Inc. warrants that replacement parts purchased from the company and used on the appropriate L.B. White heaters are free from defects both in material and workmanship for 2 months from the date of purchase by the end user. Warranty is automatic if a component is found defective within 2 months of the date code marked on the part. If the defect occurs more than 2 months later than the date code but within 2 months from the date of purchase by the end user, a copy of a bill of sale will be required to establish warranty qualification. The warranty set forth above is the exclusive warranty provided by L.B. White, and all other warranties, including any implied warranties or merchantability or fitness for a particular purpose, are expressly disclaimed. In the event any implied warranty is not hereby effectively disclaimed due to operation of law, such implied warranty is limited in duration to the duration of the applicable warranty stated above. The remedies set forth above are the sole and exclusive remedies available hereunder. L.B. White will not be liable for any incidental or consequential damages directly or indirectly related to the sale, handling or use of the heater, and in any event L.B. White's liability in connection with the heater, including for claims based on negligence or strict liability, is limited to the purchase price. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. REPLACEMENT PARTS AND SERVICE Contact your local L.B. White dealer for replacement parts and service or call the L.B. White Co., Inc. at for assistance. Be sure that you have your heater model number and configuration number when calling. August

18 Warranty Guidelines Warranty Returns Warranty Returns To complement L.B. White s warranty, the following has been written to simplify the warranty return policy. Our goal is to process warranty returns and issue the appropriate credit to you as promptly as possible. Your cooperation in following the procedures listed below will help us achieve our goal.. Units and Sub-Assemblies A. Defective heaters and sub-assemblies may be returned to L.B. White by authorized L. B. White service dealers by obtaining factory approval and a Return Authorization Number prior to any return shipment. The following information must be supplied when requesting a Return Authorization Number:. Complete heater model and serial number 2. Customer's name and address 3. Date sold 4. Date installed 5. Date failed 6. Probable cause of equipment failure 0.2- B. The Return Authorization Number must be shown on all transmitting paperwork and marked on the outside of the merchandise return carton. A warranty card on file at L.B. White will automatically qualify the unit, sub-assembly, or component for a 2-month warranty from date of purchase if the material being returned is found defective. Items must be returned freight PREPAID. Return of New Items for Credit. Factory Approval Factory approval and a Return Authorization Number must be obtained before any new product or part is returned to L. B. White or credit may not be issued. 2. Freight All items returned for credit must be shipped freight prepaid. 3. Restocking Charge A 5% restocking charge will apply provided the item is new and in unused condition. Additional charges will be made if reconditioning or new packaging is required. Shipping Damage. Parcel Post All Parcel Post claims for damages or shortages must be made to L.B. White within 20 days of date of shipment. 2. Parts Authorized L.B. White service dealers can return defective service parts, qualified for warranty under the L.B. White Warranty Policy, as follows: A. By using L.B. White Material Return Tags. Prior factory approval is not required in this case. A Material Return Tag must be filled out completely and attached to each defective part being returned. Material Return Tags are available from L. B. White upon request. B. By using the Return Authorization Number procedure described in A. above. All items must be returned freight PREPAID. Out of warranty parts require factory approval and a Return Authorization Number prior to being returned. 3. Credit Credit will be issued if inspection indicates: A. The item is defective B. The item is within the warranty period C. Failure is due to normal use L.B. White is not responsible for the labor cost of removal of a defective product or part, or damages due to removal, or expenses incurred in shipping the product or part to or from L.B. White's plant, or the installation of the repaired or replaced product or part. 4. Item Shipped Incorrectly If the item was shipped in error, L.B. White will authorize shipping freight collect and rescind the 5% restocking charge if Step above is followed. 5. Materials Return Tag All parts returned to L.B. White must be accompanied by a Materials Return Tag with the Return Authorization Number. A separate tag is required for each part. 2. Truck or United Parcel Service Damage claims should be made by the customer directly to the carrier or UPS. August 999

Ransome Direct Fired Vaporizers VAPORIZERS & HEATERS RH240 RH50, RH80 & RH120. Direct-Fired LP-Gas Vaporizer. RH200 thru RH1000

Ransome Direct Fired Vaporizers VAPORIZERS & HEATERS RH240 RH50, RH80 & RH120. Direct-Fired LP-Gas Vaporizer. RH200 thru RH1000 Ransome Direct Fired Vaporizers RH50, RH80 & RH120 The RH Series vaporizer consists of a vertical ASME pressure vessel that is directly heated by a gas fired burner. Millivolt powered burner controls maintain

More information

Owner's Manual and Instructions

Owner's Manual and Instructions Owner's Manual and Instructions Norseman Heavy Duty Convection Construction Heaters MODEL OUTPUT (Btuh) FUEL 322 200,000 L.P. Gas Vapor Withdrawal Congratulations! You have purchased the finest convection

More information

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION G Series (Model B) Convector Heater for Hazardous Locations Type G-Series Convection Heaters are designed for use in Class I, Div. I hazardous environments. Units without control options are suitable for

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS Printed in U.S.A. INSTALLATION AND OPERATION INSTRUCTIONS RFPA21A CONSTRUCTION HEATER FLOOR MODEL SAVE FOR FUTURE REFERENCE Space-Ray Division, Gas Fired Products, Inc. P.O. Box 36485, Charlotte, NC 28236

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

Owner's Manual and Instructions

Owner's Manual and Instructions Owner's Manual and Instructions Tradesman Construction Heater MODELS OUTPUT (Btuh) FUEL CP100 100,000 Propane Vapor Withdrawal Certification by: Congratulations! You have purchased the finest construction

More information

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER RBDS-1 RBD SERIES CERAMIC HEATERS NATURAL GAS (Check One) PROPANE GAS EQUIPMENT USED: ACCESSORIES: Chain Mounting Kit: Thermostat: Gas Pressure Regulator: Parabolic Extension: Gas Shut-Off Valve: Reverb

More information

FOR EASY, FAST INSTALLATION AND FOR RESULTS

FOR EASY, FAST INSTALLATION AND FOR RESULTS Page 1 INSTALLATION & OPERATING INSTRUCTIONS FOR FEDERAL FLOOR FURNACE OFB-100 AND OFB100L UNPACK SHIPMENT CAREFULLY AND INSPECT FOR DAMAGE. ALL GOODS ARE CAREFULLY MANUFACTURED, INSPECTED, CHECKED, AND

More information

Owner's Manual and Instructions

Owner's Manual and Instructions Owner's Manual and Instructions Workman Convection Construction Heaters MODELS OUTPUT (Btuh) FUEL CV225 225,000 Propane Vapor Withdrawal Certification by: Congratulations! You have purchased the finest

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS Printed in U.S.A. INSTALLATION AND OPERATION INSTRUCTIONS RFPA10C CONSTRUCTION HEATER FLOOR MODEL SAVE FOR FUTURE REFERENCE Space-Ray Division, Gas Fired Products, Inc. P.O. Box 36485, Charlotte, NC 28236

More information

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key ASSEMBLY and INSTALLATION INSTRUCTIONS Gas Conversion Kit Tube Heaters View these instructions online at www.lbwhite.com Kit Contents: DESCRIPTION QTY. Instructions 1 Burner orifi ce 1 Manifold pipe 1

More information

Construction Heater GENERAL HAZARD WARNING

Construction Heater GENERAL HAZARD WARNING Dayton Operating Operating Instructions Instructions & Parts and Parts Manual Manual Model Dayton Natural Gas Construction Heater Please read and save these instructions. Read carefully before attempting

More information

CINCINNATI, OH USA

CINCINNATI, OH USA INSTRUCTION MANUAL Part No. 89731 Revised October 1997 CINCINNATI, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier.

More information

Owner's Manual and Instructions

Owner's Manual and Instructions Owner's Manual and Instructions Tradesman Kerosene Heaters MODELS OUTPUT (BTUH) FUEL CP125BK 125,000 CP170BK 170,000 CP210BK 210,000 1-K Kerosene Certification by: Congratulations! You have purchased the

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-30P-DDF, CL-20F-DDF, CL-24O-DDF, CL-30-DDF READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: PT-18W-DDF-A, PT-20F-DDF-A, PT-20S-DDF, PT-24O-DDF, PT-24-DDF, PT-24-DDF-F, PT-30-DDF, PT-30P-DDF-A, PT-30P-DDF-AF READ AND SAVE THESE INSTRUCTIONS

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

Parts List for Ener-Radiant XL Tube Heaters

Parts List for Ener-Radiant XL Tube Heaters Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.

More information

M-11 Series. Installation and Service Manual

M-11 Series. Installation and Service Manual M-11 Series Installation and Service Manual INTRODUCTION SPECIFICATIONS UNPACKING MOUNTING ELECTRICAL OPERATION MAINTENANCE REPLACEMENT PARTS TROUBLESHOOTING ***IMPORTANT*** THIS MANUAL CONTAINS PRECAUTIONARY

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

GENERATION 2 QUADRATHERM Heater

GENERATION 2 QUADRATHERM Heater GENERATION 2 QUADRATHERM Heater FOR YOUR SAFETY If you smell gas: 1. Open Windows 2. Do not touch electrical switches 3. Extinguish any open flames 4. Immediately call your gas supplier FOR YOUR SAFETY

More information

Desiccant / Pump Dehumidification System. Model Operating Manual

Desiccant / Pump Dehumidification System. Model Operating Manual Desiccant / Pump Dehumidification System Model 5471 Operating Manual 6/30/06 www.electrotechsystems.com TABLE OF CONTENTS Model 5471 Desiccant / Pump Dehumidification System PARAGRAPH DESCRIPTION PAGE

More information

Hot Surface Ignition. Agricultural Animal Confinement Building Heaters. Installation and Service Guide

Hot Surface Ignition. Agricultural Animal Confinement Building Heaters. Installation and Service Guide Hot Surface Ignition Agricultural Animal Confinement Building Heaters Installation and Service Guide 150-21516 Foreword The purpose of this Service Guide is to provide detailed instructions and information

More information

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS IMPORTANT INFORMATION Warnings 2 Installation Instructions 3 Wiring Instructions 3 Outdoor

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG 24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas draft induced appliances with a 24 VAC Gas Valve and a 30-millivolt

More information

WARMING AND MERCHANDISING CABINET

WARMING AND MERCHANDISING CABINET WARMING AND MERCHANDISING CABINET Above red graphics now replace green graphics shown in photo. MODEL 695 (Single door unit shown) MODEL 695-S (Single door unit shown) Snack foods have to be hot and moist

More information

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS REVOLUTION L-360-CD & L-420-CD SERIES If for any reason, you cannot follow these instructions, FOR ANY REASON WHATSOEVER, just return the product to your dealer,

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL dickinson since 1932 MODEL 00-NEW-P12000 INSTALLATION AND OPERATING MANUAL Manufactured by: Dickinson Marine (1997) Ltd, 407-204 Cayer Street, Coquitlam, British Columbia, Canada V3K 5B1 www.ahoycaptain.com

More information

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

ICS Float and Thermostatic Steam Trap Installation and Operation Manual ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.

More information

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS CSA Model98900 DRS02403 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas:

More information

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C PROJECT: INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS (CHECK ONE) RSTP17C NAME: ADDRESS: (CHECK ONE) PROPANE GAS DATE: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: NAME: ADDRESS: EQUIPMENT

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop Instruction Manual Cheddar Easy All-In-One Cheese Corn Shop Model No. 2703-00-000 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2017 Gold Medal Products Co. Part No. 110028 SAFETY PRECAUTIONS

More information

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL THIS PAGE INTENTIONALLY LEFT BLANK. Section TABLE OF CONTENTS Page Section 1. TROUBLESHOOTING... 1-1 1-1. Introduction... 1-1 1-2.

More information

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

Quantity X Section Assembly (Intermittent and Continuous Circulation Only) V. Repair Parts Section Assembly and Canopy Group...30 Base Assembly...3 Manifold and Main Burners Inch Main Burners...34 40mm Main Burners...36 Pilot Burner and Gas Valve Continuous Ignition (Standing

More information

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST WF WAVE SERIES: WF AND WF 0 PIZZA OVENS REPLACEMENT S LIST EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are

More information

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective Commercial Water Heater Replacement Parts Price List For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB Prices Effective October 2, 2006 This parts price catalog supercedes book number SCBPB00306 and all

More information

MODEL CDB8 INSTALLATION INSTRUCTIONS

MODEL CDB8 INSTALLATION INSTRUCTIONS REV 0417 TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com SUITABLE FOR SIDE WALL OR

More information

DH Series Portable Industrial Unit Blower Air Heaters

DH Series Portable Industrial Unit Blower Air Heaters DH Series Portable Industrial Unit Blower Air Heaters Installation, Operation & Maintenance Instructions Table A- Model Specification and Cable / Plug Selection WIRIN 25 ft OPTIONAL PLUS MODEL DIARAM SHIP

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output Operating Instructions & Parts Manual 1RKT2, 1RKT3, 1RKT4, 1RKT5, 1RKT9 and 1RKU2 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS MODELS 170F, 174F & 178F FAN FORCED WALL HEATERS FINISH ASSEMBLIES FOR USE WITH BROAN MODEL 171H ROUGH-IN HOUSING READ AND SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLING

More information

WARMING AND MERCHANDISING CABINET

WARMING AND MERCHANDISING CABINET WARMING AND MERCHANDISING CABINET MODEL 695 MODEL 695-S (Two door unit shown) (Single door unit shown) Snack foods have to be hot and moist to be appealing. Cold won t do... Dry won t do. Wisco s model

More information

W6636 East Avenue North, Onalaska, WI USA (608) Fax: (608)

W6636 East Avenue North, Onalaska, WI USA (608) Fax: (608) W6636 East Avenue North, Onalaska, WI USA (608) 781-8500 Fax: (608) 783-6115 F150-81033-B-09 2 3 GAZ PLYNNY 25 I 3P GAZ BUTANOWY 20 I 3B/P 10 I 2H, I 2E, and I 2E(S)B, GAZ ZIEMNY 4 Kategoria i cisnienie

More information

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual Model, 2025BN, 2025ST Staging Cabinets Instruction Manual Part No 53021 Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS DANGER Machine must be properly grounded to prevent electrical shock to personnel.

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

More information

MN908 No. 282C Replaces 282B LB7013

MN908 No. 282C Replaces 282B LB7013 No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

Installation and Maintenance "L" and "LS" Series

Installation and Maintenance L and LS Series Installation and Maintenance "L" and "LS" Series IB-43-E This bulletin should be used by experienced personnel as a guide to the installation and maintenance of "L" and "LS" Series ultra capacity float

More information

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

The Economical, Unitary Infrared Heater Submittal: BH Series

The Economical, Unitary Infrared Heater Submittal: BH Series Blackheat BH The Economical, Unitary Infrared Heater Submittal: BH Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO.

More information

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CSA Model 98300 DRF01000 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1.

More information

Sound Cover [ , , , ]

Sound Cover [ , , , ] Sound Cover [77001603, 77001604, 77001605, 77001606] Intended Use: To provide lower sound (dba) levels for Midmark PowerAir Compressors. Requirements / Restrictions: After cover is mounted to compressor,

More information

Power Direct Vent PDV(S&T) Models

Power Direct Vent PDV(S&T) Models COMMERCIAL REPLACEMENT PARTS LIST Power Direct Vent PDV(S&T) Models Includes Hydrojet Total Performance System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING

More information

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.), Hanover Outdoor Furniture IMPORTANT If you have any problems with this product (missing or damaged parts, assembly issues, etc.), PLEASE DO NOT RETURN TO THE RETAILER/STORE from where you purchased the

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5 TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance

More information

MaxLite LED Vapor Tight Linear Fixture

MaxLite LED Vapor Tight Linear Fixture General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL TABLE OF CONTENTS PAGE # SAFETY INSTRUCTIONS......... 2 INSTALLATION INSTRUCTIONS................... 3 CABINET LOCATION GUIDELINES...

More information

THC- 355DF (Dual Fuel)

THC- 355DF (Dual Fuel) OPERATING INSTRUCTIONS MANUAL THC- 355DF (Dual Fuel) INDUSTRIAL / COMMERCIAL DIRECTIONAL SPACE HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCES) Certified to / Certifié à ANSI std Z83.7 2000 Suitable

More information

CPL Series Pedestal Convection Heater

CPL Series Pedestal Convection Heater Installation Instructions and RENEWAL PARTS IDENTIFICATION CPL Series Pedestal Convection Heater MODEL CPLAS (H=5-1/2, D=3 ) CAT. LENGTH WATTS/ TOTAL AMPERAGE NO.* L Ft. WATTS 120V 208V 240V 277V 2125

More information

Construction Heater GENERAL HAZARD WARNING

Construction Heater GENERAL HAZARD WARNING Dayton Operating Operating Instructions Instructions & Parts and Parts Manual Manual Model Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain

More information

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00 I&M NUMBER: 316-42-16-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) MP GS/GD 0 GAS Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # Moisture Plus Gas GS/GD0 (Rev 5) Page 2 FORM # Moisture Plus

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. WARNING: If the information in this manual is not followed exactly, a fire

More information

Repeat procedures for other side.

Repeat procedures for other side. Repeat procedures for other side. ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model 98900 Printed in China DANGER

More information

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER A Division of THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented /

More information

MaxLite LED Round Pendant Highbay Series

MaxLite LED Round Pendant Highbay Series General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

MODEL 995 STEAM TABLE

MODEL 995 STEAM TABLE FOOD WARMING/MERCHANDISING CABINET MODEL 995 Steam Table MODEL 995 STEAM TABLE The Model 995 Warmer/Merchandiser provides an ideal environment for promoting and preserving the freshness of soft pretzels,

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Portable High Temperature Blower Attention: Do not operate this heater in explosive areas. Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater

More information

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER INFRARED RADIANT TUBE HEATER LTU 40 250 SERIES PROJECT: ADDRESS: ARCHITECT/ENGINEER: ADDRESS: CONTRACTOR: ADDRESS: SUBMITTED BY: N-NATURAL GAS (CHECK ONE) L-PROPANE GAS EQUIPMENT USED: 5-SINGLE STAGE (CHECK

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS CSA Model: 98910L Printed in China Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. WARNING: If the information in this manual

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation

More information

Electric Space Heater

Electric Space Heater The Choice of Professionals Model No. FUH Series Electric Space Heater Installation & Maintenance Instructions SPECIFICATIONS: FUH 54B Heater Rating and Voltage 5000 W @ 40V 465W @ 40V 333W @ 40V 500W

More information

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION. SYSTEM CONTROL KIT Model: CK-20F and CK-20FG (NOTE: CK-20FG units are designed for the Flame Guard units built by American Water Heater. All other manufacturers use CK-20F) Designed for use with the SWG

More information

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount. Recessed Mount Ceiling Mounted Fan Forced SERIES 500 Surface Mount Installation & Maintenance Instructions Dear Owner, Congratulations Thank you for purchasing this new heater manufactured by Marley Engineered

More information

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE DR-180 Through the Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT

More information

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT ) 006 Perimeter Road. Greenville, SC 9605 Toll Free: 800/5-90 - Phone: 86/77-5870 Fax: 86/5-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/McLaughlin

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

Low-Intensity, Infrared Heating Systems Submittal: HE Series

Low-Intensity, Infrared Heating Systems Submittal: HE Series Low-Intensity, Infrared Heating Systems Submittal: HE Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT

More information

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000 SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual 65 SH-2500 SH-2000 AB-3000 Table of Contents General Safety Information.............. 2 Product Information..................3

More information

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan Soleus Air Ultra Quiet Ventilation Fan Model No: FE1-05 / FE1-07 / FE1-09 / FE1-11 50 CFM / 70 CFM / 90 CFM / 110 CFM Operating Instructions FE1-05-01 FE1-07-01 FE1-09-01 FE1-11-01 ####### 3092716 FE1

More information

Condensate Pump. Installation and Safety Instructions CP-16 CP

Condensate Pump. Installation and Safety Instructions CP-16 CP Condensate Pump Installation and Safety Instructions CP-16 CP-16-230 CP-16 CP-16-230 Rated Voltage 120 Volts / 60 Hz 220 Volts / 60 Hz (208-230) Rated Current Draw 1.9 Amps 1.0 Amps Input Type USA 3-prong

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions IMPORTANT INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Saving energy and creating healthy, comfortable environments No. II-450 Date July, 2015 DRIVE-THRU UNIT 3 AIR CURTAIN SERIES DTU03 for outdoor use

More information

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL Section TABLE OF CONTENTS Page Section 1. TROUBLESHOOTING... 1-1 1-1. Introduction... 1-1 1-2. Safety... 1-1 1-3. Troubleshooting...

More information

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS Please read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans... The

More information

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET FOOD WARMING/ MERCHANDISING CABINET MODEL 925W This warmer/merchandiser provides heated circulating air to keep foods fresh and evenly warmed. It is constructed of stainless steel and tempered glass for

More information

LEAVE THIS MANUAL WITH HOMEOWNER

LEAVE THIS MANUAL WITH HOMEOWNER READ AND SAVE THESE INSTRUCTIONS. MODEL A24DD DIRECT DRIVE WHOLE HOUSE VENTILATORS LEAVE THIS MANUAL WITH HOMEOWNER IMPORTANT SAFETY INSTRUCTIONS 1. Do not use this fan with any Solid-State Speed Control

More information

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg. The Extraordinaire Orbital Fan WARNING: Support Directly From Building Structure Net Weight 14.5 lbs. or 6.59 kg. Model No. OF110** OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Important Safety Instructions

More information

OPERATIONS MAINTENANCE MANUAL

OPERATIONS MAINTENANCE MANUAL OPERATIONS MAINTENANCE MANUAL COOK & HOLD OVEN SYSTEMS WITTCO MODEL NUMBERS 1300-AD-SS 1300-AD-SS-SPLIT LIMITED WARRANTY Wittco warrants the Products that it manufactures to be free from defects in materials

More information

TJERNLUND PRODUCTS, INC.

TJERNLUND PRODUCTS, INC. TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com PRESSURE SWITCH AND INSTALLATION WITH

More information

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Steam Humidifier Fan Pack Installation & Maintenance Instructions 850 Steam Humidifier Fan Pack 5658 Fan Pack Service Part Steam Humidifier Fan Pack Installation & Maintenance Instructions TABLE OF CONTENTS Safety Cautions...2 Materials List...3 Operation...3 Specifications

More information

55-Gallon Dispenser Package

55-Gallon Dispenser Package INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon Dispenser Package 08666 Rev.C INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 100 psi(6.9 bar) Maximum Air

More information

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS O P E R A T I O N S M A I N T E N A N C E MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS 1826-4 1826-7-BC-IS 1826-7 1826-13-BC-IS 1826-7-BC 1826-15-BC-IS 1826-13-BC 1826-15-BC 1826-40-BC

More information