General instructions for installation and use of Chazelles HP inserts

Size: px
Start display at page:

Download "General instructions for installation and use of Chazelles HP inserts"

Transcription

1 General instructions for installation and use of Chazelles HP inserts Route de Marthon CHAZELLES These instructions contain 23 pages numbered from 1 to 23. The contents should be read and followed for installation and, above all, for use of the appliance. Cheminées de Chazelles reserves the right to modify installation and use instructions for installation and use at any time. Diagrams and images are not contractual. Cheminées de Chazelles reserves the right to modify or delete them in order to improve understanding.

2 RANGE OF INSERTS HP HP530 HP700 HP800 2

3 1) Warning 4 2) General points Flue General points Dimensioning Flue cross-section Layout Bricked flue Metal flue Flue discharge end Stack outlet on roofing Stack outlet on terrace Crossing through floors Flue covering Occupied or habitable areas Non-habitable or inaccessible areas Crossing through roofing General points 2.2 Safety distance General points Concrete or terracotta bricked flue Metal composite flue 2.3 Fireplace surround General points Flooring Surround walls Incombustible surrounds Combustible surrounds The ceiling 2.4 Combustion air supply General points Dimensioning Air supply intake Air inlet flow Discharge end of combustion air inlet Dimensioning Air supply intake Air inlet flow Discharge end of combustion air inlet 3) Implementation Setting up the worksite 3.2 Laying out the underbase 3.3 Installation of the underbase 3.4 Combustion air inlets for Chazelles Design inserts 3.5 Installation of a Chazelles Design insert General points Specific instructions for installation Installation of the baffle (depending on version of product) Checking the automatic air-flap Installation of hood shutter kit (depending on version of product) Checking the mechanism and operation of the primary air damper Installation of the fairing kit (OPTION) Assembly 3.6 Installing the jambs and corbels 3.7 Insulation of the surround Incombustible surrounds Combustible surrounds 4 Connecting duct General points 4.2 Variation of cross-section 4.3 Direction change 4.4 Junction of connecting duct and appliance 4.5 Junction of flue and connecting duct Insulated metal flue Concrete or terracotta bricked flue 4.6 Warm air distribution 5) Installation and insulation of the wooden beam and construction of the hood Wooden beam 5.2 Construction of the hood General points Special precautions Upper and lower ventilation Lower ventilation Higher ventilation Hood false ceiling 6) Users instructions General points 6.2 Recommended fuels 6.3 Prohibited fuels 6.4 Instructions for use First lightings Lighting Continuous and intermittent operation 6.5 Restarting the fire 6.6 Controls (depending on version of product) 6.7 Maintenance Removing ashes Cleaning the window Cleaning the air guide Cleaning brass End-of-season cleaning Sweeping 7) Safety Rules General points 7.2 Chimney fires 7.3 After-sales service 8) Contractual Guarantee Duration 8.2 Legal guarantee 8.3 Validity 8.4 Exclusion Wear parts Window General points 3

4 1) Warning Set-up of a fireplace equipped with a Chazelles insert must be carried out in compliance with the regulations in force and with all documents supplied with the appliance. The instructions apply only to construction of a fireplace equipped with an insert using firewood as fuel in a private house. All national and local regulations as well as European standards must be complied with when installing and using the appliance. IMPORTANT: Checks to be carried out before setting up a fireplace equipped with an insert. Before installing the fireplace, its immediate surroundings must be checked, to ensure in particular that: - the flue to be used for evacuation of combustion products is suitable for and compatible with the appliance s design features, - the clearance from combustible materials is complied with, - the characteristics of materials making up the surfaces of your fireplace s surround comply with regulations in force and/or are compatible with the manufacturer s recommendations, - the combustion air supply duct required for the appliance s proper operation exists and is of suitable dimensions, - the mechanical resistance of the floor is sufficient to bear the weight of the fireplace equipped with the insert. 2) General points 2.1 Flue General points Flues must be in compliance with the 1969 directive, and with the rules regarding NF DTU 24.1 of February An insert can only be linked to an individual flue. The flue must enable retrieval of soot and must be able to be swept. No warm air duct must pass through a flue. All flues, tubular or lined, must bear a descriptive plate made from durable material put in by the installer, featuring its name and information on its design features. The plate may be positioned in the attic or, if necessary, on the stack. Each flue designation parameter corresponds to a designation parameter of components to be selected. T xxx: class of smoke temperature + 50 C N1: airtightness, or even N2 for bricked flues D / W: dry or wet condensation V3: corrosion G: resistant to chimney fires XXX: safety distance 4

5 2.1.2 Dimensioning The flue must be dimensioned in compliance with the EN standard, using: - the abacuses issued by the CSTB, - or calculation software - or manufacturer s instructions, if necessary Flue cross-section The inside cross-section must be constant and of the same shape throughout the height of the flue. The cross-section of the evacuation flue must be adapted to the appliance s power Layout Bricked flue The bricked flue attached must not include more than two changes in direction, i.e. more than one non-vertical part. The angle of direction change is normally restricted to Metal flue An insulated metal flue must not include more than two changes in direction, i.e. more than one non-vertical part. The angle of direction change is restricted to 45. The height between the two direction changes is restricted to five metres Flue discharge end Stack outlet on roofing The stack outlet must be located 0.4 metres above any part of the building less than eight metres distant Stack outlet on terrace In the case of a terrace roof or roof with a slope less than 15, the discharge end must be located at least 1.2 metres from the outlet on the roof covering and 1 metre above the acroterion if this latter is more than 0.2 metres. Note: Flues are not designed as fixing points for aerals, satellite dishes, or any apparatus upon which wind action might destabilise the flue Crossing through floors In all cases, it is necessary to remove any combustible materials or materials liable to degradation under the action of temperature located at ceiling level in the fireplace area. In the case of bricked flues, their crossing through the ceiling above the hood must be carried out in such a way as to ensure airtightness (shaft, firestop plate, etc.). In the case of metal flues, their crossing of the ceiling above the hood must be carried out using the safety-distance plate supplied by the flue manufacturer. No join must be located within the floor structure. The whole outside section of the first part of the flue must emerge in the room in which the fireplace is located. For the safety distance to be complied with for bricked flues, see 2.2 For the safety distance to be complied with for metal flues, see 2.2 5

6 2.1.7 Flue covering Occupied or habitable areas The surface temperature of the outside facing of the flue must not exceed 50 C in habitable areas. If it does, the flue must either be protected by an insulating covering or concealed in boxing or a shaft in order to ensure a maximum surface temperature of 50 C Non-habitable or inaccessible areas The surface temperature of the outside facing of the flue must not exceed 80 C in non-habitable or inaccessible areas. If it does this, the flue must either be protected by an insulating covering or concealed in boxing or a shaft in order to ensure a maximum surface temperature of 80 C Crossing through roofing General points The safety distance must be complied with when crossing through the roof frame. For the safety distance to be complied with in the case of bricked flues, see table in paragraph For the safety distance to be complied with in the case of metal flues, see table in paragraph Safety distance General points The element s safety distance must be greater than that stated by the manufacturer for its anticipated operating temperature, and the minimums in the NF DTU 24.1 standard. When the distance stated by the manufacturer is different from that featured in the tables below, the flue must be installed at the greater of the two values Concrete or terracotta bricked flue b r ic k e d flu e s f lu e t e m p e r a t u r e c la s s ( e le m e n t ) Metal composite flue S t a n d a r d is e d R u in m 2.K /W > to > to < T? c m 2 c m 2 c m < T c m 2 c m 2 c m T > a n d /o r re s is ta n t to c h im n e y fir e Te m pe ra ture cla sse s of co m po si te m e ta l flu e 1 0 c m 5 c m 2 c m Ther m al res ist anc e o f c om posi te m et al fl ue (R ex p res s e d in m 2. K/ W ) R < < R < 0.6 R > 0. 6 T 300 to T4 6 0 a 8 c m 5 c m a us e prohi bi ted b ec aus e of m ajor ris ks : fire and b ur ns 6

7 2.3 Fireplace surround General points All combustible materials must be removed from the fireplace surround Flooring The floor must have adequate weight-bearing capacity at the spot selected for the fireplace. It must be flat and incombustible. If this is not the case as with parquet, for instance it must be removed and a footing created of concrete, for example. The footing surface area must be at least equal to the floor space taken up by the fireplace. Thermal insulation Ventilated air space Surround walls Surround walls must contain no combustible materials and be resistant enough to bear any anchorage points necessary to the element. If they are not, the surround walls must be reconstituted using an incombustible or A2-s1, d0 (M0) material Incombustible surrounds Surrounds must be protected using material with a minimum thermal resistance of 0.7 m 2.K/W at 50 C (or of 0.4 m 2.K/W at 200 C) classed as A1 or at least M0 or A2-s1, d0 (equivalent to 30 mm of fibrous insulator of a density less than 100 kg/m 3 with aluminium foil or selfsupporting high-temperature structural insulators made of calcium silicate). Protection of an incombustible surround using a thermal insulator classed A1 or at least A2 s1 d Combustible surrounds If the surround is composed of combustible materials or materials suffering degradation under the action of heat and such materials are not removed, a new incombustible compartment must be interposed, protected in ways comparable to those mentioned in paragraph above The ceiling All combustible materials (wainscoting, for example) must be removed and replaced by an incombustible product (such as cellular concrete or roughcast bricks). 7

8 2.4 Combustion air supply General points Operation of a fireplace equipped with an insert requires a supply of air over and above that necessary to renewal of regulation air in the premises. The required cross-section may be obtained by one or more combustion air inlets..example of combustion air inlet direct connection with the appliance.(ø 100mm) Example of combustion air inlet discharging directly in the fireplace underbase Dimensioning The combustion air inlet must have a cross-section of at least 200 cm 2, unless stated otherwise by the manufacturer Air supply intake The air supply intake must be positioned: - either directly outside, in which case it is strongly advised that the fresh air supply intake is situated on a facade exposed to prevailing winds. - or in a spot ventilated from the outside or in a ventilated crawlspace, in which case it should be ascertained that the area through which air passes is not polluted (by exhaust gas, for instance). It must be protected by a grille and easily disassemblable to allow for regular cleaning. Grille mesh should be greater than 3 mm Air inlet flow If the combustion air supply crosses through an outside wall with a lining, the crossing must be airtight Discharge end of combustion air inlet The concrete slab must be absolutely open to connect the air supply unit. The discharge end of the combustion air inlet must be positioned either directly in the fireplace or near to it. It may be equipped with a closable grille when it discharges directly into the room, in order to minimise heat loss when the appliance is not actually in operation. 8

9 3) Implementation 3.1 Setting up the worksite Set out the various fireplace components near the area in which it is to be installed to identify them them using the list supplied with the appliance (technical plan). At the same time, identify (if necessary) the best-looking sides, to be sure they will be the ones visible. - Protect components as construction goes on in order to avoid dirtying. - Check dimensions, levels and squaring of each course. 3.2 Laying out the underbase When the underbase is meant to spread the weight of the fireplace on the floor, it must be designed and created with this in mind. Before starting work, it is absolutely essential to consult the plan specific to the model to be installed, which is included in the fireplace packaging. Plot out the underbase layout on the floor, as required by the flue and the surroundings. First, dry set the underbase components to check on layout and note possible drilling and shafting points. You must ensure that you comply with all necessary arrangements for the combustion air inlet. Check dimensions, levels and squarings of each course. Also check the presence of combustion air supply and passage of convection air. 3.4 Combustion air inlets for Chazelles Design inserts 3.3 Installation of the underbase Dry setting is prohibited - Seal the components using glue cement (plaster block glue, for instance). - Check surround levels and squarings. - Brick any reinforcements specified in fireplace plans with incombustible materials. - If necessary, reinforce the setting with binder covered in moulding plaster. 9 The appliance is equipped with a system enabling direct connection with the outside. If this is not used, the combustion air supply must have a cross section of at least 200cm².

10 3.5 Installation of a Chazelles Design insert General points Set-up of the insert must comply with national regulatory directives. Unauthorised modification of any kind to a Chazelles insert is prohibited Specific instructions for installation General points Various detachable parts (baffle, hearth grille, ember tray and firedog) must be removed from the appliance in order to avoid mechanical shock with the appliance window during installing the insert on its support, it is advisable to raise it using an appropriate means of lifting Installation of the baffle (depending on version of product) For maintenance and transport reasons, the baffle is detachable from the appliance. Its installation is essential to ensure the proper operation of the insert. - Insert the baffle into the appliance. - Lay the baffle on the supports designed for the purpose fitted into the decorated back. - Let the baffle rest against the supports designed for the purpose on the sides of the appliance Checking the automatic air-flap when the door is opened. When the door is opened, the automatic air-flap should tip up, freeing a section sufficient to avoid possible downdrafts due, for instance, to insufficient drawing. 10

11 Automatic air-flap control: open position. Automatic air-flap control: closed position. In all cases, it is essential that the hood ventilation air intake be ensured by the underbase or, if necessary, by the appliance s jambs or surround Checking the mechanism and operation of the primary air damper - Mechanism primary air damper The purpose of the primary air damper regulating mechanism is to regulate combustion. Its different positions act upon the output of primary air, making it possible to select fire intensity and level of power desired Installation of hood shutter kit (depending on version of product) To prevent smoke getting into the hood when opening the door following insufficient draught or forgetting to open the draught shutter, the hood shutter must be installed between the appliance and the fireplace pediment. The obturator kit comprises a galvanised metal plate and two clips to be affixed to the skirt of the appliance. Once the appliance is connected and before setting up the hood, the hood shutter must be adjusted with the fireplace pediment. Primary air damper control. Secondary air damper control. For controlling the fire, see the paragraph Instructions for use 11

12 Mechanism secondary air damper The purpose of the mechanism regulating the secondary air damper is to ensure sweeping of the window to minimise sooting up and maintain a reduced rate of combustion. Fireplace with fairing option: it must be checked that an air gap of a minimum thickness of 30 mm, if applicable cutting across the fairing with a minimum of 10 mm between the outside face of the fairing and the insulator, is made between the insulator and the appliance Installation of the fairing kit (OPTION) Assembly The fairing kit comprises the following parts: - 1 back plate - 2 sides - 1 top plate - 1 front plate - 2 collarets Ø sheet metal screws - washers Assembly must be carried out before connection to the flue. Example of an insert equipped with fairing 3.6 Installing the jambs and corbels The appliance must be placed on a stable, flat incombustible base (concrete, for example). It is important to check that a space of between 3 and 5 mm exists between the appliance s facade and the dressing, allowing for free expansion as well as providing the space necessary for air to pass (30 mm minimum) between the surround insulation and the back of the appliance. 12

13 It must be ascertained that the insulation does not obstruct combustion and convection air supplies. - Seal the components using glue cement (plaster block glue, for instance). - Check surround levels and squarings. - If necessary, reinforce the setting with binder covered in moulding plaster. - Protect components as construction goes on in order to avoid dirtying. - Check dimensions, levels and squarings of each course. The fireplace jambs, hollow or marble jambs in particular, must be protected from heat (thermal radiation) by a material with a minimum thermal resistance of 0.7m 2.K/W at 50 C (or of 0.4m 2.K/W at 200 C) classed as A1 or at least M0 or A2-s1, d0 (equivalent to 30 mm of fibrous insulator of a density less than 100 kg/m 3 with aluminium foil or self-supporting high-temperature structural insulators made of calcium silicate). 3.7 Insulation of the surround Incombustible surrounds The surround must be protected by interposition of a material with a minimum thermal resistance of 0.7m 2.K/W at 50 C (or of 0.4m 2.K/W at 200 C) classed as A1 or at least M0 or A2-s1, d0 (equivalent to 30 mm of fibrous insulator of a density less than 100 kg/m 3 with aluminium foil or self-supporting high-temperature structural insulators made of calcium silicate). 13 Example of jamb and surround insulation using 30mm panels of rock wool Combustible surrounds See paragraph Connecting duct 4.1 General points Connecting ducts for Cheminées de Chazelles inserts must be metal. Aluminium-plated steel must not be used. The diameter of the connecting duct must be at least equal to that of the appliance s pipe or sleeve. As regards flexible connecting ducts, only double-skin ducts with smooth inside walls and classed a minimum of N1 airtightness, may be used for connecting a Cheminées de Chazelles insert. The connecting duct must be able to be swept and must be dismantleable.

14 Expansion of the connecting duct, particularly at junctions, must be ensured without negatively affecting its airtightness or its mechanical performance. The connecting duct or the insulator that might surround it must be visible along the whole of its length, either directly or by means of a hatch or grille in the hood. For choice of components, refer to NFDTU 24.2 and DTU 24.1 (section 13) and to national regulations. Safety distances between connecting ducts and any combustible material must be complied with. 4.2 Variation of cross-section If the cross-section of the flue or casing, albeit adequate, differs from the cross-section of the connecting duct, reduction or increase of the cross-section can only be carried out employing a part shaped to avoid any sudden variation of cross-section. An angle of variation of cross-section less than or equal to 45 will meet this requirement. 4.3 Direction change An angle of direction change is permitted as long as it does not exceed Junction of connecting duct and appliance The connecting duct may be fitted outside on the appliance s pipe, ascertaining complete airtightness between the duct and the pipe. 4.5 Junction of flue and connecting duct Insulated metal flue The junction must be carried out on an insulated metal flue using the connecting device specially designed by the manufacturer of the insulated flue. The whole outside section of the first part of the flue must emerge in the room in which the fireplace is located. The fitting between the special device and the connecting duct must be at least 40 mm Concrete or terracotta bricked flue The junction should be carried out using the specially designed connecting device, in such a way as to ensure airtightness and good mechanical performance. The whole outside section of the first part of the flue must emerge in the room in which the fireplace is located. The fitting between the special device and the connecting duct must be at least 40 mm. 4.6 Warm air distribution Such reduction in cross-section must be located as close as possible to the hood s false ceiling. A maximum distance of 10 cm between the false ceiling and the cross-section variation is permitted. For installation of warm air distribution systems forming the subject of a Technical Evaluation, the minimum airtightness classification is defined in the Technical Evaluation. 14

15 5) Installation and insulation of the wooden beam and construction of the hood 5.1 Wooden beam All our beams are delivered with a few extra centimetres to allow for their recessing in the surround wall. Wood is a noble, living material, and consequently cracks may appear in it. When installing the decorative wooden beam, it is essential to treat it in order to prevent too rapid desiccation in warm surroundings. 5.2 Construction of the hood General points The hood is constructed in the set-up area. The obligatorily decompressed hood must be constructed of incombustible or A2-s1, d0 insulating materials. The presence of combustible materials inside the hood is prohibited. In addition, in order to avoid any major overheating that might lead to problems, a static ventilation system for the hood must be contrived, using grilles or any other efficient means of air circulation. The inside of the hood must be visible to enable checking of the connecting duct or the insulating material that might surround it Special precautions Before constructing the hood, the following precautions must be taken: - Check whether the sealing of the pediment, the beam or the metal casement can support the hood. - Check again that the appliance s moveable parts raising and opening of door and shutter, for example are working properly. - Also check that the fresh air and convection air inlets in the lower part are well dimensioned. - Check the positioning of the hood shutter (optional depending on model) Upper and lower ventilation It is important to protect the beam, either with an incombustible or minimum A2-s1, d0 insulating material, or by a baffle or pediment Lower ventilation Cross-sections for convection air inlets are defined in the product s technical card. 15

16 Higher ventilation Cross-sections for convection air outlets are defined in the product s technical card. If a warm air output grille is used, its upper part must be located as high up as possible, but at least 30 cm from the ceiling surface (or the room s false ceiling) Hood false ceiling A false ceiling for the hood must be constructed 30 cm from the ceiling. - It must be thermally insulated in the same way as the hood ceiling. - It must be ventilated by any sufficiently efficient system. NOTE 1: two openings with minimum free cross-sections of 20 cm 2 will meet this requirement. 6) Users instructions All national and local regulations and European standards must be complied with when using the appliance. 6.1 General points Cheminées de Chazelles inserts are designed to operate using firewood logs only. Maximum log length for the range of appliances is around 50 centimetres, except for CV600 and C600 inserts, for which maximum length is around 33 centimetres. It is formally prohibited to put any other type of material than firewood into the appliance. 6.2 Recommended fuels Broad-leafed hardwoods such as hornbeam, oak, beech and elm provide the best firewood. We advise you to use very dry wood (20% dampness maximum), with 2 years covered storage after cutting, in order to obtain the best results and avoid rapid bistrage of the flue and window We strongly advise you to comply with the specifications per product reference in order to ensure your product a maximum lifespan. We strongly advise you against using resinous woods (pine, fir, spruce, etc.). 6.3 Prohibited fuels All fuels other than wood are prohibited, coal and its by-products in particular. Burning straw, cardboard and liquid fuels is dangerous and to be avoided. 6.4 Instructions for use First lightings Although your fireplace may appear to have dried out fully, it is essential to wait a good three weeks between completing its installation and the first lighting, to be sure that all its constituent materials are completely dry. Don t make too strong a fire! The first lighting should be moderate and should not burn for more than three hours. During first lightings, solvents in the paintwork may give off unpleasant smells. Ventilate the room! 16

17 6.4.2 Lighting - Depending on appliance model, place screwed up paper and slivers of very dry wood on the grille or hearth, then pieces of split wood of wider diameter (3 to 5 cm). - Check that the draught damper is in open position. - Check that the draught shutter is in open position - When the load of wood slivers is well alight, open the door, load the appliance with the recommended fuel, and work the controls until you obtain the desired power Continuous and intermittent operation Global warming is a concern for preoccupies us all and, with respect for the environment in mind, we advise intermittent operation of the appliance. Controlling the fire: - The desired brightness is obtained by working the controls and selecting a load in line with your needs: For maximum heating, load the appliance with 3 logs with diameters around 12 cm. - Check that the moveable grate is pushed back to the bottom of the appliance. Use the pick (accessory supplied) to slide the moveable grate Primary air damper in position 3 and draught shutter fully open. Only use this brightness temporarily, to raise the temperature of the premises after prolonged absence. For less intense heating, use a lesser load one or two logs.. - Check that the primary air supply grille is open - Set light to the paper and put the door to (leave it slightly ajar to accelerate kindling). 17

18 Primary air damper in mid position and secondary air damper in mid position. Manipulating the moveable grate. For long-period heating, with low brightness use one or two unsplit logs with diameters greater than 15 cm (position 1) on a bed of almost dead embers. 6.5 Restarting the fire - For rapid lighting, restart the fire using wood slivers: load the appliance, leaving the door slightly ajar for a few minutes if you wish to speed up the procedure, and keeping a watch on things; then reclose the door and work the controls. This helps to speed up restarting, especially when the wood is damp. Primary air register in position 1 and draught shutter closed and adjust the secondary air damper according to drawing conditions. Work the moveable grate to remove ash and facilitate renewed combustion. - Make changes in brightness (from low to normal, for example) before reloading, while embers are burning, to allow the appliance and the flue to modify operation progressively. - To avoid smoke and ash falls in the room during reloading, the following precautions should be taken when opening the door: - Open the draught shutter, depending on models and options! - Open the door very slightly, pause to allow for draught to get going, and then slowly open the door. Manipulating the moveable grate. Continuous operation at low brightness, especially during periods of mild weather (unfavourable draught) and using damp wood, leads to incomplete combustion, which helps to cause deposits of bistrage and tar. 18

19 - Alternate periods of slow burning with returns to normal brightness. - Use small loads by preference. Pick for HP fireplace moveable grate. For manipulating the moveable grate. 6.6 Controls (depending on version of product) Accessories are at your disposal use them to avoid getting burnt! The cool hand : necessary for opening the door and setting the dampers. Glove (supplied) The scraper (supplied depending on model): for removing ashes and cleaning the appliance. 6.7 Maintenance Removing ashes The air required for combustion of wood arrives beneath the grille when the primary air damper is open, and also keeps the grille cool. In order to obtain optimal performance and avoid degradation of the grille due to overheating, it is therefore essential to prevent its obstruction by regularly removing ashes. - Use the scraper to remove ash from the grille. - Empty the contents of the ash box into a metal or non-inflammable container reserved exclusively for the purpose. Although ashes may appear cold, they can remain very hot even after cooling for some time Cleaning the window - Wait until the appliance is cool or cold before carrying out the operation. - Protect the flooring under the door to prevent dirtying it. - Clean the glass with a damp cloth. 19

20 - Spray the window with a cleaning product designed for the purpose (ask your retailer for advise), complying with the instructions on the label. - Wipe with a damp sponge Cleaning the air guide Certain models of the appliance are equipped with an air guide. In order to maintain good performance, it is important to clean this regularly in order to leave the window ventilation air gap free. To do so, wait for the window to cool down and scrape the inner edge of the air guide with one end of a metal instrument. With a vacuum cleaner, remove the dust caught between the inner edge at the top and bottom of the door and the glass Cleaning brass Depending on (optional) finishes, some appliances are equipped with a brass-covered door. Brass should be cleaned with a soft cloth and an appropriate product (ask your retailer for advice) End-of-season cleaning Thorough cleaning of the appliance, the connecting duct and the flue is recommended at the end of the season. Some models are equipped with a draught shutter which must be removed if it is detachable! (for reinsertion of baffle and draught shutter, carry out steps for removal in reverse order). - Thoroughly check the state of the appliance, elements ensuring airtightness in particular: joints and closing mechanisms, etc. - Clean the appliance with a brush and a vacuum cleaner. If there is a problem, have the appliance or installation repaired by a professional. 7) Safety Rules 7.1 General points - Never try to put out a fire by throwing water on it. - The window and certain other parts of the appliance get very hot. Watch out for risk of getting burnt especially as far as children are concerned. The fireplace radiates a lot of heat through the window glass. Do not place any heat-sensitive materials or objects closer than 1.20 metres from the glass Sweeping Mechanical sweeping of the flue is essential. It should be carried out at least twice a year, with at least one sweeping during the heating season. A certificate should be issued by the contractor after completion of the operation. Take care to remove the baffle (raise it, move it forward, lower it and take it out). Do not place any easily inflammable materials near the appliance. 20

21 Never operate the appliance without the ash box in position. - When removing ashes, empty the ash box into a metal or noninflammable container reserved exclusively for the purpose. 7.2 Chimney fires - If a chimney fire breaks out, set the primary air damper to position 1. Leave the door closed! - Remove any easily inflammable materials from the neighbourhood of the appliance. - Call the fire brigade and leave the premises. - Keep a watch on events outside (sparks from the chimneystack, for example). How do you avoid chimney fires? Chimney fires can very often be avoided simply by using dry wood! Damp wood does not only diminish calorific power, it burns poorly (bistrage of the window) and generates creosotes (tarring of the flue), which are highly inflammable! Never reuse the appliance after a chimney fire without assessment by a qualified professional, who must check damage to the flue, etc. Mechanical sweeping of the flue is essential. It should be carried out at least twice a year, with at least one sweeping during the heating season. A certificate should be issued by the sweeping company after completion of the operation. Following a long period on non-use, check that flues are unobstructed (insect nests for example) before relighting. 7.3 After-sales service We recommend that you only use replacement parts supplied by Cheminées de Chazelles 21

22 8) Contractual Guarantee 8.1 Duration The guarantee period is 10 years, for all parts manufactured by ourselves with the exception of wear parts, as from the date of delivery by the installer or the sales outlet. It applies throughout this period to all material or manufacturing defects. We shall only undertake to replace, free of charge, parts recognised as defective after verification by ourselves. 8.2 Legal guarantee The provisions of the guarantee are not excluded from the purchaser s use of the equipment covered by the legal guarantee for hidden faults and defects, which applies in all circumstances under the conditions of Articles 1641 and following of French Civil Law. 8.3 Validity The purchaser designated overleaf acknowledges having received installation instructions and agrees to comply with them. The guarantee is only valid if the appliance is used in compliance with recommendations set out in the instructions supplied with the appliance. 8.4 Exclusion Wear parts The door and window joints, hearth and decorated back, the baffle, the automatic air-flap are wear parts and are therefore guaranteed for one year as from the date of delivery of the appliance Window and refractory elements Vitroceramic windows and the refractory elements are excluded from the guarantee General points Travelling expenses, transport, labour, packaging and dismantling costs, as well as the consequences of non-use of the appliance, resulting from operations under the guarantee, shall be borne by the customer. Any malfunction of the appliance brought about by mechanical or electrical components not supplied by us and which are prohibited in the documents regarding the heating appliances, is excluded from the guarantee. Damage caused by use of any fuel other than wood. The guarantee does not apply in the following cases, (this is not an exhaustive list): but not in these alone: installation and assembly of appliances for which Cheminées de Chazelles is not responsible. Consequently, Cheminées de Chazelles cannot be held responsible for material damage or accidents to individuals following from installation not complying with legal and regulatory provisions, such as normal wear and tear of the equipment or its abnormal use, in particular in cases of use of the equipment in conditions different from those for which it was designed; it is formally prohibited to modify, transform or attempt to service the appliance. 22

23 GUARANTEE CERTIFICATE The purchaser designated hereunder acknowledges his/her awareness of the various informational documents on use and maintenance to ensure proper operation of the appliance PURCHASER Date: Surname: First name(s): Address:... Town: Country: Signature: VENDOR: document to be returned within the month following purchase at the sales outlet for the appliance Reference: Designation of appliance:.. Surname:. First names(s): Address:. :. Town: Country: Vendor s signature and stamp: 23

General instructions for installation and use of Chazelles Solo inserts

General instructions for installation and use of Chazelles Solo inserts General instructions for installation and use of Chazelles Solo inserts Route de Marthon 16380 CHAZELLES +33 5.45.23.50.50 +33 5.45.23.53.09 www.chazelles.com 1 These instructions contain 21 pages numbered

More information

General instructions for installation and use of CH700 C / CH860 C boiler inserts

General instructions for installation and use of CH700 C / CH860 C boiler inserts General instructions for installation and use of CH700 C / CH860 C boiler inserts Route de Marthon 16380 CHAZELLES +33 5.45.23.50.50 +33 5.45.23.53.09 www.chazelles.com These instructions contain 41 pages

More information

General instructions for the Installation and use of wood-burning stoves

General instructions for the Installation and use of wood-burning stoves NOTICE General instructions for the Installation and use of wood-burning stoves CONFORMING TO THE EUROPEAN STANDARD EN13240 All our appliances conform to the standards in force and meet the safety requirements.

More information

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209 TECHNICAL MANUAL Multifuel Stove Model EW1MF To be retained by the user for future reference Serial Number. Document EW1MF 0209 Thank you for purchasing an ACR Heat Products stove. The Earlswood stove

More information

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE Carbel models: C-60 Plus C-70 Plus C-80 Plus C-100 Plus C-70 Plus Double-sided C-80 Plus Double-sided C-100 Plus Double-sided CARBEL C/ Ciudad de Cartagena,

More information

Wood-burning boiler CBB. User Guide E

Wood-burning boiler CBB. User Guide E EN Wood-burning boiler User Guide 300008541-001-E . Contents 1 Symbols used...........................................................................3 2 Important recommendations...............................................................3

More information

OPERATING INSTRUCTIONS. "CLASSIC" Range

OPERATING INSTRUCTIONS. CLASSIC Range 12/2017 OPERATING INSTRUCTIONS "CLASSIC" Range www.totemfire.com Contents 1 Foreword... 2 2 Operating instructions... 2 2.1 Basic safety rules... 2 2.1.1 General points... 2 2.1.2 Fire hazard zone... 2

More information

USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS

USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS D F:\Home\RD\ME\FUNNY\FUNNYGB.WP IN-FIRE Jubilee USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS 07DHIFFUA 03/99-1 - Dear Customer! Congratulations on the purchase of your new Bodart & Gonay

More information

Page 1. Cube Ref:

Page 1. Cube Ref: Page 1 Cube Ref: 388117 Linedrawing: Technical characteristics: Unit dimensions (cm) Fire box dimensions (cm) Flue Diameter Flue outlet Recommended fuel Log size loading from the front: Panoramic glass

More information

INSTRUCTION. for installation and operation of solid fuel fireplace

INSTRUCTION. for installation and operation of solid fuel fireplace INSTRUCTION for installation and operation of solid fuel fireplace SKLADOVA TEHNIKA Division Bitova tehnika 2 Ivan Momchilov St. 5100 Gorna Oryahovitsa CONTENTS 1.Introduction...3 2.Assembling of the fireplace...3

More information

Operating and installation instructions for Fire Lotus H586

Operating and installation instructions for Fire Lotus H586 Operating and installation instructions for Fire Lotus H586 Version 1, 24 May 2016 Introduction Congratulations on your new Lotus Fire. We hope and believe that it will give you many hours of warmth.

More information

Troubleshooting and Maintenance: Wood Stoves

Troubleshooting and Maintenance: Wood Stoves Troubleshooting and Maintenance: Wood Stoves What product should I use to clean the glass? There exist many specialized products on the market. The majority works very well. They are usually sold at both

More information

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095 Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095 Before commencing with the installation it is important that these instructions are read and fully understood. The DOVRE 700CBW is

More information

MODEL SORDO SORDO SORDO SORDO 80 Flatline

MODEL SORDO SORDO SORDO SORDO 80 Flatline GEBRUIKSAANWIJZING MODE D EMPLOI OPERATING INSTRUCTIONS WARMTE RECUPERATOR TYPE INSERT RECUPERATEUR DE CHALEUR TYPE INSERT HEATING APPLIANCE INSERT TYPE MODEL SORDO 60 475.6311.100 SORDO 70 475.7311.100

More information

1. Contents Principle General information Parts list Assembly Technical drawing... 18

1. Contents Principle General information Parts list Assembly Technical drawing... 18 1. Contents 1. Contents... 2. Principle... 2 3. General information... 3-7 4. Parts list... 8 5. Assembly... 9-17 6. Technical drawing... 18 2. Principle All instructions provided with products must be

More information

Instruction Manual: Le Jurassien Ref 3701

Instruction Manual: Le Jurassien Ref 3701 General Characteristics: Overall dimensions: H 710mm x W 772mm x D 462mm Firebox: H 270mm x W 400mm x D 200mm Rear flue outlet diameter: 125mm Distance between floor and top of rear flue outlet: 530mm

More information

SAVOY MK2 Model : Technical manual STAUB FONDERIE

SAVOY MK2 Model : Technical manual STAUB FONDERIE SAVOY MK2 Document n 1274-1 ~ 03/10/2008 Multifuel stove Model : 134 08 09 Output (wood) : 8 kw Output (coal) : 7 kw Technical manual to be saved by the user for future reference STAUB FONDERIE Description

More information

Camargue. Model : Technical manual. Output : 10 kw. to be saved. by the user. for future reference. Wood stove NF EN 13240

Camargue. Model : Technical manual. Output : 10 kw. to be saved. by the user. for future reference. Wood stove NF EN 13240 Camargue Document n 1141-2~17/11/03 FR NL EN Wood stove NF EN 13240 Model : 134 10 15 Output : 10 kw Technical manual to be saved by the user for future reference Description of the appliance Installation

More information

GENERAL RULES. Ensure that the installation of your product conforms to all the indications given below. English CHIMNEY STACK

GENERAL RULES. Ensure that the installation of your product conforms to all the indications given below. English CHIMNEY STACK 1.0 GENERAL RULES DT2010216-05 Ensure that the installation of your product conforms to all the indications given below. Fig. 1 CHIMNEY STACK SINGLE FLUEWAY OR CHIMNEY CONNECTION TO FLUE SOOT INSPECTION

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo INSTALLATION, OPERATION AND MAINTENANCE Ariterm Vedo CONTENTS General...3 Installation...4-5 Laddomat 21 Connection diagram...6 Temperature control valve...7 About burning wood...8 Operation...9-11 Service

More information

General instructions for the Installation and use of hearths and inserts

General instructions for the Installation and use of hearths and inserts NOTICE General instructions for the Installation and use of hearths and inserts CONFORMING TO THE EUROPEAN STANDARD EN13229 All our appliances conform to the standards in force and meet the safety requirements.

More information

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions Fireplace inserts Model SK1000, SK2000 Installation instructions Care and firing instructions CONTENTS CONTENTS...2 GENERAL INFORMATION...3 IMPORTANT POINTS...3 PRECONDITIONS...4 Building notice Flue Combustion

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

03/2013. a t o t a l v i e w o f f i r e OPERATING INSTRUCTIONS. "technika" Range 4 FACES SUSPENDU.

03/2013. a t o t a l v i e w o f f i r e OPERATING INSTRUCTIONS. technika Range 4 FACES SUSPENDU. 03/2013 a t o t a l v i e w o f f i r e OPERATING INSTRUCTIONS "technika" Range 4 FACES SUSPENDU www.totemfire.com Contents 1 Foreword... 3 2 Operating instructions... 4 2.1 Basic safety rules... 4 2.1.1

More information

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL CE EN13240 ENJOY YOUR STOVE SAFELY Multifuel Cast Iron Stove INSTRUCTION MANUAL Congratulations on your purchase of this quality LILYKING stove. We guarantees the quality of its product and is committed

More information

ULC-S610-M87 (A1998), UL

ULC-S610-M87 (A1998), UL Gyrofocus Design Installation & Operating Manual v.6.1 EN Tested by OMNI-Test Laboratories, Inc. and approved to ULC-S610-M87 (A1998), UL 737-1996 And ULC S627-00 US EPA exempt this document was packed

More information

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference TECHNICAL MANUAL The Buxton Multifuel Stove Model BX1MF To be retained by the user for future reference Serial Number. Document BX1MF 0101 Version 1Date 17/10/2013 Thank you for purchasing an ACR Heat

More information

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE Carbel models: KRONOS 100 KRONOS 80 KRONOS 70 CARBEL C/ Ciudad de Cartagena, 22 46988 Polígono Industrial Fuente de Jarro (Paterna) Valencia Tel. 96 1340716

More information

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE 29-10-2013 CAUTION Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE Service the stove COMPLETELY as described in this manual. Check the chimney pipe. BLOCKED FLUE MESSAGE

More information

March 9th, 2009 Reviewed MYSTERE wood burning stove 490, rue de l'argon Québec (Québec) G2N 2C9 Phone: Fax :

March 9th, 2009 Reviewed MYSTERE wood burning stove 490, rue de l'argon Québec (Québec) G2N 2C9 Phone: Fax : March 9th, 2009 Reviewed MYSTERE wood burning stove 490, rue de l'argon Québec (Québec) G2N 2C9 Phone: 418-849-8095 Fax : 418-849-0077 www.jaroby.com CAN/ULC S627-M00 1 CONTENTS WARNING... 4 NOTICE...

More information

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference TECHNICAL MANUAL Malvern Multifuel Stove Model MV1MF To be retained by the user for future reference Serial Number. Document MV1MF 0101 Version 1 Date 29/04/14 Thank you for purchasing an ACR Heat Products

More information

Installation of a Brunner fireplace. General Indications

Installation of a Brunner fireplace. General Indications Installation of a Brunner fireplace General Indications CONTENTS 1 Basic informations...3 2 Safety precautions...4 3 Combustion air...5 4 Requirements for location... 6 5 Overview of fire safety and heat

More information

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT Oxford 5 Operation and Installation Manual Version A 21/06/201 (MZSOX5SMB) PLEASE ENSURE THIS MANUAL IS LEFT WITH THE HOME OWNER FOR FUTURE REFERENCE IMPORTANT It is important that this manual is read

More information

LIMOUSIN. Multifuel stove. Model : DIN EN : Output : 10 kw. Technical manual to be saved by the user for future reference

LIMOUSIN. Multifuel stove. Model : DIN EN : Output : 10 kw. Technical manual to be saved by the user for future reference LIMOUSIN Document n 1054-9 ~ 20/06/2007 Multifuel stove Model : 134 10 12 Output : 10 kw DIN EN 13240 : 2005-10 Technical manual to be saved by the user for future reference STAUB FONDERIE Description

More information

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H 1. 2. 3. 4. 5. 6. 7. Fire box door Ash pan door Air inlet control Fuel drawer Side flue gas connector Oven door with double glass Protective cover for

More information

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město LISEO Insert European Standard Certification UNE EN-13229 inserts LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město 405 02 INTRODUCTION.4 1. GUARANTEE CONDITIONS.4 1.1. SAFETY WARNINGS....4 1.2. GUARANTEE

More information

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

SAUNA HEATER INSTALLATION AND OPERATING MANUAL SAUNA HEATER INSTALLATION AND OPERATING MANUAL Type Stoveman 13 Models 13R; 13R-M; 13; 13-M; 13R-LS; 13R-M-LS; 13-M-LS; 13-LS Heating output in the sauna room 15.4 kw Sauna room cubage 6-13 m³ Fuel Wood

More information

Petit Godin 3720A, 3726, 3727, 3721A

Petit Godin 3720A, 3726, 3727, 3721A Petit Godin 3720A, 3726, 3727, 3721A This unit must be installed according to all local and national regulations in place and must conform to the technical directives contained in the user manual. The

More information

Technical Specifications Panoramic FX1

Technical Specifications Panoramic FX1 Technical Specifications Panoramic FX1 FUTURE FIRES PANORAMIC FX1 The beautifully contemporary easy on the eye Panoramic FX1 offers a fresh and innovative design, perfectly engineered for a traditional

More information

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město LISEO STOVES European Standard Certification UNE EN-13240 stoves LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město 405 02 INTRODUCTION.3 2 1. GUARANTEE CONDITIONS.3 1.1. SAFETY WARNINGS..3 1.2. GUARANTEE

More information

Scandia Avante Open Fire

Scandia Avante Open Fire Scandia Avante Open Fire Model Name Avante 900 Model Number SCOF900 Introduction Congratulations on purchasing a genuine Scandia Wood heater. When cared for properly, these high quality, finely crafted

More information

Installation, operation and care Firewood boiler Vedolux 40 UB

Installation, operation and care Firewood boiler Vedolux 40 UB Installation, operation and care Firewood boiler Vedolux 40 UB 2008-09-23 Ver 2 Replaces: 05-11 VEDOLUX 40 UB Notes 0809 To be completed when the Vedolux 40 UB is installed Serial number:... Installation

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Klapi heater 12/2017 Contents 2 1 General safety instructions 3 2 Klapi heater 4 Heater components 4 3 Technical specifications 5 Rated power, efficiency, emissions,

More information

ULC-S610-M87 (A1998), UL

ULC-S610-M87 (A1998), UL Ergofocus Design Installation & Operating Manual v.12 EN Tested by OMNI-Test Laboratories, Inc. and approved to ULC-S610-M87 (A1998), UL 737-2011 And ULC S627-00 Report Number: 304-F-04-2 US EPA exempt

More information

LIMOUSIN. Wood stove. Model : Output : 10 kw. Technical manual. to be saved. by the user. for future reference.

LIMOUSIN. Wood stove. Model : Output : 10 kw. Technical manual. to be saved. by the user. for future reference. LIMOUSIN Document n 1054-2 ~ 13/12/2000 Wood stove CGBfD-NFD35-376 Model : 134 10 12 Output : 10 kw Technical manual to be saved by the user for future reference Description of the appliance Installation

More information

INSTALLATION AND SERVICE INSTRUCTIONS. The biggest Czech producer of fi replace inserts. Accurate and precise design of details

INSTALLATION AND SERVICE INSTRUCTIONS. The biggest Czech producer of fi replace inserts. Accurate and precise design of details The biggest Czech producer of fi replace inserts Accurate and precise design of details BeF Home, s. r. o. Kotvrdovice 277 679 07 Kotvrdovice Tel.: 516/428 240 Fax: 516/428 244 IČO: 255246 The best price

More information

MONTFORT. Wood stove. Model : Technical manual to be saved by the user for future reference. Output : 5 kw FR EN NL IT EN 13240

MONTFORT. Wood stove. Model : Technical manual to be saved by the user for future reference. Output : 5 kw FR EN NL IT EN 13240 MONTFORT Document n 1171- ~ 20/02/2013 FR EN NL IT Wood stove EN 13240 Model : 134 05 01 Output : 5 kw Technical manual to be saved by the user for future reference Description of the appliance Installation

More information

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE THE NATURAL GAS MODEL IS FOR G20 AT A SUPPLY PRESSURE OF 20mbar THE PROPANE GAS MODEL IS FOR G31 AT A SUPPLY PRESSURE OF 37mbar THESE APPLIANCES

More information

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17 MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17 CE Tested by the DIN EN 13240 15a B-VG Austria Type 1 Color Emajl d.o.o. Alaginci 87 a 34000 Požega Croatia www.color.hr team@color.hr 1 Attention!

More information

LUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE. Passion for fire

LUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE. Passion for fire LUNA 850 V GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire SUMMARY 1. GENERAL REMARKS...3 2. CONNECTION...3 3. SPECIFICATION SHEET...4 4. ASSEMBLY OF THE CHIMNEY...5-7 5. ELECTRICAL CONNECTION...8

More information

Website:

Website: Operating & Installation Instructions Firebelly Production Facility: Unit 16 Upper Mills, Canalside Slaithwaite Huddersfield West Yorkshire U.K. HD7 5HA Firebelly Sales Office and Showroom: Units 6 & 7

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11 OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES F88EN-02.indd 1 04.09.2015 8:07:11 2 VKM ЕС CONTENT Introduction Use Structural designation key Delivery set Main

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide CONTENTS 1: Door Glass Blackening...Troubleshooting 1, page 3 This Troubleshooting guide is supplementary to, and must be used in conjunction with, the Instructions for Use, Installation

More information

DTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005

DTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005 DTG X.. N Low temperature gas furnace English 14/11/2005 Instructions for use Contents Important recommendations...................................................................3 1 Aeration.................................................................................................3

More information

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion AUTOMATIC MAKE-UP AIR DAMPER WITH To register this product visit: www.broan.com MODELS MD6T MD8T MD10T READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE,

More information

Monaco. model : Technical manual to be saved by the user for future reference. Output :6kW. Multifuel stove DIN EN :

Monaco. model : Technical manual to be saved by the user for future reference. Output :6kW. Multifuel stove DIN EN : Monaco Document n 1245-1 ~ 08/11/2007 Multifuel stove DIN EN 13240 : 2005-10 model : 134 06 02 Output :6kW Technical manual to be saved by the user for future reference STAUB FONDERIE Description of the

More information

Installation and Operating Manual

Installation and Operating Manual Art. No.0499132299030 V09 G22 Fireplace inserts EN13229-W Installation and Operating Manual Nameplate: Our supply program: Oil heaters Chimney stoves Pellet stoves Glazed tile and slow-burning stoves for

More information

CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS

CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS THESE INSTRUCTIONS MUST BE LEFT WITH THE USER MANUFACTURED BY: MULTIGLOW FIRES

More information

Emifocus. Design Installation & Operating Manual v.2 FR Tested by OMNI-Test Laboratories, Inc. and approved to UL and ULC-S627-00

Emifocus. Design Installation & Operating Manual v.2 FR Tested by OMNI-Test Laboratories, Inc. and approved to UL and ULC-S627-00 Emifocus Design Installation & Operating Manual v.2 FR Tested by OMNI-Test Laboratories, Inc. and approved to UL 737-2011 and ULC-S627-00 Report Number : 304-F-08-2 US EPA exempt this document was packed

More information

Installation manual Mini Comfort 50 S/L 07/ V EN

Installation manual Mini Comfort 50 S/L 07/ V EN Installation manual Mini Comfort 50 S/L 07/2015 - V 1.1 - EN www.veneco-ventilation.be Veneco ventilation by Elek Trends Productions nv Blauwfazantjesstraat 4 B - 7700 Moeskroen Tel. +32 (0)56 48 15 90

More information

Fyn Installation guide

Fyn Installation guide Fyn 450 400100929-1114 ENG Installation guide ENG 1.1 1.2 A B 1.3 1.4 1 < < < < 2.1 2.2 2.3 3.1 3.2 2 < < < < 4.1 4.2 4.3 4.4 3 < < < < Table of contents 1 Introduction... 6 2 Safety instructions... 6

More information

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only. www.windsterhood.com User s Manual UNDER CABINET SERIES RA-3030SS RA-3036SS NOTE: This unit was designed for indoor residential use and DUCTED operation only. DO NOT USE OVER A WOOD GRILL OR MOUNT OUTDOOR

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Hot Work Permits All construction sites shall implement a system of Hot Work Permits for all work activities that generate heat, sparks or flames. All of the

More information

104 MK II WOOD-BURNING STOVE

104 MK II WOOD-BURNING STOVE 104 MK II WOOD-BURNING STOVE SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR

More information

INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700,900,1100

INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700,900,1100 INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700,900,1100 English 09-2011 WARNING : THE SUPLIER TAKES NO RESPONSIBILITY FOR ANY POSSIBLE DAMAGE, POOR WORKING APPLIANCES AND ACCIDENT AS A RESULT OF INCORRECT

More information

CHIMNEYS AND VENTS CHAPTER 8

CHIMNEYS AND VENTS CHAPTER 8 CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

INSTALLATION INSTRUCTIONS USER GUIDE

INSTALLATION INSTRUCTIONS USER GUIDE INSTALLATION INSTRUCTIONS USER GUIDE Standard Rangehood HF60LX4 and HF60LW4 model NZ AU CONTENTS Safety and warnings 3 Installation instructions 5 Operating instructions 13 Cleaning and maintenance 14

More information

Decorative Fuel Effect Appliances

Decorative Fuel Effect Appliances Decorative Fuel Effect Appliances Technical Manual User and Installation Instructions for CUBB22US Available in Natural Gas. 1 Contents Section Pages 1 Unpacking 3 2 Installation Parameters 4 3 Installation

More information

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas Varde Aura Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas These instructions for fitting and operating the Smoke Control kit must be read in conjunction

More information

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For O W N E R G U I D E For VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires GB IE This Owner Guide is intended to help you care for your Valor gas fire. Please read carefully before using

More information

Furthermore, the fire flaming in your FIREPLACE hearth creates an intimate atmosphere for your family and friends.

Furthermore, the fire flaming in your FIREPLACE hearth creates an intimate atmosphere for your family and friends. Dear Customer, Thank you for your decision to buy a FIREPLACE hearth. The crackling, visible flames give you the sense of comfort and security. The combination of hot-air heating and heat radiation provides

More information

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Construction Planning All construction sites shall plan and sequence their construction activities to ensure the early installation and operation of permanent

More information

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas Varde Shape Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas These instructions for fitting and operating the Smoke Control kit must be read in conjunction

More information

TABLE OF CONTENTS: 1 INTRODUCTION

TABLE OF CONTENTS: 1 INTRODUCTION Agorafocus 630 Design Installation & Operating Manual v.3 EN Tested by OMNI-Test Laboratories, Inc. and approved to UL 737 standards Omni report number: 304-F-06-2 US EPA exempt -this document was packed

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN To respected customer, We are very pleased for your trust and your decision to buy our product. You made a good choice,

More information

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE P127003 01 P/N 127003-01 Rev. B 01/2016. HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE Read this manual carefully before using your wood burning fireplace. Understand and observe all guidelines included

More information

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE P127004 01 P/N 127004-01 Rev. B 01/2016. HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE Read this manual carefully before using your wood burning fireplace. Understand and observe all guidelines included

More information

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS AUTOMATIC MAKE-UP AIR DAMPER WITH READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Installation

More information

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS / Z / VC SERIES 2 / z / VC CONTENT Use Delivery set Structural designation key Main technical data Safety requirements Fan design Connection

More information

The Morsø S100 Series

The Morsø S100 Series The Morsø S100 Series UK Instructions for use 1-22 UK Fitting Instructions 23-49 www.morsoe.com Contents 1. Introduction...2 2. Insert types...3-12 3. Functional elements...13 4. Operations handle...13

More information

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE.

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE. DÉCOFIRE Contemporary CHIMENEA Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE. KEEP INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE

More information

Sonnet Plus Anthem Genesis Soraya

Sonnet Plus Anthem Genesis Soraya 5108617/01 OWNER GUIDE Sonnet Plus Anthem Genesis Soraya Model 746 (GC No. 32-032-57) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT

More information

^ STUV 21: MODEL SPECIFICATIONS

^ STUV 21: MODEL SPECIFICATIONS STUV 21: MODEL SPECIFICATIONS 1. PRELIMINARY INSTALL INFORMATIONS The Stuv 21 Inbuilt appliance with a four-casing flue kit was tested in a zero clearance enclosure in a manner conforming to joint Australian/New

More information

CHARNWOOD COUNTRY 6 FT

CHARNWOOD COUNTRY 6 FT CHARNWOOD COUNTRY 6 FT Operating and Installation Instructions Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K. Tel: (01983) 537799 Fax: (01983) 537788 Internet: www.charnwood.com E-Mail: charnwood@ajwells.co.uk

More information

Commissioning of Heat Producing Appliances Burning Solid Fuel

Commissioning of Heat Producing Appliances Burning Solid Fuel Building Control Technical Guidance Leaflet No. 15 This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum Commissioning of Heat Producing Appliances Burning Solid

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Twin Wall Installation Instructions And Maintenance Guide

Twin Wall Installation Instructions And Maintenance Guide Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate

More information

Rocket heater GAMERA

Rocket heater GAMERA Rocket heater GAMERA High efficiency heater on hard fuel Manufacturer: AGNON Ltd., Bulgaria Hissarya, 4 Han Kubrat STR. +359 885 525 464 WWW.GAMERA.EU ROCKETGAMERA@GMAIL.COM ATTENTION! Read the following

More information

INSET LIVE FUEL EFFECT GAS FIRE

INSET LIVE FUEL EFFECT GAS FIRE 600B741/02 OWNER S GUIDE MODEL BR650 VA (GC No. 32-032-39) INSET LIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) WHEN CONVERTED USING CONVERSION KIT NO.591149 THIS APPLIANCE

More information

Installation instruction

Installation instruction Installation instruction Ci50 www.contura.eu 82 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci50-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing

More information

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly

More information

1.0 GENERAL RULES. Ensure that the installation conforms of all the following instrucons. FLUE LOAD-BEARING CAPACITY CANNA FUMARIA FLUE

1.0 GENERAL RULES. Ensure that the installation conforms of all the following instrucons. FLUE LOAD-BEARING CAPACITY CANNA FUMARIA FLUE 1.0 GENERAL RULES DT2010844-00 Ensure that the installation conforms of all the following instrucons. Fig. 1 CHIMNEY COMIGNOLO STACK CANNA FUMARIA FLUE CONNECTION COLLEGAMENTO FLUE ALLA CANNA FUMARIA INSPECTION

More information

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+ INSTALLATION AND OPERATING INSTRUCTIONS Ariterm 60+ CONTENTS General.... 2 Installation.... 4-5 Installation of temperature limit valve... 6 Measurements and connections... 7 Technical specifications and

More information

charnwood country 4MKII Operating & Installation Instructions

charnwood country 4MKII Operating & Installation Instructions country 4MKII Operating & Installation Instructions CONTENTS OPERATING INSTRUCTIONS Fuel Fitting The Riddling Grate Lighting Controlling The Fire Refuelling Ash Clearance Low Burning Cleaning and Maintenance

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS 500 SERIES 2013 INSTALLATION & OPERATING INSTRUCTIONS Serial Number of Heater: Model: HEATCHARM WOODHEATERS ARE AUSTRALIAN OWNED AND MANUFACTURED BY SHAMIC SHEETMETAL (AUST.) PTY. LTD. PO BOX 8, KILSYTH,

More information