CGWP Small Scroll Chiller Cabinet Water Cooled Cold Generator 10~100 Tons
|
|
- Patience McKinney
- 5 years ago
- Views:
Transcription
1 CGWP Small Scroll Chiller Cabinet Water Cooled Cold Generator 10~100 Tons
2 Features and Benefits High efficiency and low running noise Multi scroll compressors design achieve high running efficiency at partial and full load of system operation. Outstanding vibration isolator design, fully enclosed by noiseabsorption jacket. At least 30% EER higher and 3~ dba noise lower than aircooled chiller at the same running environment. Design for residential and light commercial especially. Shell and tube heat exchanger condenser, reserved the refresh capability by periodic maintenance. Indepedent Operation / Service budget MultiChiller system is designed for separative cooling demand. Integrated condenser piping system and independent chilled water piping ensure the whole system in most cost effective and operating efficiency. Most of the operation and service fee can charge to individual owner directly. Compact system design and excellent appearance 1/4 volume reduction compared with existed version and competitors. Compact in footprint. Easy for lifted by elevator and install in place where space is precious. Powder painting enclosure, free of rust for longer than normal treatment. Deform free frame design and symmetric internal layout. American Standard Inc. 001 CGWPPRC001EN
3 No refrigerant piping around your living space Chiller system deliveries cooling capacity by water. With totally different design philosophy of direct expansion system like minisplit, water piping means steady, safty, healthy high efficiency, low piping layout limitation and problem free after system installation. Multi choice of indoor units (concealed/exposed/cassette) make the system complied with diversfied interior decoration need. 3 CGWPPRC001EN
4 Mechanical Specifications High Reliability Scroll compressors and durable system components arranged by Trane fully experienced chiller technology. Completely cutouts and protections from abnormal start up and operation. Double antifreeze protection. Non flammable insulation at concerned side. 100% factory inspection and running test before shipment. Manufacturing by ISO 000 qualified factory. Minimun space needed and easy for maintenance Creative top hood access panel design, constrict the maintenance space need to 60 cm around chiller. Life the top panel can reach control and wiring board for electrical investigation and maintenance. Compressor Scroll compliance allows liquid and dirt to pass through without damaging compressor. Suction gas cooled two pole motor with solidstate protection against overheat and overload. Evaporator 010~060 Compact size AISI 316 brazed heat exchanger, suction piping insulate with 1/ thickness PU. A 16mesh Y strainer (factory provided, field install) should be installed in the water inlet to prevent circuit blocked. 080~100 Seamless internal enhanced copper tube in shell design. A 4 flangle type strainer is provided and factory connection. Condenser Seamless external enhanced copper tube in shell design, refrigerant side is tested at 34.kg/cm G (00psig) and kg/cm G(3psig) for waterside. Refrigerant Circuit Each refrigerant circuit is completely independent, includes thermal expansion valve, filter dryer, sightglass, charging port, insulated suction line and pressure gauges. Control Safe, effective and reliable control system, only minimal maintenance is required. Friendly interface makes job site wiring easy and neat. Phase reversal switch, contactor, relays and overload protectors are standard buildin components. SMM Controller (option) Design and manufacture with TRANE chiller technology, Scroll Management Module (SMM) build in fully protective functions and operation orientation. Compatible with TRANE Tracer/Summit Building Automation System. Sound Attenuation PE wavy from inside panel isolation to attenuate the chiller operation sound. Top hood access panel American Standard Inc CGWPPRC001EN
5 Model Nomenclature Dimensions CGWP 010 C D R N N N A CGWP010~01 1,,3,4,6, Digit 1,,3,4 Chiller Type CGWP Watercooled Scroll Chiller Digit,6, Model (nominal cooling capacity) Digit 8 Voltage 1 0V/60Hz/1Ph Model 010 only 0V/60Hz/3Ph 3 380V/60Hz/3Ph 4 440V/60Hz/3Ph 380V/0Hz/3Ph 6 400V/0Hz/3Ph 41V/0Hz/3Ph CGWP00~030 CGWP040~060 Digit Development Sequence C Third Digit 10 Number of Compressors D Dual Compressors 010~030, circuits F Four Compressors 040~100, circuits Digit Water Connection R Right Hand Side Standard L Left Hand Side CGWP080~100 Digit 1 Control N No Standard U SMM Controller Digit 13 Future Use N No Standard Digit 14 Options N No Standard I Spring Isolator Digit 1 Design Sequence A First CGWPPRC001EN
6 Performance Data CGWP010 LPME:100 LPMC:10 60Hz 0Hz LW( C) kw Model EW( C) LW( C) kw Model EW( C) CGWP010 LPME:86 LPMC: American Standard Inc. 001 CGWPPRC001EN 6 CGWP01 LPME:10 LPMC:144 CGWP01 LPME:103 LPMC:10 CGWP01 LPME:10 LPMC:180 CGWP01 LPME:1 LPMC:10 CGWP00 LPME:00 LPMC:40 CGWP00 LPME:1 LPMC:00 CGWP0 LPME:0 LPMC:300 CGWP0 LPME:1 LPMC:0 CGWP030 LPME:300 LPMC:360 CGWP030 LPME: LPMC:300 CGWP040 LPME:400 LPMC:480 CGWP040 LPME:344 LPMC:400 CGWP00 LPME:430 LPMC:00 CGWP060 LPME:600 LPMC:0 CGWP060 LPME:14 LPMC:600 NOTE EWCondenser water inlet temperature. LWChiller water outlet temperature. LPMERated water flow rate of evaporator (LPM) LPMCRated water flow rate of condenser CGWP00 LPME:00 LPMC:600 CGWP080 LPME:800 LPMC:60 CGWP100 LPME:1000 LPMC:100 CGWP00 LPME:00 LPMC:1080 CGWP080 LPME:681 LPMC:81 CGWP00 LPME:6 LPMC:0 CGWP100 LPME:840 LPMC:1000
7 General Characteristic 60Hz Item Model (kw) Circuit Load (%) VoltPhase (kw) V1Ph60Hz V/380V/440V3Ph60Hz RLA LRA Evaporator Condenser 0V 380V 440V 0V 380V 440V Type Water Flow (LPM) WPD (m HO) Type Water Flow (LPM) WPD (m HO) Refrigerant R Charge (kg) Oil Charge (L) SUNISO 4GS Length (mm) Dimension Depth (mm) Brazed plate heat exchanger Height (mm) Operating Weight (kg) Protection Water Pipe in/out (øfpt) 1 1/ Shell and tube R./ /4.0 4./4..0/.0./../. 1.0/ / / / / / H/L pressure switches, Freezestat, Fusible plug, Overload, Adjustable temperature switch, Phase reversal switch. 1/ Shell and tube Hz Item Model (kw) Circuit Load (%) VoltPhase 380V/400V/41V3Ph0Hz (kw) RLA LRA Evaporator Condenser 380V 400V 41V 380V 400V 41V Type Water Flow (LPM) WPD (m HO) Type Water Flow (LPM) WPD (m HO) Refrigerant R Charge (kg) Oil Charge (L) SUNISO 4GS Length (mm) Dimension Depth (mm) Height (mm) Operating Weight (kg) Protection Water Pipe in/out (øfpt) 1 1/ 1/ NOTE 1. capacity rated conditions a. Chiller water inlet/outlet temperature = 1 C/ C. b. Condenser water inlet/outlet temperature = 30 C/3 C.. Tolerance of the data as above is ± % according with Standard ARI Component description : Compressor/Scroll Brazed plate heat exchanger Shell and tube R /4.0 4./4..0/.0./../../. 1.0/ / / / / / H/L pressure switches, Freezestat, Fusible plug, Overload, Adjustable temperature switch, Phase reversal switch Shell and tube CGWPPRC001EN
8 FM ISO 00 Qualified factory Trane Taiwan North American Group The Trane Company 3600 Pammel Creek Road La Crosse, Wl 4601 http : // Literature Order Number File Number Supersedes Stocking location CGWPTS4 CGWPPRC001EN003 CGWPTS3 Taipei, Taiwan An AmericanStandard Company Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.
Air-Cooled Water Chiller Air-Cooled Water Chiller with Heat Pump Option 3~30 Tons
Air-Cooled Water Chiller Air-Cooled Water Chiller with Heat Pump Option 3~30 Tons Features and Benefits Air-Cooled Water Chiller Air-Cooled Water Chiller With Heat Pump Option Appearance The KOOLMAN is
More informationCGAH 020~060 Liquid Chillers, Air Cooled, Axial Fan. Reliable, Efficient, and Quiet Operation. Reduced Maintenance. Fitted with Scroll Compressors.
CGH 00~060 Liquid Chillers, ir Cooled, xial Fan. Reliable, Efficient, and Quiet Operation. Reduced Maintenance. Fitted with Scroll Compressors. From Components to System Technology Scroll compressor has
More informationKoolman Air-Coolded Water Chiller With Heat Pump Option
Koolman Air-Coolded Water Chiller With Heat Pump Option CGAK/R 030-150 9.8~39 kw PKGP-PRC006-EN Contents Features and Benefits 4 Mechanical Specifications 5 Model Nomenclature 6 Performance Data 7 Dimensions
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationWater-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X
Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationMulti-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw
Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More informationCall us today! (800)
150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationkw COOLING kw HEATING
Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...
More informationnemo a hp rcgroupairconditioning R410A
NEMO A HP: Motoevaporating heat pumps for indoor installation, equipped with scroll compressor and plate heat exchanger Cooling Capacity: 5,5 25,0 Heating Capacity: 6,4 29,3 nemo a hp PLATE rcgroupairconditioning
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationWZH Ground source heat pumps
Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More information60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS
R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationNEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw
Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 Built-in pumping group Scroll compressor Plate type heat exchanger EER up to 2,88 rcgroup.it Chillers : Motoevaporating units
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationZeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017
Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air
More informationDate: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days
Proposal Trane A Division of American Standard Inc. Prepared For: John Weston Desmet Ballestra Job Name: LAUER1 Biodiesel Chiller Pennsylvania Date: August 21, 2006 Proposal Number: G1-95502-1 Engineer:
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationEASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB
R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL
More informationPURESTREAM CHILL-CUBE TM BY FRIULAIR
PURESTREAM CHILL-CUBE TM BY FRIULAIR Air-cooled water chiller Cooling capacity from 0.5 to 6 tons R407C Refrigerant QPS Inspection label certified to CSA standards 2 Year parts warranty The QBE Chill-Cube
More informationGUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers
GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationwater to water heat pumps
AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically
More informationLZA High efficiency air to water heat pumps with HP compressor
High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationAs a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.
NOMENCLATURE INTRODUCTION The HTT HWDX water-cooled chillers range is the latest addition to HTT s growing family of commercial products, featuring the most current technologies advances. The HWDX main
More informationSubmittal. Date: September 04, Customer P.O. Number: Customer Project Number:
Submittal Prepared For: All Bidders Sold To: Date: September 04, 2012 Customer P.O. Number: Customer Project Number: Job Number: Job Name: DCS 12473 80 Ton Chiller Dept of Wildlife 1801 N Lincoln OKLAHOMA
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationLSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES
Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationSplit System Heat Pump Product & Performance Data
SS-PRC007-EN Split System Heat Pump Product & Performance Data XL14i 2TWX4018-060 1½ 5 Tons PUB. NO. 22-1750-05 Features and Benefits Climatuff compressor Efficiency up to 15.25 SEER and 9.6 HSPF All aluminum
More informationMODELS LIST. Nominal Capacity RT
1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION
More informationAIR COOLED PACKAGED CHILLER
AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its
More informationCentral Chillers TS Series
www.thermalcare.com Central Chillers TS Series With over 40 years of process cooling experience, Thermal Care is the dependable choice for industrial process chillers. Our TS Series is just one of several
More informationLDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES
Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationWater chillers water/water type SIGMA Technical information manual
Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity
More informationAir-Cooled Modular Split Systems. Product Data Catalog
sm Air-Cooled Modular Split Systems Product Data Catalog MS010XN_A, MS015XN_A, MS020XN_A, MS030XN_A, MS040XN_A, MS050XN_A, MS070XN_A, MS085XN_A Standard and Total Access Configurations Features & Benefits
More informationPACKAGED AIR COOLED Product Data Catalog
PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES
More informationWicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1
Addendum No. 1 Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD 21801 Ph. 410-548-4805 Fax 410-334-3130 Addendum # 1 Date: 3/11/2016 Bid: Chiller Removal and Installation A Pre-Bid
More informationAir-to-water scroll chillers
Air-to-water scroll chillers Model CGA 040 to 115 Cooling capacity: 14-40 kw CG-PRC031B-GB Table of Contents Technical specifications...4 Standard configuration... 4 Hydraulic version... 4 Casing... 4
More informationSECTION AIR COOLED WATER CHILLERS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2
More informationWSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES
Water to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures
More informationEQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM
TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16
More informationDOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,
DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded
More informationSECTION ROTARY-SCREW WATER CHILLERS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More informationKELVIN Clim F497. Kelvin air conditioning
KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationAPPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)
4-1280 Application Engineering Bulletin AE-1280R4 Revised April, 1995 APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models) Introduction The Compliant Scroll Compressor has been
More informationYCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw
YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 141 kw to 360 kw YORK YCAL-SB Millennium air cooled scroll liquid chillers provide chilled liquid for all air conditioning
More informationScroll Water Cooled Chiller
Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical
More informationnemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING
171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw 172 VERSIONS
More informationNeosys Product catalogue
00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled
More informationPackaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB
Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...
More informationAQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING
Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationLZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationtons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application
6.2-30 tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application High-performance, energy-saving, cost-effective rooftop air conditioning solutions for your business
More informationProduct Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz
Product Catalogue CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to Tons Models: 50 / 60 Hz CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD CGAD July 2012 CG-PRC002E-EN Introduction IMPORTANT:
More informationTECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely
More informationScrew Water Cooled Chiller SCW210
Screw Water Cooled Chiller SCW210 Nominal Cooling Capacity 185.1 to1480.8 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical
More informationpyxis pyxisa NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning
More informationMAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.
Temperature Control Units Water & Oil 30-500 F Portable Chillers Air & Water-Cooled 20-70 F Central Chillers Air & Water-Cooled Packages & Modules 20-70 F Pump Tank Stations Chilled or Tower Water 200-3600
More informationUltimate energy saving technology
Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today
More informationAir Cooled Scroll Chiller / Heat Pump
Air Cooled Scroll Chiller / Heat Pump SRA 145 Nominal Capacity 67.5 to 1080 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data R407c 5 Physical Data R134a 6 Unit Performance
More informationMSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08
MSRW MINI SERIES Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08 Contents FEATURES 1 C1 CONTROL 4 PHYSICAL DATA 5 UNIT CAPACITY 7 CHILLER SELECTION
More informationExclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant
More informationKelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw
Cooling Capacity: 250 ~ 1240 kw Water cooled liquid chillers in A class energy efficiency for indoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded
More informationGLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationLQ AQ SQ. Air-cooled and water-cooled portable chillers
LQ AQ SQ Air-cooled and water-cooled portable chillers Choose from a complete line of dependable Accuchiller portable chillers LQ Series AQ Series SQ Series No other manufacturer can offer you a larger
More informationProduct Data. Features/Benefits. 19XB Positive Pressure Storage System
Product Data 19XB Positive Pressure Storage System 19XB028 Copyright 1992 Carrier Corporation 19XB052 Carrier s Positive Pressure Storage (PPS) System ensures the critical conservation of refrigerants
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationProduct Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C
Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationMODULAR CHILLER. R410a R22
Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model
More information