Experimental and Numerical Study of a Mobile Reversible Air Conditioning Heat Pump System Charge Imbalance when Switching Modes Paper #2569

Size: px
Start display at page:

Download "Experimental and Numerical Study of a Mobile Reversible Air Conditioning Heat Pump System Charge Imbalance when Switching Modes Paper #2569"

Transcription

1 Experimental and Numerical Study of a Mobile Reversible Air Conditioning Heat Pump System Charge Imbalance when Switching Modes Lili Feng 1 (lfeng8@illinois.edu) Pega Hrnjak 1, (pega@illinois.edu) 1 Air Conditioning and Refrigeration Center MechSE Department, University of Illinois Urbana Champaign Creative Thermal Solutions

2 Outline Background of heat pump for electric vehicles Refrigerant charge imbalance when switching modes Charge determination for A/C and HP Charge retention in components measurement Charge imbalance modeling and minimization strategies Conclusion July 11 14, 16 Purdue Conferences /16

3 Background on reversible AC/HP systems for EV PTC heating drains battery quickly and reduces drive range largely Reversible AC/HP system largely reduces battery drainage for EV cabin heating compared to PTC heater A/C components available for heating function List of current EV models using heat pump: Nissan Leaf, Renault Zoe, KIA Soul, BMW i3, VW e Golf, and growing Many different reversible system configurations has been proposed, varying from direct refrigerant to air to indirect refrigerant to coolant toair, and mixed configurations July 11 14, 16 Purdue Conferences 3/16

4 Configuration based on Nissan Leaf system July 11 14, 16 Purdue Conferences 4/16

5 Components of the experimentally studied system 587 mm 49 mm 311 mm 9 tubes 197 mm 4 passes 15/14/18/11 19 tubes Evaporator Outdoor heat exchanger 189 mm 151 mm slabs tubes EEV July 11 14, 16 Purdue Conferences Compressor Accumulator Inner Condenser 5/16

6 Charge imbalance when switching modes The system needs more charge for A/C mode than for HP mode When reheat is needed in A/C mode, system needs even more charge Effect of imbalance: large accumulator size, liquid refrigerant entering compressor suction, oil return A/C mode HP mode July 11 14, 16 Purdue Conferences 6/16

7 Charge imbalance effects Liquid storage reservoir size Using accumulator for excess liquid storage affects oil return to compressor e.g.: minimum allowed suction quality (x suc ) 95% oil circulation ratio (OCR) 5% excess refrigerant liquid stored in accumulator (m ref,liq,accu ) 1 g Assuming oil and liquid refrigerant are well mixed m oil, accu m ref, liq, accu (1 x OCR ) (1 OCR) oil mass in accumulator 15.3 g Over charge system with oil Use internal heat exchanger Store excess liquid in high side Reduce charge imbalance suc July 11 14, 16 Purdue Conferences 7/16

8 Charge imbalance breakdown in components HP mode V[cm 3 ] 5 Internal volume HP ref. mass A/C ref. mass m[g] A/C mode 5 Comp. Lines HEX's Accu HP internal volume A/C internal volume HP ref. mass A/C ref. mass HP ref. mass A/C ref. mass 3 5 V [cm3] m [g] V [cm3] m[g] Dis. Liq. ph Suc. line July 11 14, 16 Purdue Conferences I.D. cond. O.D. HX Evap. 8/16

9 Liquid line size minimization and balancing HP mode A/C mode HP liquid line in A/C mode: discharge line Balance between charge and COP A/C liquid line in HP mode: Before 3 way valve suction line Minimize length by placing 3 way valve close to outdoor heat exchanger outlet After 3 way valve bypassed Minimize diameter for not having flash evaporation July 11 14, 16 Purdue Conferences 9/16

10 Microchannel heat exchanger: finite volume/ε NTU method Break into elements along refrigerant flow List of empirical correlations Subject Correlation Assumptions: 1. Steady state flow and heat transfer;. Uniform distribution among parallel tubes; 3. Pressure drop in headers neglected; Single phase htc Gnielinski 1976 Single phase frictional pressure drop Churchill 1977 Two phase evaporation htc Kandlikar 14 Two phase condensation htc Cavallini et al 6 Condensing superheated zone htc Kondou and Hrnjak 1 Two phase frictional pressure drop Friedel 1976 (Evap) Cavallini et al 9 (Cond) Air side htc Chang and Wang 1996 Air side pressure drop Chang et al 1994 July 11 14, 16 Purdue Conferences 1 /16

11 Internal volume [cm 3 ] Microchannel heat exchanger: charge retention modeling Internal volume: headers take a large portion of the internal volume, and can retain the majority of refrigerant charge Microchannel tube charge retention: Not very sensitive to selection of void fraction correlation? May be affected by maldistribution? Header charge retention: 5 Mass flux/flow regime Gravity Protrusion Headers MC tubes I.D. Cond O.D. HX Evap July 11 14, 16 Purdue Conferences 11 /16

12 Compressor, accumulator: simplified model by fitting with data Compressor: Calculate shaft work, refrigerant mass flow rate, and discharge state from suction state, discharge pressure, and compressor speed Volumetric efficiency 1/ n poly Pdis volm 1 cv 1 Psuc Isentropic efficiency isen Pdis P Q volm Heat loss from shell loss suc a( Tdis Tamb) b( Tsuc Tamb) Accumulator: m ref Calculate suction quality or superheat based on refrigerant charge amount left in the accumulator, hll, liq Cd, pinhole Apinhole P f hll P P P P P dyn fri res dyn G f Utube L D 1 C d, res g G P Utube g G Utube g hydr P P hyd Cd, res f P gh f ll res Re D July 11 14, 16 Purdue Conferences 1 /16

13 System heating performance modeling results Good prediction of Q and HPF trends with varying working conditions ~1% over prediction of Q, primarily due to unaccounted maldistribution in outdoor heat exchanger (details can be found in paper) W[kW], Q[kW], HPF Indoor air flow rate [kg/min] N cp =146[rpm], T outdoor = C, v ohex =4 m/s, T indoor =1 C Q_heating_meas Q_heating_mdl W_shaft_meas W_shaft_mdl HPF_meas HPF_mdl 1 15 Compressor speed [RPM] T outdoor = C, v ohex =4 m/s, m indoor =6 kg/min, T indoor =1 C Outdoor air face velocity [m/s] N cp =146[rpm], T outdoor = C, m indoor =6 kg/min, T indoor =1 C W[kW], Q[kW], HPF W[kW], Q[kW], HPF July 11 14, 16 Purdue Conferences 13 /16

14 Refrigerant mass [g] Refrigerant charge retention modeling results I Model ran at the same operating conditions as experiments HP: T id = 1 [C], T od = 1 [C], mfr id = 6 [kg/min], Vel cai = 4 [m/s], SC = 6 [C], m charge = 181 [g] A/C: T id = 4 [C], T od = 4 [C], Vel eai =.5 [m/s], Vel cai = 3.7 [m/s], SC = 8.4 [C], SH = 18. [C] Indoor condenser: under prediction of charge in both HP and A/C Single phase inlet and outlet header at bottom, liquid can get trapped in inlet header Small intermediate header (~14 cm 3 ) Inlet and outlet at the same side, channels far away from inlet/outlet may get clogged by liquid refrigerant oil mixture HP measured A/C measured I.D Cond O.D. HX Evap July 11 14, 16 Purdue Conferences 7 modeled in MC tubes /16

15 Refrigerant mass [g] Refrigerant charge retention modeling results II HP measured A/C measured I.D Cond O.D. HX Evap July 11 14, 16 Purdue Conferences 7 modeled in MC tubes Outdoor heat exchanger 38 g (7%) underestimation of imbalance: Header retention model accuracy channels clogged by liquid refrigerant oil mixture In A/C mode as a condenser, most of the charge resides in nd pass and outlet header Reverse flow direction in A/C mode to reduce nd pass and outlet header size Use the extra charge in HP mode, i.e., for flash V [cm3], m [g] gas bypass internal volume HP mode 6 A/C mode I.H. 1 1st pass O.H. 1 I.H. nd pass O.H. 15 /16 5 9

16 Summary and Conclusion A mobile AC/HP system based on Nissan Leaf configuration was studied System charge imbalance when switching ~3 g in total, ~15 g caused by inappropriate liquid line sizing, ~14 g caused by outdoor heat exchanger changing role Liquid line sizing Liquid line may work as discharge line or suction line in another mode, line size should be constrained by acceptable COP/HPF and Q reduction Minimize liquid line size for acceptable subcooling decrease Outdoor heat exchanger caused ~14 g of imbalance when switching modes As a condenser, most of charge resides in the nd pass and outlet header, reversing refrigerant flow direction can help to reduce charge in A/C mode Charge retention difference can be used for flash gas bypass in HP mode, to send only liquid to outdoor heat exchanger for better heat transfer performance July 11 14, 16 Purdue Conferences 16/16

17 Lili Feng July 11 14, 16 Purdue Conferences

Designated vs Non-designated Areas for Condenser Subcooling

Designated vs Non-designated Areas for Condenser Subcooling Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Designated vs Non-designated Areas for Condenser Subcooling Gustavo Pottker

More information

Control of FGB (Flash Gas Bypass) in Start-Up and Transients. Mr. Nemanja Dzinic, Pega Hrnjak CTS, USA & MPG-KGH d.o.o., Serbia

Control of FGB (Flash Gas Bypass) in Start-Up and Transients. Mr. Nemanja Dzinic, Pega Hrnjak CTS, USA & MPG-KGH d.o.o., Serbia Control of FGB (Flash Gas Bypass) in Start-Up and Transients Mr. Nemanja Dzinic, Pega Hrnjak CTS, USA & MPG-KGH d.o.o., Serbia Background Microchannel evaporators widely used in MAC systems and increasingly

More information

Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel Heat Exchanger Using Infrared Thermography

Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel Heat Exchanger Using Infrared Thermography Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel

More information

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR Santhosh Kumar Student(M.Tech), Mechanical Dept Gokul group of institutions Visakhapatnam, India M Karteek Naidu ASST PROFF, Mechanical

More information

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Research On Gas Injection High Temperature Heat Pump With

More information

EFFECT OF OIL IN CIRCULATION ON AUTOMOTIVE A/C COMPONENT AND SYSTEM PERFORMANCE XUAN LIU THESIS

EFFECT OF OIL IN CIRCULATION ON AUTOMOTIVE A/C COMPONENT AND SYSTEM PERFORMANCE XUAN LIU THESIS 2015 Xuan Liu EFFECT OF OIL IN CIRCULATION ON AUTOMOTIVE A/C COMPONENT AND SYSTEM PERFORMANCE BY XUAN LIU THESIS Submitted in partial fulfillment of the requirements for the degree of Master of Science

More information

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS A. Hafner SINTEF Energy Research Refrigeration and Air Conditioning Trondheim (Norway) ABSTRACT The natural refrigerant carbon dioxide (CO 2 ) with all its

More information

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 216 Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration

More information

Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using Propane

Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using Propane Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using

More information

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT R. Prapainop 1* and K. O. Suen 2 1 Department of Mechanical Engineering, Kasetsart University, Si Racha Campus, Chonburi, Thailand 2 Department

More information

Effect of Condenser Subcooling of the Performance of Vapor Compression Systems: Experimental and Numerical Investigation

Effect of Condenser Subcooling of the Performance of Vapor Compression Systems: Experimental and Numerical Investigation Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Effect of Condenser Subcooling of the Performance of Vapor Compression

More information

2015 DAVID JAMES KAISER

2015 DAVID JAMES KAISER 2015 DAVID JAMES KAISER SECONDARY LOOP REVERSIBLE AC/HP SYSTEM FOR ELECTRIC VEHICLES BY DAVID JAMES KAISER THESIS Submitted in partial fulfillment of the requirements for the degree of Master of Science

More information

Investigation of Evaporator Performance with and without Liquid Overfeeding

Investigation of Evaporator Performance with and without Liquid Overfeeding Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Investigation of Evaporator Performance with and without Liquid Overfeeding

More information

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental and Numerical Study on the Performance of R410A Liquid Recirculation

More information

Refrigerant Mass and Oil Migration During Start-up Transient

Refrigerant Mass and Oil Migration During Start-up Transient Refrigerant Mass and Oil Migration During Start-up Transient Steffen Peuker, Predrag Hrnjak* Department of Mechanical and Industrial Engineering University of Illinois at Urbana-Champaign 1206 West Green

More information

Investigation of Port Level Refrigerant Flow Mal-distribution in Microchannel Heat Exchanger

Investigation of Port Level Refrigerant Flow Mal-distribution in Microchannel Heat Exchanger Investigation of Port Level Refrigerant Flow Mal-distribution in Microchannel Heat Exchanger Zhenning Li, Jiazhen Ling, Vikrant Aute, Reinhard Radermacher 12 th IEA Heat Pump Conference, 2017 Center for

More information

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor Mingyue Huang a, Xiangfei Liang a,b *, Rong Zhuang a a Gree Electric Appliances, Inc.of Zhuhai,Zhuhai 519070,China

More information

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric

More information

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Control Method Of Circulating Refrigerant Amount For Heat Pump System Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Control Method Of Circulating Refrigerant Amount For Heat Pump System Jin

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management EXPERIMENTAL AND THEORETICAL STUDY OF MINIATURE VAPOR COMPRESSION CYCLE USING MICROCHANNEL CONDENSER Issam M. Ali Aljubury*, Ahmed Q. Mohammed, Marwa S. Neama * Mechanical Eng. Dept. College of Engineering,

More information

Modeling and Design of an Indirect Air Conditioning System Operating With Low GWP Zeotropic Mixtures

Modeling and Design of an Indirect Air Conditioning System Operating With Low GWP Zeotropic Mixtures Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Modeling and Design of an Indirect Air Conditioning System Operating With

More information

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 22 An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning

More information

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

More information

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps AM-4249223-1 - Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps Christian K. Bach, Graduate Student, Eckhard A. Groll, Reilly Professor, James

More information

Comparison of Oil Retention in R134a and CO 2 Climate Control Systems

Comparison of Oil Retention in R134a and CO 2 Climate Control Systems Comparison of Oil Retention in R134a and CO 2 Climate Control Systems Lorenzo Cremaschi Yunho Hwang,Ph.D. Reinhard Radermacher, Ph.D. CEEE University of Maryland Objective: Introduction Research Overview

More information

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps

More information

Dynamic Simulation of Liquid Chillers

Dynamic Simulation of Liquid Chillers Purdue University Purdue epubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Dynamic Simulation of Liquid Chillers I. N. Grace Brunel University S. A.

More information

Performance of CO2 Cycles with a Two-Stage Compressor

Performance of CO2 Cycles with a Two-Stage Compressor Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2004 Performance of CO2 Cycles with a Two-Stage Yun Hong Hwang University of

More information

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Comparison of Performance of a Residential Air- Conditioning System Using

More information

Compendium DES July 2016, CARN

Compendium DES July 2016, CARN Compendium DES July 2016, CARN 1 Contents Contents... 2 1. Energy balance... 4 Using Energy Balance for analyzing energy systems... 4 Energy Balance definition... 4 Steady state, steady flow... 4 Methodology...

More information

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 111 CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 7.1 INTRODUCTION Energy is the primary component to run any system in the world. According to

More information

Purdue e-pubs. Purdue University

Purdue e-pubs. Purdue University Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 206 Experimental Investigation of the Refrigerant Flow Distribution Characteristic

More information

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Design Optimization of Variable Geometry Microchannel Heat Exchangers Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Design Optimization of Variable Geometry Microchannel Heat Exchangers Long

More information

Performance of an Improved Household Refrigerator/Freezer

Performance of an Improved Household Refrigerator/Freezer Performance of an Improved Household Refrigerator/Freezer D. O. Ariyo Department of Mechanical Engineering, School of Engineering, Federal Polytechnic, Offa, Nigeria Y. L. Shuaib-Babata Department of Mechanical

More information

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences - Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems

More information

Design and Optimization of Capillary Tube- Suction Line Heat Exchangers

Design and Optimization of Capillary Tube- Suction Line Heat Exchangers Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2004 Design and Optimization of Capillary Tube- Suction Line Heat Exchangers

More information

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning

More information

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM Hantz, D., Gulyas, G., Bensafi, A. Centre Technique des Industries Aéraulique et Thermique (CETIAT) BP 2042

More information

Homework Chapter2. Homework Chapter3

Homework Chapter2. Homework Chapter3 Homework Chapter2 2/1 A storage tank holds methane at 120 K, with a quality of 25 %, and it warms up by 5 C per hour due to a failure in the refrigeration system. How long time will it take before the

More information

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Effect of the Use Pattern on Performance of Heat Pump Water Heater Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering July 2018 Effect of the Use Pattern on Performance of Heat Pump Water Heater

More information

ENSC 388. Assignment #6

ENSC 388. Assignment #6 ENSC 388 Assignment #6 Assignment date: Wednesday Oct. 21, 2009 Due date: Wednesday Oct. 28, 2009 Problem 1 A turbine operating at steady state receives air at a pressure of 3.0 and a temperature of 390.

More information

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM Sachin Kumar 1, Vicky Ranga 2 1Assistant Professor, Department of Mechanical Engineering, Jagan Nath University Jhajjar, Haryana, India. 2Scholar.

More information

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube

More information

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10 Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in

More information

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

Application of a hybrid control of expansion valves to a 3-ton large room cooling system 2123, Page 1 Application of a hybrid control of expansion valves to a 3-ton large room cooling system Christian K. Bach*, Eckhard A. Groll, James E. Braun Ray W. Herrick Laboratories, Purdue University,

More information

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential

More information

Mobile Heat Pump Exploration Using R445A and R744

Mobile Heat Pump Exploration Using R445A and R744 Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 04 Mobile Heat Pump Exploration Using R445A and R744 Andrew Musser Creative

More information

Experimental Study of Two-phase Seperators for Vapor Compression Systems in Household Appliances

Experimental Study of Two-phase Seperators for Vapor Compression Systems in Household Appliances Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Experimental Study of Two-phase Seperators for Vapor Compression Systems

More information

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek Department of Flow, Heat and Combustion Mechanics, Ghent University UGent,

More information

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Improving Heating Performance of a MPS Heat Pump System With Consideration

More information

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER Poster P.4.2 - - ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER Jan Sedlar, University Centre for Energy Efficient Buildings and Faculty of Mechanical Engineering, Czech Technical University in Prague, Czech

More information

Performance of a Transcritical CO 2 Heat Pump for Simultaneous Water Cooling and Heating

Performance of a Transcritical CO 2 Heat Pump for Simultaneous Water Cooling and Heating Performance of a Transcritical CO Heat Pump for Simultaneous Water Cooling and Heating J. Sarkar, Souvik Bhattacharyya, and M. Ramgopal Abstract This paper presents the experimental as well as the simulated

More information

Development of multi-function CO2 Heat Pump Water Heater

Development of multi-function CO2 Heat Pump Water Heater Development of multi-function CO2 Heat Pump Water Heater Background of multi-function water heater Market trend of gas combustion multi-function water heater X1000 400 200 1996 1997 1998 1999 2000 2001

More information

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser Issam Mohammed Ali Ahmed Qasim Mohammed Marwa Sallah Neama Mechanical Eng. Dept Air-

More information

Case 8 Basic Performance of Screw Compressor

Case 8 Basic Performance of Screw Compressor Case 8 Basic Performance of Screw Compressor Copy Right By: Thomas T.S. Wan ) June 24, 2010 All Rights Reserved Case Background: The basic rating and performance given by a compressor manufacturer is usually

More information

Experimental Study on the Performance of Twisted Capillary Tube

Experimental Study on the Performance of Twisted Capillary Tube Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Experimental Study on the Performance of wisted Capillary ube Amr O. Elsayed

More information

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature International Journal Of Computational Engineering Research (ijceronlinecom) Vol 3 Issue 3 Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

More information

Charge Minimization of Microchannel Heat Exchangers

Charge Minimization of Microchannel Heat Exchangers University of Illinois at Urbana-Champaign Air Conditioning and Refrigeration Center A National Science Foundation/University Cooperative Research Center Charge Minimization of Microchannel Heat Exchangers

More information

Effects of Refrigerant-Lubricant Combinations on the Energy Efficiency of a Convertible Split-System Residential Air-Conditioner

Effects of Refrigerant-Lubricant Combinations on the Energy Efficiency of a Convertible Split-System Residential Air-Conditioner Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 0 Effects of Refrigerant-Lubricant Combinations on the Energy Efficiency of

More information

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) 4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) Multi-stage Series Heat Pump Drying System with Dehumidification Simulation and Experiment Verification Chao

More information

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger "COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger" 1 Prof.Gaffar G.Momin, 2 Sagar B. Tupe, 2 Swapnil A. Parate 2 Omkar G. Yewale 2 Aakash P.

More information

Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners

Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners International Journal of Refrigeration 30 (2007) 546e564 www.elsevier.com/locate/ijrefrig Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners Haorong Li

More information

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Marco Alexandre Onofre Dias This paper presents a model that was implemented

More information

System Modeling of Gas Engine Driven Heat Pump

System Modeling of Gas Engine Driven Heat Pump Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 01 System Modeling of Gas Engine Driven Heat Pump Isaac Mahderekal shenb@ornl.gov

More information

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger , July 6-8, 2011, London, U.K. Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger Avinash. D. Desai, S. N. Sapali, Parthasarathi. V. Garikipati Abstract:

More information

January 16 th, 2014 New York City

January 16 th, 2014 New York City Compressor Calorimeter Test of R-404A Alternative Refrigerants ARM-31a, D2Y-65, L-40, and R-32/R- 134a (50/50) in Medium Temperature Refrigeration Scroll Compressor Som Shrestha Omar Abdelaziz January

More information

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 = 90 F. compressor. condenser. 5 evaporator 1. evap

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 = 90 F. compressor. condenser. 5 evaporator 1. evap 9.A-1 Dedicated subcooling is a novel modification for frozen food refrigeration in supermarkets. With the dedicated subcooling modification, liquid refrigerant leaving the condenser is further cooled

More information

Optimization of Heat Exchanger Design Parameters for Hydrocarbon Refrigerant Systems

Optimization of Heat Exchanger Design Parameters for Hydrocarbon Refrigerant Systems Optimization of Heat Exchanger Design Parameters for Hydrocarbon Refrigerant Systems S. Jain and C. W. Bullard ACRC TR-233 September 2004 For additional information: Air Conditioning and Refrigeration

More information

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical

More information

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Performance Characteristics and Optimization of a Dual-Loop Cycle for a

More information

Danfoss scroll compressors SH- In parallel installation

Danfoss scroll compressors SH- In parallel installation MAKING MODERN LIVING POSSIBLE Application guidelines Danfoss scroll compressors SH- In parallel installation 50 Hz - 60 Hz - R410A www.danfoss.com CONTENTS General overview...4 Benefits... 4 Scope...

More information

Santanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay

Santanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay Effect of Refrigerant Charge, Compressor Speed and Air Flow through the Evaporator on the Performance of an Automotive Air Conditioning System 15 th International Refrigeration and Air July 14-17, 2014

More information

Technical Information

Technical Information Date of last update: 02-08 Ref: Application Engineering Europe COPELAND SCROLL COMPRESSORS USING VAPOUR INJECTION FOR REFRIGERATION CONTENTS 1 Introduction...1 2 Principle of Operation...1 3 Capacity Effect...2

More information

Experimental Study of System Performance Improvements in Transcritical R744 Systems for Mobile Air-Conditioning and Heat Pumping

Experimental Study of System Performance Improvements in Transcritical R744 Systems for Mobile Air-Conditioning and Heat Pumping University of Illinois at Urbana-Champaign Air Conditioning and Refrigeration Center A National Science Foundation/University Cooperative Research Center Experimental Study of System Performance Improvements

More information

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Load Sharing Strategies in Multiple Compressor Refrigeration Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2 Load Sharing Strategies in Multiple Compressor Refrigeration Systems K. A.

More information

Virtual Refrigerant Pressure Sensors for Use in Monitoring and Fault Diagnosis of Vapor- Compression Equipment

Virtual Refrigerant Pressure Sensors for Use in Monitoring and Fault Diagnosis of Vapor- Compression Equipment HVAC&R Research ISSN: 1078-9669 (Print) 1938-5587 (Online) Journal homepage: http://www.tandfonline.com/loi/uhvc20 Virtual Refrigerant Pressure Sensors for Use in Monitoring and Fault Diagnosis of Vapor-

More information

Feasible Working Domains Decision Support for Heat Pump Projects

Feasible Working Domains Decision Support for Heat Pump Projects Downloaded from orbit.dtu.dk on: Nov 8, 17 Feasible Working Domains Decision Support for Heat Pump Projects Ommen, Torben Schmidt Publication date: 15 Document Version Peer reviewed version Link back to

More information

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System Devin Storle 1, Mohamed R.H. Abdel-Salam 2, Nader Pourmahmoud 3, Carey J. Simonson 4 1 MSc, University

More information

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1 HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil

More information

Experimental and Numerical Study on a Dryexpansion Shell-and-Tube Evaporator Used in Wastewater Source Heat Pump (WWSHP)

Experimental and Numerical Study on a Dryexpansion Shell-and-Tube Evaporator Used in Wastewater Source Heat Pump (WWSHP) Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Experimental and Numerical Study on a Dryexpansion Shell-and-Tube Evaporator

More information

Low GWP Refrigerants for Air Conditioning Applications

Low GWP Refrigerants for Air Conditioning Applications Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Low GWP Refrigerants for Air Conditioning Applications Samuel F. Yana Motta

More information

Heat Pump Clothes Dryer Model Development

Heat Pump Clothes Dryer Model Development Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Heat Pump Clothes Dryer Model Development Bo Shen Oak Ridge National Laboratories,

More information

Experimental Analysis of a Minimum-TEWI Air Conditioner Prototype

Experimental Analysis of a Minimum-TEWI Air Conditioner Prototype University of Illinois at Urbana-Champaign Air Conditioning and Refrigeration Center A National Science Foundation/University Cooperative Research Center Experimental Analysis of a Minimum-TEWI Air Conditioner

More information

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2002 Performance Comparisons Of A Unitary Split System Using Microchannel and

More information

Study of R161 Refrigerant for Residential Airconditioning

Study of R161 Refrigerant for Residential Airconditioning Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 212 Study of Refrigerant for Residential Airconditioning Applications Yingwen

More information

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #32 System Soft-Optimized Test of Refrigerant D2Y60 in Air Source

More information

PERFORMANCE EVALUATION OF GAS COOLER/ CONDENSER FOR CO2 REFRIGERATION SYSTEMS

PERFORMANCE EVALUATION OF GAS COOLER/ CONDENSER FOR CO2 REFRIGERATION SYSTEMS PERFORMANCE EVALUATION OF GAS COOLER/ CONDENSER FOR CO2 REFRIGERATION SYSTEMS Yunting Ge (a) IDewa Santosa (a), Konstantinos Tsamos (a), Savvas Tassou (a) Nick Atkins (b), Simon Jones (b) (a) School of

More information

Scroll Compressor for Mobile HVAC/R Application

Scroll Compressor for Mobile HVAC/R Application Purdue University Purdue e-pubs International ompressor Engineering onference School of Mechanical Engineering 2004 Scroll ompressor for Mobile HVA/R Application Michael M. Perevozchikov opeland orporation

More information

Comparison of fin-and-tube interlaced and face split evaporators with flow maldistribution

Comparison of fin-and-tube interlaced and face split evaporators with flow maldistribution Downloaded from orbit.dtu.dk on: Oct 22, 2018 Comparison of fin-and-tube interlaced and face split evaporators with flow maldistribution and compensation Kærn, Martin Ryhl; Elmegaard, Brian; Larsen, L.F.S.

More information

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Low Global Warming Refrigerants For Commercial Refrigeration Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Low Global Warming Refrigerants For Commercial Refrigeration Systems Samuel

More information

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance

More information

Air Cooled Packaged Systems AIRAH Back to Basics

Air Cooled Packaged Systems AIRAH Back to Basics Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability

More information

A fair comparison of CO2 and propane used in light commercial applications featuring natural refrigerants

A fair comparison of CO2 and propane used in light commercial applications featuring natural refrigerants Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 A fair comparison of CO2 and propane used in light commercial applications

More information

2. HEAT EXCHANGERS MESA

2. HEAT EXCHANGERS MESA 1. INTRODUCTION Multiport minichannel and microchannel aluminium tubes are becoming more popular as components in heat exchangers. These heat exchangers are used in various industrial applications and

More information

Danfoss scroll compressors SH - In parallel installation

Danfoss scroll compressors SH - In parallel installation Application guidelines Danfoss scroll compressors SH - In parallel installation 50 Hz - 60 Hz - R410A http://cc.danfoss.com Contents General overview... 5 Benefits... 5 Scope... 5 Design challenge...

More information

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater Purdue University Purdue epubs International Compressor Engineering Conference School of Mechanical Engineering 2012 Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater Youhei

More information

Evaluation of a Virtual Refrigerant Charge Sensor

Evaluation of a Virtual Refrigerant Charge Sensor Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Evaluation of a Virtual Refrigerant Charge Sensor Woohyun Kim Purdue University

More information

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1. 568, Page Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors Jose N. FONSECA *, Rodrigo KREMER, Thiago DUTRA 2 EMBRACO, Research & Development Group, Joinville, Santa Catarina,

More information

Transcritical Carbon Dioxide Microchannel Heat Pump Water Heaters: Part II - System Simulation and Optimization

Transcritical Carbon Dioxide Microchannel Heat Pump Water Heaters: Part II - System Simulation and Optimization Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 ranscritical Carbon Dioxide Microchannel Heat Pump Water Heaters: Part

More information

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM - 1 - EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM Shun YOSHIOKA, Hyunyoung KIM, Kazushige KASAI, Daikin Industries,

More information