CONTENTS. Air-Cooled Screw Chiller Technical Sales Guide NOMENCLATURE FEATURES MODELS LIST

Size: px
Start display at page:

Download "CONTENTS. Air-Cooled Screw Chiller Technical Sales Guide NOMENCLATURE FEATURES MODELS LIST"

Transcription

1

2 CNTENT 2 NMENCLATURE 1 1.MDEL LIT 2.NMENCLATURE.FEATURE 4.PRDUCT DATA 6 5.PERFRMANCE CRRECTIN 8 6.ANTIFREEZE 9 7.INTALLATIN 9 8.ELECTRICAL DATA 11 9.ELECTRICAL DIAGRAM CHEMATIC WIRING DIAGRAM WIRE CNTRLLER MICRPRCER CNTRLLER 19 1.LNG-DITANCE MNITRING YTEM CENTRAL AC BM INTERFACE 2 15.APPLICATIN DATA 28 MDEL LIT Nominal Capacity Ton Refrigerant R14a Model Model Name LBLGF20MT/Nb-M LBLGF50MT/Nb-M LBLGF40MT/Nb-M Power upply Ph, V, Hz,80,50,80,50,80,50 2 L BLG F 20 T Water chiller crew compressor Air cooled Nominal Cooling Capacity uper high ambient operation 52 /125 L BLG F 20 M T /Nb-M Model ignification ptions 20=20kW= 784 kbtu/h 50=50kW= 1194 kbtu/h 40=40kW= 1467 kbtu/h M Modular Nb Refrigerant Nb-R14a M Voltage M 80V N~ 50Hz FEATURE.1 Description The kw models are shipped from the factory complete ready for installation and use. The unit is pressure-tested, evacuated, and fully charged with R14a and has an initial oil charge. R14a has no ozone depletion potential. It is environmentally safe and does not have a phase-out date. After assembly, a complete operation test is performed with water flowing through the cooler to assure that the refrigerating circuit operates correctly. The units can be installed on the rooftop, ground outside and so on, instead of being equipped in a special machine room. It can be widely applied in newbuilt or reconstructed industry and civil-building project, such as hotel, apartment,restaur-ant, office building, shopping mall, theater, gymnasium, hospital and so on, as well as supplies required cooling water for factories in technical process of producing, so it's especially suitable for some special locations around where there are high-level requirements for noise and environments and cooling tower are difficult to install..2 tandard pecifications High Efficiency Full Load peration Utilizing new screw compressor technology, the chillers meet or exceed the performance requirements of AHRAE All system components are selected for optimum performance, including the condenser coil areas and evaporator sizes. 2 GREE Central Air Conditioners GREE Central Air Conditioners

3 Excellent Part Load Performance By using compressor on each chiller, unloading characteristics and part load performance are outstanding. Integrated part load value (IPLV) is a part load performance indicator as outlined in tandard ARI 550/ The IPLV rating compares the performance of different chillers under identical conditions. When the IPLV is listed as EER (Energy Efficiency Ratio), a higher EER will indicate that the chiller's overall performance is better. Compact Design with mall Footprint The chillers have a reputation for a compact design and small footprint. A small footprint can save installation costs by minimizing the size of the concrete mounting pad or reduces the amount of structural steel if the unit is mounted on the rooftop. Quiet peration The chillers are designed with quiet screw compressors. Fans are selected for good performance and lower sound levels. The attention to detail with sound is critical in the design. mall issues such as refrigerant piping, supports for piping, securing components to the structure are all important to making a quiet product. We proudly publish our sound performance. uperior Controls GREE has provided the latest technology in controlling the chillers. The new controller provides a user friendly environment for the operator. The control logic is designed to provide maximum efficiency, to help provide continuing operation in unusual operating conditions through proactive controls, and to provide a history of conditions to aid in problem resolutions. Perhaps the greatest benefit is Protocol for integrating with your building automation system (BA). The interface with the BA standard protocols through Modbus. Evaporator The evaporator is direct expansion, shell-and-tube type with water flowing in the baffled shell side and refrigerant flowing through the tubes. The evaporator has a carbon steel fin and seamless high efficiency copper tubes roller expanded into a carbon steel tube sheet. Refrigerant heads are carbon steel with multi-pass baffles to provide oil return and are removable to permit access to the tubes from either end. For water removal, 10mm vent and drain plugs are provided on the top and bottom of the shell. An ambient air thermostat controls the heater cable. The fitted and glued in place insulation has a K factor of The refrigerant side maximum operating pressure is 2068 kpa. The water side operating pressure is 1048 kpa. Each evaporator is designed, constructed, inspected, and stamped according to the requirements of the AME Boiler and Pressure Vessel Code. Condenser Condenser coils have internally enhanced seamless copper tubes arranged in a staggered row pattern. The coils are mechanically expanded into louver aluminum fins with full fin collars. A variety of optional coil material and coatings are available for corrosive atmospheres. The external condenser coils are fitted with a protective wire mesh guard. everal optional coil materials are available for corrosive atmospheres. Fans-The condenser fans are composed of corrosion resistant aluminum hub and glass-fiberreinforced polypropylene composite blades molded into a low noise airfoil section. They are designed for maximum efficiency and are statically and dynamically balanced for vibration-free operation. They are directly driven by independent motors, and positioned for vertical air discharge. The fan guards are constructed of heavy-gauge, rust-resistant, coated steel. All blades are statically and dynamically balanced for vibration-free operation. Motors-The fan motors are totally enclosed air-over, squirrel-cage type, current protected. They feature ball bearings that are double-sealed and permanently lubricated. Microprocessor Controller The chiller's Unit Control Module is an innovative, modular microprocessor control design. It coordinates the actions of the chiller in an efficient manner and provides stand-alone operation of the unit. A Human Interface Panel is a standard component of the Chiller. Access to all unit controls is via the Human Interface Panel. Compressor uction gas cooled semi-hermetic compact twin screw compressors with high efficiency profile. Compressors are provided with high efficiency suction strainer, oil trainer crank case heater and built in safety pressure relief valve. Compressors are also provided with intelligent electronics including motor temperature monitoring, phase sequence monitoring, manual reset lockout and discharge temperature protection by PTC`s sensors. ptimized oil management ensure minimum refrigerant dilution in oil. Water Flow witch A water flow switch is available for field installation in the chilled water piping to protect against evaporator freeze-up under low, or no flow conditions. Terminals are provided in the unit control center for field connection of the water flow detection switch. A flow detection device of some type is required. Pump utput ignal Provides a digital output to control a second chilled water pump. tandard unit has one pump output. High Ambient peration This option is required for operation at ambient temperatures above 46, up to 52 or when the unit is equipped with the low ambient fan control option. The option can be ordered with any unit. Compressor loading and unloading is adaptively determined by system load, ambient air temperature and other inputs to the control algorithms. Construction The "W" shaped coil provides excellent headroom under the unit for inspection and service. It allows less installation space requirement. Heavy structure unit with waterproof, electro-static, polyester powder painted. 4 GREE Central Air Conditioners GREE Central Air Conditioners 5

4 4 The patented design of that any unitary module can be as master module, makes various emergencies easy. Each unitary module can be combined with another module with different capacity so that different units with different cooling capacity are formed in a wider application range. Balanced running of compressor extends the lifetime of unit. The compressor of each unitary module will be started one after another to ensure less attack to power network. The design of combination of modular makes the unit compact in size and configuration, convenient in delivery and installation.. tandard Accessories Unit on-off switch: N-FF switch is provided for manually switching the unit control circuit. Indicator lights: LED lights indicate power on to unit, running state and fault indications due to safety devices. Filter drier: Refrigerant circuits are kept free of moisture, sludge, acid and oil contamination by filter. Under voltage and phase protection: Protects against low incoming voltage as well as single phasing, phase reversal. ight glass: An easy-to-read color indicator shows moisture contents and provides a mean for checking the system refrigerant charge. Liquid line solenoid valve: Closes when the compressor is off to prevent any liquid refrigerant from accumulating in the evaporator..4 tandard Control & afety Devices afety valve: Protects the unit against high discharge pressure. Compressor In-built protection device: Motor winding temperature, discharge gas temperature and phase reversal for direction of rotation. Crankcase heaters: Protects the unit against refrigerant migration, oil dilution and potential compressor failure. PRDUCT DATA 4.1 Ratings Model LBLGF20MT/Nb-M LBLGF50MT/Nb-M LBLGF40MT/Nb-M Capacity kw / kbtu/h 20 / / / 1467 EER EER=Energy Efficiency Ratio at full load-the cooling capacity in Btu per hour(btu/h) divided by the power input in watts, expressed in Btu/h per watt((btu/h)/watt). 4.2 Unit Application Data Voltage Variation 80V N 50Hz 42/420 Min./Max. Ambient Air on Condenser coil Min./Max. ( ) 18/52 ( 65/125) 4. Physical Data Models Nominal Cooling Capacity Input Power Power upply Running Control afety Apparatus Compressor Type Refrigerant Charge Cooler Conde -nser Dimen -sion Refrigerant Type Water Flow Max. Pressure Water In/ut Pipe Diameter kw kbtu/h TR kw kg m /h Loss of Pressure kpa Heat Exchanger Heat Exchanger Fan Motor Power Input Height Width Depth hipping Weights peration Weights NTE: 1 mm=0.094 in MPa mm LBLGFMT /Nb-M V N~ 50Hz Microcomputer auto control, running status display, abnormal status alarm High/low pressure protection, discharge temp. protection,motor overload protection, anti-freeze, water flow protection, low water flow protection, phase-sequence protection, compressor overload protection, compressor inset protection,pressure differential protection emi-hermitic crew Compressor R14a GPM hell and Tube Evaporator 1.0 DN100 DN100 DN125 Finned Coil Type Condenser kw 2X4 2X6 2X8 mm mm mm kg kg GREE Central Air Conditioners GREE Central Air Conditioners 7

5 5 PERFRMANCE CRRECTIN Performance Correction 6 ANTIFREEZE Ethylene Glycol Factors Leaving Chilled Water ( ) 5(41) 6(42.8) 7(44.6) 8(46.4) 9(48.2) 10(50) 11(51.8) 12(5.6) 1(55.4) 14(57.2) 15(59) 25(77) (86) Ambient Temperature ( ) 5(95) 40(104) 45(11) (122) (11) The units can operate with a leaving chilled fluid temperature from of 20 to 60. A glycol solution is required when leaving chilled fluid temperature is below 4.5.The use of glycol will reduce the performance of the unit depending on concentration. % by Weight Freezing Point Ambient Temperature Cooling Capacity Correction Factor Water flow Correction Factor Pressure Drop Correction Factor 10 -.(26) 8.(47) (18) -1.7(29) (7) -6.7(20) (-7) -.(-29) -16.7(2) -26.7(-16) NTE: Ethylene and propylene glycol ratings are outside the scope of ARI tandard 550/ certification program. Cooling Capacity kw Ambient Temperature Cooling Capacity kw Ambient Temperature 7 INTALLATIN 7.1 Dimensions Chilled Water Temperature LBLGF20MT/Nb-M Chilled Water Temperature LBLGF50MT/Nb-M Water utlet Water Inlet C F Cooling Capacity kw Chilled Water Temperature LBLGF40MT/Nb-M Ambient Temperature Model LBLGF20MT/Nb-M LBLGF50MT/Nb-M LBLGF40MT/Nb-M D A A B E C D B E F GREE Central Air Conditioners GREE Central Air Conditioners 9

6 7.2 Rigging Instruction Attention to Riggers The center of gravity is not along unit center line. Ensure that the center of gravity aligns with the main lifting point before lifting. Use spreader bar when rigging, to prevent the slings during the unit. Caution All panels should be in place when rigging. Care must be taken to avoid damage to the coils during handling. Insert packing material between coils and slings as necessary. 7.4 Load Distribution Model R 1 R 2 R R 4 R 5 R 6 LBLGF20MT/Nb-M LBLGF50MT/Nb-M LBLGF40TM/Nb-H Installation Interspace LIFT LIFT 000 preader Bar PRPER INTERPACE T BE PRVIDED Mounting Location R6 R5 R ELECTRICAL DATA Model A R1 A R2 R LBLGF20MT/Nb-M LBLGF50MT/Nb-M A 150 LBLGF40MT/Nb-M Model LBLGF20MT/Nb-M LBLGF50MT/Nb-M Area of Electrical Wire 2 150mm 2 185mm LBLGF40MT/Nb-M 2 240mm 10 GREE Central Air Conditioners GREE Central Air Conditioners 11

7 9 ELECTRICAL DIAGRAM LBLGF20MT/Nb-M LBLGF50MT/Nb-M 12 GREE Central Air Conditioners GREE Central Air Conditioners 1

8 LBLGF40MT/Nb-M 10 CHEMATIC WIRING DIAGRAM ELECTRIC BX FIELD CNTRL WIRING ENTRANCE MAIN PWER ENTRANCE TYPICAL CNTRL BX LCATIN AND FIELD WIRING FIELD CNTRL WIRING CNNECTIN LEGEND MAIN PWER WIRING CNNECTIN 14 GREE Central Air Conditioners GREE Central Air Conditioners 15

9 11 CMMUNICATIN WIRING CNNECTIN AND ETTING WIRE CNTRLLER peration View N. Name Function description Power Run Error n/ff Reset The light is on when power connection is available, or else it is off. The light is on when unit is under operation, or else it is off the light is on when unit has any malfunction It is used to turn on or off the unit. Press the button for seconds when unit is off to turn on unit, press it for seconds when unit is on to turn off the unit. The button can't be press continuously Press it for second, the system can clear previous errors and run self-detected automatically again. This button cannot be pressed continuously 6 7 N. Name Function description Exit Enter LCD Menu structure of controller Heat pump type Main Control Menu Main Menu Paramter etting Module View User setting Version Module 1 In menu selection, press this button to move cursor to up or left one item; When setting parameter, press this button to increase the value. This button can be pressed continuously In menu selection, press this button to move cursor to down or right one item; when setting parameter, press this button to decrease the value. This button can be pressed continuously Press it to back to previous menu. This button can be pressed continuously In menu selection, press it to select item and enter below menu; When setting parameter, press it to save adjustment and move cursor. This button can be pressed continuously the area for displaying information User Par.. etting ys Par. Etting Debugging tartup Mode ound Backlight Auto Antifre. Auxiliary Heat Clock etting Timer etting Module 2 Module Module 4 Module 5 Module 6 Module 7 Module 8 Enter Password Password Change Tempe -rature View Water-out T Water-in T Defrost T Ambient T Antifre T. Discha-rge T. Pressure View High Pressure Low Pressure il Pressure tate View etting Par. by manual Compressor Fan 1 Fan 2 Fan 4-way valve Auxi-heat 1 Auxi-heat 2 ys tate Error View Previous Error Present Error Adopt default Par. C Water-in T. Defrost Intl Defrost Dur Adj. C Rate t C Rate Module 1 Module 2 Module Module 4 Module 5 Module 6 Module 7 Module 8 Force Defrost H Water-in T tartup Intl Adj. Intl il P Dif ys P Dif Antifre. Anti-ovh Auxi-heat n Auxi-heat ff. Defrost n Defrost ff 16 GREE Central Air Conditioners GREE Central Air Conditioners 17

10 Cooling only type Main Control Menu Main Menu Paramter etting Module View User setting Version tartup ound Backlight Clock etting Module 1 Module 2 Module Module 4 Module 5 Module 6 Module 7 Module 8 User Par.. etting ys Par. Etting Enter Password etting Par. by manual Password Change Timer etting Tempe -rature View Adj. C Rate Water-out T Water-in T Antifre T. Discha-rge T. Pressure View High Pressure Low Pressure il Pressure tate View Compressor Fan 1 Fan 2 Fan t C Rate ys tate Error View Previous Error Present Error Adopt default Par. C Water-in T. tartup Intl Adj. Intl il P Dif ys P Dif Antifre. Accessories =tandard =ptional P=Provide for oneself Model Accessories Name Module unit Display board Four-core control connection cord (8 meters) Water flow switch and water flow switch control board Electric control box Auxiliary electric heater Power connection wire Control connection cord Flexible joint Thermometer Pressure gauge Water tank Cooling only Heat pump P 12 MICRPRCER CNTRLLER Microprocessor Control The microprocessor controls overall unit operation and controls a number of processes simultaneously. These processes include internal timers, reading inputs, analog to digital conversions, fan control, display control, diagnostic control, output relay control, demand limit, capacity control, head pressure control, and temperature reset. ome processes are updated almost continuously, others every 2 to seconds, and some every 0 seconds. The microprocessor routine is started by switching the Emergency N-FF switch to N position. Pump control of. External pumps (where configured) will energize the cooler pump to the input occupied signal from external system. When the unit receives a call for cooling, the unit stages up in capacity to maintain the cooler fluid set point. The first unit starts 1 to minutes after the call for cooling. The microprocessor controls the capacity of the chiller and the loading capacity to satisfy actual dynamic load conditions. The control maintains leaving-fluid temperature set point shown on the panel interface through intelligent positioning of the slide valve and compressor cycling. Accuracy depends on loop volume, loop flow rate, load, and outdoor-air temperature. No adjustment for cooling range or cooler flow rate is required, because the control automatically compensates for cooling range by measuring both return-fluid temperature and leaving-fluid temperature. This is referred to as leaving-fluid temperature control with return-fluid temperature compensation. The basic logic for determining when to add or remove capacity is a time band integration of deviation from set point plus rate of change of leaving-fluid temperature. Control equence tart-up After control circuit switches on, the pre-start process takes place, then microprocessor checks itself, starts pump and waits for temperature to stabilize. The controlled pull down feature limits compressor loading on start-up to reduce demand on start-up and unnecessary compressor usage. Capacity control n the first call for cooling, the microprocessor starts compressor and fan stage on lead unit. As additional cooling is required, the capacity of the compressor is increased by changing the position of the slide valve. As the load increases above the compressor's capacity, another unit's compressor is started and both staged together. The speed at which capacity is added or reduced is controlled by temperature deviation from set point and rate of temperature change of chilled fluid. The Main Base Board (MBB) responds to the supply chilled water temperature to cycle the compressors to match cooling load requirements. The Minimum Load control valve is energized by the MBB. The valve allows hot gas to pass directly into the cooler circuit on the initial step of unloading, permitting the unit to operate at lower loads with less compressor cycling. ensors Thermistors are used to control temperature-sensing inputs to the microprocessor. No additional thermistor sensors are required for optional leaving chilled water temperature, return water, or outdoor air. Two refrigerant pressure transducers are used for sensing suction and discharge pressure. The microprocessor uses these inputs to control capacity and fan cycling. 18 GREE Central Air Conditioners GREE Central Air Conditioners 19

11 1 LNG-DITANCE MNITRING YTEM 4-core crystal phone plug 1.1 Introduction to Long-distance Monitoring ystem As the development and improvement of manufacturing technology and in order to solve the problems of complex distribution of the central AC in the buildings and difficult control and maintenance of them, an platform easy and reliable to operate must be provided to the users for daily management and maintenance. o this long-distance monitoring system combining electronic communication and computer technologies is developed to collect the running state of the units and to monitor and control the units from a long distance. 1.2 Installation and election. Crystal phone plug 485 A line 485 B line Notice 1.The address code of the communication modules should not be conflicted in one project. 2.ptoelectronic Isolated Repeater: every 800m of communication distance equipped needs one and every 0 communication modules equipped needs one. cope of upply cope of upply Communication module set FE0-22/E =tandard parts; = User ptional; P= User Provided Parts Type election PC P Please check 7.Installation Criteria Air cooled screw (heat pump) chiller Long-distance Monitoring ystem set FE0-22A(M) ptoelectronic isolated repeater Rs485 4-core twisted pair wire -way phone connector P P Remarks Including communication module ZJ522, power transformer and connecting wire Including CD and optoelectronic isolated converter Rs22- Rs485 ne every 800m of communication distance equipped with one and ne every 0 communication modules equipped with one. Confirmation of Quantity of Parts Types Qty of Communication Modules Long-distance Monitoring ystem ptoelectronic Isolated Repeater.the communication cable and heavy-current wire should be separated and the distance between them can not be below 15cm. 4.line A and line B of Bus 485 should respectively correspond with line A and line B. 5.crystal head(crystal head buckle is downwards). All type ne unit equipped with a communication module ZJ522 1 Air cooled screw (heat pump) chiller Long-distance Monitoring ystem set FE0-22A(M ne every 800m of communication distance equipped with one. ne every 0 communication modules equipped with one 20 GREE Central Air Conditioners GREE Central Air Conditioners 21

12 election Example sets of units LBLGRF250M, 4 communication modules are needed, the communication distance is above 800m, then one repeater is necessary, and the quantity of communication modules is below 0 the repeater is unnecessary, as follow: Project Requirements Communication module set FE0-22/E Quantity Qty set (LBLGRF250M) Description of above communication cables Cable D H2 Description Crystal head and the other end is XH 4-core pin connector 2-core Type-V twisted pair wire both crystal head(tandard parts) crystal head and the other end connects of it connects with wiring terminal of converter. (2-core Type-V twisted pair wire both 9-core head (tandard parts) Air cooled screw (heat pump) chiller Long-distance Monitoring ystem set FE0-22A(M) Repeater Wiring Diagram Network 1 Unit Module1 Unit Module8 Unit Module1 Unit Module CENTRAL AC BM INTERFACE Introduction to BM interface of Gree Central AC BM interface of Gree Central AC is only for Gree central AC devices. There is BM interface or multifunctional gateway in the hardware and standard communication protocol and BM software plug-in in the software. Gree central AC can be centrally monitored and managed through BM interface together with other devices in the building. Displayer 1 Displayer n CM1 CM1 CM2 CM2 onitoring Center ZJ5221 ZJ5222 ZJ522n PC H2 R Converter Network n Unit Module1 Unit Module8 Unit Module1 Unit Module8 R+/D+---Rs485A R-/D---Rs485B Displayer m Displayer 254 D CM2 CM Installation and election ZJ522m ZJ522m+1 ZJ Notice 1.The air conditioners could be connected with the BM system with every different model, or several models together, below wiring diagram shows the connection way of single unit, just for easy drawing. ( Please check 1.2) 22 GREE Central Air Conditioners GREE Central Air Conditioners 2

13 cope of upply Wiring Diagram =tandard parts; = User ptional; P= User Provided Parts cope of upply Type election Remarks File of protocol Modbus protocol is used for user to integrate with BM system. Communication module FE0-22/E Long distance monitoring set FE0-22A(M) optoelectronic isolated converter Rs22- Rs485 ptoelectronic isolated repeater Rs485 4-core twisted pair wire -way phone connector P P Including communication module ZJ522, power transformer and connecting wire Including CD and optoelectronic isolated converter Rs22- Rs485 It is needed when the interface protocol of BM system is Rs22 ne every 800m of communication distance equipped with one and ne every 0 communication modules equipped with one. Unit Module1 Unit Module8 Unit Module1 Unit Module8 CM1 ZJ5221 Displayer 1 CM2 CM2 ZJ5222 Network 1 CM2 ZJ522n Displayer n Just for Rs22 interface of BM BM Confirmation of Quantity of Parts Types Qty of Communication Modules ptoelectronic isolated converter ptoelectronic Isolated Repeater Network n Unit Module1 Unit Module8 Unit Module1 Unit Module8 R Converter R+/D+---Rs485A R-/D---Rs485B All type ne unit equipped with a communication module ZJ522 ne if BM CM is Rs22 ne every 800m of communication distance equipped with one. ne every 0 communication modules equipped with one. CM2 Displayer m Displayer 254 CM2 ZJ522m ZJ522m+1 ZJ D election Example BM CM is R22,one converter is needed. sets of units LBLGRF250M, 4 communication modules are needed, the communication distance is above 800m and one repeater is necessary and the quantity of communication modules is below 0 repeater is unnecessary, as follow: Project Requirements Quantity Qty set (LBLGRF250M) Communication module set FE0-22/E Repeater ptoelectronic Isolated Converter 1 1 Description of above communication cables Cable Description Crystal head and the other end is XH 4-core pin connector both crystal head(tandard parts) D crystal head and the other end connects of it connects with wiring terminal of converter. 24 GREE Central Air Conditioners GREE Central Air Conditioners 25

14 14 APPLICATIN DATA Unit Location The chillers are designed for outdoor installation. When selecting a site for installation, be guided by the following conditions: 1. For outdoor locations of the unit, select a place having an adequate supply of fresh air for the condenser. 2. Avoid locations beneath windows or between structures where normal operating sounds may be objectionable.. Installation sites may be either on a roof, or at ground level. 4. The condenser fans are the propeller-type, and are not recommended for use with duct work in the condenser air stream. 5. When it is desirable to surround the unit(s), it is recommended that the screening be able to pass the required chiller CFM without exceeding 0.1" of water external static pressure. 6.Recommended clearances for units are given in DIMENIN. When the available space is less, the unit(s) must be equipped with the discharge pressure transdu-cer option to permit high pressure unloading in the event that air recirculation were to occur. Foundation The unit should be mounted on a flat and level foundation, ground or roof, capable of supporting the entire operating weight of the equipment. perating weights are given in the Dimension. For ground level installations, precautions should be taken to protect the unit from being tampered by or injuring to unauthorized persons. crews on access panels will prevent casual tamper-ing; however, further safety precautions, such as unit enclosure options, a fenced-in enclosure, or locking devices on the panels may be advisable. Check local authorities for safety regulations. Chilled Liquid Piping The chilled liquid piping system should be laid out so that the circulating pump dis-charges into the cooler. The inlet and outlet cooler liquid connections are given in Dimension Delivery and Handling A.Unit shall be delivered to job site fully assembled, and charged with refrigerant and oil by the manufacturer. B.Unit shall be stored and handled according to the manufacturer'sinstructions. Leveling Unit Unit must be leveled when installed to ensure proper oil return to the compressors. Fluit Temperature Maximum leaving chilled fluid temperature for unit is 59 (15 ). For continuous operation, it is recommended that inlet fluid temperature does not exceed 86F(0 ) ( If continuous operation is required for inlet water temperature above 86 (0 ), please contact GREE factory). Minimum leaving chilled fluid temperature for standard unit is 8 (. ) (For lower leaving temperature contact GREE factory). Cooler Flowrange: Chiller ratings and performance data pertain to cooling temperature rise of 10. Chillers maybe suitable for operation in a range from 5.4 to 14.5 temperature rise without adjustment, provided flow limits are not exceeded. High flow rate is limited by pressure drop that can be tolerated ( for any high flow rate value larger than values in performance tables, please contact GREE factory). Minimum Cooler Flow: Minimum cooler flow will be based on the maximum permissible AT across the cooler 14.5 Maximum Cooler Flow: It Will be based on Minimum permissible AT across the cooler 5.4 Cooler Protection A protection against low ambient freeze-up is required for ambient temperatures below 2 (0 ). Protection should be in the form of: Inhibited ethylene glycol or any other suitable glycol. Condenser Airflow Any restrictions on units fan airflow will affect unit capacity, condenser head pressure, and compressor power input. uch restrictions (i.e. not providing vertical clearance or lateral clearance, insufficient unit-to-unit clearance ) will cause warm air re-circulation or coil starvation. Minimum required operational and maintenance clearances around the unit are shown in the figure below. High Ambient Temperature High outdoor ambient chiller start-up and operation are possible for chillers at ambient temperatures up to ) at nominal voltage (for standard units). For higher ambient temperature please contact GREE factory. 2 GREE Central Air Conditioners GREE Central Air Conditioners 24

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M 1. MODELS LIST 1. NOMENCLATURE 3 3. FEATURES 3 4. PRODUCT DATA 6 5. PERFORMANCE CORRECTION 9 6. ANTIFREEZE 1 7. INSTALLATION 13 8. ELECTRICAL DATA 16 9. ELECTRICAL DIAGRAM 17 10. SCHEMATIC WIRING DIAGRAM

More information

Contents 1. MODELS LIST 9. ELECTRICAL DIAGRAM MODELS LIST

Contents 1. MODELS LIST 9. ELECTRICAL DIAGRAM MODELS LIST Contents 1. MODELS LIST 2.NOMENCLATURE 3.FEATURES 4.PRODUCT DATA 5.PERFORMANCE CORRECTION 6.ANTIFREEZE 7.INSTALLATION 8.ELECTRICAL DATA 9. ELECTRICAL DIAGRAM 10.FIELD WIRING DIAGRAM 11.MICROPROCESSOR CONTROLLER

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

CASE STUDY AIR-CONDITIONERS

CASE STUDY AIR-CONDITIONERS CASE STUDY AIR-CONDITIONERS An Investment in Longer Lasting Quality ABOUT US BT Commercial Ltd. is a dynamic and diversified company, which has been in operation since 1992. Our company, which is growing

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: , DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies

More information

SECTION AIR COOLED WATER CHILLERS

SECTION AIR COOLED WATER CHILLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered

More information

30HXC Nominal cooling capacity kw

30HXC Nominal cooling capacity kw WTER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 0HXC Nominal cooling capacity 286-102 kw The 0HXC units are water-cooled chillers, designed from the ground up to meet the needs of today and tomorrow: - Non-ozone

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz 30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

PACKAGED AIR COOLED Product Data Catalog

PACKAGED AIR COOLED Product Data Catalog PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

Product Chillers A P P L I C AT I O N S

Product Chillers A P P L I C AT I O N S Product Chillers A P P L I C AT I O N S Wineries Bottling Product Storage Product Ripening Meat Processing Florist Boxes Packaging Rooms Walk-in Coolers Beverage Boxes CENTURY PRODUCT CHILLERS Unit Configuration

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 141 kw to 360 kw YORK YCAL-SB Millennium air cooled scroll liquid chillers provide chilled liquid for all air conditioning

More information

Air-Cooled Global Chiller

Air-Cooled Global Chiller Product Manual PM 970 Group: Chiller Effective: June 1997 Supersedes: None Air-Cooled Global Chiller Type AGR 055AS through 100AS Reciprocating Compressor with R-22 60 hertz 1997 McQuay International Table

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil. 1 1 1 1 1 1 1 1 0 1 0 1 SECTION 1 PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days Proposal Trane A Division of American Standard Inc. Prepared For: John Weston Desmet Ballestra Job Name: LAUER1 Biodiesel Chiller Pennsylvania Date: August 21, 2006 Proposal Number: G1-95502-1 Engineer:

More information

Scroll Water Cooled Chiller

Scroll Water Cooled Chiller Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

Screw Water Cooled Chiller SCW210

Screw Water Cooled Chiller SCW210 Screw Water Cooled Chiller SCW210 Nominal Cooling Capacity 185.1 to1480.8 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

MODELS W1LC220, 260 AND 320 STYLE B

MODELS W1LC220, 260 AND 320 STYLE B LIQUID CHILLER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: 570.05-NY (494) 570.05-N3Y (495) MODELS WLC0, 60 AND 30 STYLE B 035-3053 Only -5 and -46 voltage codes GENERAL YORK s WLC Packaged Air-Cooled

More information

The six in-house brands are Classic, Cooline, CoolCare, Clima Tech, Geoclima and Kessler Clima Tech.

The six in-house brands are Classic, Cooline, CoolCare, Clima Tech, Geoclima and Kessler Clima Tech. Company Business Zamil Air Conditioners was founded in 1974, and is the first major business venture in manufacturing sector for the Al Zamil group of Companies. It is also the first manufacturing unit

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Leadership, Innovation, Advanced Technology Synergise Here!

Leadership, Innovation, Advanced Technology Synergise Here! Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified

More information

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC. WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS SECTION 236200 - PACKAGED COMPRESSOR AND CONDENSER UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw Air-to-Water Heat Pumps with Integrated Hydronic Module AQUASNAP Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products.

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program. 15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode R0A (kw-0kw) 0Hz KJR-0B/BE is a human-machine interaction(hmi) used for the communication between chiller operator and main board on the chiller itself. The setting and operation order can be send to the

More information

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1 TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system

More information

Be sustainable while protecting your business

Be sustainable while protecting your business Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair

More information

3 0 H X C A - H P 2

3 0 H X C A - H P 2 3 0 H X C 1 3 0 A - H P 2 Max. Leaving Water Temperature (Heating Mode) 1 for 47 O C,2 for 60 O C Water-to-Water Screw Heat Pump 3 rd Generation Global Water Cooled Chiller Norminal Capacity (USRT) Carrier

More information

NQ Series Portable Chillers

NQ Series Portable Chillers NQ Series Portable Chillers Electrical Components Mounted and Wired All electrical components and sensors are mounted, wired, and fully tested at the factory to reduce installation time and ensure the

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information