1 Ozone Systems... Installation & Maintenance Manual CD15/AD & M15AD Corona Discharge Ozone Generator ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca Fax: Copyright ClearWater Tech, LLC. Reproduction of any kind is prohibited Rev. 0795
2 IMPORTANT SAFETY INSTRUCTIONS 1. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS. 2. All electrical connections should be made by a licensed, qualified electrician. 3. Before attempting any electrical connections, be sure all power is off at the main circuit breaker. 4. Install the ozone generator using nonmetallic plumbing. 5. Install the provided ozone check valves to prevent water from contacting the electrical equipment. 6. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section of the National Electrical Code, ANSI/NFPA The means of disconnecting the equipment must be readily accessible to the operator(s). 7. Be sure to bond (ground) the system using the copper bonding lug on the bottom of the system. The system should be bonded with solid copper wire conforming with all local, state and national electrical codes. 8. Ambient temperature around the equipment should be between 40 and 100 F (4.5 to 38 C). If the equipment is installed in an environment with temperatures over 100 F, additional air cooling must be provided. Installation without additional air cooling in an environment where temperatures exceed 100 F for any continuous 24 hour period will void the warranty. 9. The system should be sized appropriately for its intended use by a qualified professional familiar with the application. This equipment must be validated by the manufacturer for its intended use. 10. SAVE THESE INSTRUCTIONS.
3 PRODUCT DESCRIPTION CORONA DISCHARGE (CD) OZONE SYSTEMS Ozone is manufactured in the CD ozone generator by drawing in air, which is composed of 20% oxygen (O 2 ), and exposing it to multiple high voltage electrical discharges. This causes the oxygen molecules to dissociate and reassemble as ozone (O 3 ). The ozone is drawn into the water by an injector/mixer, killing any bacteria, viruses or mold spores it contacts. Ozone is generated on-site, eliminating the need to store toxic and corrosive chemicals. The corona discharge method is the most efficient way to produce large amounts of ozone. 3 - O O 3 Chemical Formula for Corona Discharge Ozone ClearWater Tech manufactures high output corona discharge systems capable of producing enough ozone to substantially reduce the consumption of other chemical disinfectants. This reduction will make the water crystal clear and rainwater soft while allowing for cost savings on chemicals and maintenance. Also, important health advantages will be realized, including no hair discoloration, excessive skin dryness, faded swimming apparel, or irritation to the eyes, nasal passages and throat. Ozone reacts to water-borne contaminants significantly faster than other disinfectants and the primary byproduct is pure oxygen. ClearWater Tech ozone systems are built with the finest components available. All are air cooled and use a venturi injection system to create the best possible contact and mixing of ozone while maintaining a high level of safety. In contrast to ultraviolet ozone generators, corona discharge systems produce a much higher concentration of ozone and in much larger quantities. In addition, the annual expense of replacing lamps and checking ballasts is unnecessary with corona discharge systems. Corona discharge ozone generation is the most economical and effective method to use on large, commercial water applications. Ozone Generator The ozone generator houses the ozone reaction chamber, power supply and all electrical components directly related to the production of ozone. Ozone is produced when the feed gas is exposed to a high voltage electrical current inside the reaction chamber. Air Preparation The ClearWater Tech M-15/AD & CD15/AD ozone system is equipped with a heat regenerative desiccant air dryer built into the same enclosure. Corona discharge ozone generators are much more effective, produce more ozone and require far less maintenance if an air preparation unit is included. The air preparation system lowers the dew point of the feed gas. Moist feed gas (air) will cause nitric acid to form inside the generator which decreases ozone production and if not removed, causes corrosion and eventual failure of the generatorʼs internal components. The ability of the ozone generator to produce ozone is drastically reduced as the dew point rises above -55 C. The air dryer desiccant material has an average life expectancy of five years under normal use. Injector Manifold The ozone gas is injected into the filtered water return line by means of the injector manifold. This allows the ozone to be injected into the water under a vacuum condition, which is the safest technology available. Contact Column (optional upgrade) To maximize the effectiveness of ozone, it must be thoroughly mixed and have adequate time to react with the contaminants in the water before returning to the pool. The contact column is designed to achieve this necessary mixing and contact time. Booster Pump (optional upgrade) It is the booster pump that creates the side stream ozone injection loop. Without this pump, the main circulation pump could be overburdened, slowing the filtered water return and decreasing the turnover rate. The booster pump operates all the ozone mixing/injection equipment and enhances the turnover rate. We recommend the use of a booster pump with systems having a marginal flow rate.
4 INSTALLATION UNCRATING & INSPECTION All equipment should be thoroughly inspected immediately upon delivery. If any damage is noticed, promptly notify the freight line and request an on-site inspection. Thoroughly inspect all packing materials prior to discarding. Inspect all plumbing fittings and tubing for packing material inadvertently lodged in any openings. The ClearWater Tech corona discharge ozone system consists of three main components: Ozone Generator Air Preparation Venturi Injector Manifold The optional equipment which can be used with the ozone generator on larger installations includes: Contact Column Booster Pump ORP Controller MOUNTING Select a location for the ozone equipment that is as close as possible to the ozone injection point. Arrange the components in a manner suitable for convenient electrical access. The M-15/AD & CD15/AD enclosures are not rain proof, so it is important to choose a location that will keep the system away from direct weather and excessive heat. Four mounting holes are located on the back of the ozone generator for convenient wall mounting. Mounting hardware is not provided. PLUMBING There are two basic installation methods for the M-15/AD and CD15/AD systems: Full Flow, where the ozone is injected directly into the main water return flow, and Side Stream, which requires a booster pump on a new, separate side stream plumbed off of the main water return line. The side stream plumbing is dedicated to the ozone system only. Follow the instructions below for the alternative you will be using: Full Flow Injector Manifold Plumbing Connections Refer to the ʻFull Flow Installationʼ diagram and follow the instructions below if the ozone is being injected directly into the full flow of the poolʼs return line: 1. Tap into the return line after the pump, filter and heater. The ozone injection point should be the last component in line and as far as possible from the bromine injection point. 2. Glue in the proper injector, noting the direction of flow (indicated by an arrow on the injector). 3. Once the injector is installed, the vacuum may be adjusted as described in the ozone operation section. Note: The ozone generator will only energize for 15 seconds or until a vacuum is attained. Tubing Installation Install the check valve assembly into the injector. Connect the 1/4 Teflon tubing from the OZONE OUT fitting on the bottom of the ozone generator to the check valve assembly on the injector. Secure by tightening the fitting around the 1/4 Teflon tubing after insertion.
5 ELECTRICAL CD15/AD ELECTRICAL CONNECTIONS IMPORTANT: The CD15/AD is capable of accepting input from 120 or 240 AC 50/60 Hz. Located on the bottom of the chassis is a voltage selection switch Be sure the switch is in the correct position for the input voltage. The CD15/AD must have a CONSTANT power source. The air dryer is designed to be ON at all times. An external loop is designed into the CD15/ADʼs electronics to control the ozone portion of the unit. All applicable electrical codes must be observed. The CD15/AD will accept any power cord with an IEC plug on one end. It is available with different electrical cords to suit the differing electrical voltages in different nations. The cords available from ClearWater Tech (and their corresponding part numbers and sample nations) are: CRD900 CRD905 CRD910 CRD915 CRD920 IEC by NEMA 5-15P Plug (USA) IEC by CEE 7/7 Plug (continental Europe) IEC by BS 1363/A Plug (Great Britain, Hong Kong, and Singapore) IEC by AS Plug (Australia and New Zealand) IEC by ASEV 1011 Type 12 Plug (Switzerland) Plug the IEC end of the cord into the CD15/AD unit and the other plug end into a standard wall socket to supply power to the unit. IMPORTANT: The power source selected must be continuously energized. The air dryer portion of the CD15/AD unit must have continuous power in order to supply properly prepared air to the ozone generator. The CD15/AD has three modes of control: 4-20 ma Manual External Loop The 4-20 ma Control wil vary the Ozone output based on signal from any device sending out 4-20 ma. To use this feature switch the 3-way switch to the 4-20 position. Using the pre-wired 3 pin amp, connect wire from this terminal to the external device. Be sure to note the positive (+) and negative (-) positions. Manual The manual mode position will override both the 4-20 and the external loop positions. The Ozone output will automatically go the full output and leave the automatic features disabled. External Control Loop Electrical Connections If the CD15/AD is to be used with an external control source (such as an ORP controller, flow switch, pressure switch, pump, or timer), wire the control source signal to the external control dry contact plug on the bottom of the CD15/AD unit as shown in the illustration below. A single pole single throw (SPST) normally open relay should be used. A single pole double throw (SPDT) can be used if desired. Be sure to use the correct relay coil voltage based on the signal voltage (i.e. 24V, 120V, 240V). CWT manufactures several interface devices designed to electrically couple the CD15/AD with an external control signal. Manual Variable Control The Ozone output of the CD15/AD can be manually adjusted with the control switch in the external loop position, assuming the dry contact is closed.
6
7 OPERATION INITIAL START-UP AND CALIBRATION After the installation has been completed, the water system operating parameters should remain the same as before installation of the ozone generator. The air preparation system on the ClearWater Tech M-15/AD & CD15/AD is a vacuum type and will require adjustment of the air flow through the system. There are two different methods for achieving proper air flow, both involving an SCFH (Standard Cubic Feet per Hour) gauge. (Note: An SCFH gauge is NOT supplied with either unit.) A gauge can be purchased from CWT for the particular unit. Adjusting Air Flow Through the Injector Use an SCFH gauge to accurately measure the amount of flow through the ozone delivery line on a single speed injector. Follow the directions and illustration below and on the following page to optimize flow through the injector: 1. Install the tube fitting into the upper hole on the back side of the SCFH gauge. 2. With the circulation pump running, disconnect the tubing from the ozone outlet of the ozone generator and connect the tubing to the fitting on the gauge. 3. While holding the gauge vertically, read the amount indicated on the gauge. The optimum flow is 15 SCFH. Note: Do not obstruct the bottom air hole on the gauge. 4. The injector has a ball valve to adjust the amount of flow. To adjust the SCFH, simply install the gauge as above and open the ball valve completely. With the pump running, begin closing the gate valve until the optimum flow is achieved on the SCFH gauge. Once the proper flow is achieved, remove the SCFH gauge and reconnect the ozone supply tubing to the fitting on the injector. SCFH Settings Model Venturi SCFH Operating SCFH Vacuum M-15/AD or 20 to 25 5 to 15-1 to -5 CD15/AD
8 Operation Procedures continued Adjusting Air Flow with the Flowmeter Kit (Optional - order Part # GAG440) The other method of adjusting the flow is to add the optional Flowmeter Kit. This consists of an SCFH gauge and tubing which is installed permanently on either the M-15/AD or the CD15/AD, fitting into the external air preparation access loop fittings. To install this flowmeter option, follow the directions and illustration below: 1. Loosen the hose clamps and remove the braided tubing between the two brass external loop elbow fittings. The tubing may be cut with a knife to remove, if necessary. Keep the hose clamps and discard the tubing. 2. The brass elbow fitting next to the ozone check valve will remain, but remove the other brass external loop elbow fitting nearer the end of the unit. Using Teflon tape on the threads, install the brass straight barb fitting into the bulkhead fitting from which the elbow fitting was removed. (See illustration below.) 3. Slide one hose clamp onto each piece of braided tubing on the SCFH gauge. Push the SCFH gauge assembly up into the brass external air preparation access loop barb fittings and tighten the hose clamps. 4. The injector has a ball valve to adjust the amount of flow. Open the ball valve completely. With the pump running, begin closing the gate valve until the optimum flow (15 SCFH) is achieved on the SCFH gauge. Once the proper setting has been achieved, it can be maintained by checking this gauge and adjusting the ball valve as needed.
9 Ozone Systems... Maintenance & Trouble Shooting Manual Parts & Warranty CD15/AD & M15AD Corona Discharge Ozone Generator
10 MAINTENANCE FILTER CARE Ozone will keep the pool much cleaner than any other type of water purification system. This is due to the fact that ozone neutralizes body oils and soaps. After ozone kills the bacteria, the by-products of the process are oxygen, carbon dioxide and filterable solids. Since filterable solids are usually at higher levels than with conventional disinfection processes, the filter will have more work to do. Keeping the filter clean will make a noticeable difference in the clarity of the water. It is recommended that a regular filter cleaning schedule is established, or poor water flow through the filter will result. This will have a direct effect on the amount of ozone that enters the water. OZONE GENERATOR A word of caution: There is extremely high voltage inside the ozone generator. If you suspect a problem, disconnect the power to the unit at the service disconnect box or main electrical panel and immediately contact your ClearWater Tech distributor. Inspect the ozone delivery line check valves daily for water seepage and replace the injector check valve yearly. Clean the ozone generator cabinet air filter: This filter must be cleaned regularly. Depending on the location of the unit, it may be necessary to clean the air filter monthly. The filter element is located on the bottom of the cabinet (see illustration below). This is the air intake element for the cooling fan and may therefore require the most frequent cleaning. The element may be cleaned with soap and water and should be dried completely before reinstalling. Note: In a clean environment, this procedure may only need to be performed every three months. IMPORTANT: CLEAN THIS FILTER REGULARLY! FAILURE TO DO SO WILL PROMOTE OVERHEATING AND WILL VOID THE WARRANTY! Fan Cabinet Bottom Plate Fingerguard Fan Filter Element (Pt # FA40) Fan Filter Grill (snaps on and off)
11 Check valves: Two Kynar check valves are built into the ozone delivery system: one where the ozone tubing attaches to the ozone generator and one where it attaches to the injector. The purpose of these check valves is to prevent water from backing up into the ozone generator. The Teflon ozone delivery line(s) should be inspected daily to insure water is not flowing back into the ozone generator. Check valves should be replaced yearly. Note: The only time it is possible for water to flow back toward the ozone generator is during a system shutdown. Always inspect for water seepage during this time. Dielectric tube: The dielectric tube is located in the reaction chamber of the ozone generator. This tube should be inspected periodically and cleaned if necessary. Once each year, remove the reaction chamber and inspect the dielectric tube for debris. If the tube is cracked, the dielectric tube must be inspected and cleaned. A cracked dielectric should be replaced. Please consult your ClearWater Tech distributor, as the improper installation of the dielectric may cause safety problems! Since the air that is introduced into the reaction chambers is high quality, the dielectric tube should remain clean for at least one year before inspection is required. Removal of the Dielectric Tubes 1. Disconnect all the power to the system, including panel breakers, service disconnect box and main circulation pump interlock. 2. Unplug the electrical terminal on the back of the drive module, disconnect the polypropylene barbed air fitting and the Kynar ozone fitting. 3. Remove the ozone reaction chamber from the back plate. 4. Disconnect the high voltage wire from the coil. Remove the stainless steel nut and Kynar center rod from the center of the reaction chamber. 5. The Teflon end caps can now be gently removed by slowly pulling straight out. The glass dielectric will remain attached to one of the end caps. 6. If the dielectric tube is dirty, clean the glass with Isopropyl alcohol. Do not use a solvent that will leave an oily residue. 7. Clean the inside of the stainless steel reaction chamber with a wire brush as necessary, then wipe with Isopropyl alcohol. 8. Be sure all solvents have evaporated prior to reassembly. Re-Installation of the Dielectric Tube 1. Inspect the O-rings and replace as necessary. 2. Tighten the end caps so that they are approximately 1/8 from the aluminum extrusion. 3. Replace the reaction chamber and connect the air and ozone lines. 4. Connect the high voltage wire to the coil. 5. Readjust the system as necessary (see operating instructions). Annual maintenance agreements are available from ClearWater Tech. Maintenance continued
12 MAINTENANCE SCHEDULE For All ClearWater Tech, LLC. Corona Discharge Ozone Generators Monthly Service: 1. Clean the Ozone generator cabinet air filters: These filters must be cleaned regularly. Failure to do so will promote overheating and will void the warranty. Depending on the location of the unit, it may be necessary to clean the air filters more often. On the bottom of the cabinet are the air filter elements. These are air intake elements for the cooling fans and may therefore require the most frequent cleaning. All elements may be cleaned with soap and water. Dry completely before reinstalling. 2. Inspect check valves and ozone delivery line: There are two check valves in the ozone delivery line. The purpose of these check valves is to prevent water from backing up into the ozone generator. The Teflon ozone delivery line should be inspected often to ensure water is not flowing back into the ozone generator. During a system shutdown, it is possible for water to flow back toward the ozone generator. Always inspect for water seepage during this time. Note: there is no such thing as a 100% check valve. ClearWater Tech, LLC. recommends that a vacuum break beinstalled with all units operating on dried air feed. Please contact your ClearWater Tech, LLC. distributor for more information about our vacuum break. 3. Inspect desiccant indicator: The indicator serves several functions. The first function is to cool the heated air from the dryer chambers, than it will absorb any remaining moisture and last it will act as indicator for the customer. If the silica has changed from BLUE to PINK (or white) this is an indication of severe humid environments or possible water back flow. Yearly Services: 1. Replace the cooling fan filters. Failure to do so will promote over heating. 2. Replace the air inlet particulate filter on the ozone generator. This filter prevents small particulates from entering the reaction chamber. It must be replaced annually to prevent clogging. 3. Replace all check valves. There is no such thing as a 100% check valve. Yearly replacement can prevent many of the back flow problems. All stainless steel check valves should be rebuilt. Along with yearly check valve replacement, ClearWater Tech, LLC. recommends that a vacuum break be installed with all units operating on dried air feed. Please contact your ClearWater Tech, LLC. distributor for more information about our vacuum break. 4. Clean glass dielectric and reaction chamber(s). Wipe clean both the outside of the dielectric and the inside of the stainless steel reaction chamber with isopropyl alcohol. Be very careful! Scratches in the conformal coating may damage the dielectric upon reassembly. Do not use any solvents that will leave an oily residue. Disassemble, clean, and assemble reaction chambers as specifically described in the ClearWater Tech, LLC. owners manual. If there are scratches in the conformal coating, nitric acid build up, or cracks in the dielectric contact your ClearWater Tech, LLC. distributor for further service.
13 Maintenance schedule continued Replace the desiccants. On all AD-40 air dryers and ozone generators with built in air dryers, replace both the heating desiccant and external indicating desiccant yearly. ClearWater Tech, LLC. air dryers are designed to be on 24 hours a day. Failure to do so will allow moist air to be introduced into the reaction chamber. Improperly dried feed air will cause nitric acid formation and premature dielectric failure. Every Three Years: 1. Replace all cooling fans in the ozone generator. Failure to do so will promote overheating. 2. Hone and rebuild reaction chambers. In addition to cleaning the dielectric, the reaction chamber should be honed. A honing tool is available through ClearWater Tech, LLC. distributors. The reaction chamber should be cleaned as instructed in the owners manual. The glass dielectric should be replaced. Any scratches, imperfections in the conformal coating, or chipping in the glass itself can cause serious damage to the ozone generator. The reaction chamber should be rebuilt using new O-rings to ensure a proper seal. Care should be taken to ensure that the dielectric does not get damaged during this process. General Notes: All service should be performed by ClearWater Tech, LLC. factory trained personnel. Ozone generators producing concentrations of more than 1% require specific ozone resistant materials to be used. The owners manual specifies materials that meet these standards. All replacement parts can be ordered through ClearWater Tech, LLC. distributors. Failure to use materials that do not meet these standards or repairs done by non-factory trained personnel will void all warranties.
14 OZONE GENERATOR TROUBLE SHOOTING PROBLEM/SYMPTOM POSSIBLE CAUSE SOLUTION Unit does not turn on No power to unit Check breakers Switch not turned on Blown fuse Not enough vacuum Incorrect wiring connections Check switch Replace fuse on bottom panel Close the injector bypass valve Check wiring (see manual) Unit does not stay on Unit overheating Clean fan filter, check fan Insufficient vacuum (should be -5 to -15 on SCFH gauge) Defective check valve Adjust injector vacuum, be sure check valves are properly installed Inspect and replace if necessary Ozone cycles on and off Overheating Clean fan filter, check fan Defective power Check for constant power if not timer controlled Individual drive indicator No power to drive module Check drive module (see illustration) lights not on Blown fuse Replace fuse Drive module burnt out Replace drive module Unit trips circuit breaker Incorrect wiring Check wiring (see manual) Incorrect circuit breaker Check and, if necessary, replace with correct circuit breaker You receive an electrical shock upon touching the unit Incorrect wiring Check wiring (see manual) Unit not grounded Ground unit in accordance with local codes Unit has been flooded Return unit for major service or completely disassemble and clean Water in unit or Insufficient vacuum Adjust injector vacuum ozone delivery tubing Defective check valve(s) Replace check valve(s) Excessive back pressure on check valve Back pressure not to exceed 40 psi - if over 40 psi consult ClearWater Tech distributor Ozone smell present Insufficient vacuum Adjust injector vacuum Loose internal fittings Defective O-ring seals in reaction chamber Defective dielectrics Defective reaction chamber Inspect and tighten fittings Check and replace if necessary Check and replace if necessary Check and replace if necessary You suspect that no ozone Drive module failure Touch the bottom of the coil - is being produced replace if it is not warm Dielectric failure Inspect and replace if necessary
15 TROUBLE SHOOTING PROBLEM/SYMPTOM POSSIBLE CAUSE SOLUTION Unit seems noisy Not properly secured to wall/floor Bolt it firmly into place Shipping damage Fan blocked Locate and repair Check and clear obstructions Flow meter will not adjust Air preparation not operating Make sure air prep package is set properly Defective check valve Check and replace AIR DRYER TROUBLESHOOTING PROBLEM/SYMPTOM POSSIBLE CAUSE SOLUTION Air dryer not operating No power to air dryer Check power connections Switch not on Fuse blown Insufficient vacuum Turn switch on Replace fuse Adjust injector vacuum Air dryer cold when operating No power to air dryer Check power connections and breakers Switch not on Fuse blown Defective heater cartridge Turn switch on Replace fuse Replace heater cartridge Desiccant indicator cartridge Air leak Tighten fittings not blue in color Desiccant saturated in storage Reactivate desiccant (as described in manual) Air dryer not cycling Timer defective Replace timer Relay defective Defective vacuum gauge Loose Kynar compression fittings Replace relay Replace vacuum gauge Tighten all Kynar fittings
16 PART LIST FOR M-15/AD & CD15-AD CKV21 Check valve CD 1/4 kynar - FPT, low pressure FA40 Fan - Cooling, CD filter element only - 4 FA41 Fan - Cooling, CD 120V 50/60 Hz - 4 FA42 Fan - Cooling, CD 240V 50/60 Hz - 4 FA43 Fan - Cooling, CD external finger guard - 4 FA44 Fan - Cooling, CD internal finger guard - 4 FLT34 Filter - inline particulate 1/4, for one to three cell CD systems RCC6 Complete CD reaction chamber, 2 RCC70 Dielectric only, all CD reaction chamber, 2 RCC80 High voltage lead, all 2 CD reaction chambers RCC103 High voltage end cap with O-Rings RCC108 Non-high voltage end cap with O-Rings ORS30 O-Ring Package DRM10 Drive Module - M-1500/CD Complete, with HV transformer and mounting bracket DRM12 Drive Module - M-1500/CD HO Complete, with HV transformer and mounting bracket HVT100 H.V. coil only for 2 C.D. reaction chamber HWS2012 Mounting screws for reation chamber FTK325 Fitting, Kynar elbow for reation chamber FUS20 Fuse - CD, 5 Amp, slow blow PS150 PS155 PS160 PS165 PS300 PS305 DES12 DES16 SV200 TM15 ADP20 ADP22 SWT90 ASP128 Power supply watt for a single CD cell (M-1500), 100V-120V, 50/60 Hz Power supply watt for a single CD cell (M-1500), 208V-240V, 50/60 Hz Power supply watt for a single CD cell (M-15/AD), 100V-120V, 50/60 Hz Power supply watt for a single CD cell (M-15/AD), 208V-240V, 50/60 Hz Power supply watt for one to three CD cells, 100V-120V, 50/60 Hz Power supply watt for one to three CD cells, 208V-240V, 50/60 Hz Desiccant, AD-40 heating chamber recharge, nonindicating Desiccant, indicating chamber recharge, 1lb Solenoid - 3 Way Valve for air dryer w/o fittings,120v 50/60 Hz Timer Solid State for the dryer 2 cube AD-40, part - Heating Element, 120V AD-40, part - Heating Element, 240V Switch - interlock box vacuum Maintenance Kit for M-15/AD & CD15/AD
17 M15/AD OZONE GENERATOR DIMENSIONS AND LAYOUT Front and Bottom Views
18 M-15/AD OZONE GENERATOR COMPONENTS M-15/AD SPECIFICATIONS: Energy Required (120 VAC models): V min., 125 V max., 50/60 Hz, 2.5 Amps, 300 Watts Energy Required (240 VAC models) V min., 240 V max., 50/60 Hz, 1.25 Amp, 300 Watts Dimensions: H x W x 5.5 D Shipping Weight: Lbs.
19 CD15/AD OZONE GENERATOR DIMENSIONS AND LAYOUT Front and Bottom Views
20 CD15/AD OZONE GENERATOR COMPONENTS CD15/AD SPECIFICATIONS: Energy Required (120 VAC models): V min., 125 V max., 50/60 Hz, 3.0 Amps, 360 Watts Energy Required (240 VAC models) V min., 240 V max., 50/60 Hz, 1.5 Amp, 360 Watts Dimensions: H x W x 5.5 D Shipping Weight: Lbs.
21 EXPLODED VIEW OF CORONA DISCHARGE REACTION CHAMBER
22 POWER SUPPLY FOR M-15/AD Testing Voltage to the Drive Module
23 POWER SUPPLY FOR CD15/AD Testing Voltage to the Drive Module Power Supply for Single Cell Units (120/240V Pt# PS170)
24 ClearWater Tech, LLC Limited One-Year Warranty Summary of the Warranty ClearWater Tech, LLC ( CWT ) makes every effort to assure that its products meet high quality and durability standards and warrants the products it manufactures against defects in materials and workmanship for a period of one (1) year, commencing on the date of original shipment from CWT, with the following exceptions: 1) The warranty period shall begin on the installation date if the installation is performed within 90 days of the original shipment from CWT; 2) The warranty period shall begin on the date of the bill of sale to the end user if the installation date is more 90 days after the original shipment date. To validate the warranty, a warranty card, accompanied by a copy of the bill of sale, must be returned to CWT and must include the following information: End user name Complete address, including telephone number Date installed Complete model and serial number information Name of company from which the unit was purchased Repairs and replac. Items Excluded from the Warranty This warra damaged or rendered defective as a result of: an accident, misuse, alteration or abuse an act of God such as flood, earthquake, hurricane, lightning or other disaster resulting only from the forces of nature normal wear and tear operation outside the usage parameters stated in the product userʼs manual check valve/solenoid valve failure use of parts not sold by CWT damage which may occur during shipping service or unit modification not authorized by CWT failure to meet service requirements as outlined in the I & O manual Obtaining Service Under the Warranty Any product and/or part not performing satisfactorily may be returned to CWT for evaluation. A Return Goods Authorization (RGA) number must first be obtained by either calling or writing your local authorized dealer, distributor or CWT direct, prior to shipping the product. The problem experienced with the product and/or part must be clearly described. The RGA number must appear prominently on the exterior of the shipped box(es). The prod original is not available. You are responsible for paying shipping charges to CWT and for any damages to the product and/or part that may occur du If, after the product and/or part is returned prepaid and evaluated by CWT, it proves to be defective while under warranty, CWT will, at its election except for shipments going outside the 50 states of the United States of America. If upon inspection, it is determined that there is no defect or that the damage to the product and/or part resulted from causes not within the scope of this limited warranty, then you must bear the cost of repair or replacement of damaged product and/or part and all return freight charges. Any unauthorized attempt by the end user to repair CWT manufactured product direct at (805) , extension 23. Exclusive Warranty There is no other expressed warranty on CWT products and/or parts. Neither this warranty, or any other warranty, expressed or implied, including any implied warranties or merchantability of fitness, shall extend beyond the warranty period. Some states do not allow limitations on how long an implied warranty lasts, so that the above limitation or exclusion may not apply to you. Disclaimer of Incidental and Consequential Damages No responsibility such a defect. Some st not apply to you. Legal Remedies of Purchaser This warranty gives you specific legal rights and you may also have other rights which vary from state to state. THIS STATEMENT OF WARRANTY SUPERSEDES ALL OTHERS PROVIDED TO YOU AT ANY PRIOR TIME. ClearWater Tech, LLC. 850 Capitolio Way Suite E, San Luis Obispo, California (805) Fax: (805)
T E C H, L L C. Ozone Systems. Ozone System. CD-20/O2 Corona Discharge Ozone Generator. Installation & Owner s Manual
T E C H, L L C. Ozone Systems Ozone System CD-20/O2 Corona Discharge Ozone Generator Installation & Owner s Manual P.O. BOX 15330, San Luis Obispo, CA 93406 Copyright 1994 - ClearWater Tech, Inc. Reproduction
More informationIMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INSTRUCTIONS 2 1. Read and Follow All Instructions 2. Read this manual completely before attempting installation. 3. All permanent electrical connections should be made by a qualified
More informationOZONE SYSTEM FOR IN-GROUND POOLS New and Existing
INSTALLATION & OPERATIONS MANUAL FOR Z0-910/912 OZONE SYSTEM FOR IN-GROUND POOLS New and Existing MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0454-041900/03 IMPORTANT SAFETY
More informationElectrical Field. Molecular weight: 48. Color: Solubility: Ozone leaves no telltale taste or odor.
O 3 Introduction... This Installation and Operation Manual is written to assist in the installation, operation and maintenance of ozone delivery systems manufactured by RK2 Systems Inc. The equipment has
More informationOwner s Manual PCS PRO
Owner s Manual PCS PRO Designed and Manufactured Exclusively by Ozotech, Inc. M43-31017 REV A Table of Contents 1.0 Limited Warranty 3 2.0 Service Returns 4 3.0 Caution 5 4.0 Theory of Operation 5 4.1
More informationEcoMaster - Residential Pools up to 40,000 Gallons
- Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water Copyright 2013 Prozone Water Products: 3004 11 th Ave. -
More informationAir Preparation System
Theory of Operation/Product Description (continued) THEORY OF OPERATION/PRODUCT DESCRIPTION CHAPTER 1 RK2 Systems ozones are designed for safe, effective use in a variety of water treatment applications.
More informationPZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series
PZ2 Series Manual PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems INSTALLATION GUIDE and OPERATION MANUAL Prozone PZ2 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.
More informationMCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA
MCD Corona Discharge Ozone Generators MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 4-0622 Copyright 2005 DEL Ozone, Inc. IMPORTANT SAFETY INSTRUCTIONS When installing and using DEL Models
More informationAir Preparation System
Theory of Operation/Product Description (continued) THEORY OF OPERATION/PRODUCT DESCRIPTION CHAPTER 1 RK2 Systems ozones are designed for safe, effective use in a variety of water treatment applications.
More informationMixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50
INSTALLATION MANUAL for MDV Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50 MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0635
More informationNext Generation Corona Discharge Installation & Operation Manual
Next Generation Corona Discharge Installation & Operation Manual 4-2319-01 Rev.A IMPORTANT SAFETY INSTRUCTIONS READ & FOLLOW ALL INSTRUCTIONS Read this manual completely before attempting installation.
More informationOzone Systems. Installation & Operation Manual POE10 POE12. Corona Discharge Ozone Generators. ClearWater Tech, LLC. Integrated Ozone Systems
Ozone Systems Installation & Operation Manual POE10 POE12 Corona Discharge Ozone Generators ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax:
More informationWarnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5
TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance
More informationWarnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6
TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4-5 Replacement Element Installation 5 Replacement Parts 5-6 Heater Coverage Areas 6 General Notes 6
More informationOzone + UV Sanitation
Ozone + UV Sanitation Installation Manual 4-2177-01 Rev.C IMPORTANT SAFETY INSTRUCTIONS When installing and operating the DEL Spa Solar Eclipse, basic precautions should always be followed: READ AND FOLLOW
More informationRK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02
35-3000RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: 71-0071RK Revision: P1 Released: 7/18/02 RKI Instruments Inc. 1855 Whipple Road Hayward, CA 94544 PH: 800-754-5165 Fax: 510-441-5650
More informationOzone Generator Systems
PZ2-1 & PZ2-2 - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal
More information1, 2, & 4. Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL. DEL Ozone SAN LUIS OBISPO, CA USA Fax:
1, 2, & 4 Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL DEL Ozone SAN LUIS OBISPO, CA 93401 USA 800-676-1335 Fax: 805-541-8459 111904 / 4-0308 Rev. F Table of Contents SECTION 1 General
More informationOZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS
INSTALLATION & OPERATIONS MANUAL FOR ZO-900 OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS MANUFACTURED BY 3428 Bullock Lane San Luis Obispo, CA 93401 800-676-1335 4-0449 Rev. A.- 052605 Copyright
More informationINSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER
INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS IMPORTANT INFORMATION Warnings 2 Installation Instructions 3 Wiring Instructions 3 Outdoor
More informationWKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe
More informationCELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler
CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationEcoMaster - Residential Pools up to 40,000 Gallons
- Residential Pools up to 40,000 Gallons INSTALLATION/ OPERATION GUIDE Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear Water PROZONE Copyright 2018 Prozone Water Products: 3004 11 th
More informationDR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR
DR Series HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR Model: DR-10 Installation & Operations Manual 451 Black Forest Road, Hull, Iowa, 51239 712.439.6880 info@ozonesolutions.com www.ozonesolutions.com
More informationIndustrial Vacuums, Inc
Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances
More informationPZ1, PZ3 & PZ6 Installation Guide
PZ1, PZ3 & PZ6 Installation Guide PROZONE INTERNATIONAL, INC. Ozone Water Purification Systems INSTALLATION GUIDE Prozone PZ1, PZ3 and PZ6 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.
More informationRK-02 Multi Point Detector Operator s Manual
65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationGetz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System
Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED
More informationOzone Generator Systems
PZ2-4V - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal Clear
More informationOzomax Ltd Ozone generators
Ozomax Ltd Page - 1 Ozomax Ltd Ozone generators OZONATORS VTTL series OZO 1VTTL to OZO 50 VTTL General specifications / installation and maintenance instructions Ozomax would like to congratulate you on
More informationTG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator
TG-10 Wall Mount Installation and Operation Manual High Output Ozone Generator Ozone Solutions 451 Black Forest Road Hull, IA 51239 Phone: (712) 439-6889 Fax: (712) 439-6733 2 Table of Contents Safety
More informationXaact Spot. Xaact Hot Spot
Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............
More informationRK/ RK Oxygen Detector Operator s Manual
65-2494RK/65-2497RK Oxygen Detector Operator s Manual Part Number: 71-0179RK Revision: 0 Released: 2/16/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.
More informationVSA Series Air Dryer. User s Guide
VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud
More informationVMUS-4 Ozone Generator
VMUS-4 Ozone Generator Installation and Operation Manual pg. 1 Cautions, Warnings and Hazards Refer to the manual of the ozone generating system first, to assure proper location of all ozone equipment.
More informationHI Industrial Utility Heater HI Soleus Air International
HI1-50-03 Industrial Utility Heater HI1-50-03 2010 Soleus Air International Thank you for choosing a Soleus Air Utility Heater. This owner s manual will provide you with valuable information necessary
More informationALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
More informationINSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER
INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions
More informationCarbon Dioxide Sample-Draw Detector Operator s Manual
35-3001-05-03 Carbon Dioxide Sample-Draw Detector Operator s Manual Part Number: 71-0413 Revision: 0 Released: 8/4/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationCT-7 Series Toxic Gas Transmitter Operator s Manual
65-2341 CT-7 Series Toxic Gas Transmitter Operator s Manual Part Number: 71-0424 Revision: P1 Released: 6/8/17 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction
More informationRK/ RK Carbon Monoxide Detector Operator s Manual
65-2496RK/65-2499RK Carbon Monoxide Detector Operator s Manual Part Number: 71-0156RK Revision: 0 Released: 2/16/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationSPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax
SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts
More informationNext Generation Corona Discharge Auto Voltage Sensing Installation Manual
Next Generation Corona Discharge Auto Voltage Sensing Installation Manual 4-2122-01 Rev.B IMPORTANT SAFETY INSTRUCTIONS When installing and operating the Spa Eclipse ozone generator, basic precautions
More informationREAD AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 IMPORTANT SAFETY INSTRUCTIONS Read the instructions The appliance is not to be used by persons (including children) with reduced physical, sensory
More informationPRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR
Installation and Operating Instructions FLOW AUTOMATIC REGULATOR SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS WARNING Risk of Electric Shock. Connect only to a branch circuit protected by a ground-fault
More informationRK-05 Carbon Monoxide Detector Operator s Manual
65-2433RK-05 Carbon Monoxide Detector Operator s Manual Part Number: 71-0189RK Revision: 0 Released: 5/17/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationDRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual
DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through
More informationIW-25-2 Dehumidifier Installation & Operations. Manual
IW-25-2 Dehumidifier Installation & Operations Installation and Operation Manual Manual IW-25-1 Dehumidifier Please Read and Save These Instructions Please Read and Save These Instructions Innovative Dehumidifier
More informationOPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS
OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS CAUTION RISK OF INJURY! READ MANUAL BEFORE OPERATING! This manual is an important part of the Corona Discharge Ozone Generator and must remain
More informationREAD AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE
XAACT Xtract 200 INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00018 Rev B 032912 1 CONTENTS: Machine Specifications............ 2 Record Important
More informationModel CWA200 Owner s Manual
Model CWA200 Owner s Manual ClearWaveAir Purifier Owner s Manual Model CWA200 Thank you for purchasing the ClearWaveAir air purifier. The ClearWaveAir system will greatly improve the air quality in your
More informationDEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL
DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL C-M-P.COM 4-2535-01 Rev.B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS WARNING: Risk of electric shock. Install at least 5 feet from
More informationIMpORTANT SAFETy INSTRUcTIONS
Table of contents SAFETy SETUp OpERATION MAINTENANcE Safety... 2 Specifications... 4 Setup... 4 Operation... 6 WARNING SyMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Diagram... 10 Warranty...
More information4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL
4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL THE 4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL ENGLISH 01 RELIABLE. RIGHT THERE WITH YOU. At Reliable, we do what we love, and take pride
More informationInstallation and Operation Manual. ACF-18 Automatic Chlorinating Feeder
Installation and Operation Manual ACF-18 Automatic Chlorinating Feeder Operating Specifications Inlet Flow: 1.0-1.5 gpm Outlet Flow: = Inlet Flow Inlet Pressure: 10-45 psi Maximum Output: 26 lbs. of Available
More informationOzone Systems. Installation & Operation Manual CD15nx CD30nx. Corona Discharge Ozone Generators. ClearWater Tech, LLC. Integrated Ozone Systems
Ozone Systems Installation & Operation Manual CD15nx CD30nx Corona Discharge Ozone Generators ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724
More informationA2Z Ozone, Inc. PRODUCT MANUAL
A2Z Ozone, Inc. PRODUCT MANUAL INSTALLATION & OPERATION MANUAL CE www.a2zozone.com Rev. 02142018 CONTENTS Page Important Safety Instructions... Specifications... Installation Instructions... 3 4 5 Troubleshooting...
More informationClear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual
Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual IMPORTANT SAFETY INSTRUCTIONS For Further Assistance Contact Us: 303.872.4477 support@clearcomfort.com
More informationCombustible Gas Sample-Draw Detector Operator s Manual
35-3001-01 Combustible Gas Sample-Draw Detector Operator s Manual Part Number: 71-0282RK Revision: A Released: 8/3/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationOperation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ
Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ CS6-50-VD Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up of COOL-SPACE
More informationFOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.
FOR THE RECORD You should record the model and serial numbers, which can be found on the back of the unit, for future reference. Warranty: 18 mo. on unit and 1 year on check valve assembly Model: The Ozone
More informationInstallation and Operating Instructions
Installation and Operating Instructions WaterQuick Pro II Advanced - Hot Water Circulation Pump WaterQuick Pro II Advanced Step 1. Choose the appropriate place to install the pump and Flow Monitor: WaterQuick
More informationTurbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.
OWNER S MANUAL Model EP600 120V., 60Hz., 7.5 Amps. Turbo Stick Vac For information or assistance: EURO-PRO Operating LLC 94 Main Mill Street, Door 16 Plattsburgh, NY 12901 Tel.: 1 866 98SHARK (74275) www.sharkvac.com
More informationNilfisk Model VHS255 Drum Top Vacuum
Instructions/Spare Parts Manual Nilfisk Model VHS255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in classified (hazardous) environments, as serious injury could result. Under
More informationPUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650
USER GUIDE PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650 AB0039 FOR RESIDENTIAL USE ONLY!! BROAN-NUTONE LLC; HARTFORD, WISCONSIN WWW.NUTONE.COM 1-888-336-3948 REGISTER YOUR PRODUCT ONLINE
More informationSpa Control System OWNER S MANUAL
LIMITED WARRANTY ONE YEAR LIMITED WARRANTY: UNITED SPAS, INC. warrants, to the original purchaser, the Spa Equipment against defects in materials or workmanship for a period of one year from date of purchase.
More informationUser Manual. 40 Tower Fan MODEL: WFTR40W
User Manual 40 Tower Fan MODEL: WFTR40W 1. READ these instructions carefully before installing and operating the appliance. Keep them for further reference. 2. Record in the space below the SERIAL/MODEL
More informationMDH Series Air Dryer. User s Guide
MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS
More informationWhynter Portable Ice Maker 33 lb capacity - White
Whynter Portable Ice Maker 33 lb capacity - White Model # : IMC-330WS INSTRUCTION MANUAL Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully
More informationInstructIon Manual KrEs EQuIPMEnt stands
Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available
More informationModel: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE
Ambassador 20 Automatic Carpet Scrubber Model: C8420-115 C8420-240 OPERATION SERVICE PARTS CARE This manual is furnished with each new Minuteman Ambassador 20. This provides the necessary operating and
More informationST. KITTS CEILING FAN
ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,
More informationOperation and Maintenance Manual 120V/60HZ
Operation and Maintenance Manual 120V/60HZ GLACIER CS5-16-VD CS5-16-VD-TB CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Operation & Maintenance Manual 60HZ Models Table of Contents:
More informationOWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:
OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,
More informationOperation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ
Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up
More informationINSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier
Remember to register your air purifier at: www.surroundair.com/register/ INSTRUCTION MANUAL Multi-Tech 8500 Air Purifier HEPA Activated Carbon Germ-Killing UV Lamp Photocatalytic Oxidation Ionizer Toll
More informationRK Multi Point Detector Operator s Manual
65-2480RK Multi Point Detector Operator s Manual Part Number: 71-0198RK Revision: C Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before
More informationB.I.C.A Built-In Coffee Appliance
B.I.C.A Built-In Coffee Appliance Automatic Coffee Brewer Parts & Service Models: 1033510, 1033510S & 1033511 3828 S. Main St. Los Angeles, CA 90037-1491 800-421-6860 310-787-5444 Fax 310-787-5412 e-mail:
More informationInstallation, Operation & Service Manual
Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and
More informationEBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD60 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the CD60 dehumidifier is a rugged, industrial unit which utilizes
More informationMAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.
Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase
More informationWhole House Filter Model: WH-LD
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Save manual for future reference Whole House Filter Model: WH-LD! WARNING Please read carefully before proceeding with installation. Your failure to follow
More information20 High velocity Air
20 High velocity Air Circulator 66878 Set up and Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
More informationNext Generation Corona Discharge Next Generation Corona Discharge Nueva generación Corona de descarga
Next Generation Corona Discharge Next Generation Corona Discharge Nueva generación Corona de descarga EC-10, EC-20 & EC-40 Installation Manual Manuel d installation Manual de instalación...1 CANADIEN FRANÇAIS...15
More informationEBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632
More information52 CEILING FAN. Owner s Manual Models #50336, 50337
52 CEILING FAN Owner s Manual Models #50336, 50337 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-706-3267, 9 a.m.- 5 p.m.
More informationAir Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com
Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon
More informationHC Ceramic Tower Heater Operating Instructions HC Soleus Air International
HC7-15-01 Ceramic Tower Heater Operating Instructions 3081955 HC7-15-01 2007 Soleus Air International Thank you for choosing a Soleus Air Ceramic Tower Heater. This owner s manual will provide you with
More informationREAD AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS International Patent #9,938,166 Patented Micro-Ozone cell ozone technology: Patent #8367007 1 IMPORTANT SAFETY INSTRUCTIONS Read the maintenance
More informationMDV. Mixing Degas Vessel. For Spa Ozone Generators Installation & Operations Manual Rev.C
MDV Mixing Degas Vessel For Spa Ozone Generators Installation & Operations Manual 4-0642 Rev.C Table of Contents SECTION 1 General Information... 1 SECTION 2 Mounting the MDV and GAC Cartridge... 1 SECTION
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350
Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More informationCamarillo 52 Ceiling Fan
Owner s Manual Camarillo 52 Ceiling Fan Part # 269263, 269259, 269287 Model # 32091, 32092, 32087 Exclusively Distributed by: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 2017 Made in China
More informationRK Carbon Monoxide Transmitter Operator s Manual
65-2335RK Carbon Monoxide Transmitter Operator s Manual Part Number: 71-0177RK Revision: 0 Released: 4/12/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationCRV Clean Room Vacuum
CRV Clean Room Vacuum Model: C80704-01, 02 SS (115V) C80704-03, 04 Painted (115V) C80704-07, 12 Painted (240V) C80704-08, 09 SS (240V) OPERATION SERVICE PARTS CARE Revised 7/02 FOR COMMERCIAL USE ONLY
More informationINSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL
INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL TABLE OF CONTENTS PAGE # SAFETY INSTRUCTIONS......... 2 INSTALLATION INSTRUCTIONS................... 3 CABINET LOCATION GUIDELINES...
More informationEBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL KOMPACT OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the Kompact is a rugged, industrial unit, which utilizes
More information2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,
More information