LG COMMERCIAL AIR CONDITIONERS 2007

Size: px
Start display at page:

Download "LG COMMERCIAL AIR CONDITIONERS 2007"

Transcription

1 LG Electronics Air Conditioning Marketing Yoidodong, Youngdungpogu, Yoido P.O.Box 5 Seoul 0, Korea Phone: 8225 Fax: EUCA01 LG Commercial Air Conditioners For continual product development, LG reserves the right to change specifications without notice. LG Electronics Inc. Printed in Korea December 06 LG COMMERCIAL AIR CONDITIONERS 0 Enjoy Clean, Quiet and Comfortable Air Conditioning with LG.

2 LG Electronics, The orld s Best Seller, Seven Years in a Row The outstanding quality of LG air conditioners is recognized by people all over the world. According to an article by Japan s famous freezing and air conditioning magazine JARN (Japan Air Conditioning, & Refrigeration News), LG Electronics sold its 4. million air conditioners in 00, taking the world s first spot in sales. hen the company has posted 10 million units in 04 and 05, the first of its kind, it has become the top seller of air conditioners in the world for seven consecutive years. This landmark achievement has been made possible by our continuous R&D activities, expansion of production lines, and 6sigma campaigns (6sigma quality control system), among others. LG Electronics is committed to maintaining its market leadership in air conditioners through its advanced technologies and R&D efforts. Commercial Air Conditioners 02 03

3 LG Air Conditioners are environmentfriendly and futureoriented. To reduce freon gas, a prime ozone destroyer, they adopt alternative refrigerant, and neo plasma airpurifying system for powerful sterilization for healthconscious customers. Also, ARTCOOL series with outstanding designs have received International Forum Design Award, Reddot Design Award and G Mark. They have improved air flow innovatively to realize world s lowest noise, and provide a more pleasant and convenient indoor environment. Environmental concern 0 As the concern for environment increases day by day, EC Directive made it a regulation to put an indication on all air conditioning products. ith the information regarding energysaving, customers will easily understand products considering the environment. Customers will have to purchase the products considering the energy label to meet their needs. Energy label shows the energy consumption of the unit classified with different colors. Energy Efficiency Class of The Unit In Mode : Energy Efficiency Class of The Unit In Mode : Commercial Commercial Air Air Conditioners Conditioners 04 05

4 LG AIR CONDITIONERS 0 CONTENTS CEILING CASSETTE TYPE CEILING CONCEALED DUCT FLOOR STANDING TYPE 52 CEILING & FLOOR TYPE SYNCHRO ROOFTOP TYPE 56 MULTI SPLIT AIR CONDITIONERS Commercial Air Conditioners 06 0

5 CAC MODEL LINE UP / 45 / 66 Rooftop Ceiling Cassette UTACP NEA UT NEC UTACP NEA UT NEC UTACP NFA UT NFC UTACP NFA UT NFC UT3ACP NDA UT NDC UT42 NDC UTACP NDA UT NDC UTACP NDA UT NDC Ceiling Concealed Duct R0AH SC0 UBAC NHA UB NHC UBAC NHA UB NHC UBAC NHA UB NGC UB3AC NGA UB NGC UB42 NRC UBAC NEA UB NRC UBAC NEA UB NRC B0AH SV0 Ceiling and Floor R0AH SC0 V0AC SE0 V0AH SE0 VAC SE0 UVAC NBA UVAC NBA UVAC NBA UV NEC UV NBC UV NBC UV NBC Ceiling Suspended UV NKC UV42 NLC UV NLC UV NLC R0AH SC0 Only V0AC UE0 VAC ULA UUAC UMA UUAC UEA UUAC UEA UU3AC UEA UUAC UHA UUAC UHA Outdoor Heat Pump DC Inverter 3Phase DC Inverter V0AH UE0 UU ULL UU UEC UU UEC UU UEC UU3 UEC UU UHC UU UHB UU UEC UU UEC UU UEC UU UEC UU UHC UU UYB UU UYB UU2 UYC (.1) UU100 UC () Commercial Air Conditioners UU3 UEC UU43 UHC UU4 UHC UU61 UHC 08 0 Floor Standing P03AH SR1 P05AH UL2 P08AH UE1 (.1)

6 LG AIR CONDITIONERS 0 MPS INVERTER SYSTEM MPS Inverter System. energy saving with MPS Inverter control LG MPS (Multi Power System) inverter is an energy saving airconditioning system which uses either one or two highly efficient constant speed compressors and a DC inverter compressor. 100% Capacity Inverter Load Constant Speed Compress or hat is LG MPS Inverter System? Starting Inverter Fixed Speed Inverter Fixed Speed Fixed Speed Operating Ratio imising LG MPS Inverter MPS is a power saving system with dual compressors of different capacity (% & 40%). Variable load matching is achieved with constant speed & inverter control compressors. Fast pull down & warm up is achieved through MPS and with power reduction as room temperature is reached. + escroll DC Inverter Compressor Load is low : Only Inverter Comp. Load is high : Inverter Comp + Constant Comp Operating NonInverter Conventional (On/Off Operation) During a conventional air conditioning cycle, the compressor must constantly turn on and off in order to maintain the desired temperature setting. A large amount of power is used during the restart resulting in unnecessary energy consumption. Energy saving with MPS inverter control MPS Inverter system operates one cycle with two compressors. hen the load is small, only one compressor completes the cycle at low operation as explained in the diagram below. This results in reduced energy consumption as compared to a conventional inverter system that uses only one large inverter compressor. Power Consumption In case of low Hz Operation Saving Zone 2 Comp. System Low noise & Vibration e Scroll Compressor LG MPS consists of two or more compressors to perform at its best depending on cooling load. hen required, only one compressor will operate resulting in less vibration and noise. Low Vibration and Noise Soft Start Operation Load 1 Comp. System. Capacity Powerful Capacity ith a wide operating range in both heating and cooling modes, inverter air conditioners will cool or heat your room even in extreme outdoor temperature conditions. can be sustained even when the outdoor temperature is 10 C using LG's MPS inverter technology. UT model Indoor Temp( C) 10 1 imum at standard operation Outdoor Temp( C) Comfortable with Fast & Performance hen the air conditioner is initially activated to either heat or cool, the compressor will operate at maximum speed to reach the desired temperature quickly. Once the desired temperature is achieved, unlike conventional air conditioners that turn the compressor on and off, LG inverter units constantly adjust and vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised. Temp Temp Conventional Power INVERTER Power Setting Temp. On On On Off Off Off Time Setting Temp. Time MPS Inverter System escroll DC Compressor Conventional Compressor

7 LG AIR CONDITIONERS 0 CEILING CASSETTE TYPE CEILING CASSETTE TYPE Reducing the symptoms of allergies with less dust and odour. PLASMA Air Purifying System (Optional) LG's unique PLASMA Air Purifying System not only reduces microscopic contaminants and dust, but also filters house mites, pollen and even pet fur to ease allergy and asthma symptoms. ith a filter that can be used over and over again by simply washing it, you can enjoy clean fresh air without having to worry about changing the filter every couple of years or so resulting in cost savings. Function to Control the Air Volume by Ceiling Height Control of the air intensity has been made possible by employing a heightcontrol algorithm for the interior fan. LG"Ceiling Cassette" is a indoor unit which is installed for the significant purpose. The ceiling cassette is used for the commercial purpose. It can be installed in various places such as restaurants, hotels, offices and meeting rooms. This unit has nice outlook and is equipped with many special features. It has four louvers for the air circulation in all directions which in turn can maintain even and wide cooling. Dust particles Polluted Air Odour Ionizer Dust electrode discharge +KV discharge PhotoCatalyst Coated Mesh Odour molecule Purified fresh Air Generating plasma Two Thermistor Control There may be a significant difference between the temperature taken at the installed product and indoor temperature. Two thermistor control provides option to control temperature by referring any of the two temperatures. ith the help of the slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be done. One thermistor is in the Indoor unit & the other one is in the LCD wired remote. Elevation Choice Low Standard Hi Installation on the normalheight ceiling Conditions of Release hen the elevation is low: lower than 2.4m in height Operate the device at one level lower than the standard level hen the elevation is standard: about 2.m in height Operate the device at the standard air flow level hen the elevation is high: higher than m in height Operate the device at one level higher than the standard level installation on the higher ceiling Ceiling Cassette 13

8 LG AIR CONDITIONERS 0 CEILING CASSETTE TYPE Group Control 1) Operation Summary here several products are linked, one specific control device can control a specific number of products. 2) Specific Operation Connecting line is linked to each of the indoor equipments for communication. A specific control device is connected to each of them and this control device can control the same function. Group control function is enabled by cutting an optional jump wire in the wired remote control. At this time, the main system will not respond in order to prevent data collision. hile executing group control command, use the random data(0 3minutes) in the main body of indoor equipment for limiting starting current. Control device can control up to 16 indoor equipments. Long Distance, High Elevation Piping LG air conditioners (cassette and concealed duct models) can be installed for long distance (up to m) and high elevation applications (up to m). Super Low Power Consumption Use in Standby Mode by Adopting SMPS (Switching Mode ) Power waste due to standby power Power is wasted if a plug is connected to an outlet even though the appliance is turned off. Development of super powersaving SMPS (Switching Mode ) Low standby power by reducing 0% of standby power. No need to pull out every plug when system is not in use. Swirl Swing Swirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the louvers. Comparison of temperatures Comparison of Air Flow s 4Open(Conventional) Vane 1 Vane 2 Vane 3 Vane 4 Vane 1 Vane 2 Vane 3 Vane 4 Vane 1 Normal air flow Vertical Temp. Differences Open Open Open Open Time Swirl Swing (New) Close Open Close Open Time Open Close Open Close Vane 2 Vane 4 Close Open Close Open Swirl Swing(pleasant air) Horizontal Temp. Differences Open Close Open Close Vane 3 Close Open Close Open Space Control The vane angle can be set in two positions to give optimum indoor comfort. It can be controlled by wired remote control to eliminate direct drafts which can lead to discomfort and reduced productivity. ~0 High Ceiling Operation Depending on the height of the installation, LG air conditioners allow you to vary the speed of the indoor fan motor. hen installation is low, the RPM can be reduced, but it can also be increased when the installation is high to ensure optimum comfort levels. The speed can be adjusted via the slide switch on the back of the LCD wired remote. Auto Changeover ith reverse cycle models, the air conditioner will switch automatically from cooling to heating modes depending on the set temperature. Initial Setting Temp: C: (Memory the final setting temp) Control of setting temp. ired Remoted Controller:~ C Reset Button in indoor unit: finally memorized temp. ireless Remoted Controller: 23~2 Temp +2 InsideTemp Setting Temp COMP ON off ON off ndoor FAN Setting Low Setting Low Cycle off Stop ON Setting off ON Low stop Setting off Low stop Cassette Cover (Option) Maintains the ceiling elegance. ON off Setting Low :PTDCD1 Covers the side area of cassette. Gives elegant looks. Light weight. Suitable when false ceiling is unavailable. eekly Program The operator can set an On/Off reservation of the air conditioner for a period of one week. LCD ired Remote Controller Hour ON/ OFF Timer in 1 hour intervals TEST RUN Mode SelfDiagnosis function 3Step Fan Speed selection Operation Indication Room Temperature Display Only mm thick Option ireless Remote controller Optimal Air Distribution Optimal air distribution with 4way directional Air flow system. 4way Auto Swing % % % % Ceiling Cassette 14

9 CEILING CASSETTE TYPE COOLING ONLY CEILING CASSETTE TYPE HEAT PUMP UTACP / UTACP / UTACP UT3ACP / UTACP / UTACP UT / UT / UT / UT UT / UT / UT Plasma Air Purifying System Anti Corrosion Gold Fin(Outdoor) eekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) Child Lock Function EasytoClean Air Filter Two Thermistor Control Optimal Air Distribution Auto Operation Plasma Air Purifying System Anti Corrosion Gold Fin(Outdoor) eekly Program Turbo Fan High Head Drain Pump Auto Changeover Low Standby Power Auto Restart Central Controller(Accessory) Child Lock Function EasytoClean Air Filter Two Thermistor Control Optimal Air Distribution PLASMA Group Controller Long & High Piping PLASMA Group Controller Long & High Piping Indoor Unit _ F/Panel Capacity r Input Running Current A Ø,V, Hz E.E.R / r Setting Temperature Range(Indoor) C Operational Temperature Range(Outdoor) C Air Flow Rate Indoor(H/M/L) CMM(CFM) Noise Level(SoundPress,1m) Indoor(H/M/L) db(a)± 3 I/h Dimensions Indoor (*H*D) Panel Net eight Indoor kg(lbs) Stuffing Quantity ithout S/Parts /40ft Outdoor Unit _ Compressor Refrigerant Charge Charge g(oz) Outdoor Fan Discharge Side/Top Noise Level(SoundPress,1m) Outdoor db(a)± 3 Pipe Connection Liquid Dimensions (*H*D) Outdoor Net eight Outdoor kg(lbs) Cable (Includes earth) No.*mm2 Connecting Cable (Includes earth) No.*mm2. Piping Length/Elevation m Ø,V, Hz Stuffing Quantity ithout S/Parts /40ft UTACP NEA PTCEA1, CEC1,0 5,422 1,840 1, 20, ~ 5~43 /14/13(5/44/45) 43/41/ x22.4x (xx26) 26.4x26.4x1.2 (xx) 1() / UUAC UMA 1,000 (3) R410a 1 / 4 (5) 5 / 8 (.88).1x2x10.8 (840x55x) 44() 3 * 4 * 0.5 / 1,20, 6/4 UTACP NFA PTCFA, CFC,000,034 2, , 20,.8 ~ 5~43 /14/13(5/44/45) 43/41/ 2.3x2.3x11.5 (44x44x22) 3x3x1. (8x8x) 26() 84/168 UUAC UEA 1,0 (42.4) R410a 55 1 / 4 (5) 5 / 8 (.88) 3x.8x.6 (80x655x3) 5() 3 * 4 * 0.5 / 1,20, 81/11 UTACP NFA PTCFA, CFC,0 8,2 2, , 20, 10. ~ 5~43 1/1/(61/0/5) 45/42/3 2.3x2.3x11.5 (44x44x22) 3x3x1. (8x8x) 26() 84/168 UUAC UEA 2,000 (0.6) R410a 1 / 4 (5) 5 / 8 (.88) 3x.5x.6 (80x800x3) (1.2) 3 * 3 * 0.5 / 1,20, /114 UT3ACP NDA PTCDA1, CDC1,000 10,5 3, 6.4 1, 20, 3.6 ~ 5~43 /23/(883/8/42) 40// 3x3x11.3 (840x840x8) xx1.2 (xx) (2.) 2/144 UU3AC UEA Scroll 2,100(4.1) 52 1 / 4 (5) 5 / 8 (.88) 3x41.x.6 (80xx3) 85(.3) 5 * 4 * 1. / 3,04, 51/111 UTACP NDA PTCDA1, CDC1 14,06 5,0.3 1, 20, 5.05 ~ 5~43 //26(105/88/) 43/41/3 3x3x11.3 (840x840x8) xx1.2 (xx) (2.) 2/144 UUAC UHA Scroll 3,00(1) 56 3 / 8 (.52) 3 / 4 (1.05) 3x4x1 (00xx) 3 (5.0) 5 * 4 * 1. / 3,04, 2/55 UTACP NDA PTCDA1, CDC1,000,826 6, , 20, ~ 5~43 34//(00/11/105) /4/43 3x3x11.3 (840x840x8) xx1.2 (xx) (2.) 2/144 UUAC UHA Scroll 4,00(.8) 58 1 / 2 (.) 3 / 4 (1.05) 3x4x1 (00xx) 3 (5.0) 5 * 4 * 1. / 3,04, 2/55 Indoor Unit _ F/Panel Capacity Input Running Current / A Ø,V, Hz E.E.R / C.O.P / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level (Sound Press,1m) H/M/L db(a)±3 I/h Dimensions (*H*D) Indoor Units Outdoor Unit _ Decoration Panel Net eight Indoor Units kg(lbs) Decoration Panel kg(lbs) Stuffing Quantity ith out S/Parts /40ft UT NEC PTCEA1, CEC1,000 3,51 13,0 3,86 1,3 1, 5/ 1,2~0, 1 2 ~ 5~43 ~.5/8/(3/3/) / / xx22.4 (x26x) 26.4x1.2x26.4 (xx) 1(41.) 3(6.6) / UU ULC UT NEC PTCEA1, CEC1,000 5, 1,800 5,803 1,880 2,0 8.3/8. 1,2~0, 1 2 ~ 5~43 ~ 13//11(45/4/8) 41/3/ xx22.4 (x26x) 26.4x1.2x26.4 (xx) 1(41.) 3(6.6) / UU UEC Compressor Refrigerant Charge Charge g(oz) 1,0(42.4) 1,0(45.0) Fan Discharge Side/Top Noise Level Sound Press,1m db(a)± Dimensions *H*D.3x.3x.6 3x.8x.6 (0x0x5) (80x655x3) Net eight Outdoor kg(lbs) (68.3) 52(11) Pipe connection Liquid 3/8 (.52) 1/2 (.) Cable(Includes earth) No.*mm2 3* 3* Interunit Cable(Includes earth) No.*mm2 4*0.5 4*0.5. Piping Length/Elevation m /10 / 1,20, 1,20, Stuffing Quantity ithout S/Parts /40ft 144/3 81/11 UT NFC PTHFA, PTHFC,000,034 26,400,3 2,0 2, 10.8/11.2 1,2~0, 1 1 ~ 5~43 ~ /14/13(523/44/45) 43/41/ x11.5x2.3 (44x22x44) 3x1.2x3 (8xx8) (52.) 3(6.6) 84/168 UU UEC 1,(68.) 52 3x.5x.6 (80x800x3) (1.2) 1/2 (.) 3* 4*0.5 / 1,20, /114 UT NFC PTHFA, PTHFC,000 8,2,000,62 3,0 4,0.8/1 1,2~0, ~ 5~43 ~ 1/1/(61/0/5) 45/42/3 2.3x11.5x2.3 (44x22x44) 3x1.2x3 (8xx8) (52.) 3(6.6) 84/168 UU UEC 2,0(81.3) 53 3x.5x.6 (80x800x3) 64(141) 5/8 (.88) 3* 4*0.5 / 1,20, /114 UT NDC PTCDA1, CDC1,000 10,551 3,0 11,6 4,0 3,6.8/. 1,2~0, 1 1 ~ 5~43 ~ /23/(883/8/42) 40//.1x11.3x.1 (840x8x840) x1.2x (xx) (0.4) 5(11) 2/144 UU3 UEC 2,0(2.1) 52 3x41.x.6 (80x10x3) 80(16) 5/8 (.88) 3* 4*0.5 / 3,04, 51/111 UT NDC PTCDA1, CDC1 14,068 52,800,45 5,840 5,0 10.0/.5 1,2~0, ~ 5~43 ~ //26(105/88/) 43/41/3.1x11.3x.1 (840x8x840) x1.2x (xx) (0.4) 5(11) 2/144 UU UHC 3,0 (116.4) 5 3x4x14.5 (00x1165x) 105(2) 3/8 (.52) 3/4 (1.05) 3* 4*0.5 / 3,04, 2/55 UT NDC PTCDA1, CDC1 16,413 61,0,0 6,8 6,10 1/10. 1,2~0, ~ 5~43 ~ 34//(00/11/105) /4/43.1x11.3x.1 (840x8x840) x1.2x (xx) (0.4) 5(11) 2/144 UU UHB SCROLL 4,00(1) 5 3x4x14.5 (00x1165x) 3(5) 3/8 (.52) 3/4 (1.05) 3* 4*0.5 / 3,04, 2/55 Ceiling Cassette 16 1 UUAC UUAC UUAC UU3AC UUAC / UUAC UU UU UU/UU UU UU / UU

10 CEILING CASSETTE TYPE DC INVERTER CEILING CASSETTE TYPE 3PHASE DC INVERTER UT / UT / UT / UT UT / UT / UT UT / UT42 UT / UT Plasma Air Purifying System Anti Corrosion Gold Fin(Outdoor) eekly Program Turbo Fan High Head Drain Pump Auto Changeover Low Standby Power Auto Restart Central Controller(Accessory) Child Lock Function EasytoClean Air Filter Two Thermistor Control Optimal Air Distribution Plasma Air Purifying System Anti Corrosion Gold Fin(Outdoor) eekly Program Turbo Fan High Head Drain Pump Auto Changeover Low Standby Power Auto Restart Central Controller(Accessory) Child Lock Function EasytoClean Air Filter Two Thermistor Control Optimal Air Distribution PLASMA Group Controller Long & High Piping PLASMA Group Controller Long & High Piping Indoor Unit _ F/Panel Capacity (~~) Input (~~) Running Current / A EER / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level (SoundPress,1m) H/M/L db(a)±3 I/h Dimensions (*H*D) Indoor Units Decoration Panel Net eight Indoor Units kg(lbs) Decoration Panel kg(lbs) Stuffing Quantity ithout S/Parts /40ft Outdoor Unit _ UT NEC PTCEA1, CEC1 4,0~,000~16,000 1,3~3,51~4,688 4,800~13,800~,000 1,40~4,044~5, 0~1,00~1,4 4~1,100~1,3 1.6 ~/2.0 ~ 1,20, 8 ~ 10~43 ~.5/8/(3/3/) / / xx22.4 (x26x) 26.4x1.2x26.4 (xx) 1(41.) 3(6.6) / UU UEC UT NEC PTCEA1, CEC1 6,840~,000~,0 2,006~5,~6,,14~,0~,840 2,261~5,4~,0 623~1,640~2, 62~1,6~2, ~.5/~10.6 1,20, 2 1 ~ 10~43 ~ 13//11(45/4/8) 41/3/ xx22.4 (x26x) 26.4x1.2 x26.4 (xx) 1(41.) 3(6.6) / UU UEC Compressor(Inverter) escroll escroll Compressor(Constant) Refrigerant Charge Charge g(oz) 1,100(40) 1,0(52.1) Fan Discharge Side/Top Noise Level Sound Press,1m db(a)±3 51/45 51/45 Pipe Connection Liquid 3/8 (.52) 1/2 (.) Dimensions xhxd 3x.8x.6 3x.8x.6 (80x655x3) (80x655x3) Net eight Outdoor kg(lbs) 46(101) 52(1) Cable(Includes earth) No.*mm2 3* 3* Interunit Cable(Includes earth) No.*mm2 4*0.5 4*0.5. Piping Length/Elevation m /10 40/ Ø,V, Hz 1,20, 1,20, Stuffing Quantity ithout S/Parts /40ft 81/11 81/11 UT NFC PTHFA, PTHFC,0~,000~,800 2,61~,034~8,440 10,8~2,0~,000 3,04~8,08~, 8~2,10~2,0 840~2,0~3,00 ~1/4.5~13. 1,20, 1 6 ~ 10~43 ~ /14/13(523/44/45) 43/41/3 2.3x11.5x2.3 (44x22x44) 3x1.2 x3 (8xx8) (52.) 3(6.6) 84/168 UU UEC escroll 1,(61.2) 52/46 1/2 (.) 3x.5x.6 (80x800x3) 6(2) 3* 4*0.5 / 1,20, /114 UT NFC PTHFA, PTHFC 10,640~,000~,0 3,0~8,5~,84,2~,0~,640 3,58~,43~11,3 6~2,5~2,80 88~2,0~4,0 5.~1/~1. 1,20, 2 3 ~ 10~43 ~ 1/1/(61/0/5) 45/42/3 2.3x11.5x2.3 (44x22x44) 3x1.2x3 (8xx8) (52.) 3(6.6) 84/168 UU UEC escroll 2,100() /46 5/8 (.88) 3x41.x.6 (80x10x3) 80(16) 3* 4*0.5 / 1,20, 51/111 UT NDC PTCDA1, CDC1 13,680~,000~ 4,0~10,~14,06,~41,400~53,000 4,58~,1~,5 1,6~3,0~4,800 1,26~3,340~5,100 6.~./.6~23.1 1,20, 2 3 ~ 10~43 ~ /23/(883/8/42) 40//.1x11.3x.1 (840x8x840) x1.2x (xx) (0.4) 5(11) 2/144 UU UHC escroll 3,0(5) 58/ 5/8 (.88) 3x4x14.5 (00x1165x) 105(2) 3*5.0 4*0.5 / 1,20, 2/55 UT NDC PTCDA1, CDC1,65~~55,0 5,468~14,06~16,,455~55,0~63,0 6,8~16,~,4 2,5~4,88~5,0 2,~5,044~5,00 ~26.6/8.6~2.3 1,20, 0 ~ 10~43 ~ //26(105/88/) 43/41/3.1x11.3x.1 (840x8x840) x1.2x (xx) (0.4) 5(11) 2/144 UU UYB escroll,100(0.4) Top Discharge 5/56 3/8 (.52) 3/4 (1.05).xx2.1 (806x1,x) 142(3) 3*5.0 4*1. 0/ 1,20, /42 UT NDC PTCDA1, CDC1,66~~64,400 6,3~16,4~,84,0~61,0~0,840,3~,0~,61 2,566~5,8~6,0 2,10~6,613~,4.3~.3/~3 1,20, ~ 10~43 ~ 34//(00/11/105) /4/43.1x11.3x.1 (840x8x840) x1.2x (xx) (0.4) 5(11) 2/144 UU UYB escroll,100(0.4) Top Discharge 5/56 3/8 (.52) 3/4 (1.05).xx2.1 (806x1,x) 1(6) 3*5.0 4*1. 0/ 1,20, /42 Indoor Unit _ F/Panel Capacity (~~) Input (~~) Running Current / A EER / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level (SoundPress,1m) db(a)±3 I/h Dimensions (*H*D) Indoor Units Decoration Panel Net eight Indoor Units kg(lbs) Decoration Panel kg(lbs) Stuffing Quantity ith S/Parts /40ft Outdoor Unit _ UT NDC PTCDA1, CDC1,0~,0~3,000 6,0~,8~10,8 2,0~,000~41,000 8,6~11,140~,0 1,~2,0~3, 2,3~3,010~3,4 / 8 ~ 5~43 ~ 1,20, /23/(883/8/42) 40//.1x11.3x.1(840x8x840) x1.2x(xx) (0.4) 5(11) 2/144 UU3 UEC 3,0/4, Compressor Twin Refrigerant Charge Charge g(oz) 2,0 (8) Fan Discharge Side/Top Noise Level Sound Press, 1m db(a) ±3 51 Pipe Connection Liquid 5/8 (.88) Dimensions *H*D 3x41.x.6(80x3x1,0) Net eight Outdoor kg(lbs) 80 Cable(Includes earth) No.*mm2 5* Interunit Cable(Includes earth) No.*mm2 4*0.5. Piping Length/Elevation m / Stuffing Quantity ithout S/Parts /40ft 51/111 UT42 NDC PTCDA1, CDC1,0~42,000~46,0,~,3~13,5,0~4,000~51,00 8,~13,80~,1 2,100~3,0~3,8 2,040~3,400~3,40 / 2 2 ~ 5~43 ~ 1,20, 2/26/23(10//8) 42/40/ 5.0.1x11.3x.1(840x8x840) x1.2x(xx) (0.4) 5(11) 2/144 UU43 UHC 3,0/4, Twin 4,000 (141.1) 53 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1,165x) 5 5* 4*1. 5/ 2/55 UT NDC PTCDA1, CDC1,100~~52,0 8,0~14,080~,340,800~51,0~,000,340~,100~,840 2,110~4,~4,00 2,00~3,~4,0.0/ ~ 5~43 ~ 1,20, //26(105/88/) 43/41/3.1x11.3x.1(840x8x840) x1.2x(xx) (0.4) 5(11) 2/144 UU4 UHC 3,0/4, Twin 4,000 (141.1) 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1,165x) 5 5* 4*1. 5/ 2/55 UT NDC PTCDA1, CDC1,000~,000~55,000 8,800~14,6~16,1,0~~61,0,8~16,4~,0 2,6~4,410~4,8 2,6~4,~4, /.1 2 ~ 5~43 ~ 1,20, 34//(00/11/105) /4/43.1x11.3x.1(840x8x840) x1.2x(xx) (0.4) 5(11) 2/144 UU61 UHC 3,0/4, Twin 4,000 (141.1) 55 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1,165x) 5 5* 4*1. 5/ 2/55 Ceiling Cassette 1 UU UU UU UU UU UU/UU UU3 UU43/UU4/UU61

11 On Off On Off On Off LG AIR CONDITIONERS 0 CEILING CONCEALED DUCT TYPE CEILING CONCEALED DUCT TYPE Hidden in the ceiling, this product is suitable for applications that require floor level or individual level air conditioning for buildings where there are many rooms or halls, such as restaurants, concert halls and hotels. Installation is not hindered by the location of lighting fixtures or room structure, and interior renovation is made easy with the installation of various ventilation diffusers. E.S.P: External Static Pressure Always air volume and sound kept as design regardless of E.S.P change using this technology, you can Optimize Duct work Installation Keep Capacity & Sound level as desired Simplify model numbers The Phase control motor Technology gives benefit of saving money to Installer. Desired Air flowrate is obtained by controlling the phase of motor while installing the product and this makes your duct work system flexible. *E.S.P is easily controlled by remote controller. Quiet Operation & Easy Service Innovative Design for blower and Housing system Low Noise! Light eight! Easy Service Plastic Blower and Housing Designed for Low noise Designed to reduce eight. Designed for Easy service with separated Housing. This product will guarantee you lower sound level and less service expenses. Supply Duct Return Duct Central Controller Operation Summary LG units come with advanced control options, take for instance the Central Controller. Designed for the commercial application, where multiple Air Conditioning units have been installed. You can control or fault find up to 16~ Air Conditioning units (via 8 separate controllers) individually or all together. Ceiling Concealed Duct Air flow rate at 2mmAq Air flow rate at 10mmAq Controller #1 Controller #2 Controller #8 External static pressure(mmaq)

12 LG AIR CONDITIONERS 0 CEILING CONCEALED DUCT TYPE LARGE CAPACITY TYPE (BIC DUCT) Zone Controller This feature can be used to control the operation of the Air Conditioning Unit where each zone (maximum of 4 zones) has a separate thermostat and damper motor, your Air Conditioning Specialist can advise you if you require a VAV (Variable Air Volume) Installation in your home / office, as well as providing a quotation for Installation (including the supply of thermostats and damper motors). Zone Control sub PCB ABZCA ROOM1 Thermostat Damper Motor Damper Motor ROOM3 Thermostat ROOM2 Thermostat Damper Motor Damper Motor ROOM4 Thermostat High Head Drain Pump Auxiliary Drain Pump automatically drains water. A standard drainhead height of up to 00mm is possible, creating the ideal solution for perfect water drainage. 00mm Drain Pipe Slope (1/~1/100) 0mm Fixture 4mm Flexible Drain Hose eekly Program The operator can set an On/Off reservation of the air conditioner for a period of one week. LCD ired Remote Controller Hour ON/ OFF Timer in 1 hour intervals TEST RUN Mode SelfDiagnosis function 3Step Fan Speed selection Operation Indication Room Temperature Display Only mm thick Drain pipe Two Thermistor Control There may be a significant difference between the temperature taken at the installed product and indoor temperature. Two thermistor control provides option to control temperature by referring any of the two temperatures. ith the help of the slide switch at the back of the LCD wired remote controller, selection of the desired thermistor for controlling the unit can be done. One thermistor is in the Indoor unit & the other one is in the LCD wired remote. Long Distance, High Elevation Piping Our LG Air Conditioners(Cassette and Concealed duct model) are possible to be installed a long distance( m) that is included High Elevation(m) Air flow rate 5dB Conventional 53dB New External static pressure (mmaq) An invertible fan motor has been installed. The air volume can be controlled by the wired remote controller (0~mmAq) Less Noise The product has considerably less noise level inside resulting from changing to the directdrive method from the preestablished pulley method of the blower and the motor. Conventional NE Pulley Direct Drive Convenience in Installation(convertible flow) You can adjust the air flow either vertically or horizontally depending on the characteristics of the space where it's installed. Horizontal Flow Convenience in Installation (ESP control facilitated) You can always control the air flow rate with the wired remote controller regardless of the ESP. Conventional NE ired Remocon High Efficiency The device, which has high efficiency/less noise due to the Variable technology used, can be run by motorgenerated electricity. Ceiling Concealed Duct Option ireless Remote controller Vertical Flow High efficiency, less noise, low energy intake, fresh air intake An invertible fan motor has been installed. The air volume can be controlled by the wired remote controller.(0~mmaq)

13 CEILING CONCEALED DUCT TYPE COOLING ONLY CEILING CONCEALED DUCT TYPE HEAT PUMP UBAC / UBAC / UBAC UB3AC / UBACP / UBAC UB / UB / UB UB / UB / UB eekly Program Two Thermistor Control Group Control Hour ON/OFF Child Lock Function Auto Restart Anti Corrosion Gold Fin(Outdoor) Zone Control(Accessory) Central controller(accessory) eekly Program Auto Changeover Two Thermistor Control Group Control Hour ON/OFF Child Lock Function Auto Restart Hot Start (Heat pump ) Anti Corrosion Gold Fin(Outdoor) Zone Control(Accessory) Central controller(accessory) Indoor Unit _ Capacity Input Running Current A E.E.R / r Setting Temperature Range(Indoor) C Operational Temperature Range(Outdoor) C Air Flow Rate Indoor(H/M/L) CMM(CFM) External Static Pressure mmaq Noise Level(SoundPress,1m) Indoor(H/M/L) db(a)±3 I/h Dimensions (*H*D) Indoor Net eight Indoor kg(lbs) Stuffing Quantity ithout S/Parts /40ft Outdoor Unit _ Compressor Refrigerant Charge Charge g(oz) Outdoor Fan Discharge Side/Top Noise Level (SoundPress,1m) Outdoor db(a)±3 Pipe Connection Liquid Dimensions (*H*D) Outdoor Net eight Outdoor kg(lbs) Cable(Includes earth) No.*mm2 Connecting Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout S/Parts /40ft UBAC NHA,0 5,422 1, , 20, 5.4 ~ 5~43 1/14.5/13(583/5/45) 8 /34/ 2.0 3x10.2x1. (880x2x4) (61.) 0/2 UUAC UMA 1,000(3) 1 / 4 (5) 5 / 8 (.88).1*2*10.8 (840*55*) 44() 3 * 4 * 0.5 / 1,20, 6/4 UBAC NHA,000,034 2, , 20,.80 ~ 5~43 /1/14(6/583/44) 8 3// 3x10.2x1. (880x2x4) (61.) 0/2 UUAC UEA 1,0(42.4) 55 1 / 4 (5) 5 / 8 (.88) 3*.8*.6 (80*655*3) 5() 3 * 4 * 0.5 / 1,20, 81/11 UBAC NGA,000 8,2 2, 1 1, 20, ~ 5~43 2/23/(/8/06) 10 42/40/ 46.4x11.x1.1 (10xx4) (8) 5/11 UUAC UEA 2,000(0.6) 1 / 4 (5) 5 / 8 (.88) 3*.5*.6 (80*800*3) (1.2) 3 * 3 * 0.5 / 1,20, /114 UB3AC NGA,000 10,5 3, 1, 20,. ~ 5~43 /2/2 (11/10/) 10 42/40/ 46.4x11. x1.1 (10xx4) (8) 5/11 UU3AC UEA Scroll 2,100(4.1) 52 1 / 4 (5) 5 / 8 (.88) 3*41.*.6 (80*1,0*3) 85(.3) 5 * 4 * 1. / 3,04, 51/111 UBACP NEA 14,06 5,80. 1, 20, ~ 5~43 40//(1413/1/105) 44/42/40 43x14.5x26. (xx680) 68(14.) 5/0 UUAC UHA Scroll 3,00(1) 56 3 / 8 (.52) 3 / 4 (1.05) 3*4*1 (00**) 3 (5.0) 5 * 4 * 1. / 3,04, 2/55 UBAC NEA 58,000 1,000,0.0 1, 20, ~ 5~43 4/45/40/(1/8/1413/) 4/46/44/42 43x14.5x26. (xx680) 0() 5/0 UUAC UHA Scroll 4,00(.8) 58 1 / 2 (.) 3 / 4 (1.05) 3*4*1 (00**) 3 (5.0) 5 * 4 * 1. / 3,04, 2/55 Indoor Unit _ Nominal Capacity (~~) Nominal Input (~~) Running Current / A EER / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) External Static Pressure mmaq Noise Level(Sound Press, 1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Stuffing Quantity ithout S/Parts /40ft Outdoor Unit _ UB NHC,000 5, 1,800 5,803 1,880 2,0 8.3/8. 1,2~0, 1 2 ~ 5~43 ~ 1/14.5/13(583/5/45) 8 /34/ 2.0 3x10.2x1. (880x2x4) (.2) 0/2 UB NHC,000,034 26,400,3 2,0 2, 10.8/11.2 1,2~0, 1 1 ~ 5~43 ~ /1/14(6/583/44) 8 //34 3x10.2x1. (880x2x4) (.2) 0/2 UU UEC UU UEC Compressor Refrigerant Charge Charge g(oz) 10(45.0) 0(68.) Fan Discharge Side/Top Noise Level Sound Press, 1m db(a)± Pipe Connection Liquid 1/2 (.) 1/2 (.) Dimensions xhxd 3x.8x.6 3x.5x.6 (80x655x3) (80x800x3) Net eight Outdoor kg(lbs) 52(11) (1.2) Cable(Includes earth) No.*mm2 3* 3* Interunit Cable(Includes earth) No.*mm2 4*0.5 4*0.5. Piping Length/Elevation m / / 1,20, 1,20, Stuffing Quantity ithout S/Parts /40ft 81/11 /114 UB NGC,000,3,0 10, 4,0 3,.8/1 1,2~0, 2. 1 ~ 5~43 ~ 2/23/(/8/06) 10 40// 4x11.x1. (10xx4) (84) 5/11 UU UEC (81.3) 53 5/8 (.88) 3x.5x.6 (80x800x3) 64(141) 3* 4*0.5 / 1,20, /114 UB NGC,000 10,551 3,0 11,6 4,0 4,1.8/. 3,0~4, 1 1 ~ 5~43 ~ /2/26(11/10/) 10 42/3/ 4x11.x1. (10xx4) (84) 5/11 UU3 UEC 20(2.1) 52 5/8 (.88) 3x41.x.6 (80x10x3) 80(16) 3* 4*0.5 / 3,04, 51/111 UB NRC 14,068 52,800,45 5,840 5,0 10.0/.5 3,0~4, ~ 5~43 ~ 40//(1413//105) 44/42/40 6 4x.0x2 (x0x) (1) 5/0 UU UHC 40(14) for m 5 3/8 (.52) 3/4 (1.05) 3x4x14.5 (00x1165x) 105(2) 3* 4*0.5 / 3,04, 2/55 UB NRC 16,413 61,0,0 6,8 6,4 1/10. 3,0~4, ~ 5~43 ~ /45/40(166/1413/) 46/44/42 4x.0x2 (x0x) (1) 5/0 UU UHB SCROLL 400(1) for m 5 3/8 (.52) 3/4 (1.05) 3x4x14.5 (00x1165x) 3(5) 3* 4*0.5 / 3,04, 2/55 Ceiling Concealed Duct UUAC UUAC UUAC UU3AC UUAC / UUAC UU UU/UU UU UU / UU

14 CEILING CONCEALED DUCT TYPE DC INVERTER CEILING CONCEALED DUCT TYPE 3PHASE DC INVERTER UB / UB / UB UB / UB / UB UB / UB42 UB / UB eekly Program Auto Changeover Two Thermistor Control Group Control Hour ON/OFF Child Lock Function Auto Restart Hot Start (Heat pump ) Anti Corrosion Gold Fin(Outdoor) Zone Control(Accessory) Central controller(accessory) eekly Program Auto Changeover Two Thermistor Control Group Control Hour ON/OFF Child Lock Function Auto Restart Hot Start (Heat pump ) Anti Corrosion Gold Fin(Outdoor) Zone Control(Accessory) Central controller(accessory) Indoor Unit _ Capacity (~~) Input (~~) E.E.R / C.O.P / Running Current / A Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) External Static Pressure mmaq Noise Level(SoundPress,1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Stuffing Quantity ithout S/Parts /40ft Outdoor Unit _ Compressor(Inverter) Compressor(Constant) Refrigerant Charge Charge g(oz) Fan Discharge Side/Top Noise Level Sound Press, 1m db(a)±3 Pipe Connection Liquid Dimensions xhxd Net eight Outdoor kg(lbs) Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout S/Parts /40ft UB NHC 6,840~,000~,0 2,006~5,~6,,14~,0~,840 2,261~5,4~,0 623~1,640~2, 62~1,6~2, ~.5/~10.6 1,2~0, ~ 10~43 ~ 1/14.5/13(583/5/45) 8 /34/ 2.0 3x10.2x1. (880x2x4) (.2) 0/2 UU UEC escroll 00(52.1) 51/45 1/2 (.) 3*.8*.6 (80*655*3) 52(1) 3* 4*0.5 40/ 1,20, 81/11 UB NHC,0~,000~,800 2,61~,034~8,440 10,8~2,0~,000 3,04~8,08~, 8~2,10~2,0 840~2,0~3, ~1/4.5~13. 1,2~0, ~ 10~43 ~ /1/14(6/583/44) 8 //34 3x10.2x1. (880x2x4) (.2) 0/2 UU UEC escroll 0(61.2) 52/46 1/2 (.) 3*.5*.6 (80*800*3) 6(2) 3* 4*0.5 / 1,20, /114 UB NGC 11,400~,000~,000 3,340~8,1~10, 13,110~34,0~41,400 3,8~10,110~,1 1,03~2,~2,80 1,064~2,800~4, ~1/~1. 1,2~0, ~ 10~43 ~ 2/23/(/8/06) 10 40// 4x11.x1. (10xx4) (84) 5/11 UU UEC escroll 00() /46 5/8 (.88) 3*41.*.6 (80*10*3) 80(16) 3* 4*0.5 / 1,20, 51/111 UB NGC 13,680~,000~ 4,0~10,~14,06,~41,400~53,000 4,58~,1~,5 1,6~3,0~4,800 1,26~3,340~5, ~./.6~23.1 1,2~0, ~ 10~43 ~ /2/26(11/10/) 10 42/3/ 4x11.x1. (10xx4) (84) 5/11 UU UHC escroll 30(5) 58/ 5/8 (.88) 3*4*14.5 (00*1165*) 105(2) 3*5.0 4*0.5 / 1,20, 2/55 UB NRC,65~~55,0 5,468~14,06~16,,455~55,0~63,0 6,8~16,~,4 2,5~4,88~5,0 2,~5,044~5,00 0 ~26.6/8.6~2.3 1,2~0, ~ 10~43 ~ 40//(1413//105) 44/42/40 6 4x.0x2 (x0x) (1) 5/0 UU UYB escroll 100(0.4) Top Discharge 5/56 3/8 (.52) 3/4 (1.05).**2.1 (806*1,*) 142(3) 3*5.0 4*1. 0/ 1,20, /42 UB NRC,66~~64,400 6,3~16,4~,84,0~61,0~0,840,3~,0~,61 2,566~5,8~6,0 2,10~6,613~, ~.3/~3 1,2~0, ~ 10~43 ~ /45/40(166/1413/) 46/44/42 4x.0x2 (x0x) (1) 5/0 UU UYB escroll 100(0.4) Top Discharge 5/56 3/8 (.52) 3/4 (1.05).**2.1 (806*1,*) 1(6) 3*5.0 4*1. 0/ 1,20, /42 Indoor Unit _ Capacity (~~) Input (~~) Running Current / A EER / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) External Static Pressure mmaq Noise Level(SoundPress,1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Stuffing Quantity ith S/Parts /40ft Outdoor Unit _ Compressor(Constant) Refrigerant Charge Charge g(oz) Fan Discharge Side/Top Noise Level Sound Press, 1m db(a)±3 Pipe Connection Liquid Dimensions xhxd Net eight Outdoor kg(lbs) Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout S/Parts /40ft UB NGC,400~34,000~3,400 5,80~,0~10,0 22,800~,000~41,800 6,680~11,140~,0 1,840~3,00~3,0 1,8~3,040~3,340 / 5 6 3,0/4, ~ 5~43 ~ 1,2~0, /2/26(11/10/) 10 42/3/ 4x11.x1.(10xx4) (84) 5/11 UU3 UEC 3,0/4, Twin 2,0(8) 51 5/8 (.88) 3x41.x.6(80x10x3) 80 5* 4*0.5 / 51/111 UB42 NGC,0~41,000~45,100,0~,0~13,2 2,400~4,000~53,00 8,6~14,~,810 2,10~3,610~3,0 2,0~3,640~4,000 / 3 3,0/4, ~ 5~43 ~ 1,2~0, //(1/11/8) 42/40/ 5.0 4x.0x2(x0x) (1) 5/0 UU43 UHC 3,0/4, Twin 4,000(141.1) 53 3/8(.52) 3/4(1.05) 3x4x14.5 (00x1165x) 5 5* 4*0.5 / 2/55 UB42 NGC,800~~52,800 8,440~14,00~,40,400~,000~,0~,8~16,410 2,8~4,0~4,8 2,8~4,0~4,.0/ ,0/4, ~ 5~43 ~ 1,2~0, 40//(1413//105) 44/42/40 4x.0x2(x0x) (1) 5/0 UU4 UHC 3,0/4, Twin 4,000(141.1) 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1,165x) 5 5* 4*1. 0/ 2/55 UB NRC,400~52,000~5,0,0~,0~16, 34,800~58,000~61,000 10,0~1,000~1,880 3,00~4,~5,0 3,100~4,00~5,0 8.0/ ,0/4, ~ 5~43 ~ 1,2~0, /45/40(166/1413/) 46/44/42 4x.0x2(x0x) (1) 5/0 UU61 UHC 3,0/4, Twin 4,000(141.1) 55 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1,165x) 5 5* 4*1. 0/ 2/55 Ceiling Concealed Duct 26 2 UU UU UU UU UU/UU UU3 UU3/UU4/UU61

15 CEILING CONCEALED DUCT TYPE SET MODEL CEILING CONCEALED DUCT TYPE BIC DUCT MODEL BAH / B42AH BAHV / BAHV / BAHV eekly Program Auto Changeover Two Thermistor Control Group Control Hour ON/OFF Child Lock Function Auto Restart Hot Start (Heat pump ) Anti Corrosion Gold Fin(Outdoor) Zone Control(Accessory) Central controller(accessory) B0AH eekly Program Auto Changeover Two Thermistor Control Group Control Hour ON/OFF Child Lock Function Auto Restart Hot Start (Heat pump ) Anti Corrosion Gold Fin(Outdoor) Zone Control(Accessory) Central controller(accessory) BAH SG0 B42AH SG0 BAHV SH0 BAHV SG0 BAHV SG0 B0AH SV0 Capacity Capacity Input Running Current A A E.E.R / C.O.P / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C I/h External Static Pressure mmaq Air Flow Rate Indoor(H/M/L) CMM(CFM) Noise Level(SoundPress,1m) Indoor(H/M/L) db(a)±3 Dimensions (*H*D) Indoor Net eight Indoor kg(lbs) Refrigerant charge g(oz), type Compressor Outdoor Fan Discharge Side/Top Noise Level(SoundPress,1m) Outdoor db(a)±3 Pipe Connection Liquid Dimensions (*H*D) Outdoor Net eight Outdoor kg(lbs) Cable No.*mm2 Connecting Cable No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout S/Parts /40ft 10,5,000 11,0,0 3,00 3, ,20, ~ 5~43 10~ 8 /2/2(11/10/) 42/40/ 46.4x11.x1.1 (10xx4) (8) 00(84.), 58 1/4(5) 5/8(.88) 3x41.x.6(80x10x3) 5(16) 3* 5*0.5 / 34/0,162 41,0,85 44,000 4,0 4, ,20, 5 ~ 5~43 10~ 8 /2/2(11/10/) 42/40/ 46.4x11. x1.1 (10xx4) (8) 30(3), 62 3/8(.52) 5/8(1.05) 3x4x14.5(00x1165x) 0(.4) 3* 5*0.5 / 2/55 6,40 23,000,61 26,000 2,0 2, ,20, ~ 5~43 10~ 4 6 /1/14(6/583/44) 3// 3x10.2x1. (880x2x4) 34(4.) 2(10), Top Discharge 1/4(5) 1/2(.).6x2.x22.(626x03x56) (1.3) 3* 5*1. / 41/86,,000 10,0 3,0 3,0 3, ,20, 4 ~ 5~43 10~ 8 /2/2(11/10/) 42/40/ 46.4x11. x1.1 (10xx4) (8) 20(1.), Top Discharge 68 1/4(5) 5/8(.88) x.6x2(x8x68) 5(16) 3* 5*1. / 2/58,64 34,000 11,4 3,000 3,4 3, ,20, 2. ~ 5~43 10~ 8 /2/2(11/10/) 42/40/ 46.4x11. x1.1 (10xx4) (8) 20(1.), Top Discharge 68 1/4(5) 5/8(.88) x.6x2(x8x68) 5(16) 3* 5*1. / 2/58 Capacity Input Running Current / A E.E.R / C.O.P / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C I/h External Static Pressure mmaq Air Flow Rate Indoor CMM(CFM) Net eight Indoor kg(lbs) Noise Level(Sound Press, 1m) Indoor db(a)±3 Dimensions (*H*D) mm Net eight kg(lbs) Refrigerant Charge g(oz),type Compressor Outdoor Fan Discharge Side/Top Noise Level (Sound Press, 1m) Outdoor db(a)±3 Pipe Connection Liquid Dimensions (*H*D) Outdoor Net eight Outdoor kg(lbs) Cable No.*mm2 Interunit Cable No.*mm2 length/elevation m Stuffing Quantity ithout S/Parts /40ft 1,000,8 1,000,100 14,0,0 / 3,04, ~ 5~43 10~ () 105(3,80) 1() 53 1,0xx800 1() 8,000(2.2), Scroll Top Discharge 65 5/8(.88) ().4xx.(1,0x1,5x) 0(661) 5* 6*1. / 6/14 Ceiling Concealed Duct 2 BAH B42AH BAHV BAHV/BAHV U0

16 LG AIR CONDITIONERS 0 CEILING & FLOOR / CEILING SUSPENDED TYPE CEILING & FLOOR / CEILING SUSPENDED TYPE Compact Size 13x6x2(K) 0x6x2(/K) eight : 65kg kg Volume : 100% 68% Gold Fin TM Anti Corrosion LG s Outdoor Heat Exchanger is coated with a golden anticorrosive epoxy treatment on the aluminum coil to minimized corrosion. This maintains heat transfer properties of the coil for an extended time where as nongold Fin coils progressively lose efficiency due to surface corrosion. Standard on every LG air conditioner, this assists in areas suffering from pollution or near the ocean where the unit may subjected to higher levels of salt. Floor / Ceiling Convertible System has the flexibility of multiple installations. The Indoor Unit can easily be mounted on the floor or suspended from the ceiling. The Convertible System features Gold Fin protection on the Outdoor Unit & Energy Saving Plasma Heat Exchanger in the Indoor Unit. Upgraded Function One Touch Filter & Filter Cleaning Alarm Function Power ind Mode ired Remote Controller (Option) eekly Program Group control. etc [Test Standard : ASTM B11, KS D2] Airflow Direction Control Horizontal Airflow Direction Control. Adjust the horizontal airflow direction by manually moving the horizontal airflow direction louver by hand. Vertical Airflow Direction Control The airflow direction can be adjusted as desired by using the remote controller. Ceiling & Floor / Suspended Horizontal Downward

17 CEILING & FLOOR TYPE SET MODEL CEILING & FLOOR TYPE COOLING ONLY V0AC / V0AH / VAC UVAC / UVAC / UVAC Anti Corrosion Gold Fin Natural ind Operation ireless Remote Controller Sleep Operation Auto Operation Soft Dry Operation OneTouch Air Filter (AntiBacteria) Hour ON/OFF Setting Timer Auto Restart Hot Start(Heat Pump Mode) Anti Corrosion Gold Fin Natural ind Operation ireless Remote Controller Sleep Operation Auto Operation Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Indoor Unit _ UVAC NBA UVAC NBA UVAC NBA Capacity Input Running Current / A E.E.R / C.O.P / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level(Sound Press, 1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Compressor Refrigerant Charge Charge g(oz) Fan Discharge Side/Top Noise Level (H/L) Sound Press, 1m db(a)±3 Pipe Connection Liquid Dimensions xhxd Net eight Outdoor kg(lbs) Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout S/Parts /40ft V0AC SEO 10,0 3,0 85 / 1,2~0, 2 ~ 5~43.5//5.0(265/2/1) // 1.0 3x1.3x.(00x40x0) (2) (2) 46 1/2 (.).x.x10.2 (5x5x2) (5) 3*1.0 3*1.0 /8 6/0 V0AH SEO,0 2,813 10,0 2, / 1,2~0, 1 5 ~ 5~43 10~.5//5.0(265/2/1) // 1.0 3x1.3x.(00x40x0) (2) (2) 4 1/2 (.).x.x10.2 (5x5x2) (5) 3*1.0 2*1.0+3*0.5 /8 6/0 VAC SEO,000 3,51 1, / 1,2~0, 3.1 ~ 5~43 10/8.0/(3/3/2) 40// 1.2 3x1.3x.(00x40x0) () 46 1/2 (.).3x.3x.6(0x0x5) 3*1.0 3*1.0 /8 82/10 Capacity Input Running Current A E.E.R / r Setting Temperature C Range(Indoor) Operational Temperature C Range(Outdoor) Air Flow Rate Indoor(H/M/L) CMM(CFM) Noise Level (SoundPress,1m) Indoor(H/M/L) db(a)±3 I/h Dimensions (xhxd) Indoor Net eight Indoor kg(lbs) Stuffing Quantity ith S/Parts /40ft Outdoor Unit _ 1,800 5,803 1, , 20, ~ 5~43 14/13/(44/45/423) 43/40/3 2.0 x.2x (1,0x6x5) 22(4) 102/ UUAC UMA Compressor Refrigerant Charge Charge g(oz) 1,000(3) Outdoor Fan Discharge Side/Top Noise Level (SoundPress,1m) Outdoor db(a)±3 Pipe Connection Liquid 1 / 4 (5) 5 / 8 (.88) Dimensions (xhxd) Outdoor.1x2x10.8(840x55x) Net eight Outdoor kg(lbs) 44() Cable(Includes earth) No.*mm2 3 * Connecting Cable(Includes earth) No.*mm2 4 * 0.5. Piping Length/Elevation m / 1,20, Stuffing Quantity ithout S/Parts /40ft 6/4,000,034 2, , 20, ~ 5~43 /14/13(5/44/45) 45/42/3 x.2x(1,0x6x5) 22(4) 102/ UUAC UEA 1,0(42.4) 55 1 / 4 (5) 5 / 8 (.88) 3x.8x.6(80x655x3) 5() 3 * 4 * 0.5 / 1,20, 81/11,0 8,2 2,. 1, 20, ~ 5~43 /16/14(6/564/44) 45/42/3 x.2x(1,0x6x5) 22(4) 102/ UUAC UEA 2,000(0.6) 1 / 4 (5) 5 / 8 (.88) 3x.5x.6(80x800x3) (1.2) 3 * 3 * 0.5 / 1,20, /114 Ceiling & Floor / Suspended UUAC UUAC UUAC

18 CEILING & FLOOR TYPE HEAT PUMP CEILING SUSPENDED TYPE HEAT PUMP UV / UV UV / UV UV / UU / UU Anti Corrosion Gold Fin Natural ind Operation ireless Remote Controller Sleep Operation Auto Changeover Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Anti Corrosion Gold Fin Natural ind Operation ireless Remote Controller Sleep Operation Auto Changeover Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Indoor Unit _ UV NEC UV NBC UV NBC UV NBC Indoor Unit _ UV NKC UU NLC UU NLC Nominal Capacity (~~) Nominal Input (~~) Running Current / A EER / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level(Sound Press, 1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Stuffing Quantity ithout/parts /40ft Outdoor Unit _ Compressor Refrigerant Charge Charge g(oz) Fan Discharge Side/Top Noise Level Sound Press, 1m db(a)±3 Pipe Connection Liquid Dimensions xhxd Net eight Outdoor kg(lbs) Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout/parts /40ft,000 3,51 13,0 3,86 1,3 1, 5/ 1,2~0, 1 2 ~ 5~43 ~ 10.0/8.3/(3/23/2) 40// 1.2 3x.x1.3 (00x0x40) (2) /3,000 5, 1,800 5,803 1,880 2,0 8.3/8. 1,2~0, 1 2 ~ 5~43 ~ 1//11(4/4/8) 43/40/3 2.3 xx.2 (00x5x6) (6) 102/,000,034 26,400,3 2,0 2, 10.8/11.2 1,2~0, 1 1 ~ 5~43 ~ /1/(5/4/4) 45/42/3 xx.2 (00x5x6) (6) 102/,000 8,6,800,02 3, 3,.8/1 1,2~0, ~ 5~43 ~ /16/14(6/564/44) 45/42/3 xx.2 (00x5x6) (6) 102/ UU ULC UU UEC UU UEC UU UEC 00(42.4) 4 3/8 (.52).3x.3x.6 (0x0x5) (68.3) 3* 4*0.5 /10 1,20, 144/3 10(45.0) 52 1/2 (.) 3x.8x.6 (80x655x3) 52(11) 3* 4*0.5 / 1,20, 81/11 0(68.) 52 1/2 (.) 3x.5x.6 (80x800x3) (1.2) 3* 4*0.5 / 1,20, /114 (81.3) 53 5/8 (.88) 3x.5x.6 (80x800x3) 64(141) 3* 4*0.5 / 1,20, /114 Nominal Capacity (~~) Nominal Input (~~) Running Current / A EER / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level(Sound Press, 1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Stuffing Quantity ithout/parts /40ft Outdoor Unit _ Compressor Refrigerant Charge Charge g(oz) Fan Discharge Side/Top Noise Level Sound Press, 1m db(a)±3 Pipe Connection Liquid Dimensions xhxd Net eight Outdoor kg(lbs) Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout/parts /40ft 34,000,65,000 10,551 4,1 4,0.8/. 1,2~0, ~ 5~43 ~ 2/2/ 44/42/ x.8x8. (1,3x6x2) 84/168 UU3 UEC 20(2.1) 52 5/8 (.88) 3x41.x.6 (80x10x3) 80(16) 3* 4*0.5 / 3,04, 51/111 46,0 13,6 52,800,45 5,6 5,0 10.0/.5 1,2~0, ~ 5~43 ~ /34/ /52/ 68.x.8x8. (1,x6x2) 45 63/1 UU UHC 40(14) for m 5 3/8 (.52) 3/4 (1.05) 3x4x14.5 (00x1165x) 105(2) 3* 4*0.5 / 3,04, 2/55,000,000,826 8,5 5,400,0 1,40,43 6,580 2,5 6,0 2,0 1/10..8/1 1,2~0, ~ 5~43 ~ /16/14(6/564/44) 40//26 56//52 45/42/3 68.x.8x8. xx.2 (1,x6x2) (00x5x6) (6) / 63/1 UU UHB SCROLL 400(1) for m 5 3/8 (.52) 3/4 (1.05) 3x4x14.5 (00x1165x) 3(5) 3* 4*0.5 / 3,04, 2/55 Ceiling & Floor / Suspended 34 UU UU UU/UU UU3 UU / UU

19 CEILING & FLOOR TYPE DC INVERTER CEILING SUSPENDED TYPE 3PHASE DC INVERTER UV / UV UV / UV UV / UV42 UV / UV Anti Corrosion Gold Fin Natural ind Operation ireless Remote Controller Sleep Operation Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Hot Start Auto Changeover Anti Corrosion Gold Fin ireless Remote Controller Sleep Operation Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Hot Start Auto Changeover OneTouch Air Filter (AntiBacteria) Indoor Unit _ Capacity (~~) Input (~~) Running Current / A E.E.R / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level (SoundPress,1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Stuffing Quantity ithout S/Parts /40ft Outdoor Unit _ UV NEC 4,0~,000~16,000 1,3~3,51~4,688 4,800~13,800~,000 1,40~4,044~5, 0~1,00~1,4 4~1,100~1,3 1.6 ~/2.0 ~ 1,2~0, 8 ~ 10~43 ~ 10.0/8.3/(3/23/2) 40// 1.2 3x.x1.3(00x0x40) (2) /3 UU UEC UV NBC 6,840~,000~,0 2,006~5,~6,,14~,0~,840 2,261~5,4~,0 623~1,640~2, 62~1,6~2, ~.5/~10.6 1,2~0, 2 1 ~ 10~43 ~ 1//11(4/4/8) 43/40/3 2.3 xx.2(00x5x6) (6) 102/ UU UEC Compressor(Inverter) escroll escroll Compressor(Constant) Refrigerant Charge Charge g(oz) 1100(40) 00(52.1) Fan Discharge Side/Top Noise Level (H/L) Sound Press, 1m db(a)±3 51/45 51/45 Pipe Connection Liquid 3/8 (.52) 1/2 (.) Dimensions (xhxd) Outdoor 3*.8*.6 (80*655*3) 3*.8*.6 (80*655*3) Net eight Outdoor kg(lbs) 46(101) 52(1) Cable(Includes Earth ) No.*mm2 3* 3* Interunit Cable(Includes Earth ) No.*mm2 4*0.5 4*0.5. Piping Length/Elevation m /10 40/ 1,20, 1,20, Stuffing Quantity ithout S/Parts /40ft 81/11 81/11 UV NBC,0~,000~,800 2,61~,034~8,440 10,8~2,0~,000 3,04~8,08~, 8~2,10~2,0 840~2,0~3,00 ~1/4.5~13. 1,2~0, 1 6 ~ 10~43 ~ /1/(5/4/4) 45/42/3 xx.2(00x5x6) (6) 102/ UU UEC escroll 0(61.2) 52/46 1/2 (.) 3*.5*.6 (80*800*3) 6(2) 3* 4*0.5 / 1,20, /114 UV NBC 10,0~26,400~,680 2,41~,3~,4 11,514~,0~,0 3,34~8,880~10,656 16~2,410~2,80 2~2,440~4,0 5.~1/~1. 1,2~0, 1 4 ~ 10~43 ~ /16/14(6/564/44) 45/42/3 xx.2(00x5x6) (6) 102/ UU UEC escroll 00() /46 5/8 (.88) 3*41.*.6 (80*10*3) 80(16) 3* 4*0.5 / 1,20, 51/111 Indoor Unit _ Capacity (~~) Input (~~) Running Current / A EER / COP / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level (SoundPress,1m) H/M/L db(a)±3 I/h Dimensions (xhxd) Net eight kg(lbs) Stuffing Quantity ith S/Parts /40ft Outdoor Unit _ UV NKC,400~34,000~3,400 5,80~,0~10,0 22,800~,000~41,800 6,680~11,140~,0 1,840~3,00~3,0 1,8~3,040~3,340 / 5 6 1,20, ~ 5~43 ~ 1,2~0, 2/2/ 44/42/ x.8x8.(1,3x6x2) (0.4) 84/168 UV42 NLC,0~42,000~46,0,~,3~13,5,0~4,000~51,00 8,~13,80~,1 2,100~3,0~3,8 2,040~3,400~3,40 / 2 5 1,20, ~ 5~43 ~ 1,2~0, ///2 /46/ x.8x8.(1,x6x2) (0.4) 63/1 UU3 UEC UU43 UHC 3,0/4, 3,0/4, Compressor(Constant) Twin Twin Refrigerant Charge Charge g(oz) 2,0(8) 4,000(141.1) Fan Discharge Side/Top Noise Level Sound Press, 1m db(a)± Pipe Connection Liquid 3/8(.52) 5/8 (.88) 3/4(1.05) Dimensions xhxd 3x41.x.6(80x10x3) 3x4x14.5 (00x1165x) Net eight Outdoor kg(lbs) 80 5 Cable(Includes earth) No.*mm2 5* 5* Interunit Cable(Includes earth) No.*mm2 4*0.5 4*0.5. Piping Length/Elevation m / / Stuffing Quantity ithout S/Parts /40ft 51/111 2/55 UV NLC,100~~52,0 8,0~14,080~,340,800~51,0~,000,340~,100~,840 2,110~4,~4,00 2,00~3,~4,0.0/ ,20, ~ 5~43 ~ 1,2~0, /34/ /52/ 68.x.8x8.(1,x6x2) (0.4) 63/1 UU4 UHC 3,0/4, Twin 4,000(141.1) 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1,165x) 5 5* 4*1. 0/ 2/55 UV NLC,000~,000~55,000 8,800~14,6~16,1,0~~61,0,8~16,4~,0 2,6~4,410~4,8 2,6~4,~4, /.1 2 1,20, ~ 5~43 ~ 1,2~0, 40//26 56//52 68.x.8x8.(1,x6x2) (0.4) 63/1 UU61 UHC 3,0/4, Twin 4,000(141.1) 55 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1,165x) 5 5* 4*1. 0/ 2/55 Ceiling & Floor / Suspended 3 UU/UU UU UU UU3 UU43/UU4/UU61

20 LG AIR CONDITIONERS 0 SYNCHRO SYNCHRO Simultaneously On/Off (1Cycle) Connectable up to 4 indoor units Only using simple branch piping MPS Inverter : /K MPS Variable : /2/100K 2 branch 2 branch 3 branch 3 branch 3 branch 4 branch Easy Installation : Chargeless m (MPS Inverter : /K) Combination Outdoor Synchro Combination(k ) Duo Trio Quartet High Efficiency & Low Noise MPS Inverter / Variable technology is applied Right for Various shape of Open Space (L,T shape) Synchro UU UHC UU UYB UU UYB UU2 UYC UU100 UC Choice of various indoor type 3 Indoor Cassette Duct Ceiling & Floor UT UT UT UT UT UT UT UB UB UB UB UB UB UV UV UV UV Long piping length and high elevation. piping length: 110m. elevation: m (*based on 100k ) m

21 SYNCHRO HEAT PUMP SYNCHRO CEILING CASSETTE TYPE UU / UU2 / UU100 UT / UT / UT / UT UT / UT / UT Plasma Air Purifying System Anti Corrosion Gold Fin eekly Program Turbo Fan High Head Drain Pump Auto Operation Low Standby Power Auto Restart Child Lock Function EasytoClean Air Filter Two Thermistor Control Optimal Air Distribution Synchro Outdoor Synchro Indoor Outdoor Units UU UHC UU2 UYC UU100 UC Running Current / A Compressor Refrigerant Charge Charge g(oz) Fan Discharge Side/Top Noise Level (H/L) Sound Press, 1m db(a)±3 Pipe Connection Liquid Dimensions *H*D Net eight Outdoor kg(lbs) Cable (Includes earth) No.*mm 2 Interunit Cable (Includes earth) No.*mm 2 Total Piping (Main+Total Branch) m. Piping Length Main Piping m Total Branch Piping m Each Branch Piping m. Installation Indoor Unit~Outdoor Unit m Height difference Indoor Unit~Outdoor Unit m Stuffing Quantity ithout S/Parts /40ft Indoor Units Nominal Capacity (~~) r Nominal Input (~~) E.E.R / C.O.P / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C 10.0 /.5 3,0~4, 40(14) for m 53(2)*2 3/8 (.52) 3/4 (1.05) 3x4x14.5(00x1165x) 105(2) 5* 4* / 55 UT/UV/UB~ N*C Synchro application (simultaneous operation). Refer to combination table ~ 5~43 ~ 14. / 1 3,0~4, 100(0.4) Top Discharge 0() 3/8 (.52) 1 (2).xx2.1 (806x0x) 0(1) 5* 4* /3 UT/UV/UB~ N*C Synchro application (simultaneous operation). Refer to combination table ~ 5~43 ~ / 1. 3,0~4, Scroll 800(2) Top Discharge 5(65) 1/2 (.) 1 (2).4x61.2x2.1 (80x55x) 2(65) 5* 4* / UT/UV/UB~ N*C Synchro application (simultaneous operation). Refer to combination table ~ 5~43 ~ F/Panel Capacity Capacity Air Flow Rate Indoor(H/M/L) CMM Noise Level(H/M/L) Sound Press,1.5m db(a)±3 l/h Dimensions Indoor Unit (xdxh) mm Decoration Panel (xdxh) mm Net eight Indoor Unit kg Decoration Panel kg Stuffing Quantity ithout S/Parts /40ft UT NEC PTHEC1 3,51,000 4,044 13,800.5/8/ // 1.2 x26x xx 1 3 / UT NEC PTHEC1 5,,000 6,065,00 13//11 41/3/3 2.4 x26x xx 1 3 / UT NFC PTHFC,0,000 8,08 2,0 /14/13 43/41/3 44x22x44 8xx8 3 84/168 UT NFC PTHFC 8,5,000,43,0 1/1/ 45/42/3 44x22x44 8xx8 3 84/168 UT NDC PTHDC1 10,,000,1 41,400 /23/ 40// 840x8x840 xx 5 2/144 UT NDC PTHDC1 14,06,44 52,800 //26 43/41/3 840x8x840 xx 5 2/144 UT NDC PTHDC1 16,4,053 61,0 34// /4/43 840x8x840 xx 5 2/144 Synchro 40 41

22 SYNCHRO CEILING CONCEALED DUCT TYPE SYNCHRO CEILING & FLOOR TYPE UB / UB / UB UB / UB / UB UV / UV / UV / UV Anti Corrosion Gold Fin ireless Remote Controller Sleep Operation Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Hot Start Auto Operation OneTouch Air Filter (AntiBacteria) Anti Corrosion Gold Fin Natural ind Operation ireless Remote Controller Sleep Operation Auto Changeover Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Synchro Indoor Synchro Indoor Synchro Indoor UB NHC UB NHC UB NGC UB NGC UB NRC UB NRC UV NEC UV NBC UV NBC UV NBC Capacity Capacity Air Flow Rate Indoor(H/M/L) CMM l/h Noise Level(H/M/L) Sound Press,1.5m db(a)±3 l/h Dimensions xdxh mm Net eight kg Stuffing Quantity ithout S/Parts /40ft 5,,000 6,065,00 1/14.5/13 4~8 /34/ x2x4 0/2,0,000 8,08 2,0 /1/14 4~8 //34 880x2x4 0/2 8,1,000 10,110 34,0 2/23/ 6~10 40// 1,0xx4 5/11 10,,000,1 41,400 /2/26 6~10 42/3/ 1,0xx4 5/11 14,06,44 52,800 40// 44/42/40 1,2x0x 5/0 16,4,053 61,0 /45/40 46/44/42 1,2x0x 5/0 Capacity 3,51,000 5,,000 Capacity 4,044 13,800 5,4 0 Air Flow Rate H/M/L CMM 10.0/8.3/ 1//11 Noise Level (H/M/L) Sound Press,1m db(a)±3 40// 43/40/3 l/h Dimensions (xhxd) mm 00x0x40 1,0x5x6 Net eight kg Stuffing Quantity ithout S/Parts /40ft /3 102/,0,000 8,08 2,0 /1/ 45/42/3 1,0x5x6 102/,3 26,400 8,880,0 /16/14 45/42/3 1,0x5x6 102/ 42 43

23 SYNCHRO DC INVERTER SYNCHRO CEILING CASSETTE TYPE UU / UU UT / UT / UT / UT UT / UT / UT Plasma Air Purifying System Anti Corrosion Gold Fin eekly Program Turbo Fan High Head Drain Pump Auto Operation Low Standby Power Auto Restart Child Lock Function EasytoClean Air Filter Two Thermistor Control Optimal Air Distribution Synchro Outdoor Synchro Indoor Outdoor Units UU UYB UU UYB Running Current / A Compressor(Inverter) Compressor(Constant) Charge g(oz) Refrigerant Charge Control Fan Discharge Side/Top Noise Level (H/L) Sound Press, 1m db(a)±3 Pipe Connection Liquid Dimensions xhxd Net eight kg(lbs) Cable (Includes earth) No.*mm 2 Interunit Cable (Includes earth) No.*mm 2 Total Piping(Main+Total Branch) m. Interunit Main Piping m Piping Length Total Branch Piping m Each Branch Piping m. Installation Indoor Unit~Outdoor Unit m Height difference Indoor Unit~Outdoor Unit m Stuffing Quantity ithout S/Parts /40ft Indoor Units Capacity (~~) l Input (~~) E.E.R / C.O.P / Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C ~26.6/8.6~2.3 1,2~0, escroll 100(0.4) L.E.V Top Discharge 5/56 3/8 (.52) 3/4 (1.05).xx2.1 (806x1,x) 142(3) 3*5.0 4* /3 UT/UV/UB~ N*B Synchro application (simultaneous operation). Refer to combination table ~ 10~43 ~.3~.3/~3 1,2~0, escroll 100(0.4) L.E.V Top Discharge 5/56 3/8 (.52) 3/4 (1.05).xx2.1 (806x1,x) 1(6) 3*5.0 4* /3 UT/UV/UB~ N*B Synchro application (simultaneous operation). Refer to combination table ~ 10~43 ~ F/Panel Capacity Capacity Air Flow Rate Indoor(H/M/L) CMM Noise Level(H/M/L) Sound Press,1.5m db(a)±3 l/h Dimensions Indoor Unit (xdxh) mm Decoration Panel (xdxh) mm Net eight Indoor Unit kg Decoration Panel kg Stuffing Quantity ithout S/Parts /40ft UT NEB PTHEC1 3,51,000 4,044 13,800.5/8/ // 1.2 x26x xx 1 3 / UT NEB PTHEC1 5,,000 6,065,00 13//11 41/3/3 2.4 x26x xx 1 3 / UT NFB PTHFC,0,000 8,08 2,0 /14/13 43/41/3 44x22x44 8xx8 3 84/168 UT NFB PTHFC 8,5,000,43,0 1/1/ 45/42/3 44x22x44 8xx8 3 84/168 UT NDB PTHDC1 10,,000,1 41,400 /23/ 40// 840x8x840 xx 5 2/144 UT NDB PTHDC1 14,06,44 52,800 //26 43/41/3 840x8x840 xx 5 2/144 UT NDB PTHDC1 16,4,053 61,0 34// /4/43 840x8x840 xx 5 2/144 Synchro 44 45

24 SYNCHRO CEILING CONCEALED DUCT TYPE SYNCHRO CEILING & FLOOR TYPE UB / UB / UB UB / UB / UB UV / UV / UV / UV Anti Corrosion Gold Fin ireless Remote Controller Sleep Operation Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Hot Start Auto Operation OneTouch Air Filter (AntiBacteria) Anti Corrosion Gold Fin Natural ind Operation ireless Remote Controller Sleep Operation Auto Changeover Soft Dry Operation Hour ON/OFF Setting Timer Auto Restart Synchro Indoor Synchro Indoor Synchro Indoor UB NHB UB NHB UB NGB UB NGB UB NRB UB NRB UV NEB UV NBB UV NBB UV NBB Capacity Capacity Air Flow Rate Indoor(H/M/L) CMM l/h Noise Level(H/M/L) Sound Press,1.5m db(a)±3 l/h Dimensions xdxh mm Net eight kg Stuffing Quantity ithout S/Parts /40ft 5,,000 6,065,00 1/14.5/13 4~8 /34/ x2x4 0/2,0,000 8,08 2,0 /1/14 4~8 //34 880x2x4 0/2 8,1,000 10,110 34,0 2/23/ 6~10 40// 1,0xx4 5/11 10,,000,1 41,400 /2/26 6~10 42/3/ 1,0xx4 5/11 14,06,44 52,800 40// 44/42/40 1,2x0x 5/0 16,4,053 61,0 /45/40 46/44/42 1,2x0x 5/0 Capacity 3,51,000 5,,000 Capacity 4,044 13,800 5,4 0 Air Flow Rate H/M/L CMM 10.0/8.3/ 1//11 Noise Level (H/M/L) Sound Press,1m db(a)±3 40// 43/40/3 l/h Dimensions (xhxd) mm 00x0x40 1,0x5x6 Net eight kg Stuffing Quantity ithout S/Parts /40ft /3 102/,0,000 8,08 2,0 /1/ 45/42/3 1,0x5x6 102/,3 26,400 8,880,0 /16/14 45/42/3 1,0x5x6 102/

25 Combination Table UU UHC DUO TRIO QUARTET , Capacity Combination of Indoor Units (k ) Input () Current (A) Total Possibility DUO TRIO QUARTET ,000 52,800 52,800 52,800 52, Capacity Combination of Indoor Units (k ) Current (A) Input () Total Possibility UU UYB DUO TRIO QUARTET 16,3,65,65,65,65 Capacity Combination of Indoor Units (k ) Current (A) Input () 42, ,0 55,0 55,0 55,0 55, ,8 2,5 2,1 2,1 2,5 4,3 4,51 4,51 4,51 4,51 4,5 5,0 5, 5, 5,0 Total Possibility DUO TRIO QUARTET,3,455,455,455,455 Capacity Combination of Indoor Units (k ) Current (A) Input () kw,0 55,0 55,0 55,0 55, ,5 63,0 63,0 63,0 63, ,1 2, 2,2 2,2 2, 4,1 5,044 5,081 5,081 5,044 5,0 5,00 5,8 5,8 5,00 Total Possibility kw UU2 UYC DUO TRIO QUARTET 66,000 2,000 2,000 2,000 2,000 2,000 2, Current (A) Current (A) Capacity 2,0,0,0,0,0,0, Current (A) Input () Capacity Combination of Indoor Units (1K ) Total Possibility UU100 UC DUO TRIO QUARTET 84,000 6,000 6,000 84,000 84,000 0,000 6, ,000 6, Capacity Combination of Indoor Units (1K ) Total Possibility SYNCHRO SYNCHRO Combination Table DUO TRIO QUARTET,8,66,66,8,66,65 Capacity Combination of Indoor Units (k ) Current (A) Input () kw ,000, ,100 64,400 64,400 62,100 64,400 55, ,4 2,566 2,566 2,4 2,566 2,086 5,58 5,8 5,8 5,58 5,8 4,40 6,4 6,6 6,6 6,4 6,6 5,451 Total Possibility DUO TRIO QUARTET,140,0,0,140,0,4 Capacity Combination of Indoor Units (k ) Current (A) Input () kw ,100 64,400 64,400 62,100 64,400 55, ,0 0,840 0,840 68,0 0,840 63, Total Possibility UU UYB Current (A) Input () 6,0 110, ,400 6,0 6,0 103,0 110,400 11,0 110, Capacity Current (A) Input () Synchro 4

26 SYNCHRO Installation Information 1. Piping Connections Indoor Cassette UT UT UT UT UT UT UT Duct UB UB UB UB UB UB UB Ceiling & Floor UV UV UV UV Outdoor MPS Variable UU UU UU UU UU3 UU UU MPS Inverter UU UU UU UU UU UU UU Liquid øinch [mm] 3/8 (.52) 3/8 (.52) øinch [mm] 3/8 (.52) 1/2 (.) 1/2 (.) 5/8 (.88) 5/8 (.88) 3/4 (1.05) 3/4 (1.05) 2. Outdoor MPS Variable UU UU UU UU UU3 UU UU ø, Voltage 1,2~0 1,2~0 1,2~0 1,2~0 3,0~4 3,0~4 3,0~4 Outdoor MPS Inverter UU UU UU UU UU UU UU ø, Voltage 1,2~0 1,2~0 1,2~0 1,2~0 1,2~0 1,2~0 1,2~0 3. Additional Refrigerant Charge Outdoor MPS Variable UU UU UU UU UU3 UU UU Refrigerant Charge (g/m) Outdoor MPS Inverter UU UU UU UU UU UU UU Refrigerant Charge (g/m) UU, UU, UU, UU, UU3, UU, UU, UU, UU, UU, UU, UU : Over.5m UU, UU : Over m 4. Drain Pipe Indoor Cassette UT UT UT UT UT UT UT Drain Pipe (*OD/ID) / / / / / / / Indoor Duct UB UB UB UB UB UB UB Drain Pipe (OD/ID) / / / / / / / Indoor Ceiling & Floor UV UV UV UV Drain Pipe (OD/ID) 26/ 26/ 26/ 26/ *OD: Out Diameter / ID: In Diameter Measurement Conditions 1. Capacities are based on the following conditions: : Indoor Temperature 2 o C DB /1 o C B Outdoor Temperature o C DB / o C B : Indoor Temperature o C DB / o C B Outdoor Temperature o C DB / 6 o C B Piping Length.5 m Level Difference Zero. Synchro Branch Pipe Indoor Indoor Capacity Ratio(%) PMUB11A PMUB23A PMUB2A PMUB1A PMUB111A PMUB1111A 2 units 3 units 4 units : (1:1) 40: (2:3) :40:40 (1:2:2) :: (1:1:2) :: (1:1:1) ::: (1:1:1:1) 51

27 LG AIR CONDITIONERS 0 FLOOR STANDING TYPE FLOOR STANDING TYPE PLASMA Air Purifying System The PLASMA Air Purifying System within the air conditioner removes microscopic contaminants and dust to eliminate offensive odors and prevent allergic reactions. It can also be used as an airpurifying unit even though the aircooling function is off. Dust particles Ionizer Dust electrode discharge PhotoCatalyst Coated Mesh 4ay Auto Swing (P03AH) Hot or cold air can be evenly distributed throughout the room as the auto swing function blows air in 4 directions. Touch Screen Panel +KV discharge + Polluted Air Purified fresh Air LED MODULE This is a floor standing type that blends in perfectly with the surrounding decoration. Clean and fresh air conditioning is ensured with a high level of cooling or heating performance and air purifying operation. (%) (%) 100 Odour Natural Plasma 45 Plasma Natural () () Air Purifying Filter captures particles as small as 0.1 micron (micron) Visible with an Visible with an optical Visible with the electron microscope microscope naked eye Soot Cigarette smoke particles Insecticide particles Viruses Mould spores Bacteria Pollen Dust harmful to lungs Dust particles in the air Odour molecule Generating plasma Dust Reduction Respirable particles from 5 cigarettes in a sealed room removed by LG Plasma Air Purifying System Deodorization LG's Plasma unit effectively removes high concentration tobacco odors confirmed in Sensory tests of odor index carried out in Korea and Japan. AntiAllergy In clinical tests, the plasma unit has earned a satisfaction ratio of 82%. Evaluated by CSIRO Australia (DBCE Doc 8/4) Tested by Korean Food Research Institute and Japanese Environmental Centre and Yonsei Univ. College of Medicine. (Allergy Research Lab.) AntiBacteria Filter It removes dust in the air as well as bacteria proliferation, making the indoor atmosphere healthy. Child Lock Function This function prevents children or others from tampering with the control buttons on the unit. It is then controlled by the remote controller. All the buttons on indoor display panel will blocked. The unit will be controlled only by remote controller. Duct Operation (P08AH only) Depending on the room size and shape, if the unit is installed in a Ducttype manner you are able to cool more air at the same time to save energy. Floor standing type 52 53

28 FLOOR STANDING TYPE HEAT PUMP FLOOR STANDING TYPE HEAT PUMP P03AH / P05AH P08AH PLASMA Air Purifying System Jet Cool Operation ireless Remote Controller Auto Swing Soft Dry Operation Mode Hour OFF Setting Timer OneTouch Air Filter (AntiBacteria) Auto Restart Child Lock Function Anti Corrosion Gold Fin(Outdoor) Electric Heater Touch Pad(P03AH Only) Soft Dry Operation Mode Hour OFF Setting Timer ireless Remote Controller OneTouch Air Filter (AntiBacteria) Auto Restart Child Lock Function Duct Operation Electric Heater PLASMA Hour OFF Setting Timer Child Lock ireless ess Remote Controller PLASMA Hour OFF Setting Timer Child Lock ireless ess Remote Controller P03AH SR1 P05AH ST0 P08AH SF0 Capacity Input E.E.R / C.O.P / Running Current A A Electric Heater Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level(Sound Press, 1m) H/M/L db(a)±3 I/h Dimensions (*H*D) Indoor Net eight Indoor kg(lbs) Compressor Refrigerant Charge Charge g(oz) Fan(Outdoor) Discharge Side/Top Noise Level(Sound Press, 1m) Outdoor db(a)±3 Dimensions (Outdoor) *H*D Net eight Outdoor kg(lbs) Pipe Connection Liquid Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout S/Parts /40ft 2,800 8,140 2,800 8, ,2~0, 2,000 5 ~ ~ + /16/13(6/565/45) /46/ *1.*.5(**) (3) 20(.6) "at.5m" Side discharge 58 *.*.6 (80*655*) 63(13) 3/8 (.52) 5/8 (.88) 3* 4*0.5 / /65 46,000 13,0 14, ,0~4, 4,000 5 ~ +46 ~ + /26/23(1,0//8) 53/51/ 2**1.3(**440) (1) Scroll 0(102.3) "at.5m" Side discharge 58.3*.3*10 (0*0*5) 0() 3/8 (.52) 3/4 (1.05) 3* 4*1. 40/ / Capacity Input E.E.R / C.O.P / Running Current / A A Electric Heater Setting Temperature C Range(Indoor) C Operational Temperature C Range(Outdoor) C Air Flow Rate H/M/L CMM(CFM) Noise Level(Sound Press, 1m) H/M/L db(a)±3 I/h Dimensions (*H*D) Indoor Net eight Indoor kg(lbs) Compressor Refrigerant Charge Charge g(oz) Fan(Outdoor) Discharge Side/Top Noise Level(Sound Press, 1m) Outdoor db(a)±3 Dimensions (Outdoor) *H*D Net eight Outdoor kg(lbs) Pipe Connection Liquid Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2. Piping Length/Elevation m Stuffing Quantity ithout S/Parts /40ft 2,000,100 88,000, ,0~4, 5,000 5 ~ +46 ~ + 5//(13//165) / / **1.5(10*80*45) 1() Scroll 5(26) "at.5m" Top discharge 65 3*.8*.6 (80*655*3) 0(1) 5/8 (.88) 1 (2) 3* 4*1. / 10/22 Floor standing type 55 P03AH P05AH P08AH

29 LG AIR CONDITIONERS 0 ROOFTOP TYPE ROOFTOP TYPE Typical Installation 1.Roof Jack Installation 2.Roof Curb Installation 3.Slab on Ground Installation 1 2 Easy Installation The unit can be installed to save valuable indoor space or where no ceiling space is available. Install the unit on the ground or on the roof.this means that the installation is totally flexible depending on your requirements. 3 This is an economical and userfriendly product suitable for premium sized houses and shops. It features various functions including Auto Restart, ashable Antibacteria Filter, etc. Free Easy Air Circulation You can freely control aircirculation with the duct system. Low Noise Operation As the unit is located outdoors, the noise is not transmitted to the conditioned area.. Easy Maintenance & Service Since the unit has not been split into two, maintenance is easy, especially because all access panels are on the same side of the same side of the unit and all wiring inside has been colour coded. Additional functions available with duct system All units comes standard in Reverse Cycle, however electric heating can be added(electric provided by Specialist Dealers). You have complete control over the fresh air input, amount of air purification and zone controls(extras provided by Specialist Dealers), all using the powerful LG control system. Rooftop type 56 5

30 ROOFTOP TYPE HEAT PUMP ROOFTOP TYPE HEAT PUMP R0AH R0AH / R0AH eekly Program Low Standby Power Auto Operation Group Control Hour ON/OFF Child Lock Function Auto Restart Anti Corrosion Gold Fin(Outdoor) Phase Failure Protector Phase Reverse Protector Free (Option) eekly Program Low Standby Power Auto Operation Group Control Hour ON/OFF Child Lock Function Auto Restart Anti Corrosion Gold Fin(Outdoor) Phase Failure Protector Phase Reverse Protector Free (Option) R0AH Capacity Electrical Data V, ø, Hz M.C.A Amps (with standard motor) Amps Power Input Performance Air Circulation Nominal CFM CFM EER COP Sound bell Indoor Fan Diameter(idth) inch Drive / Motor Step Motor rpm(standard / oversized) Outdoor Fan No. Used / Diameter(inch) Drive CFM Motor RPM l/h Refrigerant Refrigerant Charge kg lbs Dimensions xhxd inch mm Net eight kg lbs Stuffing Quantity ithout S / Parts /40/40t HI R0AH AKH08C00 1,000,8 1,000 26,62 0~4, 3, ,400 11,0 3, Centrifugal Blower (11) Belt / 1 1,400 / 1,4 Propeller 2EA / 2 Direct 6,0 10 / Circuit. / Circuit 85 /16 x 4 x 5 8/16 2,10 x 1,4 x 1, /8/16 Capacity Electrical Data V, ø, Hz M.C.A Amps (with standard motor) Amps Power Input Performance Air Circulation Nominal CFM CFM EER COP Sound bell Indoor Fan Diameter(idth) inch Drive / Motor Step Motor rpm (Standard / oversized) Outdoor Fan No. Used / Diameter(inch) Drive CFM Motor RPM l/h Refrigerant Refrigerant Charge kg lbs Dimensions xhxd inch mm Net eight kg lbs Stuffing Quantity ithout S / Parts /40/40t HI R0AH EKH08C00, AKH08C00 166,000,6 0,000 45, 0~4, 3, ,000 1,000 5, Centrifugal Blower () Belt/1 1,0 ~1,400 / 1,400 ~1,4 Propeller 2EA / 2 Direct 6, (A)+2.(B) 10.(A)+(B) 8 13/16 x 4 x 10/16 2,2x1,4x1,0 5 1,2 3//14 R0AH EKH08C00, AKH08C00 2,000 65,41 0,000 3,268 0~4, 3, 26,40 2, 8, Centrifugal Blower () Belt/1 3,80~2,00/2,80~2,00 Propeller 4EA/22 Direct,0 /Circuit./Circuit 114 2/16 x 4 3/16 x 86 10/16 2,88x1,0x2,0 00 1,84 2/4/8 R0AH Rooftop type 58 5

31 LG AIR CONDITIONERS 0 MULTI SPLIT AIR CONDITIONERS MPS(MULTI POER SYSTEM) MPS is a stateoftheart technology which uses 2 or more compressors which consists of 1 main compressor & 1 or more extra compressor(s). hile the main compressor continues to run throughout the whole operation the extra compressor(s) turn on or off according to the load conditions. Thus saving inappropriate use of energy during low load operations. MPS Variable: A Multi Power System which uses constant compressors for main & extra compressor(s). MPS Inverter : A Multi Power System which uses an inverter compressor for the main compressor and constant compressors for the extra compressors. Inverter : A power system which uses one powerful inverter compressor. For Commercial Sites 1way Ceiling Cassette 4way Ceiling Cassette Ceiling Concealed Duct (High) hy? LG orld s Best seller for 6 years Ceiling Concealed Duct (Low) For Residential Sites Ceiling Concealed Duct (Builtin) Ceiling & Floor 61 ide Range Various s Free Combination. 0% Energy Saving Convenient Central Controller Long Piping Mirror all Mounted

32 LG AIR CONDITIONERS 0 MULTI SPLIT AIR CONDITIONERS ide Range LG Multi systems provide various indoor units and outdoor units up to 3. More than 2,000 types of combinations are available using 1 outdoor units and 4 indoor units Free Combination with Various Indoor s MULTI SPLIT AIR CONDITIONERS CEILING CASSETTE TYPE (Inverter) (Based on Heat Pump) Phase Indoor Units Feature Capacity Range (kbtu/) 14/ 16/4. / /.0 / Product Feature /2.1 Capacity Range (kbtu/) / / / /.0 / / 2 all Monted 1ø, 2V 3 4 Deluxe (Inverter+DB*) Phase Indoor Units Feature Capacity Range (kbtu/) / 40/11. /1 56/16.4 Panel 1ø, 2V Phase 3ø, 0~ 4V 6 8 Indoor Units 6 8 Capacity Range (kbtu/) / 42/.8 /1 /.8 Ceiling Concealde Duct Ceiling & Floor Gallery Builtin Low Static Slim Duct Phase Indoor Units Feature Capacity Range (kbtu/) 14/ / / / High Static ay 1ø, 2V 3 Cassette 4ay 4 * Distributor Box

33 LG AIR CONDITIONERS 0 MPS INVERTER TECHNOLOGY which is using DC Inverter compressor and MPS control. 0% Energy Saving with MPS Inverter Control The MPS Inverter Multi is an energy saving airconditioning system which uses one high efficiency constant speed compressor and a DC inverter compressor. MPS Inverter System Quick & Inverter units operate at high power until the room reaches the preset temperature, this will Cool / Heat % faster than conventional air conditioning units. Temp Top Class Energy Level You can adjust the air flow either vertically or horizontally depending on the characteristics of the space where it's installed. COP Conventional Setting Temp.. 0% Energy Saving with MPS Inverter Control Top Class Energy Lebel Quick & Comfortable Long & High Elevation Piping 3 Phase Multi FDx Compact Size, ez Installation Multi FDX System Compact size of distributor Branch and Liquid branch pipes with flare type ø.52 ø 1.05 DC Inverter Comp. 100% Capacity 100% Capacity Energy Saving Power Loss Zone Constant Speed Comp. Load Operating Ratio Conventional(On/Off Operation) Saving Zone 40% % MPS Control 100% Load Operating Ratio Indoor Temp INVERTER Conventional INVERTER on Time Comfortable LG Inverter units operate at HIGH POER until the room reaches the preset temperature, then at low power, to maintain the temperature in the room. Setting Temp. off Time K 42K K K m 10m L2 L1 Long & High Elevation Piping The FM56AH supports a piping length of up to 0m and high elevation of up to m for more flexibility in installation Outdoor unit A Indoor unit L3 Distributor Annual Power Consumption 100%. 0% Energy Saving *Distributor Piping Length(m) Total Pipe (A+L1+L2+L3) FM40AH FMAH FM56AH Main Pipe (A) 55% 0% Total Branch Pipe (L1+L2+L3) Each Branch Pipe 0 % Indoor~Outdoor Indoor~Indoor Constant Speed AC Inverter MPS Inverter(DC) *Condition of trial : ISO51

34 Indoor Units Outdoor Units Various Indoor Units Specifications_Outdoor Units all Mounted all Mounted Mirror Gallery Ceiling Cassette 1way 4way Ceiling Concealed Duct Builtin Low Slim Duct High Ceiling & Floor 2.1 MS0AH N40 MC0AH* NZ1 MC0AH* NE0 MS0AH N40 MSAH N40 MC0AH* NU1 MC0AH* NE0 MA0AH* NP1 MA0AH* NF0 MT0AH NC1 MT10AH NE1 MB0AHB NP0 MB0AHL NT0 MB0AHL N10 MV0AH NE0 MCAH* NU1 MCAH* NE0 MAAH* NP1 MAAH* NF0 MT11AH NC1 MTAH NE1 MBAHB NP0 MBAHL NT0 MBAHL N10 MVAH NE0 FMAH UL2 FM1AH UL0 FMAH UE0 FM1AH UE0 FMAH UE0 FMAH UE0 FMAH UE0. MSAH N MSAH N MCAH* N MTAH NE1 MBAHL NT0 MBAHL N MBAH NH0 MVAH NB0 MCAH* N MTAH NH0 MBAHL N MBAH NH0 MVAH NB0 Note : * indicates color of panel *Metal(M) *Mirror(R) *Silver(V) *Red(E) *Gold(G) *hite Silver(H) *ood(d) *Blue(B) *Mirror(R) *Cherry(C) *hite ood() *Blue(B) *ood(d) *Metal(M) *Blue(B) *hite ood() *Gallery(1) *hite Silver *Metal(M) *Blue(B) *Cherry(C) *Mirror(R) *Silver(V) *hite ood() *Red *Gold *Silver *ood(d) *Mirror(R) *Blue(B) *ood(d) *Blue(B) *Metal(M) *hite ood() Capacity* Capacity* r Input * Running Current* A A COP* / EER* /. Number of Connectable Indoor Units Refrigerant charge Charge g(oz) Air Circulation Outdoor CMM(CFM) Noise Level (H/L) SoundPress,1m db(a)±1 Operational Temperature C (Outdoor Unit) C Defrosting SVC Valve Liquid Dimensions *H*D Net eight Outdoor kg(lbs) Cable No.*mm2 Interunit Cable No.*mm2. Interunit Piping Total of Each Room m Length For One Room m. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Testing Combinations Stuffing Quantity /40ft FMAH UL ,2~0, 2 (3) "at.5m" () 51 5 ~ +46 ~ + Invertion cycle *2EA 3/8 (.52)*2EA.3x.3x10 (0x0x5) 3(81.6) 3*(Includes earth) 4*0.5 (Includes earth).5 MS10AH+MSAH 144/3 FM1AH UL ,2~0, 2 (3) "at.5m" () 51 5 ~ +46 ~ + Invertion cycle *2EA 3/8 (.52)*2EA.3x.3x10 (0x0x5) 3(81.6) 3*(Includes earth) 4*0.5 (Includes earth).5 MSAH+MSAH 144/3 FMAH UE ,2~0, 2 16(5.) "at.5m" 53(166) 51/45 5 ~ +46 ~ + Invertion cycle *3EA 3/8 (.52)*3EA 3x.8x.6 (80x655x3) 52(1) 3*(Includes earth) 4*0.5 (Includes earth) 40.5 MSAH+MSAH 80(81)/10(11) FM1AH UE ,2~0, 3 16(5.) "at.5m" 53(166) 51/45 5 ~ +46 ~ + Invertion cycle *3EA 3/8 (.52)*3EA 3x.8x.6 (80x655x3) 52(1) 3*(Includes earth) 4*0.5 (Includes earth) 40.5 MS10AH*2+MSAH 80(81)/10(11) FMAH UE ~ ,2~0, 3 0(4) "at.5m" 51(01) 52/46 5 ~ +46 ~ + Invertion cycle *4EA 3/8 (.52)4EA 3x.8x.6 (80x808x3) 6(2) 3*(Includes earth) 4*0.5 (Includes earth) 45.5 MS10AH*2+MSAH /114 FMAH UE ~ ,2~0, 4 20(4) "at.5m" 51(01) 52/46 5 ~ +46 ~ + Invertion cycle *4EA 3/8 (.52)4EA 3x.8x.6 (80x808x3) 6(2) 3*(Includes earth) 4*0.5 (Includes earth).5 MS10AH*3+MSAH /114 FMAH UE , , ,2~0, 4 00(88.) "at.5m" (11)*2 /46 5 ~ +46 ~ + Invertion cycle *4EA 3/8 (.52)*4EA 3x40.x.6 (80x10x3) 80(16) 3*(Includes earth) 4*0.5 (Includes earth) 0.5 MS10AH*3+MSAH 51/111 Notes: 1. Capacities are based on the following conditions: : Indoor Temperature 2 (80.6 F) DB /1 (6 F) B Outdoor Temperature (5 F) DB / (5.2 F) B : Indoor Temperature (68 F) DB / (5 F) B Outdoor Temperature (4 F) DB / 6 (4 F) B Piping Length Interconnecting Piping Length.5m Level Difference of Zero. 2. * : See page "Combination Table"2 Page. 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected. 66 6

35 Indoor Units Outdoor Units Various Indoor Units Specifications_Outdoor Units all Mounted all Mounted Mirror Gallery Ceiling Cassette 1way 4way Ceiling Concealed Duct Builtin Low Slim Duct High Ceiling & Floor Ceiling Suspended 2.1 MS0AH N40 MC0AH* NZ1 MC0AH* NE0 MS0AH N40 MC0AH* NU1 MC0AH* NE0 MA0AH* NP1 MA0AH* NF0 MT0AH NC1 MT10AH NE1 MB0AHB NP0 MB0AHL NT0 MB0AHL N10 MV0AH NE0 MSAH N40 MCAH* NU1 MCAH* NE0 MAAH* NP1 MAAH* NF0 MT11AH NC1 MTAH NE1 MBAHB NP0 MBAHL NT0 MBAHL N10 MVAH NE0 FM40AH UH0 FMAH UY0 FM56AH UY0.0 MSAH N MSAH N MCAH* N MTAH NE1 MBAHL NT0 MBAHL N MBAH NH0 MVAH NB0 MCAH* N MTAH NH0 MBAHL N MBAH NH0 MVAH NB0 Note : * indicates color of panel *Metal(M) *Mirror(R) *Silver(V) *Red(E) *Gold(G) *hite Silver(H) *ood(d) *Blue(B) *Mirror(R) *Cherry(C) *hite ood() *Blue(B) *ood(d) *Metal(M) *Blue(B) *hite ood() *Gallery(1) *Metal(M) *Blue(B) *Cherry(C) *Mirror(R) *Silver(V) *hite ood() *ood(d) *Mirror(R) *Blue(B) MBAH NG0 MBAH NG0 *ood(d) *Metal(M) MV NK0 Capacity* Capacity* r Input * Running Current* A A COP* / EER* /. Number of Connectable Indoor Units Refrigerant charge Charge g(oz) Air Circulation Outdoor CMM(CFM) Noise Level (H/L) SoundPress,1m db(a)±1 Operational Temperature C (Outdoor Unit) C Defrosting SVC Valve Liquid Dimensions *H*D Net eight Outdoor kg(lbs) Cable No.*mm2 Interunit Cable No.*mm2 Total Piping m. Interunit Piping Total Main Piping m Length Total Branch Piping m For One Room m. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Testing Combinations Stuffing Quantity /40ft FM40AH UH ~ ,2~0, (14) "at 5m" 53(2) *2 58/ 5 ~ +46 ~ + Reversing cycle 3/8 (.52) 3/4 (1.05) 3x4x14.5 (00x1,165x) 105(2) 3*5.0(Includes earth) 4*0.5 (Includes earth) MS10AH*5+MS0AH 2/55 FMAH UY ,2~0, 100(0.4) "at 5m" 0() 5/56 5 ~ +46 ~ + Invertion cycle 3/8 (.52) 3/4 (1.05).xx. (806x1,5x) 142(3) 3*5.0(Includes earth) 4*0.5 (Includes earth) MS10AH* /42 FM56AH UY ,2~0, 8 100(0.4) "at 5m" 0() 5/56 5 ~ +46 ~ + Invertion cycle 3/8 (.52) 3/4 (1.05).xx. (806x1,5x) 1(6) 3*5.0(Includes earth) 4*0.5 (Includes earth) MS10AH*8 /42 *hite Silver *Red *Gold *Silver *Blue(B) *hite ood() Notes: 1. Capacities are based on the following conditions: : Indoor Temperature 2 (80.6 F) DB /1 (6 F) B Outdoor Temperature (5 F) DB / (5.2 F) B : Indoor Temperature (68 F) DB / (5 F) B Outdoor Temperature (4 F) DB / 6 (4 F) B Piping Length Interconnecting Piping Length.5m Level Difference of Zero. 2. * : See page "Combination Table" 8 Page 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected. 5. imum combination capacity rate should be more than 40%. 68 6

36 Indoor Units Outdoor Units 3 Phase Multi FDx High efficiency and less noise have been realized by applying the latest inverter technology. Compact Size, Easy Installation Conventional NE Specifications_Outdoor Units Effciency COP kBtu kbtu kbtu New Conventional Capacity 806x55x Volume Ratio 00x1165x 806 Installation Area Ratio 00 "D"Company k / k / k Noise Level COP New Conventional FM3AH UE0 FM41AH UH0 FM4AH UH0 FM5AH UH0 A m L1 10m L2 L3 Indoor unit Outdoor unit Various Indoor Units Distributor all Mounted all Mounted Mirror kBtu kbtu kbtu *Based on the testing conducted by the producer of the device. 145m Total System Long Piping Gallery Ceiling Cassette 1way Capacity Piping Length(m) Total Pipe (Main + Branch) Indoor Unit~Outdoor Unit Total Branch Piping Total Branch Piping For One Room Total system piping length of up to 145m and high elevation of up to m for more flexibility in installation k 4way 100m m 40m m m 42 5m m 55m m m Ceiling Concealed Duct 1m m 55m 80m m Low Slim Duct High 5 145m m 55m 80m m Ceiling & Floor Capacity (~~) Input (~~MAX) EER / COP / Running Current A A. Number of Connectable Indoor Units Refrigerant charge Charge g(oz) Noise Level (H/L) SoundPress,1m db(a)±3 Operational Temperature C (Outdoor Unit) C Dimensions (xhxd) Net eight Outdoor kg(lbs) SVC Valve Liquid Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2 Total Piping m. Interunit Total Main Piping m Piping Length Total Branch Piping m For One Room m. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Testing Combinations Stuffing Quantity ith(ithout) S/Parts/40ft FM3AH UEO ,0~4, 6 00() 51/4 5 ~ +43 ~ + 3*41.*.6 (80*1,0*3) 80(16) 5/8 (.88) 5* 4* MSAH*2 51/111 FM41AH UHO ~ ,0~4, 40(162.3) 53/ 5 ~ +43 ~ + 3*4*14.5 (00*1,165*) 5 () 3/8 (.52) 3/4 (1.05) 5* 4* MSAH+MSAH*2 2/55 FM4AH UHO ~1400~ ,0~4, 8 40(162.3) /51 5 ~ +43 ~ + 3*4*14.5 (00*1,165*) 5 () 3/8 (.52) 3/4 (1.05) 5* 4* MSAH*2+MSAH 2/55 FM5AH UHO ~ ,0~4, 40(162.3) 55/52 5 ~ +43 ~ + 3*4*14.5 (00*1,165*) 5 () 3/8 (.52) 3/4 (1.05) 5* 4* MSAH*3 2/ MS0AH N40 MS0AH N40 MSAH N40 MC0AH* NZ1 MC0AH* NE0 MC0AH* NU1 MC0AH* NE0 MA0AH* NP1 MA0AH* NF0 MT0AH NC1 MT10AH NE1 MB0AHL NT0 MB0AHL N10 MV0AH NE0 MCAH* NU1 MCAH* NE0 MAAH* NP1 MAAH* NF0 MT11AH NC1 MTAH NE1 MBAHL NT0 MBAHL N10 MVAH NE0 Notes: 1. Capacities are based on the following conditions: : Indoor Temperature 2 (80.6 F) DB /1 (6 F) B Outdoor Temperature (5 F) DB / (5.2 F) B : Indoor Temperature (68 F) DB / (5 F) B Outdoor Temperature (4 F) DB / 6 (4 F) B Piping Length Interconnecting Piping Length.5m Level Difference of Zero. 2.*See page "Combination Table" 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected. 5. imum combination capacity rate should be more than 40%. 0 1 MSAH N MCAH* N MTAH NE1 MBAHL NT0 MBAHL N MBAH NH0 MVAH NB0.0 MSAH N MCAH* N MTAH NH0 MBAHL N MBAH NH0 MVAH NB0 Note : * indicates color of panel *Metal(M) *Mirror(R) *Silver(V) *Red(E) *Gold(G) *hite Silver(H) *ood(d) *Blue(B) *Mirror(R) *Cherry(C) *hite ood() *Blue(B) *ood(d) *Metal(M) *Blue(B) *hite ood() *Gallery(1)

37 Accessory Accessory Distributor Box Convenient Central Controller Distributor Box Convenient Central Controller Large Capacity Multi Systems with Distributor Box Capacity (k) Simple Central Controller The simple central controller that can operate up to 16 units simultaneously. PI5 1 Phase 3Phase PQCSA101S0 PMNFP14A0 Connecting with Flare and Nuts Installers can connect pipes to outdoor units, indoor units, branches and distributors without brazing. Easy Installation with Various Distributor Box For 2 Indoors Flare 3 Indoors 4 Indoors Deluxe Central Controller ith an intuitively designed GUI and a userfriendly touch panel, you can simultaneously control up to 6 indoor units, and the system can be linked to the building management system. Deluxe Central Controller CNU PQNFG00AO PQCS2A0 PI5 PMNFP14A0 Distributor PMBD PMBD2 Specifications_Distributors Connectable Number of Indoor Units Indoor Units Capacity Casing color ø,v,hz Power Consumption Runing Current A Dimensions xhxd Packing Dimension xhxd Net eight kg Connecting Cable Direction Indoor Unit No.* mm2 Direction Outdoor Unit No.* mm2 Piping Connection Liquid (To Outdoor Unit) Piping Connection Liquid (To Indoor Unit) Piping Length m Piping Elevation m Drain hose Heat Insulation Hanger EA Screw EA Accessories Connector EA Manual EA PMBD 1~2 k/k/k/k/k Paintingless 1, 2~0/2V, / **10. (342*165*22).6*8.0*11.8 (8*2*0) 4*0.5 (Includes earth) 4*0.5 (Includes earth) 3/8 (.52) 3/4(1.05) *2 3/8 (.52)* PMBD PMBD2 Various distributors can make much easier installation for any sites PMBD2 1~3 k/k/k/k Paintingless 1, 2~0/2V, / **10. (342*165*22).6*8.0*11.8 (8*2*0) 5.0 4*0.5 (Includes earth) 4*0.5 (Includes earth) 3/8 (.52) 3/4(1.05) *2 1/2(.)*2 Note : 1. BD unit or Indoor Unit. Height <> BD unit or Indoor Unit. Height :.10m Set up the BD unit and Indoor Unit in m. 2. The piping connection must be suit the piping sizes of the indoor unit which will be connected. (If need, use the connector which is included in the indoor unit) 3. The BD should be installed inside the building PMBD 1~3 k/k/k/k/k Paintingless 1, 2~0/2V, / **10. (342*165*22).6*8.0*11.8 (8*2*0) 4. 4*0.5 (Includes earth) 4*0.5 (Includes earth) 3/8 (.52) 3/4(1.05) *3 3/8 (.52)*3 Unusable Both Liquid and pipes PMBD40 PMBD40 1~4 k/k/k/k/k Paintingless 1, 2~0/2V, / **10. (342*165*22).6*8.0*11.8 (8*2*0) 5.0 4*0.5 (Includes earth) 4*0.5 (Includes earth) 3/8 (.52) 3/4(1.05) *4 3/8 (.52)* PMBD2 1~3 k/k/k/k Paintingless 1, 2~0/2V, / **10. (342*165*22).6*8.0*11.8 (8*2*0) 5.0 4*0.5 (Includes earth) 4*0.5 (Includes earth) 3/8 (.52) 3/4(1.05) *3 1/2(.)* Deluxe Central Controller Front View PCMCIA Slot RS2C Serial Port Back View PC Based Controller A PC based central controller can connect up to 16 CNU and one CNU can connect up to 8 outdoor units(pi5) 2 USE Host Slave Microphone Headphone PC Based Central controller HUB CNU PQNFG00AO CNU PQNFG00AO PMNFP14A0 PI5 PMNFP14A0 PMNFP14A0 Outdoor Unit Indoor Unit 2 3

38 Big Energy Saving with MPS Control MPS (Multi Power System) is a power saving system in which two compressors of different capacities operate at high power until it reaches the preset temperature. After the preset temperature is reached, only the smaller compressor operates, thus saving energy. Power Consumption Comparison Only one compressor operates during low load operations, thus saving power compared to compressors twice the size. Various Indoor Units *Metal(M) all Mounted 100% Conventional(On/Off Operation) Conventional(On/Off Operation) MS0AC N40 MC0AH* NZ1 MC0AH* NE0 MS0AH N40 Indoor Units 40% % MPS Control MPS Control MS0AC N40 MC0AH* NU1 MC0AH* NE0 MA0AC* NP1 MS0AH N40 MA0AH* NP1 MS0AC N40 MCAH* NU1 MCAH* NE0 MAAC* NP1 MS0AH N40 MAAH* NP1 MS0AC N40 MS0AH N MSAC NT0 MSAH MCAH* N MCAH* N Note :* indicates color of panel (M: Metal, R: Mirror, B: Blue, : hite ood, C: Cherry, : ood) *Mirror(R) *Cherry(C) *Silver(V) all Mounted Mirror *Blue(B) % Energy Saving Capa Outdoor Units 14 k Capacity / ()() Input / () Running Current / (A) (ø,v,hz) Refrigerant charge g, type Air Circulation Outdoor CMM(CFM) Noise Level (Sound Pressure,1m) db(a) Pipe Connection Liquid / (mm) Standard Pipe Length (m). Length/Elevation (m) Net Dimensions (xhxd) (mm) Net eight (kg) Stuffing Q y ithout S/Parts (/40ft) Operational Temperature C (Outdoor Unit) C k Capacity / ()() Input / () Running Current / (A) (ø,v,hz) Refrigerant charge g, type Air Circulation Outdoor CMM(CFM) Noise Level (Sound Pressure,1m) db(a) Pipe Connection Liquid / (mm) Standard Pipe Length (m). Length/Elevation (m) Net Dimensions (xhxd) (mm) Net eight (kg) Stuffing Q y ithout S/Parts (/40ft) Operational Temperature C (Outdoor Unit) C k Capacity / ()() Input / () Running Current / (A) (ø,v,hz) Refrigerant charge g, type Air Circulation Outdoor CMM(CFM) Noise Level (Sound Pressure,1m) db(a) Pipe Connection Liquid / (mm) Standard Pipe Length (m). Length/Elevation (m) Net Dimensions (xhxd) (mm) Net eight (kg) Stuffing Q y ithout S/Parts (/40ft) Operational Temperature C (Outdoor Unit) C k Capacity / ()() Input / () Running Current / (A) (ø,v,hz) Refrigerant charge g, type Air Circulation Outdoor CMM(CFM) Noise Level (Sound Pressure,1m) db(a) Pipe Connection Liquid / (mm) Standard Pipe Length (m). Length/Elevation (m) Net Dimensions (xhxd) (mm) Net eight (kg) Stuffing Q y ithout S/Parts (/40ft) Operational Temperature C (Outdoor Unit) C Only M14AC UD0 2,63~4, (,000~,000) 1,0~1,400 ~6. 1,2~0, 1,0 "at.5m", 40(1,4) 5 /.52.5 /.5 801x555x /222 +~+46 MAC UE0 2,051~5, (,000~,000) 80~1,00 ~ 1,2~0, 1,3 "at.5m", 53(1,82) 51 5 /.52.5 /.5 80x655x /11 +~+46 MAC UE0 2,345~6,4 (8,000~,000) 880~2,100 ~.4 1,2~0, 1,0 "at.5m", 53(1,82) 51 5 /.52.5 /.5 80x655x /11 +~+46 MAC UE0 2,6~8,2(,000~,000) 1,100~3,0 ~ 1,2~0, 2,0 "at.5m", 63(2,2) 51/46 5 /.52.5 /.5 80x1,0x /111 +~+46 Heat Pump M14AH UD0 2,55~4,2/2,~4,2 1,3~1,0 / 1,0~1,0 ~6.6/~.0 1,2~0, 1,100 "at.5m", 40(1,4) 5 /.52.5 /.5 801x555x /222 +~+46 ~+ MAH UE0 2,051~5,/2,6~5,803 80~1,00/1,0~1,00 ~/~ 1,2~0, 1,3 "at.5m", 53(1,82) 51 5 /.52.5 /.5 80x655x /11 +~+46 ~+ MAH UE0 2,345~6,4/2,6~6,4 880~2,100/1,3~2,0 ~.4/~.8 1,2~0, 1,0 "at.5m", 53(1,82) 51 5 /.52.5 /.5 80x655x /11 +~+46 ~+ MAH UE0 2,6~8,2/2,~,61 1,100~3,0/1,0~3,0 ~/~1 1,2~0, 2,0 "at.5m", 63(2,2) 51/46 5 /.52.5 /.5 80x1,0x /111 +~+46 ~+ 4 5 *ood(d) *Blue(B) *hite ood() *Mirror(R) *ood(d) *Metal(M) *Blue(B) *hite ood() Notes: 1. Capacities are based on the following conditions: : Indoor Temperature 2 C DB /1 C B, Outdoor Temperature C DB/ C B. : Indoor Temperature C DB / C B, Outdoor Temperature C DB/6 C B 2. Interconnecting Piping Length.5m to each indoor units. 3. Specifications can be changed without notification for improvement. 4. At least two indoor units should be connected.

39 all Mounted Indoor Units NEOPlasma Air Purifying System The NEO PLASMA Air Purifying System developed uniquely by LG not only removes microscopic contaminants and dust, but also removes house mites, pollen, and pet fur to help prevent allergic diseases like asthma. And it also eliminates bad odor by catching odor particle. ith a filter that can be used over and over again by simply using vacuum cleaner, you can enjoy clean fresh air. Auto Cleaning Remove odor & Save time to cleanup (ARTCOOL Mirror) Auto Clean helps to remove odor and save cleanup time. After using airconditioner, Auto Clean ± makes the inner part of Air conditioner dry for min. It removes moisture and mould so you can enjoy odorfree air and save time to clean up. Capacity () all Mounted Mirror 2.1 MS0AH N40 MS0AC N40 MC0AH* NZ1 MC0AH* NE0 MS0AH N40 MS0AC N40 MC0AH* NU1 MC0AH* NE0 MSAH N40 MSAC N40 MCAH* NU1 MCAH* NE0 MSAH N MCAH* N MSAH N MCAH* N MSAH ND0 MSAH ND0 Odor Free! Dust Free! Allergy Free! MA0AH* NP1 MAAH* NP1 Mirror ARTCOOL Panels Odor Removal Efficiency (NH3) Effect of Carbon Nano Ball Deodorizing efficiency:8~10 times compared to conventional carbon filter hat is Carbon Nano Ball? Nano(1/1Bil) ball structure, (0~0nm) consisted of carbon, is adopted as deodorizing material first in the world After Operation, Start AutoClean automatically In minutes AutoClean makes the inner part of Air conditioner dry Jet Cool TM Jet cool function is for quick cooling. In this mode, strong and cool air is blown at high speeds for minutes until the room temperature reaches to oc. Gallery Specifications Capacity kcal/h() Capacity kcal/h() Air Circulation CMM(CFM) Noise Level(Sound Press,1m) H/M/L dba Dimensions *H*D mm Net eight kg Liquid Piping Connection Drain hose (ID ø ) mm Stuffing Quantity ithout S/Parts /40ft MS0AH N40 MS0AH N40 MSAH N40 MSAH N MSAH N MSAH ND0 MSAH ND0 MA0AH* NF0 MAAH* NF0 1,64 (2,051),000 2,016 (2,343) 8,000 2 / / 58*2*1 3/8 (.52) 440/10 MA0AH* NF0 2,26 (2,6),000 2,5 (2,2) 10,000 / 2 / 22 58*2*1 3/8 (.52) 440/10 3,0 (3,5),000 3,6 (3,86) 13,0.0 / / 2 58*2*1 3/8 (.52) 440/10 MAAH* NF0 Note : * indicates color of panel *Metal(M) *Mirror(R) *Silver(V) *Red(E) *Gold(G) *hite Silver(H) *ood(d) *Blue(B) *Mirror(R) *Cherry(C) *hite ood() *Blue(B) *ood(d) *Metal(M) *Blue(B) *hite ood() *Gallery(1) 4,5 (5,),000 4,0 (5,803) 1,800 3 / 34 / 1,00*0*0 13 1/2 (.) /558 5,6 (6,40) 23,000 6,426 (,42),0 41 / 3 / 34 1,00*0*0 13 1/2 (.) /558,5 (8,0),000 8,3 (,),000 / 45 / 41 1,*346*5 1 5/8 (.88) 168/0,00 (10,5),000,80 (11,0) 3, / / 44 1,*346*5 1 5/8 (.88) 168/0 2,26 (2,6),000 2,5 (2,2) 10,000.5(264) 3 / / 2 0*0*146 3/8 (.) 0/510 3,0 (3,5),000 3,6 (3,6) 13,0 (0) 43 / 3 / 0*0*146 3/8 (.) 0/510 6 *Metal(M) *Mirror(R) *ood(d) *ood(d) *Metal(M) *hite Silver *Red MC0AH* NZ1 MC0AH* NE0 MC0AH* NU1 MC0AH* NE0 MCAH* NU1 MCAH* NE0 MCAH* N MCAH* N MA0AH* NP1 MAAH* NP1 *Blue(B) *Cherry(C) *Silver(V) *hite ood() *Mirror(R) *Blue(B) *Blue(B) *hite ood() *Gold *Silver Capacity kcal/h() Capacity kcal/h() Air Circulation H/M/L CMM(CFM) Noise Level (Sound Press,1m) H/M/L dba I/h Dimensions *H*D mm Net eight kg Liquid Piping Connection Drain hose (IDø ) Stuffing Quantity ithout S/Parts /40ft 1,64 (2,051),000 2,016 (2,343) 8,000 (14) / 2/ *22*143 (1.) 3/8 (.52) 340/ 1,64 (2,051),000 2,016 (2,343) 8,000 (14) / / 1.0 *2*165 (1.) 3/8 (.52) 2,26 (2,6),000 2,5 (2,2) 10,000 (0) / / ,0**3.5 (.) 3/8 (.52) 3/684 2,26 (2,6),000 2,5 (2,2) 10,000 (0) / 26 / *2*165.5 (.) 3/8 (.52) 3,0 (3,5),000 3,6 (3,86) 13,0.0 (3) / / ,0**3.5 (.) 3/8 (.52) 3/684 3,0 (3,5),000 3,6 (3,86) 13,0.0 (3) / / 1.5 *2*165.5 (.) 3/8 (.52) 4,5 (5,),000 4,0 (5,803) 1, (45) 3 / 3/ 2.0 1,10*3*13 13 (.) 1/2 (.) 234/45 5,6 (6,40) 23,000 6,426 (,42),0 14 (44) 43 / 41 / 1,10*3*13 13 (.) 1/2 (.) 234/45 2,26 (2,6),000 2,5 (2,2) 10,000.5 (264) 3 / / *568* (1.84) 3/8 (.52) 0/0 3,0 (3,5),000 3,6 (3,86) 13,0 (0) 43 / 3 / 1.4 *568* (1.84) 3/8 (.52) 0/0

40 Ceiling Cassette Indoor Units Application of a High Efficiency Compact Turbo Fan The application of a compact turbo fan minimized the size of the interior device and increased the installation stability as well as the space beauty. It also has improved the air flow and the interior temperature distribution to the optimal conditions, forming a quiet and pleasant environment. Super Slim Design The interior air conditioner with the smallest and the most compact design in the world based on a threedimensional CAD and CAE computer system has successfully reduced the space it occupies and enabled installation in various spaces (TH window frames) 2mm BLDC Inverter Motor The variable range of interior air has been increased up to ~1% by using a superlight BLDC inverter. It also has increased the stability and efficiency of the product, and realized even more pleasant air conditioning with reduced noise level of db when the product is running for subtle breezes. Variable range of wind of the interior fan motor db Preestablished AC Motor Capacity () 1ay Cassette 4ay Cassette Specifications.0 MT0AH NC1 MT11AH NC1 MT10AH NE1 MTAH NE1 MTAH NE1 MTAH NH0 MTAH NF0 MTAH ND0 BLDC Inverter Motor Inverter Motor MT0AH NC1 MT11AH NC1 MT10AH NE1 MTAH NE1 MTAH NE1 MTAH NH0 MTAH NF0 MTAH ND0 Ceiling Cassette 1way Ceiling Cassette 4way Compact Turbo Fan Testing Ponint Low Air flow rate PLASMA Air Purifying System (Optional) LG's unique PLASMA Air Purifying System not only reduces microscopic contaminants and dust, but also filters house mites, pollen and even pet fur to ease allergy and asthma symptoms. ith a filter that can be used over and over again by simply washing it, you can enjoy clean fresh air without having to worry about changing the filter every couple of years or so resulting in cost savings. Cover Heat exchangers highefficiency turbine fans front panels highperformance antibacterial filters Filter Cover Long Distance, High Elevation Piping LG air conditioners (cassette and concealed duct models) can be installed for long distance (up to m) and high elevation applications (up to m). subtle breezes weak wind medium wind strong wind powerful wind 0% 0% 100% 110% 1% Super Low Power Consumption Use in Standby Mode by Adopting SMPS windamount mode operational range (Switching Mode ) Power waste due to standby power Power is wasted if a plug is connected to an outlet even though the appliance is turned off. Development of super powersaving SMPS (Switching Mode ) Zero standby power by reducing 0% of standby power. No need to pull out every plug when system is not in use. Capacity kcal/h() Capacity kcal/h() Air Circulation H/M/L CMM(CFM) Noise Level(Sound Press,1m) H/M/L dba Dimensions (*H*D) Indoor Unit mm Decorative Panel mm Net eight Body kg(lbs) Panel kg(lbs) Liquid Piping Connection Drain hose (IDø) Stuffing Quantity ith(ithout) S/Parts /40ft 2,26 (2,6),000 2, 5 (2,2) 10,000 /.5/ (0/265/2) / / 1.1 8*0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 3,0 (3,5),000 3,6 (3,86) 13,0.5/8/ (3/3/) 3 / / *0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 2,26 (2,6),000 2, 5 (2,2) 10,000 /.5/ (0/265/2) / / 1.1 8*0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 2,26 (2,6),000 2, 5 (2,2) 10,000 /.5/ (0/265/2) / / 1.1 8*0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 2,26 (2,6),000 2, 5 (2,2) 10,000 /.5/ (0/265/2) / / 1.1 8*0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 2,26 (2,6),000 2, 5 (2,2) 10,000 /.5/ (0/265/2) / / 1.1 8*0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 2,26 (2,6),000 2, 5 (2,2) 10,000 /.5/ (0/265/2) / / 1.1 8*0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 2,26 (2,6),000 2, 5 (2,2) 10,000 /.5/ (0/265/2) / / 1.1 8*0* 1,0**0 22 (4) 4 () 3/8 (.52) 1.26 () 261/534 (263/53) 8

41 Ceiling Concealed Duct Indoor Units Capacity () Builtin Low Static Slim Duct High Static E.S.P: External Static Pressure Always air volume and sound kept as design regardless of E.S.P change Using this technology, you can Optimize duct work Installation Keep capacity & sound level as desired Simplify model numbers The phase control motor technology gives benefit of saving money to Installer.Desired air volume is obtained by controlling the phase of motor while installing the product and this makes your duct work system flexible. E.S.P is controlled from 0 to 10mmAq. Air volume H M L Air volume at 2 mmaq H M L Air volume at 10 mmaq Static pressure(mmaq) *Notes: MBAH, MBAH, MBAH, MBAH MB0AHB NP0 MB0AHL NT0 MB0AHL N10 MBAHB NP0 MBAHL NT0 MBAHL N10 MBAHL NT0 MBAHL N MBAH NH0 Slim duct Hidden in the ceiling, this product is suitable for applications that require floor level or individual level air conditioning for buildings where there are many rooms or halls, such as restaurants, concert halls and hotels. Installation is not hindered by the location of lighting fixtures or room structure, and interior renovation is made easy with the installation of various ventilation diffusers. MB0AHL N10 Slim Duct *Conventional : 6x2x5 MBAHL N Noise Level 10mm 8x10x5 (4%) Inverter Fan Motor MB0AHL N10.0 MBAH NH0 MBAH NG0 MBAH NG0 Specifications Capacity kcal/h() Capacity kcal/h() Air Circulation H/M/L CMM(CFM) Noise Level H/M/L dba I/h Dimensions Indoor(*H*D) mm Panel(*H*D) mm Net eight Indoor kg Panel kg Piping Connection Liquid Drain hose (ID ø) Stuffing Quantity ithout S/Parts /40ft Capacity kcal/h() Capacity kcal/h() Air Circulation H/M/L CMM(CFM) Noise Level H/M/L dba I/h Dimensions Indoor(*H*D) mm Net eight Indoor kg Piping Connection Liquid Drain hose (ID ø) Stuffing Quantity ithout S/Parts /40ft Capacity kcal/h() Capacity kcal/h() Air Circulation H/M/L CMM(CFM) Noise Level H/M/L dba I/h Dimensions Indoor (*H*D) mm Net eight kg Piping Connection Liquid Drain hose (ID ø) Stuffing Quantity ithout S/Parts /40ft Capacity kcal/h() Capacity kcal/h() Air Circulation H/M/L CMM(CFM) Noise Level H/M/L dba I/h Dimensions Indoor (*H*D) mm Net eight kg Piping Connection Liquid Drain hose (ID ø) Stuffing Quantity ithout S/Parts /40ft MB0AHB NP0 1,168 (2,63),000 2,5 (2,) 10, /10/ (406/3/0) 34 / / 1.0 *0*580 65*5* 6 3/8 (.52) 2 2/468 MB0AHL NT0 2,268 (2,63),000 2,5 (2,) 10,000 8//6 (2/6/1) 34 / / 1.0 6*2*5 22 3/8 (.52) 2 /6 MB0AHL N10 2,268 (2,63),000 2,5 (2,) 10,000 8//6 (2/6/1) / 26 / 1.0 8*10* /8 (.52) 2 2 / 8 MBAH NH0 4,5 (5,),000 4,0 (5,803) 1,800 1/14.5/13 (583/5/45) / 34 / *2*4 1/2 (.) 2 0/2 Ceiling Concealed Duct Builtin Ceiling Concealed Duct Low Static MBAHL NT0 3,0 (3,516),000 3,6 (3,868) 13,000 10//8 (2//2) 3 / 34 / 1.2 6*2*5 22 3/8 (.52) 2 /6 Ceiling Concealed Duct Slim Duct MBAHL N10 MBAHL N 3,0 (3,516) 4,5 (5,),000,000 3,6 (3,868) 4,8(5,802) 13,000 1,800 1//10 (4/4/3) 1//10 (4/4/3) / / / / *10* *10* /8 (.52) 1/2 (.) / / 6 Ceiling Concealed Duct High Static MBAH NH0 MBAH NG0 6,0 (,034),5 (8,1),000,000 6,653 (,3) 8,6 (,) 26, /1/14 (6/583/44) 2/23/ (/8/06) //34 40 / / 880*2*4 10**4 1/2 (.) 5/8 (.88) 2 2 0/2 5/11 MBAHB NP0 3,0 (3,5),000 3,6 (3,868) 13,0 11.5/10/ (406/3/0) / / 1.2 *0*580 65*5* 6 3/8 (.52) 2 2/468 MBAHL NT0 4,5 (5,),000 4,0 (5,802) 1,800 1//10 (4/4/3) / / ,000*2*5 2 3/8 (.52) 2 3/1 MBAHL N 4(0), (3) 26, /16/ (6/565/52) 3 / 34 / *10*55 1/2 (.) / 6 MBAH NG0,02 (10,),000 (114) 3,0 /2/26 (11/10/) 42 / 3 / 10**4 5/8 (.88) 2 5/

42 Ceiling & Floor Indoor Units Upgraded Function One Touch Filter & Filter Cleaning Alarm Function Power ind Mode ired Remote Controller (Option) eekly Program Group control. etc Airflow Direction Control Horizontal Airflow Direction Control. Adjust the horizontal airflow direction by manually moving the horizontal airflow direction louver by hand. Gold Fin TM Anti Corrosion LG s Outdoor Heat Exchanger is coated with a golden anticorrosive epoxy treatment on the aluminum coil to minimized corrosion. This maintains heat transfer properties of the coil for an extended time where as nongold Fin coils progressively lose efficiency due to surface corrosion. Standard on every LG air conditioner, this assists in areas suffering from pollution or near the ocean where the unit may subjected to higher levels of salt. [Test Standard : ASTM B11, KS D2] Vertical Airflow Direction Control The airflow direction can be adjusted as desired by using the remote controller. Horizontal Capacity () Ceiling & Floor Specifications Capacity kcal/hr() r Capacity kcal/hr() Air Circulation H/M/L CMM(CFM) Noise Level H/M/L dba I/h Dimensions Indoor (*H*D) mm Net eight kg(lbs) Liquid Piping Connection Drain hose (ID ø) Stuffing Quantity ith(ithout) S/Parts /40ft.0 MV0AH NE0 MVAH NE0 MVAH NE0 MVAH NE0 MV0AH NE0 2,268 (2,63),000 2,5 (2,) 10,000.8/6.4/5.0 (26/226/1) / / *0*40 (2) 3/8 (.52) /3 Ceiling & Floor MVAH NE0 MVAH NB0 3,0 (3,516) 4,5 (5,),000,000 3,6 (3,86) 4,0 (5,801) 1,000 1, /8.3/ (3/23/2) 1//11(4/4/8) 40 / / 43 / 40 / *0*40 1,0*5*6 (2) (6) 3/8 (.52) 1/2 (.) /3 102/ MVAH NB0 6,0 (,0),000 6,3 (,4),0 /1/ (5/4/4) 45 / 42 / 3 3 1,0*5*6 (6) 1/2 (.) 102/ Downward 82 83

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG. Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications

More information

(Non-Inverter & Inverter) R410A

(Non-Inverter & Inverter) R410A LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER AIR CONDITIONER manufactured with latest inverter Technology 97% of operating power from solar energy very low Power consumption levels Eco-friendly, reduced

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

/ airconditioning

/ airconditioning AUSRAC081 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 0288054000 FAX : 02880541 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 0739089000 FAX : 0733994179 Victoria

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. R COOL EER 0V ~ 50Hz 1Ph HEAT COP Heat Pump High Wall Split Systems 1K - 18K - 4K 0K - 6K Plasma Green Plasma Green Technology 1K-18K-4K Tropical Compressor

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

Ducted inverter reverse cycle air conditioning

Ducted inverter reverse cycle air conditioning Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling

More information

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning

More information

Amena s Globo series are a group of air conditioning products designed for markets where maximum

Amena s Globo series are a group of air conditioning products designed for markets where maximum mena s Globo series are a group of air conditioning products designed for markets where maximum ambient temperatures are not more than 43 C. These products are available in both cooling only and heatpump

More information

FUJITSU FLOOR CONSOLES FUJITSU

FUJITSU FLOOR CONSOLES FUJITSU FUJITSU FLOOR CONSOLES Fujitsu s latest technology delivers powerful yet very efficient heating in these smart floor standing heat pumps. FUJITSU Better Heat Better efficiency Heat GuaranteeD WHAT IS FUJITSU

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

Split System Air Conditioning

Split System Air Conditioning Split System Air Conditioning Transforming global energy-efficiency into an art form! Contents DC Inverter Technology 4 Braemar's superior performance 5 Inverter control display functions 6 Inverter control

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 2010 Air Conditioning System 2010 Air Conditioning System Enjoy a clean

More information

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz] PLXSPH1502 Floor Standing FV Series Dealer Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia http://www.daikin.com/global_ac/

More information

Multi split Inverter

Multi split Inverter Multi split Inverter Conditioning in all home environments air conditioning the silence ith the Fujitsu DC Inverter conditioning units you will enjoy maximum comfort throughout your home. Discover the

More information

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning

More information

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Ductless Mini-Split Systems. Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 60 years of experience, exporting to more than 120 countries around the world,

More information

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU ONLY PANASONIC GETS 5 STARS AGAIN, AGAIN & AGAIN AIR CONDITIONING AERO SERIES REVERSE-CYCLE INVERTER Reliability Functionality Ease of use Value for money After sales service Overall customer satisfaction.

More information

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING A Better Life. A Better World Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without

More information

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden

More information

Inverter Ducted XPower 42QSS

Inverter Ducted XPower 42QSS 3D DC Inverter Timer Sleep Mode Turbo Mode Auto Leak Detection 49 Compact and versatile is the ideal choice for new or refurbished buildings Key Features EUROVENT CERTIFIED PERFORMANCE: Eurovent Certification

More information

Inverter console UFV system. Compact design and personalised air flow selection

Inverter console UFV system. Compact design and personalised air flow selection Inverter console UFV system Compact design and personalised air flow selection 2 Efficient and reliable system Thanks to Toshiba DC Hybrid Inverter technology the system operates at maximum capacity in

More information

RC-0219-A. Single-Split Non Inverter Series

RC-0219-A. Single-Split Non Inverter Series TM RC-0219-A Single-Split Non Inverter Series R32 The Superior Refrigerant This game changing refrigerant strikes the perfect balance between energy efficiency, ease of use and environmental sustainability;

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can

More information

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Today, the air is perfect. Perfect temperature. Perfect humidity. Perfectly clean and fresh,

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 200 Air Conditioning System 200 Air Conditioning System Enjoy a clean

More information

AIR CONDITIONING REVERSE-CYCLE INVERTER

AIR CONDITIONING REVERSE-CYCLE INVERTER AIR CONDITIONING REVERSE-CYCLE INVERTER CLASS LEADING FEATURES FASTER COOLING The new Panasonic Thermal Enhancement Technology (P-TECh) enables the compressor to achieve maximum frequency in the shortest

More information

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool Air Conditioning Product Brochure 2015/2016 Classic Series Hi-Wall Split Systems Everyday Cool 3 Everyday Innovation We design with you in mind. You ll find that Haier Air Conditioning units are quiet,

More information

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS 17 SEER 9.0 HSPF / 11.5 EER HEAT PUMP AND COOLING ONLY Elegant and stylish wall mounted unit providing high efficiency and comfort DSS Series single-zone

More information

Reverse Cycle Split Systems DC Inverter & Fixed Speed

Reverse Cycle Split Systems DC Inverter & Fixed Speed Reverse Cycle Split Systems DC Inverter & Fixed Speed Think of the biggest air conditioning brands in Australia. Well, Midea is bigger than any of them - in fact it s probably bigger than all of them put

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Samsung Free Joint Multi Air Conditioning System

Samsung Free Joint Multi Air Conditioning System Samsung Free Joint Multi Air Conditioning System Air Conditioning solutions from a brand you can rely on At the heart of family living is the home, a place full of special moments and wonderful memories

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can be made up

More information

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR Comfort We offer a wide range of products, and always provide you with

More information

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. Kaden Ducted Air Conditioners Creating the ideal climate in different rooms throughout your home is essential for your family s comfort. Whether it s a

More information

SAMSUNG SPLIT AIR CONDITIONER MAX PLUS

SAMSUNG SPLIT AIR CONDITIONER MAX PLUS SAMSUNG SPLIT AIR CONDITIONER MAX PLUS Rating: t Rated Yet Price? 2,250.00 Ask a question about this product Description Triangle Design For Powerful Cooling The Samsung Air Conditioner s unique triangular

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS Now Only One Unit Required for Initial Start-up L Multi Zone Inverter Heat Pump High Efficiency Multi 21+ heat pump units can heat and cool up to 5 zones without

More information

Mitsubishi System Technologies:

Mitsubishi System Technologies: Mitsubishi System Technologies: commercial, institutional and large residential personalized comfort solution. (P-Series systems) Mitsubishi Electric delivers flexible and convenient cooling and heating

More information

Samsung Room Air Conditioning

Samsung Room Air Conditioning Samsung Room Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

Inventor of the Inverter Digital Inverter System

Inventor of the Inverter Digital Inverter System Inventor of the Inverter Digital Inverter System Inventor of the Inverter The Digital inverter from Toshiba combines economy and ecology in a smart body. It offers state-of-the-art technology, exceptional

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

HI-WALL SPLIT SYSTEMS

HI-WALL SPLIT SYSTEMS HI-WALL SPLIT SYSTEMS What you ll find inside: Technology Digital Inverter range Controllers Product specifications Effective air filtration Energy efficient Heating & cooling 1 Toshiba Air Conditioning.

More information

Inverter Wall Mounted

Inverter Wall Mounted Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

ENGiNEERiNG AND SPECiFiCATioNS GuiDE ENGiNEERiNG AND SPECiFiCATioNS GuiDE DuCT-FREE AiR CoNDiTioNiNG SySTEmS ART CooL inverter FLEx multi-split FLooR STANDiNG CEiLiNG CASSETTE PTAC PTHP THRouGH-THE-WALL LG Electronics, Air Conditioning Division

More information

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Packaged Roof Top Air Conditioners Product Review OPA-RK Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.6 kw 137 kw MEPS COMPLIANT INVERTER MODEL MODELS MARCH 2014

More information

Braemar superior range of reverse cycle air conditioning

Braemar superior range of reverse cycle air conditioning Braemar superior range of reverse cycle air conditioning Frank Seeley AM FAICD Founder and Executive Chairman. For more than 40 years, Seeley International has been creating world leading air conditioning

More information

Single "A" Air Conditioner SVC MANUAL(General)

Single A Air Conditioner SVC MANUAL(General) Internal Use Only http://biz.lgservice.com Single "A" Air Conditioner SVC MANUAL(General) MODEL : Single "A"-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General SVC

More information

Now with WiFi as standard Find out more at

Now with WiFi as standard Find out more at Floor Console Now with WiFi as standard Find out more at www.greeonline.com (SMPS model) Power Saving Technology GREE Sine-Wave DC Inverter technology allows a room to reach the required temperature more

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring: Ozone Friendly Refrigerant Variable Compressor Speed Ductless Split Systems Featuring: Ozone Friendly Refrigerant Variable Compressor Speed Technology IAQ Catechin Plus Air Purifying System 13 to 17 SEER

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Inverter Wall Mounted

Inverter Wall Mounted PLXRHK1603 Inverter Wall Mounted FTKS-A Series COOLING ONLY What is inverter technology? Inverter system ensures faster cooling with signifi cant energy saving. Moreover, it helps to maintain consistent

More information

Pure Efficiency Meets Healthy Living NEW 2013

Pure Efficiency Meets Healthy Living NEW 2013 Pure Efficiency Meets Healthy Living NEW 2013 MILD DRY AUTOCOMFORT NEW 2013 nano technology cleaner perfect humidity control s improved comfort 20 db * *May apply to certain models only KIT PAN-XE9N PAN-XE12N

More information

Wall Mounted Split Systems G-Series AP - MWM - G - 06A

Wall Mounted Split Systems G-Series AP - MWM - G - 06A Wall Mounted Split Systems G-Series AP - MWM - G - 06A Air Purifying System Negative Ion Generator (Standard) The Ion Generator releases negative ion shower to create a refreshing and clean environment

More information

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models T-Class Performance and rugged durability Commercial Split Systems Up to 20-Ton TSA/TPA Models Up to.7 EER Lennox units deliver comfort and control you can depend on Lennox proven design in air conditioners

More information

PLXSID1605. Warning HEAD OFFICE :

PLXSID1605. Warning HEAD OFFICE : Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS 2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS Midea Company Profile Established in 1968, Midea Group has grown into a leading consumer appliances and HVAC systems manufacturer. With over 8,000 employees,

More information

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR FTQ SERIES DUCTED HEAT PUMP SYSTEMS INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR FTQ SERIES DUCTED HEAT PUMP SYSTEMS LEADING TECHNICAL PERFORMANCE

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient

More information

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Concealed Duct Heat Pumps Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH

More information

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS WALL-MOUNTED UNITS Up to 19 SEER / Up to 9.0 HSPF / Up to 12.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR 19 Series Discreet wall-mounted unit providing

More information

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15 Midea VRF (V+) V+S (Heat Pump) V+i (Individual) (Heat Pump) V+R (Heat Recovery) MVRF 05/5 Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit

More information

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series FSKMIF-71AE2-EU FSKMIF-91AE2-EU FSKIF-121AE2-EU FSKMI-181AE2-EU FSLMIF-71AE2 FSLMIF-91AE2 FSLIF-121AE2 FSLMI-180AE2

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

MONO & MULTI SPLIT AIR CONDITIONERS

MONO & MULTI SPLIT AIR CONDITIONERS MONO & MULTI SPLIT AIR CONDITIONERS SINGLE SPLIT DCI INVERTER TECHNOLOGY Low Consumption Low Noise Level Precise temperature set ENERGY CLASS IR REMOTE Standby 0,5W 3 Sleep Curve Comfortable Cold Air Prevention

More information

World s best airconditioning

World s best airconditioning World s best airconditioning Energy Efficient Environmentally Preferable Non Toxic Pioneer Pro Series DC High Static Ducted 1 st IN CLASS Non-toxic Eco-friendly The Pioneer Pro employs inverter technology

More information

Product Brochure Smart Power. Low Profile Ducted

Product Brochure Smart Power. Low Profile Ducted Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers

More information