1 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF

2 OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP OUTDOOR UNIT LINEUP 6k 7k 9k 12k 15k 19k 24k 27k 30k 34k 38k 42k 48k 55k 68k 85k 96k 136k 154k One-way cassette Two-way cassette Cassette Four-way cassette Compact four-way cassette Low static pressure Duct Medium static pressure High static pressure Fresh air processing unit Wall mounted Ceiling & floor Notes: Fresh air processing unit is not available for V4+R and Mini VRF Series

3 OUTDOOR UNIT LINEUP OUTDOOR UNIT LINEUP OUTDOOR UNITS VRF V4 PLUS SYSTEM 11 12

4 OUTDOOR UNIT LINEUP Indoor Units VRF V4 Plus indoor units High EER and COP Values OUTDOOR UNIT LINEUP V4 Plus S Series equipped with all DC compressors, all DC fan motors and high efficient heat exchanger. The cooling EER is up Fresh Air Processing Unit to 4.29 and the heating COP is up to 4.39 in the 8HP category. 100 fresh air supply Ventilation Heat recovery ventilator (HRV) EER COP AHU Connection Kit Connect to other brand AHU Control Systems Smart control systems 8HP 10HP 12HP 14HP 16HP 18HP 8HP 10HP 12HP 14HP 16HP 18HP VRF V4 Plus S Series Long Piping Length Heat Pump Total piping length 1000m 3280ft. Optimized design for small to large buildings ALL DC inverter compressors ALL DC fan motors Capacity up to 72HP Connectable indoor units quantity up to 64 ESP up to 60Pa Cycle duty operation Backup operation Precise oil control technology Longest actual piping length 175m 90m Level difference between IDU~ODU 110m Level difference between IDU~IDU 30m Longest length actual (Equivalent) Longest length after first branch Level difference between indoor and outdoor units - ODU up (down) Level difference between indoor units 175(200)m 90*m 70(110)m 30m 574(656)ft. 295*ft. 230(361)ft. 98ft. *The longest piping length is 40m(131ft.) standard. It can be extended to 90m(295ft.). When the length is over 40m(131ft.), please contact your local TGM dealer for more information and restrictions. Advanced silence technology Intelligent defrosting technology Simple communication wiring Auto addressing Easy maintenance 13 14

5 OUTDOOR UNIT LINEUP VRF V4 Plus S Series - Heat Pump 380~415V-60Hz 220V-60Hz HP MDV- MDV- Cooling Heating Connectable indoor unit Compressor Fan motor Refrigerant ~415V 252(8)WD2CN1(B) 280(10)WD2CN1(B)335(12)WD2CN1(B)400(14)WD2CN1(B)450(16)WD2CN1(B)500(18)WD2CN1(B) 220V 252(8)WD2DN1(B) 280(10)WD2DN1(B)335(12)WD2DN1(B)400(14)WD2DN1(B)450(16)WD2DN1(B)500(18)WD2DN1(B) VPhHz & Capacity k EER Capacity k COP Total capacity 50~130 of outdoor unit capacity Max. quantity Type DC inverter Quantity Type DC motor Quantity Pa(in. W.G.) 0-20(0-0.08) (default) Static pressure Pa(in. W.G.) 0-40(0-0.16) (customized) 0-60(0-0.24) (customized) 0-40(0-0.16) (customized) Type R410A Factory charging (380~415V) kg(lbs.) 10(22) 10(22) 12(26) 15(33) 15(33) 16(35) Factory charging (220V) kg(lbs.) 9(20) 9(20) 11(24) 13(29) 13(29) 16(35) Liquid pipe Φ12.7(Φ12) Φ12.7(Φ12) Φ15.9(Φ58) Φ15.9(Φ58) Φ15.9(Φ58) Φ19.1(Φ34) Gas pipe Φ25.4(Φ1) Φ25.4(Φ1) Φ31.8(Φ1-14) Φ31.8(Φ1-14) Φ31.8(Φ1-14) Φ31.8(Φ1-14) Pipe connections Oil balance pipe Φ6(Φ14) Air flow rate m 3 h Sound pressure level db(a) Net dimension (W H D) mm inch Packing size (W H D) mm inch Net weight 380~415V kg(lbs.) 212(466) 212(466) 288(634) 288(634) 288(634) 310(682) 220V kg(lbs.) 202(444) 202(444) 285(627) 285(627) 288(634) 310(682) Gross weight 380~415V kg(lbs.) 227(499) 227(499) 308(678) 308(678) 308(678) 330(726) 220V Operating temperature range kg(lbs.) C( F) 218(480) 218(480) 305(671) 305(671) Cooling: -5-48(23~118.4); Heating: (-4~75.2) 308(678) 330(726) VRF V4 Plus S Series - Heat Pump 380~415V-60Hz 220V-60Hz HP MDV- MDV- Combined type Cooling Capacity 380~415V 220V VPhHz k (30)WD2CN1(B) 850(30)WD2DN1(B) 14HP+16HP (32)WD2CN1(B) 900(32)WD2DN1(B) 14HP+18HP (34)WD2CN1(B) 950(34)WD2DN1(B) 16HP+18HP & (36)WD2CN1(B) 1000(36)WD2DN1(B) 18HP EER Heating Capacity k COP Connectable Total capacity 50~130 of outdoor unit capacity indoor unit Max. quantity Compressor Type DC inverter Quantity 4 Fan motor Type DC motor Quantity 4 Refrigerant Type R410A Factory charging (380~415V) kg(lbs.) 15 2(33 2) 15+16(33+35) 15+16(33+35) 16 2(35 2) Factory charging (220V) kg(lbs.) 13 2(29 2) 13+16(29+35) 13+16(29+35) 16 2(35 2) Pipe Liquid pipe Φ19.1(Φ34) Φ19.1(Φ34) Φ19.1(Φ34) Φ19.1(Φ34) connections Gas pipe Φ31.8(Φ1-14) Φ31.8(Φ1-14) Φ38.1(Φ1-12) Φ38.1(Φ1-12) Oil balance pipe Φ6(Φ14) Φ6 Air flow rate m 3 h Sound pressure level db(a) 64 Net dimension (W H D) mm ( ) 2 Packing size (W H D) mm ( ) 2 Net weight 380~415V kg(lbs.) 288 2(634 2) ( ) ( ) 310 2(682 2) 220V kg(lbs.) ( ) ( ) ( ) 310 2(682 2) Gross weight 380~415V kg(lbs.) 308 2(678 2) ( ) ( ) 330 2(726 2) 220V kg(lbs.) ( ) ( ) ( ) 330 2(726 2) Operating temperature range C( F) Cooling: -5-48(23~118.4); Heating: (-4~75.2) (38)WD2CN1(B) 1060(38)WD2DN1(B) 10HP 2+18HP ( ) ( ) Φ19.1(Φ34) Φ38.1(Φ1-12) ( ) 2+( ) ( ) 2+( ) ( ) ( ) ( ) ( ) OUTDOOR UNIT LINEUP HP MDV- MDV- Combined type Cooling Heating Connectable indoor unit Compressor Fan motor Refrigerant Pipe connections Air flow rate Sound pressure level Net dimension (W H D) Packing size (W H D) Net weight Gross weight ~415V 560(20)WD2CN1(B) 615(22)WD2CN1(B) 680(24)WD2CN1(B) 730(26)WD2CN1(B) 780(28)WD2CN1(B) 220V 560(20)WD2DN1(B) 615(22)WD2DN1(B) 680(24)WD2DN1(B) 730(26)WD2DN1(B) 780(28)WD2DN1(B) 10HP 2 10HP+12HP 10HP+14HP 10HP+16HP 10HP+18HP Capacity VPhHz & k EER Capacity k COP Total capacity 50~130 of outdoor unit capacity Max. quantity Type DC inverter Quantity Type DC motor Quantity Type R410A Factory charging (380~415V) kg(lbs.) 10(22) (22+26) 10+15(22+33) 10+15(22+33) 10+16(22+35) Factory charging (220V) kg(lbs.) 9(20) (20+24) 9+13(20+29) 9+13(20+29) 9+16(20+35) Liquid pipe Φ15.9(Φ58) Φ15.9(Φ58) Φ15.9(Φ58) Φ19.1(Φ34) Φ19.1(Φ34) Gas pipe Φ28.6(Φ1-18) Φ28.6(Φ1-18) Φ28.6(Φ1-18) Φ31.8(Φ1-14) Φ31.8(Φ1-14) Oil balance pipe Φ6(Φ14) m 3 h db(a) mm ( ) 2 ( )+( ) mm ( ) 2 ( )+( ) 380~415V kg(lbs.) 212 2(466 2) ( ) ( ) ( ) ( ) 220V kg(lbs.) 202 2(444 2) ( ) ( ) ( ) ( ) 380~415V kg(lbs.) 227 2(499 2) ( ) ( ) ( ) ( ) 220V kg(lbs.) 218 2(480 2) ( ) ( ) ( ) ( ) Operating temperature range C( F) Cooling: -5-48(23~118.4); Heating: (-4~75.2) Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27 C(80.6 F) DB19 C(66.2 F) WB; Outdoor temperature 35 C(95 F) DB24 C(75.2 F) WB. Heating: Indoor temperature 20 C(68 F) DB15 C(59 F) WB; Outdoor temperature 7 C(44.6 F) DB6 C(42.8 F) WB. Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m(295ft.). If the total equivalent liquid length is more than 90m(295ft.), please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position of 1m(3.28ft.) in front of the unit and 1.3m(4.26ft.) above the floor. HP MDV- MDV- Combined type Cooling Capacity 380~415V 220V VPhHz k (40)WD2CN1(B) 1130(40)WD2DN1(B) 10HP+14HP+16HP (42)WD2CN1(B) 1180(42)WD2DN1(B) 10HP+16HP (44)WD2CN1(B) 1230(44)WD2DN1(B) 10HP+16HP+18HP & (46)WD2CN1(B) 1280(46)WD2DN1(B) 10HP+18HP EER Heating Capacity k COP Connectable Total capacity 50~130 of outdoor unit capacity indoor unit Max. quantity 64 Compressor Type DC inverter Quantity 4 Fan motor Type DC motor Quantity 4 Refrigerant Type R410A Factory charging (380~415V) kg(lbs.) ( ) ( ) ( ) ( ) Factory charging (220V) kg(lbs.) ( ) ( ) ( ) ( ) Pipe Liquid pipe connections Gas pipe Oil balance pipe Φ6(Φ14) Air flow rate m 3 h Sound pressure level db(a) 64 Net dimension (W H D) mm ( ) 2 Packing size (W H D) mm ( ) 2 Net weight 380~415V kg(lbs.) ( ) ( ) ( ) ( ) 220V kg(lbs.) ( ) ( ) ( ) ( ) Gross weight 380~415V kg(lbs.) ( ) ( ) ( ) ( ) 220V kg(lbs.) ( ) ( ) ( ) ( ) (48)WD2CN1(B) 1350(48)WD2DN1(B) 14HP+16HP+18HP Operating temperature range C( F) Cooling: -5-48(23~118.4); Heating: (-4~75.2) Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27 C(80.6 F) DB19 C(66.2 F) WB; Outdoor temperature 35 C(95 F) DB24 C(75.2 F) WB. Heating: Indoor temperature 20 C(68 F) DB15 C(59 F) WB; Outdoor temperature 7 C(44.6 F) DB6 C(42.8 F) WB. Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m(295ft.). If the total equivalent liquid length is more than 90m(295ft.), please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position of 1m(3.28ft.) in front of the unit and 1.3m(4.26ft.) above the floor ( ) ( ) ( ) ( ) ( ) ( ) 15 16

6 OUTDOOR UNIT LINEUP VRF V4 Plus S Series - Heat Pump 380~415V-60Hz 220V-60Hz HP MDV- MDV- Combined type Cooling Heating Connectable indoor unit Compressor Fan motor Refrigerant Pipe Liquid pipe connections Gas pipe Oil balance pipe Air flow rate Sound pressure level Net dimension (W H D) Packing size (W H D) Net weight Gross weight ~415V 1400(50)WD2CN1(B) 1450(52)WD2CN1(B) 1500(54)WD2CN1(B) 220V 1400(50)WD2DN1(B) 1450(52)WD2DN1(B) 1500(54)WD2DN1(B) 14HP+18HP 2 16HP+18HP 2 18HP 3 Capacity VPhHz & k EER Capacity k COP Total capacity 50~130 of outdoor unit capacity Max. quantity 64 Type DC inverter Quantity 6 Type DC motor Quantity 6 Type R410A Factory charging (380~415V) kg(lbs.) ( ) ( ) 16 3(35 3) Factory charging (220V) kg(lbs.) ( ) ( ) 16 3(35 3) m 3 h db(a) mm mm Φ22.2(Φ78) Φ41.3(Φ1-58) Φ6(Φ14) ( ) 3 ( ) 3 380~415V kg(lbs.) ( ) ( ) 310 3(682 3) 220V kg(lbs.) ( ) ( ) 310 3(682 3) 380~415V kg(lbs.) ( ) ( ) 330 3(726 3) 220V kg(lbs.) ( ) ( ) 330 3(726 3) Operating temperature range C( F) Cooling: -5-48(23~118.4); Heating: (-4~75.2) VRF V4 Plus S Series - Heat Pump 380~415V-60Hz 220V-60Hz HP MDV- MDV- Combined type Cooling Capacity 380~415V 220V VPhHz (62)WD2CN1(B) 1730(62)WD2DN1(B) 10HP+16HP+18HP (64)WD2CN1(B) 1780(64)WD2DN1(B) 10HP+18HP & (66)WD2CN1(B) 1850(66)WD2DN1(B) 14HP+16HP+18HP k Heating EER Capacity k COP Connectable indoor unit Compressor Total capacity Max. quantity Type Quantity 50~130 of outdoor unit capacity 64 DC inverter 7 8 Fan motor Refrigerant Type Quantity Type DC motor 7 R410A 8 Factory charging (380~415V) kg(lbs.) ( ) ( ) ( ) Factory charging (220V) kg(lbs.) ( ) ( ) ( ) Pipe Liquid pipe Φ22.2(Φ78) Φ22.2(Φ78) Φ25.4(Φ1) connections Gas pipe Φ41.3(Φ1-58) Φ41.3(Φ1-58) Φ44.5(Φ1-34) Oil balance pipe Φ6(Φ14) Air flow rate Sound pressure level Net dimension (W H D) m 3 h db(a) mm ( )+( ) ( ) 4 Packing size (W H D) mm ( )+( ) 3 ( ) 4 Net weight 380~415V kg(lbs.) ( ) ( ) ( ) 220V kg(lbs.) ( ) ( ) ( ) Gross weight 380~415V kg(lbs.) ( ) ( ) ( ) 220V kg(lbs.) ( ) ( ) ( ) Operating temperature range C( F) Cooling: -5-48(23~118.4); Heating: (-4~75.2) OUTDOOR UNIT LINEUP HP MDV- MDV- Combined type Cooling Heating ~415V 1560(56)WD2CN1(B) 1630(58)WD2CN1(B) 1680(60)WD2CN1(B) 220V 1560(56)WD2DN1(B) 1630(58)WD2DN1(B) 1680(60)WD2DN1(B) 10HP 2+18HP 2 10HP+14HP+16HP+18HP 10HP+14HP+18HP 2 Capacity VPhHz & k EER Capacity k COP Total capacity 50~130 of outdoor unit capacity Max. quantity 64 Connectable indoor unit Compressor Type DC inverter Quantity Fan motor Type DC motor Quantity Refrigerant Type R410A Factory charging (380~415V) kg(lbs.) ( ) ( ) ( ) Factory charging (220V) kg(lbs.) ( ) ( ) ( ) Pipe Liquid pipe Φ22.2(Φ78) connections Gas pipe Φ41.3(Φ1-58) Oil balance pipe Φ6(Φ14) m 3 h db(a) Air flow rate Sound pressure level Net dimension (W H D) Packing size (W H D) Net weight Gross weight mm ( ) 2+ ( ) 2 mm ( ) 2+ ( ) 2 ( )+( ) 3 ( )+( ) 3 380~415V kg(lbs.) ( ) ( ) ( ) 220V kg(lbs.) ( ) ( ) ( ) 380~415V kg(lbs.) ( ) ( ) ( ) 220V kg(lbs.) ( ) ( ) ( ) Operating temperature range C( F) Cooling: -5-48(23~118.4); Heating: (-4~75.2) Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27 C(80.6 F) DB19 C(66.2 F) WB; Outdoor temperature 35 C(95 F) DB24 C(75.2 F) WB. Heating: Indoor temperature 20 C(68 F) DB15 C(59 F) WB; Outdoor temperature 7 C(44.6 F) DB6 C(42.8 F) WB. Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m(295ft.). If the total equivalent liquid length is more than 90m(295ft.), please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position of 1m(3.28ft.) in front of the unit and 1.3m(4.26ft.) above the floor. HP MDV- 380~415V 1900(68)WD2CN1(B) 1950(70)WD2CN1(B) 2000(72)WD2CN1(B) MDV- 220V 1900(68)WD2DN1(B) 1950(70)WD2DN1(B) 2000(72)WD2DN1(B) Combined type 14HP+18HP 3 16HP+18HP 3 18HP 4 VPhHz & Cooling Capacity k EER Heating Capacity k COP Connectable Total capacity 50~130 of outdoor unit capacity indoor unit Max. quantity 64 Compressor Type DC inverter Quantity 8 Fan motor Type DC motor Quantity 8 Refrigerant Type R410A Factory charging (380~415V) kg(lbs.) ( ) ( ) 16 4(35 4) Factory charging (220V) kg(lbs.) ( ) ( ) 16 4(35 4) Pipe Liquid pipe Φ25.4(Φ1) connections Gas pipe Φ44.5(Φ1-34) Oil balance pipe Φ6(Φ14) Air flow rate m 3 h Sound pressure level db(a) 68 Net dimension (W H D) mm ( ) 4 Packing size (W H D) mm ( ) 4 Net weight 380~415V kg(lbs.) ( ) ( ) 310 4(682 4) 220V kg(lbs.) ( ) ( ) 310 4(682 4) Gross weight 380~415V kg(lbs.) ( ) ( ) 330 4(726 4) 220V kg(lbs.) ( ) ( ) 330 4(726 4) Operating temperature range C( F) Cooling: -5-48(23~118.4); Heating: (-4~75.2) Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27 C(80.6 F) DB19 C(66.2 F) WB; Outdoor temperature 35 C(95 F) DB24 C(75.2 F) WB. Heating: Indoor temperature 20 C(68 F) DB15 C(59 F) WB; Outdoor temperature 7 C(44.6 F) DB6 C(42.8 F) WB. Piping length: Interconnecting piping length is 7.5m(24.6ft.), level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m(295ft.). If the total equivalent liquid length is more than 90m(295ft.), please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position of 1m(3.28ft.) in front of the unit and 1.3m(4.26ft.) above the floor

7 Indoor Unit Lineup Indoor Unit Lineup INDOOR UNITS One-way Cassette Two-way Cassette Compact Four-way Cassette Four-way Cassette Low Static Pressure Duct Medium Static Pressure Duct (A5 type) High Static Pressure Duct Wall-mounted Ceiling & Floor Fresh Air Processing Unit 37 38

8 Cassette Series One-way Cassette Thickness 153mm (6-132in.) only Indoor Unit Lineup One-way Cassette Compact design, ultra slim body with a minimum thickness of 153mm(6-132in.) for models 18-36, especially suitable for narrow ceiling, such as in lobbies and small meeting rooms. High-lift Pump Standard built-in drain pump with 750mm( in.) pump head. Thickness 153mm (6-132in.) only UItra thin 750mm ( in.) Indoor Unit Lineup Fresh Air, Improved Air Quality Reserved fresh air intake port for high quality air creates a Two-way Cassette comfortable and healthy environment (for models 45-71). Specifications Compact Four-way Cassette Four-way Cassette MDV-D18Q1VN1-DMDV-D22Q1VN1-D MDV-D28Q1VN1-DMDV-D36Q1VN1-D MDV-D45Q1VN1-DMDV-D56Q1VN1-DMDV-D71Q1VN1-D 1-phase, V,60Hz Cooling capacity Heating capacity Cooling W Heating W Airflow rate(hml) m 3 h CFM Sound pressure level(hml) db(a) Net dim.(w H D) ( ) ( ) Main body Packing dim.(w H D) ( ) ( ) Netgross weight kg(lbs.) ( ) ( ) ( ) ( ) ( ) Net dim.(w H D) ( ) ( ) Panel Packing dim.(w H D) Netgross weight Liquidgas pipe Piping connections Drain pipe Standard controller kg(lbs.) ( ) ( ) ( ) 45.4( ) Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Ф25(OD 6364) Wireless remote controller RM05BG(T)E-A Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound Level is measured 1.4m(4.59ft.) below the unit. Auto Restart Function Auto Addressing Fresh Air Auto Defrosting Easy-cleaning Panel Follow Me Anti-cold Air Function Built-in Drain Pump LED Display Built-in Filter Independent Dehumidification Timer Auto Swing Wired Controller 39 40

9 Two-way Cassette Quiet Operation High-lift Pump Four-way Cassette Various Selections Sub Duct Indoor Unit Lineup Optimized airflow duct with low resistance greatly reduces noise, down to a minimum of 24dB(A). Stylish Design and Slim Body Thanks to the stylish appearance and slim body, the unit can be harmonious with the room decoration and ambient. Slim body with only 300mm( in.) height needs small space in suspended ceilings. Installation is free of story height limitation which makes the decoration much more flexible. Standard built-in drain pump with 750mm( in.) pump head (higher pumphead can be customized). High Airflow High airflow for high ceiling application guarantees comfort in large spaces. Guarantees even airflow and temperature throughout the room. Three selections: Compact Four-way Cassette, Fourway Cassette& Four-way Cassette Silent Type. Flexible Air Distribution Type 7 discharge patterns in 2 to 4 directions can be selected to suit the requirements of the installation site or the shape of the room. Sub duct enables you to use the same air conditioner unit to cool an additional smaller space nearby. Fresh Air Intake Fresh air can enter through the cassette unit so you can enjoy even fresher air in a room. Indoor Unit Lineup 300mm( in.) 305mm(12in.) Specifications MDV-D22Q2VN1 MDV-D28Q2VN1 MDV-D36Q2VN1 MDV-D45Q2VN1 MDV-D56Q2VN1 MDV-D71Q2VN1 1-phase, V,60Hz Cooling capacity Heating capacity Airflow rate(hml) Cooling m 3 h W Heating CFM W Sound pressure level(hml) db(a) Net dim.(w H D) ( ) Main body Packing dim.(w H D) ( ) Netgross weight kg(lbs.) (7594) (80.599) Net dim.(w H D) ( ) Panel Packing dim.(w H D) ( ) Netgross weight kg(lbs.) (2333) Piping connections Liquidgas pipe Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Drain pipe Ф32(OD ) Standard controller Wireless remote controller RM05BG(T)E-A Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound Level is measured 1.4m(4.59ft.) below the unit. Compact Design, Easy Installation For Compact Four-way Cassette: Extremely compact casing suits any room's decor and requires little space for installation on a low ceiling. Due to compact body and light weight, all models can be installed without a hoist. 570mm 360 Airflow Outlet Duct connection is possible 570mm 260mm For Compact Four-way Cassette: 360 air outlet provides strong air flow circulation to cool or heat every corner of a room and evenly control temperatures. Easy Troubleshooting For Four-way Cassette& Four-way Cassette Silent Type: By adding digital tube on the display board, Error Codes can be displayed directly for troubleshooting. Lower Operating Noise For Four-way Cassette Silent Type: The newly designed fan blade, air deflector and the built-in throttling part reduce noise greatly. High-lift Drain Pump For Compact Four-way Cassette: Drain pump with a 500mm( in.) pump head is fitted as standard; maximum 600mm(23-58in.) pump head is available. For Four-way Cassette& Four-way Cassette Silent Type: Drain pump can pump condenser water up to 750mm( in.) high, which simplifies installation of the drain piping system

10 Compact Four-way Cassette Four-way Cassette Silent Type Indoor Unit Lineup Cooling capacity Heating capacity Airflow rate(hml) Sound pressure level(hml) Main body Panel Piping connections Standard controller MDV-D22Q4VN1-A3 MDV-D28Q4VN1-A3 MDV-D36Q4VN1-A3 MDV-D45Q4VN1-A3 1-phase, V,60Hz Cooling W Heating W Net dim.(w H D) Packing dim.(w H D) Netgross weight Net dim.(w H D) Packing dim.(w H D) Netgross weight Liquidgas pipe Drain pipe m 3 h CFM db(a) kg(lbs.) kg(lbs.) ( ) ( ) 1620( ) 1822( ) ( ) ( ) 35(6.611) Ф6.35Ф12.7(Ф14Ф12) Ф25(OD 6364) Wireless remote controller RM05BG(T)E-A Cooling capacity Heating capacity Airflow rate(hml) Sound pressure level(hml) Main body Panel Piping connections Standard controller MDV-D28Q4VN1-E MDV-D36Q4VN1-E MDV-D45Q4VN1-E MDV-D56Q4VN1-E MDV-D71Q4VN1-E 1-phase, V,60Hz Cooling W Heating W Net dim.(w H D) Packing dim.(w H D) Netgross weight Net dim.(w H D) Packing dim.(w H D) Netgross weight Liquidgas pipe Drain pipe m 3 h CFM db(a) ( ) ( ) kg(lbs.) ( ) ( ) ( ) ( ) kg(lbs.) 69( ) Φ6.35Φ12.7(Φ14Φ12) Ф9.53Ф15.9(Ф38Ф58) Ф32(OD ) Wireless remote controller RM05BG(T)E-A Indoor Unit Lineup Four-way Cassette MDV-D28Q4N1-D MDV-D36Q4N1-D MDV-D45Q4N1-D MDV-D56Q4N1-D MDV-D71Q4N1-D 1-phase, V, 60Hz Cooling capacity Heating capacity Airflow rate(hml) Cooling m 3 h W Heating CFM W Sound pressure level(hml) db(a) Main body Net dim.(w H D) Packing dim.(w H D) ( ) ( ) Netgross weight Net dim.(w H D) kg(lbs.) 2428( ) 2630( ) ( ) Panel Packing dim.(w H D) ( ) Piping connections Netgross weight Liquidgas pipe kg(lbs.) 58( ) Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Drain pipe Ф32(OD ) Standard controller Wireless remote controller RM05BG(T)E-A MDV-D80Q4N1-D MDV-D90Q4N1-D MDV-D100Q4N1-D MDV-D112Q4N1-D MDV-D140Q4N1-D 1-phase, V, 60Hz Cooling capacity Heating capacity Airflow rate(hml) Cooling m 3 h W Heating CFM W Sound pressure level(hml) db(a) Net dim.(w H D) ( ) Main body Packing dim.(w H D) ( ) Netgross weight kg(lbs.) 2630(57.366) Panel Net dim.(w H D) Packing dim.(w H D) Netgross weight kg(lbs.) Piping connections Liquidgas pipe Drain pipe Standard controller ( ) ( ) 3237( ) ( ) ( ) 58( ) Ф9.53Ф15.9(Ф38Ф58) Ф32(OD ) Wireless remote controller RM05BG(T)E-A Cooling capacity Heating capacity Airflow rate(hml) Sound pressure level(hml) MDV-D80Q4VN1-E MDV-D90Q4VN1-E MDV-D100Q4VN1-E MDV-D112Q4VN1-E MDV-D140Q4VN1-E 1-phase, V,60Hz Cooling W Heating W m 3 h CFM db(a) Net dim.(w H D) ( ) ( ) Main body Packing dim.(w H D) ( ) ( ) Netgross weight kg(lbs.) ( ) (63.175) (6879.9) Net dim.(w H D) ( ) Panel Packing dim.(w H D) Netgross weight kg(lbs.) ( ) 69( ) Piping connections Liquidgas pipe Ф9.53Ф15.9(Ф38Ф58) Drain pipe Ф32(OD ) Standard controller Wireless remote controller RM05BG(T)E-A Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound Level is measured 1.4m(4.59ft.) below the unit

11 Indoor Unit Lineup Indoor Unit Lineup Duct series nit h Fres gu n i s es oc Pr Air uct h Hig ssu re mp iu Med e) yp A5 t t( uc re d es Pr atic St D sure ct du sure res Low 45 ic p stat 46

12 Indoor Unit Lineup Low Static Pressure Duct Low Sound Level Utilizes the centrifugal type blower, provides a minimum noise level of 24dB (A), an excellent choice for hotels and other sound-sensitive locations. V Shape Evaporator V shape evaporator design enhances heat exchanging efficiency by around 22. Easy Installation and Maintenance The EXV is fixed inside the indoor unit. Auto Restart Function Auto Addressing Independent Auto Defrosting Dehumidification Specifications Cooling capacity Follow Me Anti-cold Air Function Timer Wired Controller Compact Design Uniformed height of 210mm(8-1764in.), compact design for easy locate where ceiling space is limited. Entire body adopts fireproof plastic material the minimum weight is 14kg(30.9lbs). Options 210mm(8-1764in.) Min.5mm Ceiling Drain pump with a 750mm( in.) pumphead is an optional accessory. 750mm( in.) Ceiling MDV-D18T3VN1-C MDV-D22T3VN1-C MDV-D28T3VN1-C MDV-D36T3VN1-C MDV-D45T3VN1-C MDV-D56T3VN1-C MDV-D71T3VN1-C 1-phase, V,60Hz Cooling W Heating W m 3 h CFM Pa db(a) Medium Static Pressure Duct (A5 type) Compact Size Only 210mm(8-932in.) (models 22~71) or 270mm(10-58in.) (models 80 to 112) or 300mm( in.) (model 140) in height. Flexible Control and Easy Maintenance The electrical control box can be removed 1m away from the unit for easy maintenance access. Customers need to request this service in advance for it is done at TGM CAC factory. Standard functional ports are included such as Remote OnOff Dry contact switch and Alarm signal output (220V). Auto Restart Function Auto Addressing Fresh Air Specifications Cooling capacity Heating capacity Airflow rate(hml) 8-932in. or 10-58in. or in. Auto Defrosting Built-in Filter Min.5mm Ceiling Follow Me Anti-cold Air Function Built-in Drain Pump Timer Independent Dehumidification Convenient Installation EXV is fixed inside the indoor unit. Standard filter is housed in an aluminum frame. A rear air inlet is standard and an inlet at the bottom is optional. Both use the same connectable duct. Air intake from back High-lift Drain Pump Drain pump with a 750mm pump head is fitted as standard. Wired Controller Super High Air Flow Air intake from bottom MDV-D22T2VN1-DA5 MDV-D28T2VN1-DA5 MDV-D36T2VN1-DA5 MDV-D45T2VN1-DA5 MDV-D56T2VN1-DA5 1-phase, V,60Hz Cooling W Heating W m 3 h CFM External static pressure(minstdmax) Pa Sound pressure level(hml) db(a) Net dimension(w H D) Packing dimension(w H D) Netgross weight kg(lbs.) ( ) ( ) ( ) ( ) ( ) ( ) Piping connections Liquidgas pipe Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Drain piping Ф25(OD 6364) Standard controller Wired controller KJR-29B1BK-E (6 meters connection wire) Heating capacity MDV-D71T2VN1-DA5 MDV-D80T2VN1-BA5 MDV-D90T2VN1-BA5 MDV-D112T2VN1-BA5 MDV-D140T2VN1-BA5 1-phase, V,60Hz Cooling capacity Airflow rate(hml) Heating capacity External static pressure(minstdmax) Cooling W Heating W Sound pressure level(hml) Airflow rate(hml) m 3 h ( (46 CFM Net dimension(w H D) ( ) 18-12) ) External static pressure(minstdmax) Pa Sound pressure level(hml) db(a) ( ( Packing dimension(w H D) ( ) ) ) ( Net dimension(w H D) ) ( ) ) Netgross weight kg(lbs.) ( ) ( ) ( ) ( ( Packing dimension(w H D) ) ( ) ) Liquidgas pipe Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Netgross weight kg(lbs.) ( ) ( ) 4048( ) 4958( ) Piping connections Drain piping Ф25(OD 6364) Liquidgas pipe Ф9.53Ф15.9(Ф38Ф58) Piping connections Drain piping Ф25(OD 6364) Standard controller Wireless remote controller RM05BG(T)E-A Standard controller Wired controller KJR-29B1BK-E (6 meters connection wire) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound Level is measured 1.4m(4.59ft.) below the unit. * External static pressure is based on high speed indoor air flow. Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound Level is measured 1.4m(4.59ft.) below the unit. * External static pressure is based on high speed indoor air flow Indoor Unit Lineup

13 High Static Pressure Duct Specification Indoor Unit Lineup Flexible Duct Design External static pressure can be up to 196Pa (models 71 to 160) or 280Pa (models 200 to 560). The maximum length for air supply is about 14m(45.9ft) at a height of 6.5m(21.3ft). With a 420mm( in.) (models 71 to 160) thick body, the minimum distance required above the ceiling is 450mm ( in.). The maximum air-supply length is 14m Fresh air in take 420mm Min. 450mm Cooling capacity Heating capacity Airflow rate(hml) External static pressure(minstdmax) Sound pressure level(hml) Net dimension(w H D) Packing dimension(w H D) MDV-D71T1VN1-B MDV-D80T1VN1-B MDV-D901T1VN1-B MDV-D112T1VN1-B MDV-D140T1VN1-B MDV-D160T1VN1-B 1-phase, V,60Hz Cooling W Heating W m 3 h CFM Pa db(a) ( ) ( ) ( ) ( ) Indoor Unit Lineup Air supply INDOOR UNIT The height of air supply is 6.5m Air return INDOOR UNIT Netgross weight Piping connections Standard controller Liquidgas pipe Drain piping kg(lbs.) ( ) ( ) 6870( ) ( ) Ф9.53Ф15.9(Ф38Ф58) Ф25(OD 6364) Wired controller KJR-29B1BK-E (6 meters connection wire) Double-skin Drainage Pan Double-skin drainage pan provides double protection for ceilings (models 71 to 160 and models 400 to 560) Option Drain pump with 750mm( in.) pump head is optional (models 71 to 160). 750mm Ceiling Cooling capacity Heating capacity Airflow rate(hml) External static pressure(minstdmax) Sound pressure level(hml) Net dimension(w H D) MDV-D200T1N1-B MDV-D250T1N1-B MDV-D280T1N1-B MDV-D400T1N1 MDV-D450T1N1 1-phase, V,60Hz Cooling W Heating W m 3 h CFM Pa db(a) ( ) ( ) Convenient Installation The EXV is fixed inside the indoor unit (models ), requires no extra connection. Standard filter is housed in an aluminum frame, which is removable from the bottom in a downward direction. Flange for air inletoutlet duct connection is standard. Flexible Control and Convenient for Maintenance Wired remote controller KJR-29B1BK-E comes standard, and wireless remote controller RM05BG(T)E-A comes as an option. The display board is connected to the E-box in factory, easier troubleshooting with LED display. Easy access filters both at the rear & bottom. Standard functional port such as remote onoff dry contact. Packing dimension(w H D) Netgross weight kg(lbs.) Liquidgas pipe Piping connections Drain piping Standard controller ( ) ( ) (115129) (235250) Ф9.53Ф15.9 2(Ф38Ф58) 2 Ф9.53Ф22.2 2(Ф38Ф78) 2 Ф32(OD ) Wired controller KJR-29B1BK-E (6 meters connection wire) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound Level is measured 1.4m(4.59ft.) below the unit. * External static pressure is based on high speed indoor air flow. Auto Restart Function Auto Addressing Independent Auto Defrosting Dehumidification Built-in Filter Follow Me Anti-cold Air Function Wired Controller Timer Built-in Drain Pump 49 50

14 Wall-mounted Specification Indoor Unit Lineup S type panel Auto Restart Auto Addressing Function Timer C type panel Auto Defrosting Easy-cleaning Follow Me Anti-cold Air Panel Function Auto Swing LED Display R type panel Built-in Filter Independent Wired Dehumidification Controller MDV-D71G-R3QN1Y MDV-D80G-R3QN1Y MDV-D90G-R3QN1Y 1-phase, V, 60Hz Cooling capacity Heating capacity Cooling W Heating W Airflow rate(hml) m 3 h CFM Sound pressure level(hml) db(a) Net dimension(w H D) Packing dimension(w H D) Netgross weight kg(lbs.) ( ) ( ) ( ) Piping connections Liquidgas pipe Ф9.53Ф15.9(Ф38Ф58) Drain piping Ф16.5(OD 2132) Standard controller Wireless remote controller RM05BG(T)E-A Indoor Unit Lineup Convenient Installation Auto Swing Louver Multi-directional refrigerant outlet pipe: left\right\rear, more The Auto Swing Louver function ensures that the air flexible for installation. direction corresponds to the mode selected. EXV is built-in the indoor unit, compact size, lengthened the connection pipe; gas pipe: 468mm( in.); liquid pipe: 550mm( in.), more flexible for installation. Adopts new type fixing plate, stable and easy to install. The mechanical expansion valve offers 2,000-stage element positioning to ensure precise flow control and less modulation noise when the EXV is operating for a quiet and comfortable environment. Three air flow speeds: low, medium and high; double air guides. Smoother airflow and less turbulence is ensured by the multi-blade fan and the air guide design. 1 2 Step 3 Swing 4 Rear Left Right Optimal Comfort Through Better Flow Control and Quiet Operations MDV-D22GN1-S MDV-D28GN1-S MDV-D36GN1-S MDV-D45GN1-S MDV-D56GN1-S 1-phase, V, 60Hz Cooling capacity Heating capacity Cooling W Heating W Airflow rate(hml) m 3 h CFM Sound pressure level(hml) db(a) Net dimension(w H D) ( ) ( ) Packing dimension(w H D) ( ) ( ) Netgross weight kg(lbs.) ( ) (33.443) Piping connections Liquidgas pipe Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Drain piping Ф16.5(OD 2132) Standard controller Wireless remote controller RM05BG(T)E-A MDV-D22GN1YB MDV-D28GN1YB MDV-D36GN1YB MDV-D45GN1YB MDV-D56GN1YB 1-phase, V, 60Hz Cooling capacity Heating capacity Cooling W Heating W Airflow rate(hml) m 3 h CFM Sound pressure level(hml) db(a) Net dimension(w H D) ( ) ( ) Packing dimension(w H D) ( ) ( ) Netgross weight kg(lbs.) ( ) 1519( ) Piping connections Liquidgas pipe Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Drain piping Ф16.5(OD 2132) Standard controller Wireless remote controller RM05BG(T)E-A Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound level is measured 1m(3.28ft.) below the air out-let both horizontally and vertically

15 Indoor Unit Lineup Ceiling & Floor Specification MDV-D36DLN1-C MDV-D45DLN1-C MDV-D56DLN1-C MDV-D71DLN1-C Cooling capacity Heating capacity 1-phase, V, 60Hz Cooling W Heating W Airflow rate(hml) m 3 h CFM Sound pressure level(hml) db(a) Net dimension(w H D) Packing dimension(w H D) ( ) ( ) Netgross weight kg(lbs.) 2632( ) 2834( ) 2834( ) 2834( ) Piping connections Liquidgas pipe Ф6.35Ф12.7(Ф14Ф12) Ф9.53Ф15.9(Ф38Ф58) Drain piping Ф16(OD 58) Standard controller Wireless remote controller RM05BG(T)E-A Indoor Unit Lineup Convenient Installation Auto Restart Auto Addressing Timer Auto Defrosting Easy-cleaning Follow Me Anti-cold Air Auto Swing LED Display Built-in Filter Independent Wired Function Panel Function Dehumidification Controller The slim and sleek structure design ensures easy installation. It can be installed into a corner of the ceiling even if the ceiling is very narrow. >20 Drop ceiling 203mm The unit can be installed either horizontally on the ceiling or Air Outlet vertically against the wall. Auto Swing and Wide Angle Air Flow Two direction auto swing - vertical and horizontal. The range of horizontal air discharge is widened which secures wider air flow distribution to provide more comfortable air circulation no matter where the unit is set up. Three air flow speeds: low, medium and high; double air guides. MDV-D80DLN1-C MDV-D90DLN1-C MDV-D112DLN1-C MDV-D140DLN1-C MDV-D160DLN1-C 1-phase, V, 60Hz Cooling capacity Heating capacity Airflow rate(hml) Cooling m 3 h W 1, , ,9801,8601, ,9801,8601, ,3002,1001, Heating CFM W ,1651,0951, ,1651,0951, ,3541,2361, Sound pressure level(hml) db(a) Net dimension(w H D) ( ) ( ) ( ) Packing dimension(w H D) Netgross weight Piping connections Standard controller Liquidgas pipe Drain piping ( ) ( ) ( ) kg(lbs.) ( ) 5459( ) ( ) Ф9.53Ф15.9(Ф38Ф58) Ф16(OD 58) Wireless remote controller RM05BG(T)E-A Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Floor standing : Sound level is measured 1m(3.28ft.) horizontally and 1m(3.28ft.) vertically from the air-outlet. Ceiling mounted: Sound level is measured 1m(3.28ft.) horizontally and 1m(3.28ft.) vertically from the air-outlet. More Comfortable Auto Swing & Wide-angle Airflow Adopts electrical expansion valve, ensuring precise flow control, lower modulation noise when EXV is operating. Low noise operations; minimum 36 db(a). Smoother airflow and less turbulence due to the multi-blade fan and the air guide design

16 Fresh Air Processing Unit Specification Indoor Unit Lineup MDV-D125T1VN1-FA MDV-D140T1VN1-FA MDV-D200T1VN1-FA MDV-D250T1VN1-FA MDV-D280T1VN1-FA 1-phase, V,60Hz Cooling capacity Heating capacity Cooling W Heating W Airflow rate(hml) m 3 h CFM External static pressure(minstdmax) Pa Sound pressure level(hml) db(a) Net dimension(w H D) ( ) ( ) Indoor Unit Lineup 100 Fresh Air Processing Unit High External Static Pressure Packing dimension(w H D) Netgross weight Piping connections Standard controller Liquidgas pipe Drain piping kg(lbs.) ( ) ( ) Ф9.53Ф15.9(Ф38Ф58) ( ) (251274) Ф25(OD 6364) Ф32(OD ) Wired controller KJR-29B1BK-E (6 meters connection wire) Both fresh air filtration and heatingcooling can be achieved in a single system. Indoor units and fresh air processing unit can be connected to the same refrigerant system, increasing design flexibility and greatly reducing total system costs. The maximum airsupply length is 14m Fresh air in take Air supply Indoor unit The height of air supply is 6.5m Air return External static pressure can be up to 196Pa(models 125 to 140) and 280Pa(models 200 to 280) for more flexible duct applications. The maximum length of air supply is around 14m(45.9ft) and the maximum height of air supply is about 6.5m(21.3ft). Healthy and Comfortable Fresh air is imported, providing a healthy and comfortable living environment. Four speed fan motor(model 125&140). Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27 C(80.6 F)DB, 19 C(66.2 F)WB, outdoor temp.: 35 C(95 F)DB, equivalent ref. piping: m(26.25ft.) (horizontal). 2. Nominal heating capacities are based on the following conditions: return air temp.: 20 C(68 F)DB, outdoor temp.: 7 C (44.6 F)DB, 6 C(42.8 F)WB, equivalent ref. piping: 8m(26.25ft.) (horizontal). 3. Sound Level is measured 1.4m(4.59ft.) below the unit. * External static pressure is based on high speed indoor air flow. Connection Conditions: The following restrictions must be observed in order to maintain the indoor units connection to the same system. * When outdoor-air processing units are connected, the total connection capacity must be within 50 to 100 of that of the outdoor units. * When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30 that of the outdoor units. * Outdoor-air processing units can be used without indoor units. * The fresh air processing unit is not available for V4+R system & 8~26 side discharge outdoor units. Innovative air supply technology for excellent room temperature control Outdoor Units Layout Example: Indoor Unit Indoor Unit Outdoor Air processing unit Air-conditioning Fresh air supply 55 56

17 Control Systems Wireless Remote Controller RM02 RM05 Wired Controller KJR-29B KJR-90C KJR-86C KJR-10B KJR-12B KJR-120B KJR-120C KJR-27B Centralized Controller & Monitor CCM30 MD-CCM03 MD-CCM09 KJR-90B MD-CCM02 Network Control Software & Gateways IMM Software & M-Interface Data Converter CCM15 KNX Gateway MD-KNX BACnet Gateway CCM08 LonWorks Gateway LonGW64 Modbus Gateway CCM-18A Accessories Hotel Key Card Interface Module MD-NIM05 Infrared Sensor Controller MD-NIM09 3-Phase Protector Digital Power Ammeter Indoor Unit Group Controller-KJR-150A Remote Alarm Controller KJR-32B Network Electricity Distribution Module MD-NIM10 AHU Control Box TGM Outdoor Unit Diagnosis 57 58

18 Wireless Remote Controller RM02 RM05 Benefits name RM02 RM05 Auto mode Dry mode Heat mode Cool mode Fan mode 24h Timer Lock Address setting Follow Me 24 Mode change Temp. setting Fan speed control Auto Mode Auto mode is specially designed for V4+R system. Can automatically switch between cooling and heating mode based on the temperature difference between the indoor temperature and set temperature. * Runs cooling mode only for the 2-pipe system. Background Light The background light allows users to operate the device in a dark room. The device lights up when a button is pressed, and turns off when a given operation is completed. Address Setting In addition to the machine's auto addressing function, users can set the indoor unit's address on the wireless remote controller RM05RM02. Follow Me With the follow me function, the temperature sensor built-in to the remote controller automatically adjusts temperature and sends it to the indoor unit, making the room more comfortable. *The Follow Me function is available in RM02. Keyboard lock Eco operation Swing function Air direction 24h timer Clock display Address setting Follow me function 26 C shortcut setting Background light Notes: 1. The ECO function needs to match with the corresponding indoor units. 2. : available : unavailable Specifications RM02 Dimensions (H W D)(mm) Power (V) RM V(LR03AAA)

19 Wired Controller KJR-86C KJR-29B KJR-90C Remote Signal Receiving Function KJR-29B and KJR-90C provide a signal receiver for the remote controller. Signals from the remote control can be received by a wired controller, then sent to the indoor unit for easy control. Remote signal receiver Clean filter reminder icon KJR-29B (Touch key) Silent Key Address Setting Auto mode 24 Dry mode Heat mode Cool mode Fan mode 24h Timer Lock Clean filter Address setting Follow Me reminder Silent mode KJR-29 and KJR-90C have an address setting function. Service personnel can set the address for the indoor unit for easy installation and future maintenance. Clean Filter Reminder The wired controller records the total running time of the indoor unit. When the accumulated running time reaches the pre-set value, the system will remind users to clean the indoor unit's filter. Cleaning the filter regularly keep indoor air fresh, clean and good for your health. Silent Mode In cooling, heating and auto mode, operating silent mode can lower running noise by setting the fan speed to low for a quieter environment. Keyboard Locking The locking function can be used to prevent other people from using the controller. Follow Me The temperature sensor built-in to the wired controller senses the surrounding temperature and adjusts the room temperature for perfect comfort. *The Follow Me function is available in KJR-29B and KJR-90C. One-key 26 C KJR-86C has a one-key 26 C function. For saving energy and remaining comfortable, 26 C is the ideal temperature

20 User Friendly Design KJR-86C is a hidden mode controller specially designed for hotels, hospitals, schools and other similar types of buildings. Hidden mode key controller: Press the temperature buttons " " and " " simultaneously for 3 seconds to select the operation mode: COOL or HEAT. KJR-10B KJR-12B KJR-86C Combination key 26 C Shortcut setting Selecting mode Built-in Timer Auto mode Dry mode Heat mode Cool mode Fan mode 24h Timer Lock Clean filter Address setting Follow Me reminder The built-in daily timer offers automatically starts and stops the system at set times based on user needs. ON 24 C OFF 24 User Friendly Installation The background light function makes it easy to use in the dark. As small as an electric switch, the installation effect more attractive. 86mm 86mm 86mm Follow Me The indoor unit is set to work in automode from 8:00 to 20:00 The FOLLOW ME function enables the wired controller to detect the air temperature at the user's height instead of the ceiling or floor for accurate temperature configuration. *The Follow Me function is available in KJR-12B. Sensor part Time 86mm FOLLOW ME Button KJR-80C KJR-90C Addresses Setting Easy Connection Auto Restart Function The address setting function is coupled with easy installation and simple future maintenance. Service personnel can set the address for the indoor unit using KJR-10B, KJR-29B and KJR-90C. The wired controller conveniently connects to the indoor unit's display panel via connecting wire. If the power fails, the system records running parameters such as: ONOFF state, mode, Fan speed, Temperature, Swing and Locking status. When powered on again, the system automatically checks the status before the failure. Display panel Wired controller Wired controller Indoor main board 63 64

21 V4 Plus R Wired Controller Weekly Schedule Timer Wired Controller KJR-120B KJR-120C Auto Mode Simple Design Auto mode is specially designed for the V4 plus R series Weekly schedule wired controller can query the indoor temperature and the set parameters of the weekly schedule. It can show In auto mode, the V4 plus R system can automatically switch between COOL or HEAT mode according to the temperature the error codes and running state of the indoor unit. The LCD backlight enables users to operate the device in the dark. difference between Tf (indoor temperature) and Ts (setting temperature). * KJR-120B is compatible with the 2-pipe system. In auto mode, it only can run in cooling mode. Weekly Schedule Timer Error Display The weekly schedule timer function allows users to set up to four scheduled periods per day for frequent adjustments. If a malfunction occurs, the temperature setting display area will show the error code. The error status can be checked easily on the indoor unit's wired controller. The Schedule feature allows you to program device behavior. If a device must follow a certain schedule, you can program the device to operate only at the scheduled times. Scheduled devices do not activate unless programmed to do so. They are centrally managed, significantly reducing energy consumption. Filter Cleaning Reminder Delay Function The wired controller records the total running time of the indoor unit. When the accumulated running time reaches the pre-set value, it will remind you This function is specifically designed for people who work overtime. Pressing the Delay button postpones system shutdown by 1 or 2 hours. to clean the air filter. Cleaning the filter regularly keeps the indoor air fresh and clean, and is good for your health. Error Display If a malfunction occurs, the temperature setting display area will show the error code. The error status can be checked easily on the indoor unit's wired controller. Silent Mode In cooling, heating, and auto mode, silent mode reduces the running noise by setting the fan speed to low so you can enjoy peace and quiet while F C Switch remaining comfortable. Press the left-right and up-down buttons simultaneously for three seconds to switch between F and C. C F F C switch 65 66

22 HRV Wired Controller Benefits KJR-27B name KJR-10B KJR-12B KJR-29B KJR-90C KJR-86C KJR-120B KJR-120C Fan speed control KJR-27B is individually designed for HRV Heat Recovery Ventilator. The HRV can work in the following modes: exhaust, air supply, bypass, heat exchange, and auto. Mode change Auto mode for V4+R Eco mode Keyboard lock Swing function Built-in Timer Background-light Built-in daily timer offers the convenience of automatically starting and stopping the HRV at the times set Setup screen example Set to Wednesday: 8:00 to 20:00 24h timer Clock display Address setting ON 24 C OFF Receiving remote signal Specifications Time Clean filter reminder Follow me function Silent mode KJR-29B KJR-90C KJR-86C KJR-10B KJR-12B KJR-27B KJR-120B KJR-120C 26 C shortcut setting Dimensions (H W D)(mm) Display indoor temp. Power (V) DC 5V (Supplied by indoor unit) DC 12V by IDU F C initial setting Weekly schedule timer Delay function Auto restart Error code display Notes: 1. ECO function needs to match with the corresponding indoor units. 2. : available : unavailable Power (V) 67 68

23 Centralized Controller & Monitor Indoor Centralized Controller CCM30 MD-CCM03 MD-CCM09 Three Lock Modes The centralized controller is a better way to manage indoor units. Users can choose to lock the wireless controller, running mode, or the centralized controller's keyboard. Wiring Example Locking Running Mode Locking Remote Controller Locking Keyboard The device connects to the master outdoor units of Midea's newly designed products to simplify and centralize the wiring configuration. The two connection methods are as follows: X,Y,E P,Q,E P,Q,E P,Q,E 24 Weekly Swing Heat mode Cool mode Fan mode 24h Timer Keyboard lock Remote Cooling lock Heating lock Dry mode Weekly Clean filter controller lock schedule reminder Network access Centralized Control The centralized controller is a multifunctional device that can control up to 64 indoor units within a maximum connection length of 1,200m. User can group control or individual control and the set temperture of each unit can also different. X,Y,E X,Y,E X,Y,E X,Y,E *1. If it connects to XYE ports of master ODU, the ODU must be set to auto addressing mode. 2. Some products can only be connected with MD-CCM09 from indoor side XYE ports. 21 C OFF 26 C 27 C OFF 17 C Application Example Ensure the address is not repeated. Units can be from different systems, with up to 64 indoor units. This greatly reduces system limitations. *1. For the 2-pipe system, the running mode should be in the same mode. 2. For 3-pipe system, the running mode can be set as required. 20 C System 1 System System 2 System 3 Max.64 indoor units System 4 System N 69 70

24 Air Filter Cleaning Reminding Function CCM30 is a new design and touch key controller. The reminder to clear the filter is only available on the touch-key central controller CCM30. The "FL" icon indicates that the air filter in a given indoor unit needs cleaning. Clean filter reminder CCM30(Touch key) Weekly Schedule for MD-CCM09 MD-CCM09 is a weekly centralized controller. It can control 64 indoor units in a weekly schedule. Users can set up to four periods per day, and select the desired running mode and room temperature. The operating object can be a single indoor unit or all the indoor units. Sun Mon Tue Wed Thu Fri Sat 28 C 26 C 26 C 26 C 26 C 26 C 28 C 8:00 16:00 23:59 22 C 24 C 22 C 17 C 23 C 22 C 17 C 23 C 22 C 17 C 23 C 22 C 26 C 22 C 26 C off 24 C Easy Installation The centralized controller offers two installation modes. Unlike the B structure, the A structure must be embedded into SingleUnified Control Mode The control object can either be a single unit or all units, which vastly simplifies the control process. Operation signal feedback ensures that all units are working in the correct mode. OPR.UNSUCCESS the wall. Both are easy to operate. Upper side outlet Indoor Unit Working Status Display Displays indoor units' working status and error codes, so users can easily identify faults by checking the error code A B Under side outlet Rear side outlet table in the user's manual before contacting a service engineer. Error code or protection code Connecting status matrix *A and B structure is available for CCM30 B structure lead-out mode sketch Stylish Design CCM's stylish design suits high-end environments. The keyboard lock function is used to prevent operating mistakes. Access to Network Monitoring The centralized controller can connect up to 64 indoor units on the network monitoring and building management systems. MAX.64 X,Y,E F1,F2,E Indoor CCM *If it connects to XYE ports of master ODU, the ODU must be set to auto addressing mode. Network access is only available for CCM03 and CCM

25 Benefits Unified OnOff Controller Stylish unified controller design with a clear panel. Can control single or group indoor units. CCM30 MD-CCM03 MD-CCM09 Max. number of indoor units Group control Individual control Fan speed control Unified Control KJR-90B offers onoff and heatingcooling functions for indoor units based on preset temperatures to ensure easy management. KJR-90B Mode selection Centralized Control Mode lock KJR-90B can be used to centrally control up to 16 indoor units. Remote controller lock Max.16 Keyboard lock Weekly schedule timer 24h timer Error check Emergency start Light Indicator The LEDs on KJR-90B indicate indoor units' running status for easy fault detection. The lights switch off automatically to save energy once an action is completed. The indicators are as follows: Emergency stop Light Blue Red Flash Background light Single OnOff key Unified OnOff key CoolingFan Heating IDU Error EEPROM Error Swing function Air filter cleaning reminder Easy Installation KJR-90B can be easily mounted on the built-in cabinet: Parameter query BMS access Notes: : available : unavailable Specifications Specifications MD-CCM03 CCM30 MD-CCM09 KJR-90B Dimensions (H*W*D)(mm) and Dimensions (H*W*D)(mm) Power (V) V(5060Hz) Power (V) DC 5V(Supplied by indoor unit) 73 74

26 Outdoor Centralized Monitor Network Control Software & Gateways MD-CCM02 Query parameters Power consumption Protection Error codes Forced Cooling Communication by ODU Communication by PC Forced Cooling ODU Parameters Display MD-CCM02 enables users to easily check outdoor units' running status, including frequency, temperature, current, pressure, protection codes and error codes. Access to Network Monitoring Graph 2 LCD Screen MD-CCM02 can connect up to 8 refrigerant systems and 32 outdoor units to the network system. IMM Software K1,K2,E Max.4 PC SMS modem system 1 Web Access Max.32 K1,K2,E Max.4 Laptop Router Pad system 2 IMM Gateway M-interface web gateway K1,K2,E Max.4 system 8 AC Systems Power ammeter Specifications Outdoor units Indoor units Dimensions(H W D)(mm) Power (V) MD-CCM V(5060Hz) 75 76

27 Network Control Software & Gateways IMM(Intelligent Manager of TGM) 4th Generation Network Control System Network Control Application WEB ACCESS LOCAL IMM software M-interface Gateway Intelligent Manager of TGM is designed specifically to control VRF systems. Based on a centralized format, it controls and monitors all the system s functions. It can be used as a flexible multi-purpose system and applied to meet various requirements according to the scale, purpose, and control method of each building. Key Features Firewall Up to 4 M-interface gateways, 64 refrigerant systems, 1,024 indoor units, and 256 outdoor units can be controlled by one PC. User friendly operation Web access for M-interface gateway Central building monitoring and control Energy saving management Zone management Warning message *SMS modem(optional) Electricity charge distribution Annual schedule management Low-load operation indicator Generate operational history reports (daily, weekly) Fault display & Warning message Clean filter reminder Emergency stop and Alarm signal output Multiple languages Backup 9 MAX:1024 Web Access function Energy Saving Management Schedule management Visual Navigation Warning Message Data Backup Multiple Languages Electricity Charge Distribution Can run on Window 7_3264 bit, Window XP_32 bit and Window 8. Can monitor and control AC anytime, anywhere by PC, iphone, ipad and notebook computer. Support WEB access: IE, Firefox, Safari and Chrome. Enables remote access through DSL, VPNs and so on

28 Simple Operation & Management Click & Operate, a user-friendly interface allows non-experts to easily run the building management system. IMM offers a massive, flexible, and highly efficient centralized management program. Login interface Main interface Web Access Function With the web access function, a PC, laptop or a smart phone can be used as a remote controller. The function supports up to four users online at the same time. Connects with LAN and WAN so you can monitor and manage the AC device remotely. *WAN access needs to set up the VPN. Visual Navigation Allows the floor plan to be imported. Dragging the AC device to anywhere can locate the AC quickly, and you can view it to specify the physical location of the AC. With the visual navigation function, the layout of AC is showed on the floor plan directly and the running solution is clear. Office Meeting room Living room Schedule Management Automatically performs facility startstop control, switches the operating mode, sets temperatures and enablesdisables the remote control according to the present time schedule. Guest room Users can set up dayweek task for running periodically. Users can choose indoor units and assign task times as required. Except for the conventional setup, the system offers all kinds of energy conservation options

29 Electricity Charge Distribution (Patented) Automatic & Manual Topology Provides information on proportional electrical power distribution to optimize electricity consumption management. With automatic topology mode and manual topology mode. Uses software to calculate electric power proportional distribution. The software also outputs and saves electricity consumption data for each indoor unit (or group) connected to the intelligent manager. Applies the patented TGM Calculation Method to calculate consumption rates according to the capacity demand Can topologize automatically between the indoor and outdoor units in the refrigerant system. based on various parameters: temperature setting, room temperature, running mode, rated HP, public areas, unused rooms, and nighttime use. It outputs this information on a charge calculation sheet to evenly divide power consumption charges among tenants. Automatic topology One M-interface gateway can support, up to 4 refrigerant systems, 256 indoor units and 16 outdoor units. Electricity charges can be easily divided when billing users for air conditioning power charges; for example, for Manually set the topologize method between the indoor tenants in a commercial building, offices in a rented building or rooms in a hotel. User A User B User C Power According to the actual power division for each user Warning Message and outdoor units in the refrigerant system. One M-interface gateway can support, up to 16 refrigerant systems, 256 indoor units and 64 outdoor units. Manual topology The system can receive error messages from air conditioning units in more than one building on public phone lines. If a User A User B User C particular factor influences normal operations, the system will send a message to technicians as an early warning. *Requires the TGM "SMS Modem" to send automatic warning messages to designated phone numbers. Energy consumption can be divided according to the running time, set temp, return air temp, and refrigerant flow. Energy Saving Management Based on a predetermined schedule, the Intelligent Manager executes capacity control and intermittent operations on all air conditioning units to maintain a high comfort index. User can set a limit on any running unit, any parameter, such as cooling temp., heating temp., fan speed, Data Management Monitors the operating information of individual indoor units to distribute the power consumption of outdoor units. Stores operation data on multiple systems and reports it in excel format for visual management. Uses IMM software to generate tenant reports and help building owners bill for energy use. operation mode, and so on. * 1. Meet with the <Public building energy efficiency management regulations>. Zone Management 2. Matches the corresponding indoor units. Easy to control and manage air conditioners. Easy to manage the energy charges of public devices. Data Backup Double data backup stored on the M-interface and IMM database. The M-interface gateway automatically backs up power data for 1 or 2 months if a system failure occurs. Examples: if there is a PC power failure or a system crash, the M-interface will automatically backup the data to the gateway. IMM software also stores running data on the software database. Colorful Language Obtained Supports multiple languages. Customers can select their required language. 9 different languages: English French Italian Russian German Spanish Simple Chinese Polish Korean 81 82

30 Data Converter The cloud server controller enables remote control on the VRF system through the Internet. Smart phones, tablets, laptops, and desktop PCs can serve as a web controller for up to 64 indoor units. Weekly Schedule Control Weekly schedule for ipad and Web function. Multiple sections in each day for a single unit or group. Automatically performs facility startstop control, operating mode, and temperature according to the set time schedule. Network Example CCM15 Can directly connect to the XYE port of indooroutdoor units. Can connect up to 64 indoor units. CCM03CCM30 is optional, and can be connected with CCM15 through F1F2E ports. The system comprises an AC system, data converter CCM15, router, cloud server and control terminal. Cloud Server Web PC Cloud Servers CCM15 Query and control a single unit or group. Weekly schedule setting: can set multiple sections in each day for a single unit or group. Group user control: you can use the same ID to manage hundreds of CCM15 when you select the As group user button on the login page. Laptop Internet Router LAN F1 F2 E Optional CCM30 X Y E Indoor units Max.64 Historical errors: easy service and management with a history error function. Intelligent Control iphone Pad The air conditioner can be remote controlled by a phone or tablet. Query and control the running state of the AC anytime, anywhere, and schedule queries and actions in advance. Remotely turn off the air conditioner to avoid wasting power. *If it connects to the XYE ports of the master ODU, the ODU must be set to auto addressing mode. Simply Control Interface Software control Cloud server control (WEB access). Click & Operate: the user-friendly interface. Allows single and group control. Simplified user control interface. Color indication and icons makes it easy to recognize unit status. Includes a full-screen display, and allows temperature adjustment by swiping

31 KNX Gateway Specially designed to allow monitoring and bidirectional control on the parameters and functionality of the TGM air conditioner from KNX installations MD-KNX What Is The KNX? Modbus Gateway KNX (Konnex) starts from KNX is the only global standard for housing and building control, and has been adopted by 70 of Europe s smart home market. LonWorks Gateway KNX Gateway Key Features Compatible with all TGM VRF products. External power is not required and direct connect to the KNX EIB bus Fully KNX interoperable, configuration from ETS Multiple objects for control (different types: bit, byte, characters ) Easy installation and directly connects with one indoor unit through the RS485 bus Directly connects to the KNX bus KNX certification Widely Applied TGM KNX protocol gateway can be combined with hundreds of KNX certified products labeled with the KNX trademark in the same working system. Smart panel Multi-functional controller Sensor Timing module Color touch screen BACnet Gateway KNX Bus OnOff switch Shade control Blind TGM KNX gateway Power module 220VAC What is the BMS? The Building Management System (BMS) (or Building Automation System (BAS)) is a computer-based control system installed in buildings. The BMS monitors the mechanical and electrical equipment such as ventilation, lighting, power, fire, and security. There are four types of common BMS protocols: BACnet, LonWorks, Modbus and KNX. Electrical Wiring Light Dimming light ShutterBlind TGM CAC system One gateway only can be connected to one indoor unit. Can only connect to the XYE port of the indoor unit. P Q E Indoor units KNX Control System Outdoor unit XYE XYE XYE P Q E KNX gateway KNX gateway KNX gateway KNX Bus 85 86

32 TM Quick & Easy Installation BACnet Gateway Each port can connect to IDUODU XYE ports or outdoor units K1K2E ports. Each port can also connect to one CCM03 or one CCM02 through F1F2E ports. Integrated Control System for Seamless Connection between VRF and BMS Systems MD-CCM08 CCM30 X Y E X Y E X Y E Indoor units What is the BACnet? MD-CCM08 BACnet is a communications protocol for building automated control networks. BACnet was designed to allow building automation and control systems for applications to communicate; e.g., heating, ventilation, air conditioning control, lighting control, access control, and fire detection systems and their associated equipment. TCPIP HUB F1 F2 E BACnetIP protocol X Y E F1 F2 E X Y E X Y E Outdoor units P Q E X Y E Indoor units Key Features Precise and efficient monitoring and control of the TGM VRF system Connect up to 256 indoor units or 128 outdoor units to the BMS Choose whether or not to connect to the BMS Built-in WEB function Web monitoring system BACnet BMS CCM02 K1 K2 E Outdoor units P Q E Indoor units BTL certification *If it connects to XYE ports of the master ODU, the ODU must be set to auto addressing mode. Controlling Operation mode setting Temperature setting Fan speed setting Swing running for web Monitoring Operation mode status report Set temperature status report Fan speed status report RC locking status Wide Compatibility CCM08 adapts very well to the BMS 1 Company SIMENS BMS software APOGEE Brand APOGEE A N Y W H E R E Lock remote controller Online quantity 2 TRANE Tracer Summit Timer status TRACER SUMMT Error status 3 Honeywell Alerton Room temperature display 4 Schneider Andover *For more information, refer to the product object table. 5 Johnson METASYS Monitoring Units Online Specifications MD-CCM08 allows users to track units' running status and change their running parameters on Internet Explorer for maximum control convenience. MD-CCM08 AC 220V~5060Hz Dimensions (HxWxD)( mm)

33 Network Example LonWorks Gateway Connection method 1: suitable for all air conditioning systems and can connect up to 64 indoor units. LonGW64 Open network integration of VRF Monitoring and control functions into LonWorks networks RS485 X,Y,E X,Y,E X,Y,E X,Y,E What is the LonWorks? LonGW64 LonWorks BMS Max. 64 indoor units LonWorks (local operating network) is a networking platform specifically created to address the needs of control applications. The platform is built on a protocol created by Echelon Corporation for networking devices over media such as twisted pairs, Connection method 2: only suitable for the V4 plus system and can connect up to 64 indoor units. power lines, fiber optics, and RF. LonWorks networks are recognized worldwide as the de facto standard within the building control industry. LonWorks is used to automate various functions within buildings; e.g., energy management, fire life safety lighting and HVAC. Key Features LonGW64 RS485 X,Y,E System 1 P,Q,E Connect to use LonWorks protocol and TGM air conditioner protocol Compliance with LonMark protocol enables the management and control of AC system Control various types of equipment from the customer s own PC Connect up to 64 indoor units to the BMS Option for large projects Easy and fast installation System 2 P,Q,E Controlling Monitoring P,Q,E OnOff command Operation mode setting Operation mode status report Set temperature status report LonWorks BMS System N Up to 64 indoor units Temperature setting Fan speed status report Fan speed setting Onlineoffline status Online quantity *If it connects to XYE ports of the master ODU, the ODU must be set to auto addressing mode. Specifications Error status Room temperature display LonGW64E AC 220V~5060Hz Dimensions (HxWxD)( mm) *For more information, refer to the product network's variable charts. Power (V) 89 90

34 Network Example Modbus Gateway 1) TCP connection method Integrated Control System for Seamless Connection between VRF and BMS Systems CCM-18A What is the Modbus? Modbus is a serial communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with its programmable logic controllers (PLCs). Modbus is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems. Key Features Modbus BMS Supports Modbus protocol networks Bridges the TGM central AC system to the BMS Built-in WEB server function 2) RTU connection method Connect to the BMS system through TCPIP or RTU Connect up to 16 indoor or 64 indoor units and 4 outdoor units *The four outdoor units must be in the same system CCM-18A Controlling Monitoring Modbus RTU Modbus BMS Operation mode setting Temperature setting Operation mode status report Set temperature status report K1K2E XYE bus Outdoor units Fan speed setting Timer status Max.4 Fan speed status report RC locking status Onlineoffline status Error status P Q E K1 K2 E Room temperature display Indoor units Max.64 *For more information, refer to the Modbus product mapping table. *1. If it connects to XYE ports of the master ODU, the ODU must be set to auto addressing mode. 2. XYE and K1K2E must be connected hand by hand. Config AC System Via Web Specifications When the Modbus network is set, users can conveniently configure their AC network system online using different TCPIP browsers. CCM-18A Dimensions (HxWxD)( mm) AC 220V~5060Hz 91 92

35 Accessories Hotel Key Card Interface Module Installation Example Easy installation and remote controller or wired controller can control indoor units. Wired controller Wired controller MD-NIM05E MD-NIM05BE MD-NIM05 Key Features MD-NIM05 is specially designed for hotel guest rooms, restaurants and so on. It works with a hotel card system Simple, compact, and easy to operate; suitable for hotel rooms Key card cooperates with wired controller to control the AC Eliminates the need for high voltage power, making the device safe and reliable Includes a build-in auto-restart function Remote controller or wired controller can control indoor units Two types are available: MD-NIM05E and MD-NIM05BE Application Example Key card Electrical Wiring For MD-NIM05E, users need to buy a high voltage relay for installation. MD-NIM05B For MD-NIM05BE, it can be directly connected to the hotel card-insert system (AC 220V) without a high voltage relay. The unit can be turned on or off when inserting or removing the key card. When the key card is in place, the air conditioner is activated. When the key card is removed, the system can remember the previous setting and stop operation. If the key card is reinserted, the unit enters standby or runs in the same state as the previously. It can stop cooling an unoccupied room to save energy. Wired controller Wired controller 220V KM 220V Key card AC contactor Key card Specifications MD-NIM05E MD-NIM05BE ON OFF Dimensions (H W D) (mm) Power (V) DC 5V (Supplied by indoor unit) AC 220V 93 94

36 Infrared Sensor Controller 3-Phase Protector Infrared sensors can induct human activities in certain areas. Indoor units will be HWUADPB71CM48 automatically turned on or off by sensing if the room is unoccupied. It is suitable for hotels, offices, conference rooms, residences, etc. Automatically adjusts the room environment. Automatically extends the shut down time to avoid frequent ONOFF. Stylish appearance accommodates itself to different buildings. MD-NIM09 Detects power status and takes protective action to stop the compressor from being damaged. Automatically distinguishes abnormal power supply conditions and automatically recovers. Excellent Reliability HWUA DPB71CM48 Accurate & Comfortable Sensor It detects motion and automatically starts the air conditioner if motion is detected. This function will save energy since it minimizes unnecessary energy usage by powering off when the area is empty. The infrared sensor can be installed on the ceiling or wall of well-used areas. The protector protects the entire system from power supply problems, and auto restarts after recovery. Specifications With overunder voltage function Without overunder voltage function HWUA DPA53CM23 HWUA DPB71CM48 DPA51CM44 220~480V-3N 5060Hz 208~480V-3N 5060Hz 220~480V-3N 5060Hz 380~480V-3N 5060Hz 208~480V-3N 5060Hz Temp. range -20 C~50 C 50Hz: -20 C~60 C 60Hz: -20 C~50 C -20 C~50 C -20 C~50 C 50Hz: -20 C~60 C 60Hz: -20 C~50 C Rated operational power 2.9 VA 7 VA 2.9 VA 13 VA 13 VA Over voltage Under voltage Phase imbalance Dimensions(W H D)(mm) Digital Power Ammeter Install on the ceiling Installation Example Electrical Wiring Calculates power consumption. Does not need adjusting after long-term use. Corresponds one outdoor unit to one digital power meter. DTS634 DTS636 Wired controller Wired controller MD-NIM09 MD-NIM09 Remote controller or wired controller can control indoor unit. Infrared sensor controller Infrared inductive control box CN3 CN2 MD-NIM09E CN1 S1 Infrared sensor Display panel Network Display panel port module port Wired controller Indoor main board Remote controller Low Power Consumption The digital power meter consumes minimal energy. Voltage circuit: less than 2W10VA Current circuit: less than 2.5VA Indications & Installation LCD Impulse A phase B phase C phase mm long crack 131 The digital power meter is tested after manufacture so it can be immediately deployed and used on-site. The LED indicators and installation schematic are shown in the figure on the left. Specifications Specifications MD-NIM09 DTS634DTS636 Dimensions (H W D)(mm) Sensor part: , Control box: Dimensions (H W D)(mm) Power DC 5V (Supplied by indoor unit) Power (V) 200V-500V(5060Hz) 95 96

37 Indoor Unit Group Controller Remote Alarm Controller KJR-150A Simple Design KJR-32B Simple Design KJR-150A is a indoor group controller designed specifically for V4 plus indoor units. It can connect up to 16 indoor units through XYE ports. With a display panel connected to KJR-150A, signals from a wired controller and remote controller can control a group of indoor units simultaneously. All indoor units will run at the same setting parameters. You can also control indoor units separately in each room by remote controller. The indoor units will run as previously set. System Wiring Diagram KJR-32B is specially designed for engineering applications. It does not display the ODU s working parameters parameters. However, it can connect to the alarm device when the ODU is working abnormally, in which case the RUN light will flash. Specifications KJR-32B Dimensions (H W D)(mm) 85X150X70 Power (V) V(5060Hz) KJR-150A 1# V4+ indoor unit(1#) V4+ indoor unit (2#) V4+ indoor unit (3#) V4+ indoor unit N# (N 16) PQE V4+ Outdoor Unit Network Electricity Distribution Module X Y E X Y E X Y E X Y E X Y E XYE Simple Design External contact interface module MD-NIM10 PQE POWER Designed specifically for Mini VRF Provides the OAE ports for Mini VRF to connect with the IMM network control KJR-150A 16# V4+ indoor unit(1#) V4+ indoor unit (2#) V4+ indoor unit (3#) V4+ indoor unit N# (N 16) Centralized controller system, and distributes electricity across the network. Wiring Diagram X Y E X Y E X Y E X Y E X Y E * If you need to use a centralized controller, you can connect to the XYE from an outdoor unit. Note: Max. 64 indoor units OAE ports: connects to the OAE port of the ammeter. PQE ports: connects to the PQE port of the outdoor unit. Each port on M-interface gateway can only be connected with one MD-NIM10 through K1K2E ports. MD-NIM10 Specifications KJR-150A K1 K2 E OAE PQE PQE Dimensions (HXWXD)(mm) 85X150X70 M-interface Power (V) V(5060Hz) Indoor units Ammeter 97 98

38 AHU Control Box Introduction AHU Kit can be used to connect VRF outdoor units with DX AHU or other brand indoor units with AC fan motor. A Series and B Series are supplied. These can connect with the TGM VRF System (except V4+R& V5 Series). The A Series is an independent control box. For the B Series, up to four control boxes can be combined. The capacity reaches up to 224 (80HP), and it s easy to create a solution for large projects. Wiring Example PQE T1T2T2BT2C AHUKZ-01A AHUKZ-02A AHUKZ-03A XYE AHUKZ-01B AHUKZ-02B AHUKZ-03B Centralized Controller Wired Controller Selection Software To meet consultants and distributors requirements, TGM has developed an advanced design automation tool that can be used in AutoCAD-based CAD version or Windows-based Sales version. The software provides quick and convenient selectable options for users, supports multiple languages, and greatly improves the selection process. Windows Version Load calculation: provides two calculation methods (detailed room load calculation and rough load calculation). Indoor & outdoor units: choose from versatile indoor units and different outdoor units. Piping drawing: displays the detailed layout of the AC system and the parameters for piping and branch distributors. Controller selection: provides a selection of controllers for indoor units and outdoor units, including wireless and remote controllers for indoor units. Report output: outputs a comprehensive selection report as a Word or PDF document. GL pipe Fanpump x EXV Specifications DX AHU or other brand indoor units AHUKZ-01AAHUKZ-02AAHUKZ-03A AHUKZ-01BAHUKZ-02BAHUKZ-03B Dimensions(H W D)(mm) Power (V) V~ 50Hz V~ 60Hz TGM Outdoor Unit Diagnosis Software Display the outdoor units real-time running conditions. Automatically outputs running status charts. Supports V3, V4, V4+, D3, D4, V4+S and V4+R outdoor units. CAD Version AutoCAD add-on software Automatic Calculation: refrigerant & drain pipe size Automatic Selection: distributor kit & branch joint System Check: installation regulations & adding refrigerant Automatic Report: piping installation diagram, equipment list & quotation Wiring Diagram The diagnostic software applies to K1, K2, E of the outdoor units. The corresponding wiring diagram is shown in the figure on the right. Recommended Config 485A-I K1,K2,E Operating system WIN XP SP4WIN 7 CPU HDD Interface port Pentium 4 2G or above 30G free space RS-232 terminal

39 APP Application TGM News APP TGM News APP has been developed to share E-news, new product information, training information and product catalogs. TGM CAC News Application ios Version HRV-Heat recovery ventilator Larger air supply rate enhanced heat exchange efficiency enhanced energy saving property The heat recovery ventilator (HRV) can reclaim heat energy lost through ventilation and reduce the room temperature fluctuation caused by ventilation process. By utilizing the most advanced technology and technics, TGM HRV has extremely good performance. The heat exchanged core is made of special paper processed with chemical treatment, which could realize better temperature and humidity control of the room environment. Temperature exchange efficiency is above 65 and enthalpy exchange efficiency between HRV-200 HRV-300 HRV-400 HRV-500 HRV-800 HRV-1000 Names HRV-1500 HRV-2000 RA (Returm air from room) HRV TGM After-service APP TGM CAC After-service APP is very useful for engineers who serve for TGM commercial air conditioner. It will be very convenient to do the commissioning, refrigerant charge and troubleshooting. Heat Moisture Cold air 0 0 C EA 6 C Heat SA 14 C Moisture Warm air 20 C SA (Supply air to room) TGM CAC After-service Application Heat exchange plate EA (Exhaust air to outdoors) OA (Fresh air from outdoors) Android Version Low noise Sound proof material is used to guarantee quiet operation. Compact design, flexible installation and easy maintenance ios Version With a min. height of only in.(264mm) and 50lbs(23kg) weight, the unit provides best convenience and possibility for installation in limited spaces in.(264mm)

40 HRV Multi-modes for different situations Heat exchange mode When air flow formed by the fans goes through the heat exchanged core in cross way, due to temperature difference between two channels of the core, thermal transmission happens naturally. In summer days, high temperature outdoor air gets cooled by indoor exhaust air; in winter, low temperature outdoor air gets heated by indoor exhaust air. So the energy contained in exhaust air can be reclaimed and energy efficiency gets improved. Bypass mode In mild climate areas or seasons, when temperature and humidity level difference between indoor and outdoor is small, the unit works as conventional ventilation fan. Both supply fan and exhaust fan works at the same speed (Himidlowauto). Air supply mode It is one kind of bypass mode with air supply fan speed higher than exhaust fan speed. It can be used in mild climate area where large amount fresh air is needed. Exhaust air mode It is also one kind of bypass mode with exhaust fan speed higher than air supply fan speed. It can be used in mild climate area where large amount exhaust air needs to be expelled. Flexible control Interlocking control with other indoor units by controller is possible. Wired control KJR-27B OA IDU SA EA IDU Heat exchange mode EA OA EA Bypass mode OA Auto mode Element Element Damper Damper The controller chooses heat exchange mode or bypass mode according to the temperature difference between outdoor and indoor temperature. Both the two fans work at low speed. SA Duct (Obtain locally) RA RA SA RA SA Specifications Cooling Heating Sound pressure level Temperature exchange efficiency Enthalpy exchange efficiency Temperature exchange efficiency Enthalpy exchange efficiency Heat exchange mode Bypass mode Net dimension (W D H) Packing size (W D H) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low Netgross weight Casing Heat exchange system Heat exchange element material Type High Airflow rate Medium Fan Low High ESP Medium Low Motor output Duct diameter Operating temperature range Cooling Heating Sound pressure level Temperature exchange efficiency Enthalpy exchange efficiency Temperature exchange efficiency Enthalpy exchange efficiency Heat exchange mode Bypass mode Net dimension (W D H) Packing size (W D H) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low Netgross weight Casing Heat exchange system Heat exchange element material Type High Airflow rate Medium Fan Low High ESP Medium Low Motor output Duct diameter Operating temperature range VPhHz db(a) db(a) db(a) db(a) db(a) db(a) mm inch mm inch kg(lbs) m 3 h(cfm) m 3 h(cfm) m 3 h(cfm) Pa Pa Pa W C F VPhHz db(a) db(a) db(a) db(a) db(a) db(a) mm inch mm inch kg(lbs) m 3 h(cfm) m 3 h(cfm) m 3 h(cfm) Pa Pa Pa W C F HRV ( ) 400(235.6) 400(235.6) 300(176.7) Φ144(5-58) HRV ( ) 1000(588.2) 1000(588.2) 750(441.2) Φ242(9-12) HRV ( ) Galvanized steel plate Air to air cross flow total heat (sensible heat + latent heat) exchange Specially processed nonflammable paper Centrifugal fan 500(294.5) 500(294.5) 375(220.8) Φ194(7-58) -7~43 DB, 80 RH or less 19.4~109.4 DB, 80 RH or less HRV ( ) Galvanized steel plate Air to air cross flow total heat (sensible heat + latent heat) exchange Specially processed nonflammable paper Centrifugal fan 1500(882.4) ( ) -7~43 DB, 80 RH or less 19.4~109.4 DB, 80 RH or less HRV ( ) 800(471.1) 800(471.1) 600(353.4) Φ242(9-12) HRV ( ) 2000(1176.5) ( ) HRV Note: 1. For the units model of HRV ( ), there are 3-speed adjustable air volume (Hi, Med, Low), but for the units model of HRV ( ), there are only 1-speed which cannot be adjusted. 2. Sound level is measured at 1.4m below the center of the body in an anechoic chamber. 3. Efficiency is measured under the following conditions: * Cooling Condition: Air Exhaust Temp. 27 C(80.6 o F) DB,19.5 C(67.1 o F) WB., Fresh Air Temp. 35 C(95 o F) DB,28 C(82.4 o F) WB. * Heating Condition: Air Exhaust Temp. 21 C(69.8 o F) DB,13 C(55.4 o F) WB., Fresh Air Temp. 5 C(41 o F) DB,2 C(35.6 o F) WB

41 Branch Pipe Branch joints of two-pipe refrigerant system Branch joints of three-pipe refrigerant system Appearance name Packing Size in.(mm) Gross Weight Ibs.(kg) Description Appearance name Packing Size in.(mm) Gross Weight Ibs.(kg) Description FQZHW-02N1D ( ) 3.3(1.5) For two outdoor units connection FQZHW-02SB ( ) 4.84(2.2) For two outdoor units connection Branch joint for 410A outdoor unit FQZHW-03N1D ( ) 7.48(3.4) For three outdoor units connection Branch joint between outdoor unit FQZHW-03SB ( ) 11(5.0) For three outdoor units connection FQZHW-04N1D ( ) 10.56(4.8) For four outdoor units connection FQZHW-04SB ( ) 16.5(7.5) For four outdoor units connection BRANCH PIPE FQZHN-01D ( ) 0.88(0.4) A*<16.6 FQZHN-01SB ( ) 1.76(0.8) A*<16.6 BRANCH PIPE FQZHN-02D ( ) 1.32(0.6) 16.6 A*<33 Branch joint between MS unit and outdoor unit FQZHN-02SB FQZHN-03SB ( ) ( ) 1.98(0.9) 3.08(1.4) 16.6 A*<33 33 A*<66 Branch joint for R410A indoor unit FQZHN-03D ( ) 1.98(0.9) 33 A*<66 FQZHN-04SB ( ) 5.06(2.3) 66 A*<92 FQZHN-04D ( ) 3.3(1.5) 66 A*<92 FQZHN-05SB ( ) 7.26(3.3) Description 92 A* FQZHN-05D ( ) 4.18(1.9) 92 A* Branch joint between MS unit and indoor unit FQZHN-01D ( ) 0.88(0.4) A*<16.6 A*:The total capacity of indoor units which is connected to this branch joint A*:The total capacity of indoor units which is connected to this branch joint

R410A VRF Indoor Unit 50Hz AC Series

R410A VRF Indoor Unit 50Hz AC Series Commercial Air Conditioners 2016 Commercial Air Conditioner Division Midea Group R410A VRF Indoor Unit 50Hz AC Series Midea CAC After-service Application Midea CAC News Application Add.: West Region of

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15 Midea VRF (V+) V+S (Heat Pump) V+i (Individual) (Heat Pump) V+R (Heat Recovery) MVRF 05/5 Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit

More information

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Coercial Air Conditioners 2016 VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group 1602-2V1510 Coercial Air Conditioners 2016 VRF 50Hz V+K/V+S/V+R/V+W/V+I/Mini VRF Midea CAC After-service Application Midea CAC News Application Coercial Air Conditioner Division Midea Group Add.: West

More information

Ultimate VRF System R410A, 50Hz

Ultimate VRF System R410A, 50Hz Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,

More information

VARIABLE REFRIGERANT FLOW SYSTEMS

VARIABLE REFRIGERANT FLOW SYSTEMS VARIABLE REFRIGERANT FLOW SYSTEMS Index VRF System - Outdoor Units 11 Indoor Units: Cassettes 55 Indoor Units: Duct 63 Indoor Units: Wall, Ceiling, Floor 71 Control Systems 85 Heat Recovery Ventilator

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data VANJSKE JEDINICE Variable Refrigerant Flow Systems *Preliminary data Index Key Features 0 Outdoor Units 5 Indoor Units 86 Control Systems Central Control Software 8 Accessories Heat Recovery Ventilator

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units Coercial Air Conditioners 07/08 INVERTER DC Inverter Aqua Mini Chillers & Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016. Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual LCAC/2016.1 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Part 1. General Information... 1 1. Nomenclature...

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

DC inverter VRF presentation

DC inverter VRF presentation DC inverter VRF presentation NINGBO DEKON REFRIGERATION EQUIPMENT CO., LTD Wangchun Industrial Park, Yinzhou district,ningbo, China. Tel: 0086-574-88152763 Mob: 0086-15356475680 www.dekon-hvac.com Email:

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

2017 LINE UP MINI SPLITS CATALOG

2017 LINE UP MINI SPLITS CATALOG SINGLE ZONE MULTI ZONE LIGHT COMMERCIAL 2017 LINE UP MINI SPLITS CATALOG Residential & Light Commercial Solutions WELCOME SERVICE & SUPPORT We believe that the best way to ensure the complete satisfaction

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

Contents. Introduction. Full DC Inverter VRF 2. Small Capacity Units 5. Advantage 7. Benefits 12. DX-LINE Mini 28. Indoor Units 32

Contents. Introduction. Full DC Inverter VRF 2. Small Capacity Units 5. Advantage 7. Benefits 12. DX-LINE Mini 28. Indoor Units 32 Contents Full DC Inverter VRF 2 Small Capacity Units 5 Advantage 7 Benefits 12 DX-LINE Mini 28 Indoor Units 32 Controllers and Software 48 Introduction If you re considering replacing the HVAC system in

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. Kaden Ducted Air Conditioners Creating the ideal climate in different rooms throughout your home is essential for your family s comfort. Whether it s a

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA A GUIDE TO COMFORT HITACHI INVERTER SPLIT SYSTEMS Enjoy the Silence with Quiet Mode With Hitachi, noisy air conditioners are a thing of the past. Our modern Full Flat design has ensured efficient yet ultra-quiet

More information

YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST Table of Contents Serving your needs since 1874 1 Product Benefits 3 Product Features 4 Product Functions 6 Product Technologies

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Evaporadoras Hidrónicas

Evaporadoras Hidrónicas Evaporadoras Hidrónicas Rev. 215-6-4 Rev. 214-9-5 Clima-Flex, S.A. de C.V. Av. Central # 285 Parque Logístico - Delegación La Pila C.P. 78422, San Luis Potosí, México Tel. 52 (444) 161-543 /ClimaFlexMexico

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS 2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS Midea Company Profile Established in 1968, Midea Group has grown into a leading consumer appliances and HVAC systems manufacturer. With over 8,000 employees,

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Air Conditioning. Air Conditioning. VRF systems

Air Conditioning. Air Conditioning. VRF systems Air Conditioning Air Conditioning VRF systems Systemair Trust We consider your trust in us as a supplier an important goal. It is always included in our work on all levels and in all areas whether it is

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

R410 VRF Indoor Unit 50Hz

R410 VRF Indoor Unit 50Hz COMMERCIL IR CONDITIONERS R410 VRF Indoor Unit 50Hz Coercial ir Conditioner Business Units Midea Group dd: est region of Midea coercial air conditioner department, Industry venue, Beijiao, Shunde, Foshan,

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Ceiling Mounted Cassette Unit

Ceiling Mounted Cassette Unit Brochure AP-MCK-13 Ceiling Mounted Cassette Unit Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS Now Only One Unit Required for Initial Start-up L Multi Zone Inverter Heat Pump High Efficiency Multi 21+ heat pump units can heat and cool up to 5 zones without

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series FSKMIF-71AE2-EU FSKMIF-91AE2-EU FSKIF-121AE2-EU FSKMI-181AE2-EU FSLMIF-71AE2 FSLMIF-91AE2 FSLIF-121AE2 FSLMI-180AE2

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG. Variable Refrigerant Flow Solutions. TOSOT VRF Catalog 1

HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG. Variable Refrigerant Flow Solutions. TOSOT VRF Catalog 1 HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG Variable Refrigerant Flow Solutions TOSOT VRF Catalog 1 WHY CHOOSE T-VRF IN AMERICA? Local Representation: We decided

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

HEAT PUMPS. Efficient Comfort For Every Season

HEAT PUMPS. Efficient Comfort For Every Season HEAT PUMPS Evergreen Series Efficient Comfort For Every Season 1 Evergreen Series Efficient Comfort For Every Season THE WORLD S MOST EFFICIENT HEAT PUMP The Yukon series is rated the world s most efficient

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

R410A50Hz Universal Outdoor Series Technical Manual

R410A50Hz Universal Outdoor Series Technical Manual Outdoor Unit R410A 50Hz Universal Outdoor Series Technical Manual 2013 Version LCAC/2.0/201308 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Content PART 1.General Information... 1 1.Nomenclature...

More information

A more comfortable, safe and sustainable world

A more comfortable, safe and sustainable world YORK RAC, PAC & VRF 2017 A more comfortable, safe and sustainable world RAC, PAC & VRF Air-conditioning solutions Every market is unique in air-conditioning requirements. In this catalogue our customers

More information

Geniuses at work. Residential Mini Splits

Geniuses at work. Residential Mini Splits Residential Mini Splits Smart Pearl Smart Whisper Geniuses at work. Two smart ways to heat and cool your home. Be the smartest person in the room when you get your home equipped with a Wi-Fi enabled heat

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 200 Air Conditioning System 200 Air Conditioning System Enjoy a clean

More information

All DC Inverter Multi VRF

All DC Inverter Multi VRF All DC Inverter Multi VRF In 2012, Gree highly promoted GMV5 All DC Inverter Multi VRF New breakthrough in comfort ability, intelligent control and design. Eight prominent advantages More powerful product

More information

Ducted inverter reverse cycle air conditioning

Ducted inverter reverse cycle air conditioning Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling

More information

THE WORLD S MOST EFFICIENT HEAT PUMP

THE WORLD S MOST EFFICIENT HEAT PUMP HEAT PUMPS THE WORLD S MOST EFFICIENT HEAT PUMP The LOMOPLUS is rated the world s most efficient heat pump in both cooling and heating modes and also in every capacity from 9,000 BTU to 24,000 BTU. Being

More information

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T. L E N N O X MINI-SPLIT THE SOLUTION THAT WORKS WHERE OTHERS WON T. LENNOX MINI-SPLIT OFFER YEAR-ROUND COMFORT AND PERFORMANCE. Energy-efficient operation and easy installation make Lennox Mini-Split Systems

More information

VENTILATION. Effective heat exchange and fresh air ventilation

VENTILATION. Effective heat exchange and fresh air ventilation VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU CASSETTE DUCT TYPE FLOOR CEILING Light Commercial 18K BTU - 48K BTU 1-to-1 COMMERCIAL SERIES About our products The Tosot 1-to-1 commercial series of Air Conditioners was designed for applications where

More information

Lennox Mini-Split Systems Year-Round Comfort and Performance

Lennox Mini-Split Systems Year-Round Comfort and Performance Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

Ceiling Mounted Cassette Unit

Ceiling Mounted Cassette Unit CEILING CASSETTE A5CK-E SERIES - R410A COOLING ONLY A5CK20E A5CK25E A5CK28E A5CK40E A5CK40E A5CK40E A5CK40E A5CK50E A5LC20C A5LC25C A5LC28C A5LC35D A5LC35D A5LC40D A5LC40D A5LC50D Btu/hr 18300 22200 27000

More information

COOLING, COMFORT AND CONVENIENCE

COOLING, COMFORT AND CONVENIENCE AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE DUCT FREE MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS Why choose a Mini-Split system? Installing

More information

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle AUTO ILLE ELEVATION GR ED CAN BE LOWER UP TO 4M Better Design Super slim design, perfect for tight roof spaces 360 round flow, ensuring uniform airflow distribution across the room Independent louvre control

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units AIR CONDITIONERS 2017 COLLECTION Window Portable Dehumidifier Through The Wall Ductless Split Units 2017 COLLECTION AIR CONDITIONERS Stay comfortable in any room with an Air Conditioner unit that finally

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information

Product Brochure Smart Power. Low Profile Ducted

Product Brochure Smart Power. Low Profile Ducted Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers

More information

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE. LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE. LENNOX MINI-VRF MAKES MULTI-ZONE COMFORT EASY AND EFFICIENT. Available in 3- to 5-ton configurations, with options to control up to 9 zones,

More information

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS The latest innovation in cool 7 YEAR WARRANTY ON COMPRESSORS 1 YEAR WARRANTY ON PARTS Engineered to be both aesthetically pleasing and energy-efficient, Katashi air conditioning units bring the latest

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

(Non-Inverter & Inverter) R410A

(Non-Inverter & Inverter) R410A LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter

More information

Variable Refrigerant Flow (VRF) Multi-Zone Systems

Variable Refrigerant Flow (VRF) Multi-Zone Systems Variable Refrigerant Flow (VRF) Multi-Zone Systems Commercial Catalog 2016 One System - Up to 36 Zones Easy Installation Quiet Operation Energy Efficient Compact Modular Design Smart technology for efficient

More information

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

Air conditioning. VRF systems

Air conditioning. VRF systems Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air conditioning VRF systems Systemair Trust We consider your trust in us as

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

SUPERIOR COMFORT FOR THE GLOBAL MARKETPLACE

SUPERIOR COMFORT FOR THE GLOBAL MARKETPLACE DUCTLESS SPLIT MULTI DUCTLESS SPLIT PACKAGED TERMINAL (PTAC) THROUGH-THE-WALL (TTW) SUPERIOR COMFORT FOR THE GLOBAL MARKETPLACE A I R C O N D I T I O N I N G SUPERIOR COMFORT FOR THE GLOBAL MARKETPLACE

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information