Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

Size: px
Start display at page:

Download "Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units"

Transcription

1 Coercial Air Conditioners 07/08 INVERTER DC Inverter Aqua Mini Chillers &

2 Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and air conditioning solutions. Midea CAC has continued with the tradition of innovation upon which it was founded, and emerged as a global leader in the HVAC industry. A strong drive for advancement has created a groundbreaking R&D department that has placed Midea CAC at the forefront of a competitive field. Through these independent efforts and joint cooperation with other global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide. Midea Company Introduction Midea CAC Introduction

3 There are three production bases: Shunde, Chongqing and Hefei. MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU. MCAC Chongqing: 4 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled Screw/Scroll Chillers, and AHU/FCU. MCAC Hefei: product lines focusing on VRF, Chillers, and Heat Pump Water Heaters. 06 Strategic alliance between Midea and Italy s Clivet 05 JV with Carrier in China in chiller field, launched the unitary all DC inverter type Aqua Mini Chiller 04 Launched the DC Inverter 03 Launched the super high efficiency centrifugal chiller with full falling film technology 0 Formed Midea-Carrier JV.Company in India and HK 00 Built the 3rd manufacturing base in Hefei 009 Launched the unitary fixed type Aqua Mini Chiller 008 Launched the split digital type Aqua Mini Chiller 006 Launched the first VSD centrifugal chiller 004 Acquired MGRE entered the chiller industry 00 Cooperated with Copeland to develop the digital scroll VRF system 000 Developed the first inverter VRF with Toshiba 999 Entered the CAC field

4 Aqua Mini Chiller Reference Projects Hotel ASEM Resort Villa Five Star Sheraton Bandara Resort Hotel Five Star Aston Kuta Bali Hotel Five Star Residential Vanke Estate Rancho Santa Fe Villas Al Sila'a Emirati Housing Development 448 Villas Agile Estate Clear Water Bay 03

5 INVERTER Aqua Mini Chiller Contents Aqua Mini Chiller Features Specifications Unit Dimensions Cassette Series Duct Series Wall Mounted Ceiling & Floor Dimensions Control Devices Accessories Application of Central Control & BMS Control Selection Software 04

6 Aqua Mini Chiller Aqua Mini Chiller Midea DC Inverter Air-cooled Mini Chiller has unitary structure design and hydraulic module is built in the outdoor unit. It is air-cooled water heat pump chiller so there is no need of cooling water tower at the condensing side. DC inverter Mini chillers cooling capacity range is from 5 to 8 and it can freely combine with fan coil units and floor heating. These units are designed for residential applications or light coercial applications that require cold or hot water. They are silent and compact units, easy to install and maintain. All units energy efficiency at part load is A + rated. Their high energy efficiency and high reliability ensure low running cost. So they are widely applied in apartments, villas, small business office buildings as well as restaurants, etc. Product Lineup Capacity () Appearance Power Supply 0-40V/Ph/50Hz V/3Ph/50Hz 08-30V/Ph/60Hz 05

7 Aqua Mini Chiller Nomenclature M G C - V 6 W / D R N Refrigerant type N: R40A Power Supply R: V/3Ph/50Hz None: 0-40V/Ph/50Hz D: DC compressor and fan motor Outdoor Unit Nominal Cooling Capacity () Compressor V: Inverter scroll compressor Design Series Code C: Unitary chiller Light Coercial Chiller System Midea 06

8 Aqua Mini Chiller Features Wide application range Nine models with cooling capacities from 5 to 8 and heating capacities from 5.5 to 8.5. Multiple power supply options. Freely combine with fan coil units and floor coils. Home owners may choose the best types according to their design taste (for interior) or functional needs. 4 way cassette Ceiling & floor Compact 4 way cassette Duct Wall mounted Wide operation temperature range -5 C COOLING MODE 46 C HEATING MODE -5 C 7 C C(D.B.) Outdoor temp. Wide range of outlet water temperature The water outlet temperature is 4-55 C. 07

9 A + rated energy efficiency at part load The DC inverter chiller integrates the latest technological innovations and ensures precise temperature regulation and highly efficient energy usage, making a significant contribution to the limiting the impact on the environment. Aqua Mini Chiller DC inverter compressor Twin rotary DC inverter compressor is used. The output of the outdoor unit can be adjusted precisely according to the energy demanded. High efficiency DC motor: - Creative motor core design - High density neodymium magnet - Concentrated type stator - Wider operating frequency range Better balance and Extremely Low Vibration: - Twin eccentric cams - balance weights Compressor (Twin Rotary) structure Highly Stable Moving Parts: - Optimal material matching rollers and vanes - Optimize compressor drive technology - Highly robust bearings - Compact structure DC fan motor High efficiency DC fan motor saved power up to 50%. Motor speed(rpm) DC inverter stepless adjustment AC inverter multistep adjustment System pressure High performance heat exchanger Reduce air resistance New design Original design High efficiency inner-threaded pipe, enhance heat transfer. Hydrophilic fins + inner-threaded pipes The new designed window fins enlarge the heat-exchanging area, decrease the air resistance, save more power and enhance heat exchange performance. Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency. The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures a longer coil service life. 08

10 Aqua Mini Chiller Advanced technology DC inverter technology, optimally designed fan shape and air discharge grille ensure low sound values. Air deflector Grille Fan Powerful Large Propeller Newly Designed Fan Guard EXV is used for stable and accurate gas flow control. Refrigerant inlet High efficiency plate heat exchanger Water outlet Plate heat exchanger uses metal plates to transfer heat between refrigerant and water. The fluids are exposed to a much larger surface area because the fluids spread out over the plates, so both heat transfer efficiency and heat exchanger speed are greatly improved. Multi protections including voltage protection, current protection, anti-freezing protection and water flow protection ensure system Water inlet safety running. Refrigerant outlet High efficiency water pump The water pump used is compliance with Erp directive, which is A degrade efficiency standard. Easy installation Compact structure design and leak-tight refrigerant circuit save you much installation labor. The chillers are equipped with a hydronic module integrated into the unit chassis, limiting the installation to straight-forward operations like connection of the power supply, the water supply and the air distribution FCUs. The units are equipped with axial fans so they can be installed directly outdoors. Air purge valve Plate heat exchanger Pressure relief valve Hydraulic module Water pump Water pressure differential valve Expansion tank 09

11 Easy control Remote ON/OFF and remote cool/heat functions. Aqua Mini Chiller Controller built-in in unit panel used to perform all related operations as the user interface as well as fast diagnosis of possible incidents and their history. ON/OFF & Mode selection Temperature adjust Timer setting Fast diagnosis Optional wired controller for easy operation. Touch key operation LCD displays operation parameters Multiple timers Real-time clock Note: When the wired controller is connected, the built-in controller is only for display, check and diagnosis functions. 0

12 Aqua Mini Chiller Specifications 0-40V/Ph/50Hz Power supply Cooling Cooling Heating 3 Heating 4 Compressor Air heat exchanger V/Ph/Hz MGC-V5W/DN MGC-V7W/DN MGC-V0W/DN MGC-VW/DN 0-40//50 Capacity 5.0(.9-5.8) 7.0(.-7.8) 0.0(.9-0.5).(3.-.0) Rated input Rated current A Capacity Rated current EER Capacity 6.(.-7.0) 8.0(.3-9.0).0(3.-.0).3(3.3-3.) Rated input Rated current A COP Capacity Rated current COP SCOP Seasonal space heating energy efficiency (ηs) Seasonal space heating energy efficiency class Max. input current Outdoor fan Water heat exchanger Motor type % 35.3% 30.7% 35.4% A+ A+ A+ A+ A Rotary DC Motor Air flow m 3 /h 5,00 5,00 7,000 7,000 Fin-coil Plate heat exchanger Water volume L Water flow m 3 /h Pump head m Water pump Water volume L/min Expansion tank volume L 3 3 R40A Refrigerant Charged volume Throttle type EER SEER Sound power level Sound pressure level 5 Unit net dimension (W H D) Packing dimension (W H D) Net/ The Max. and Min. wate rinlet pressure 6 Electronic expansion valve , ,37 400,0,00 435,0,00 435,08, ,08, /9 8/9 0/ 0/ 500/50 Pipe connections Water inlet/outlet inch -/4 -/4 Controller Electronic controller (standard), wired controller (optional) Ambient Cooling C temperature range Heating C -5-7 Water outlet Cooling C 4-0 temperature range Heating C Nominal capacity is based on the following conditions:. Condenser air in 35 C. Evaporator water in/out /7 C. Condenser air in 35 C. Evaporator water in/out 3/8 C 3. Evaporator air in 7 C C85% R.H., Condenser water in/out 40/45 C 4. Evaporator air in 7 C C85% R.H., Condenser water in/out 30/35 C 5. At m in open field fan side (sound pressure) 6. The maximum and minimum operating pressure values refer to the activation of the pressure switches 7. The above data test reference standard EN45:03; EN485:03; EN50564:0; EN0:0; (EU)No:8:03; (EU)No:83:03; OJ 04/C 07/0:04

13 380-45V/3Ph/50Hz MGC-VW/DRN MGC-V4W/DRN MGC-V6W/DRN Power supply V/Ph/Hz / 3/50 Capacity.(3.-.0).5( ) 4.5( ) Rated input Cooling Rated current A EER SEER Capacity Cooling Rated input W EER Capacity.3(3.3-3.) 3.8( ) 6.0( ) Rated input Heating 3 Rated current A COP Capacity Rated input Heating 4 COP SCOP Seasonal space heating energy efficiency (ηs) 43.5% 48.3% 3.6% Seasonal space heating energy efficiency class A+ A+ A+ Max. input current A Compressor Rotary Outdoor fan Motor type DC motor Air flow m 3 /h 7,000 7,000 7,000 Air heat exchanger Fin-coil Plate Water heat Water volume L exchanger Water flow m 3 /h Water pump Pump head m Water volume L/min Expansion tank volume L Refrigerant R40A Charged volume Throttle type Electronic expansion valve Sound power level Sound pressure level Unit net dimension (W H D) 970, Packing dimension (W H D),08, Net/ 0/ / / The Max. and Min. water inlet pressure 6 500/50 Pipe connections Water inlet/outlet inch -/4 Controller Electronic controller (standard), wired controller (optional) Ambient Cooling C temperature range Heating C -5-7 Water outlet Cooling C 4-0 temperature range Heating C Nominal capacity is based on the following conditions:. Condenser air in 35 C, Evaporator water in/out /7 C. Condenser air in 35 C, Evaporator water in/out 3/8 C 3. Evaporator air in 7 C C85% R.H., Condenser water in/out 40/45 C 4. Evaporator air in 7 C C85% R.H., Condenser water in/out 30/35 C 5. At m in open field fan side (sound pressure) 6. The maximum and minimum operating pressure values refer to the activation of the pressure switches 7. The above data test reference standard EN45:03; EN485:03; EN50564:0; EN0:0; (EU)No:8:03; (EU)No:83:03; OJ 04/C 07/0:04 Aqua Mini Chiller

14 Aqua Mini Chiller 08-30V/Ph/60Hz MGC-V0W/DVN MGC-V8W/DVN Power supply V/Ph/Hz 08-30//60 kbtu/h 36.0( ) 58.0( ) Capacity 0.0(.9-0.5) 7.0( ) Cooling Input EER Heating kbtu/h 38.0(.0-4.0) 63.0( ) Capacity.0(3.-.0) 8.5( ) Input COP Max. input current Compressor A Rotary Outdoor fan Motor type DC motor Air flow CFM(m 3 /h) 4,0(7,000) 4,0(7,000) Air heat exchanger Fin-coil Plate Water heat exchanger Water volume L Water flow CFM(m 3 /h).0(.7).7(.9) 8 3 Water pump Expansion tank volume Refrigerant Throttle type Sound pressure level 3 Pump head m 8 8 Water volume L/min 4 4 L 3 3 R40A Charged volume lbs/ 6./.8 7.5/3.4 Electronic expansion valve Unit net dimension (W H D) Packing dimension (W H D) inch inch 38-3/6 5-/4 3-/ 970, /3 57-/64 7-/8,08, Net/ lbs 43/67 47/7 0/ /3 The Max. and Min. wate rinlet pressure 4 500/50 Pipe connections Water inlet/outlet inch Controller -/4 Electronic controller (standard), wired controller (optional) Ambient temperature range Water outlet temperature range Cooling C Heating C Cooling C Heating C Cooling: Chilled water inlet/outlet temperature: /7 C, outdoor ambient temperature 35 C DB.. Heating: Warm water inlet/outlet temperature: 40/45 C, outdoor ambient temperature 7 C DB/6 C WB. 3. At m in open field fan side (sound pressure). 4. The maximum and minimum operating pressure values refer to the activation of the pressure switches. 3

15 Unit Dimensions (Unit: ) 5/7 Aqua Mini Chiller

16 Midea DC operate in high efficiency and low sound level due to the DC brushless fan motor. It contains cassette units, ceiling & floor units with or without cabinet, wall-mounted units and duct units. The air volume ranges from 50CFM to 500CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and various other applications. 5

17 Nomenclature M K T3 - V 00 Nominal Air Volume (CFM) DC Series Code Chilled Fan Coil Unit Midea 6

18 Advantage of with DC Brushless Fan Motor The DC fan coil units are the new energy saving products improved with advanced DC driven technology. The DC fan coil units have advanced technology of high energy efficiency, low noise operation and precision temperature control, so are ideal for hospitals, office building, hotels, airports and various other applications. DC driven motor Energy Efficiency, Comply with CE Regulation The power consumption of DC driven fan coil units can be reduced up to 30% in comparison to corresponding AC type. Power input: W DC motor 00 AC motor Air Flow: CFM DC and AC motor s power contrast 7

19 Quiet Operation Unit noise is -5 lower compared to an AC motor fan coil unit, creating a quiet living environment. Quiet Constant Level of Air Temperature and Humidity The DC Inverter fan motor adjusts of air flow based on thermal load instantly providing less temperature fluctuation and an improved living environment. Temp Fluctuation of room temperature Time DC driven FCU AC driven FCU Versatile Selection Midea DC contain cassette units, ceiling & floor units with or without cabinet, wall-mounted units and duct units. The air volume ranges from 50CFM to 500CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and various other applications. Cassette unit Wall-mounted unit Duct unit Ceiling & floor unit with cabinet Ceiling & floor unit with cabinet Ceiling & floor unit without cabinet 8

20 Product Lineup -Pipe FCUs Air volume (CFM) way cassette Compact 4-way cassette Duct Wall mounted Ceiling & floor 4-Pipe FCUs Air volume (CFM) way cassette Compact 4-way cassette Duct Note: The standard power supply for all fan coil units is 0V-40V/50Hz; 08-30V/60Hz can be customized for all fan coil units. 9

21

22 Cassette Series 4-way Cassette Compact 4-way Cassette -pipe 4-pipe -pipe 4-pipe Various Selections Versions for /4 pipe systems. Versions for compact/normal size. Stylish Panel with Large Airflow Outlet 4-way air supply panel is standard for 4-way cassette. 360 air supply panel is standard for compact 4-way cassette. 4-way panel 360 panel Compact Design, Easy Installation For Compact Four-way Cassette: Extremely compact casing suits any room's decor and requires little space for installation on a low ceiling. Due to compact body and light weight, all models can be installed without a hoist High Efficiency and Low Sound Operation Thanks to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Various Accessories Selections Safe factory-installed electric heater is optional. Extended drainage pan for better ceiling protection is optional. High-lift Drain Pump Standard built-in drain pump with 750 pump head for normal size and 500 for compact size. 750 Fresh Air Intake Fresh air can enter through the cassette unit so you can enjoy even fresher air in a room.

23 -Pipe 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKA-V600R 33/793/ /467/ /4.35/ /5.9/ /33/ MKA-V750R 0-40//50 55/879/68 739/57/ /4.5/ /6./ /37/8 DC motor Centrifugal, forward-curved blades.6 Φ RC3/4 ODΦ3 MKA-V850R 44/009/7 848/594/ /5.33/ /7.5/ /36/ Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKA-V950R 494/046/ /66/ /5.7/ /7.35/ /37/ MKA-V00R 0-40//50 596/7/ /657/ /5.3/ /7.43/ /39/3 DC motor Centrifugal, forward-curved blades.6 Φ RC3/4 ODΦ3 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 3. Noise is tested in a semi-anechoic test room. MKA-V500R 850/95/95 089/76/ /8.09/ /.9/ /40/

24 4-Pipe 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Water flow rate Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h L/h W MPa inch MKA-V600F 87/83/ /489/ /3.77/ /5.4/ /3/5 MKA-V750F 0-40//50 33/863/67 76/508/ /3.94/ /5.64/ /34/6 DC motor Centrifugal, forward-curved Blades.6 Φ Cold water: RC3/4; Hot water: RC/ ODΦ3 MKA-V850F 436/005/78 845/59/43 5.9/4.0/ /5.99/ /34/7 Power supply Air flow (H/M/L) Cooling Water flow rate Heating Water flow rate Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h L/h W MPa inch MKA-V950F 56/068/ /69/ /4.6/ /6.6/ /35/ Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 70 C, temperature drop 0 C DB, entering air temperature 0 C DB. 3. Noise is tested in a semi-anechoic test room. MKA-V00F 0-40//50 768/38/884 04/79/50 9.0/6.85/ /8.59/ /37/3 DC motor Centrifugal, forward-curved Blades 3.6 Φ Cold water: RC3/4; Hot water: RC/ ODΦ3 MKA-V500F 85/33/945 /779/ /7.3/ /9.8/ /39/

25 -Pipe Compact 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch 4-Pipe Compact 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Water flow rate Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h L/h W MPa inch MKD-V /39/80 330/3/65 3.0/.3/ /3/ /9/ MKD-V300F 560/397/84 334/34/67.39/.8/ /.98/ /6/0 MKD-V //50 77/50/359 4/96/ 3.93/3.07/ /4/ /36/8 DC motor Centrifugal, forward-curved Blades.6 Φ G3/4 ODΦ5 MKD-V400F 0-40//50 77/50/359 4/86/.88/.9/ /3.6/ /8/ DC motor Centrifugal, forward-curved Blades.6 Φ Cold water: G3/4; Hot water: G/ ODΦ5 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: pipe: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. Heating conditions: 4 pipe: entering water 70 C, temperature drop 0 C DB, entering air temperature 0 C DB. 3. Noise is tested in a semi-anechoic test room. MKD-V /730/ /430/ /3.6/ /4.76/ /37/30 MKD-V500F 785/550/393 46/34/3 3.4/.46/ /3.75/ /3/5 4

26 Duct Series -Pipe Duct 4-Pipe Duct Various Selections Versions for normal/high temperature different systems., 3 or 4 row coils for -pipe system, and 3 row coils for 4-pipe system. Large range of available static pressure. High Efficiency and Low Sound Operation Due to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Flexible Installation Left and right hand piping connections are optional, flexible installation. Left hand Front discharge Right hand Standard Return Air Plenum and Filter Standard return air plenum and filter guarantees clean air supply and stable air flow rate. Fresh Air Intake Fresh air can enter through the duct unit so you can enjoy even fresher air in the room. 5

27 -Pipe -Row Duct Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT-V00 340/55/70 00/50/00 /.74/ /.75/ /3/5 40/36/9 43/39/ MKT-V300 50/385/55 300/5/ //50 Pa (default), 30/50Pa can be set through dial switch on PCB.7/.3/ /3.74/ /33/6 4/37/30 44/40/3 DC motor Centrifugal, forward-curved Blades.6 Φ RC3/4 R3/4 MKT-V /50/ /300/00 3.6/3./ /4.64/ /34/7 4/38/3 45/4/ MKT-V /640/45 500/375/50 4.4/3.74/ /5.78/ /35/8 43/39/3 46/4/ Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT-V600 00/765/50 600/450/ /4.58/ /6.77/ /36/9 44/40/33 47/43/ MKT-V /00/ /600/ /6.33/ /9.48/ /37/30 45/4/34 48/44/36 DC motor Centrifugal, forward-curved Blades Φ //50 MKT-V /75/ /750/500 Pa (default), 30/50Pa can be set through dial switch on PCB RC3/4 R3/4 8.9/7.6/ /.7/ /39/3 46/4/34 50/45/ MKT-V00 040/530/00 00/900/ /9.3/ /4.05/ /40/33 47/43/34 50/46/ Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at 0Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. 6

28 -Pipe 3-Row Duct Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT3-V00 340/55/70 00/50/00./.9/ /3.08/ /3/6 40/36/9 4/39/ MKT3-V300 50/385/55 300/5/ //50 Pa (default), 30/50Pa can be set through dial switch on PCB 3./.7/ /4.6/ /33/6 4/38/30 43/40/3 DC motor Centrifugal, forward-curved Blades 3.6 Φ RC3/4 R3/4 MKT3-V /50/ /300/00 4/3.4/ /5.85/ /34/7 4/38/3 45/4/ MKT3-V /640/45 500/375/50 4.5/3.96/ /6.95/ /35/8 43/38/3 45/4/ Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT3-V600 00/765/50 600/450/ /4.88/ /8.6/ /36/9 44/40/33 47/43/ MKT3-V /00/ /600/400 8./6.88/ /.97/ /37/30 45/40/34 47/44/36 DC motor Centrifugal, forward-curved Blades Φ //50 MKT3-V /75/ /750/500 Pa (default), 30/50Pa can be set through dial switch on PCB RC3/4 R3/4 9/7.8/ /4.4/ /39/3 46/4/34 50/45/ MKT3-V00 040/530/00 00/900/600 /9.8/ /8.7/ /40/33 47/4/34 50/45/ Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at 0Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. 7

29 -Pipe 4-Row Duct Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT4-V00 340/55/70 00/50/00.5/.6/ /3.5/ /33/7 4/36/30 43/39/ MKT4-V300 50/385/55 300/5/ //50 Pa (default), 30/50Pa can be set through dial switch on PCB 3.3/.85/ /5.05/ /33/6 4/38/30 43/40/3 DC motor Centrifugal, forward-curved Blades 4.6 Φ RC3/4 R3/4 MKT4-V /50/ /300/00 4.4/3.7/ /6./ /35/7 4/38/3 45/4/ MKT4-V /640/45 500/375/50 4.8/4.8/ /7.04/ /35/8 43/38/3 46/4/ Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT4-V600 00/765/50 600/450/300 6./5.38/ /9.03/ /36/9 44/40/33 47/43/ MKT4-V /00/ /600/ /7.43/ /.38/ /37/30 45/40/34 47/44/36 DC motor Centrifugal, forward-curved Blades Φ //50 MKT4-V /75/ /750/500 Pa (default), 30/50Pa can be set through dial switch on PCB RC3/4 R3/4 9.5/8.8/ /3.45/ /39/3 46/4/35 50/45/ MKT4-V00 040/530/00 00/900/600.8/9.8/ /6.7/ /40/33 47/4/35 50/45/ Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at 0Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. 8

30 4-Pipe 3-Row Duct MKT3- Power supply Air flow (H/M/L) Standard external static pressure Cooling Heating Power input Sound pressure level Fan motor Fan Coil Net Dimensions (W H D) Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe V00F V300F V400F V500F V/Ph/Hz 0-40// // // //50 m 3 /h 30/0/40 450/340/80 530/390/60 690/470/370 CFM 90/0/85 70/00/70 30/30/60 40/80/0 Pa.4/./0.8./.7/.5.5/.0/.5 3.0/.4/.9 Water flow rate L/h /.7/.4 3.0/.6/. 3.7/3./.5 4.4/3.6/ W Pa (H/M/L) 35/5/3 36/9/3 38/3/4 43/35/7 30Pa (H/M/L) 4/3/5 39/30/5 44/38/8 46/37/30 50Pa (H/M/L) 43/34/6 44/36/6 47/4/8 48/4/33 Row Max. Working pressure Diameter Pa (default), 30/50Pa can be set through dial switch on PCB. DC Motor DC Motor DC Motor DC Motor Centrifugal, forward-curved Blades MPa Φ9.5 Φ9.5 Φ9.5 Φ inch RC3/4 RC3/4 RC3/4 RC3/4 ODΦ4 ODΦ4 ODΦ4 ODΦ4 MKT3- Power supply Air flow (H/M/L) Standard external static pressure Cooling Heating Power input Sound pressure level Fan motor Fan Coil Net Dimensions (W H D) Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C WB/9 C DB. Heating conditions: entering water 50 C, entering air temperature 0 C, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. V600F V800F V000F V00F V/Ph/Hz 0-40// // // //50 m 3 /h 900/670/440 40/840/670 60/60/ /400/970 CFM 530/400/60 730/500/ /690/ /830/570 Pa 4./3.5/.5 5.3/4./3. 6.7/5.4/3.9 8./6.5/4.6 Water flow rate L/h /4.8/ /5.5/4.6 8./6.9/5. 0./8.6/ W Pa (H/M/L) 46/39/30 46/38/30 48/4/3 47/40/30 30Pa (H/M/L) 49/4/33 49/43/33 49/4/33 50/4/34 50Pa (H/M/L) 5/44/39 5/45/37 5/44/35 53/45/37 Row Max. Working pressure Diameter Pa (default), 30/50Pa can be set through dial switch on PCB. DC Motor DC Motor DC Motor DC Motor Centrifugal, forward-curved Blades MPa Φ9.5 Φ9.5 Φ9.5 Φ inch RC3/4 RC3/4 RC3/4 RC3/4 R3/4 R3/4 R3/4 R3/4 9

31 Wall Mounted C S Stylish Panel Stylish front panel blends easily within any interior décor, ideal for use in shops, restaurants or offices with no or narrow false ceilings. High Efficiency and Low Sound Operation Due to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Convenient Installation Multi-directional outlet pipe feature: left\right\rear, to meet the needs of different rooms. Rear Left Right Built-In 3-Way Electromagnetic Valve Auto Swing Louver The Auto Swing Louver function ensures that the air direction corresponds to the mode selected. Easy Maintenance Removable front panel making maintenance convenient. Step Swing 3 4 Open panel 30

32 Wall Mounted (C ) Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKG-V50 45/40/30 50/4/88./.84/ /.85/ /6/ MKG-V300 50/47/ /5/05.64/.48/ /.9/ /8/ MKG-V //50 680/550/ /34/ /.90/ /3.77/ /3/9 DC motor Tangential fan.6 Φ G3/4 ODΦ0 MKG-V /69/ /407/ /3.78/ /4.4/ /34/ MKG-V600 00/80/ /483/ /3.95/ /5.7/ /36/ Wall Mounted (S ) Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKG-V50B 45/40/30 50/4/88.63/./ /.85/ /6/ MKG-V300B 50/47/ /5/05.97/.48/ /.9/ /8/ MKG-V400B 0-40//50 680/550/ /34/97 3.8/.90/ /3.77/ /3/9 DC motor Tangential fan.6 Φ G3/4 ODΦ0 MKG-V500B 850/69/ /407/ /3.78/ /4.4/ /34/ MKG-V600B 00/80/ /483/ /3.95/ /5.7/ /36/ Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 3. Noise is tested in a semi-anechoic test room. 3

33 Ceiling & Floor Concealed H3 Series Exposed (air return from side) H4 Series Exposed (air return from bottom) H5 Series High Efficiency and Low Sound Operation Due to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Flexible Installation Cabinet and concealed versions meet various installation requirements. Horizontal or vertical installation. Floor installation Ceiling installation Flexible Air Return Air return can be from side or bottom. Movable Louver Removable louver making maintenance convenient. 3

34 Ceiling & Floor Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) H3 (H/M/L) Sound pressure level H4 (H/M/L) H5 (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Body Packing size (W H D) (H3 series) Net weight Body Packing size (W H D) (H4/H5 series) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKH3-V50 MKH4-V50 MKH5-V50 55/5/90 50/5/0.5/0.87/ /.06/ /5/9 30/6/0 9/5/ MKH3-V50 MKH4-V50 MKH5-V50 45/360/30 50/0/90.87/.50/ /.9/ /6/0 3/7/ 30/6/0 DC motor Centrifugal, forward-curved Blades 3.6 Φ //50 G3/4 ODΦ6 MKH3-V300 MKH4-V300 MKH5-V300 50/430/ /50/0.53/.97/ /.63/ /8/ 33/9/3 3/8/ MKH3-V400 MKH4-V400 MKH5-V /580/50 400/340/ /.60/ /3.49/ /30/4 35/3/5 34/30/ Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) H3 (H/M/L) Sound pressure level H4 (H/M/L) H5 (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Body Packing size (W H D) (H3 series) Net weight Body Packing size (W H D) (H4/H5 series) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKH3-V450 MKH4-V450 MKH5-V /650/ /380/ /.88/ /4.03/ /3/6 37/33/7 36/3/ MKH3-V500 MKH4-V500 MKH5-V /70/ /40/ /3.6/ /5./ /33/7 39/34/8 38/33/ MKH3-V600 MKH4-V600 MKH5-V //50 00/870/ /50/ /4.0/ /6.0/ /34/8 4/35/9 40/34/8 DC motor Centrifugal, forward-curved Blades 3.6 Φ G3/4 ODΦ6 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 3. Noise is tested in a semi-anechoic test room. MKH3-V800 MKH4-V800 MKH5-V /60/00 800/680/ /5.9/ /7.58/ /35/9 4/36/30 4/35/ MKH3-V900 MKH4-V900 MKH5-V /300/50 900/760/ /6.08/ /8.7/ /37/3 44/38/3 43/37/

35 Dimensions 4-way cassette -pipe 4-way cassette Dimensions (unit:) Tubing side Drain side 4-Pipe 4-way cassette Dimensions (unit:) Tubing side Drain side 680(Hook-location) 840(Body) 950(Panel) (Hook-location) 840(Body) 950(Panel) B A C D 780(Hook-location) 840(Body) 950(Panel) Size MKA-V600R MKA-V750R MKA-V950R MKA-V00R MAK-V500R A B C D (Hook-location) 840(Body) 950(Panel) Service Spaces (unit:) Drain pipe joint Water pipe joint Drain pipe joint Water pipe joint >000 >000 C 330 >330 >000 >000 Ceiling >500 Outlet Inlet Outlet 880 (ceiling hole) 600 (ceiling hole) Panel Ceiling 4000~500 Outlet Inlet 880 (ceiling hole) Outlet Ground -pipe 4-way cassette Ground 4-pipe 4-way cassette 34

36 Compact 4-way cassette -pipe compact 4-way cassette Dimensions (unit: ) Drain side Tubing side 4 53(Hook-location) 575(Body) 647(Panel) (Hook-location) 575(Body) 647(Panel) 4-pipe compact 4-way cassette Dimensions (unit: ) Drain side Tubing side 53(Hook-location) 575(Body) 647(Panel) (Hook-location) 575(Body) 647(Panel) Service Spaces (unit: ) Water pipe joint Drain pipe joint Water pipe joint Drain pipe joint >000 >000 >300 >300 >000 >000 Ceiling 300~800 Outlet Inlet 600 (ceiling hole) Outlet Panel Ceiling 300~800 Outlet Inlet 600 (ceiling hole) Outlet Panel Ground -pipe compact 4-way cassette 4-pipe compact 4-way cassette 35

37 Height of the front panel H () 4-way cassette 45 H Wall mounted - S type Dimensions (unit: ) Compact 4-way cassette C Size MKG-V50-B MKG-V300-B MKG-V400-B MKG-V500-B MKG-V600-B A B A B D C D Wall mounted - C type Dimensions (unit: ) Size A MKG-V50 MKG-V300 MKG-V MKG-V500 MKG-V C A D B C D Duct Dimensions (unit: ) F A B (Air return) Drain port Terminal box hanger slots C D E pipe duct water inlet Water outlet Air release valve Drain port 40 ZG3/4 Cold water inlet RC3/4 4-pipe duct Hot water outlet RC3/4 Cold water outlet RC3/4 Air release valve 0 Hot water inlet RC3/4 36

38 A A 43 B D C Exposed type A() B() C() D() MKH4-V50/50 MKH5-V50/50 MKH4-V300/400 MKH5-V300/400 MKH4-V450/500 MKH5-V450/500 MKH4-V600~900 MKH5-V600~900 MKH3-V50/ MKH3-V300/ MKH3-V450/ MKH3-V600~ A() B() C() D() A A D B A C MKF3 MKH3 Dimensions (unit: ) Concealed type Ceiling & Floor (continued: duct units dimensions) Size 00CFM 300CFM 400CFM 500CFM 600CFM 800CFM 000CFM 00CFM A B D E F C

39 Control Devices Wireless remote controllers Appearance Function Descriptions Applicable FCUs R05/BGE LCD display screen Mode control Fan speeds control Time setting / Temp. setting / Swing setting 4-way Cassette (standard) Compact 4-way cassette (standard) Wall mounted (standard) Wired controllers Appearance Function Descriptions Applicable FCUs LCD display screen KJRP-86A-E Mode control Fan speeds control Timer setting / Temp. setting Duct without electric heater (optional) Mechanical thermostat KJR-8B/E KJR-B/D Mode control Fan speeds control Temp. setting LCD display screen Mode control / Fan speeds control Electric heater control Temp. setting Duct without electric heater (optional) Duct with electric heater (optional) KJR-5B/E KJR-9B/E KJR-B/E Centralized controllers LCD display screen Mode control Fan speeds control Temperature display in o F or o C LCD display screen Mode control Fan speeds control Temp. setting Swing function Mode control Fan speeds control Temp. setting Floor standing / Ceiling & floor (optional) Cassette / Wall-mounted (optional) Cassette / Wall-mounted (optional) Appearance Function Descriptions Applicable FCUs Large LCD display screen CCM03 Max. of 64 FCUs can be controlled by a CCM03 Mode control / fan speed control Time setting / temp. setting / swing setting CCM09 Weekly schedule function Basic functions are same as CCM03 All FCUs (Compact 4-way cassette FCUs need adding NIM0 module, non-pcb FCUs need adding PC board control kit) CCM30 Touch-style keys Basic functions are same as CCM03 38

40 Accessories PC Board Control Kit for FCU Available for all non-pcb FCUs. Flexible installation, it can be attached to the unit, mounted on a wall or hung under a ceiling. External installation making maintenance more convenient. Functions: Three fan speeds control, Water pump control, Long-distance ON/OFF control, ALARM function, Electric heater control. Operating status can be displayed by wired controller lamp indicator. Centralized control function. BMS control function through Modbus protocol. PC Board Control Kit Centralized control X,Y,E X,Y,E X,Y,E X,Y,E Centralized controller BMS control function through Modbus protocol P,Q,E P,Q,E P,Q,E P,Q,E QE P R+ R- E RS3 Pin hole Modbus Modbus BMS USB port 39

41 Applicable appliance CE-FCUKZ-03 -pipe FCUs CE-FCUKZ-04 4-pipe FCUs Power supply V-Ph-Hz 0~40--50/60 Operation range Room temp. o C 7-30 Temp. controlling precision Net dimension Packing size Inlet water temp. W H D W H D o C o C 3-75 ± Net weight.4.5 Valve Kit Working Voltage: AC30±0%, 50/60Hz(4V can be customized). Power Consumption: 4W Nominal Pressure:.6MPa. Applied Medium: Cold or hot water, 50% glycol water liquor. Medium Temperature: -5 C(DDSTF-0), -0- C(DDSTF-04/05). Environment Temperature: C(DDSTF-0), 0-50 C(DDSTF-04/05). DDSTF-0 DDSTF-04 DDSTF-05 DN() Inner Screw Thead Applicable Appliance DDSTF-0 0 3/4 -pipe cassette/duct/floor standing, 4-pipe duct DDSTF-04 5 / 4-pipe cassette (for hot water) DDSTF /4 -pipe ceiling & floor, 4-pipe cassette (for cold water) 40

42 Application of Central Control & BMS Control PCB Kit PCB Kit PCB Kit M-interface M-net LAN PC Access Laptop Access Pad Access Cloud Servers 4th generation monitoring system PC Data converter CCM5 Internet Router BMS BACnet Modubus LonWorks BMS gateway PC in LAN TCP/IP network Note: if cassette type units connect to centralized controller or BMS, PCB of the unit should be customized. 4

43 Selection Software Features Select by entering air and water conditions as well as fan speed. Easy to operate interface and visual display. Powerful project management function. Main Interface Function Area Management Area Selection Area Add/Delete Unit 4

44 Selection Interface Report Data Interface 43

45 44

46 703-C70 Coercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China Midea CAC After-service Application Midea CAC News Application Postal code: 583 Tel: Fax: cac.midea.com global.midea.com Note: Product specifications change from time to time as product improvements and ios Version Android Version ios Version developments are released and may vary from those in this document.

Evaporadoras Hidrónicas

Evaporadoras Hidrónicas Evaporadoras Hidrónicas Rev. 215-6-4 Rev. 214-9-5 Clima-Flex, S.A. de C.V. Av. Central # 285 Parque Logístico - Delegación La Pila C.P. 78422, San Luis Potosí, México Tel. 52 (444) 161-543 /ClimaFlexMexico

More information

DC Inverter Chillers & DC Fan Coil Units

DC Inverter Chillers & DC Fan Coil Units 70-70 oercial ir onditioners 07/08 D Inverter hillers & D INVERTER oercial ir onditioner Division Midea Group dd.: Midea Headquarters Building, 6 Midea venue, Shunde, Foshan, Guangdong, hina Midea fter-service

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

Fan Coil Unit 50Hz 2012

Fan Coil Unit 50Hz 2012 MCAC-01-16 Unit Hz 01 Coercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: est region of Midea coercial air conditioner department, Industry Avenue, Beijiao, Shunde,

More information

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group 1602-2V1510 Coercial Air Conditioners 2016 VRF 50Hz V+K/V+S/V+R/V+W/V+I/Mini VRF Midea CAC After-service Application Midea CAC News Application Coercial Air Conditioner Division Midea Group Add.: West

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Coercial Air Conditioners 2016 VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

R410A VRF Indoor Unit 50Hz AC Series

R410A VRF Indoor Unit 50Hz AC Series Commercial Air Conditioners 2016 Commercial Air Conditioner Division Midea Group R410A VRF Indoor Unit 50Hz AC Series Midea CAC After-service Application Midea CAC News Application Add.: West Region of

More information

Commercial Air Conditioners Rooftop Package. R410A 50Hz

Commercial Air Conditioners Rooftop Package. R410A 50Hz Commercial Air Conditioners 2016 Rooftop Package R410A 50Hz Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n 1311-R1211 GD Midea Refrigeration Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 D e a l e r i n f o r m a t i o n GD Midea Refrigeration

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15 Midea VRF (V+) V+S (Heat Pump) V+i (Individual) (Heat Pump) V+R (Heat Recovery) MVRF 05/5 Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

Commercial Air Conditioners Split Commercial A/C. R410A 50Hz

Commercial Air Conditioners Split Commercial A/C. R410A 50Hz Coercial Air Conditioners 2016 Split Coercial A/C R410A 50Hz Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content MCAC-ATSM-2014-09 Content 1. Outdoor units lineup... 2 2. Nomenclature... 3 3.Features... 4 4. Description of main components... 8 5. Specifications... 10 6. Dimensions... 14 7. Piping Diagram... 15 8.

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

DESIGN ITALIANO

DESIGN ITALIANO DESIGN ITALIANO 01-06-2017 1 The innovation at your home 35 years of experience An Italian company with 35 years of experience in biomass heating. Since 1981 we have been producing and offering innovative

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data VANJSKE JEDINICE Variable Refrigerant Flow Systems *Preliminary data Index Key Features 0 Outdoor Units 5 Indoor Units 86 Control Systems Central Control Software 8 Accessories Heat Recovery Ventilator

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

VARIABLE REFRIGERANT FLOW SYSTEMS

VARIABLE REFRIGERANT FLOW SYSTEMS VARIABLE REFRIGERANT FLOW SYSTEMS Index VRF System - Outdoor Units 11 Indoor Units: Cassettes 55 Indoor Units: Duct 63 Indoor Units: Wall, Ceiling, Floor 71 Control Systems 85 Heat Recovery Ventilator

More information

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)

More information

Split Commercial A/C. Commercial Air Conditioners S1610. R410A 50Hz. Commercial Air Conditioner Division Midea Group

Split Commercial A/C. Commercial Air Conditioners S1610. R410A 50Hz. Commercial Air Conditioner Division Midea Group 17051S1610 Coercial ir Conditioners 2017 Split Coercial /C R410 50Hz Coercial ir Conditioner Division Midea Group dd.: Midea Headquarters Building, 6 Midea venue, Shunde, Foshan, Guangdong, China Midea

More information

Air-cooled modular Chiller. Nick Technical Engineer

Air-cooled modular Chiller. Nick Technical Engineer Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3

More information

Ultimate VRF System R410A, 50Hz

Ultimate VRF System R410A, 50Hz Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

COMMERCIAL AIR CONDITIONERS. Aqua Mini Chiller 50/60Hz

COMMERCIAL AIR CONDITIONERS. Aqua Mini Chiller 50/60Hz COMMERCIAL AIR CONDITIONERS Aqua Mini Chiller 50/0Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading supplier of commercial

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

DES IGN I T ALI A N O

DES IGN I T ALI A N O DES IGN I T ALI A N O 01-04-2017 1 The innovation at your home 35 years of experience An Italian company with 35 years of experience in biomass heating. Since 1981 we have been producing and offering innovative

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram

More information

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw) MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw) CL25610 to CL25615 English Content 1. Outdoor units lineup... 2 2. Nomenclature... 3 3.Features... 4 4. Description of main components...

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h Product Catalog DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h Table of Contents Product Features Product Benefits Group Controller.....................................................

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1 TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186 HEATING The careful process of selecting system requirements and design is expanding in Italy. Thanks to continuous technological research for this purpose, an exclusive hydronic pump range has found its

More information

2017 LINE UP MINI SPLITS CATALOG

2017 LINE UP MINI SPLITS CATALOG SINGLE ZONE MULTI ZONE LIGHT COMMERCIAL 2017 LINE UP MINI SPLITS CATALOG Residential & Light Commercial Solutions WELCOME SERVICE & SUPPORT We believe that the best way to ensure the complete satisfaction

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST Table of Contents Serving your needs since 1874 1 Product Benefits 3 Product Features 4 Product Functions 6 Product Technologies

More information

Neosys Product catalogue

Neosys Product catalogue 00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016. Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual LCAC/2016.1 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Part 1. General Information... 1 1. Nomenclature...

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Lennox Mini-Split Systems Year-Round Comfort and Performance

Lennox Mini-Split Systems Year-Round Comfort and Performance Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:

More information

Mini unitary chiller. Mini unitary chiller

Mini unitary chiller. Mini unitary chiller Mini unitary chiller Mini unitary chiller Product description Features and benefits Description of main components Specification Operation limits Hydraulic performance Dimension Service space Piping diagram

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

Product Brochure Smart Power. Low Profile Ducted

Product Brochure Smart Power. Low Profile Ducted Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers

More information

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,

More information

A more comfortable, safe and sustainable world

A more comfortable, safe and sustainable world YORK RAC, PAC & VRF 2017 A more comfortable, safe and sustainable world RAC, PAC & VRF Air-conditioning solutions Every market is unique in air-conditioning requirements. In this catalogue our customers

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

42GWC Hydronic Cassette Fan Coil Units

42GWC Hydronic Cassette Fan Coil Units 42GWC Hydronic Cassette Fan Coil Units 42GWC Features It is a compact unit only 298mm in height. The four suspension brackets of the unit adopt the T shape opening, it can be installed up and fixed easily.

More information

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA... FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

technical data Fan coil unit FWB small duct unit

technical data Fan coil unit FWB small duct unit technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary

More information

MVD. Cassette 4 Ways FCU DC Service manual MUCS-W7. CL04417 to CL04419 English.

MVD. Cassette 4 Ways FCU DC Service manual MUCS-W7. CL04417 to CL04419 English. MVD Cassette 4 Ways FCU DC Service manual MUCS-W7 www.mundoclima.com CL04417 to CL04419 English 4-way cassette 1. External Appearance... 2 2. Features... 2 3. Product lineup... 3 4. Accessories... 4 5.

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application 6.2-30 tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application High-performance, energy-saving, cost-effective rooftop air conditioning solutions for your business

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)

More information

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner Welcome Emad Chen Head of Qatar Office Midea Commercial Air Conditioner World AC Market by value in 2017, US$103 billion/ 5% growth rate World Air Conditioning Market from 2014 to 2020(F)in unit terms

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

Chilled Water Precision Air Conditioner for Critical Application

Chilled Water Precision Air Conditioner for Critical Application AIRSYS-P-SC-OPTIMA-HD-E14507V01.3 HD Chilled Water Precision Air Conditioner for Critical Application Cooling Capacity: 42.1kW~180.9kW OPTIMA product family is designed for medium to large data center.

More information

AIR COOLED MINI CHILLER

AIR COOLED MINI CHILLER Catalogue MAC-D-2009(60Hz) AIR COOLED MINI CHILLER MODEL: MAC060D4 MAC090D4 MAC120D4 COOLING CAPACITY: 16.2~33KW For More Than a Century, McQuay has been Devoted to Different Buildings 1010101010101010101010101010101010101010101010101010101010101010101010010101010101010101010101010101010101001010101010101010101010101010101010101010101010101010101010101010101010101010101010101

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

Commercial Air Conditioners 2017/2018

Commercial Air Conditioners 2017/2018 Coercial ir Conditioners 207/208 Water Cooled Screw Chiller Flooded type 340-780kW (R34a) Midea CC Midea CC is a key division of the Midea Group, a leading producer of consumer appliances and provider

More information

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS 2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS Midea Company Profile Established in 1968, Midea Group has grown into a leading consumer appliances and HVAC systems manufacturer. With over 8,000 employees,

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

On the cover Integrated professional services designed for your unique business need.

On the cover Integrated professional services designed for your unique business need. FAN COIL UNITS YGFC On the cover Integrated professional services designed for your unique business need. We care about your business and understand that each business has its unique requirements.our all-encompassing

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

Integrated VarIable refrigerant flow ahu/pau (r410a)

Integrated VarIable refrigerant flow ahu/pau (r410a) Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG. Variable Refrigerant Flow Solutions. TOSOT VRF Catalog 1

HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG. Variable Refrigerant Flow Solutions. TOSOT VRF Catalog 1 HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG Variable Refrigerant Flow Solutions TOSOT VRF Catalog 1 WHY CHOOSE T-VRF IN AMERICA? Local Representation: We decided

More information

Catalogue 2015 AMITIME ELECTRIC CO., LTD Add: Yandong 5th Rd, Dayan Industrial Zone, Huangpu Town, Zhongshan City, Guangdong, China Tel: 86-760-23973810 Fax: 86-760-23973813 Email: info@amitime.com Http://www.amitime.com

More information

2008 Midea Commercial A/C

2008 Midea Commercial A/C 2008 Midea Commercial A/C Controllers Control System 2008 Midea Control System & Selection Software CCM01 Indoor CCM KJR-01B(WD) Rooftop Package Unit Wired Controller MDV Central Control Monitor CCM02

More information

Engineering Data Book

Engineering Data Book 40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information