Split Commercial A/C. Commercial Air Conditioners S1610. R410A 50Hz. Commercial Air Conditioner Division Midea Group

Size: px
Start display at page:

Download "Split Commercial A/C. Commercial Air Conditioners S1610. R410A 50Hz. Commercial Air Conditioner Division Midea Group"

Transcription

1 17051S1610 Coercial ir Conditioners 2017 Split Coercial /C R410 50Hz Coercial ir Conditioner Division Midea Group dd.: Midea Headquarters Building, 6 Midea venue, Shunde, Foshan, Guangdong, China Midea CC fterservice pplication Midea CC News pplication Postal code: Tel: Fax: cac.midea.com global.midea.com Note: Product specifications change from time to time as product improvements and ios Version ndroid Version ios Version developments are released and may vary from those in this document.

2 Midea CC Midea CC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and air conditioning solutions. Midea CC has continued with the tradition of innovation upon which it was founded, and emerged as a global leader in the HVC industry. strong drive for advancement has created a groundbreaking R&D department that has placed Midea CC at the forefront of a competitive field. Through these independent efforts and joint cooperation with other global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide. There are three production bases: Shunde, Chongqing and Hefei. MCC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and HU/FCU. MCC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, ir Cooled Screw/Scroll Chillers, and HU/FCU. MCC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters. Midea Company Introduction Midea CC Introduction 2015 JV with Carrier in China in chiller field, BOSCH in VRF production and Siix in smart control 2014 Launched the duct indoor unit with belt drive fan globally 2010 Built the 3rd manufacturing base in Hefei 2008 Launched the rooftop package ClimaMaster globally 2007 Won the first Midea centrifugal chiller project overseas 2006 Launched the first VSD centrifugal chiller 2004 cquired MGRE entered the chiller industry 2001 Partnered with Copeland to develop the digital scroll VRF system 2000 Developed the first inverter VRF With Toshiba 1999 Entered the CC field

3 Contents 04 Introduction Introduction Introduction 06 General Features Convenient for unit selection Outstanding reliability Easy to installation Flexible choise of accessories Mechanical specification 10 DX HU Series DX HU (ir Handler Unit) Midea split type air conditioners are designed and manufactured to meet the requirements of the home, office, hotel and others public occasion use. The units are completely assembled, internally wired, charged outdoor unit with refrigerant at the factory. DX HU (ir Handler Unit) Series pplication Power supply 220~240V, 1Ph~, 50Hz Series Indoor units (DX HU) Nominal cooling capactity 24k 36k 48k 60k 18 R410 T3 Duct Indoor Unit Floorstanding Indoor Unit 39 s 380~415V, 3Ph~, 50Hz Outdoor units 1. Product s cooling capacity as per specification

4 Introduction Conventional Split /C Series pplication Power Supply Series Medstatic Pressure Duct Nominal 76 k 96 k 120 k 150 k 192 k General Features General Features R410 T1 (Heat Pump) V, 1Ph, 50Hz Indoor Unit Histatic Pressure Duct Convenient for unit selection Floorstanding Wide cooling capacity range V, 3Ph, 50Hz Outdoor Unit Wide cooling capacity range. The duct type split /C is from 76,000 to 192,000. R410 T1 (DC Inverter) (Heat Pump) V, 1Ph, 50Hz V, 3Ph, 50Hz Indoor Unit Outdoor Unit Histatic Pressure Duct Long piping length Max. equivalent piping length is 50m. The outdoor unit can be installed at any ventilation locations. (Unavailable for HU type) Permitted value R410 T3 ( Only) V, 1Ph, 50Hz Indoor unit Medstatic Pressure Duct Histatic Pressure Duct Floorstanding Max. Equivalent piping length Max. height drop between indoor and outdoor unit Outdoor unit up Outdoor unit down 50 m 25 m 30 m Max. equivalent piping length: 50m Max. height drop V, 3Ph, 50Hz Outdoor Unit Medstatic Pressure Duct Outstanding reliability R410 T3 (Heat Pump) V, 1Ph, 50Hz Indoor Unit Histatic Pressure Duct Durable construction Prepainted exterior cabinet panels pass 1000 hours Salt Spray Test for durability. Weatherresistant construction with capped steams and sloped top panels. Floorstanding G90 galvanized heavy gauge plate conforming to STM V, 3Ph, 50Hz Outdoor Unit 1. Product s cooling capacity as per specification

5 nticorrosion treatment as optional Flexible choise of accessories The large split air conditioners with special anticorrosion treatment are suitable for seaside areas or the areas exposed to acidic substances. s General Features Special anticorrosion treatment of heat exchanger provides 5 to 6 times greater resistance against acid rain and salt corrosion. ll PCB parts in the unit are coated with doubleside Wireless remote controller is available for conventional split /C series. can be directly connected with duct & floorstanding indoor unts. General Features moisture proof paint. The outer side of electric box metal cover is spraypainted. ll screws are antirust. Casings of the unit and motors are antirust. R51/CE KJR29B Reliable scroll compressor Centralized control function can be achieved through the centralized controller as optional. MDNIM01 should be connected between the indoor units and centralized controller. (Only available for conventional split /C series) Famous brand compressor: Hitachi, Danfoss, etc. More reliable. No complex internal suction and discharge valves for quieter operation and higher reliability. Compact, lightweight design, and fewer moving parts design. Multiprotection design Max.64 MDNIM01 MDNIM01 MDNIM01 MDNIM01 CCM30 Multimeasurement to ensure units operate normally and reliably: Multiaccessories System current protection, High/low pressure switch protection, Temperature sensor on/off protection, etc. Threephase protector is optional. HP/LP switch Temperature sensor Description Standard T1, Duct Tropical (T3), Duct T1 & Tropical (T3), Floorstanding Optional Standard Optional Standard Optional Easy for installation Filter Units are completely assembled, internally wired, charged outdoor unit with refrigerant at the factory. Outlet drainage The site work only needs to connect refrigerant pipes and counication wires between outdoor unit and indoor unit. EHK (Electric Heater Kits) Liquid pipe Gas pipe Connecting cable Threephase protector Wireless controller Centralized controller 07 08

6 Mechanical specification General Features Casing Unit casing is constructed of heavy gauge galvanized steel plate. Both side of the casing is waterproof and anticorrosion coated. Unit panel structure is allowed to maintain on one side of the unit. Service panels are removed easily and reinstalled by removing bolts. The inside of indoor unit panels will be covered with 10 insulation to prevent heat and noise coming out. Units are available for forklift transportation. Compressor ll units are equipped with directdrive, hermetic, scroll type compressor, and it s builtin motor is cooled with suction gas. The voltage utilization range is ±10% of unit nameplate voltage. The compressors, incorporating a builtin muffler, are mounted on springs within a steel housing to reduce noise. n electric heater around the compressor crankcase to ensure stability starting. DX HU Series DX HU (ir Handler Unit) DX HU Series Heatexchanger coils Innerthreaded copper tubes mechanically bonded to a configured hydrophilic aluminum fin is standard for the outdoor heatexchanger. The one which is equipped in indoor unit is standard configurated with copper tubes. ll the coils are leak tested at 4.4MPa at the factory to ensure the pressure integrity. ll the indoor units are standard configurated a condensate drain pan. Outdoor fan The outdoor fan is multiblade vaneaxial type, made of aluminum alloy for quiet operation and durability. It is directly driven by waterproof motor to ensure reliable continuous operations. Statically and dynamically balanced drive motor design with maintenancefree bearing for outdoor installation. Indoor fan The indoor fan is forwardcurved blade centrifugal fan. Impeller and casing are made of galvanized steel sheet. The high quality ball bearings are airsealed with preset lubricating oil. They are coated after assembly in order to provide corrosion resistance. The fan is directly driven by a waterproof motor. The fan and motor assembly is tested and dynamic balance is implemented in the factory. DX HU Flexible installation Flange of air flow is standard. Dual drainage spouts for versatile installation. Multiple airflow design: Vertical upflow, Vertical downflow, Horizontal leftflow and horizontal rightflow. Outdoor unit KJR23B (Optional) Threephase protector The unit with threephase power supply is equipped with phase sequence protector as optional. These devices protect motors and compressors against problems caused by phase lack, phase imbalance and phase reversal indication. When the voltage is above or below the normal range, it works and prevents unit from suffering voltage fluctuations. ir intake ir delivery Refrigerant pipes Controls Units are completely factorywired with necessary controls and wiring terminals for power wiring. Microprocessor controls the cooling, heating and ventilating modes in response to signals from sensors measuring indoor and outdoor temperatures. It will keep accurate temperature control, minimum drift from the set point and provide better building comfort. Horizontal installation Drainage spouts Washable filter as optional 09 10

7 Specifications Tropical (T3) application, DX HU Indoor unit s T3 application, DX HU Indoor unit Indoor unit model MV24CWN113 MV36CWN113 MV48CWN113 MV60CWN113 Indoor unit power supply (T1/T3) (T1) MOVT24CN113C V, 1Ph~, 50Hz 24,000 / 20, MOVT36CN1(R)13C V, 1Ph~, 50Hz 36,000 / 30, MOVT48CN1R13C V, 1Ph~, 50Hz 48,000 / 40, MOVT60CN1R13C V, 1Ph~, 50Hz 58,000 / 49, High voltage connection 262 Flanges are provided for field installation W DX HU Series SEER (T1) ir flow (Hi) Standard external static pressure (Hi) Max. external static pressure (Hi) (Hi) CFM Pa Pa , ,900 2, Breaker switch (For electric heater only) DX HU Series KJR23B (Optional) KJR23B (Optional) KJR23B (Optional) KJR23B (Optional) H Supply duct dimension (W D) Net (W H D) , , , , / / , , , , / / 85 Vapor line connection copper Liquid line connection copper MV24CWN113 (Unit: ) H W D 1, Tropical (T3) application, DX HU Outdoor unit MOVT24CN113C MOVT36CN113C MOVT36CN1R13C MOVT48CN1R13C MOVT60CN1R13C V, 1Ph~, 50Hz V, 3Ph~, 50Hz (Outdoor unit) W 2,650 3,950 4,050 5,950 6,800 uxiliary drain connection uxiliary drain connection Primary drain connection D MV36CWN113 MV48CWN113 MV60CWN113 1, , , Compressor Refrigerant Type Quantity Type Charged Scroll Scroll 1 1 R410 R Scroll 1 R Scroll 1 R Scroll 1 R T3 application, DX HU Outdoor unit ir flow CFM 1,766 3,000 3,000 3,396 4,031 Fan Type Drive type xial xial xial xial xial Direct Direct Direct Direct Direct W Refrigerant piping size mbient temperature C Φ9.52 / Φ19 Φ9.52 / Φ19 17~52 17~52 Φ9.52 / Φ19 17~52 Φ9.52 / Φ22 17~52 Φ9.52 / Φ22 17~52 L Weight Body (W H D) Net Gross ir inlets Louvered panels H L W (Unit: ) H 1. T1 capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. The standard external static pressure and air flow is based on cooling performance without filter in place. 4. Specifications are subject to change without prior notice for product improvement. Service access MOVT24CN113C MOVT36CN113C MOVT36CN1R13C MOVT48CN1R13C MOVT60CN1R13C

8 Specifications T1 pplication Medium static pressure duct, heat pump Duct Indoor Unit Indoor unit model / Quantity Indoor unit power supply MTB76HWN1 MOV76HN1R / V, 1Ph~, 50Hz 76, MTB76HWN1 MTB120HWN1 MTB120HWN1 MOV120HN1R / V, 1Ph~, 50Hz 120, EER Convenient installation COP 85, , Compact design. Concealed installation without floor space requirement. Hidden in the ceiling, unit installation is not hindered by the location of lighting fixtures or room structure. ir inlet & outlet flange are standard for easy duct connection. Easy maintenance through the inspection port. ir flow (Hi) Standard external static pressure (Hi) W m 3 /h Pa 1, ,250 (2,500CFM) , ,375 (3,750CFM) Free air duct design Multi diffusers from one indoor unit, airconditioned multi rooms at the same time. Three speeds of air supply can be chosen via controller. The indoor unit is suitable for various applications where there are many rooms or halls, such as restaurant, concert halls and hotels. Flexible duct design for different room styles. Fan Type Drive type Net (W H D) Centrifugal Direct 1, , / 106 Centrifugal Direct 1, , / capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. uto Restart Function uto Defrosting Independent Dehumidification Timer PTC Heater nticold ir Function Wired 13 14

9 Specifications T1 pplication High static pressure duct, heat pump MOV76HN1R MOV120HN1R MOV76HN1R MOV120HN1R V, 3Ph~, 50Hz V, 3Ph~, 50Hz 11.7 (Outdoor unit) 17.3 (Outdoor unit) 19.3 (Outdoor unit) 28.6 (Outdoor unit) ir flow rate m 3 /h 12,500 13, Compressor (Type / Quantity) Scroll / 1 Scroll / 1 Refrigerant (Type / Quantity) R410 / 5.4 R410 / 7.5 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ12.7 (Liquid), Φ28.6 (Gas) mbient temperature C 17~46 17~46 C 7~24 7~24 Body (W H D) 1, , ,320 1, ,320 1, / / capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. Indoor unit model / Quantity Indoor unit power supply EER COP ir flow (Hi) Standard external static pressure (Hi) Type Fan Drive type MHB76HWN1 MHB76HWN1 MOV76HN1R / V, 1Ph~, 50Hz 76, , W 1, m 3 /h 4,250 (2,500CFM) Pa Centrifugal Direct MH150HWN1 MH192HWN1 MH150HWN1 MOV150HN1R / V, 1Ph~, 50Hz 150, , , ,500 (5,000CFM) Centrifugal Direct MH192HWN1 MOV192HN1R / V, 1Ph~, 50Hz 192, , , ,800 (6,350CFM) Centrifugal Direct Net (W H D) 1, , , , , , / / / capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement

10 Specifications T1 pplication DC inverter high static pressure duct, heat pump MOV76HN1R MOV150HN1R MOV192HN1R MOV76HN1R MOV150HN1R MOV192HN1R V, 3Ph~, 50Hz V, 3Ph~, 50Hz V, 3Ph~, 50Hz 11.7 (Outdoor unit) 26.9 (Outdoor unit) 32.2 (Outdoor unit) 19.3 (Outdoor unit) 47.9 (Outdoor unit) 53.8 (Outdoor unit) ir flow rate m 3 /h 12,500 16,000 16, Compressor (Type / Quantity) Scroll / 1 Scroll / 3 Scroll / 3 Refrigerant (Type / Quantity) R410 / 5.4 R410 / 10.0 R410 / 11.8 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ16 (Liquid), Φ32 (Gas) Φ16 (Liquid), Φ32 (Gas) mbient temperature C 17~46 17~46 17~46 C 7~24 7~24 7~24 Body (W H D) 1, ,250 1, ,390 1, ,320 1, ,305 1, ,455 1, / / / 336 Model / Quantity Power supply ir flow (H) \ MHC176HWD1N1 MHC96HWD1N1 MHC96HWD1N1()N1 MHC176HWD1N1 MHC96HWD1N1 MHC96HWD1N1() MOVG176HD1N1R / 1 MOVG176HD1N1R / 1 MOU96HD1N1R / V~, 1Ph, 50Hz V~, 1Ph, 50Hz V~, 1Ph, 50Hz EER , , , COP W m 3 /h capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. External static pressure (H) Fan Pa 0 ~ ~ 200 0~ Type \ Centrifugal Centrifugal Centrifugal Drive type \ Direct Direct Direct \ \ Refrigerant pipe Liquid Ф12.7 Ф12.7 Ф9.52 Gas Ф28.6 Ф28.6 Ф25.4 Body (W H D) 1, , , , , , / / / T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement

11 Specifications Tropical (T3) pplication Medium static pressure duct, heat pump Model ir flow MOVG176HD1N1R MOVG96HD1N1R MOU96HD1N1R MOVG176HD1N1R MOVG96HD1N1R MOU96HD1N1R \ V~, 3Ph, 50Hz 8 (Whole unit) V~, 3Ph, 50Hz 9.25 (Whole unit) V~, 3Ph, 50Hz 11.7 (Whole unit) m 3 /h 13,500 13,500 9,800 MT76HRN1 Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) MTB1T96HWN1 MT76HRN1 MOV76HN1C / V, 1Ph~, 50Hz 75,100 / 64, / / 8.85 MTB1T96HWN1 MOVT96HN1R / V, 1Ph~, 50Hz 96,000 / 87, / / MT120HRN1 MT120HRN1 MOV120HN1C / V, 1Ph~, 50Hz 119,400 / 102, / / Compressor Rdfrigerant Fan type Refrigerant pipe mbient temperature Type \ Inverter scroll Inverter scroll Rotary Quantity \ Type \ R410 R410 R410 Quantity \ \ xial fan xial fan xial fan \ Liquid Ф12.7 Ф12.7 Ф9.52 Gas Ф28.6 Ф28.6 Ф25.4 C 15~48 15~48 15~48 C 15~24 15~24 15~24 Body (W H D) 948 1, , ,120 1, ,010 1,705 1,000 1,010 1,705 1,000 1,270 1, / / / T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. EER (T1) , , , COP ir flow (Hi) Standard external static pressure W m 3 /h Pa 11,700 (Whole units) 19.3 (Whole units) 4,250 (2,500CFM) 100 1,400 (IDU) 5.8 (IDU) 5,100 (3,000CFM) ,300 (Whole units) 28.6 (Whole units) 6,375 (3,750CFM) 150 (Hi) Wireless controller Wireless controller Net (W H D) 1, , , , , / / / T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement

12 Specifications Tropical (T3) pplication Medium static pressure duct, cooling only MOV76HN1C MOVT96HN1R MOV120HN1C MOV76HN1C MOVT96HN1R MOV120HN1C V, 3Ph~, 50Hz V, 3Ph~, 50Hz V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 17.3 (Whole units) 19.3 (Whole units) 23.7 (ODU) 28.6 (Whole units) ir flow rate m 3 /h 12,500 12,500 13, Compressor(Type / Quantity) Scroll / 1 Scroll / 1 Scroll / 1 Refrigerant(Type / Quantity) R410 / 5.4 R410 / 6.0 R410 / 7.2 Refrigerant piping size Φ9.52(Liquid), Φ22(Gas) Φ9.52(Liquid), Φ25(Gas) Φ12.7(Liquid), Φ28.6(Gas) mbient temperature Body (W H D) C 17~52 1, ~52 1, ~52 1, C 7~24 1,320 1, ~24 1,320 1, ~24 1,320 1, / / / 217 MT76CRN1 MTB1T96CWN1 MT120CRN1 MT150CRN1 Indoor unit model MT76CRN1 MTB1T96CWN1 MT120CRN1 MT150CRN1 / Quantity MOV76CN1C / 1 MOVT96CN1R / 1 MOV120CN1C / 1 MOV76CN1C / 2 Indoor unit power supply V, 1Ph~, 50Hz V, 1Ph~, 50Hz V, 1Ph~, 50Hz V, 1Ph~, 50Hz 75,100 / 64,100 96,000 / 87, ,400 / 102, ,100 / 130,300 (T1/T3) 22.0 / / / / 38.2 (T1/T3) 7.5 / / / / EER (T1) COP 11.7 (Whole units) 19.3 (Whole units) 1.4 (IDU) 5.8 (IDU) 17.3 (Whole units) 28.6 (Whole units) 21.2 (Whole units) 35.0 (Whole units) ir flow (Hi) Standard external static pressure m 3 /h Pa 4,250 (2,500CFM) 100 5,100 (3,000CFM) 100 6,375 (3,750CFM) 150 7,650 (4,500CFM) 150 (Hi) T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. Wireless controller Wireless controller Wireless controller Net (W H D) 1, , , , , , , , / / / / T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement

13 Specifications Tropical (T3) pplication High static pressure duct, heat pump & cooling only Heat pump: Heat pump: MHB76HRN1 MHB1T96HWN1 MOV76CN1C MOVT96CN1R MOV120CN1C MOV76CN1C MOVT96CN1R MOV120CN1C V, 3Ph~, 50Hz V, 3Ph~, 50Hz V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 17.3 (Whole units) ir flow rate m 3 /h 19.3 (Whole units) 12, (ODU) 12, (Whole units) 13, Compressor (Type / Quantity) Scroll / 1 Scroll / 1 Scroll / 1 Refrigerant (Type / Charged) R410 / 5.4 R410 / 6.0 R410 / 7.2 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ9.52 (Liquid), Φ25 (Gas) Φ12.7 (Liquid), Φ28.6 (Gas) mbient temperature C 17~52 17~52 17~52 only: MHB76CRN1 Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) EER (T1) COP MHB76HRN1 MOV76HN1C / V, 1Ph~, 50Hz 75,100 / 64, / / , (Whole units) only: MHB1T96CWN1 MHB1T96HWN1 MHB76CRN1 MHB1T96CWN1 MOVT96HN1R / 1 MOV76CN1C / 1 MOVT96CN1R / V, 1Ph~, 50Hz V, 1Ph~, 50Hz V, 1Ph~, 50Hz 96,000 / 87, / / ,000 75,100 / 64, / / ,000 / 87, / / (IDU) 11.7 (Whole units) 1.4 (IDU) Body (W H D) 1, ,320 1, , ,320 1, , ,320 1, ir flow (Hi) m 3 /h 19.3 (Whole units) 4,250 (2,500CFM) 5.8 (IDU) 5,100 (3,000CFM) 19.3 (Whole units) 4,250 (2,500CFM) 5.8 (IDU) 5,100 (3,000CFM) 171 / / / 215 Standard external static pressure Pa (Hi) T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. Net (W H D) Wireless controller Wireless controller 1, , , , , , , , / / / / T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement

14 Floorstanding Indoor Unit Heat pump: MOV76HN1C MOVT96HN1R only: MOV76CN1C MOVT96CN1R MOV76HN1C MOVT96HN1R MOV76CN1C MOVT96CN1R V, 3Ph~, 50Hz V, 3Ph~, 50Hz V, 3Ph~, 50Hz V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 11.7 (Whole units) 14.4 (ODU) 19.3 (Whole units) 23.7 (ODU) 19.3 (Whole units) 23.7 (ODU) ir flow rate m 3 /h 12,500 12,500 12,500 12,500 Strong wind, long distance air supply R51/CE R51/E Compressor(Type / Quantity) Scroll / 1 Scroll / 1 Scroll / 1 Scroll / 1 Refrigerant(Type / Quantity) R410 / 5.4 R410 / 6.0 R410 / 5.4 R410 / 6.0 Refrigerant piping size Φ9.52(Liquid), Φ22(Gas) Φ9.52(Liquid), Φ25(Gas) Φ9.52(Liquid), Φ22(Gas) Φ9.52(Liquid), Φ25.4(Gas) mbient temperature C 17~52() / 7~24() 17~52() / 7~24() 17~52() 17~52() Body (W H D) 1, , , , ,320 1, ,320 1, ,320 1, ,320 1, / / / / T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. Touch screen control Washable inlet air filter Screw Screw cap ir intake panel Electrical box, ir filter nticold ir Function uto Restart Function uto Defrosting Independent Dehumidification Timer PTC Heater Features: Standard Optional 25 26

15 Specifications T1 pplication Heat pump Specifications Tropical (T3) pplication Heat pump Indoor unit model / Quantity Indoor unit power supply EER COP W MF276HRN1 MOV76HN1R / V, 1Ph~, 50Hz 76, , Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) EER (T1) COP MF76HRN1 MOV76HN1C / V, 1Ph~, 50Hz 75,100 / 64, / / , (Whole units) MF3T96HRN1 MOVT96HN1R / V, 1Ph~, 50Hz 96,000 / 87, / / , (IDU) (Whole units) 3.0 (IDU) ir flow (Hi) m 3 /h 4,300 (2,530CFM) ir flow (Hi) m 3 /h 4,250 (2,500CFM) 4,800 (2,825CFM) Remote controller Remote controller Remote controller Net (W H D) 1,200 1, ,362 2, Net (W H D) 1,200 1, ,362 2, ,200 1, ,362 2, / / / 154 MOV76HN1R V, 3Ph~, 50Hz ir flow rate m 3 /h 12, Compressor (Type / Quantity) Scroll / 1 Refrigerant (Type / Quantity) R410 / 5.4 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) mbient temperature C 17~46 () / 7~24 () Body (W H D) 1, ,320 1, / capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB; refrigerant pipe length between indoor unit and outdoor 2. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB; refrigerant pipe length between indoor unit and outdoor 3. Specifications are subject to change without prior notice for product improvement. MOV76HN1C MOVT96HN1R V, 3Ph~, 50Hz V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 19.3 (Whole units) 23.7 (ODU) ir flow rate m 3 /h 12,500 12, Compressor (Type / Quantity) Scroll / 1 Scroll / 1 Refrigerant (Type / Quantity) R410 / 5.4 R410 / 6.0 Refrigerant piping size Φ9.52 (Liquid), Φ22 (Gas) Φ9.52 (Liquid), Φ25 (Gas) mbient temperature C 17~52 () / 7~24 () 17~52 () / 7~24 () Body (W H D) 1, , ,320 1, ,320 1, / / T1 cooling capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB. 2. T3 cooling capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB. 3. capacity test condition: Outdoor ambient temperature: 7 C DB / 6 C WB, indoor temperature 20 C DB / 15 C WB. 4. Refrigerant pipe length between indoor unit and outdoor 5. Specifications are subject to change without prior notice for product improvement

16 Specifications s Tropical (T3) pplication only T1 application Duct indoor unit: MTB76HWN1, MTB120HWN1, MHB76HWN1, (Units: ) Indoor unit model / Quantity Indoor unit power supply (T1/T3) (T1/T3) EER (T1) COP MF76CRN1 MOV76CN1C / V, 1Ph~, 50Hz 75,100 / 64, / / (Whole units) 19.3 (Whole units) MF3T96CRN1 MOVT96CN1R / V, 1Ph~, 50Hz 96,000 / 87, / / (IDU) 3.0 (IDU) MFT120CRN1 MOV120CN1C / V, 1Ph~, 50Hz 121,000 / 110, / / (Whole units) 28.6 (Whole units) 1, ,231 T1 application Duct indoor unit: MHC176HWD1N1,MHC96HWD1N1,MHC96HWD1N1() (Units: ) 1, ir flow (Hi) m 3 /h 4,250 (2,500CFM) 58 4,800 (2,825CFM) 56 6,060 (3,560CFM) Net (W H D) Remote controller 1,200 1, ,362 2, Remote controller 1,200 1, ,362 2, Remote controller 1,200 1, ,362 2, , / / / 174 T1 application Duct indoor unit: MH150HWN1, MH192HWN1 (Units: ) 1, MOV76CN1C MOVT96CN1R MOV120CN1C V, 3Ph~, 50Hz V, 3Ph~, 50Hz V, 3Ph~, 50Hz 11.7 (Whole units) 14.4 (ODU) 17.3 (Whole units) 19.3 (Whole units) 23.7 (ODU) 28.6 (Whole units) ir flow rate m 3 /h 12,500 12, , Compressor (Type / Quantity) Refrigerant (Type / Charged) Refrigerant piping size mbient temperature Body (W H D) C Scroll / 1 R410 / 5.4 Scroll / 1 R410 / 6.0 Scroll / 1 R410 / 7.2 Φ9.52 (Liquid), Φ22 (Gas) Φ9.52 (Liquid), Φ25 (Gas) Φ12.7 (Liquid), Φ28.6 (Gas) 17~52 17~52 17~52 1, , , ,320 1, ,320 1, ,320 1, Tropical (T3) application Duct indoor unit: MT76HRN1, MT76CRN1 MHB76HRN1, MHB76CRN1 (Units: ) 1, / / T1 capacity test condition: Outdoor ambient temperature: 35 C, indoor temperature 27 C DB / 19 C WB. 2. T3 capacity test condition: Outdoor ambient temperature: 46 C, indoor temperature 27 C DB / 19 C WB. 3. Refrigerant pipe length between indoor unit and outdoor 4. Specifications are subject to change without prior notice for product improvement. 199 / 215 1,

17 Tropical (T3) application Duct indoor unit: MTB1T96HWN1, MTB1T96CWN1 MHB1T96HWN1, MHB1T96CWN1 (Units: ) T1 & Tropical (T3) application Floorstanding indoor unit: MF276HRN1, MF76HRN1, MF76CRN1, MF3T96HRN1, MF3T96CRN1, MFT120CRN1 (Units: ) 420 1, , ,231 Tropical (T3) application Duct indoor unit: MT120HRN1, MT120CRN1 (Units: ) , , T1 & Tropical (T3) application Outdoor unit: MOV76HN1R, MOV76HN1C, MOV76CN1C (Units: ) 1, , , T1 & Tropical (T3) application Outdoor unit: MOVT96HN1R, MOVT96CN1R (Units: ) 1, ,312 Tropical (T3) application Duct indoor unit: MT150CRN1 (Units: ) , , , T1 & Tropical (T3) application Outdoor unit: MOV120HN1R, MOV120HN1C, MOV120CN1C (Units: ) 1,

18 T1 application Outdoor unit: MOU96HD1N1R (Units: ) 1, ,120 Remote R51 Parameter T1 pplication Outdoor unit: MOVG176HD1N1R, MOVG96HD1N1R (Units: ) s Model: R51/CE ( only type) R51/E (Heat pump type) (): Power: 1.5V (LR03/) 2 1,572 s 970 T1 application Outdoor unit: MOV150HN1R (Units: ) 1,250 Standard features It provides a convenient way for users to control the air conditioners everywhere within a range up to 11m. Builtin daily timer offers the convenience of automatically starting and turning down the air conditioners according to the set time. 948 Wired KJR29B 765 1,250 Parameter 1,615 Model: KJR29B (Touchstyle key) 765 (): Power: From the display panel, extra power is unnecessary. 736 T1 application Outdoor unit: MOV192HN1R (Units: ) Standard features 1,200 Keyboard locking function as standard, it can be used to prevent other people from using the controller. Builtin daily timer offers the convenience of automatically starting and turning down the air conditioners according to the set time. 1,390 1,615 1, Remote signal receiving function 765 KJR29B provides a signal receiver to receive the signal from remote controller. The received signal can be directly sent to the indoor unit by wired controller. It is convenient to control the air conditioner. Remote signal receiver Silent Key

19 Silent mode During the operating, when operate the silent mode, the units can reduce the running noise through setting the fan speed to low automatically. It will help you bring a quieter environment. Centralized CCM30 CCM30 MDNIM01 Centralized control Parameter Model: CCM30 + MDNIM01 (): (CCM30BKEB) (CCM30BKE) (MDNIM01) Power: 198~242V, 50/60Hz (MDCCM30) DC+5V (MDNIM01) s MDCCM30, centralized controller, is a multifunctional device that can control up to 64 indoor units within a maximum connection length of 1200m. User can group control or individual control and the set temperature of each units can also different. The indoor units working status and error codes can be displayed in the screen of CCM30. Via checking the error codes table in the user manual, user can easily find out the malfunction and call the service engineer. Three lock modes Centralized controller provides a superior way to manage the indoor units. Users can be able to make their own choice from three locking mode: locking the wireless controller, locking the running mode or locking centralized controller keyboard as they wish. ccess to network monitoring MDCCM30 is able to bridge up to 64 indoor units to network monitoring system and building management system. s Max.64 MDNIM01 MDNIM01 MDNIM01 MDNIM01 CCM30 Easy installation Two structures design, easy installation. Structure (Model No. CCM30/BKE) should be embedded into the wall and structure B (Model No. CCM30/BKEB) doesn t need. Upper side outlet Rear side outlet Structure Structure B Under side outlet Structure B leadingout mode sketch 35 36

Commercial Air Conditioners Split Commercial A/C. R410A 50Hz

Commercial Air Conditioners Split Commercial A/C. R410A 50Hz Coercial Air Conditioners 2016 Split Coercial A/C R410A 50Hz Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

Commercial Air Conditioners Rooftop Package. R410A 50Hz

Commercial Air Conditioners Rooftop Package. R410A 50Hz Commercial Air Conditioners 2016 Rooftop Package R410A 50Hz Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n 1311-R1211 GD Midea Refrigeration Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 D e a l e r i n f o r m a t i o n GD Midea Refrigeration

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group 1602-2V1510 Coercial Air Conditioners 2016 VRF 50Hz V+K/V+S/V+R/V+W/V+I/Mini VRF Midea CAC After-service Application Midea CAC News Application Coercial Air Conditioner Division Midea Group Add.: West

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Coercial Air Conditioners 2016 VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units Coercial Air Conditioners 07/08 INVERTER DC Inverter Aqua Mini Chillers & Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

R410A VRF Indoor Unit 50Hz AC Series

R410A VRF Indoor Unit 50Hz AC Series Commercial Air Conditioners 2016 Commercial Air Conditioner Division Midea Group R410A VRF Indoor Unit 50Hz AC Series Midea CAC After-service Application Midea CAC News Application Add.: West Region of

More information

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15 Midea VRF (V+) V+S (Heat Pump) V+i (Individual) (Heat Pump) V+R (Heat Recovery) MVRF 05/5 Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit

More information

COMMERCIAL AIR CONDITIONERS

COMMERCIAL AIR CONDITIONERS MCAC09 COMMERCIAL AIR CDITIERS R Tropical Rooftop Package Unit 0Hz ton 0 Coercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea coercial air conditioner

More information

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application 6.2-30 tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application High-performance, energy-saving, cost-effective rooftop air conditioning solutions for your business

More information

Commercial Air Conditioners 2017/2018

Commercial Air Conditioners 2017/2018 Coercial ir Conditioners 207/208 Water Cooled Screw Chiller Flooded type 340-780kW (R34a) Midea CC Midea CC is a key division of the Midea Group, a leading producer of consumer appliances and provider

More information

Lennox Mini-Split Systems Year-Round Comfort and Performance

Lennox Mini-Split Systems Year-Round Comfort and Performance Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA... FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Midea CAC (MCAC) Year

Midea CAC (MCAC) Year 1313-H1210 GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating & Ventilating Equipment Co.,

More information

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1 TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient

More information

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out 50Hz AC, HP and Air Handler Units Up to 70 kw T-Class Commercial Split Systems TSA/TPA and TAA Models Reliable, cost-effective and servicefriendly split systems inside and out Lennox units deliver comfort

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

R410 VRF Indoor Unit 50Hz

R410 VRF Indoor Unit 50Hz COMMERCIL IR CONDITIONERS R410 VRF Indoor Unit 50Hz Coercial ir Conditioner Business Units Midea Group dd: est region of Midea coercial air conditioner department, Industry venue, Beijiao, Shunde, Foshan,

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG: M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out AC, HP and Air Handler Units Up to 20 Tons T-Class Commercial Split Systems TSA/TPA and TAA Models Reliable, cost-effective and servicefriendly split systems inside and out Lennox units deliver comfort

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS 2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS Midea Company Profile Established in 1968, Midea Group has grown into a leading consumer appliances and HVAC systems manufacturer. With over 8,000 employees,

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models T-Class Performance and rugged durability Commercial Split Systems Up to 20-Ton TSA/TPA Models Up to.7 EER Lennox units deliver comfort and control you can depend on Lennox proven design in air conditioners

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Mini unitary chiller. Mini unitary chiller

Mini unitary chiller. Mini unitary chiller Mini unitary chiller Mini unitary chiller Product description Features and benefits Description of main components Specification Operation limits Hydraulic performance Dimension Service space Piping diagram

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. High Efficiency Green Slim Line Ceiling Concealed Ducted Split Systems Cool Only Rev. August 2015 12K - 18K - 24K - 30K - 36K - 42K - 48K - 60K IAQ

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

COMMERCIAL AIR CONDITIONERS. Air Handling Unit & Modular Air Handling Unit

COMMERCIAL AIR CONDITIONERS. Air Handling Unit & Modular Air Handling Unit COMMERCIAL AIR CONDITIONERS Air Handling Unit & Modular Air Handling Unit Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ)

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG: M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating

More information

AHU Plus. DX Air Handling Units

AHU Plus. DX Air Handling Units AHU Plus DX Air Handling Units AHU Plus DX DX Air Handling Units AHUPlusDX-TH: DX Air Hadling Unit with 100% Fresh Air AHUPlusDX -IGK: DX Air Hadling Unit with 100% Fresh Air and Heat Recovery AHUPlusDX-KH:

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology Simply Smart The robust Bosch Inverter Ducted Split air-source heat pump system utilizes just the right amount of energy

More information

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models UP TO.7 EER Lennox units deliver comfort and control that you can depend on The latest offerings from Lennox represent a new design in air conditioners

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)- Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A Contents 1. Product Lineup... 1 2. External Appearance... 1 3. Nomenclature... 1 4. Features... 2 5. List of Functions... 3 6. Specifications... 6 7. Dimensional Drawings... 8 8. Wiring Diagrams... 9 9.

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-0V ~ 0Hz Ph 0-0V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Ducted Split System Heat Pump - - - 0 - - - 0 DC Inverter Inverter Technology $ Operation Hydrophilic Aluminum Fins Independent

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated,

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control... R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information

air systems Roomtop RTC-RTH 15 to 30 - L

air systems Roomtop RTC-RTH 15 to 30 - L air systems Roomtop RTC-RTH 15 to 30 - L york air-conditioning products Roomtop RTC-RTH - L A complete range from 14.6 kw up to 27.0 kw YKN2open Features New YKN2open board Possibility to be installed

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become

More information

Amena s Globo series are a group of air conditioning products designed for markets where maximum

Amena s Globo series are a group of air conditioning products designed for markets where maximum mena s Globo series are a group of air conditioning products designed for markets where maximum ambient temperatures are not more than 43 C. These products are available in both cooling only and heatpump

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

Air Handling Unit & Modular Air Handling Unit

Air Handling Unit & Modular Air Handling Unit 509 ommercial ir onditioners 2016 ommercial ir onditioner Division Midea Group ir Handling Unit & Midea fterservice pplication Midea News pplication dd.: West Region of Midea ommercial ir onditioner Department,

More information