Commercial Products Matrix. SUBJECT TO CHANGE WITHOUT NOTI CE TYPE OF SALE: 6JSS SHIPPING POINT: Lewisburg, TN

Size: px
Start display at page:

Download "Commercial Products Matrix. SUBJECT TO CHANGE WITHOUT NOTI CE TYPE OF SALE: 6JSS SHIPPING POINT: Lewisburg, TN"

Transcription

1 SUBJECT TO CHANGE WITHOUT NOTI CE TYPE OF SALE: 6JSS SHIPPING POINT: Lewisburg, TN PACKAGED ROOFTOP ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5, 10 & 12.5 TONS units are highefficiency, singlepackaged electric cooling units that are prewired and precharged with environmentally sound (R410A) HFC refrigerant. Electric heat is available as a fieldinstalled accessory. The units are factory tested in the cooling mode. Models Certified to ISO 9001:2000 STANDARD FEATURES (R410A) HFC refrigerant ASHRAE compliant 13 SEER efficiency levels Energy Star qualified Singlestage cooling capacity control on all models and the 091,101 and 121 models. Rated in accordance with ARI Standard 210 ( sizes) and 360 ( sizes) Designed in accordance with Underwriters Laboratories Standard 1995 Listed by UL and UL, Canada Singlestage cooling capacity control Exclusive noncorrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain Prepainted exterior panels and primercoated interior panels tested to 500 hours salt spray protection Acutrol refrigerant metering system Fully insulated cabinet Cooling operating range from 25 F up to 115 F using winter start kit, 40 Deg.F Std Access panels with easy grip handles and nostrip screw feature Twoinch disposable return air filters Toolless filter access door Standard belt drive, constant torque motor Advanced terminal board for simple safety circuit troubleshooting and control box arrangement Convertible from vertical to horizontal airflow for slab mounting Provisions for thruthebottom power entry capability Single point electric connections Full perimeter base rail with builtin rigging adapters and fork truck slots Scroll compressors with internal linebreak overload protection Copper tube, aluminum fin coils 24volt control circuit protected with resettable circuit breaker Permanently lubricated evaporatorfan motor Permanently lubricated, totally enclosed condenserfan motors Low pressure, freeze protection, and highpressure switches Liquid line filter drier standard STANDARD WARRANTY 5year electric heater 5year compressor 1year parts Sizes Sizes FACTORY INSTALLED OPTIONS INCLUDE BUT NOT LIMITED TO: Economizer and two position damper options Disconnect and convenience outlet options Multiple optional motor and pulley combinations Corrosion resistant options for evaporator and condenser coils FORM NO. SUPERSEDES PRICE SECTION.1PPC New (3 to 12.5 Tons) For a complete list of options and accessories, refer to the Specification Sheets / Catalog for this unit 1

2 SAP CATALOG ORDERING NOMENCLATURE Position No Example: R A S L 0 A B 0 A A A R = Rooftop A = Electric/Electric,Cooling Only TYPE S = Standard ASHRAE Efficiency EFFICIENCY 036 = 36,000 BTUH = 3 Tons 048 = 48,000 BTUH = 4 Tons 060 = 60,000 BTUH = 5 Tons 072 = 72,000 BTUH = 6 tons 090 = 90,000 BTUH = 7.5 tons ( 2 Compressor) 091 = 90,000 BTUH = 7.5 tons (Single Compressor) 101 = 102,000 BTUH = 8.5 tons (Single Compressor) 120 = 120,000 BTUH = 10 tons ( 2 Compressor) 121 = 120,000 BTUH = 10 tons (Single Compressor) 150 = 150,000 BTUH = 12.5 tons ( 2 Compressor) NOMINAL COOLING CAPACITY H = 208/ K = 208/ L = S = =No Heat SINGLE & 3PHASE R410A ROOFTOP PRODUCT MODEL IDENTIFICATION GUIDE VOLTAGE HEATING CAPACITY (See Spec Sheet for Actual Capacity) A = Standard Motor B = Higher Static Motor MOTOR ( Indoor Fan ) A = None B = Economizer w/bararelief, OA Temp sensor E = Economizer w/bararelief + CO2 Sensor, OA Temp sensor H = Economizer w/bararelief, enthalpy sensor L = Economizer w/bararelief + CO2 Sensor, enthalpy sensor P = 2Position damper w/barorelief OUTDOOR AIR OPTIONS / CONTROL (See Spec Sheet for Details) 0A = No Options 4B = NonFused Disconnect AT = Nonpowered 115v C.O. BR = Supply Air Smoke Detector 7C = NonFused Disconnect + NonPowered 115v C.O. 7K = NonFused Disconnect + NonPowered 115v C.O.+ SA Smoke detector 8A = NonFused Disconnect + SA Smoke detector FACTORY INSTALLED OPTIONS (See Spec Sheet for Details) A = Aluminum / Copper Cond & Evap Coil B = Precoat Alum/CU Cond II Alum / CU Evap C = ECoated Alum/Cu Cond II Alum / CU Evap D = ECoated Alum / Cu Cond & Evap E = Cu / Cu Cond & Alum/Cu Evap F = Copper/Copper Cond & Evap G = Alum / Alum Cond, Alum / Copper Evap Coil A = Standard Packaging B = Less Than Truckload (LTL) Packaging CONDENSER / EVAPORATOR COIL CONFIGURATION (See Spec Sheet for Details) PACKAGING LEGEND SAP Sales Order Process NOTE: The example model number 072L0AB0AAA designates a 6 ton volt electric cooling, accessory electric heating rooftop unit with standard coils and an EconoMi$er IV controlled by OA Temperature. 1. Future availability 2

3 ODS CATALOG ORDERING BASE UNIT MASTER PRICES SINGLE STAGE COOLING MODELS VOLTSPHASE (60 Hz) COOLING CAPACITY (Btuh)* APPROX. SHIP. WT. (Lbs) 036S0AA0AAA , K0AA0AAA 208/ , H0AA0AAA 208/ , L0AA0AAA , S0AA0AAA , K0AA0AAA 208/ , H0AA0AAA 208/ , L0AA0AAA , S0AA0AAA , K0AA0AAA 208/ , H0AA0AAA 208/ , L0AA0AAA , S0AA0AAA , H0AA0AAA 208/ , L0AA0AAA , S0AA0AAA , H0AA0AAA 208/ , L0AA0AAA , S0AA0AAA , H0AA0AAA 208/ , L0AA0AAA , S0AA0AAA , H0AA0AAA 208/ , L0AA0AAA , ORDERING BASE UNIT MASTER PRICES TWOSTAGE COOLING MODELS VOLTAGE/ PHASE/Hz COOLING CAPACITY APPROXIMATE SHIPPING WT. (lbs) 090S0AA0GAA , H0AA0GAA 208/ , L0AA0GAA , S0AA0GAA , H0AA0GAA 208/ , L0AA0GAA , S0AA0GAA , H0AA0GAA 208/ , L0AA0GAA , * Rated in accordance with ARI Standards 210/240, 270 (036121). ALL of the above models comply with the minimum efficiency requirements as defined in the ASHRAE Energy Standard. To determine if compliance with this standard pertains to a given geographical area of the United States, check with local or state municipal building codes or visit the following Internet website: 3

4 POSITION 9 INDOOR MOTOR OPTIONS RTU Model Number example: Ordering Position Number: R A S L 0 A B 0 A A A 9 th DIGIT ORDER CODE A B Standard Static Option High Static Option MASTER PRICE ADDERS VOLTAGE / / / Std. Std. Std. Std. Std. Std. Std. Std. 208/ or Std. Std. Std. Std. Std. Std. Std. Std Std. Std. Std. Std. Std. Std. Std. Std. 208/ NC NC n/a n/a n/a n/a n/a 208/ Cost Cost Cost Cost Cost Cost or Add Add Add Add Add Add Cost Cost Cost Cost Cost Cost Add Add Add Add Add Add POSITION 10 OUTDOOR AIR OPTIONS RTU Model Number example: Ordering Position Number: R A S L 0 A B 0 A A A 1 10 th DIGIT ORDER MASTER PRICE ADDER CODE A None Std. Std. B Temperature Economizer w/ Barometric relief E Temperature Economizer w/ Barometric relief and CO2 1 H Enthalpy Economizer w/ Barometric relief L Enthalpy Economizer w/ Barometric relief and CO2 1 P Motorized 2 pos damper w/ Barometric relief Future availability NOTES: 1. EconoMi$er IV (Vertical airflow only): 100%+ barometric relief capability. Geardriven 3position damper. Includes occupied/unoccupied minimum position and maximum position. Directmount Belimo spring return actuator closes damper on power loss. Dry bulb outdoor air control standard. Enthalpy control available as an accessory. Solidstate control module for nonddc applications OAT and SAT sensors factory installed 4

5 POSITION 11 & 12 FACTORYINSTALLED OPTIONS RTU Model Number example: Ordering Position Number: R A S L 0 A B 0 A A A To determine the Option Ordering Code and place an order: 1. Select the desired combination of options from the table below. The 2letter Ordering Code is listed to the left of the Option combination. 2. Enter the 2letter Code as the 11th and 12th digits of the Base Unit Ordering Number. 3. To determine Master Price for FIOP unit, add price of option combination selected to master price of base unit. FACTORYINSTALLED OPTION S OPTION NOTES 2 NonFused Disconnect Switch 2 5 Unpowered Convenience Outlet 3 9 Supply Air Smoke Detector FACTORYINSTALLED OPTION PRICES ORDER OPTIONS MASTER PRICE ADDER CODE A None Standard Standard 4B 2 7C 2,5 7K 2,5,9 8A 2,9 AT 5 BR 5,9 NOTES: 2. Nonfused disconnect switch cannot be used when rooftop MOCP electrical rating exceeds 80 amps. 3. Unpowered convenience outlet requires separate field supplied v power source. Transformer is NOT included. 5

6 POSITION 13 CORROSION RESISTANT COILS RTU Model Number example: Ordering Position Number: R A S L 0 A B 0 A A A Environment EnviroShield Description Standard NonCorrosive Mild Coastal Moderate Coastal Severe Coastal Industrial Industrial & Coastal Alum Fin / Cu Tube X PreCoated Al / Cu X Cu / Cu X ECoated Al / Cu X X ECoated Cu / Cu X SINGLE STAGE ( 1 Compressor ) COOLING CAPACITY MODELS ( ONLY) 13 th MASTER PRICE ADDERS Digit Condenser Evaporator Order Coil Coil Code (Fins/Tube) (Fins/Tube) A Al/Cu Al/Cu Std. Std. Std. Std. Std. Std. Std. B Pre Al/Cu C ECoated C t d Al/Cu D ECoated Al/C ECoated E Cu/Cu Al/C Al/Cu Al/C F Cu/Cu Cu/Cu TWO STAGE ( Dual Compressor ) COOLING CAPACITY MODELS ( ONLY) 13 th MASTER PRICE ADDERS Digit Condenser Evaporator Order Coil Coil Code (Fins/Tube) (Fins/Tube) G AL/AL AL/CU Std. Std. Std. K ECoat Al / Al AL/CU Notes: 1. Dual stage ( 2 compressor ) models are equipped with a microchannel (MCHX) aluminum / aluminum condenser coil. 2. No MCHX factory coating options are currently available. 6

7 FIELDINSTALLED ACCESSORIES Electric Heaters Unit Size NOM. VPhHz 208/ IFM TYPE STD/MED Electric Heater Part Number CRHEATER101A00 CRHEATER102A00 CRHEATER103B00 CRHEATER104B00 (2) CRHEATER102A00 Nominal Application 3.3/ / / / /11.9 Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet CRSINGLE040A00 CRSINGLE040A / STD/MED/ CRHEATER101A00 CRHEATER102A00 CRHEATER103B00 CRHEATER104B00 CRHEATER105A / / / / STD/MED/ CRHEATER106A00 CRHEATER107A00 CRHEATER108A00 CRHEATER109A / STD/MED CRHEATER101A00 CRHEATER103B00 (2) CRHEATER102A00 (2) CRHEATER103B00 (2) CRHEATER104B / / / / 15.8/19.3 CRSINGLE040A00 CRSINGLE040A00 CRSINGLE040A / STD/MED/ CRHEATER102A00 CRHEATER103B00 CRHEATER105A00 (2) CRHEATER104B / / /19.3 CRSINGLE038A STD/MED/ CRHEATER106A00 CRHEATER108A00 CRHEATER109A00 (2) CRHEATER108A GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 7

8 FIELDINSTALLED ACCESSORIES Electric Heaters (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size NOM. VPhHz 208/ / / IFM TYPE STD/MED STD/MED/ STD/MED/ STD/MED/ STD/MED/ Electric Heater Part Number CRHEATER102A00 CRHEATER103B00 (2) CRHEATER102A00 (2) CRHEATER103B00 (2) CRHEATER104B00 CRHEATER102A00 CRHEATER104B00 CRHEATER105A00 (2) CRHEATER104B00 CRHEATER104B00,105 A00 CRHEATER106A00 CRHEATER108A00 CRHEATER109A00 (2) CRHEATER108A00 CRHEATER108A00,109 A00 CRHEATER102A00 CRHEATER104B00 CRHEATER105A00 (2) CRHEATER104B00 CRHEATER104B00,105 A00 CRHEATER106A00 CRHEATER108A00 CRHEATER109A00 (2) CRHEATER108A00 CRHEATER108A00,109 A00 Nominal Application 4.9/ / / / 15.8/ / / / / / / / / Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet CRSINGLE040A00 CRSINGLE040A00 CRSINGLE040A00 CRSINGLE038A00 CRSINGLE038A00 CRSINGLE037A00 CRSINGLE038A00 CRSINGLE038A00 CRSINGLE037A00 CRSINGLE037A00 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 8

9 FIELDINSTALLED ACCESSORIES Electric Heaters (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 091(Single Stage Cooling) NOM. VPhHz 208/ IFM TYPE STD MED STD/MED/ Electric Heater Part Number CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER114A00 Nominal Applicatio n 18.6/ / / Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet CRSINGLE045A00 1 CRSINGLE045A00 CRSINGLE045A00 CRSINGLE044A STD/MED GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 1 required with Power Exhaust 2 CRSINGLE044A00 required with Power Exhaust 9

10 FIELDINSTALLED ACCESSORIES Electric Heaters (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 090 (Two Stage Cooling) NOM. VPhHz 208/ IFM Type STD MED STD/MED STD/MED Electric Heater Part Number CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER114A00 CRHEATER114A00 Nominal Application 18.6/ / / Single Point Kit Part Number No Convenience Outlet Or Unpowered Convenience Outlet CRSINGLE045A00 1 CRSINGLE045A00 CRSINGLE045A00 CRSINGLE044A00 2 CRSINGLE044A00 2 A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 1 required with Power Exhaust 2 CRSINGLE044A00 required with Power Exhaust 10

11 ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size NOM. VPhHz IFM Type Electric Heater Part Number Nominal Application Single Point Kit Part Number No Convenience Outlet Or Unpowered Convenience Outlet 208/ STD/MED CRHEATER111A00,117A00 CRHEATER111A00,117A / /22.8 ** STD/MED CRHEATER114A00 CRHEATER114A STD/MED/ GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 3 required with Power Exhaust 11

12 ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size NOM. VPhHz IFM TYPE Electric Heater Part Number Nominal Application Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet STD,117A00,110A / / MED,117A00,110A /45.9 ** 121 (Single Stage Cooling) STD MED STD/MED,117A00,110A00,113A00,113A00,113A00,119A00,119A / GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 1 required with Power Exhaust 12

13 ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 120 (Two Stage Cooling) NOM. VPhHz 208/ IFM TYPE STD MED STD MED STD/MED Electric Heater Part Number,117A00,110A00,117A00,110A00,117A00,110A00,113A00,113A00,113A00,119A00,119A00 Nominal Application 37.6/ / / Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet ** 1 1 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 1 required with Power Exhaust 13

14 ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 150 (Two Stage Cooling) NOM. VPhHz 208/ IFM TYPE STD MED STD MED STD Electric Heater Part Number,117A00,110A00,117A00,110A00 STANDARD UNIT,117A00,110A00,113A00,113A00,113A00,119A00 Nominal Application 37.6/ / / Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet MED,119A ,119A GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 1 required with Power Exhaust 14

15 FIELD INSTALLED ACCESSORIES (cont) ELECTRIC HEATERS (See selection on previous pages) REQUIRED HEATER MASTER PRICE ORDER (S) CRHEATER101A00 CRHEATER102A00 CRHEATER103B00 CRHEATER104B00 CRHEATER105A00 CRHEATER106A00 CRHEATER107A00 CRHEATER108A00 CRHEATER109A00 CRHEATER111A00 CRHEATER114A00 SINGLEPOINT KITS (See applications on previous pages) ORDER MASTER PRICE CRSINGLE037A00 CRSINGLE038A00 CRSINGLE040A00 CRSINGLE044A00 CRSINGLE045A00 15

16 FIELD INSTALLED ACCESSORIES ECONOMI$ER IV (CONTROLLER INCLUDED) VERTICAL APPLICATION USAGE APPROX SHIP WT (Lbs) Vertical EconoMi$er IV with solidstate controller, geardriven, DNECOMZR020A02 1 3position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in nonddc applications. Vertical EconoMi$er IV with solidstate controller, geardriven, DNECOMZR021A03 1 3position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in nonddc applications. NOTE: 1 EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. HORIZONTAL APPLICATION USAGE APPROX SHIP WT (Lbs) Horizontal EconoMi$er IV with solidstate controller, geardriven, 3position modulating damper, spring return actuator, DNECOMZR024A02 1 up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in nonddc applications. Horizontal EconoMi$er IV with solidstate controller, geardriven, 3position modulating damper, spring return actuator, DNECOMZR025A02 1 up to 100% barometric relief, supply and outdoor air sensors, and CO2 sensor compatible, for use in nonddc applications. NOTE: 1 EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. 16

17 FIELD INSTALLED ACCESSORIES ECONOMIZER SENSORS ECONOMIZER SENSOR USAGE CHART DESIRED CONTROL METHOD Single Dry Bulb Control ECONOMI$ER IV 1 REQUIRED FIELDINSTALLED SENSOR(S) None. Outside Air dry bulb sensor is factory installed. Differential Dry Bulb Control (1) DNTEMPSN002A00 Single Enthalpy Control (1 AXB078ENT Differential Enthalpy Control (1) AXB078ENT & (1) DNENTDIF004A00 To Add CO 2 DCV Control with above: Duct Mount (1) DNCBDIOX005A00 NOTES: 1. OAT and SAT sensors included for EconoMi$er IV. APPLICATION USAGE DNTEMPSN002A00 Outdoor or Return Dry Bulb Temperature Sensor used with Electro Mechanical control. EconoMi$er IV DNCBDIOX005A00 CO2 Sensor for use in return airstream. Also includes Aspirator Box required for Duct Mounting. EconoMi$er IV AXB078ENT Accusensor II Economizer Differential Enthalpy Control Upgrade EconoMi$er IV DNENTDIF004A00 Return Air Enthalpy Sensor used with ElectroMechanical controls, use with AXB078ENT for differential enthalpy control. EconoMi$er IV 17

18 FIELD INSTALLED ACCESSORIES POWER EXHAUST OPTIONS VERTICAL 1 DNPWREXH030A01 Power Exhaust System (208/230160) DNPWREXH021A01 Power Exhaust System (460360) DNPWREXH022A01 Power Exhaust System (208/230160) DNPWREXH023A01 Power Exhaust System (460360) NOTES: 1 Vertical Power Exhaust requires a vertical Economizer 2 Vertical Power Exhaust package includes exhaust hood, screens, and propeller fan system APPLICATION USAGE / / / DNPWREXH028A01 HORIZONTAL Horizontal Power Exhaust (208/230160) Mounted on Return Ductwork Horizontal Power Exhaust (460360) Mounted on DNPWREXH029A01 Return Ductwork NOTES: 1 Horizontal Power Exhaust should be ductmounted in the return duct 2 Horizontal Power Exhaust package includes exhaust hood, screens, and propeller fan system APPLICATION USAGE All 208/ / All ? FAST # HT01AH859 / V TRANSFORMER Transformer for conversion from 575 volt to 208/230 volt power exhaust applications. APPLICATION USAGE Convert from 575 Volt to Volt Power Exhaust applications. NOTES: 1. Vertical power exhaust package includes exhaust hood, screens and propeller fan system Roof curbs are NOT required with vertical power exhaust. 3. Horizontal power exhaust should be ductmounted in the return ductwork and is supplied with a single fan and wiring harness. 4. Both vertical and horizontal power exhaust packages can be used with either EconoMi$er IV. In either case, the power exhaust is controlled by the EconoMi$er IV controller. 5. Order HT01AH859 / FAST# for 575V applications. 18

19 FIELD INSTALLED ACCESSORIES OUTDOOR AIR DAMPER OPTIONS MANUAL OUTDOOR AIR DAMPERS APPLICATION USAGE DNMANDPR001A03 25% Open Manual Outdoor Air Damper Package CRMANDPR001A02 50% Open Manual Outdoor Air Damper Package DNMANDPR002A03 25% Open Manual Outdoor Air Damper Package CRMANDPR002A02 50% Open Manual Outdoor Air Damper Package EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. MOTORIZED OUTDOOR AIR DAMPERS APPLICATION USAGE CRTWOPOS010A00 Motorized 2position outdoor air damper (25100% Outdoor Air) CRTWOPOS011A00 Motorized 2position outdoor air damper EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. NOTES: 1. Manual dampers include hood assembly, bird screen, adjustable damper blade (to allow up to the rated outdoor air %), and bottom panel with opening. 2. Motorized dampers include bottom panel with opening (100% twoposition damper includes 30% barometric relief capability), and adjustable damper (to allow up to the rated outdoor air %). 3. Motorized dampers will close on loss of power to the rooftop unit. 4. Manual and Motorized dampers are not compatible with a vertical power exhaust module. 19

20 CRRFCURB001A01 CRRFCURB003A01 CRRFCURB002A01 CRRFCURB004A01 FIELD INSTALLED ACCESSORIES ROOF CURB OPTIONS 14inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. 14inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. 24inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. 24inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. APPLICATION USAGE CRBTMPWR001A01 CRBTMPWR002A01 CRBTMPWR003A01 CRBTMPWR004A01 THRUTHEBOTTOM CONNECTION KITS Thruthebottom electrical connections and thruthecurb (not thru the bottom) gas connections. Includes a 3/4inch diameter liquid tight conduit fitting for high voltage power wires and (2) 1/2inch diameter liquid tight conduit fittings for thermostat wires and convenience outlet wires. Includes a 3/4inch inside pipe coupling and gas plate assembly for thruthecurb connections. Provides for watertight seals. Thruthebottom electrical connections and thruthecurb (not thru the bottom) gas connections. Includes a 11/4inch diameter liquid tight conduit fitting for high voltage power wires and (2) 1/2inch diameter liquid tight conduit fittings for thermostat wires and convenience outlet wires. Includes a 3/4inch inside pipe coupling and gas plate assembly for thruthecurb connections. Provides for watertight seals. Thruthe bottom power, control and gas connections. Includes a 3/4inch diameter liquid tight conduit fitting for high voltage power wires, (2) 1/2inch diameter liquid tight conduits for thermostat wires and convenience outlet wires and 1/2inch gas adapter fitting for gas piping. Provides for watertight seal. Thruthe bottom power, control and gas connections. Includes a 11/4inch diameter liquid tight conduit fitting for high voltage power wires, (2) 1/2inch diameter liquid tight conduits for thermostat wires and convenience outlet wires and 3/4inch gas adapter fitting for gas piping. Provides for watertight seal. APPLICATION USAGE NOTE: Access to the bottom of the RTU is required to install a THRUTHEBOTTOM Connection Kit. Recommend installing kit prior to installing RTU on roof curb. CONTROL UPGRADE KITS APPLICATION USAGE DNSTATUS001A00 Fan/Filter Status Switch Indicator light not included Std. Control Time Guard II Automatically prevents the compressor from restarting DNTIMEGD001A00 for at least 4 minutes and 45 seconds after shutdown of the compressor. All Sizes Not required when a corporate programmable thermostat is applied or (1 required) with a PremierLink or RTUMP control. DNPHASE3001A02 Phase Monitor Control Provides phase loss/phase reversal protection All 3Ph & 460v KA99ZT003 / Remote keyed attenuator / test / reset station for use with factory installed smoke detectors. Includes power, alarm & trouble indicator lights. All 20

21 FIELD INSTALLED ACCESSORIES / FAST # AXB035LAA s/a CPLOWAMB001A00 32LT LT LT LT LOW AMBIENT CONTROLS Motormaster II Low Ambient Control Enables cooling system to operate down to 0 F by cycling condenser fan on and off. The control is activated by a temperature sensor. No motor changeout required. Motormaster I SinglePhase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. Motormaster I SinglePhase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. Motormaster I Single Phase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. Motormaster I Single Phase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. HC40GE233 / Motormaster I Compatible Condenser Fan Motor HC40GE463 / Motormaster I Compatible Condenser Fan Motor HC91CL010 / MFD 10 HC93CA013 / Dual MFD HC98JA048 / Dual MFD HC98JA073 / Dual MFD HC98JA083 / Dual MFD NOTES: USED WITH 208/ / All Sizes Refer to Motormaster I Usage Table Refer to Motormaster I Usage Table Refer to Motormaster I Usage Table * FAST List Price Subject to change on a quarterly basis and should be verified with FAST prior to quoting. Sizes require one (1) Low Ambient Controller and one (1) compatible condenser fan motor for changeout. Sizes require one (1) Low Ambient Controller and one (2) compatible condenser fan motor for changeout. / FAST# HD52AK002 / HD52GE577 / CRLOWAMB030A00 CRLOWAMB031A00 CRLOWAMB032A00 LOW AMBIENT CONTROLS (SIZE 150 ONLY) MASTER PRICES Outdoor Fan Motor Required on units with Motormaster V Outdoor Fan Motor Required on units with Motormaster V Motormaster V Low Ambient Kit. Mechanical cooling operation down to 20 F ( 29 C) Motormaster V Low Ambient Kit. Mechanical cooling operation down to 20 F ( 29 C) Motormaster V Low Ambient Kit. Mechanical cooling operation down to 20 F ( 29 C). APPLICATION USAGE 150 Size 208/ Size Size 208/ Size Size * FAST / RCD List Price Subject to change on a quarterly basis and should be verified with FAST / RCD prior to quoting. 21

22 FIELD INSTALLED ACCESSORIES LOW AMBIENT CONTROLS Motormaster I Usage and Parts Table ( Models) MOTORMASTER I UNITS VOLTAGE MOTOR CAPACITOR CONTROLLER Table 5 Single Phase Unit Capacitor Replacement DUAL FAST / RCD UNITS MFD* Part # 208/ HC40GE233 See table 5 32LT K HC98JA / * HC40GE233 Replace with HC91CL010 32LT K HC98JA HC40GE463 Replace with HC91CL010 32LT K HC98JA / HC40GE233 Keep Factory Installed 32LT *Compressor shares capacitor with the OD motor, the first number is for compressors and the second number is for OD motor HC40GE463 Replace with HC91CL010 32LT / (Single ** Compressor Units) (Dual Compressor Units with Microchannel Al/Al condenser coil) * HC40GE / ** (2) HC40GE233 (2) HC40GE463 (2) HC40GE233 (2) HC40GE463 Replace with HC91CL010 Replace with HC93CA013 Replace with HC93CA013 Keep Factory Installed Keep Factory Installed 32LT LT LT LT LT The Capacitor Straps in the unit can be reused. If needed part numbers are as follows: HC91CL005 / FAST# & HC91CL010 / FAST# use HC98ZY071/FAST# , and HC93CA013 / FAST# uses 50DK / FAST# *Transformer HT01AH856 / FAST# (0.75kva, 575v to 230v) and transformer bracket 50DK / FAST# are recommended. **Transformer HT01AH859 / FAST# (1kva, 575v to 230v) and transformer bracket 50DK / FAST# are recommended. 22

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT 50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE RHS Product Specifications ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, 15 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE IEER s up to 11.5 with single speed indoor fan motor and

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

RHX. Product Specifications

RHX. Product Specifications RHX Product Specifications PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE Meets or exceeds ASHRAE 90.1 energy compliant efficiency

More information

Product Data WeatherMaker Single Package Rooftop Heat Pump Units

Product Data WeatherMaker Single Package Rooftop Heat Pump Units Product Data WeatherMaker Single Package Rooftop Heat Pump Units 15 and 20 Nominal Tons Unit shown with economizer and power exhaust. Q 17 and 24 with Puron (R410A) Refrigerant Carrier Corporation 2017

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

ENERGY STAR COMPLIANT 13 SEER SINGLE PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A ROOFTOP 3 5 TONS 575V BUILT TO LAST, EASY TO INSTALL AND SERVICE

ENERGY STAR COMPLIANT 13 SEER SINGLE PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A ROOFTOP 3 5 TONS 575V BUILT TO LAST, EASY TO INSTALL AND SERVICE RGS Product Specifications ENERGY STAR COMPLIANT 13 SEER SINGLE PACKAGE GAS HEATING/ELECTRIC COOLING, R410A ROOFTOP 3 5 TONS 575V BUILT TO LAST, EASY TO INSTALL AND SERVICE Onepiece, high efficiency gas

More information

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES 180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.

More information

Input Cap. (Btuh) Stage 2

Input Cap. (Btuh) Stage 2 Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. RGS Product Specifications

More information

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613 Packaged Heat Pump 14 SEER 3to5NominalTons Product Data C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS & ACCESSORIES... 5 AHRI CAPACITY RATING...

More information

Product Data RELIABILITY FEATURES

Product Data RELIABILITY FEATURES 48TM---P06 Single---Package Rooftop Gas Heating/Electric Cooling Units with PuronR (R---410a) and Microchannel Heat Exchanger (MCH) Limited Production Unit 5Tons Product Data C06101 48TM -P units are single

More information

Input Cap. (Btuh) Stage 2

Input Cap. (Btuh) Stage 2 HIGH EFFICIENCY PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 15 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency gas heating and electric cooling with

More information

ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE RGS Product Specifications ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 7.5 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron 50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron R (R---410A) Refrigerant 15, 17.5, 20, 25, 27.5 Tons --- (Sizes 17, 20, 24, 28, 30) Product Data (Unit shown with economizer and

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Product Data KUWAIT SERIES

Product Data KUWAIT SERIES 50 Hz Packaged Rooftop Electric Cooling Units 18.17 to 30.01 kw 5to8.5Tons Product Data KUWAIT SERIES C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS WeatherExpert R Series Ultra High---Efficiency Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 07 --- 12 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron 50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Product Data. Features/Benefits. 50HJ Single-Package Rooftop High-Efficiency Electric Cooling Units. 3 to 12 1 / 2 Nominal Tons

Product Data. Features/Benefits. 50HJ Single-Package Rooftop High-Efficiency Electric Cooling Units. 3 to 12 1 / 2 Nominal Tons Product Data 50HJ Single-Package Rooftop High-Efficiency Electric Cooling Units 3 to 12 1 / 2 Nominal Tons 50HJ008-014 50HJ004-007 Carrier has designed the Weathermaster series based on customer needs

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29)

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29) 50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29) Product Data (Unit shown with economizer and power

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product

More information

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

Model 579F/580D. Sizes COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS. 3to25Tons. Form No. PDS 580D.36.

Model 579F/580D. Sizes COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS. 3to25Tons. Form No. PDS 580D.36. COMMERCIAL Model 579F/580D SINGLE PACKAGE ROOFTOP Sizes 036-300 GAS HEATING/ELECTRIC COOLING UNITS 3to25Tons 580D036-072 579F180,216 580D090-150 579F240,300 Standard-Efficiency Rooftop Units with: Exclusive

More information

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with economizer and power exhaust.

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with economizer and power exhaust. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons Product Data (Unit shown with economizer and power exhaust.) C12589 the environmentally sound refrigerant PAGE FEATURES AND BENEFITS...

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Advanced Product Data

Advanced Product Data 48PD and 50PD-05, 06 Displacement Ventilation or Single-Zone Variable Airflow Rooftop Units Single Package, Electric Cooling, Gas or Optional Electric Heating with PURON (R-410A) Refrigerant and COMFORTLink

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3 SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS Model 702A 2 to 5 Nominal Tons UNIT 702A Single packaged Cooling Unit for Residential and Light Commercial use. FEATURES/BENEFITS One-piece cooling unit with

More information

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50GL Single-Package Products with Energy-Saving Features and Puron refrigerant. Low Sound

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30 48TC Gas Heat/Electric Cooling Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30 Product Data (Unit shown with economizer and power exhaust.) C12589 the

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

PERFORMANCE, INNOVATION, RELIABILITY

PERFORMANCE, INNOVATION, RELIABILITY WeatherExpert Series Ultra High Efficient Single Package Rooftop and Single Zone VAV Cooling Only with Optional Electric Heat Sizes 04-06 with Puronr (R- 410A) Refrigerant 3-5NominalTon Product Data Unit

More information

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons Product Data 50SX High Efficiency Single-Packaged Cooling Units 2 to 5 Nominal Tons 50SX High Efficiency, Single-Packaged Cooling Unit for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume COMMERCIAL HVAC PACKAGED EQUIPMENT Rooftop Units Level 1: Constant Volume Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application

More information

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons Product Data 50GS Single-Packaged Electric Cooling Units 1-1/2 to 5 Nominal Tons UNIT 50GS Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES 50.TGY (95) SINGLE PACKAGE COOLED CONDITIONERS DCE 0, 0, 00 & DCE 07 0, 0, 00 & 07, AND 5 NOMINAL TONS (0 SEER) AND NOMINAL TONS (9 EER) SHOWN SUNLINE 000 DESCRIPTION YORK Sunline 000 units are convertible

More information

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) 607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data A09033 Fig. 1 - Unit 607C - -A Single-Packaged Products

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Package Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion 38ARZ/ARD Commercial Air-Cooled Split Sizes 007-028 With 40RM007-028 6-25 Nominal Tons - 50Hz Product Data The 38ARZ/ARD condensing units with scroll compressors match Carrier s 40RM indoor-air handlers

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility Landmark Performance Marked by Flexibility Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models Up to 13.0 SEER, 14.0 IEER and 12.7 EER Performance Marked by Flexibility When it comes to reliable

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Model 704B Sizes

Model 704B Sizes SINGLE-PACKAGED ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant Model 704B Sizes 024-060 2 To 5 Nominal Tons UNIT 704B Single-Packaged Products with Energy-Saving Features and Puron refrigerant.

More information

Product Data 50TC. Cooling Only/Electric Heat Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30

Product Data 50TC. Cooling Only/Electric Heat Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30 50TC Cooling Only/Electric Heat Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30 Product Data (Unit shown with economizer and power exhaust.) C12590 the

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. Low

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE RG Product Specifications PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE R-410A HFC refrigerant Meets or exceeds ASHRAE

More information

Advanced Product Data

Advanced Product Data 48LC Ultra High Efficiency Gas Heat/Electric Cooling Packaged Rooftop 3to5NominalTons Advanced Product Data C11536 Exceeds Use of the AHRI Certified TM Mark indicates a manufacturer s participation in

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons Product Data 50LJQ Single-Package Rooftop Heat Pump Units Nominal 3 to 10 Tons Single-Package Rooftop Heat Pump Units with the following Standard Features: 2-in. return-air filters Acutrol refrigerant

More information

Product Data. Features/Benefits. 48TJ Single-Package Rooftop Units Electric Cooling/Gas Heating. 3 to 25 Nominal Tons

Product Data. Features/Benefits. 48TJ Single-Package Rooftop Units Electric Cooling/Gas Heating. 3 to 25 Nominal Tons Product Data 48TJ004-028 Single-Package Rooftop Units Electric Cooling/Gas Heating 3 to 25 Nominal Tons 48TJ008-014 Copyright 1996 Carrier Corporation 48TJ024,028 48TJ004-007 48TJ016,020 Single-Package

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:

More information

48KC Gas Heat/Electric Cooling Single Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613

48KC Gas Heat/Electric Cooling Single Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613 Gas Heat/Electric Cooling Single Packaged Rooftop 14 SEER 3to5NominalTons Product Data C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS AND/OR ACCESSORIES...

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. 13 SEER

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

Model 581B Sizes to12 1 2Tons

Model 581B Sizes to12 1 2Tons COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING UNITS Model 581B Sizes 036-150 3to12 1 2Tons Unit 581B036-072 Unit 581B090-150 Bryant has designed the Tundra series based on customer needs

More information

COMMERCIAL PRODUCTS CONDENSED CATALOG

COMMERCIAL PRODUCTS CONDENSED CATALOG COMMERCIAL PRODUCTS CONDENSED CATALOG International Comfort Products, LLC 650 Heil--Quaker Avenue, Lewisburg, TN 37091 40114220502 Aug. 2008 TABLE OF CONTENTS PAGE 1 -- 5 Model Nomenclature PACKAGE AND

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz Product Data 50TJ016-028 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz Nominal Capacity: 52.8 to 87.9 kw (15 to 25 Tons) Standard Efficiency Rooftop Units with: Dual, electrically

More information

582J GAS HEAT/ELECTRIC COOLING SINGLE PACKAGED ROOFTOP 14 SEER 3 TO 5 NOMINAL TONS. Product Data C (Shown with optional Louvered Hail Guard)

582J GAS HEAT/ELECTRIC COOLING SINGLE PACKAGED ROOFTOP 14 SEER 3 TO 5 NOMINAL TONS. Product Data C (Shown with optional Louvered Hail Guard) GAS HEAT/ELECTRIC COOLING SINGLE PACKAGED ROOFTOP 14 SEER 3 TO 5 NOMINAL TONS Product Data (Shown with optional Louvered Hail Guard) C08515 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

Product Data. 48HJD,HJF HJ Single Package Rooftop Units. 12 to 20 Nominal Tons

Product Data. 48HJD,HJF HJ Single Package Rooftop Units. 12 to 20 Nominal Tons Product Data 48HJD,HJF015-025 50HJ015-025 Single Package Rooftop Units 12 to 20 Nominal Tons 48/50HJ025 48/50HJ015,017 High Performance, Single Package Rooftop Units with: Cooling EERs up to 10.8 Dual,

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. Fig. 1 - Unit 50ES -A

Product Data. Fig. 1 - Unit 50ES -A 50ES---A Comfortt 13 SEER Single---Packaged Air Conditioner tem With Puron (R---410A) Refrigerant Single and Three Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50ES -A A09034

More information

Product Data. Features/Benefits. 48HJD,HJF HJ Single-Package Rooftop Units. 12 to 20 Nominal Tons

Product Data. Features/Benefits. 48HJD,HJF HJ Single-Package Rooftop Units. 12 to 20 Nominal Tons Product Data 48HJD,HJF015-025 50HJ015-025 Single-Package Rooftop Units 12 to 20 Nominal Tons 48/50HJ025 48/50HJ015,017 High Performance, Single Package Rooftop Units with: Cooling EERs up to 10.8 Dual,

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information