Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions

Size: px
Start display at page:

Download "Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions"

Transcription

1 Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions Kipas Elektrik (Kipas Siling) Electric Fan (Ceiling Fan) Nombor Model Model Number F-M15A0 F-M12A0 F-M15B0 Terima Kasih kerana membeli produk Panasonic. Thank you for purchasing Panasonic product. Panasonic Sebelum mengendalikan produk ini, sila baca arahan ini sepenuhnya dan simpan buku panduan ini untuk rujukan masa depan. Before operating this product, please read the instructions carefully, and keep this manual for future reference. Kandungan / Contents / Muka surat / Page / Langkah-Langkah Keselamatan Dan Pencegahan / Safety Precautions / 2 Bahagian-Bahagian Yang Dibekalkan / Supplied Parts / 5 Bagaimana Memasang / How To Install / 5 Pemasangan Pada Sumber Kuasa / Connecting The Power Supply / 10 Penyelenggaraan / Maintenance / 12 Spesifikasi Produk / Product Specification / 12

2 Langkah-Langkah Keselamatan Dan Pencegahan / Safety Precautions / Untuk mengelakkan kemungkinan berlaku kecederaan kepada pengguna atau kerosakan harta benda, sila patuhi semua penerangan yang dinyatakan di bawah. To avoid the possibility of causing injury to users or damage to properties, please follow all the explanations written below. AMARAN WARNING AWAS CAUTION Keadaan yang mungkin disebabkan oleh kecuaian dalam mengendalikan produk, yang mana, jika tidak dielakkan, boleh mengakibatkan kematian atau kecederaan parah kepada pengguna. A state that may be caused by the mishandling of products, which, if not avoided, may lead to the possibility of death or serious injury of users. Penunjuk ini memberi amaran tentang kecederaan atau kerosakan harta benda. This sign warns of injury or damage to property. Simbol ini menunjukkan perbuatan yang WAJIB DILAKUKAN. This symbol denotes an action that is COMPULSORY. Simbol ini menunjukkan perbuatan yang DILARANG. This symbol denotes an action that is PROHIBITED. AMARAN / WARNING / Ikut semua arahan dalam panduan ini untuk pemasangan. Follow strictly to all the instructions given in this manual for installation. Pendawaian elektrik mesti dilakukan oleh orang yang bertauliah. Electrical wiring must be done by competent personnel. Pemasangan mesti dilakukan oleh orang yang bertauliah. Installation must be done by a qualified personnel. Pemasangan yang salah boleh menyebabkan kebakaran, kejutan elektrik, Kipas Siling terjatuh dan kecederaan. Installation error can cause fire, electrical shock, Ceiling Fan drops and injuries. Berhenti mengunakan Kipas Siling apabila berlaku keganjilan atau kegagalan pada operasi Kipas dan padamkan Suis Pemutus Litar Utama ( MCB ) serta-merta. (Risiko terhadap asap, kebakaran, kejutan elektrik dan jatuh) Stop using the Ceiling Fan when any abnormality or failure occurs and turn OFF the Miniature Circuit Breaker (MCB). (Risk of smoke, fire, electric shock and drop) OFF (MCB) 2

3 AMARAN / WARNING / Putuskan bekalan kuasa dan tunggu sehingga Bilah Kipas berhenti sebelum membersihkannya atau menyelenggarakannya. Switch off power supply and wait until the Blade is fully static, before cleaning or doing any maintenance jobs. Boleh menyebabkan Kipas Siling bergerak secara tiba-tiba, kecederaan dan kejutan elektrik. Sila hubungi wakil jualan anda untuk mendapatkan khidmat pembaikan. Can cause Ceiling Fan to move suddenly, injuries and electrical shock. Kindly refer to your sales agent for repairing services. Pastikan Paip diketatkan dengan kukuh pada Shaf Motor. (Daya Kilas mengetat bolt adalah 800~1200N cm) dan Cemat Baji mesti dipasang pada Bolt dan dibengkokkan. Ensure the Pipe has been fully tighten to Motor Shaft. (Bolt tightening torque is 800~1200N cm) and Cotter Pin must fi x into Bolt and bent. 800~1200N cm Jangan buka sebarang bahagian-bahagian Kipas Siling melainkan dinyatakan di dalam panduan ini. Hendaklah menggunakan bahagian-bahagian yang dibekalkan sahaja. Do not dismantle any of Ceiling Fan parts unless stated by this manual. Must use only supplied parts. Boleh menyebabkan kebakaran, kejutan elektrik, Kipas Siling terjatuh dan kecederaan. Can cause fi re, electrical shock, Ceiling Fan drops and injuries. Jangan bergantung pada Kipas Siling. Do not hang up to Ceiling Fan. Jangan sentuh Kipas Siling ketika ia sedang beroperasi. Do not touch the Ceiling Fan while it is operating. Boleh menyebabkan kecederaan, kerosakan dan Kipas Siling Can cause injury, damage and Ceiling Fan drops. Jangan merenjis air atau basahkan Kipas Siling. Do not sprinkle water to the Ceiling Fan or do not wet the Ceiling Fan. Boleh menyebabkan kebakaran, letupan, litar pintas dan kejutan elektrik. Can cause fire, explosion, short circuit and electrical shock. Elakkan pemasangan di tempat yang berminyak. Avoid installing at oily places. Boleh menyebabkan kecederaan jika Kipas Siling Buka Kipas Siling yang patah atau yang mengalami kerosakan. Dismantle the broken or damage Ceiling Fan. Boleh menyebabkan Kipas Siling jatuh dan menyebabkan kecederaan. Can cause Ceiling Fan drops and injuries. Ketatkan Skru Bilah dengan kukuh menggunakan pemutar skru. Tighten the Blade Screws fi rmly using a screwdriver. Boleh menyebabkan kecederaan jika Bilah Kipas Can cause injury if Blade drops. Pastikan Cangkuk Siling boleh menanggung beban 10 kali ganda berat Kipas Siling. Ensure the Ceiling Hook can afford more than 10 times the Ceiling Fan weight. Boleh menyebabkan kecederaan jika Kipas Siling Boleh menyebabkan kecederaan jika Kipas Siling Can cause Ceiling Fan drops and injuries. Jangan gunakan bekalan kuasa selain dari 240V~ 50Hz. Do not use power supply other than 240V~ 50Hz. 240V~ 50Hz Pemanasan yang lampau boleh menyebabkan kejutan elektrik dan kebakaran. Overheating can cause electrical shock and fi re. Elakkan kerosakan wayar semasa pemasangan Kipas Siling dan punca kerosakan daripada suhu yang panas, wayar bengkok dan memintal. Avoid damage wire during Ceiling Fan installation and deformation due to heat, twist and bend. Boleh menyebabkan kebakaran, letupan, litar pintas dan kejutan elektrik. Can cause fi re, explosion, short circuit and electrical shock. 3 Boleh menyebabkan kebakaran, letupan, litar pintas dan kejutan elektrik. Can cause fire, explosion, short circuit and electrical shock. Jangan pasang berhampiran dengan bahan kimia dan alkali. Do not install near chemicals and alkali. Boleh menyebabkan kebakaran, letupan, litar pintas dan kejutan elektrik. Can cause fire, explosion, short circuit and electrical shock. Jangan pasang di kawasan yang berhampiran dengan barang mudah terbakar seperti dapur gas. Do not install near a flammable area such as gas cooker. Mudah menyebabkan kebakaran, letupan, litar pintas dan kejutan elektrik. Can easily cause fire, explosion, short circuit and electrical shock.

4 AWAS / CAUTION / Peralatan ini tidak direka untuk digunakan oleh individu (termasuk kanak-kanak) yang mempunyai kecacatan anggota, deria atau kebolehan mental, atau kurang pengalaman dan pengetahuan, melainkan mereka telah diberikan pemerhatian atau panduan mengenai penggunaan peralatan ini oleh individu yang bertanggungjawab mengenai keselamatan mereka. Kanak-kanak mestilah diberi pemerhatian untuk memastikan mereka tidak bermain dengan peralatan ini. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Untuk mengelakkan kemungkinan berlaku kecederaan pengguna atau kerosakan harta benda, sila patuhi semua arahan yang dinyatakan dalam panduan ini. Pengilang tidak akan bertanggungjawab sekiranya berlaku sebarang kemalangan atau kecederaan yang disebabkan oleh kesilapan pemasangan atau pemasangan yang tidak mengikut buku panduan. To avoid the possibility of causing injury to users or damage to properties, please follow all the instruction written in this manual. The manufacturer will not be responsible for any accidents and injuries caused by defective, deficient installation or installation which does not follow to instruction manual. AWAS / CAUTION / Gantikan kesemua Bilah Kipas jika salah satu daripadanya patah atau retak. Replace all the Blades if any of them broken or crack. Selepas pemasangan, pastikan Kipas Siling tidak terlampau bergoyang. After installation make sure the Ceiling Fan does not wobble extremely. Produk ini adalah untuk kegunaan dalam rumah sahaja. Jangan pasang di tempat yang berangin. This product is for in house use only. Do not install at a windy places. Gegaran boleh menyebabkan Kipas Siling Vibration can cause the Ceiling Fan to fall. Kipas Siling mesti dipasang lebih daripada 2.5m dari lantai dan 1m dari dinding kepada Bilah Kipas. Ceiling Fan must be mounted above 2.5m from the floor and 1m from the wall to the Blade Elakkan daripada memasang pada siling berbentuk kubah. Avoid fi xing inside the dome ceiling. Boleh menyebabkan kecederaan jika Kipas Siling Jangan pasang di tempat yang basah dan berkelembapan tinggi seperti di dalam bilik air. Do not install at a wet and high humidity area such as shower room. Boleh menyebabkan karat, warna luntur, kerosakan dan kecederaan. Can cause rusty, discolour, damage and injury. Lapkan kotoran dengan menggunakan kain yang bersih dan lembut, sabun biasa dan air untuk mengekalkan kebersihan kipas. Jangan gunakan minyak pelincir (gasolin dan petrol) atau bahan kimia lain. Wipe away dirt with a clean soft cloth, ordinary soap and water to keep the fan clean. Do not use solvents (gasoline and petrol) or any other chemicals. Lebih dari 1m / More than 1m / Lebih daripada 2.5m More than 2.5m Boleh menyebabkan kecederaan jika terkena Bilah Kipas. Can cause injury if hit the Blades. Boleh menyebabkan ketidakstabilan aliran angin dan mengakibatkan Kipas Siling bergoyang. Can cause unstable air fl ow and affect the Ceiling Fan to wobble. 2.5 Jika terdapat kebocoran arus elektrik, kejutan elektrik dan kebakaran mudah berlaku. If an electrical current leakage occurs, it can easily cause electrical shock and fire. Elakkan pendedahan angin pada Kipas Siling secara berterusan. Avoid continuous exposure of direct wind from the Ceiling Fan. Ia boleh menyebabkan ketidakselesaan. It may cause discomfort. Boleh menyebabkan kerosakan bahagian plastik dan besi berkarat. Can cause plastic part deformation and metal corrosion. Jangan pasang Kipas Siling di tempat yang mempunyai gegaran dan hentaman yang tinggi. Do not install Ceiling Fan at places where there is high vibration and impact. Boleh menyebabkan kecederaan jika Kipas Siling 4

5 Bahagian-Bahagian Yang Dibekalkan / Supplied Parts / Pemasangan Paip / Pipe Assembly / Cemat Baji / Cotter Pin / Nat / Hexagon Nut / Bahagian-bahagian / Parts / Kuantiti / Piece(s) / 1. Unit Motor / Motor Unit / 1 2. Bilah Kipas / Blade / 3 3. Pemasangan Paip / Pipe Assembly / 1 4. Sengkuap Bawah / Lower Canopy / 1 5. Sengkuap Atas / Upper Canopy / 1 6. Pengawal Kelajuan / Regulator / 1 7. Part Set / Part Set / 1 PERHATIAN / ATTENTION / Jangan letak Kipas Siling di atas lantai. / Do not place the Ceiling Fan directly on the fl oor. / Boleh menyebabkan kesan calar pada produk. / Can cause scratches to the product. / Bagaimana Memasang / How To Install / Sesendal Pegas / Spring Washer / Sesendal Leper / Plain Washer / Bolt Ellipse / Ellipse Bolt / Paip Pilihan / Optional Pipe / Paip pilihan dengan panjang yang berbeza boleh dibeli dari kedai servis Panasonic atau wakil penjual. / Optional Pipe with different length can be purchased from Panasonic service shop or authorized dealer. / Panasonic 1. Paip Pilihan 16"/ 16" Optional Pipe / (16" ) 2. Paip Pilihan 18" / 18" Optional Pipe / (18" ) 3. Paip Pilihan 24" / 24" Optional Pipe / (24" ) 4. Paip Pilihan 30" / 30" Optional Pipe / (30" ) 5. Paip Pilihan 36" / 36" Optional Pipe / (36" ) 6. Paip Pilihan 42" / 42" Optional Pipe / (42" ) 7. Paip Pilihan 48" / 48" Optional Pipe / (48" ) 8. Paip Pilihan 54" / 54" Optional Pipe / (54" ) 9. Paip Pilihan 60" / 60" Optional Pipe / (60" ) A) Pasangkan Pemasangan Paip Pada Motor Unit / Install Pipe Assembly To Motor Unit / 1 Sebelum menyambung Pemasangan Paip pada Unit Motor, keluarkan a) Bolt Ellipse, b) Sesendal Leper, c) Sesendal Pegas, d) Nat dan e) Cemat Baji yang dibekalkan seperti yang ditunjukkan. Before installing the Pipe Assembly to the Motor Unit, remove the supplied a) Ellipse Bolt, b) Plain Washer, c) Spring Washer, d) Hexagon Nut and e) Cotter Pin from Pipe Assembly as shown. c) Masukkan Pemasangan Paip kepada Aci Motor. Pastikan Tuil Suis menekan Suis Keselamatan. Insert Pipe Assembly to Motor Shaft. Ensure Switch Lever press the Safety Switch. a AMARAN / WARNING / Masukkan Pemasangan Paip dengan betul. Kipas tidak akan berfungsi jika Suis tidak ditekan oleh Tuil Suis. Insert Pipe Assemble correctly. This product would not operate if the Safety Switch has not been pressed by Switch Lever. b c d e Aci Motor / Motor Shaft / AMARAN / WARNING / Jangan gunakan Paip yang diubahsuai. Boleh menyebabkan Kipas Siling jatuh dan menyebabkan kecederaan. Do not use modified Pipe. Can cause Ceiling Fan drops and injuries. Pemasangan Paip / Pipe Assembly / Tuil Suis / Switch Lever / Suis Keselamatan / Safety Switch / Lubang Paip dan Shaf Motor adalah selari. Pipe and Motor Shaft hole are aligned. Suis keselamatan ditekan dengan Tuil Suis. Safety switch is pressed by Switch Lever. Jangan tekan Suis Keselamatan menggunakan objek lain selain dari Pemasangan Paip yang diberi. Boleh menyebabkan kebakaran, litar pintas dan kejutan elektrik. Do not press Safety Switch with other object except using the Pipe Assembly given. Can cause fire, short circuit and electrical shock. AMARAN / WARNING / Jangan melencong dan memintas Suis Keselamatan. Boleh menyebabkan kebakaran, kejutan elektrik, Kipas Siling terjatuh dan kecederaan. Do not bypass and short circuit the Safety Switch. Can cause fire, electrical shock, Ceiling Fan drops and injuries. 5

6 2 Pasangkan Pemasangan Paip pada Unit Motor dengan Bolt Ellipse, Sesendal Leper, Sesendal Pegas, Nat dan Cemat Baji. Akhir sekali bengkokkan Cemat Baji selepas pemasangan. Fix the Pipe Assembly and Motor Unit with Ellipse Bolt, Plain Washer, Spring Washer, Hexagon Nut and Cotter Pin. Finally bend the Cotter Pin after assembly. AWAS / CAUTION / Bolt Ellipse / Ellipse Bolt / Sesendal Leper / Sesendal Pegas / Plain Washer / Spring Washer / Cemat Baji / Cotter Pin / Nat / Hexagon Nut / Pastikan Paip dipasang dengan ketat pada Shaf Motor. (Daya Kilas mengetat bolt adalah 800 ~ 1200 N cm). Boleh menyebabkan kecederaan jika Ensure Pipe has been fully tighten to Motor Shaft. (Bolt tightening torque is 800~1200 N cm). Can cause injury if ceiling fan drops. 800~1200N cm Cemat Baji mesti dipasangkan pada Bolt dan dibengkokkan. Boleh menyebabkan kecederaan jika Kipas Siling Cotter Pin must fix into Bolt and bent. Bengkokkan Cemat Baji Bend the Cotter Pin Cemat Baji (bengkok) / Cotter Pin (bend) / <Pandangan Tepi> / <Side View> / <Pandangan Hadapan> / <Front View> / 3 Keluarkan Skru Wayar Keselamatan daripada Aci Motor. Pasang Wayar Keselamatan dengan tepat pada Aci dan Skru Wayar Keselamatan. Remove Safety Wire Screw from Motor Shaft. Fix the Safety Wire fi rmly to the Shaft with Safety Wire Screw. Aci Motor / Motor Shaft / Skru Wayar Keselamatan (dengan sesendal) / Safety Wire Screw (with washer) / Posisi tidak betul / Wrong position / AMARAN / WARNING / Wayar Keselamatan mesti dipasang dengan betul. Boleh menyebabkan kecederaan jika Kipas Siling Safety Wire must be fixed correctly. Pastikan Wayar Keselamatan tidak menyentuh permukaan Motor. Ensure the Safety Wire does not touch the Motor surface. Wayar Keselamatan mesti sentiasa dipasang. Boleh menyebabkan kecederaan jika Kipas Siling Safety Wire must be connected at all times. 4 Sambungkan Wayar Paip pada Terminal 2 Pin. Connect the Pipe Wire to the 2 Pin Terminal. 2 AWAS / CAUTION / Neutral (Biru) / Neutral (Blue) / Pastikan semua pendawaian dilakukan dengan betul oleh orang yang bertauliah bagi mengelakkan kejutan elektrik. Boleh mangakibatkan kebakaran dan kejutan elektrik. Make sure all the Terminals are connected correctly by qualifi ed personnel to avoid electrical hazards. Can cause fi re and electric shock. Hitam / Black / Hidup (Coklat) / Live (Brown) / Hidup (Coklat) / Live (Brown) / Terminal 2 pin / 2 Pin Terminal / 2 6

7 Pemeriksaan Selepas Pemasangan / Check Point After Installation / 1. Pastikan Tuil Suis menekan Suis Keselamatan. / Make sure Switch Lever press the Safety Switch. / 2. Pastikan Bolt Ellipse, Sesendal Leper, Sesendal Pegas dan Nat diketatkan dengan betul dan Cemat Baji dimasukkan ke dalam Bolt dan dibengkokkan bagi tujuan keselamatan. / Make sure the Ellipse Bolt, Plain Washer, Spring Washer and Hexagon Nut are fi rmly tightened and the Cotter Pin is inserted and bent for safety purposes. / 3. Pastikan Wayar Keselamatan diketatkan dengan betul. / Make sure the Safety Wire is fi rmly tightened. / 4. Pastikan semua pendawaian disambung dengan betul oleh orang yang bertauliah. / Make sure all wires are connected correctly by competent personnel. / Neutral (Biru) / Neutral (Blue) / Hidup (Coklat) / Live (Brown) / Tandakan / Check / B) Memasang Bilah Kipas Pada Unit Motor / Install Blade To Motor Unit / 1 Tanggalkan Skru Bilah (6 keping, berwarna perak) dari Pemasangan Motor. Langkah 1 : Pasangkan Bilah ke arah Cangkuk Penutup seperti yang ditunjukkan dalam rajah langkah 1. Langkah 2 : Ketatkan Bilah dengan kuat dengan Skru (Berwarna perak). Setiap Bilah menggunakan 2 batang Skru. (Kilas pengetatan untuk rujukan: N cm). Untuk model F-M15B0, jajarkan Wayar Keselamatan dengan lubang skru Bilah kemudian ketatkannya dengan Skru Bilah. Remove Blade Screw (6 pieces, silver colour) from Motor Assembly. Step 1 : Assemble Blade towards to the Cover Hook as shown in fi gure step 1. Step 2 : Tighten the Blades fi rmly with Screws (Silver colour).each Blade use 2 pieces of Screws. (Tightening torque for reference : N cm) For model F-M15B0, align the Safety Wire with Blade screw hole then tighten it with Blade Screw N cm F-M15B0 Langkah 1 / Step 1 / 1 Untuk model F-M15A0 & F-M12A0 sahaja / For F-M15A0 model & F-M12A0 only / F-M15A0 & F-M12A0 Langkah 2 / Step 2 / 2 ATAU / OR / Untuk model F-M15B0 sahaja / For F-M15B0 model only / F-M15B0 Skru Bilah (6 keping) / Blade Screw (6 pieces) / Lubang Bilah / Blade Hole / Penyangkut Keselamatan Bilah / Blade Safety Hanger / Cangkuk Penutup / Cover Hook / Jajarkan wayar keselamatan dengan lubang skru bilah / Safety wire align with blade screw hole / Pita Wayar Keselamatan / Safety Wire Tape / Lubang Skru Bilah / Blade Screw Hole / Dawai Keselamatan / Safety Wire / Ketatkan Wayar Keselamatan dengan Skru Bilah. / Tighten Safety Wire with Blade Screw / Pastikan Pita Wayar Keselamatan dilekatkan bersama wayar Keselamatan. / Ensure Safety Wire Tape is sticked with Safety wire. / AWAS / CAUTION / Bilah mestilah dipasang dengan betul. Boleh menyebabkan tiada aliran udara. Boleh menyebabkan kecederaan jika bilah Blade must be fixed correctly. Can cause no air flow. Can cause injury if blades drop. Ketatkan Skru Bilah dengan kuat menggunakan pemutar skru. Untuk model F-M15B0, Jangan tanggalkan Wayar Keselamatan. Pastikan Wayar Keselamatan diketatkan bersama dengan Skru Bilah. Boleh menyebabkan kecederaan jika Bilah Boleh menyebabkan bunyi yang tidak normal jika dawai keselamatan tidak diketatkan. Tighten the Blade Screws firmly using a screwdriver. For model F-M15B0, Do not dismantle Safety Wire. Ensure Safety Wire is tighten together with Blade Screw. Can cause injury if Blade drops. Can cause abnormal noise if Safety Wire is not tighten. F-M15B0 Untuk model F-M15A0 dan F-M12A0, jangan tanggalkan Penyangkut Keselamatan Bilah daripada Bilah. Boleh menyebabkan kecederaan jika Bilah For model F-M15A0 & F-M12A0, do not remove Blade Safety Hanger from Blade. Can cause injury if Blade drops. F-M15A0 F-M12A0 7

8 Pemeriksaan Selepas Pemasangan / Check Point After Installation / Tandakan / Check / 1. Skru Bilah (6 batang) untuk mengikat Pemasangan Bilah diskrukan dengan ketat. / The Blade Screws (6 pieces) for securing the Blade Assembly are tightly screwed. / 6 2. Untuk Model F-M15B0, Wayar Keselamatan mesti diketatkan bersama dengan Skru Bilah. / For Model F-M15B0, Safety Wire must tighten together with Blade Screw. / F-M15B0 3. Untuk Model F-M15A0 dan F-M12A0, Penyangkut Keselamatan Bilah mesti dipasang pada kedudukan Bilah. / For Model F-M15A0 & F-M12A0, Blade Safety Hanger must fix at the position on Blade. / F-M15A0 F-M12A0 Model F-M15B0 / Model F-M15B0 / F-M15B0 Model F-M15A0 & F-M12A0 / Model F-M15A0 & F-M12A0 / F-M15A0& F-M12A0 C) Memasang Sengkuap / Install Canopy / 1 Tanggalkan Skru Dawai Keselamatan dan tanggalkan Skru Sengkuap Bawah pada Pemasangan Paip. Simpan Skru Sengkuap Bawah untuk pemasangan di langkah 2. Simpan skru dawai Keselamatan untuk pemasangan di Bahagian D langkah 4. Remove Safety Wire Screw and remove Lower Canopy Screw at Pipe Assembly. Keep the Lower Canopy Screw for installation at step 2. Keep the Safety wire screw for installation at Section D step 4. 2 D4 Paip / Pipe / Skru Wayar Keselamatan (dengan sesendal) / Safety Wire Screw (with washer) / Skru Sengkuap Bawah / Lower Canopy Screw 2 Tarik turun Sengkuap Bawah sehingga ia terhenti dan pasang pada Paip dengan kuat dengan menskrukannya seperti yang ditunjukkan. Pull down Lower Canopy until it stop and fi x to Pipe fi rmly by screwing them as shown. 3 Masukkan Sengkuap Atas pada paip dan tarik ke bawah sehingga ia terhenti di bahagian atas Sengkuap Bawah. Jangan ketatkan Sengkuap Atas dengan skru pada peringkat ini. Insert the Upper Canopy to the pipe and pull it down until it stop at the top of Lower Canopy. Do not tighten the Upper Canopy with screw at this stage. Pemeriksaan Selepas Pemasangan / Check Point After Installation / 1. Masukkan Sengkuap Atas ke dalam Pemasangan Paip. Jangan ketatkan skru! Insert the Upper Canopy to Pipe Assembly. Do not tight the screw! 2. Sengkuap Bawah dipasang Skru dengan selamat. The Lower Canopy is securely Screwed. Tandakan / Check / 8

9 D) Pemasangan Pada Siling dan Pendawaian / Installation to Ceiling and Wiring / 1 Keluarkan Cangkuk-C dari Part Set dan sangkutkan pada Cangkuk Siling. Take out the C-Hook assembly from the Part Set and hook to the Ceiling Hook. C Cangkuk-C / C-Hook / C 2 Ambil Set Kipas Siling dan sangkutkan Paip pada Cangkuk-C yang disangkut pada Cangkuk Siling. Laraskan Cangkuk-C selari dengan lubang Pemasangan Paip dan sangkutkan Cangkuk-C pada Paip Kipas Siling. Take the Ceiling Fan Set and hook the Pipe to the C-Hook which was hooked to the Ceiling Hook. Align the C-Hook parallel with the Pipe s hole and slot the Ceiling Fan Pipe to the C-Hook. CC C Laraskan Cangkuk / Align The Hook / AWAS / CAUTION / Pastikan cangkuk siling boleh menahan beban 10 kali ganda lebih berat daripada Kipas Siling. Ensure the ceiling hook is able to support more than 10 times the Ceiling Fan Weight. 10 Genggam wayar-wayar seperti yang ditunjukkan / Hold the wires as shown / Pastikan Kipas Siling tidak disengetkan supaya Bilah Kipas tidak terkena pada siling ketika pemasangan. Ensure Ceiling Fan is not tilted so that the Blade does not touch the ceiling during installation. 3 Susun dan ikat Wayar Keselamatan seperti yang ditunjukkan. Arrange and tie the Safety Wire as shown. 4 Pasangkan Wayar Keselamatan dengan menggunakan Skru Wayar Keselamatan yang ditanggalkan dari Pemasangan Paip di langkah (1), [Bahagian (C)]. Firmly screw the Safety Wire onto the Pipe Assembly by using the Safety Wire Screw which removed from Pipe Assembly at step (1), [Section (C)]. (1)(C) AWAS / CAUTION / Wayar Keselamatan mesti dipasang dengan betul. Boleh menyebabkan kecederaan jika Kipas Siling jatuh. Safety Wire must fi x correctly. Pemeriksaan Selepas Pemasangan / Check Point After Installation / Tandakan / Check / Cangkuk / Hook / Wayar Keselamatan / Safety Wire / Skru Wayar Keselamatan / Safety Wire Screw / Pemasangan Paip / Pipe Assembly / 1. Pastikan Kipas Siling dipasang dalam keadaan selamat pada Cangkuk Siling. Ensure the Ceiling Fan is securely fi xed on to the Ceiling Hook. 2. Pastikan Wayar Keselamatan ditetapkan dengan selamat pada Cangkuk Siling dan diskrukan pada Pemasangan Paip. The Safety Wire is securely fi xed onto the Ceiling Hook and screwed to the Pipe. 9

10 E) Panduan Pendawaian / Wiring Instruction / Litar pendawaian / Wiring diagram / Sambungkan wayar kepada bekalan rumah seperti gambar rajah. Connect the wires to the house s supply line according to diagram as shown. Sila gunakan splice jika membuat pemasangan pada terminal (tidak dibekalkan). Please use splice when using terminal (not supplied) for installation. LITAR PENDAWAIAN / WIRING DIAGRAM / RED RED BLACK MOTOR BLACK THERMAL FUSE WHITE SWITCH ASSY BROWN Neutral (Biru) / Neutral (Blue) / Siling / Ceiling / Terminal / Terminal / Neutral (Biru) / Neutral (Blue) / Dari Motor / From Motor / Bumi (Hijau/Kuning) / Earth (Green/Yellow) / Hidup (Coklat) / Live (Brown) / Bumi (Hijau/Kuning) / Earth (Green/Yellow) / Hidup (Coklat) / Live (Brown) / BLUE (N) BROWN (L) GREEN/YELLOW(E) AWAS / CAUTION / BROWN SWITCH YELLOW BLUE L TERMINAL BROWN WHITE RED BLACK Pastikan semua Terminal telah dipasang dengan betul oleh orang yang berkelayakan. Electrical wiring must be done by qualified personnel. Boleh menyebabkan kebakaran, kejutan elektrik, Kipas Siling terjatuh dan cedera. Can cause fire, electrical shock, Ceiling Fan drops and injuries. CONDENSER Pemasangan Pada Sumber Kuasa / Connecting The Power Supply / Suis lontaran tunggal dwikutub (Suis Pemutus) / Double pole single throw switch (Switch Breaker) / ~ 240V~ 50Hz Bekalan Kuasa / 240V~ 50Hz Power Supply / 240V~50Hz Bumi / Earth / Kipas Siling / Ceiling Fan / Pengawal Kelajuan / Suis Dinding (Hidup / Padam) / Regulator / Wall Switch (On / Off) / Produk ini tidak dilengkapi dengan wayar dan palam atau apa-apa yang boleh memutuskan sambungan dengan bekalan kuasa. Untuk mengelakkan sebarang kecederaan, pemasangan wayar dan palam mesti dilakukan oleh juruteknik bertauliah. Gunakan 227IEC53(RVV) atau tiub yang berketebalan lebih dari 1mm. (Keperluan lain seperti diameter wayar, hendaklah dipatuhi mengikut peraturan negara-negara berkenaan). This product is not provided with cord and plug or with other means for disconnection from the supply. When connect or change the power cord or lead wire, it must be replaced by the qualifi ed personnel in order to avoid a hazard. Please use 227IEC53(RVV) or thickness of tube is 1mm or above. (Other requirements such as diameter of lead wire, please use according to the regulation of the country). 227IEC53(RVV) Pemeriksaan Selepas Pemasangan / Check Point After Installation / 240V~ 50Hz 1. Pendawaian mesti disambung dengan betul pada bekalan kuasa. The wiring is connected properly to the power supply. F) Memasang Sengkuap Atas / Install Upper Canopy / Laraskan kedudukan Sengkuap Atas dan ketatkan skru pada Paip. Adjust the Upper Canopy position and screw the Upper Canopy to the Pipe. D Anggaran 5mm dari siling. D Approximately 5mm from the ceiling. D 5mm Sengkuap Atas / Upper Canopy / Paip / Pipe / Tandakan / Check / D 10

11 L Pemeriksaan Selepas Pemasangan / Check Point After Installation / Tandakan / Check / 1. Pastikan Skru Sengkuap Atas dipasang dengan betul. Ensure the Upper Canopy is securely fi xed. G) Bagaimana Memasang Pengawal Kelajuan / How To Install The Regulator / 1 Keluarkan skru daripada penutup Pengawal Kelajuan. Buka Penutup Pengawal Kelajuan dengan mengangkat Penutup Pengawal Kelajuan ke atas daripada Tapak. Remove the screw from the Regulator Cover. Remove the Regulator Cover by lifting up the Regulator Cover from the Base. Penutup Pengawal Kelajuan / Regulator Cover / Buka / Remove / Tapak / Base / 2 Pasangkan tapak Pengawal Kelajuan ke dinding seperti yang ditunjukkan. Fix the Regulator base to the wall as shown. Tarik wayar hidup keluar melalui lubang pada tapak. Insert the live wire from the wall through the hole at the base. Pastikan skru kayu yang digunakan bersaiz M4+18L. Make sure the wood screw size used is M4+18L. M4+18L Palam dinding tidak diperlukan bagi dinding kayu. The wall plugs are not needed for wooden wall. Perhatian : Skru Kayu dan Palam Dinding tidak disediakan bersama Kipas Siling. Note : The Wood Screws and the Wall Plugs are not provided with the Ceiling Fan. Ke Suis Pengawal Kelajuan / To Regulator Switch / Skru Kayu / Wood Screw / Wayar Hidup / Live Wire / Palam Dinding / Wall Plug / Lubang / Hole / Lubang / Hole / Tapak / Base / 60mm Dari Bekalan Kuasa / Fuse Power Supply / 3 Wayar hidup mesti disambung kepada Terminal dan diketatkan secukupnya seperti yang ditunjukkan. The live wire must be connected to the Terminal and be tightened fi rmly as shown. Ke Suis Pengawal Kelajuan / To Regulator Switch / Terminal / Terminal / Wayar Hidup / Live Wire / Tapak / Base / 4 Untuk menutup Pengawal Kelajuan, masukkan dua lubang yang terdapat di bahagian atas Penutup Pengawal Kelajuan kepada kedua-dua bahagian yang terdapat pada bahagian Tapak. To close the Regulator, insert the two holes on top of the Regulator Cover to the two protruding parts at the Base. Penutup Pengawal Kelajuan / Regulator Cover / Lubang / Hole / Pandangan Atas / Top View / Bahagian Unjuran pada Tapak / Protruding Part on Base / Tutup / Close / Penutup Pengawal Kelajuan / Regulator Cover / Tapak / Base / 5 Pasangkan dan ketatkan semula Skru Penutup Pengawal Kelajuan. Fix and tighten back Regulator Cover by Screw. Penutup Pengawal Kelajuan / Regulator Cover / Skru / Screw / 11

12 H) Pengesahan Akhir / Final Confirmation / Ukur jarak kedudukan Bilah dengan menggunakan pita pengukur. Sila laraskan kedudukan Bilah Kipas untuk mendapat kedudukan yang sama dari siling kepada hujung Bilah, L (dalam ukuran 1mm). Measure the distance using a measuring tape. Please adjust all the Blades to get the equal distance from ceiling to the Blade Tip, L (within 1 mm tolerance). 1 L AWAS / CAUTION / Selepas pemasangan pastikan Kipas Siling tidak bergoyang berlebihan. Boleh menyebabkan kecederaan jika Kipas Siling jatuh. After installation make sure the Ceiling Fan does not wobble extremely. Penyelenggaraan / Maintenance / Panduan Untuk Penyelenggaraan Yang Lebih Baik / Guide To Better Maintenance / 1. Periksa keadaan kipas sekali setahun. Sekiranya timbul masalah, berhenti menggunakan kipas. Kemudian rujuk kepada kedai servis, jualan atau penyelenggaraan. Periksa: Skru longgar, keadaan Wayar Keselamatan, kerosakan Aci Motor, dan lain-lain. Check the fan condition annually. If a problem occurs, stop using the fan. Then refer to service, sales or maintenance shop. Check points : Loosened Screws, Safety Wire condition, Motor Shaft damage, etc. 2. Kekalkan kebersihan kipas dengan mengelap kotoran dengan menggunakan kain yang bersih dan lembut, sabun biasa dan air. Lapkan sekali lagi untuk mengeringkannya. Jangan gunakan minyak pelincir (gasolin atau petrol). Jangan bengkokkan Bilah Kipas ketika membersihkannya. Keep the fan clean. Wipe away dirt with a clean soft cloth, ordinary soap and water. Wipe it again to dry it. Do not use solvents (gasoline or petrol). Please do not bend the Blade while cleaning. 3. Jangan cat Bilah Kipas. Sekiranya terdapat kerosakan, pesan set Bilah Kipas baru (3 unit) daripada kedai servis atau jualan. Do not paint the Blades. If damage, order new set of Blades (3 pieces) from service shop or sales shop Apabila merujuk kepada kedai servis, jualan atau penyelenggaraan, tunjukkan arahan ini kepada mereka agar penyelenggaraan yang betul dapat dijalankan. When referring to service, sales or maintenance shop, show this instruction to them and maintain correctly. 5. Jika produk pecah atau rosak, sila buka produk atau gantikan dengan produk yang baru. Ini adalah untuk mengelakkan Kipas Siling If the product is broken or damage, please dismantle the product or replace with the new product from ceiling. This is to avoid the Ceiling Fan drops. Spesifikasi Produk / Product Specification / BEKALAN KUASA POWER INPUT NOMBOR MODEL MODEL NO. KUASA (W) WATTAGE PUTARAN (RPM) ROTATION (RPM) RENDAH LOW TINGGI HIGH 240V~ 50Hz KELAJUAN ANGIN AIR VELOCITY m/min m/min SEBARAN ANGIN AIR DELIVERY m 3 /min m 3 /min BERAT BERSIH NET WEIGHT kg kg F-M15A ~ ~ F-M12A ~ ~ F-M15B ~ ~ M15A08001EM Panasonic Manufacturing Malaysia Berhad (6100-K) No. 3, Jalan Sesiku 15/2, Shah Alam Industrial Site, Shah Alam, Selangor Darul Ehsan, Malaysia. Printed in Malaysia 12

Panduan Penggunaan Dan Pemasangan Operating and Installation Instructions

Panduan Penggunaan Dan Pemasangan Operating and Installation Instructions Panduan Penggunaan Dan Pemasangan Operating and Installation Instructions Kipas Elektrik (Kipas Siling) Electric Fan (Ceiling Fan) Terima Kasih kerana membeli produk Panasonic. Thank you for purchasing

More information

Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions

Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions Kipas Elektrik (Kipas Siling) Electric Fan (Ceiling Fan) OFF/ON YURAGI 2 3 4 5 SPEED 3 6h CANCEL OFF TIMER SLEEP MODE Nombor Model

More information

Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions

Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions Panduan Penggunaan Dan Pemasangan Operating And Installation Instructions Kipas Elektrik (Kipas Siling) Electric Fan (Ceiling Fan) OFF/ON 2 3 4 5 SPEED 3 6h CANCEL OFF TIMER SLEEP MODE Nombor Model Model

More information

Panduan Penggunaan Dan Pemasangan Operating and Installation Instructions

Panduan Penggunaan Dan Pemasangan Operating and Installation Instructions Panduan Penggunaan Dan Pemasangan Operating and Installation Instructions Kipas Elektrik (Kipas Siling) Electric Fan (Ceiling Fan) Nombor Model Model Number F-M15H2 (1500mm) Terima Kasih kerana membeli

More information

PEMBERSIH VAKUM PANDUAN PENGGUNA MODEL: MVC-14P-OR & MVC-14P-GR

PEMBERSIH VAKUM PANDUAN PENGGUNA MODEL: MVC-14P-OR & MVC-14P-GR PEMBERSIH VAKUM PANDUAN PENGGUNA MODEL: MVC-14P-OR & MVC-14P-GR SILA BACA BUKU PANDUAN INI DENGAN TELITI SEBELUM PENGGUNAAN DAN SIMPAN DENGAN BAIK UNTUK RUJUKAN KELAK. LANGKAH-LANGKAH KESELAMATAN Untuk

More information

PANDUAN PENGGUNAAN PEMBERSIH VAKUM

PANDUAN PENGGUNAAN PEMBERSIH VAKUM PANDUAN PENGGUNAAN PEMBERSIH VAKUM Model: MVC-14D Voltan: 220-240V Frekuensi: 50/60Hz Kuasa maksimum: 1800W Kuasa Sedutan: 250W SILA BACA BUKU PANDUAN INI DENGAN TELITI SEBELUM PENGGUNAAN DAN DISIMPAN

More information

Raffica45-5BL/Raffica56-5BL

Raffica45-5BL/Raffica56-5BL Raffica4-BL/Raffica6-BL 用户手册 FIAMMA TRADING SDN.BHD -,Wisma Fiamma,NO.0.Jalan 7A/6A,Bandar Manjalara,00 Kuala Lumpur Website:www.rubine.com.my Raffica4-BL/Raffica6-BL POWER ON/OFF 4 R/F TURBO Sleep + BUNGKUSA

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RAS-X18CX/RAC-X18CX OUTDOOR UNIT INDOOR UNIT RAS-X18CX RAC-X18CX Instruction manual Page 1~22 To obtain the best performance and ensure

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT MODEL RAS-13CE9S/RAC-13CE9S OUTDOOR UNIT INDOOR UNIT RAS-13CE9S RAC-13CE9S Instruction manual Page 1~26 To obtain the best performance and ensure years of trouble free

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-X10CY / RAC-X10CY RAS-X13CY / RAC-X13CY OUTDOOR UNIT INDOOR UNIT HITACHI RAC-X10CY RAC-X13CY RAS-X10CY RAS-X13CY Instruction manual

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RAS-F13CF / RAC-F13CF OUTDOOR UNIT INDOOR UNIT RAC-F13CF RAS-F13CF Instruction manual Page 1~20 To obtain the best performance, please

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-18CE9G/RAC-18CX9 RAS-24CE9G/RAC-24CX9 INDOOR UNIT OUTDOOR UNIT RAS-18CE9G RAS-24CE9G RAC-18CX9 RAC-24CX9 Instruction manual Page 1~28 To obtain the

More information

FIBER NETWORK CABLING. By: Abdul Hak Bin Mahat (ILPS)

FIBER NETWORK CABLING. By: Abdul Hak Bin Mahat (ILPS) FIBER NETWORK CABLING By: TAJUK : Keselamatan Menggunakan Fiber Optik Oleh: TUJUAN Pelajar-pelajar mestilah boleh: Terangkan isu keselamatan dalam bidang fiber optik Terangkan tujuan keselamatan semasa

More information

PANDUAN PENGGUNAAN PEMBERSIH VAKUM

PANDUAN PENGGUNAAN PEMBERSIH VAKUM PANDUAN PENGGUNAAN PEMBERSIH VAKUM Model: MVC-16T-B/MVC-16T-GN/MVC-16T-R Voltan: 220-240V Kuasa maksimum: 600W Frekuensi: 50/60Hz Kuasa sedut i: 100W SILA BACA BUKU PANDUAN INI DENGAN TELITI SEBELUM PENGGUNAAN

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RAS-10C9G/RAC-10C9G RAS-13C9G/RAC-13C9G OUTDOOR UNIT INDOOR UNIT RAC-10C9G RAC-13C9G RAS-10C9G RAS-13C9G Instruction manual Page 1~20 To

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-E18CY(J) / RAC-18C9(J) OUTDOOR UNIT INDOOR UNIT RAS-E18CY(J) RAC-18C9(J) Instruction manual Page 1~22 To obtain the best performance,

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RAS-X10CD/RAC-SX10CD RAS-X13CD/RAC-SX13CD OUTDOOR UNIT INDOOR UNIT RAC-SX10CD RAC-SX13CD RAS-X10CD RAS-X13CD Instruction manual Page 1~24

More information

PEMBERSIH VAKUM PANDUAN PENGGUNA. No. Model: MVC-V12K-GR SILA BACA ARAHAN-ARAHAN KESELAMATAN SEBELUM PENGGUNAAN

PEMBERSIH VAKUM PANDUAN PENGGUNA. No. Model: MVC-V12K-GR SILA BACA ARAHAN-ARAHAN KESELAMATAN SEBELUM PENGGUNAAN PEMBERSIH VAKUM PANDUAN PENGGUNA No. Model: MVC-V12K-GR SILA BACA ARAHAN-ARAHAN KESELAMATAN SEBELUM PENGGUNAAN DAN SIMPAN DENGAN BAIK UNTUK RUJUKAN KELAK. STRUKTUR PRODUK 9 6 12 2 10 1 4 8 7 11 3 5 1

More information

PANDUAN PENGGUNAAN PEMBERSIH VAKUM

PANDUAN PENGGUNAAN PEMBERSIH VAKUM PANDUAN PENGGUNAAN PEMBERSIH VAKUM Model: MVC-15P Penyesuai voltan: 100-240V Kuasa maksimum: 100W Penyesuai frekuensi: 50/60Hz Bateri: 14.4V 1500mA Ni-MH SILA BACA BUKU PANDUAN INI DENGAN TELITI SEBELUM

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-X10CB / RAC-SX10CB RAS-XE10CC / RAC-SX10CB RAS-X13CB / RAC-SX13CB OUTDOOR UNIT INDOOR UNIT RAC-SX10CB RAC-SX13CB RAS-X10CB RAS-XE10CC

More information

USCI. PHYSICS Workshop Success is depend on your mind and your will. You are the one, who decide it. PROVE IT!! Speaker : Thong KS

USCI. PHYSICS Workshop Success is depend on your mind and your will. You are the one, who decide it. PROVE IT!! Speaker : Thong KS PHYSICS Workshop 2017 USCI Success is depend on your mind and your will. You are the one, who decide it. PROVE IT!! Speaker : Thong KS 1 www.guruthong.wordpress.com USCI Workshop 2017 1. Rajah 3.1 menunjukkan

More information

2 Sleep KUANTITI 零件 1 HANGING 吊杆. x 1 set. x 1 2 RECEIVER / x 1 10 x 1. x 1. 4 x 1. x 1. x 1 VOLTAGE 38W 数量 螺丝包 数量. 11 x 1 KUNCI ALLEN/ 内六角扳手

2 Sleep KUANTITI 零件 1 HANGING 吊杆. x 1 set. x 1 2 RECEIVER / x 1 10 x 1. x 1. 4 x 1. x 1. x 1 VOLTAGE 38W 数量 螺丝包 数量. 11 x 1 KUNCI ALLEN/ 内六角扳手 用户手册 POWER OFF 4 R/F 1 5 3 TURBO 2 Sleep 1 HANGING 吊杆 2 RECEIVER / 3 KUANTITI 零件 数量 螺丝包 数量 x 1 4 x 1 接头罩 x 1 5 风扇电机 x 1 BU NGKUSA 9 BALANCING KIT/ SET PENGIMBANGAN/ 平衡包 x 1 set x 1 10 x 1 SKRU BILAH/ 叶片螺丝

More information

LEAD THE CHANGE USER MANUAL/PANDUAN PENGGUNA/用户手册 CEILING FAN/KIPAS SILING/吊扇. Intero60 3BL (BK/PW/WH) MODEL/MODEL/型号. Intero60 3BL (BK/PW/WH)

LEAD THE CHANGE USER MANUAL/PANDUAN PENGGUNA/用户手册 CEILING FAN/KIPAS SILING/吊扇. Intero60 3BL (BK/PW/WH) MODEL/MODEL/型号. Intero60 3BL (BK/PW/WH) LEAD THE CHANGE Intero60 3BL (BK/PW/WH) USER MANUAL/PANDUAN PENGGUNA/用户手册 MODEL/MODEL/型号 FIAMMA TRADING SDN.BHD 2-,Wisma Fiamma,NO.20.Jalan 7A/62A,Bandar Manjalara,2200 Kuala Lumpur Website:www.rubine.com.my

More information

PANDUAN PENGGUNAAN PEMBERSIH VAKUM

PANDUAN PENGGUNAAN PEMBERSIH VAKUM PANDUAN PENGGUNAAN PEMBERSIH VAKUM Model: MVC-13M-B Penyesuai voltan: 220-240V Kuasa maksimum: 1800W Penyesuai frekuensi: 50/60Hz Kuasa Sedutan: 250W SILA BACA BUKU PANDUAN INI DENGAN TELITI SEBELUM PENGGUNAAN

More information

PROJEK PERUMAHAN KAWASAN PULAU

PROJEK PERUMAHAN KAWASAN PULAU PROJEK PERUMAHAN KAWASAN PULAU DESKRIPSI KERJA BAHAGIAN PERUMAHAN Memastikan ke semua peralatan elektrikal, mekanikal dan sivil yang berada di dalam bangunan berfungsi dengan baik. Mengatur dan merancang

More information

Azur GC4340, GC4330, GC4320, GC4310

Azur GC4340, GC4330, GC4320, GC4310 Azur G4340, G4330, G4320, G4310 2 ENGLISH 4 BAHASA MELAYU 12 21 29 37 45 G4340, G4330, G4320, G4310 4 ENGLISH Important Read these instructions for use carefully before using the appliance and save them

More information

INSTRUCTION: This section consists of SIX (6) structure questions. Answer FOUR (4) questions only.

INSTRUCTION: This section consists of SIX (6) structure questions. Answer FOUR (4) questions only. INSTRUCTION: This section consists of SIX (6) structure questions. Answer FOUR (4) questions only. ARAHAN: Bahagian ini mengandungi ENAM (6) soalan struktur. Jawab EMPAT (4) soalan sahaja. QUESTION 1 SOALAN

More information

SJ-285M SJ-325M PETI SEJUK - PENYEJUK BEKU MANUAL KENDALIAN KANDUNGAN. 㼓䙨ਙ䴱ߦ 䃠᱄ᴮ ⴤ䤺 REFRIGERATOR - FREEZER OPERATION MANUAL CONTENTS

SJ-285M SJ-325M PETI SEJUK - PENYEJUK BEKU MANUAL KENDALIAN KANDUNGAN. 㼓䙨ਙ䴱ߦ 䃠᱄ᴮ ⴤ䤺 REFRIGERATOR - FREEZER OPERATION MANUAL CONTENTS PETI SEJUK - PENYEJUK BEKU MANUAL KENDALIAN KANDUNGAN つ五 HFC-134a 㐙Ⲳ ᶆѱ㾷ᡆԳ ᡀ Refrigerant; HFC-134a Insulation blowing gas; Cyclopentane 2!" AMARAN................................ 2!" AWAS...................................

More information

Operating and Installation Instructions

Operating and Installation Instructions Operating and Installation Instructions Ceiling Fan Model No. / No. Model / 型号 K18NY Operating and Installation Instructions Ceiling Fan Thank you for purchasing this KDK product. Before operating this

More information

ASSESSMENT OF PARKING DEMAND IMPACT ON ADJOINING ROADWAY NETWORK WAN NUR ALIFFA WAN RAMLI

ASSESSMENT OF PARKING DEMAND IMPACT ON ADJOINING ROADWAY NETWORK WAN NUR ALIFFA WAN RAMLI ASSESSMENT OF PARKING DEMAND IMPACT ON ADJOINING ROADWAY NETWORK WAN NUR ALIFFA WAN RAMLI A project report submitted in partial fulfillment of the requirements for the award of the degree of Master of

More information

SECTION A : 50 MARKS BAHAGIAN A : 50 MARKAH INSTRUCTION: This section consists of TWO (2) structured essay questions. Answer ALL questions.

SECTION A : 50 MARKS BAHAGIAN A : 50 MARKAH INSTRUCTION: This section consists of TWO (2) structured essay questions. Answer ALL questions. SECTION A : 50 MARKS BAHAGIAN A : 50 MARKAH INSTRUCTION: This section consists of TWO (2) structured essay questions. Answer ALL questions. ARAHAN : Bahagian ini mengandungi DUA (2) soalan esei berstruktur.

More information

PRELIMINARY STUDY ON BRICKS DRYING PROCESS USING MICROWAVE TECHNOLOGY SALEM SALAH ABDULLAH BAGABER UNIVERSITI TEKNOLOGI MALAYSIA

PRELIMINARY STUDY ON BRICKS DRYING PROCESS USING MICROWAVE TECHNOLOGY SALEM SALAH ABDULLAH BAGABER UNIVERSITI TEKNOLOGI MALAYSIA PRELIMINARY STUDY ON BRICKS DRYING PROCESS USING MICROWAVE TECHNOLOGY SALEM SALAH ABDULLAH BAGABER UNIVERSITI TEKNOLOGI MALAYSIA 3 PRELIMINARY STUDY ON BRICKS DRYING PROCESS USING MICROWAVE TECHNOLOGY

More information

RDG 334 Theory and History of Design (Sejarah dan Teori Seni Reka)

RDG 334 Theory and History of Design (Sejarah dan Teori Seni Reka) UNIVERSITI SAINS MALAYSIA First Semester Examination 2013/2014 Academic Session December 2013 / January 2014 RDG 334 Theory and History of Design (Sejarah dan Teori Seni Reka) Duration : 3 hours (Masa:

More information

EME 431 Refrigeration & Air Conditioning [Penyejukan & Penyamanan Udara]

EME 431 Refrigeration & Air Conditioning [Penyejukan & Penyamanan Udara] -1- UNIVERSITI SAINS MALAYSIA First Semester Examination 2013/2014 Academic Session December 2013/January 2014 EME 431 Refrigeration & Air Conditioning [Penyejukan & Penyamanan Udara] Duration : 3 hours

More information

EVALUATION OF CRACK RELIEF LAYER FOR ROADS AND HIGHWAYS KHAIRUL HAFIZ BIN MUSTAFA

EVALUATION OF CRACK RELIEF LAYER FOR ROADS AND HIGHWAYS KHAIRUL HAFIZ BIN MUSTAFA EVALUATION OF CRACK RELIEF LAYER FOR ROADS AND HIGHWAYS KHAIRUL HAFIZ BIN MUSTAFA A project report submitted in partial fulfillment of the requirements for the award of the degree of Master of Engineering

More information

AQUAPONIC SYSTEM FOR SELF-SUSTAIN LIVING YAN YEN QUN

AQUAPONIC SYSTEM FOR SELF-SUSTAIN LIVING YAN YEN QUN iv AQUAPONIC SYSTEM FOR SELF-SUSTAIN LIVING YAN YEN QUN A dissertation submitted in fulfilment of the requirements for the award of the degree of Master of Architecture Faculty of Built Environment Universiti

More information

KAJIAN INOVASI PENGUNCIAN TURAPAN BLOK KONKRIT

KAJIAN INOVASI PENGUNCIAN TURAPAN BLOK KONKRIT KAJIAN INOVASI PENGUNCIAN TURAPAN BLOK KONKRIT Khairul Anwar b. Haji Husin 1, M.E. dan Muzani Mustapa 2 1 Fakulti Kejuruteraan & Pengajian Teknikal, Open Universiti Malaysia kayrool@hotmail.com 2 Fakulti

More information

UNIVERSITI TEKNIKAL MALAYSIA MELAKA. Improving of Cool Air Evacuation Process for Home Application

UNIVERSITI TEKNIKAL MALAYSIA MELAKA. Improving of Cool Air Evacuation Process for Home Application UNIVERSITI TEKNIKAL MALAYSIA MELAKA Improving of Cool Air Evacuation Process for Home Application This report submitted in accordance with requirement of the Universiti Teknikal Malaysia Melaka (UTeM)

More information

DEFINISI TEKNOLOGI HIJAU

DEFINISI TEKNOLOGI HIJAU DEFINISI TEKNOLOGI HIJAU Teknologi hijau merujuk kepada pembangunan dan aplikasi produk, peralatan serta sistem untuk memulihara alam sekitar dan sumber semula jadi dan meminimumkan atau mengurangkan kesan

More information

IDENTIFICATION OF AUDIO AND ROOM PARAMETERS FOR OPTIMUM SPEECH INTELLIGIBILITY IN ROOM NG TSING CHUN UNIVERSITI TEKNOLOGI MALAYSIA

IDENTIFICATION OF AUDIO AND ROOM PARAMETERS FOR OPTIMUM SPEECH INTELLIGIBILITY IN ROOM NG TSING CHUN UNIVERSITI TEKNOLOGI MALAYSIA IDENTIFICATION OF AUDIO AND ROOM PARAMETERS FOR OPTIMUM SPEECH INTELLIGIBILITY IN ROOM NG TSING CHUN UNIVERSITI TEKNOLOGI MALAYSIA ii I declare that this thesis entitled Identification of Audio and Room

More information

FLOOD MAPPING FOR SUNGAI BUNUS MOHD IRSYAM NOORFAWANA BIN MASRI

FLOOD MAPPING FOR SUNGAI BUNUS MOHD IRSYAM NOORFAWANA BIN MASRI FLOOD MAPPING FOR SUNGAI BUNUS MOHD IRSYAM NOORFAWANA BIN MASRI A project report submitted in fulfilment of the requirements for the award of the degree of Master of Engineering (Hydrology & Water Resources)

More information

MK-17S18D MK-17SS HOW TO USE CLEANING 技术要求 ( 版本号 : A, )

MK-17S18D MK-17SS HOW TO USE CLEANING 技术要求 ( 版本号 : A, ) 重点校对项 1. 版面尺寸 A 1 2 3 4 5 6 项目库文件名 A 2. 材质标注 3. 物料编码 4. 颜色标注 B B 5. 客户型号 6. 产品名称 7. 重量标注 C MK-17S18D MK-17SS IMPORTANT SAFETY INSTRUCTION BRIEF INTRODUCTION C 8. 电压功率 PRODUCT PARTS NAME D PRODUCT SPECIFICATION

More information

UNIVERSITI PUTRA MALAYSIA INTEGRATING PUBLIC ART IN MALAYSIAN URBAN LANDSCAPE

UNIVERSITI PUTRA MALAYSIA INTEGRATING PUBLIC ART IN MALAYSIAN URBAN LANDSCAPE UNIVERSITI PUTRA MALAYSIA INTEGRATING PUBLIC ART IN MALAYSIAN URBAN LANDSCAPE MOHD FABIAN BIN HASNA FRSB 2012 19 INTEGRATING PUBLIC ART IN MALAYSIAN URBAN LANDSCAPE By MOHD FABIAN BIN HASNA February 2012

More information

EARHTHING PERFORMANCE OF HV/MV SUBSTATION AND ITS EFFECT ON NEARBY STRUCTURES NORNIKMAN BIN RAHIMIN

EARHTHING PERFORMANCE OF HV/MV SUBSTATION AND ITS EFFECT ON NEARBY STRUCTURES NORNIKMAN BIN RAHIMIN EARHTHING PERFORMANCE OF HV/MV SUBSTATION AND ITS EFFECT ON NEARBY STRUCTURES NORNIKMAN BIN RAHIMIN A project report submitted in partial fulfilment of the requirements for the award of the degree of Master

More information

Final Year Project Report

Final Year Project Report FAKULTI KEJURUTERAAN ELEKTRIK UNIVERSITI TEKNIKAL MALAYSIA MELAKA 2014/2015 Final Year Project Report Mobile Air Conditioning Device CHIN KAR GHAI BACHELOR IN MECHATRONICS ENGINEERING (BEKM) 2014/2015

More information

COMPLEXITY OF THE FLORAL PATTERN IN VENTILATION PANEL OF TIMBER BUILDING IN KELANTAN AND TERENGGANU

COMPLEXITY OF THE FLORAL PATTERN IN VENTILATION PANEL OF TIMBER BUILDING IN KELANTAN AND TERENGGANU COMPLEXITY OF THE FLORAL PATTERN IN VENTILATION PANEL OF TIMBER BUILDING IN KELANTAN AND TERENGGANU NURSURIANI BINTI SHAFFEE UNIVERSITI TEKNOLOGI MALAYSIA iv COMPLEXITY OF THE FLORAL PATTERN IN VENTILATION

More information

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2008/2009. April/May RPK Urban Design [Rekabentuk Bandar]

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2008/2009. April/May RPK Urban Design [Rekabentuk Bandar] UNIVERSITI SAINS MALAYSIA Second Semester Examination Academic Session 2008/2009 April/May 2009 RPK 332 - Urban Design [Rekabentuk Bandar] Duration: 2 hours [Masa: 2 jam] Please check that this examination

More information

PHYSICAL ATTRIBUTES ON PLACE ATTACHMENT IN MALAYSIAN URBAN PARKS HADI EBADI UNIVERSITI TEKNOLOGI MALAYSIA

PHYSICAL ATTRIBUTES ON PLACE ATTACHMENT IN MALAYSIAN URBAN PARKS HADI EBADI UNIVERSITI TEKNOLOGI MALAYSIA PHYSICAL ATTRIBUTES ON PLACE ATTACHMENT IN MALAYSIAN URBAN PARKS HADI EBADI UNIVERSITI TEKNOLOGI MALAYSIA PHYSICAL ATTRIBUTES ON PLACE ATTACHMENT IN MALAYSIAN URBAN PARKS HADI EBADI A thesis submitted

More information

A Suitable Development Trend in Linear City Based On Smart Growth A Case Study in Lanzhou Urban Area ZHOU WEI

A Suitable Development Trend in Linear City Based On Smart Growth A Case Study in Lanzhou Urban Area ZHOU WEI A Suitable Development Trend in Linear City Based On Smart Growth A Case Study in Lanzhou Urban Area ZHOU WEI A project report submitted in partial fulfillment of the requirements for the award of the

More information

RINGKASAN EKSEKUTIF INTERNATIONAL FESTIVAL OF CULTURES (IFOC) 2013 TARIKH 1 DISEMBER 2013 TEMPAT KOLEJ AMINUDDIN BAKI

RINGKASAN EKSEKUTIF INTERNATIONAL FESTIVAL OF CULTURES (IFOC) 2013 TARIKH 1 DISEMBER 2013 TEMPAT KOLEJ AMINUDDIN BAKI RINGKASAN EKSEKUTIF INTERNATIONAL FESTIVAL OF CULTURES (IFOC) 2013 TARIKH TEMPAT ANJURAN BIRO KEBUDAYAAN DAN WARISAN, BIRO INTEGRASI DAN PERPADUAN KAUM & BIRO PEMBANGUNAN KEROHANIAN DAN SIVIK, MAJLIS EKSEKUTIF

More information

A COMPARISON BETWEEN TRADITIONAL PAVEMENT REHABILITATION METHOD AS COMPARED TO RECYCLING METHOD SITI MAZZUANA BINTI SHAMSUDDIN

A COMPARISON BETWEEN TRADITIONAL PAVEMENT REHABILITATION METHOD AS COMPARED TO RECYCLING METHOD SITI MAZZUANA BINTI SHAMSUDDIN A COMPARISON BETWEEN TRADITIONAL PAVEMENT REHABILITATION METHOD AS COMPARED TO RECYCLING METHOD SITI MAZZUANA BINTI SHAMSUDDIN A project report submitted in partial fulfilment of the requirements for the

More information

LANDFILL SITE SUITABILITY USING GEOGRAPHIC INFORMATION SYSTEM AND ANALYTICAL HIERARCHY PROCESS

LANDFILL SITE SUITABILITY USING GEOGRAPHIC INFORMATION SYSTEM AND ANALYTICAL HIERARCHY PROCESS i LANDFILL SITE SUITABILITY USING GEOGRAPHIC INFORMATION SYSTEM AND ANALYTICAL HIERARCHY PROCESS IZNI IZZATI BINTI MOHAMAD UNIVERSITI TEKNOLOGI MALAYSIA LANDFILL SITE SUITABILTY USING GEOGRAPHIC INFORMATION

More information

UNIVERSITI PUTRA MALAYSIA

UNIVERSITI PUTRA MALAYSIA UNIVERSITI PUTRA MALAYSIA FACIAL FEATURE EXTRACTION BASED ON IMPROVED HARRIS CORNER DETECTION ALGORITHM ELHAAM BAGHERIAN FSKTM 2011 9 FACIAL FEATURE EXTRACTION BASED ON IMPROVED HARRIS CORNER DETECTION

More information

SMART GARDEN SYSTEM NURSHAHNEEM BINTI MOHD SAID

SMART GARDEN SYSTEM NURSHAHNEEM BINTI MOHD SAID i SMART GARDEN SYSTEM NURSHAHNEEM BINTI MOHD SAID This Report Is Submitted In Partial Fulfillment of Requirements For The Bachelor Degree of Electronic Engineering (Industrial Electronic) Faculty of Electronic

More information

Kuliah 1 : Pengenalan Kepada Teknologi Maklumat & Komunikasi

Kuliah 1 : Pengenalan Kepada Teknologi Maklumat & Komunikasi PPISMP Kuliah 1 : Pengenalan Kepada Teknologi Maklumat & Komunikasi 1.2 Impak Teknologi Maklumat dan Komunikasi kepada Masyarakat 1.2.0 Impak Teknologi Maklumat dan Komunikasi kepada Masyarakat 1.2.1 Kepentingan

More information

MITSUBISHI HEAVY INDUSTRIES - MAHAJAK AIR CONDITIONERS CO., LTD. AIR-CONDITIONING & REFRIGERATION SYSTEMS

MITSUBISHI HEAVY INDUSTRIES - MAHAJAK AIR CONDITIONERS CO., LTD. AIR-CONDITIONING & REFRIGERATION SYSTEMS AIR-CONDITIONING & REFRIGERATION SYSTEMS 3-1, Asahi, Nishibiwajima-cho, Kiyosu, Aichi, 452-8561, Japan http://www.mhi.co.jp MITSUBISHI HEAVY INDUSTRIES - MAHAJAK AIR CONDITIONERS CO., LTD. 220 Lad Krabang

More information

ASSESSMENT OF URBAN GREEN SPACE BASED ON LANDSCAPE ECOLOGICAL PRINCIPLES SITI SYAMIMI BINTI OMAR

ASSESSMENT OF URBAN GREEN SPACE BASED ON LANDSCAPE ECOLOGICAL PRINCIPLES SITI SYAMIMI BINTI OMAR ASSESSMENT OF URBAN GREEN SPACE BASED ON LANDSCAPE ECOLOGICAL PRINCIPLES SITI SYAMIMI BINTI OMAR A dissertation for fulfilment of the requirements for the award of the degree of Master of Urban and Regional

More information

PETRONAS LESEN MEMBEKAL PERALATAN/MEMBERI PERKHIDMATAN KEPADA SYARIKAT-SYARIKAT CAIUGALI DAN PENGELUAR MINYAKIGAS DI MALAYSIA

PETRONAS LESEN MEMBEKAL PERALATAN/MEMBERI PERKHIDMATAN KEPADA SYARIKAT-SYARIKAT CAIUGALI DAN PENGELUAR MINYAKIGAS DI MALAYSIA 035654 PETRONAS ESEN MEMBEKA PERAATAN/MEMBERI PERKHIDMATAN KEPADA SYARIKAT-SYARIKAT CAIUGAI DAN PENGEUAR MINYAKIGAS DI MAAYSIA Pad a menjalankan kuasa-kuasa yang diberi oleh Seksyen 7, -Akta Kemajuan Petroliam,

More information

EWF EN WASHING MACHINE USER MANUAL 2 MS MESIN BASUH MANUAL PENGGUNA 65

EWF EN WASHING MACHINE USER MANUAL 2 MS MESIN BASUH MANUAL PENGGUNA 65 EWF 14012...... EN WASHING MACHINE USER MANUAL 2 MS MESIN BASUH MANUAL PENGGUNA 33 ZH 洗衣机 用户手册 65 2 www.electrolux.com CONTENTS 1 2 3 4 5 6 7 8 9 10 11 12 SAFETY INFORMATION... 3 PRODUCT DESCRIPTION...

More information

ULASAN UMUM BAGI DRAF MALAYSIAN STANDARDS YANG SEDANG DIBANGUNKAN, BAGI TEMPOH 1 OKTOBER NOVEMBER 2015

ULASAN UMUM BAGI DRAF MALAYSIAN STANDARDS YANG SEDANG DIBANGUNKAN, BAGI TEMPOH 1 OKTOBER NOVEMBER 2015 STD 093/6/4 1 Oktober 2015 ULASAN UMUM BAGI DRAF MALAYSIAN STANDARDS YANG SEDANG DIBANGUNKAN, BAGI TEMPOH 1 OKTOBER 2015 30 NOVEMBER 2015 Dengan segala hormatnya perkara di atas adalah dirujuk. Bersama

More information

EFFECT OF FINE AGGREGATE ANGULARITY ON RUTTING RESISTANCE OF ASPHALT CONCRETE AC10

EFFECT OF FINE AGGREGATE ANGULARITY ON RUTTING RESISTANCE OF ASPHALT CONCRETE AC10 EFFECT OF FINE AGGREGATE ANGULARITY ON RUTTING RESISTANCE OF ASPHALT CONCRETE AC10 IZZUL BIN RAMLI A project report submitted in partial fulfillment of the requirements for the award of the degree of Master

More information

A SIMPLE ID DETECTION USING INFRARED SENSORS NOOR FARHANA HALIL BT ABDUL RAZAK

A SIMPLE ID DETECTION USING INFRARED SENSORS NOOR FARHANA HALIL BT ABDUL RAZAK A SIMPLE ID DETECTION USING INFRARED SENSORS NOOR FARHANA HALIL BT ABDUL RAZAK This report is submitted in partial fulfillment of the requirements for the award of Bachelor of Electronic Engineering (

More information

BORANG PENGESAHAN STATUS TESIS

BORANG PENGESAHAN STATUS TESIS UNIVERSITI TEKNOLOGI MALAYSIA BORANG PENGESAHAN STATUS TESIS JUDUL: TAHAP PENGETAHUAN AMALAN KESELAMATAN MAKMAL SAINS DALAM KALANGAN GURU PELATIH SAINS, FAKULTI PENDIDIKAN, UNIVERSITI TEKNOLOGI MALAYSIA

More information

MOTORCYCLE ANTI-THEFT SYSTEM (MATS) MUHAMAD ALIF BIN ABU

MOTORCYCLE ANTI-THEFT SYSTEM (MATS) MUHAMAD ALIF BIN ABU MOTORCYCLE ANTI-THEFT SYSTEM (MATS) MUHAMAD ALIF BIN ABU This report is submitted in partial Fulfillment of Requirement for Bachelor of Electronic Engineering (Industrial Electronic) with Honours Faculty

More information

DESIGN FACTORS THAT INFLUENCE THE EFFECTIVE USE OF MEYDAN IN IRAN REIHANEH SADAT HAJMIRSADEGHI UNIVERSITI TEKNOLOGI MALAYSIA

DESIGN FACTORS THAT INFLUENCE THE EFFECTIVE USE OF MEYDAN IN IRAN REIHANEH SADAT HAJMIRSADEGHI UNIVERSITI TEKNOLOGI MALAYSIA DESIGN FACTORS THAT INFLUENCE THE EFFECTIVE USE OF MEYDAN IN IRAN REIHANEH SADAT HAJMIRSADEGHI UNIVERSITI TEKNOLOGI MALAYSIA DESIGN FACTORS THAT INFLUENCE THE EFFECTIVE USE OF MEYDAN IN IRAN REIHANEH SADAT

More information

UNIVERSITI PUTRA MALAYSIA DESIGN OF RADIX-4 SINGLE PATH DELAY FAST FOURIER TRANSFORM PROCESSOR WITH GENETIC ALGORITHMS OPTIMIZATION

UNIVERSITI PUTRA MALAYSIA DESIGN OF RADIX-4 SINGLE PATH DELAY FAST FOURIER TRANSFORM PROCESSOR WITH GENETIC ALGORITHMS OPTIMIZATION UNIVERSITI PUTRA MALAYSIA DESIGN OF RADIX-4 SINGLE PATH DELAY FAST FOURIER TRANSFORM PROCESSOR WITH GENETIC ALGORITHMS OPTIMIZATION PANG JIA HONG FK 2011 140 DESIGN OF RADIX-4 SINGLE PATH DELAY FAST FOURIER

More information

Salam Pengenalan F2F Pertama - pelajar KOM3305 (PJJ)

Salam Pengenalan F2F Pertama - pelajar KOM3305 (PJJ) Salam Pengenalan F2F Pertama - pelajar KOM3305 (PJJ) Prof Madya Dr. Siti Zobidah Omar Jabatan Komunikasi Fakulti Bahasa Moden dan Komunikasi Universiti Putra Malaysia Semester Kedua (Februari) 2017/2018

More information

SISTEM PENYEWAAN FASILITI MAJLIS SEHENTI (ONE STOP EVENT RENTAL SYSTEM)

SISTEM PENYEWAAN FASILITI MAJLIS SEHENTI (ONE STOP EVENT RENTAL SYSTEM) SISTEM PENYEWAAN FASILITI MAJLIS SEHENTI (ONE STOP EVENT RENTAL SYSTEM) D.PRABU A/L DADAYAN SABRINA TIUN Fakulti Teknologi & Sains Maklumat, Universiti Kebangsaan Malaysia ABSTRAK Sistem Penyewaan Fasiliti

More information

Table of contents. English 6. 한국어 20 Bahasa Melayu 27 ภาษาไทย 35 Tiếng Việt 41 繁體中文 48 简体中文 54 FC8278

Table of contents. English 6. 한국어 20 Bahasa Melayu 27 ภาษาไทย 35 Tiếng Việt 41 繁體中文 48 简体中文 54 FC8278 FC8278 1 33 Table of contents English 6 Indonesia 13 한국어 20 Bahasa Melayu 27 ภาษาไทย 35 Tiếng Việt 41 繁體中文 48 简体中文 54 FC8278 6 English Introduction Congratulations on your purchase and welcome to Philips!

More information

GAS LEAKAGE MONITORING OVER THE NET WITH RASPBERRY PI MOHD FAEZ BIN AHMAD RAZLI

GAS LEAKAGE MONITORING OVER THE NET WITH RASPBERRY PI MOHD FAEZ BIN AHMAD RAZLI i GAS LEAKAGE MONITORING OVER THE NET WITH RASPBERRY PI MOHD FAEZ BIN AHMAD RAZLI This Report Is Submitted In Partial Fulfillment of Requirements for the Bachelor Degree of Electronic Engineering (Industrial

More information

Analisa terhadap kaedah pengulasan laporan Penilaian Kesan kepada Alam Sekeliling (EIA) di Malaysia

Analisa terhadap kaedah pengulasan laporan Penilaian Kesan kepada Alam Sekeliling (EIA) di Malaysia 2017, ISSN 2180-2491 11 Analisa terhadap kaedah pengulasan laporan Penilaian Kesan kepada Alam Sekeliling (EIA) di Malaysia Abdul Rahman Mahmud 1, Zaini Sakawi 1, Khairul Nizam Abdul Maulud 2&3 1 Pusat

More information

WHAT IS LANDSCAPE? Webster s New Universal Unabridged Dictionary.

WHAT IS LANDSCAPE? Webster s New Universal Unabridged Dictionary. ENTER 1 WHAT IS LANDSCAPE? Landscape: a picture representing a section of natural, inland scenery, as of prairie, woodland, mountains...an expanse of natural scenery seen by the eye in one view. Webster

More information

SISTEM PENGURUSAN E-WASTE FTSM BERASASKAN WEB (SISE-WASTE)

SISTEM PENGURUSAN E-WASTE FTSM BERASASKAN WEB (SISE-WASTE) SISTEM PENGURUSAN E-WASTE FTSM BERASASKAN WEB (SISE-WASTE) ILLYANA KASIM AMELIA NATASYA ABDUL WAHAB Fakulti Teknologi & Sains Maklumat, Universiti Kebangsaan Malaysia ABSTRAK Pembangunan yang pesat dalam

More information

ANALYSIS AND MEASUREMENT FIBER OPTIC FAULT BY USING OPTICAL TIME DOMAIN REFLECTROMETER (OTDR) AKWANIZAM BIN AZMI

ANALYSIS AND MEASUREMENT FIBER OPTIC FAULT BY USING OPTICAL TIME DOMAIN REFLECTROMETER (OTDR) AKWANIZAM BIN AZMI ANALYSIS AND MEASUREMENT FIBER OPTIC FAULT BY USING OPTICAL TIME DOMAIN REFLECTROMETER (OTDR) AKWANIZAM BIN AZMI This Report Is Submitted in Partial Fulfillment of the Requirements for the award of Bachelor

More information

APPLICATION OF BIM IN EARLY STAGE DESIGN COST ESTIMATION

APPLICATION OF BIM IN EARLY STAGE DESIGN COST ESTIMATION APPLICATION OF BIM IN EARLY STAGE DESIGN COST ESTIMATION RAIHAN MASKURIY Faculty of Built Environment Universiti Teknologi Malaysia APPLICATION OF BIM IN EARLY STAGE DESIGN COST ESTIMATION RAIHAN MASKURIY

More information

UNIVERSITI PUTRA MALAYSIA CRITERIA AND INDICATORS FOR MALAYSIAN GARDEN CITY OF PUTRAJAYA

UNIVERSITI PUTRA MALAYSIA CRITERIA AND INDICATORS FOR MALAYSIAN GARDEN CITY OF PUTRAJAYA UNIVERSITI PUTRA MALAYSIA CRITERIA AND INDICATORS FOR MALAYSIAN GARDEN CITY OF PUTRAJAYA AMAT RAMSA YAMAN FH 2011 25 CRITERIA AND INDICATORS FOR MALAYSIAN GARDEN CITY OF PUTRAJAYA AMAT RAMSA YAMAN DOCTOR

More information

SISTEM PEMANTAUAN PENGURUSAN PROJEK TEKNOLOGI MAKLUMAT ( PROMIS ) PUSAT TEKNOLOGI MAKLUMAT DAN KOMUNIKASI SAMSUDIN BIN NYAT

SISTEM PEMANTAUAN PENGURUSAN PROJEK TEKNOLOGI MAKLUMAT ( PROMIS ) PUSAT TEKNOLOGI MAKLUMAT DAN KOMUNIKASI SAMSUDIN BIN NYAT SISTEM PEMANTAUAN PENGURUSAN PROJEK TEKNOLOGI MAKLUMAT ( PROMIS ) PUSAT TEKNOLOGI MAKLUMAT DAN KOMUNIKASI SAMSUDIN BIN NYAT Laporan projek ini dikemukakan sebagai memenuhi sebahagian daripada syarat penganugerahan

More information

ANALYSIS PERFORMANCE OF WAJA CAR AIR-CONDITIONING SYSTEM MUHAMAD AMIRUDIN BIN KAMALRUL BADRI

ANALYSIS PERFORMANCE OF WAJA CAR AIR-CONDITIONING SYSTEM MUHAMAD AMIRUDIN BIN KAMALRUL BADRI ANALYSIS PERFORMANCE OF WAJA CAR AIR-CONDITIONING SYSTEM MUHAMAD AMIRUDIN BIN KAMALRUL BADRI Thesis submitted in fulfilment of the requirements for the award of the degree of Bachelor of Mechanical Engineering

More information

GEOGRAPHICAL ANALYSIS OF LIBYAN AIRPORTS AND THEIR POTENTIAL AS A HUB OF AIR TRANSPORTATION FOUAD D S ABDULWAFI UNIVERSITI TEKNOLOGI MALAYSIA

GEOGRAPHICAL ANALYSIS OF LIBYAN AIRPORTS AND THEIR POTENTIAL AS A HUB OF AIR TRANSPORTATION FOUAD D S ABDULWAFI UNIVERSITI TEKNOLOGI MALAYSIA 1 GEOGRAPHICAL ANALYSIS OF LIBYAN AIRPORTS AND THEIR POTENTIAL AS A HUB OF AIR TRANSPORTATION FOUAD D S ABDULWAFI UNIVERSITI TEKNOLOGI MALAYSIA 4 GEOGRAPHICAL ANALYSIS OF LIBYAN AIRPORTS AND THEIR POTENTIAL

More information

STORAGE WATER TANKS CLEANING ROBOT AFIZRUL IMAN BIN MOHAMED

STORAGE WATER TANKS CLEANING ROBOT AFIZRUL IMAN BIN MOHAMED STORAGE WATER TANKS CLEANING ROBOT AFIZRUL IMAN BIN MOHAMED This report is submitted in partial fulfillment of requirement for the Bachelor Of Electronic Engineering (Industrial Electronics) With Honours

More information

Operating Instructions

Operating Instructions Operating Instructions Juicer (Household Use) 12 00 fl 7 0 2 12 00 7 0 2 fl TABLE OF CONTENTS SAFETY PRECAUTIONS... 2-4 PART NAMES... 5 DISASSEMBLY... 6 CIRCUIT BREAKER PROTECTION... 6 HOW TO USE... 7

More information

FENCE INTRUDER DETECTION SYSTEM (FIDS) CHUINK BENG CHEONG

FENCE INTRUDER DETECTION SYSTEM (FIDS) CHUINK BENG CHEONG FENCE INTRUDER DETECTION SYSTEM (FIDS) CHUINK BENG CHEONG This report is submitted in partial fulfillment of the requirements for the award of Bachelor of Electronic Engineering (Computer Engineering)

More information

Model: AC-108. Instruction Manual

Model: AC-108. Instruction Manual Model: AC-108 Instruction Manual Attention: This appliance is not intended for use by persons (including Children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge

More information

EME 431 Refrigeration & Air Conditioning [Penyejukan & Penyamanan Udara]

EME 431 Refrigeration & Air Conditioning [Penyejukan & Penyamanan Udara] UNIVERSITI SAINS MALAYSIA First Semester Examination Academic Session 2015/2016 December 2015 / January 2016 EME 431 Refrigeration & Air Conditioning [Penyejukan & Penyamanan Udara] Duration : 3 hours

More information

KETUHAR GELOMBANG MIKRO Petunjuk bagi Pemilik Ketuhar Gelombang Mikro dan cara memasak

KETUHAR GELOMBANG MIKRO Petunjuk bagi Pemilik Ketuhar Gelombang Mikro dan cara memasak KETUHAR GELOMBANG MIKRO Petunjuk bagi Pemilik Ketuhar Gelombang Mikro dan cara memasak M1630N / M1610N anduan Carian Pantas...2 Ketuhar...3 Aksesori...3 Panel Kawalan...4 Mengguna Buku Panduan Ini...5

More information

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

UNIVERSITI TEKNIKAL MALAYSIA MELAKA UNIVERSITI TEKNIKAL MALAYSIA MELAKA SMART HOME SECURITY SYSTEM BY USING GSM This report submitted in accordance with requirement of the Universiti Teknikal Malaysia Melaka (UTeM) for the Bachelor s Degree

More information

FIRE ALARM WITH SECURITY SYSTEM MOHAMED FAIZ BIN MOHAMED MUSA

FIRE ALARM WITH SECURITY SYSTEM MOHAMED FAIZ BIN MOHAMED MUSA FIRE ALARM WITH SECURITY SYSTEM MOHAMED FAIZ BIN MOHAMED MUSA This Report Is Submitted In Partial Fulfillment Of Requirements For The Bachelor Degree of Electronic Engineering (Telecommunication) Fakulti

More information

SIMULASI MESIN PELARIK BERASASKAN TEKNOLOGI AUGMENTED REALITY MUHAMAD IKRAM BIN ABDUL KARIM DR. SYAIMAK ABDUL SHUKOR

SIMULASI MESIN PELARIK BERASASKAN TEKNOLOGI AUGMENTED REALITY MUHAMAD IKRAM BIN ABDUL KARIM DR. SYAIMAK ABDUL SHUKOR SIMULASI MESIN PELARIK BERASASKAN TEKNOLOGI AUGMENTED REALITY MUHAMAD IKRAM BIN ABDUL KARIM DR. SYAIMAK ABDUL SHUKOR Fakulti Teknologi& Sains Maklumat, Universiti Kebangsaan Malaysia ABSTRAK Teknologi

More information

PLACENESS BAGI PASAR BESAR DAN BAZAR DI KAMPUNG JAWA, MELAKA AHMAD AMZAR BIN ABDULLAH

PLACENESS BAGI PASAR BESAR DAN BAZAR DI KAMPUNG JAWA, MELAKA AHMAD AMZAR BIN ABDULLAH PLACENESS BAGI PASAR BESAR DAN BAZAR DI KAMPUNG JAWA, MELAKA AHMAD AMZAR BIN ABDULLAH Disertasi ini dikemukakan sebagai memenuhi sebahagian daripada syarat penganugerahan Sarjana Sains (Rekabentuk Bandar)

More information

VISUAL REPRESENTATION OF NATURE IN THE LIBRARY SOMAYEH ROUSTAEI SADRY UNIVERSITI TEKNOLOGI MALAYSIA

VISUAL REPRESENTATION OF NATURE IN THE LIBRARY SOMAYEH ROUSTAEI SADRY UNIVERSITI TEKNOLOGI MALAYSIA VISUAL REPRESENTATION OF NATURE IN THE LIBRARY SOMAYEH ROUSTAEI SADRY UNIVERSITI TEKNOLOGI MALAYSIA VISUAL REPRESENTATION OF NATURE IN THE LIBRARY SOMAYEH ROUSTAEI SADRY A thesis submitted in partial fulfillment

More information

AIR CONDITIONING STUDY FOR AUTOMOTIVE APPLICATION ALAUDDIN HAFIZ BIN YUSOF UNIVERSITI MALAYSIA PAHANG

AIR CONDITIONING STUDY FOR AUTOMOTIVE APPLICATION ALAUDDIN HAFIZ BIN YUSOF UNIVERSITI MALAYSIA PAHANG AIR CONDITIONING STUDY FOR AUTOMOTIVE APPLICATION ALAUDDIN HAFIZ BIN YUSOF UNIVERSITI MALAYSIA PAHANG UNIVERSITI MALAYSIA PAHANG BORANG PENGESAHAN STATUS TESIS JUDUL: AIR CONDITIONING STUDY FOR AUTOMOTIVE

More information

SIMULASI MESIN PENGISAR BERASASKAN TEKNOLOGI AUGMENTED REALITY (A.R.) Mohd Fazreen Bin Abdul Pata Dr. Syaimak Abdul Shukor

SIMULASI MESIN PENGISAR BERASASKAN TEKNOLOGI AUGMENTED REALITY (A.R.) Mohd Fazreen Bin Abdul Pata Dr. Syaimak Abdul Shukor SIMULASI MESIN PENGISAR BERASASKAN TEKNOLOGI AUGMENTED REALITY (A.R.) Mohd Fazreen Bin Abdul Pata Dr. Syaimak Abdul Shukor Fakulti Teknologi & Sains Maklumat, Universiti Kebangsaan Malaysia ABSTRAK Teknologi

More information

DYNAMIC ANALYSES OF COMPOSITE FOOTBRIDGES EXCITED BY PEDESTRIAN INDUCED LOADS FARAZ SADEGHI UNIVERSITI TEKNOLOGI MALAYSIA

DYNAMIC ANALYSES OF COMPOSITE FOOTBRIDGES EXCITED BY PEDESTRIAN INDUCED LOADS FARAZ SADEGHI UNIVERSITI TEKNOLOGI MALAYSIA DYNAMIC ANALYSES OF COMPOSITE FOOTBRIDGES EXCITED BY PEDESTRIAN INDUCED LOADS FARAZ SADEGHI UNIVERSITI TEKNOLOGI MALAYSIA. DYNAMIC ANALYSES OF COMPOSITE FOOTBRIDGES EXCITED BY PEDESTRIAN INDUCED LOADS

More information

ASSESSING GREENWAY NETWORK CONNECTIVITY FOR UNIVERSITY CAMPUS NORAINI BT BAHARI

ASSESSING GREENWAY NETWORK CONNECTIVITY FOR UNIVERSITY CAMPUS NORAINI BT BAHARI ASSESSING GREENWAY NETWORK CONNECTIVITY FOR UNIVERSITY CAMPUS NORAINI BT BAHARI NOVEMBER 2010 ASSESSING GREENWAY NETWORK CONNECTIVITY FOR UNIVERSITI CAMPUS NORAINI BT BAHARI A thesis submitted in fulfillment

More information

Installation Instructions Ceiling Kit

Installation Instructions Ceiling Kit Installation Instructions Ceiling Kit Model No. ENGLISH FRANÇAIS ESPAÑOL * Above illustration is shown in combination of this product and optional projector. Thank you for purchasing this Panasonic product.

More information

BORANG PENGESAHAN STATUS TESIS

BORANG PENGESAHAN STATUS TESIS 1 UNIVERSITI TEKNOLOGI MALAYSIA BORANG PENGESAHAN STATUS TESIS JUDUL: REKABENTUK INSTRUMEN PENGERING KASUT MUDAH ALIH SESI PENGAJIAN: 2008/2009 Saya MOHAMED RAFI BIN M S SOLAIMAN (801019-01-5203) (HURUF

More information

NAZANEEN AHMED NASROULLA

NAZANEEN AHMED NASROULLA RELATIONSHIP BETWEEN CONE PENETRATION TEST AND UNDRAINED SHEAR STRENGTH OF SOFT SOIL NAZANEEN AHMED NASROULLA A project report submitted in partial fulfillment of the requirements for the award of degree

More information

A 11 TK Oxygen Bleach Powder. Powerful solutions for every demands Additional product range

A 11 TK Oxygen Bleach Powder. Powerful solutions for every demands Additional product range Powerful solutions for every demands Additional product range The additional product range from Winterhalter offers cleaning solutions for warewashers and dishes. Winterhalter offers the right product

More information

WIRELESS SECURITY SYSTEM UKASYAH BIN MAHAMOD

WIRELESS SECURITY SYSTEM UKASYAH BIN MAHAMOD i WIRELESS SECURITY SYSTEM UKASYAH BIN MAHAMOD This Report is submitted in partial fulfillment of the requirements for the award of Bachelor Electronic Engineering (Computer Engineering) with Honours Faculty

More information

Installation/Instruction Manual

Installation/Instruction Manual 1510876HC8902 Pressurized ventilators (for device cooling) Model Blade diameter (cm) Indoor or outdoor EF-20UYS-UL EF-25UAS-UL EF-30UBS-UL 20 25 30 Indoor Installation/Instruction Manual For customers

More information