Hydronic Accessories

Size: px
Start display at page:

Download "Hydronic Accessories"

Transcription

1 ydronic ccessories Zone Sentry Series The Taco Zone Sentry Zone Valve enhances the overall performance of any zone valve system. The unique patented technology in the Zone Sentry utilizes a microcircuit based logic to control a gear driven electronic actuator which drives a ball valve based body design. ll this adds up to a zone valve that leads the industry in energy efficiency, flow capacity (Cv), shutoff pressure rating, ease of installation, diagnostic capability and the number of valves (12) that can be use on a standard 40V transformer. Taco Catalog # ffective Date: 10/25/17 Supersedes: 05/30/16 Printed in US

2 Submittal Data # ffective: 10/25/17 Supersedes: 05/30/16 Zone Sentry Product Specifications Max. Operating Pressure PSI (2100 kpa) Max. Shutoff Pressure PSI (875 kpa) Max. mbient Temp luid Temp. Range ( C) Service...Water or Water/lycol up...to 50% lycol Close Systems (Open system option available) pplication: Taco Zone Sentry zone valves provide on-off, normally open or normally closed control in closed hydronic systems. (See eo-sentry for open system application) The valves can be used in a wide variety of heating and condensing cooling applications, primarily designed for use with baseboad, fan coils, radiators, convectors, air handlers, heat pumps and radiant applications. or Indoor Use Only Zone Sentry Dimensions: (OR RRNC PURPOSS) D C all Rotation Speed...(90 turn), pprox. 5 seconds (fter charge time) lectrical Rating...24 VC, 60z, 0.48 mps Power Consumption W, 0.48 mps Power Consumption W, 0.06 mps eat nticipator Setting mps nd Switch Rating VC ctuator: ody...igh Performance...ngineered Polymer ears...igh Performance Internally...Lubricated ngineered Polymer Valve:... ody...orged rass Stem...rass Press Ring...rass all...rass (Chrome Plated) Seat...Modified Teflon O-Rings...PDM C D (/Press) (Threaded) (3-way) in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 1/ " / " " Inverted lare 3/4 sweat fitting * ** N/ N/ 1/2, 3/4, 1 Press Connect *** 157 N/ N/ N/ N/ * Includes inverted flare fitting ** Less fittings *** Press Dimension NPT Z050T2 1/2" Z050C2 Z075T2 3/4" 2 way Z075C2 Z100T2 1" Z100C2 NPT Z050T3 1/2" 3-way Z050C3 Z075T3 3/4" 3-way Z075C3 Z100T3 1" 3-way Z100C3 Press Connect Size Inverted lare Z050P2 1/2" --- Z075P2 3/4" Z0752 Z100P2 1" --- ll models shown are normally closed. Consult factory for additional model numbers t 4 per second (Max. recommended residential flow rate) Valve Size Pipe quiv. 1/2 4.9 (4.3) / 9.5 1/2" Press 3.4 (2.9) / / (8.9) / 8.4 3/4" Press 9.5 (8.1) / (7.7) / " Press 7.5 (6.4) / 66.8 Inverted lare 3/4" SWT Pressure (kpa) Pipe quiv psi (0-862 kpa) 1.5 (1.3) / psi (0-862 kpa) 3.3 (2.8) / psi (0-862 kpa) 3.0 (2.6) / (3.0) / psi (0-862 kpa) N/

3 Submittal Data # ffective: 10/25/17 Supersedes: 05/30/16 eo-sentry pplication: The eo-sentry zone valve provides on/off, normally open or normally closed control and is especially suited for use in either open or closed loop geothermal systems with water source heat pumps. or Indoor Use Only Product Specifications Max. Operating Pressure PSI (2100 kpa) Max. Shutoff Pressure PSI (875 kpa) Max. mbient Temp...24V 135 / Multi-Volt 150 luid Temp. Range ( C) Service...Open and closed systems luids...water...up to25% thanol...up to25% Methanol...Up to50% lycol...steam 15 psi max. all Rotation Speed...(90 turn), pprox. 5 seconds (fter charge time) lectrical Rating...24 VC, 60z, 0.48 mps Power Consumption W, 0.48 mps Power Consumption W, 0.06 mps eat nticipator Setting mps nd Switch Rating VC ctuator:... ody...igh Performance D...ngineered Polymer C ears...igh Performance Internally...Lubricated ngineered Polymer Valve:... ody...orged rass Stem...rass Press Ring...rass all...rass (Chrome Plated) NOT: eo-sentry is also available with Multi-Volt actuator Seat...Modified Teflon O-Rings...PDM eo-sentry Dimensions: (OR RRNC PURPOSS) C D () (Threaded) (3-way) in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 1/ / / / / / / / /16" / / / / / / / / /8" / / / / / / / /2" NPT NPT Pipe quiv. ** Pressure (kpa) Pipe quiv. ** V050T22Z024Q41 1/2" V050T31Z024Q41 1/2" 3-way 1/2 4.9 (4.3) / psi (0-862 kpa) 1.5 (1.3) / 111 V075T22Z024Q41 3/4" 2 way V075T31Z024Q41 3/4" 3-way 3/ (8.9) / psi (0-862 kpa) 3.3 (2.8) / 82 V100T22Z024Q41 1" V100T31Z024Q41 1" 3-way (7.7) / psi (0-862 kpa) 3.0 (2.6) / 411 Consult factory for additional model numbers **t 4 per second (Max. recommended residential flow rate).

4 Submittal Data # ffective: 10/25/17 Supersedes: 05/30/16 Potable Water Zone Sentry (<.25% Lead) pplication: The Taco Potable Water Zone Sentry zone valve is available in a sweat configuration with either a normally open or normally closed actuator. Some typical installations would include a combination domestic water and hydronic heating system, culinary installation or water shut off to a potable system. or Indoor Use Only Product Specifications Max. Operating Pressure PSI (2100 kpa) Max. Shutoff Pressure PSI (875 kpa) luid Temp. Range (1-104 C) Service...Potable Water all Rotation Speed...(90 turn), pprox. 5 seconds (fter charge time) lectrical Rating...24 VC, 60z, 0.48 mps Power Consumption W, 0.48 mps Power Consumption W, 0.06 mps nd Switch Rating VC ctuator:... ody...igh Performance...ngineered Polymer ears...igh Performance Internally...Lubricated ngineered Polymer D C Valve:... ody...orged rass Stem...rass Press Ring...rass all...rass (Chrome Plated) Seat...Modified Teflon O-Rings...Viton Potable Water Zone Sentry Dimensions: (OR RRNC PURPOSS) Part Valve Valve C D Number Size Type in. mm in. mm in. mm in. mm in. mm in. mm in. mm V050C2D2Z024Q41 () 1/ V075C2D2Z024Q41 () 3/ V050C2D2Z024Q41 (Normally Open) 1/ V075C2D2Z024Q41 (Normally Open) 3/ Cv (Kv) / t. of Pipe quiv.** Pressure (kpa) 1/2 4.9 (4.3) / psi (0-862 kpa) 3/ (8.9) / psi (0-862 kpa) **t 4 per second (Max. recommended residential flow rate)

5 Submittal Data# ffective: 10/25/17 Supersedes: 05/30/16 Multi-Volt Zone Sentry Product Specifications Max. Operating Pressure PSI (2100 kpa) pplication: One valve takes the place of many. The Multi-Volt Zone Sentry will accept input voltages between 120 and 277VC 50/60Z. The Multi-Volt Zone Sentry zone valve is designed for use in hydronic VC systems, primarily in fan coils and air handlers or other VC systems where a quality line voltage zone valve is required. The Multi-Volt Zone Sentry can be installed in both heating and cooling applications and is available in a normally closed or normally open configuration. Max. Shutoff Pressure PSI (875 kpa) Max. mbient Temp luid Temp. Range ( C) Service...Closed systems...optional open system...configuration available...water/water and glycol...up to 50% Seat Leakage...Drop-Tight lectrical Rating VC to 277VC, 1Ph, 50/60z Power Consumption...4 Watts Power Consumption Watts Max. Duty Cycle...1 Cycle/Minute or Indoor Use Only ctuator:... ody...igh Performance...ngineered Polymer ears...igh Performance Internally...Lubricated ngineered Polymer Valve:... ody...orged rass Stem...rass Press Ring...rass all...rass (Chrome Plated) Seat...Modified Teflon O-Rings...PDM NOT: The Multi-Volt actuator is available on all versions of Zone Sentry Multi-Volt Zone Sentry Dimensions: (OR RRNC PURPOSS) C D () (Threaded) in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 1/2 2-5/ / / / / / / / /4 2-5/ / / / / / / / / / / / / / NPT NPT Valve Size Pipe quiv. * Pressure (kpa) Pipe quiv. * V050T22ZLNV21 1/2" V050C22ZLNV21 V050T31ZLNV21 1/2" 3-way V050C31ZLNV21 1/2 4.9 (4.3) / psi (0-862 kpa) 1.5 (1.3) / 111 V075T22ZLNV21 3/4" 2 way V075C22ZLNV21 V075T31ZLNV21 3/4" 3-way V075C31ZLNV21 3/ (8.9) / psi (0-862 kpa) 3.3 (2.8) / 82 V100T22ZLNV21 1" V100C22ZLNV21 Consult factory for additional model numbers *t 4 per second (Max. recommended residential flow rate). V100T31ZLNV21 1" 3-way V100C31ZLNV (7.7) / psi (0-862 kpa) 3.0 (2.6) / 411

6 The Taco Zone Sentry Zone Valve leads the industry in energy efficiency, flow capacity (Cv), shutoff pressure rating, ease of installation, diagnostic capability and the number of valves (12) that can be use on a standard 40V transformer. Taco Zone Sentry zone valves are available variety of configurations. ase of Installation / Operation: The Zone Sentry is the most technologically advanced zone valve ever made. It s also simple to install and operate. The valve can be installed in any direction, in any orientation except for chilled water installations (see igure ). urthermore, the actuator can be mounted to the valve body in either direction (see igure ). efore installing the valve body please note removal clearances (see igure C). Snap-in quick connects on the back of the valve make for a simple, secure and fast wiring hook-up. green LD light shows full functionality of the valve s operation and thermostat status. Under a no power situation the manual override button located on the top of the valve allows the ball to be rotated up to 90 and is also marked with a slot to indicate the position of the valve. igure 85 igure C 85 igure Two Position ead Placement. Universal ody Placement. May be installed in any position, any orientation. Permitted ngle of Installation on Chilled Water pplications W L L 3/4 clearance 1 3/8 clearance Taco Inc., 1160 Cranston Street, Cranston, RI / (401) / ax (401) Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) / ax (905)

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

Hydronic Mechanical Panels

Hydronic Mechanical Panels Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.

More information

Domestic Hot Water Systems and Plumbing Products

Domestic Hot Water Systems and Plumbing Products Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco

More information

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed Plumbing ECM High-Efficiency Hot Water Recirculation System Enjoy instant hot water comfort while avoiding a major renovation. The Hot-LinkPlus-e system installs easily into existing plumbing with a tank

More information

The smart way to instant hot water comfort.

The smart way to instant hot water comfort. The smart way to instant hot water comfort. Patent# US 8, 594, 853 B Taco Catalog # 100-97 Supersedes: 10/0/15 Effective Date: 03/31/17 Printed in USA The Problem: Waiting for Hot Water It s a common problem:

More information

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends P2050005, 1/2, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating

More information

HYDRONIC COMPONENTS & SYSTEMS

HYDRONIC COMPONENTS & SYSTEMS Fittings Twin Tee The Taco LoadMatch Twin Tee insures the comfort and performance of LoadMatch single pipe hydronic systems and primary secondary two pipe hydronic systems. HYDRONIC COMPONENTS & SYSTEMS

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Heat Pumps COMFORT NEED IT. When You

Heat Pumps COMFORT NEED IT. When You Heat Pumps COMFORT When You NEED IT COMFORT When You NEED IT SpacePak s Solstice heat pumps are air-to-water reverse cycle heat pumps that use the comfort of Hydronics as the primary source for both heating

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 10/22/14 Effective Date: 12/29/14 Printed in

More information

2.A MANIFOLD SHUNTS MINI SHUNTS

2.A MANIFOLD SHUNTS MINI SHUNTS 2.A MANIFOLD SHUNTS MINI SHUNTS ROTH HEATING SYSTEMS 2A. MANIFOLD SHUNTS Roth Manifold Shunts 4"/5.8cv and 1"/7.0cv Preassembled, manually adjusted, proportional temperature mixing station with built-in,

More information

Honeywell Water Solutions. Thermostatic Mixing Valves

Honeywell Water Solutions. Thermostatic Mixing Valves Honeywell Water Solutions Thermostatic Mixing Valves AMX300 Thermostatic Mixing Valve Kit Key Features and Benefits Kit includes mixing valve, cold water tee, flexible 8" or 11" metal connectors, and thermostrip

More information

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA TankMixer water heater tank mixing valve 520 series CLEFFI 01267/17 N CCREDITED ISO 9001 FM 21654 ISO 9001 No. 000 Function The Caleffi TankMixer 520_X series kit combines a three-way thermostatic mixing

More information

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing

More information

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco International Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco Catalog # : 300-6.0 Supersedes: 300-3.5 9/11/06 Effective Date: 03/21/07 Printed in USA Pumps FI Frame Mounted

More information

Instruction Sheet 00 Variable Speed Delta T (00-VDT)

Instruction Sheet 00 Variable Speed Delta T (00-VDT) Instruction Sheet 00 Variable Speed Delta T (00-VDT) 102-359 SUPERSEDES: January 1, 2010 EFFECTIVE: May 1, 2010 Plant ID# 001-3927 The Variable Speed Delta T 00 Cartridge Circulator (00-VDT) is a microprocessor-based

More information

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA Thermostatic mixing valves, low-lead, high-flow 5 series CCREDITED ISO 9 FM 5 ISO 9 No. CLEFFI 5/ N Replaces 5/5 N Function The thermostatic mixing valve is used in systems producing domestic hot water

More information

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA Instruction Sheet PC2 1 Two Stage Reset & Control SUPERSEDES : 102-106, dated June 1, 2000 EFFECTIVE: March 1, 2004 Plant ID# 9300-1059 Item 102-106 The PC2-1 is a microprocessor-based control designed

More information

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Adjustable three-way thermostatic mixing valve... connections ½, ¾, 1 NPT male union and sweat union and ¾ press MixCal djustable three-way thermostatic mixing valve series CCRIT ISO 9 FM ISO 9 No. CLFFI / N Replaces / N Function The Caleffi MixCal series three-way thermostatic mixing valve is used in systems producing

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

EXTROL EXPANSION TANKS

EXTROL EXPANSION TANKS EXTROL EXPANSION TANKS For Closed Hydronic Heating & Chilled Water Systems MADE IN USA SINCE 954 AMTROL Quality Expansion Tanks Table of Contents AMTROL Quality Expansion Tanks... 2 How It Works... 2 The

More information

STEAM ANGLE RADIATOR VALVE HOT WATER ANGLE VALVES DIMENSIONS IN INCHES DIMENSIONS IN INCHES

STEAM ANGLE RADIATOR VALVE HOT WATER ANGLE VALVES DIMENSIONS IN INCHES DIMENSIONS IN INCHES NGLE RDITOR VLVE ST OR T-431 LEGEND T-431 steam angle radiator valves are constructed of heavy duty bronze. They have a screwed bonnet, rising stem and composition disc. LEGEND T-431Y (Yellow rass) is

More information

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F 34-200 SERIES HYDRONIC TEMPERING VALVES The Apollo Model TV (34-200 Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic

More information

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

function Adjustable thee-way thermostatic mixing valve... connections 1/2, 3/4, 1 NPT male union and sweat union mixcal adjustable three-way thermostatic mixing valve series CCREITE ISO 9 FM ISO 9 No. CLEFFI / N Replaces / N LOW LE function The Caleffi MixCal three-way thermostatic mixing valve is used in systems

More information

Radiant Mixing Block

Radiant Mixing Block EFFECTIVE: arch 1, 2004 Taco Radiant ade Easy Application Guide Radiant ixing Block Products & Applications PA09 SUPERSEDES: New OVERVIEW Radiant ixing Block The Taco Radiant ixing Block (RB) is a complete

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-284. Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-284. Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers Series PSE-800 Probe Type Low Water Cut-Off for Steam Boilers McDonnell & Miller Installation & Maintenance Instructions MM-284 U.S. Patents 7,161,492 & 7,436,187 pplications: Residential and Commercial!

More information

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

Series 1156F, 1450F ( 1 2) Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers Used on boiler feed lines to provide make up water to the system Highest capacity performance Unique unitized

More information

Dynamic thermostatic radiator valves DYNAMICAL

Dynamic thermostatic radiator valves DYNAMICAL ynamic thermostatic radiator valves YNMIL -----7 series RIT ISO 9 M 6 /7 G unction The YNMIL valve allows the automatic dynamic balancing and pressure-independent adjustment of the thermal medium in the

More information

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA Electro-HELPS XV Made in USA ELECTRO-BOILER SPECIFICATIONS A complete product line to fi t all your application needs The Electro-Boiler has been heating America s homes and businesses since 980. We take

More information

Family of Circulators

Family of Circulators Water Circulation Pumps & Circulators Family of Circulators Taco LoadMatch series circulators are designed for quiet, efficient operation on LoadMatch fan coil heating & cooling systems. Each circulator

More information

Product Bulletin. Zenith Controls. Automatic Transfer Switch. ZTG Series. Fully Approved. Design and Construction Features

Product Bulletin. Zenith Controls. Automatic Transfer Switch. ZTG Series. Fully Approved. Design and Construction Features e G Zenith Controls Product ulletin ZTG Series utomatic Transfer Switch LD/LCD indicators for ease of viewing and long life Nonvolatile memory clock battery backup not required for standard switch operation

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

5231 Series.   Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341 NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

hydronic S Y S T E M S & C O M P O N E N T S

hydronic S Y S T E M S & C O M P O N E N T S hydronic S Y S T E M S & C O M P O N E N T S 4 A message from John Hazen White, Jr. For over 85 years, Taco has never strayed from its founding mission to provide you with the most reliable, easy to install

More information

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element Indirect Tanks for Domestic Hot Water New! Single coil tanks with electric element DHW Tanks FOR ALL SOLAR, GEOTHERMAL OR HYDRONIC APPLICATIONS LIMITED LIFETIME W A R R A N T Y Heavy Gauge Steel With Porcelain

More information

Variable Speed Outdoor Reset 00 Circulator (00-VR)

Variable Speed Outdoor Reset 00 Circulator (00-VR) Taco Radiant ade Easy Application Guide Variable Speed Reset 00 Circulator () EFFECTIVE: arch, 2004 Products & Applications PA03 SUPERSEDES: New OVERVIEW Variable Speed Reset 00 Circulator () The is a

More information

Astro 2 circulator models. Installation and operating instructions

Astro 2 circulator models. Installation and operating instructions Astro 2 circulator models Installation and File No: 10.89 Date: august 05, 2013 Supersedes: 10.89 Date: june 26, 2013 contents 1.0 Introduction 4 2.0 Installing 4 2.1 Terminal box 4 2.2 Electrical wiring

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS MODEL IHR MODEL OHP MODEL IPT 9-123.2 SEPTEMBER, 2016 9-123.2 FEATURES AND BENEFITS - MODEL IHR Figure 4.1 - Construction Features - Model IHR Features

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0

More information

Heating Systems Company LAARS INTRODUCES. The MASCOT LX. A Boiler. An All-in-One Answer to Your Home Heating and Hot Water Needs

Heating Systems Company LAARS INTRODUCES. The MASCOT LX. A Boiler. An All-in-One Answer to Your Home Heating and Hot Water Needs LAARS Systems Company INTRODUCES The MASCOT LX A Boiler. A Tankless Water Heater. A Money and Energy Saver. A WallHung Space Saver. A Full Family of Sizes. An AllinOne Answer to Your Home and Hot Water

More information

Nordic Heat Pump Product Guide

Nordic Heat Pump Product Guide Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal has been manufacturing the Nordic line of geothermal and air source heat pumps for over 30 years. We re committed to manufacturing

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

Quick response concealed horizontal sidewall sprinkler VK481

Quick response concealed horizontal sidewall sprinkler VK481 February 3, 2012 Sprinkler 63h 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK481 is a small solder link and lever spray sprinkler designed for installation on concealed

More information

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) THE HEATING BOX Training Manual Model KD-HBO100 & KD-HBC100 * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) Automatic Hot Water Management System A Combination System for Domestic Water and

More information

GRUNDFOS PLUMBING & HVAC PRODUCTS

GRUNDFOS PLUMBING & HVAC PRODUCTS GRUNDFOS PLUMBING & HVAC PRODUCTS SERIES UP CIRCULATORS GRUNDFOS CIRCULATORS FOR HEATING AND HOT WATER RECIRCULATION Quiet, maintenance-free performance Stainless steel construction, corrosion resistant

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation

More information

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler WTER HETING / OILERS CWMV PRODUCT SPECIFICTIONS Residential Hot Water Heat ir Handler ulletin No. 0434 ugust 05 Supersedes June 04 Heating Capacity - 3,700 to 0,000 tuh Nominal dd-on Cooling - to 5 Tons

More information

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators Instruction Sheet Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators 102-358 SUPERSEDES: May 1, 2010 EFFECTIVE: October 1, 2010 Plant ID# 001-3921 The Variable Speed - Setpoint 00 Cartridge

More information

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit series cert. n ISO / GB Function The modulating temperature regulating unit with high temperature distribution

More information

Table of Contents. 2 - JTG Muir - Taco Catalog

Table of Contents. 2 - JTG Muir - Taco Catalog Table of Contents Table of Contents 2 3-Speed 00-Series Circulators 3 00 Series Cartridge Circulators 4 Taco 00 Wet Rotor Circulator Cross Reference 5 Variable Speed Delta & 00 Circulators 7 Priority Zoning

More information

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers SUPERSEDES: Revision F Dated December 17, 2012 #5401179-REV G PLANT ID 001-3907 Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers Listings/Approvals EFFECTIVE: June1, 2017 102-338 UL GUIDE

More information

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION CONVECTION HEATING AND COOLING UNITS PART 1 GENERAL 1.01 SECTION INCLUDES A. Baseboard radiation. B. Finned tube radiation. C. Convectors. D. Unit heaters. E. Cabinet unit heaters. F. Fan-coil units. G. Unit ventilators. H. Blower-coil units.

More information

Installation and operating instructions. E.2 Series high efficiency circulator

Installation and operating instructions. E.2 Series high efficiency circulator Installation and operating instructions E.2 Series high efficiency circulator File No: 10.84 Date: august 16, 2012 Supersedes: 10.84 Date: july 20, 2010 contents 1.0 Operating limits 4 2.0 Electrical

More information

Hydronic Air Handler Powered by Tankless Technology

Hydronic Air Handler Powered by Tankless Technology Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RHWB- Series Nominal Heating Capacities: 32-90 kbtu [9.38-26.39 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in

More information

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator Instruction Sheet Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator The Variable Speed - Outdoor Reset 00 Cartridge Circulator (00-VR) is a microprocessor-based pump designed to regulate the

More information

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc) onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

5231 Series.  Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341. NA3. www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 5 Caleffi Installation, commissioning and service instructions Function 53 Series ASSE 7 model 53 series high fl ow thermostatic

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

THERMAL EXPANSION ABSORBERS

THERMAL EXPANSION ABSORBERS THERM-X-TROL THERML EXPNSION SORERS The est Solution for Controlling Thermal Expansion THERM-X-TROL Expansion Tanks Table of Contents THERM-X-TROL Expansion Tanks... 2 What is Thermal Expansion?... 2 THERM-X-TROL:

More information

Instruction Sheet RMB - Radiant Mixing Block

Instruction Sheet RMB - Radiant Mixing Block R Instruction Sheet RMB - Radiant Mixing Block 02-5 SUPERSEDES: July, 200 EECTIVE: October, 200 Plant ID#: 00-3807 WARNING SYMBOL: THIS SYMBOL INDICATES THE PRESENCE O HAZARDS WHICH CAN CAUSE SEVERE PERSONAL

More information

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING! Application Legend thermostatic mixing valves are designed for applications requiring temperature control, scald prevention and reduction of thermal shock in domestic potable water distribution (Model

More information

IMC-400A. Product Catalog. Engine Heaters Oil Heaters Controls Accessories

IMC-400A. Product Catalog. Engine Heaters Oil Heaters Controls Accessories IMC-400 Product Catalog Engine Heaters Oil Heaters Controls ccessories Section Four attery Pads attery Wraps Single or Multiple pplications Silicone Hot Pads 35 attery Heating Pads fully charged battery

More information

NOTES FOR AIR HANDLER APPLICATION:

NOTES FOR AIR HANDLER APPLICATION: 19 H. PIPING DIAGRAMS Figure 5 Phoenix Model With Air Handler - 5. Check with air handler manufacturer for proper sizing. 6. This drawing is meant to demonstrate system piping only. The installer is responsible

More information

Hydronic Air Handler Powered by Tankless Technology

Hydronic Air Handler Powered by Tankless Technology Integrated Solutions Hydronic Air Handler Powered by Tankless Technology RW1P/RW1T- Series Nominal Heating Capacities: 40-100 kbtu [11.7-29.3 kw] Tankless Water Heater Models: RTG-64DVL indoor direct vent

More information

water source / fan coils

water source / fan coils MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: Brute NEOTHERM Date: Project #: Hydronic Boiler Hydronic Boiler Indoor Sizes 285-850 Submittal Data Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Electronic PID

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D Technical Data SD 9902D SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 79902D/9803 Condensate Commander Pump Dimensions Weight Size A B C D E* F Lbs. 1"x

More information

Centro-Matic Automated Lubrication Systems System Controls

Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Tube Clamp Submittal Information Revision A: July 25, 2013

Tube Clamp Submittal Information Revision A: July 25, 2013 Tube Clamp Revision A: July 25, 2013 Polypropylene (PP) Tube Clamps secure ½" and ¾" Uponor crosslinked polyethylene (PEX-a) tubing products. Suspension Standard Description Part Number A B C Weight Tube

More information

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL HOMEADVANTAGE II HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical

More information

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps Water Circulation Pumps & Circulators GT Series Single-Stage, Double Suction Horizontal Split Case Pumps GT Series Pumps provide the ultimate in reliability and ease of installation for heating, air conditioning,

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Standard Features. Performance/Capacities

Standard Features. Performance/Capacities TSC-66 Traditional Power/Connections Approximate Total Load AMPS 208V / 60HZ / 3PH 51.8 208V / 60HZ / 1PH 88.3 230V / 60HZ / 3PH 47.8 230V / 60HZ / 1PH 81.5 460V / 60HZ / 3PH 23.9 Booster Heater Options

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

LAARS-STOR SERIES. Indirect Water Heaters

LAARS-STOR SERIES. Indirect Water Heaters LRS-STOR SRIS Indirect Water Heaters LRS-STOR SRIS Indirect Water Heaters Laars Heating Systems offers high volume single-wall and double-wall indirect water heaters. ll model types feature a super-efficient

More information

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS Copyright 2011. R. Trethewey, All rights reserved. No part of this document or file may be used without permission of the author. All diagrams are conceptual

More information

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076 GENERAL PRODUCT GUIDE 08 Quick Reference Air and dirt separators (DiscalDirt) Air separator (Discal brass) 9 Air separator (Discal Compact) 8 Air separator (Discal steel) 0 Air separator parts 8 Air vent,

More information

Standard Spray concealed horizontal sidewall sprinkler VK481

Standard Spray concealed horizontal sidewall sprinkler VK481 Page 1 of 6 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall VK481 is a small solder link and lever spray sprinkler designed for installation on concealed pipe systems. The sprinkler

More information

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE

More information

BLAZE 400G TURBO & BLAZE 600D TURBO I & Input BTU/h: 399,000 (400G), 575,000 (600GT & 600GTII) Indirect NG/LP Beckett Burner

BLAZE 400G TURBO & BLAZE 600D TURBO I & Input BTU/h: 399,000 (400G), 575,000 (600GT & 600GTII) Indirect NG/LP Beckett Burner CAMPO EQUIPMENT 6 Carson Court, Brampton, ON, L6T 4P8 1-866-323-0042 www. campoequipment.com BLAZE 400D TURBO Input BTU/h: 280,000 to 396,000 Indirect Oil Fired Beckett Burner (4 Firing Rates) 220 F +

More information

Control Panel Checklist

Control Panel Checklist Control Panel Checklist Versatronik -C Panel Checklist Option Selection for Control Panel Quotes Checklist Control Panel Checklist Section 1 General Information Customer name Phone number Fax number Email

More information

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T www.caleffi.com 37. MixCal adjustable three-way thermostatic mixing valve Copyright Caleffi Installation, commissioning and servicing instructions Series Function The Caleffi MixCal three-way thermostatic

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE March 2, 2007 Sprinkler 147k 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK425 is small a highsensitivity solder link and lever residential sprinkler designed for installation

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always

More information

1900 Series In-Line Pump

1900 Series In-Line Pump Water Circulation Pumps & Circulators 1900 Series In-Line Pump HYDRONIC COMPONENTS & SYSTEMS Taco Catalog #: 300-1.4 Supersedes: 300-1.4 Dated: 06/15/95 Effective Date: 03/15/05 Printed in USA 2. Features

More information

Model 7949/ES Air Supply Exhaust Muffler. System Function

Model 7949/ES Air Supply Exhaust Muffler. System Function *19282* 19282 Blow-pen Control Box Model 7949/ES 7949 Installation Instructions For uto-equalizer & Regular Control Box information, see installation instruction sheets packed with those products. LL NTE:

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

ProRadiant Manifolds, Stations and Fittings

ProRadiant Manifolds, Stations and Fittings Manifolds, Stations and Fittgs 197 Staless Manifolds and Accessories # of Outlets STAINLESS MANIFOLD - SHUT-OFF / BALANCING / FLOW METERS These preassembled 1-1/4" diameter staless supply and return manifolds

More information

SCREW COMPRESSORS - ELECTRIC

SCREW COMPRESSORS - ELECTRIC SERIES RS - ROTOR SCREW The Pneutech Rotor Screw unit is directly coupled to the electric motor, which gives an efficient 100% power transfer for optimum performances and low running costs. With fewer

More information

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...

More information

E.2 series high efficiency circulator. Installation and operating instructions

E.2 series high efficiency circulator. Installation and operating instructions E.2 series high efficiency circulator Installation and operating instructions File No: 10.84 Date: august 16, 2012 Supersedes: 10.84 Date: july 20, 2010 contents 1.0 Operating limits 4 2.0 Electrical

More information

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E PRODUCT SPECIFICATIONS Gas-Fired Hot Water Boiler Bulletin No. 065 September 0 Supersedes Bulletin No. 06 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Boiler & Water Heater

Boiler & Water Heater MIGHTY THERM2 Date: Project #: Pump-Mounted Boiler & Water Heater MT2H Hydronic Heater MT2V Volume Water Heater Indoor/Outdoor Sizes 500-2000 Submittal Engineer: Project Name: Prepared By: Location: Bid

More information

T. +44 (0) E.

T. +44 (0) E. Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot

More information