1 Manifolds, Stations and Fittgs 197

2 Staless Manifolds and Accessories # of Outlets STAINLESS MANIFOLD - SHUT-OFF / BALANCING / FLOW METERS These preassembled 1-1/4" diameter staless supply and return manifolds come attached to two -5/8" spacg brackets for compact remote mountg. This staless manifold provides shut off and balancg valves with flow meters for each set of circuits. Manifold is used with flow rates up to 2 GPM per circuit with a maximum of 18 GPM. The air bleeders and purge valves are connected and factory tested. 1-1/4" Union connection, 1" NPT removable end caps. Circuit connection fittgs are sold separately. model # of Outlets STAINLESS MANIFOLD - SHUT-OFF / BALANCING These preassembled 1-1/4" diameter staless supply and return manifolds come attached to two -5/8" spacg brackets for compact remote mountg. This staless manifold provides shut off and balancg valves for each circuit. Manifold is used with flow rates up to 2 GPM per circuit with a maximum of 18 GPM. The air bleeders and purge valves are connected and factory tested. 1-1/4" Union connection, 1" NPT removable end caps. Circuit connection fittgs are sold separately. model # of Outlets STAINLESS MANIFOLD - VALVELESS These preassembled 1-1/4" diameter staless supply and return manifolds come attached to two -5/8" spacg brackets for compact remote mountg. Manifold is used with flow rates up to 2 GPM per circuit with a maximum of 18 GPM. The air bleeders and purge valves are connected and factory tested. 1-1/4" Union connection, 1" NPT removable end caps. Circuit connection fittgs are sold separately. model STAINLESS MANIFOLD BALL VALVE SET Use staless manifold ball valve set to isolate staless manifold from existg pipg. model Union x F NPT /4 x

3 STAINLESS MANIFOLD EXPANSION SET - SHUT-OFF / BALANCING These staless manifold extensions attach to staless manifolds to add circuits. Expansion set comes with balancg valve on supply and shut off valve on return manifold. 1-1/4" M NPT x 1" M NPT adapter cluded set. model STAINLESS MANIFOLD EXPANSION SET - SHUT-OFF / BALANCING / FLOW METER These staless manifold extensions attach to staless manifolds to add circuits. Expansion set comes with balancg valve/flow meter on supply and shut off valve on return manifold. 1-1/4" M NPT x 1" M NPT adapter cluded set. model EXPANSION NIPPLE Adapters to connect staless manifolds. model /4 x STAINLESS MANIFOLD OUTLET CAPS Use these caps to seal extra outlets on Staless Steel Manifolds. model SVC REDUCERS 1-1/4" to 1" NPT reducers are used to connect Staless Manifolds to Mixg Stations and Injection Stations. model SV M NPT x F NPT /4 x

4 STAINLESS MANIFOLD END PLUGS These plugs are used to seal the ends of the Staless Steel Manifolds. model AUTOMATIC AIR VENT Automatic air vent can be used as an alternative for air bleeder on staless manifolds. Air vent should be mounted on the supply header. model / CIRCUIT TEMPERATURE GAUGE SET This mi temperature gauge snaps on return side of Staless Manifold Shut-Off / Balancg / Flow Meter. Gauge reads return temperature of dividual circuits. model SYSTEM PRESSURIZATION KIT Pressurization kit for Viega stations or manifolds. Connects to purge valve or SVC fittg. Two 1-1/4" M NPT x 1" F NPT reducers and two 1" NPT plugs cluded for testg remote manifolds. Gauge reads psi. model US SVC CIRCUIT BALL VALVE Attach to valve seats on manifolds to provide dividual circuit shut-off capability. Useful for purgg one circuit at a time, or for circuit shutoff on 1-1/2" brass manifolds and staless manifold valveless. model 1024SV

5 PEX Press x SVC SVC PRESS ADAPTER These adapters allow the Viega PEX Press connection system to be used on manifolds or other SVC connection components. model 2819NG /1 5 3/8 5 1/2 5 5/8 5 3/ SVC COMPRESSION PEX ADAPTER These compression fittgs attach ViegaPEX tubg to Viega manifolds, SVC x M NPT and SVC couplgs. model 1022SV /1 2 3/8 2 1/2 2 5/8 2 3/ SVC COMPRESSION COPPER ADAPTER Compression fittgs connect copper tubg to SVC seat without solderg. Compression fittgs are compatible with type K, L and M copper tubg only. model SV /0 3/ SVC MALE NPT ADAPTER These fittgs adapt any SVC adapters to a male NPT fittg. model 1022.SV /2 5 3/ SVC COUPLING Accepts all SVC system adapters to couple tubg of the same or different sizes. model SV

6 COMPRESSION COUPLING 5/1" Low profile compression couplg for 5/1" tubg, specifically for Climate Panel tubg repairs. model 1030SV / SVC COMPRESSION COUPLING SVC Compression Couplgs allow easy repair of damaged tubg or connection of splices. Each cludes SVC couplg and two PEX adapters. model SV /8 1 1/ 5/8 1 3/ STRAP ON TEMPERATURE GAUGE SET Easy to read 2-1/2" diameter temperature gauge straps onto copper pipg with cluded sprg, or can be soldered. Gauge reads F. Heat transfer paste cluded. model US

7 Header x Circuit Connection - Outlets COPPER MANIFOLD, SHUT-OFF VALVES Commonly used commercial heatg, coolg and snow-ice meltg applications. These Shut-Off Valve Copper Manifolds are available 1-1/2" and 2" configurations. Copper Manifolds with Shut-Off Valves are Viega PEX Press connection type only. Made of Type L copper. 1-1/2" and 2" Copper Manifolds are designed to utilize Viega s ProPress fittgs to connect to boiler loop. Recommended max. flow rate of 1-1/2" Copper Manifolds is 32 gpm. Recommended max. flow rate of 2" Copper Manifolds is 45 gpm. model 2834US /2 x 5/ /2 x 3/4-1 2 x 5/8-1 2 x 3/ Header x Circuit Connection - Outlets COPPER MANIFOLD, SHUT-OFF / BALANCING VALVES Commonly used commercial heatg, coolg and snow-ice meltg applications. These Shut-Off / Balancg Valve Copper Manifolds are available 1-1/2" and 2" configurations. Copper Manifolds with Shut-Off / Balancg Valves are Viega PEX Press connection type only. Made of Type L copper. 1-1/2" and 2" Copper Manifolds are designed to utilize Viega s ProPress fittgs to connect to boiler loop. Recommended max. flow rate of 1-1/2" Copper Manifolds is 32 gpm. Recommended max. flow rate of 2" Copper Manifolds is 45 gpm. model US /2 x 5/ /2 x 3/4-1 2 x 5/8-1 2 x 3/ Header x Circuit Connection - Outlets COPPER MANIFOLD, VALVELESS Commonly used commercial heatg, coolg and snow-ice meltg applications. These Valveless Copper Manifolds are available 1", 1-1/2" and 2" configurations. Made of Type L copper. 1-1/2" and 2" Copper Manifolds are designed to utilize Viega s ProPress fittgs to connect to boiler loop. 1" Copper Manifolds are either copper male or copper female for solder connections to boiler loop. Recommended max. flow rate for 1" Copper Manifolds is 13 gpm. Recommended max. flow rate of 1-1/2" Copper Manifolds is 32 gpm. Recommended max. flow rate of 2" Copper Manifolds is 45 gpm. model 2835US x 1/ x 1/ x 1/ x 1/ /2 x 3/ x 3/

8 PEX Press PEX PRESS SLEEVES These staless steel sleeves provide a secure press fit for the Viega PEX Press system. The view hole can be used to verify full tubg sertion. Use only with Viega PEX Press fittgs and tools. model / /00 5/ / / / Copper x PEX Press SHUT-OFF VALVE These Shut-Off Valves are available Copper (female) x Viega PEX Press. These Shut-Off Valves can be used to connect radiant heatg and / or coolg PEX tubg to Viega Valveless Copper Manifolds, or other copper x PEX Press connections. model US /2 x 1/0 3/4 x 5/8 10 3/4 x 3/ Copper x PEX Press SHUT-OFF / BALANCING VALVE These Shut-Off / Balancg Valves are available Copper (female) x Viega PEX Press only. These Shut-Off / Balancg Valves can be used to connect radiant heatg and / or coolg PEX tubg to Viega Valveless Copper Manifolds, or other copper x PEX Press connections. model US /2 x 1/0 3/4 x 5/8 10 3/4 x 3/ Copper x PEX Compression SHUT-OFF VALVE These Shut-Off Valves are available Copper (female) x Compression. These Shut-Off Valves can be used to connect radiant heatg and / or coolg PEX tubg to Viega Valveless Copper Manifolds, or other copper x PEX Compression connections. model US /2 x 1/0 3/4 x 5/ COPPER MANIFOLD END CAPS Copper Manifold End Caps have two F NPT adapters, one is 1/2" for a draw-off (purge valve). The other is 1/8" for an automatic air vent (bottle vent). Made of Type L copper. model US /

9 COPPER MANIFOLD BRACKETS The Copper Manifold Brackets simplify stallation and are designed to give the proper offset between the supply and return header. model / 205

10 ProBloc The Viega ProBloc provides a mixed system supply water temperature that is modulated by a built mixg valve and actuator. With an easy flip of a dip switch to "ProBloc" on the front display of the Basic Heatg Control, all control settgs e.g. actuator speed will default to ProBloc. ProBlocs are available with two 3- speed circulator pump options, either high or low head. Boiler loop connections can be made with a variety of fittgs: ProPress, PEX Press or F NPT adapters. To connect to a nearby staless manifold use the new Staless Manifold Connections Set. Additional Features: Built pressure differential valve Circulator Pump with built- check valve Simple bracket stallation to mount ProBloc Shut-Off valves with built- temperature gauges on supply and return Installation template cludg wirg to Basic Heatg Control Modern sulated enclosure design model Low Head 3-Speed Circulator 1 High Head 3-Speed Circulator 1 Staless Manifold Connection Set Use this Staless Manifold Connection Set to hook up a staless manifold directly to the ProBloc. BA = ProBloc outlet connection SMA = Staless Manifold model BA x SMA /2 x 1 1/ ProBloc Adapter ProPress These adapters are designed to connect to any let or outlet of the ProBloc. model BA x P /2 x BA x PEX Press ProBloc Adapter These adapters are disigned to connect to any let or outlet of the ProBloc. model NG /2 x /2 x 1 1/

11 ProBloc Adapter These adapters are disigned to connect to any let or outlet of the ProBloc. model BA x F NPT /2 x P x P x P ProBloc Primary Loop Double Tee The spacg of this Primary Loop Double Tee matches the let and outlet connections of the ProBloc. model x 1 x /4 x 1 1/4 x

12 Assembled Mixg Station order configuration specification examples ASSEMBLED MIXING STATIONS WITH STAINLESS MANIFOLD SHUT-OFF / BALANCING / FLOW METERS The Viega Assembled Mixg Station is shipped ready to hang on the wall. The Staless Manifold Shut-Off / Balancg / Flow meters is available with compression (COM), press (PRS) or copper compressiom (COP) adapters. Boiler or primary loop connections can be made with ProPress (PPS), PEX Press (PRS) or copper (male) (COP). Station comes preassembled and factory tested. Boiler feed, tubg direction, tubg size and circuit connection must be specified - see orderg example below. CONFIGURATIONS TL (Top Left Configuration) TR (Top Right Configuration) When orderg, specify: STOCK CONFIGURATIONS TUBING CIRCUIT BOILER CODE SIZE CONNECTION ADAPTER Example: BR-1/2-PRS-PPS code Bottom tubg, 1/2" tubg Press Circuit Right boiler feed Connection (Configuration) Boiler Adapter BL (Bottom Left Configuration) BR (Bottom Right Configuration) Circulator Low Head 3-Speed High Head 3-Speed Outlets Mixg Station 2 outlets Mixg Station 3 outlets Mixg Station 4 outlets Mixg Station 5 outlets Mixg Station outlets Mixg Station 7 outlets Mixg Station 8 outlets Mixg Station 9 outlets Mixg Station 10 outlets Mixg Station 11 outlets Mixg Station 12 outlets

13 BASE MIXING STATIONS The new Viega Mixg Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensg boilers, water heaters, or geothermal heat pumps. Stations are now available with 3 speed circulator pumps either high or low head. Boiler connections can be made with ProPress, PEX Press Adapters or Copper (male) for solderg. Red and blue caps on the ProPress Ball Valves clearly dicate system supply and return connections. A built sensor well allows easy mountg of the supply temperature sensor for either the Basic Heatg Control or Advanced Heatg Control. HIGH HEAD model US ProPress 1 PEX Press 1 Copper (male) LOW HEAD model US ProPress 1 PEX Press 1 Copper (male) outlets ASSEMBLED MIXING STATIONS WITH STAINLESS MANIFOLD - SHUT OFF / BALANCING / FLOW METERS The Viega Assembled Mixg Station is shipped ready to hang on the wall. The staless manifold - shut off / balancg / flow meters is available with compression (com), press (prs) or copper (cop) adapters. Station comes preassembled and factory tested. Boiler feed, tubg direction, tubg size and circuit connection must be specified. NOTE: Made to Order. Lead time apx. 10 workg days. LOW HEAD PUMP model US HIGH HEAD PUMP model US

14 outlets ASSEMBLED MIXING STATION WITH STAINLESS MANIFOLD - SHUT OFF / BALANCING The Viega Assembled Mixg Station is shipped ready to hang on the wall. Station comes preassembled and factory tested. code, tubg direction, boiler location, tubg size, circuit connection and boiler connection type must be specified - see orderg example below. NOTE: Made to Order. Lead time apx. 10 workg days. LOW HEAD PUMP model US HIGH HEAD PUMP model US

15 PEX Press Fittgs PEX Press x C BRONZE PEX PRESS PROPRESS ADAPTERS Use these adapters to transition directly from ViegaPEX or FostaPEX to copper tubg. Press fittgs make flameless plumbg and hydronic heatg connections fast and simple. The ProPress tool, available through Ridge Tool distribution, is required for the copper connection. ProPress is compatible with type K, L and M copper tubg only. model 2813PNG /2 x 1/2 5 1/2 x 3/4 5 5/8 x 1/2 5 5/8 x 3/4 5 3/4 x 1/2 5 3/4 x 3/4 5 1 x /4 x 1 1/ /2 x 1 1/ PEX Press x Copper (female) BRONZE PEX PRESS COPPER TUBING ADAPTERS Use copper tubg adapters to make a PEX Press connection between ViegaPEX or FostaPEX tubg and standard copper tubg. Adapters solder over copper tubg. model NG /8 x 1/2 5 1/2 x 1/2 5 1/2 x 3/4 5 5/8 x 1/2 5 5/8 x 3/4 5 3/4 x 1/2 5 3/4 x 3/4 5 3/4 x x /4 x 1 1/ /2 x 1 1/ PEX x Copper (male) BRONZE PEX PRESS COPPER FITTING ADAPTERS Use copper fittg adapters to make PEX Press connections between ViegaPEX or FostaPEX tubg and copper fittgs. Adapters fit to solder cup or ProPress fittgs. model NG /2 x 1/2 5 1/2 x 3/4 5 5/8 x 1/2 5 5/8 x 3/4 5 3/4 x 1/2 5 3/4 x 3/4 5 3/4 x x /4 x 1 1/ /2 x 1 1/ PEX x Copper BRONZE PEX PRESS COPPER TUBING ELBOWS 90 elbows connect ViegaPEX or FostaPEX tubg to copper tubg. Bronze PEX Press fittgs make baseboard and plumbg connections fast and simple. Sweat elbow fits over standard copper tubg or baseboard. BRONZE PEX PRESS FEMALE COPPER TUBING ELBOWS model NG /2 x 3/4 5 5/8 x 3/4 5 3/4 x 3/ Bronze Pex Press Male Copper Fittg Elbows model 2814.NG /2 x 1/ Bronze Pex Press Male or Female Copper Fittg or Tubg Elbows model NG /2 x 3/4 or 1/2 5 5/8 x 3/4 or 1/2 5 3/4 x 3/4 or 1/

16 PEX Press x PEX Press BRONZE PEX PRESS ELBOWS Use elbows for makg 90 PEX Press connections ViegaPEX or FostaPEX runs. model 281NG /2 5 5/8 5 3/ / / PEX Press x PEX Press x PEX Press BRONZE PEX PRESS TEES Use these PEX Press tees to jo ViegaPEX or FostaPEX tubg. Dimensions are listed as labeled, A x B x C. model 2818NG /2 5 1/2 x 3/8 x 3/8 5 1/2 x 1/2 x 3/4 5 5/8 5 3/4 5 3/4 x 1/2 x 1/2 5 3/4 x 1/2 x 3/4 5 3/4 x 3/4 x 1/ x 1/2 x 1/2 5 1 x 1/2 x x 3/4 x 1/2 5 1 x 3/4 x 3/4 5 1 x 3/4 x x 1 x 1/2 5 1 x 1 x 3/ / /4 x 1 x 3/ /4 x 1 x /4 x 1 1/4 x 3/ /4 x 1 1/4 x / /2 x 1 x 3/ /2 x 1 x /2 x 1 1/2 x 3/ /2 x 1 1/2 x /2 x 1 1/2 x 1 1/ PEX Press BRONZE PEX PRESS TEST PLUGS Use PEX Press plugs to cap ViegaPEX or FostaPEX tubg with a PEX Press connection for pressure testg or at dead ends. model 285NG /8 5 1/2 5 5/8 5 3/

17 PEX Press x M NPT BRONZE PEX PRESS MALE NPT ADAPTERS Use male adapters to make a PEX Press connection between ViegaPEX or FostaPEX tubg and a female NPT thread. model 2811NG /8 x 1/2 5 1/2 x 1/2 5 1/2 x 3/4 5 5/8 x 1/2 5 5/8 x 3/4 5 3/4 x 1/2 5 3/4 x 3/4 5 3/4 x 1 5 3/4 x 1 1/4 2 1 x 3/4 5 1 x x 1 1/ /4 x 1 1/ /2 x 1 1/ PEX Press x M NPT BRONZE PEX PRESS MALE NPT ELBOWS Use male NPT threaded elbows to make a 90º PEX Press connection between ViegaPEX or FostaPEX tubg and a female NPT thread. model 2814NG /2 x 1/2 5 1/2 x 3/4 5 3/4 x 3/4 5 3/4 x 1 5 3/4 x 1 1/4 2 1 x x 1 1/ /4 x 1 1/ PEX Press x F NPT BRONZE PEX PRESS FEMALE NPT ADAPTERS Use female adapters to make a PEX Press connection between ViegaPEX or FostaPEX tubg and a male NPT thread. model 2812NG /2 x 1/2 5 1/2 x 3/4 5 3/4 x 1/2 5 3/4 x 3/4 5 1 x 3/4 5 1 x PEX Press x PEX Press BRONZE PEX PRESS COUPLINGS Use these couplgs to connect two sections of ViegaPEX or FostaPEX tubg with the PEX Press connection. Use to repair damaged sections or connect long runs. model 2815NG /1 5 3/8 5 1/2 5 1/2 x 3/4 5 5/8 5 3/4 5 3/4 x 1 5 3/4 x 1 1/ x 1 1/4 5 1 x 1 1/ / /4 x 1 1/ / /2 x 3/

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 1 Annex G Standards. 11 PEX Manifold Plumbing Systems # of Outlets: Dimension (hot,cold) MANABLOC -BRONZE PEX PRESS

More information

ProRadiant Combiflex. Viega's Hydronic Solution Installation Manual 2013

ProRadiant Combiflex. Viega's Hydronic Solution Installation Manual 2013 ProRadiant Combiflex Viega's Hydronic Solution Installation Manual 2013 Contents 1 System Advantages and Benefits 1.1 Combiflex system concept...3 1.2 Application benefits...4 1.3 Manifold/mixing equipment

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

Zurn Hydronics Prices Effective 1/01/06

Zurn Hydronics Prices Effective 1/01/06 CURRENT MFG LIST Radiant Tubing / Manifolds / Tools Boxed Barrier Pex Tubing QUE/QHR2PC1000X 3/8" x 1000' Roll (Barrier) $1,085.45 QUE/QHR2PC500X 3/8" x 500' Roll (Barrier) $542.73 QUE/QHR4PC500X 3/4"

More information

HVAC No. MFG Part No. Description Size Price

HVAC No. MFG Part No. Description Size Price Circulator Isolation Flanges and Valves Webstone 113460 113462 113464 113466 390608 390564 Flanged Isolation Valves 110-251F 110-252F 110-253F 110-254F SF-075T SF-100T Freedom Flange, Cast Iron Freedom

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

New Products in this Catalog

New Products in this Catalog New Products in this Catalog X-PERT Tubing - pg. 4 3-way Mixing Valves - pg. 50 Crete-Heat Insulated Floor Panels - pg. 10 3 & 4-way Mixing Valve Actuators - pg. 50 Residential Copper Manifolds - pg. 22

More information

Settlement Agreement. Schedule 1: Covered Products

Settlement Agreement. Schedule 1: Covered Products Settlement Agreement Schedule 1: Covered Products COVERED PRODUCT BRANDS BRASSCRAFT PLUMBSHOP PEERLESS SOLUTIONS MASTER PLUMBER COVERED PRODUCT CATEGORIES - WATER SUPPLIES SUPPLY STOPS WATER SUPPLY CONNECTORS

More information

Hydronic Radiant and Snowmelt. Product Catalog. Living full of energy

Hydronic Radiant and Snowmelt. Product Catalog. Living full of energy Hydronic Radiant and Snowmelt Product Catalog Tubing Panel Systems Manifold and Mixing Stations Fittings and Tools Valves and Controls Living full of energy Hydronic and Radiant Heating Product Catalog

More information

Allcan TM Installation Manual

Allcan TM Installation Manual Allcan TM Installation Manual NOTICE: READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW INSTRUCTIONS VOIDS WARRANTY. Introduction: The PHP Allcan (USA patent pending) is a complete primary/secondary

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Hydronic Mechanical Panels

Hydronic Mechanical Panels Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.

More information

Tube Clamp Submittal Information Revision A: July 25, 2013

Tube Clamp Submittal Information Revision A: July 25, 2013 Tube Clamp Revision A: July 25, 2013 Polypropylene (PP) Tube Clamps secure ½" and ¾" Uponor crosslinked polyethylene (PEX-a) tubing products. Suspension Standard Description Part Number A B C Weight Tube

More information

Central Boiler. Heating Accessories and Parts Catalog

Central Boiler. Heating Accessories and Parts Catalog Central Boiler Heating Accessories and Parts Catalog To place an order use the dealer locator on our website: www.centralboiler.com or call for nearest dealer: 1-800-248-4681 or 218-782-2575 DIMENSIONS

More information

Viega ProRadiant Pocket Guide

Viega ProRadiant Pocket Guide Viega ProRadiant Pocket Guide The global leader in plumbing, heating and pipe joining systems Viega ProRadiant Pocket Guide Thank you for choosing Viega. Welcome! Viega s global legacy of excellence began

More information

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen Hydronic Mixing Block Version 1.104 The Hydronic Mixing Block is a mixing device and boiler control, with a built in circulator and system controller. The block can provide either a fixed or reset water

More information

ProRadiant Basic Heating Control Installation Manual 2013

ProRadiant Basic Heating Control Installation Manual 2013 ProRadiant Basic Heating Control Installation Manual 2013 The Viega Basic Heating Control is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset operation.

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

Viega Concrete System Installation Manual

Viega Concrete System Installation Manual Viega Concrete System Installation Manual The global leader in plumbing, heating and pipe joining systems Welcome By choosing to install a Viega Concrete System, you have joined the ranks of heating system

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING! Application Legend thermostatic mixing valves are designed for applications requiring temperature control, scald prevention and reduction of thermal shock in domestic potable water distribution (Model

More information

Water Piping and Pumps

Water Piping and Pumps Technical Development Program DISTRIBUTION SYSTEMS Water Piping and Pumps PRESENTED BY: Michael Ho carriertdp@gmail.com 424-262-2144 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel

More information

propanel Series Installation Manual

propanel Series Installation Manual propanel Series Installation Manual propanel Series Installation Manual is published by Uponor Wirsbo 5925 148th Street West Apple Valley, MN 55124 (952) 891-2000 2003 Uponor Wirsbo All rights reserved

More information

TECHNICAL. Series 18. Pump Packages

TECHNICAL. Series 18. Pump Packages TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump

More information

2.A MANIFOLD SHUNTS MINI SHUNTS

2.A MANIFOLD SHUNTS MINI SHUNTS 2.A MANIFOLD SHUNTS MINI SHUNTS ROTH HEATING SYSTEMS 2A. MANIFOLD SHUNTS Roth Manifold Shunts 4"/5.8cv and 1"/7.0cv Preassembled, manually adjusted, proportional temperature mixing station with built-in,

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION

PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION On Off Combine a forged brass manifold and components to streamline boiler and secondary loops installations. Eliminates costly field

More information

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F 34-200 SERIES HYDRONIC TEMPERING VALVES The Apollo Model TV (34-200 Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic

More information

Heat Link MECHANICAL ROOM IN A BOX. SSP Series SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x SSPLR106T SSPSS106B

Heat Link MECHANICAL ROOM IN A BOX. SSP Series SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x SSPLR106T SSPSS106B SSP Series SS Manifold Pump Panel Manual GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40 60 0 0 40 40 60 80 00 SSPLR06T GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water Packaged Instantaneous Domestic Hot Water Generator Energy Source: Shown with optional boiler water valve and electronic feed-forward control. Operates with low boiler water supply and return temperatures

More information

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T Heat Link SSP Series SS Manifold Pump Panel Manual NEUTRAL GROUND LIVE CAUTION 115 VOLTS ONLY SSPLR106T GROUND LIVE NEUTRAL CAUTION 115 VOLTS ONLY 120 40 60 60 80 100 C F 200 0 180 20 40 140 160 80 100

More information

MASCOT Quick Setup Guide

MASCOT Quick Setup Guide MASCOT Quick Setup Guide Minimum Gas Pipe Sizing Guide For Black Iron pipe Refer to Sizing charts for a complete system design Mascot Models Output btu Branch Gas Line HT 330/1.330 126,376 3/4" HT 1.450

More information

Viega ProPress Marine Systems Safe, secure connections across the seas.

Viega ProPress Marine Systems Safe, secure connections across the seas. Viega ProPress Marine Systems Safe, secure connections across the seas. Your connection to innovation Viega adds traps and draining products for sinks and bathtubs to our lineup. The first PEX radiant

More information

ECO1ZN3P, ECO2ZN4P ECO

ECO1ZN3P, ECO2ZN4P ECO WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN

More information

"Best Practices in Modern Hydronic Heating - THE DETAILS

Best Practices in Modern Hydronic Heating - THE DETAILS "Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r

More information

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the

More information

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER! 1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based

More information

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL FloorHeat PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL Thank you for purchasing this radiant control panel assembly. Following are some important notes that will make the installation successful.

More information

Potable Piping System

Potable Piping System Page, May 2006 Potable Piping System BOW SUPERPEX is designed with three distinct layers for ultimate protection. The middle layer provides chlorine resistance as well as UV light exposure resistance plus

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation

More information

PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION

PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION On Off Combine a forged brass manifold and components to streamline boiler and secondary loop installations. Eliminates costly field

More information

WAL-RICH CORPORATION SINCE 1950

WAL-RICH CORPORATION SINCE 1950 HOSES 3/8 ID DOUBLE FEMALE HOSE - BAGGED BAGGED# SIZE Box 0802002 3/4 FHT x 4' 1 25 0802004 3/4 FHT x 5' 1 25 0802006 3/4 FHT x 6' 1 25 0802008 3/4 FHT x 8' 1 25 0802010 3/4 FHT x 10' 1 25 0802012 3/4

More information

Viega Fire Sprinkler Systems

Viega Fire Sprinkler Systems Viega Fire Sprinkler Systems The global leader in plumbing, heating and pipe joining systems Viega adds traps and draining products for sinks and bathtubs to our lineup. The first PEX radiant floor heating

More information

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F UDX No Sweat Kit instuctions The No Sweat Kit is intended to be used in conjunction with the AET s DB-10-10XC and DB-15-15XC on a 120 or 80 gallon OST (American Water Heater) top or side connect tank.

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

EZ Plate Instantaneous

EZ Plate Instantaneous EZ Plate Instantaneous Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water PVI.com Packaged Instantaneous Domestic Hot Water EZ Plate Instantaneous is a factory-packaged, skid-mounted

More information

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing Mascot Gas-Fired Residential and Commercial Wall-Mounted Boiler Easy Installation, 96% Efficiency, Fully Condensing Mascot is a high-efficiency, wall-mounted boiler available in three BTU sizes 126, 167,

More information

Making Crimp Connections

Making Crimp Connections Making Crimp Connections Cut tube off square (90 ) with a tube cutter. Tube Cutter Slide the PEX crimp ring over the end end of the tube. BE SURE the crimp ring is centered over the PEX barb. Slide the

More information

LF Readout Displayed on LED. Compressor Stops Fan Runs. 1 Hour Time INFORMATION. Delay Activates

LF Readout Displayed on LED. Compressor Stops Fan Runs. 1 Hour Time INFORMATION. Delay Activates G. OPERATIONAL SEQUENCE & TROUBLESHOOTG CHART 220V Power To Heater Green Power Light On Possible Bad T-Stat Board, Pot or Sensor Heater Stays Off Water Pump Timer Activates T-Stat Relay Does Not Close

More information

Fundamentals of Hydronic Design

Fundamentals of Hydronic Design Radiant Based HVAC Systems Differential Pressure Fundamentals of Hydronic Design This educational material is copy written by Robert Bean, R.E.T., All Rights Reserved. If you wish to use this presentation

More information

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133. Main Steam How to Select Steam For Steam Vent selection information, please refer to Selection Guidelines on page 133. Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater

More information

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving, ahead just as planned. Manual: 2100-212A Supersedes: 2100-212 File: Tab 8

More information

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

hydronics WHAT S WRONG WITH THIS SCHEMATIC? BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

SHARKBITE CONNECTING SYSTEM

SHARKBITE CONNECTING SYSTEM INDEX CASH ACME valves with sharkbite connectors ball valves... 14-8 check valves... 14-8 connectors bullnose... 14-3 reducing... 14-3 straight... 14-3 couplings reducing... 14-2 straight... 14-2 elbows

More information

Radiant Pipe Description

Radiant Pipe Description Radiant Pipe Item Description ATIPXOB4C10 ATIPXOB4C250 ATIPXOB4C5 ATI Radiant Pex 1/2" x 1000' O2 barrier ATI Radiant Pex 1/2" x 250' with O2 barrier ATI Radiant Pex 1/2" x 500' with O2 barrier MPX836

More information

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076 GENERAL PRODUCT GUIDE 08 Quick Reference Air and dirt separators (DiscalDirt) Air separator (Discal brass) 9 Air separator (Discal Compact) 8 Air separator (Discal steel) 0 Air separator parts 8 Air vent,

More information

TA-Compact-P. Giving you MORE by giving you LESS

TA-Compact-P. Giving you MORE by giving you LESS TA-Compact-P Giving you MORE by giving you LESS control valve balancing valve 5 in 1 full measurement TA-Compact-P The new two-way pressure independent balancing and control valve for terminal units in

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

LGB Gas fired boiler

LGB Gas fired boiler LGB Gas fired boiler Control Supplement LGB-5 Series 2 Propane gas CSD-1 Control System Part Number 550-110-682/0304 Please read this page first Hazard definitions To the installer... The following terms

More information

Canadian Retail. Parts Catalogue

Canadian Retail. Parts Catalogue Canadian Retail Parts Catalogue 2017 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Water to Air Heat Exchangers / Water to Water Heat Exchangers Tube & Shell Heat Exchangers / Sidearm Exchangers / Grundfos Pumps Taco

More information

Marine Coolant Heater Catalog

Marine Coolant Heater Catalog Marine Coolant Heater Catalog Sure Marine Service, Inc. 5320 28th Ave. N.W. Seattle, WA 98107 (800) 562-7797 (206) 784-9903 Marine Coolant Heater Catalog Introduction... 4 Sizing Considerations... 4 Table

More information

Canadian Retail. Parts Catalogue

Canadian Retail. Parts Catalogue Canadian Retail Parts Catalogue 2017 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Water to Air Heat Exchangers / Water to Water Heat Exchangers Tube & Shell Heat Exchangers / Sidearm Exchangers / Grundfos Pumps Taco

More information

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) THE HEATING BOX Training Manual Model KD-HBO100 & KD-HBC100 * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) Automatic Hot Water Management System A Combination System for Domestic Water and

More information

FULL PORT BALL SWEAT X PEX W/WASTE /2" PEX X 1/2" SWEAT BALL VALVE W/WASTE & LEVER HANDLE

FULL PORT BALL SWEAT X PEX W/WASTE /2 PEX X 1/2 SWEAT BALL VALVE W/WASTE & LEVER HANDLE PRODUCT GROUP # 5 PEX-READY VALVES, TOOLS & ACCESSORIES - valves FULL PORT BALL VALVES w/waste (BC) 4490 /2" FULL PORT BALL VALVE W/ WASTE PEX X PEX 440075 3/4" FULL PORT BALL VALVE W/ WASTE PEX X PEX

More information

CSD-1 COMMERCIAL BOILER CONTROLS

CSD-1 COMMERCIAL BOILER CONTROLS SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock

More information

Clean. Safe. Reliable. WaterPEX.

Clean. Safe. Reliable. WaterPEX. Clean. Safe. Reliable. WaterPEX. Our Complete System of Pipes, Valves, and Fittings for Plumbing is Even More Comprehensive The future of plumbing systems is WaterPEX. W ith 125 years of experience, Watts

More information

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents Hoffman Specialty Regulators Main Steam How to Select Steam Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater Mains Vent (only) Remarks 1A X Adjustable Orifice 70A X

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

DIVISION 23 HVAC Hydronic Piping Systems

DIVISION 23 HVAC Hydronic Piping Systems General Information Programming/ Design Bidding/ Preconstruction Installation/ Construction Closeout/ Warranty QA/QC Checklist Construction Services DIVISION 23 HVAC 23 21 13 Hydronic Piping Systems 01

More information

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range Valves, controls + systems Innovation + Quality Stations for solar energy and solid fuel boilers Product range Stations for solar energy and solid fuel boilers Content Page Summary Stations for solar energy

More information

PROMAX XL MODELS CIRCULATING LOOP HEAT EXCHANGER MANUAL. Installation. Operation. Maintenance. Fill in the Rating Pate Information Here:

PROMAX XL MODELS CIRCULATING LOOP HEAT EXCHANGER MANUAL. Installation. Operation. Maintenance. Fill in the Rating Pate Information Here: CIRCULATING LOOP HEAT EXCHANGER MANUAL PROMAX XL MODELS Installation Operation Maintenance Fill in the Rating Pate Information Here: MODEL NO. SERIAL NO. INSTALLATION DATE Month Day Year CAUTION PLEASE

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

2012 Canadian Full Line Catalogue

2012 Canadian Full Line Catalogue 2012 Canadian Full Line Catalogue RESIDENTIAL COMMERCIAL INDUSTRIAL 2012 WattsRadiant Product Catalogue Contents 1 RadiantPEX RadiantPEX Tubing 1-1 RadiantPEX Connection Types 1-2 RadiantPEX Fittings

More information

ILLUSTRATED PARTS LIST

ILLUSTRATED PARTS LIST ILLUSTRATED PARTS LIST MODELS 200DW 200G 300G 900DW 900G 200DW 3000 & 6000P For additional information on Thermodyne Foodservice Products, Inc., or to locate an authorized parts and service provider in

More information

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames Instruction Sheet P/N 1111 01 Rhino SD/XD ARW Air Circuit Module for 15-mm Frames Description See Figure 1. The Rhino SD/XD ARW (automatic removal of weepage) air circuit module for 15-mm frames consists

More information

CONNECTION SYSTEM Reliance Worldwide USA

CONNECTION SYSTEM Reliance Worldwide USA CONNECTION SYSTEM Reliance Worldwide USA AUGUST 2010 The SharkBite Connection System Includes Push-Fit and Barb Products and PEX tubing. CONTENTS Introduction and Applications...........................................

More information

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website: Gas Range Catalogue by NEW PRODUCT! Hob Mate Manufactured to EN 15266 CSST Corrugated Stainless Steel Tube Online Videos Available The Hob Mate has been specifically designed to provide a fast and efficient

More information

Honeywell Water Solutions. Thermostatic Mixing Valves

Honeywell Water Solutions. Thermostatic Mixing Valves Honeywell Water Solutions Thermostatic Mixing Valves AMX300 Thermostatic Mixing Valve Kit Key Features and Benefits Kit includes mixing valve, cold water tee, flexible 8" or 11" metal connectors, and thermostrip

More information

The electrical wattage needed by the circulator is:

The electrical wattage needed by the circulator is: The electrical wattage needed by the circulator is: w e = 0.4344 f P n w/w A current-generation wet-rotor circulator has a maximum wire-towater efficiency in the range of 25 percent. If we put the data

More information

Modular Panel System for Radiant Floor Heating.

Modular Panel System for Radiant Floor Heating. Modular Panel System for Radiant Floor Heating Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel system an easy install and a great value

More information

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

Series 1156F, 1450F ( 1 2) Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers Used on boiler feed lines to provide make up water to the system Highest capacity performance Unique unitized

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

281 Series. ThermoBloc boiler protection recirculation and distribution unit.   Installation, commissioning and servicing instructions www.caleffi.com NA1094.01 ThermoBloc boiler protection recirculation and distribution unit Copyright 013 Caleffi Installation, commissioning and servicing instructions 81 Series Function The ThermoBloc

More information

2 DESCRIPTION OF SYSTEM COMPONENTS

2 DESCRIPTION OF SYSTEM COMPONENTS 2 DESCRIPTION OF SYSTEM COMPONENTS Buderus Panel Radiators Buderus Solidoflux N panel radiators are manufactured from.049 (1.25 mm) thick steel panels. They consist of water-filled steel welded radiative

More information

Parts List for Ener-Radiant XL Tube Heaters

Parts List for Ener-Radiant XL Tube Heaters Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.

More information

Installation of the Indoor Unit

Installation of the Indoor Unit stallation of the door Unit Firmly secure the evaporator mountg plate on a wall strong enough to withstand the weight of the unit. The plate must be level and allow for the clearances shown the figure

More information

Engineering Specifications

Engineering Specifications BRONZE BALL VALVES Model 2970 and Model 2970.10 PART 1: GENERAL 1.1 SUMMARY A. General duty press end type bronze ball valve 1.2 DEFINITIONS A. The following are standard abbreviations for valves: 1. WOG:

More information

13.2 Component Illustrations, Parts Lists, and Part Numbers

13.2 Component Illustrations, Parts Lists, and Part Numbers Page 0 LAARS Heating Systems Section REPLACEMENT PARTS Use only genuine LAARS replacement parts.. General Information To order or purchase parts for the LAARS MagnaTherm Appliance, contact your nearest

More information

Hydronic Product & Application Catalog

Hydronic Product & Application Catalog Hydronic Product & Application Catalog Brazed Plate Heat Exchangers MJanuary 2005 for: Radiant Floor Heating Domestic Water Heating Snow Melt Swimming Pools Steam Close Approach High Pressure Systems Multi-Purpose

More information

Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH30QB-1 A-VFH36QB-1 A-VFH42PB-1.

Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH30QB-1 A-VFH36QB-1 A-VFH42PB-1. Owner s Manual VFH-B Series Inverter Multi Zone Ductless Mi-Split A-VFH30QB-1 A-VFH36QB-1 A-VFH42PB-1 www.marsdelivers.com In le with the MARS policy of contual product improvement, the aesthetic and dimensional

More information

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801) INSTALLATION MANUAL Manufactured by AQUA-AIR MANUFACTURING 542 W. 47 Confluence East 800 South, Ave., Salt Ivins, Lake Utah City, 84738 Utah 84123 (801) 265-9699 or (800) 916-5777 FAX (801) 268-3856 (435)

More information

Instruction Sheet X Pump Block (XPB)

Instruction Sheet X Pump Block (XPB) R Instruction Sheet X Pump Block (XPB) 02-202 SUPERSEDES: July, 200 EECTIVE: October, 200 Plant ID#: 00-3883 General WARNING SYMBOL: THIS SYMBOL INDICATES THE PRESENCE O HAZARDS WHICH CAN CAUSE SEVERE

More information

Value Pre-Heat Appliance Installation Manual

Value Pre-Heat Appliance Installation Manual Module 12 Value Pre-Heat Appliance Installation Manual 1 & 2 Collector Pre-Heat Appliances (EWRA1, EWRA2) 1 & 2 Collector Pre-Heat Appliances (EWRA1-DWHX, EWRA2-DWHX) Rev. 2013,04,26 Solar Water Heating

More information

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the

More information