Allcan TM Installation Manual
|
|
- John Porter
- 5 years ago
- Views:
Transcription
1 Allcan TM Installation Manual
2 NOTICE: READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW INSTRUCTIONS VOIDS WARRANTY. Introduction: The PHP Allcan (USA patent pending) is a complete primary/secondary zoning package including air elimination and additional zone mixing capability. The Allcan reduces the space required for installation by utilizing an innovative pipe-in-pipe design and hydraulic separation that allows for a compact assembly. This process reduces the required time and materials typically used in a field-assembly of a zoned radiant heating system. Additionally, with the reduction of copper pipe and fittings, solder and flux, and space requirements, the Allcan contributes to green practices by reducing the amount of waste and the amount of transportation costs inherent in the supply of standard copper piping materials. The Allcan improves installation efficiency since the majority of system piping requirements are included within the compact design. Components are positioned properly for optimal performance. The expansion tank is located at the Point of No Pressure Change. The primary piping includes the primary circulator and taps for an indirect water tank while the secondary side can include up to 6 zone pumps. The Allcan can be fitted with either a 3-way manual mixing valve or a 3-way Taco ivalve to achieve multiple temperature delivery. Built into the assembly is a unique air eliminator which, combined with a pressure-reducing fill valve, completes the predominant system components. The use of end-suction flanges on zone pumps allows the output of the pump to be directed to facilitate piping connections. The end-suction flanges also contribute to the compact nature of the Allcan by limiting the width to 16 inches. The Allcan is also available with in-line pumps as an alternative pump option. The in-line pumps increase the width to 32 inches. The installing contractor saves installation time and space requirements in the mechanical room while being assured of proper system performance. The Allcan eliminates piping errors that may occur in field-assembled installations, especially when those installations include primary/ secondary, indirect water tank, zone pumping and mixing requirements. The Allcan is factory pressure-tested and PHP provides a 3-year leak-free warranty. Hydraulic Separation: The internal hydraulic separation chamber hydraulically uncouples the primary and secondary loops to prevent ghost flows similarly to closely-spaced Tees. Mixing patterns are dependent on flow rates in the primary and seconday loops as shown. A: Primary loop flow is GREATER than secondary loop flow - the secondary zones will always be the temperature of the primary loop. Secondary loop B: Primary loop flow EQUALS secondary loop flow - there is no mixing in the chamber. The secondary loops are the temperature of the primary loops and the boiler return is the temperature of the secondary return. C:Primary loop flow is LESS than secondary loop flow - secondary loops will be lower temperature than primary loop. Secondary loop Primary loop A B C Primary loop
3 Allcan TM Details Removable top assembly with two O-rings attaches with four screws (allows for Swirl Chamber instection and clean-out) Spriotop and internal Swirl Chamber eliminate air Top mounting bracket Zone pumps with end-suction flanges and check valve (pump outlet may be rotated up or down to accommodate system piping) Secondary-loop returns Temperature/pressure gauge Lower mounting bracket Sediment clean-out port Internal hydraulic separator Removable bottom assembly with two O-rings attaches with four screws (must be aligned with return line forward) Fast-fill pressurereducing valve Primary boiler pump with check valve (direction of flow is down when installing pump) Indirect DHW supply Boiler supply Indirect DHW return Boiler return Expansion tank with mounting bracket
4 Component Details: End-suction pumps: The default configuration for the secondary-loop pumps is the Grundfos I speed pump mounted to a proprietary PHP end-suction flange. The end-suction flange allows fluid to be drawn into the center of the pump impeller. The fluid is then directed 90 o from to inlet to the outlet. The pump must be mounted horizontally to properly lubricate the bearings. However, the outlet may be rotated up or down to facilitate system piping. Mixing options: To provide multiple secondary temperatures, the end-suction pumps may be fitted with a manual 3-way mixing valve kit or a Taco 3-way ivalve. When a mixing valve kit is used, the pump points sideways. The pump inlet must remain horizontal, however, the outlet may still be rotated. Pump outlet may be rotated 90 o. Outlet may be up, down, back, or forward. Pump inlet must be horizontal For the pumps and air elimination to work properly, the Allcan MUST be mounted vertically with the Spriotop at the top. Check valves: All zone pumps include a spring check assembly. The larger piece with the spring check goes onto the pump outlet, followed by the sweat adaptor. Use the supplied gasket to connect the spring check assembly to the pump outlet. The Allcan primpary pump may be used as a variable-speed injection pump allowing the Allcan to function as a variable-temperature injection module. The Allcan primary pump will be operated by a variable-speed injection controller. A separate primary-loop pump will be needed to maintain system flow and/or return water temperature to the boiler. Air elimination: At the top of the Allcan body is the Swirl Chamber. When a zone pump is operating, water is directed against the chamber wall causing it to swirl. This change of direction and volume causes a pressure change in the water to effectively eliminate air. The water swirls up the chamber wall and is drawn between the chamber wall and outer Allcan wall into the supply chamber where the pumps circulate to the various zones.
5 Allcan TM Operation 4) Compact, space-saving end-suction pumps circulate water to heating zones from the supply chamber of the Allcan. 3) Spirotop releases air from swirl chamber. 2) When a secondary-loop pump turns on, water travels up the internal supply pipe to the swirl chamber where aire is released. The water then flows between the Allcan wall and swirl chamber into the supply chamber where it is pumped to the corresponding zones. 5) Secondary-loop return water enters the internal return header which directs the flow back to the hydraulic separation chamber. The hydraulic separation chamber is the space between the circular plate with the secondary-loop supply/return connections and the bottom assembly with the primary-loop supply/return pipes. 1) Primary loop water circulates from the boiler to the hydraulic separation chamber. If there is no flow from the Allcan secondary-loop pumps, the primary-loop pump will circulate water from the boiler supply, through the hydraulic separation chamber, and back to the boiler. No heated water will be supplied to the zone pumps. Primary-loop return Primary-loop supply
6 Installing the Allcan: READ THESE INSTRUCTIONS CARE- FULLY. FAILURE TO FOLLOW INSTRUC- TIONS VOIDS WARRANTY. Installing the Allcan requires that you are a qualified installer with knowledge of local, national and other applicable building and mechanical codes, as well as an understanding of good hydronic practice, heat transfer, building heat requirements, friction losses, flow and control. If you do not have these skills you should not install the Allcan. It is the installers sole responsibility to verify the suitability of the Allcan for the project in which it is to be installed. 1) Unpack the Allcan and make sure you have received all the parts in good condition. Verify you have received the correct model for your job. The Allcan is available in the models shown elsewhere in this manual. The primary loop return pump and boiler return piece are normally shipped unattached. The return pump will be the conventional inline pump. The end suction pumps will be packed in boxes with the check valve assemblies on the outlet flange. The spirotop air vent may be removed in larger models so it will fit in a smaller box. The expansion tank, fill valve and expansion tank bracket are a separate assembly that will be installed once the Allcan is securely mounted to the wall. 2) Evaluate your mechanical room space and decide where you will place the Allcan with consideration where other components will be placed, and the components that will be connected to the Allcan. Also check as to required clearances to electrical panels and other components in a mechanical area. 3) It is recommended that 3/4 plywood be attached to the wall behind the Allcan installation location with the 3/4 plywood securely attached to framing. 4) Mount the Allcan vertically to the plywood, using four (4) 1 lag screws on both the upper and lower support bracket struts. Use washers to prevent the lag screws from working through the strut. 5) If the Spirotop has been removed for shipping, reinstall it using teflon sealing tape on the 1/2 threads. Do not over tighten. 6) Install the primary loop return pump and boiler return pipe assembly to the bottom of the Allcan. Use a gasket and 2 pump bolts on either side of the pump to securely attached the pump to the flanges. Make sure the direction of flow arrow of the primary loop return pump is DOWN. 7) Remove the end suction pumps from the boxes and attach them to the secondary loop outlet union flanges on the left and right of the Allcan. Use one of the provided gaskets on each. The check valve assembly is on the outlet of the pump. To this is attached a flanged sweat union. To prevent damage to the check valve, remove this flanged sweat union and sweat a starter piece of copper pipe to it then reattach the union to the check valve assembly. Make sure both the check valve assembly and the sweat union have a provided gasket installed and tighten. 8) Install fill/expansion tank assembly by aligning fill pipe union, and attaching expansion tank bracket to the plywood with two (2) 1 lag screws. 9) Pipe secondary-loop supply and return zones to the Allcan. Use a starter piece of copper as described in step 7 above to begin the secondary-loop supply piping from the end suction pumps. It is advisable to install a purge valve on the secondary loop return lines at a high point just before the connection to the Allcan secondaryloop return port ball valve. This will facilitate purging air out of the system with the secondary return port valve closed. 10) Pipe between the Allcan primary-loop supply in port to the boiler supply out port. Pipe between the Allcan primary loop return out port to the boiler return port.
7 11) If an indirect water tank is being used with the Allcan, pipe to and from the Allcan indirect supply and return ports. Be sure to use an appropriately sized pump with a spring check valve and good piping practice to prevent inducing undesired flow through the indirect tank. A DHW kit with the pump may be ordered from PHP. If indirect DHW tank is not being used make sure DHW taps are capped. 12) Pressure test the system as required by good practice and code. Wire pumps and controls. Fill with fluids. If necessary, protect system from freezing with propylene glycol or other methods. 13) Purge primary- and secondary-loops prior to operation of boiler or other heated water producing appliance. Purge secondary-loop zones one at a time sequentially with the secondary-loop return port ball valve closed and purge valve recommended in step 9 open and connected to a hose terminated out of doors or in a drain. Then once all zones have been purged close purge valves, open secondary-loop return port ball valves and run secondary-loop pumps sequentially to further purge system. Then operate primary-loop and DHW pumps to purge primary-loop. Only after system is well purged should boiler or other heated water prodcucing appliance be operated. Installing the Allcan with Taco in-line pumps: The support bracket for the Allcan is much wider to accomodate the in-line Taco pumps which point out sideways from the left and right of the Allcan. Mount the pumps to the flange with direction of flow pointing outward. Use only pumps with an internal spring check valve. Use one cushion clamp per pump to clamp the outboard side of the pump flange assembly to the vertical outrigger strut. When installed with in-line pumps, the unit is approximately 32 wide as opposed to the 16 wide Grundfos end-suction flange version, The two models are NOT interchangeable. Mixing modules are not an option when using in-line pumps. WARNINGS! Never operate boiler with expansion tank disconnected or isolated from the system. Failure to do so can result in explosive condition, injury or death. Purge air from system before operating pumps. Water lubricated pumps will fail if air-locked or run dry for extensive periods of time. Many boilers require a specific flow for correct operation and can differ significantly in resistance to flow. This may or may not require a pump substitution. It is the installers responsibility to verify the correct pump. Failure may cause premature failure of boiler or a dangerous condition. Make sure boiler or heat source has properly operating 30 PSI pressure relief valve connected to the system and and in good working condition. Never isolate it. Failure to do so may result in explosive condition, injury or death. It is the installers responsibility to install a code compliant backflow preventor on the fill line. The expansion tank supplied with the Allcan may not be the correct or adequately sized tank under certain conditions. It is the installers responsibility to verify that it is adequate, and if not replace it with a larger tank or add another so that the acceptance capacity is adequate for the system. Read and follow all instructions of components supplied as part of the Allcan. Always disconnect power from any component of the allcan or any connected to the Allcan before servicing the unit. Failure to do so could result in burns, electrocution, injury or death. For indoor hydronic use only. Do not use with steam or in steam heating applications.
8 Sample Mechanical Room Dimensions Front View Side View
9 Notes
10 Submittal Data Information Allcan tm Job: Engineer: Contractor: Rep: ITEM NUMBER MODEL NUMBER Application: The Allcan is a hydraulic separator with a high quality air separator built in. It is the space saving complete solution for any boiler. When configured with end-suction flanges, the top two pumps may be swiveled up and the bottom two down to aid in easy piping to the secondary-loop heating zones. This product comes with wall mounting brackets, fill valve, expansion tank, internal air separator, air vent, secondary loop Grundfos end-suction zone pumps (standard) or Taco 00R-MS in-line pumps (optional), primary loop pump/indirect water tank pump as specified, primary loop T s for an indirect water tank kit, and wall mounting hardware that includes an expansion tank retention mount. Optional secondary-loop mixing kits for multi-temperature systems are available using manual 3-way mixing valves or Taco 3-way ivalves. Models: All Products U.S. Patent Pending Part Number Description Primary & Optional Indirect Pump Secondary Pump PHP-ALLCAN-2G PHP-ALLCAN-2T PHP-ALLCAN-4G PHP-ALLCAN-4T PHP-ALLCAN-6G PHP-ALLCAN-6T 2-zone with Grundfos pumps 2-zone with Taco pumps 4-zone with Grundfos pumps 4-zone with Taco pumps 6-zone with Grundfos pumps 6-zone with Taco pumps UPS FC 0011-F UPS FC 0011-F UPS FC 0011-F UPS FC 00R-MS UPS FC 00R-MS UPS FC 00R-MS Note: The available head and flow in any manifolded pumping application is surprisingly dynamic. When more pumps come on, flow goes up, but not in a linear way since it is also influenced by the pressure drop and total flow rate of the manifold. Thus available flow at the same head loss will be reduced per pump when multiple pumps are on. Due to the dynamic difficulties of predicting all possible permutations of pressure and flow with multiple pumps and with multiple speeds it has become customary in the industry to use the single pump curves to design for each individual zone. Head (ft) Grundfos 1 UPS FC (hi spd) 2 UPS FC (med spd) 3 UPS FC (low spd) 4 UPS FC (hi spd) 5 UPS FC (med spd) 6 UPS FC (low spd) Flow (gpm) Head (ft) Taco F 2 00R-MS (hi spd) 3 00R-MS (med spd) 4 00R-MS (low spd) Flow (gpm) Precision Hydronic Products - Division of JL industries, inc NE 79th Court - Portland, OR Phone: ; Fax:
11 Submittal Data Information Allcan tm Job: Engineer: Contractor: Rep: ITEM NUMBER MODEL NUMBER Precision Hydronic Products - Division of JL industries, inc NE 79th Court - Portland, OR Phone: ; Fax:
12 Precision Hydronic Products Airport Business Center 6730 NE 79th Court - Portland, OR Phone: ; Fax:
Crown Boiler Company
Crown Boiler Company 1 Phantom Boiler System Combi Kit Instruction Manual I Product Description This kit adds the ability to generate DHW, as well as heat, ( combi capability) to select Phantom models
More informationpropanel Series Installation Manual
propanel Series Installation Manual propanel Series Installation Manual is published by Uponor Wirsbo 5925 148th Street West Apple Valley, MN 55124 (952) 891-2000 2003 Uponor Wirsbo All rights reserved
More informationPhiloWilke Partnership Addendum No. 2 A/E Project No April 2016
SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.
More informationHydronic Mechanical Panels
Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.
More informationINSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE
INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS
PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate
More informationPATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION
PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION On Off Combine a forged brass manifold and components to streamline boiler and secondary loop installations. Eliminates costly field
More informationPATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION
PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION On Off Combine a forged brass manifold and components to streamline boiler and secondary loops installations. Eliminates costly field
More informationINSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC
INSTALLATION INSTRUCTIONS GEO PRIME TANK (Patent Pending) GPC Table of Contents General Description 2 Installation 3 Flushing and Purging 5 Initial Start up 7 Adding or Checking Fluid 8 Replacing a Pump
More information"Best Practices in Modern Hydronic Heating - THE DETAILS
"Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r
More informationINSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER
INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER Build Equinox support@buildequinox.com (773)-492-1893 Rev 2.0-05/10/2018 Build Equinox 2018 The Geo-Boost system consists of the Geo-Boost heat
More information/99 USA. Installation Manual SU Save These Instructions!
46992 7/99 USA Installation Manual SU 160-200 Save These Instructions! TABLE OF CONTENTS 1 General Guidelines 3 2 Technical Data and Tank Connections 4 3 Transportation and Placement 5 4 Installation 6
More informationINSTALLATION INSTRUCTIONS WARRANTY
QT FLOW CENTER INSTALLATION INSTRUCTIONS Fig. 1. Low Head Pump Center Flow Chart Fig. 2. High Head Pump Center Flow Chart NOTE: Read the entire instruction manual before starting the installation. WARRANTY
More informationTOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!
1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based
More informationThermostatic mixing valves with interchangeable cartridges
www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems
More informationWATER-TUBE POOL HEATERS
XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,
More informationHPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations
Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control
More informationHYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler
SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS
More informationSECTION HYDRONIC PIPING AND SPECIALTIES
SECTION 15511 HYDRONIC PIPING AND SPECIALTIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Pipe Materials. 2. Fittings. 3. Specialty Items. 4. Glycol Antifreeze Protection. 5. Process Cooling B.
More informationWATER-TUBE POOL HEATERS
XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired
More informationNiles Steel Tank Hot Water Generator Installation and Operation Manual
Niles Steel Tank Hot Water Generator Installation and Operation Manual Contents: Contents 1 Hazard definitions 1 1. General Information.... 2 Availability... 3 Optional Control Packages... 5 2. Installation....
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationGeneral System Layout Sketch
General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems
More informationTaco 00 Series Cartridge Circulators
Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential
More informationSECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.
SECTION 15540 PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Base Mounted Pumps. 2. Horizontal Split Case Pumps. 3. In line Pumps. 4. Steam Condensate Return Pumps. B. Related Sections: 1. Section
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01900 Revision 2 Printed in Canada 1.1 INTRODUCTION Thank you
More informationHeat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T
Heat Link SSP Series SS Manifold Pump Panel Manual NEUTRAL GROUND LIVE CAUTION 115 VOLTS ONLY SSPLR106T GROUND LIVE NEUTRAL CAUTION 115 VOLTS ONLY 120 40 60 60 80 100 C F 200 0 180 20 40 140 160 80 100
More informationDIVISION FINNED WATER-TUBE BOILERS
MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section
More informationHVAC No. MFG Part No. Description Size Price
Circulator Isolation Flanges and Valves Webstone 113460 113462 113464 113466 390608 390564 Flanged Isolation Valves 110-251F 110-252F 110-253F 110-254F SF-075T SF-100T Freedom Flange, Cast Iron Freedom
More informationSlant Fin Corp. Installation and Operation Instructions
Slant Fin Corp. Installation and Operation Instructions CHS Series Figure 7-1 Gas Line Connection (Typical) Manual Gas Shutoff Valve Should overheating occur or the gas supply fail to shutoff, close the
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01524 Revision 15 Printed in Canada 1.1 INTRODUCTION Thank
More informationProduct Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen
Hydronic Mixing Block Version 1.104 The Hydronic Mixing Block is a mixing device and boiler control, with a built in circulator and system controller. The block can provide either a fixed or reset water
More informationInstallation. Manual. Installation. Startup Maintenance Parts WARNING
Installation Manual Installation Startup Maintenance Parts MH18082 WARNING This manual must only be used by a qualified heating installer/service technician. Read all instructions in this manual before
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationThermostatic mixing valves with replaceable cartridge for centralized systems
Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is
More information.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.
Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationE. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F
UDX No Sweat Kit instuctions The No Sweat Kit is intended to be used in conjunction with the AET s DB-10-10XC and DB-15-15XC on a 120 or 80 gallon OST (American Water Heater) top or side connect tank.
More information5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341
NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic
More informationGOLD Plus 30/40/60/80
PLUS Line Indirect-Fired Water Heaters Series 3 Manual Installation Startup Maintenance Parts PLUS 100/110/119 GOLD Plus 30/40/60/80 Plus 40/60/80 This manual must only be used by a qualified heating installer/service
More informationHeat Link MECHANICAL ROOM IN A BOX. SSP Series SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x SSPLR106T SSPSS106B
SSP Series SS Manifold Pump Panel Manual GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40 60 0 0 40 40 60 80 00 SSPLR06T GROUND LIVE NEUTRAL CAUTION 5 VOLTS ONLY 0 80 00 00 C F 80 60 40
More informationInstallation. Manual. Installation. Startup Maintenance Parts NOTICE WARNING
Installation Manual Installation Startup Maintenance Parts NOTICE When installing Models manufactured after July 7th, 2008, you will notice additional selections on the Installer Menu of the Control that
More informationPROMAX XL MODELS CIRCULATING LOOP HEAT EXCHANGER MANUAL. Installation. Operation. Maintenance. Fill in the Rating Pate Information Here:
CIRCULATING LOOP HEAT EXCHANGER MANUAL PROMAX XL MODELS Installation Operation Maintenance Fill in the Rating Pate Information Here: MODEL NO. SERIAL NO. INSTALLATION DATE Month Day Year CAUTION PLEASE
More informationInstallation & Operation Manual Models: TSU
TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.
More informationDOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:
INSTALLATION INSTRUCTIONS DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System Model: DORGPT-1 NOTE: This guide provides the installer with instructions specific to the Bard Double O-Ring Geo-Prime
More informationDIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe
DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function
More informationA hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.
Introduction to Hydronics A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes. Hydronic heating systems use hot water or steam to deliver the
More informationLC Series - Light Commercial Pump Station Installation and Operation Manual
LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump
More informationDIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS
MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS
More informationDIVISION FINNED WATER-TUBE BOILERS
MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section
More informationCommercial, Residential & Institutional Pumps, Tanks, & Accessories
Taco International Commercial, Residential & Institutional Pumps, Tanks, & Accessories Taco Catalog # : 300-6.0 Supersedes: 300-3.5 9/11/06 Effective Date: 03/21/07 Printed in USA Pumps FI Frame Mounted
More informationHydraulic Separation Moving Beyond Priamry / Secondary Piping...
Hydraulic Separation Moving Beyond Priamry / Secondary Piping... load! #1 load! #2 load! #3 primary! circulator presented by: John Siegenthaler, P.E. Appropriate Designs Holland Patent, NY www.hydronicpros.com
More informationA. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.
SECTION 23 21 23 - HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationA. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationVSL II QUICK START GUIDE
This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationECO1ZN3P, ECO2ZN4P ECO
WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN
More informationInterSeptor Centrifugal Separators Operating & Maintenance Manual
General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this
More informationBoiler Manual. Gas-fired water boilers. Featuring. Flexibility
Gas-fired water boilers Featuring Flexibility Boiler Manual This manual must only be used by a qualified heating installer/service technician. Read all instructions, including this manual and all other
More informationInstallation, commissioning and servicing instructions
NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation
More informationDIVISION FINNED WATER-TUBE BOILERS
MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More information9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.
77 Do not install the condensate assembly if a component is lost or missing. Replace the entire assembly. Failure to follow this warning could result in property damage, serious personal injury, or death.
More informationModular Panel System for Radiant Floor Heating.
Modular Panel System for Radiant Floor Heating Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel system an easy install and a great value
More informationWayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No
SECTION 213113 - ELECTRIC-DRIVE, CENTRIFUGAL FIRE PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationHeat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.
Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow
More informationPRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL
FloorHeat PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL Thank you for purchasing this radiant control panel assembly. Following are some important notes that will make the installation successful.
More informationOutdoor Knight Boiler Installation & Operation Manual Models:
OKB-I-O Rev G Outdoor Knight Boiler Installation & Operation Manual Models: 151-286 This manual must only be used by a qualified heating installer / service technician. Read all instructions, including
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationINSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER
1103 N HIGH CROSS RD URBANA, IL 61802 1-773-492-1893 INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER REV 1.0 The Geo-Boost system consists of the Geo-Boost heat exchanger and a relay controller
More informationENERVEX VHX VORTEX HEAT RECOVERY CENTER
ENERVEX VORTEX HEAT RECOVERY CENTER 3002603 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F:
More informationThreaded. Flanged. Model PSH. Primary Secondary Header A-451
Threaded Flanged Model PSH Primary Secondary Header A-451 The History of Primary-Secondary Pumping Did you know that Bell & Gossett invented Primary-Secondary Pumping? This widely popular pumping arrangement
More information568X, 587X, 588X Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationInstallation Instructions for use by heating contractor. VITOCELL r 300-H CAUTION IMPORTANT. Read and save these instructions for future reference.
Installation Instructions for use by heating contractor Vitocell 300-H EHA Series Indirect-fired domestic hot water storage tank 42 USG to 119 USG (160 L to 450 L) capacity VITOCELL r 300-H CAUTION The
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationAFUE 95% Heating Input 50,000 to 200,000 Btuh
PRODUCT SPECIFICATIONS WATER HEATERS / BOILERS GWM-IE Gas-Fired, Modulating, Condensing, Wall Hung Hot Water Boiler Bulletin No. 210650 March 2018 Supersedes December 2015 AFUE 95% Heating Input 50,000
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationBoiler Manual. Commercial Condensing Gas-fired water boilers
TM Commercial Condensing Gas-fired water boilers Boiler Manual This manual must only be used by a qualified heating installer/service technician. Read all instructions, including this manual and all other
More informationunion swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve
VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging
More informationMC Series Gas-Fired Circulating Heater
MC Series Gas-Fired Circulating Heater INSTALLATION START-UP MAINTENANCE PARTS Models MC50 / MC80 MC99 / MC120 When installing models manufactured after July 7, 2008, you will notice additional selections
More informationProduct Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers
Companion Water Heater for WM97+ Gas-Fired Boilers Product Manual Installation Startup Maintenance Parts High Performance Companion Water Heater (Boiler sold separately) This manual must only be used by
More informationGB Condensing Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB142/45 wall-hung condensing hot water boiler(s), suitable for induced
More informationProRadiant Manifolds, Stations and Fittings
Manifolds, Stations and Fittgs 197 Staless Manifolds and Accessories # of Outlets STAINLESS MANIFOLD - SHUT-OFF / BALANCING / FLOW METERS These preassembled 1-1/4" diameter staless supply and return manifolds
More informationHPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations
Series 600 LFI / CFI Series 700 HFS Zone Control Stations Heating and Radiant Floor Zone Control Stations Installation Instructions Thank you for purchasing the finest in heating and radiant floor Control
More informationXTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS
XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS
More informationDIVISION 23 HVAC Hydronic Piping Systems
General Information Programming/ Design Bidding/ Preconstruction Installation/ Construction Closeout/ Warranty QA/QC Checklist Construction Services DIVISION 23 HVAC 23 21 13 Hydronic Piping Systems 01
More informationInstallation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K36E Modular Heating
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationRemote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)
Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation
More informationBrazed Plate Heat Exchanger Operations Manual
razed Plate Heat Exchanger Operations Manual razed Exchanger Operations Manual razed Heat Exchangers from Polaris deliver exceptional strength and performance in a compact package. These versatile units
More informationINSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2
INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2 Publication No. 01906 Revision 0 Printed in Canada 1.1 INTRODUCTION
More informationAIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015
1.1 GOALS The goal of this section is to provide guidance in the design of Plumbing and Fire Protection systems to LAWA standards. The LAWA Plumbing Design Standards are a compilation of general design
More informationWilo IL Vertical Split-Coupled Inline Pumps
Wilo IL Vertical Split-Coupled Inline Pumps Vertical Inline Split-Coupled, Single Stage Pumps March, 2013 Marcos D. Roimicher, Product Manager BS Market Segment, Product Management Department 120-08-002-0313
More informationAPPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation
OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature
More informationDIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS
XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY
More informationHYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008
SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Air separators B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS A. Section - Plumbing Piping Specialties B. Section
More informationInstallation, Operating, and Maintenance Manual
www.geo-flo.com Engineered Solutions Making Geothermal Easier Installation, Operating, and Maintenance Manual To/From Ground Loop To/From Heat Pump Part # 3761 Rev. 03OCT2016 NP and NP Plus Non-Pressurized
More informationTechnical Data Manual Model Nos. and pricing: see Price List
Technical Data Manual Model Nos. and pricing: see Price List VITOCELL 300-H EHA Series Indirect-fired domestic hot water storage tank 42 to 119 USG (160 to 450 L) Product may not be exactly as shown Vitocell
More informationINSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !
Condensate Return Systems General Installation, Operation, & Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. SAFETY INSTRUCTIONS This safety alert symbol will be used in this
More informationINSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)
INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL) Publication No. 01553 Revision 8 Printed in Canada 1.1 INTRODUCTION This manual
More information