PRODUCT GUIDE. Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ Phone Fax Web Seeleyinternational.

Size: px
Start display at page:

Download "PRODUCT GUIDE. Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ Phone Fax Web Seeleyinternational."

Transcription

1 PRODUCT GUIDE 2017 Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ Phone Fax Web Seeleyinternational.com Seeley International has a policy of continuous product development and therefore reserves the right to make changes to cooler specifications without notice.

2 EXT 155/265 2 Speed Most Common Replacement Parts EXT 155/265 PART MFG# DESCRIPTION ORDER # J-BOX 2 SPEED MOTOR 2 SPEED 3/4 HP Breezair Model MFG# Industry Standard CFM Volts Amps Hi/Low Motor HP Weight LB Order # TORNADO WATER PUMP 115V EXT / HP 172 EXT / HP BLEED OFF FUNNEL/DRAIN ADAPTER EXT 155/265 MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING 2-SPEED JUNCTION BOX SEELECTRIC 2-SPEED MOTOR FAN ASSEMBLY TORNADO WATER PUMP FLOAT FALVE BLEED-OFF TRAY FOUR(4) CHILLCEL PADS EXT155 ROOF JACK ADAPTER 19 3/4 X 17 3/4 INCHES EXT265 ROOF JACK ADAPTER 19 3/4 X 19 3/4 INCHES L480-S VERTICAL FLOAT VALVE CHILLCEL PAD 31.5X17.5X3.5 EXT155 (Set of 4) CHILLCEL PAD 31.5X25X3.5 EXT 265 (Set of 4) V-BELT A-46/ 4L-480 EXT155 MFG# OPTIONS Description SALINITY MANAGER (INCLUDES CONTROL BOX, AUTO DRAIN, SOLENOID, WATER PROBE AND PLUMBING FITTINGS) Order# V-BELT A-55/ 4L-570 EXT265 BEARING KIT

3 DIA# MFG# DESCRIPTION ORDER # Lid Beige Tank Beige Leg Extension 3A Leg Extension Foot Pad Frame Beige Chillcel Pad 31.5 x 17.5 x 3.5 EXT155 (Set of 4) Chillcel Pad 31.5 x 25 x 3.5 EXT265 (Set of 4) 6A Pad Retaining Pin 6B Pad Retaining Disc Spreader Water Distribution 7A way water Distributor 7B N/A Water Distribution Hose (special order) Corner Post EXT Corner Post EXT 265 8A Corner pad Clips Transition Scroll to Lid EXT Scroll Assembly EXT Scroll Assembly EXT J box 2 speed Motor Mount Plate Motor Mount Plate Motor 2 Speed 1/2 HP Motor 2 Speed 3/4 HP Motor 2 Speed 1 HP Motor Pulley 3 1/2" 15 4L480-S V-belt A-46 4L-480 EXT V-belt A-55 4L-570 EXT Installation Hardware Kit Fan Pulley 8" EXT Fan Pulley 9" EXT Fan Centrifugal EXT Fan Centrifugal EXT Fan Shaft Square S/Steel Bearing Kit Tornado Water Pump 115V Bleed Off Funnel/Drain Adaptor Kit Vertical Float Valve/Float Assembly

4 EXV 155/275 Variable Speed Most Common Replacement Parts EXV 155/275 PART MFG# DESCRIPTION ORDER # CPMD J-BOX VARIABLE SPEED MOTOR VAR SPEED 3/4HP EXV155 MOTOR VAR SPEED 1HP EXV275 Breezair Model MFG# Industry Standard CFM Motor Weight Volts Amps Order # HP LB EXV HP 172 EXV HP 212 EXV 155/275 MODEL COOLERS COME EQIPPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX SEELECTRIC VARIABLE SPEED MOTOR FAN ASSEMBLY TORNADO PUMP FLOAT VALVE FOUR (4) CHILLCEL PADS EXV155 ROOF JACK ADAPTER 19 3/4 X 17 3/4 INCHES EXV275 ROOF JACK ADAPTER 19 3/4 X 19 3/4 INCHES PLEASE NOTE: EXV REQUIRES PURCHASE OF ONE OF THE FOLLOWING SPEED CONTROL KITS HARMONY SPEED CONTROL KIT INCLUDES WIRED WALL CONTROL WITH LEAD ASSEMBLY, SOLENOID AND HADRWARE, 24V AUTO DRAIN AND WATER PROBE HORIZON SPEED CONTROL KIT INCLUDES WIRELESS WALL CONTROL AND LEAD ASSEMBLY SOLENOID AND HARDWARE, 24V AUTO DRAIN AND WATER PROBE V AUTO DRAIN SOLENOID 24V WATER PROBE CHILLCEL PAD 31.5X17.5X3.5 EXV155 (Set of 4) CHILLCEL PAD 31.5X25X3.5 EXV 265 (Set of 4) V-BELT A-47/ 4L-490 EXV V-BELT A-56/ 4L-580 EXV TORNADO WATER PUMP 115V VERTICLE FLOAT VALVE BEARING KIT HARMONY SENSOR TOUCH WIRED WALL CONTROL HORIZON SENSOR TOUCH WIRELESS WALL CONTROL

5 DIA# MFG# DESCRIPTION ORDER # Lid Beige Tank Beige Leg Extension 3A Leg Extension Foot Pad Frame Beige Chillcel Pad 31.5 x 17.5 x 3.5 EXV155 (Set of 4) Chillcel Pad 31.5 x 25 x 3.5 EXV275 (Set of 4) 6A Pad Retaining Pin 6B Pad Retaining Disc Spreader Water Distribution 7A way water Distributor 7B N/A Water Distribution Hose(special order) Corner Post EXV Corner Post EXV 275 8A Corner pad Clips Transition Scroll to Lid EVT Scroll Assembly EXV Scroll Assembly EXV CPMD J Box Variable Speed 11A CPMD J-Box Mounting Cradle 11B Main Power Junction Box 11C Receiver Motor Mount Plate EXV Motor Mount Plate EXV Motor Variable Speed 3/4hp Motor Variable Speed 1hp Motor Pulley 4" V-belt A-47 4L-490 EXV V-belt A-56 4L-580 EXV Installation Hardware Kit Fan Pulley 8" EXV Fan Pulley 9" EXV Fan Centrifugal EXV Fan Centrifugal EXV Fan Shaft Square S/Steel Bearing Kit Tornado Water Pump 115V V Auto Drain Vertical Float Valve Solenoid Valve 24V (Not shown) Probe water sensor

6 EXH 170/210 Variable Speed Most Common Replacement Parts EXH 170/210 PART MFG# DESCRIPTION ORDER # CPMD J-BOX VARIABLE SPEED ECM MOTOR VARIABLE SPEED 1HP ECM MOTOR VARIABLE SPEED 2HP Breezair Model MFG# Industry Standard CFM Volts Amps Motor Size Weight Order # TORNADO WATER PUMP 230V EXH HP 212 EXH HP 212 EXH MODEL COOLERS COME EQIPPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX ECM DIRECT DRIVE MOTOR FAN ASSEMBLY TORNADO PUMP (230 VOLT) FLOAT VALVE FOUR (4) CHILLCEL PADS EXH170/210 ROOFJACK ADAPTER 19 3/4 X 19 3/4 INCHES VERTICLE FLOAT VALVE 24V AUTO DRAIN SOLENOID 24v PLEASE NOTE: EXH REQUIRES PURCHASE OF ONE OF THE FOLLOWING SPEED CONTROL KITS WATER MANAGER PROBE CHILLCEL PAD EXH170 (Set of 4) HARMONY SPEED CONTROL KIT INCLUDES WIRED WALL CONTROL WITH LEAD ASSEMBLY, SOLENOID AND HADRWARE, 24V AUTO DRAIN AND WATER PROBE HORIZON SPEED CONTROL KIT INCLUDES WIRELESS WALL CONTROL AND LEAD ASSEMBLY SOLENOID AND HARDWARE, 24V AUTO DRAIN AND WATER PROBE CHILLCEL PAD EXH210 (Set of 4) HARMONY SENSOR TOUCH WIRED WALL CONTROL HORIZON SENSOR TOUCH WIRELESS WALL CONTROL

7 DIA# MFG# DESCRIPTION ORDER # Lid Beige Tank Beige Leg Extension 3A Leg Extension Foot Pad Frame Beige Chillcel Pad Set of 4 EXH 170 (Set of 4) Chillcel Pad Set of 4 EXH 210 (Set of 4) 6A Pad Retaining Pin 6B Pad Retaining Disc Spreader Water Distribution 7A way water Distributor 7B N/A Water Distribution Hose special order) Corner Post 8A Corner pad Clips Transition Scroll to Lid Scroll Assembly CPMD J Box Variable Speed 11A J-Box Mounting Cradle 11B Main Power Junction Box 11C Receiver Motor Variable 1HP Motor Variable 2HP Fan Centrifugal Fan Shaft Round Alloy 20A Dust End Cap 20A Resilient Mount & Insert 20B Fan Shaft Seal Tornado Water Pump 230V Auto Drain 24V Vertical Float Valve Assembly Solenoid Valve 24V

8 TBA 450 Variable Speed Most Common Replacement Parts TBA 450 PART MFG# DESCRIPTION ORDER # CPMD J-BOX VARIABLE SPEED Breezair Model MFG# Industry Standard CFM Volts Amps Motor HP Weight LB Order # MOTOR VARIABLE SPEED 3/4 HP TBA HP 140 TBA MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX DIRECT DRIVE MOTOR/FAN TORNADO PUMP (230 VOLT) FLOAT VALVE FOUR (4) CHILLCEL PADS 21 5/8" x 21 5/8" ROOFJACK/WEATHERSEAL TRANSITION ASSEMBLY WITH TBA SENSOR TOUCH WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONAL PLENUM (AIR DIFFUSERS ) 4 SIDED OR 8 SIDED OPTIONS TORNADO WATER PUMP 230V VERTICLE FLOAT VALVE 24V AUTO DRAIN SOLENOID 24V SIDED PLENUM WATER PROBE SIDED PLENUM SMART HUB (65 CABLE INCLUDED) LINKS UP TO 4 COOLERS WITH SINGLE SMART HUB OR UP TO 41 COOLERS WITH 10 SWMART HUBS INDUSTRIAL WALL CONTROL KIT (65' CABLE, 131' CABLE AND REMOTE SENSOR INCLUDED) 65' CABLE ASSEMBLY 131' CABLE ASSEMBLY 197' CABLE ASSEMBLY 262" CABLE ASSEMBLY 328" CABLE ASSEMBLY CHILLCEL PAD 20.75X33.5X3.5 (Set of 4) TBA SENSOR TOUCH WIRED WALL CONTROL WEATHERSEAL TRANSITION ASSEMBLY WITH FLAPS

9 DIA# MFG# DESCRIPTION ORDER # Lid Grey Tank Grey Leg Support Kit with Foot (set of 4) 3A Leg Extension Foot 3B Weather seal Transition w/flaps 3C Weather seal Flaps only (2 ea) Pad Frame Grey Chillcel Pad x 33.5 x 3.5 (Set of 4) 6A Pad Retaining Pin 6B Pad Retaining Disc 7B N/A Water Distribution Hose (not shown) Pillar Corner Post Fan Inlet Ring CPMD J-box Variable Speed Motor variable 3/4 hp Fan Axial Tornado Water Pump 230V Auto Drain 24V Vertical Float Valve Solenoid 24V 25C Flexible Hose and Washer Assembly 25F Extension Tube 26A Probe Water Sensor

10 TBS 500 Variable Speed Most Common Replacement Parts TBS 500 PART MFG# DESCRIPTION ORDER # CPMD J-BOX VARIABLE SPEED Breezair Model MFG# Industry Standard CFM Volts Amps Motor HP Weight LB Order # MOTOR VARIABLE SPEED 1 HP TBS HP 140 TBS MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING VARIABLE SPEED CPMD JUNCTION BOX DIRECT DRIVE MOTOR/FAN TORNADO PUMP (230 VOLT) (UL) FLOAT VALVE FOUR (4) CHILLCEL PADS 21 5/8" x 21 5/8" ROOFJACK/WEATHERSEAL TRANSITION ASSEMBLY WITH TBS MagiQtouch WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONAL PLENUM (AIR DIFFUSERS ) 4 SIDED OR 8 SIDED OPTIONS SIDED PLENUM TORNADO WATER PUMP 230V (UL) VERTICLE FLOAT VALVE V AUTO DRAIN SOLENOID 24V WATER PROBE SIDED PLENUM MagiQtouch Air Sensor for Use with TBS500-G UL only CHILLCEL PAD 20.75X33.5X4.75 (Set of 4) MagiQtouch Multi Cooler Link Module for Use with TBS500-G UL only. (1 per Additional Cooler) MagiQtouch WALL CONTROL ' CABLE ASSEMBLY 6 Pin 131' CABLE ASSEMBLY 6 Pin 3M Communication Cable / Link Module WEATHERSEAL TRANSITION ASSEMBLY WITH FLAPS

11 DIA# MFG# DESCRIPTION ORDER # Lid Grey Tank Grey Leg Support Kit with Foot (set of 4) 3A Leg Extension Foot 3B Weather seal Transition w/flaps 3C Weather seal Flaps only (2 ea) Pad Frame Grey Chillcel Pad x 33.5 x 4.75 (Set of 4) 6A Pad Retaining Pin 6B Pad Retaining Disc 7B N/A Water Distribution Hose (not shown) Pillar Corner Post Fan Inlet Ring CPMD J-box Variable Speed Motor variable 1 hp Fan Axial Tornado Water Pump 230V (UL) Auto Drain 24V Vertical Float Valve Solenoid 24V 25C Flexible Hose and Washer Assembly 25F Extension Tube 26A Probe Water Sensor

12 TBSI 580 Variable Speed Most Common Replacement Parts TBSI 580 PART MFG# DESCRIPTION ORDER # CPMD J-BOX VARIABLE SPEED Breezair Model MFG# Industry Standard CFM Volts Amps Motor HP Weight LB Order # MOTOR VARIABLE SPEED 1 HP TBSI HP 150 TBSI MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING VARIABLE SPEED ICPMD JUNCTION BOX DIRECT DRIVE MOTOR/FAN TORNADO PUMP (230 VOLT) (UL) FLOAT VALVE FOUR (4) CHILLCEL PADS 21 5/8" x 21 5/8" ROOFJACK/WEATHERSEAL TRANSITION ASSEMBLY WITH TBSI MagiQtouch WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONAL PLENUM (AIR DIFFUSERS ) 4 SIDED OR 8 SIDED OPTIONS SIDED PLENUM TORNADO WATER PUMP 230V (UL) VERTICLE FLOAT VALVE V AUTO DRAIN SOLENOID 12V WATER PROBE SIDED PLENUM MagiQtouch Air Sensor MagiQtouch Multi Cooler Link Module for Use with TBSI580-G only. (1 per Additional Cooler) ' CABLE ASSEMBLY 6 Pin ' CABLE ASSEMBLY 6 Pin M Communication Cable / Link Module M Test Cable / Link Module CHILLCEL PAD 20.75X33.5X4.75 (Set of 4) MagiQtouch WALL CONTROL WEATHERSEAL TRANSITION ASSEMBLY WITH FLAPS

13 DIA# MFG# DESCRIPTION ORDER # Lid Grey Tank Grey Leg Support Kit with Foot (set of 4) 3A Leg Extension Foot 3B Weather seal Transition w/flaps 3C Weather seal Flaps only (2 ea) Pad Frame Grey Chillcel Pad x 33.5 x 4.75 (Set of 4) 6B Pad Retaining Pin 6B Pad Retaining Disc 10A Motor Mount SuperStealth Pillar Corner Post Fan Inlet Ring CPMD J-box Variable Speed Motor variable 1.3hp Fan Axial Tornado Water Pump 230V (UL) Auto Drain 12V Vertical Float Valve Solenoid 12V 25C Flexible Hose and Washer Assembly 25F Extension Tube 26A Probe Water Sensor

14 ENVIROMAGIC Variable Speed Most Common Replacement Parts ENVIROMAGIC PART MFG# DESCRIPTION ORDER # COOLER CONTROL BOARD Breezair Model MFG# Industry Standard CFM ENV , Volts Amps Motor HP Weight LB Order # ENV MODEL COOLERS COME EQUIPPED WITH THE FOLLOWING DIGITAL SMARTBOX CONTROL MODULE DIRECT DRIVE MOTOR/FAN HIGH VOLUME UL RATED CIRCULATION PUMP BUILDING MANAGEMENT SYSTEM ( BMS) INTERFACE NINE (9) CHILLCEL PADS ENV SENROR TOUCH WIRED WALL CONTROL WITH LEAD WATER MANAGER WITH AUTO DRAIN OPTIONS 131' CABLE ASSEMBLY MOTOR VARIABLE SPEED 2 HP HIGH VOLUME UL RATED CIRCULATION PUMP HIGH PERFORMANCE AXIAL FAN V AUTO DRAIN SOLENOID 24V WATER PROBE CHILLCEL PAD ENV SENSOR TOUCH WIRED WALL CONTROL

15 DIA# MFG# DESCRIPTION ORDER # Lid and Spreader Assembly Eye Bolts and Lifting Lugs Tank Assembly 3D Duct Attachment Channels 3E Mount Plate Pad Frame ENV Chillcel Pad 6A Pad Retaining Pin 6B Pad Retaining Disc Water Deflector Corner Pillar External Corner Pillar internal 8A Corner pad clips 8B Corner Clip Internal Fan Inlet Ring ( Venturi) Control Assembly 11D Wall Mount Plate for D ENV Sensor Touch Wall Control 11E Lead Assembly for Envriomagic only 65' 4 pin Collet for Motor Shaft Motor Variable Envriomagic Fan Axial Pump, Circulation NIDEC 22A Auto Drain 24V Enviromagic Solenoid valve 24V (Enviromagic only) 26A probe Sensor (Enviromagic only) Elbow(Pump to Spreader) 27A PVC Pipe Assembly 27B Joiner Barbed 27C Tee Piece for Tubing 27D Tube (Tank 2 to Tee) 27E Tube (Tank 2 to Tee) Cooler Control Board (Not Shown)

16 MOBILEMAX 2/3 Most Common Replacement Parts MOBILEMAX 2/3 PART MFG# DESCRIPTION ORDER # JUNCTION BOX MOBILEMAX 2/ SEELEY MOTOR 2SPD 3/4HP MMAX SEELEY MOTOR 2SPD 1HP MMAX3 Breezair Model MFG# Industry Standard CFM Volts Amps 2spd HI/LOW Motor Size HP Weight LB Order # TORNADO PUMP MMAX /5.6 3/4HP 188 MMAX / HP 210 MOBILEMAX COOLERS COME EQUIPPED WITH THE FOLLOWING 2-SPEED JUNCTION BOX SEELECTRIC 2-SPEED MOTOR FAN ASSEMBLY TORNADO PUMP FLOAT VALVE THREE (3) ASPEN PADS 26 GALLON WATER TANK 2-SPEED CONTROL SWITCH WATER FITTINGS FOR HOSE HOOKUP 20' POWER CORD HORIZONTAL FLOAT VALVE L-520/A50 FAN BELT MMAX L-570/A55 FAN BELT MMAX BEARING KIT ASPEN PAD 23 1/2 X 31 MMAX2 ASPEN PAD 32 X 34 MMAX3

17 DIA# MAG# DESCRIPTION ORDER # Tank MMAX2&3 Beige Tank MMAX2&3 Grey Lid Large MMAX2&3 Beige Lid Large MMAX2&3 Grey Front Panel Medium MMAX2 Beige Front Panel Medium MMAX2 Grey Panel Front Large MMAX3 Beige Panel Front Large MMAX3 Grey Pad Frame Medium MMAX2 Beige Pad Frame Medium MMAX2 Grey Pad Frame Large MMAX3 Beige Pad Frame Large MMAX3 Grey Aspen Pad (23.5x31) MMAX Aspen Pad Large(32x34)MMAX Pad Wire MMax Pad Wire MMax Corner Post Corner Post Plate Cut Off MMax Plate Cut Off MMax Switch Enclosure 15A Switch Plate 15B Toggle switch 30m Small Mods MMax Large Mods MMax Tornado Water Pump 115V

18

19 GENERAL DIAGNOSTICS

20 INTERPRETING LED'S TRI-COLOR-LED Green - Red - Amber Red-LED Red LED Indicator Operating and Fault Code Diagnosis RED COLORED LED: This LED indicates the status of the conductivity measurement circuit and the status of the Salinity Control Method (1) Flash every 2 Seconds (2) Flashes every 2 Seconds (3) Flashes every 2 Seconds Continuously On Salinity Control Method= Water Manager is Enabled Salinity Control Method= Water Manager is Enabled Salinity Control Method= Set to drain every 65 minutes of pump operation Salinity Control Method= Water Manager is Enabled Measured salinity is below the set point Measured Salinity is above the set point Cooler will Drain every 65 minutes of Pump Operation Probes are Open Circuit (No Water in the Tank) or measured salinity is less than 12PPM The TRI-COLOR LED (right-hand LED) is used as an operational fault indicator. Note TRI-COLOR LED double flashing every 2 seconds = Normal Operation TRI-COLOR LED Indication Cooler Condition Reason Clearing Faults TRI-COLOR LED (2) Green Flashes No fault Indicated Double flash every 2 seconds indicates that control is running Normally No Fault detected No Fault detected (2) Green Flashes 1. If the cooler receives a valid messaage while the (1) Red Flash Indicates Fault Code #1 Communication failure Fan, Pump and Inlet valve are turned OFF. The Drain Valve stays in whatever position it was in. Time lapsed since receiving a valid message from rremote Control exceeded 30 minutes fault code is present, the fault will be cleared and the cooler will opperate according to the message 2. Disconnect Power Supply to cooler for 10 seconds and then restore Power. Reverts to (2) Green Flashes (2) Red Flashes Indicates Fault Code #2 Failure to detect water at probes Water Inlet valve and Pump are turned OFF. Fan will be off unless control is set to Manual Vent Mode Water not detected at the probes for approximately 17 minutes Turn Remote Control off then on Reverts to (2) Green Flashes (4) Red Flashes Indicates Fault Code #4 Failure to Clear probes during drain Drain Valve Closed and pump turned OFF. Fan will be off unless control is set to Manual Vent Mode Water did not drain from tank within approximately 8 minutes from the time Drain Valve opened and the Inlet valve closed Turn Remote Control Off then On Reverts to (2) Green Flashes (7) Red Flashes Indicates Fault Code #7 Incorrect supply frequency Fan, Pump and Inlet Valve are turned OFF Power Supply frequency is not within 55 to 65 Hz for a period of time. Turn Remote Control Off then On Reverts to (2) Green Flashes Amber flashing Incorrect Remote Control address Cooler will not opperate Cooler does nor recognize Remote Control Re-Configure Remote for cooler Reverts to (2) Green Flashes

21 Quick Reference Guide Component Part Number EXT EXV EXH TBA TBS Volt Watts Capacitor Total Max Amps Motor Windings Resistance [Ω] (with Capacitior Disconnected) Orange/Brown Orange/Blue Grey/Black O / uf 8.4/ O / uf 8.4/ Orange/Blue Orange/Black Grey/Black O / uf O uf Motor Windings Resistance (Measured on Motor Cord Plug) O /1 750 Fan Motor O / Run/Com Run/Start Com/Start (Measured on Motor Cord Plug) Run Common Start Ground O / O / (Measured on pump Cord Plug) Tornado Pump O95851 EXT EXV 115/ O95905 EXH TBA TBS 230/ Ω 56.5 Ω

22 EA/EM RANGE 115v, 60hZ - Quick reference guide Component EA/EM Range part No. ohms with cap disconnected HP Amps Capacitor Fan Motor 2 Speed EA EM Motor with Pulley org-brn (aux) org-blu (main+aux) grey-blk (start) /3.2 30uf /5.6 30uf /5.6 30uf /7.1 40uf

23 EXV EXH(ICON) Setup Multiple Coolers with Remote Controls Cooler Number 1 Cooler Number 2 Turn Power on at CPMD Turn Power on at CPMD Within the first 4 minutes after power is applied to the CPMD install the batteries in the remote control Within the first 4 minutes after power is applied to the CPMD install the batteries in the remote control After 5 seconds the Remote control will display Id for 1 second After 5 seconds the Remote control will display Id for 1 second When the display 12:00 the Remote control is set and can be turned on. When the display 12:00 the Remote control is set and can be turned on. Before setting up the next cooler ensure that the power to cooler number 1 has been on for more that 5 minutes or you may shut off power to cooler # 1 at that the CPMD. This will ensure that the remote you are currently setting up will be recognized my the correct cooler. Additional Coolers Follow the steps for setting up cooler # 2 making sure that the power to previously set up coolers has either been on for more than 5 minutes or is turned off at the CPMD s PAGE 3

24 J-BOX EXH MODEL

25

26 FLOW CHARTS

27 FLOWCHART INDEX 1. SET UP OF HORIZON REMOTE CONTROL. EXV, EXH 2. SET UP MULTIPLE COOLERS WITH REMOTE CONTROLS. EXV, EXH 3. TROUBLESHOOTING HORIZON REMOTE CONTROL COMMUNICATION ISSUES. EXV, EXH 4. INITIAL SET UP OF HARMONY WIRED WALL CONTROL. EXV, EXH 5. ENTERING PARAMETER MODE USING HARMONY WIRED WALL CONTROL. EXV, EXH, TBA 6. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 OFF. EXH 7. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 ON. EXH 8. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF LESS THAN 10 MINUTES. EXH 9. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF MORE THAN 10 MINUTES. EXH 10. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 OFF. EXV 11. COOL FUNCTION TIMING SEQUENCE WITH HORIZON REMOTE CONTROL DIP SWITCH 4 ON. EXV 12. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF LESS THAN 10 MINUTES. EXV 13. COOL FUNCTION TIMING SEQUENCE WITH HARMONY WIRED WALL CONTROL, COOLER OFF MORE THAN 10 MINUTES. EXV 14. COOL FUNCTION TIMING SEQUENCE WITH SENSOR TOUCH WIRED WALL CONTROL, COOLER OFF LESS THAN 10 MINUTES. TBA 15. COOL FUNCTION TIMING SEQUENCE WITH SENSOR TOUCH WIRED WALL CONTROL, COOLER OFF MORE THAN 10 MINUTES. TBA 16. COMMUNICATION FAILURE HORIZON WIRELESS WALL CONTROL, FAULT CODE 1. EXV EXH 17. COMMUNICATION FAILURE WIRED WALL CONTROL, FAULT CODE 1. EXV EXH TBA 18. POWER INTERUPTION, FAULT CODE 8. EXV EXH TBA

28 EXV EXH(ICON) Set up of Horizon Remote Control Turn Power on at CPMD Within the first 4 minutes after power is applied to the CPMD install the batteries in the remote control If communication between the remote control and the cooler are not achieved After 5 seconds the Remote control will display Id for 1 second Check batteries or receiver and receiver cable at CPMD When the display goes blank again the Remote control is set and can be turned on. PAGE 1

29 EXV and EXH(ICON) Troubleshooting Horizon Remote control Communication Issues With main power to the cooler ON, when any button on the Horizon Remote is Pressed The Tri Color Led goes Steady state Green momentarily indicating CPMD has received proper signal and then returns to flashing green Remote Control is operating properly Fault code = 00 The Tri Color Led does not go Steady state Green momentarily but continues flashing green indicating no signal was received. Check Batteries, receiver and receiver connection Refer to Remote Control Setup Flowchart Fault code = 01 The Tri Color Led flashes Amber momentarily indicating CPMD address has not been set correctly and returns to flashing green Refer to Remote Control setup Flowchart. Note: Under normal operation the tri-color diagnostic led on the CPMD flashes green. PAGE 2

30 EXV and EXH(ICON) Initial Setup of Harmony Wall control Turn on power to CPMD Connect Harmony wall control to CPMD. Wall Control will show Service in the display. If the wall control display does not display service and communication between the wall control and the cooler has not been established Press and hold the down arrow for 9 seconds. The display will go Blank. Check Wall Control wiring and power to the CPMD The Wall control is now set up and can be turned on. PAGE 4

31 EXV, EXH(ICON) and TBA Entering parameter Mode using Wired Wall Control or IWC Turn OFF main power to unit for minimum of 6 seconds While still holding the AUTO button press the down button Turn ON main power to unit With wall control set to OFF Press and hold Auto for 3 seconds Minimum. Display should read A1 Param To change from Parameters A1-A9 or B1- B5 Press down button To View parameter value press AUTO Screen will display A# or B# and actual parameter value. To Change parameter value press up or down until desires parameter value is reached To exit parameter mode without saving changes press Power To Save changed parameters press auto, Display will return to A# Param screen Note: Entering Parameter mode can only be done within 4 minutes of main power being applied to CPMD. PAGE 5

32 EXH(ICON) MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to OFF Tank Empty Turn power on and insure Cooler is set to cool function Tank Full Fan starts Auto Drain Closes Pump Starts Fan Starts 9 second delay Solenoid turns on Tank fills, water reaches probes Note: When DIP switch # 4 on the bottom row in the Remote Control is set to OFF the cooler will not enter Pre-Cool when turned on. After 30 second delay Pump starts PAGE 6

33 EXH MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to ON Tank Empty Turn power on and ensure unit set to cool Tank Full Auto Drain Closes Pump Starts 9 second delay Fan starts at completion of Pre-cool Cycle Solenoid turns on Tank fills, water reaches probes After 30 second delay Note: When DIP switch # 4 on the bottom row in the Remote Control is set to ON the cooler will enter Pre-Cool each time it is turned on in Cool or changed from Vent to Cool. Pump starts Fan Starts at completion of Precool cycle PAGE 7

34 EXH Models Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for less than 10 minutes. Turn power on and ensure unit set to cool Tank Empty Fan starts. Auto Drain Closes Tank Full Pump Starts Fan Starts 9 second delay Solenoid turns on Tank fills, water reaches probes Note. When the cooler has been off for less than 10 minutes and was last set to Cool it will not enter Precool when turned back on. After 30 second delay Pump starts PAGE 8

35 TBA Model Cool Function Timing Sequence With Sensor Touch Wired Wall Control. *Cooler off for more than 10 minutes. Tank Empty Turn power on and ensure unit is set to Cool Tank Full Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Pump Starts Fan starts at completion of Precool Cycle Tank fills, water reaches probes Pump stops After 30 second delay Pump starts Fan starts at completion of Pre- Cool Cycle If water drops below probes for more than 12 seconds PAGE 15 Note. When the cooler has been off for more than 10 minutes it will enter a Pre- Cool cycle when turned on and set to Cool

36 EXH Model Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for more than 10 minutes. Tank Empty Turn power on and ensure unit is set to Cool Tank Full Auto Drain Closes Pump Starts 9 second delay Solenoid turns on Fan starts at completion of Precool Cycle Tank fills, water reaches probes After 30 second delay Note. When the cooler has been off for more than 10 minutes it will enter a Pre- Cool cycle when turned on and set to Cool Pump starts Fan starts at completion of Pre- Cool Cycle PAGE 9

37 EXV MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to OFF Tank Empty Turn power on and insure Cooler is set to cool function Tank Full Fan starts Auto Drain Closes 9 second delay Solenoid turns on Tank fills, water reaches probes After 30 second delay After 30 second delay Tank fills, water reaches probes Pump stops If water drops below probes for more than 12 seconds Pump Starts Fan Starts Note: When DIP switch # 4 on the bottom row in the Remote Control is set to OFF the cooler will not enter Pre-Cool when turned on. Pump starts PAGE 10

38 EXV MODELS Cool Function Timing Sequence with Horizon Remote Control * DIP switch 4 on Remote Control set to ON Tank Empty Turn power on and ensure unit set to cool Tank Full Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Pump Starts Fan starts at completion of Pre-cool Cycle Tank fills, water reaches probes After 30 second delay Pump starts Pump stops If water drops below probes for more than 12 seconds Note: When DIP switch # 4 on the bottom row in the Remote Control is set to ON the cooler will enter Pre-Cool each time it is turned on in Cool or changed from Vent to Cool. Fan Starts at completion of Precool cycle PAGE 11

39 EXV Models Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for less than 10 minutes. Turn power on and ensure unit set to cool Tank Empty Fan starts. Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Tank Full Pump Starts Fan Starts Tank fills, water reaches probes After 30 second delay Pump starts Pump stops If water drops below probes for more than 12 seconds PAGE 12 Note. When the cooler has been off for less than 10 minutes and was last set to Cool it will not enter Precool when turned back on.

40 EXV Models Cool Function Timing Sequence With Harmony Wired Wall Control. *Cooler off for more than 10 minutes. Tank Empty Turn power on and ensure unit is set to Cool Tank Full Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Pump Starts Fan starts at completion of Precool Cycle Tank fills, water reaches probes Pump stops After 30 second delay Pump starts Fan starts at completion of Pre- Cool Cycle If water drops below probes for more than 12 seconds PAGE 13 Note. When the cooler has been off for more than 10 minutes it will enter a Pre- Cool cycle when turned on and set to Cool

41 TBA Models Cool Function Timing Sequence With Sensor Touch Wired Wall Control. *Cooler off for less than 10 minutes. Turn power on and ensure unit set to cool Tank Empty Fan starts. Auto Drain Closes 9 second delay Solenoid turns on After 30 second delay Tank fills, water reaches probes Tank Full Pump Starts Fan Starts Tank fills, water reaches probes After 30 second delay Pump starts Pump stops If water drops below probes for more than 12 seconds PAGE 14 Note. When the cooler has been off for less than 10 minutes and was last set to Cool it will not enter Precool when turned back on.

42 HORIZON WIRELESS WALL CONTROL Fault Code 1 Communication Failure Green LED changes to red and gives 1 red flash This happens when the CPMD loses communication with the Horizon Wireless Wall Control for 30 minutes or more. Horizon Wireless Wall Control has been moved out of range of receiver, or signal is being blocked by an obstruction Weak or low batteries in Wall Control. Problem with Receiver, or Receiver cable. Move remote closer to location of receiver. Cooler will resume operation in 2 to 10 minutes. Replace batteries with new alkaline type (AAA). Turn cooler on using wall control to resume operation PAGE 16 Replace Receiver or Cable Turn cooler on using wall control to resume operation

43 WIRED WALL CONTROL Fault Code 1 Communication Failure Green LED changes to red and gives 1 red flash This happens when the CPMD loses communication with the Harmony Wall Control for 10 seconds or more Harmony Wall control disconnected. Reconnect Wall Control and manually restart cooler using wall control. If cooler indicates Service on display clear service indication by holding down arrow for 10 seconds. And restart cooler. Defective Wall Control. Replace Wall Control and clear service indication by holding down arrow for 10 seconds. Restart cooler with Wall Control Cable from CPMD to Harmony Wall Control damaged. Replace Cable. Clear Service indication by holding down arrow for 10 seconds. Restart cooler with Wall Control PAGE 17

44 POWER INTRUPTION FAULT CODE 8 COOLER SHUTS OFF UNEXPECTEDLY Power Interruption for less than 5 seconds Power Interruption for more than 5 seconds Wired Wall Control Wireless Wall Control Wired Wall Control Wireless Wall Control Cooler will restart once power resumes Cooler will restart in 2 to 10 minutes after power resumes Cooler will require a manual restart using wall control Cooler will restart in 2 to 10 minutes after power resumes PAGE 18

45 NOTES..

46 1002 S 56 Ave Suite 101 Phoenix AZ Ph Fax

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EXH, EZH) Introduction...4 Remote Thermostat Control...5 Wall Mounted Thermostat Control...11

More information

OWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EA, EXH, EZH) Hello and congratulations on purchasing a Breezair Ducted Cooler for your home.

More information

Wall Controller & Thermostat

Wall Controller & Thermostat Wall Controller & Thermostat Thank you for purchasing a Genuine component from Seeley International. This Wall Controller has been engineered and manufactured to the highest standard to maximise the performance

More information

REMOTE CONTROL FAN SPEED ECONOMY BATTERY LOW. owner s manual

REMOTE CONTROL FAN SPEED ECONOMY BATTERY LOW. owner s manual REMOTE CONTROL AUTO FAN SPEED COOL PM ECONOMY BATTERY LOW owner s manual Hello and congratulations on purchasing a Breezair Ducted Cooler for your home. Breezair coolers have been designed to provide quiet,

More information

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A INSTALLATION MANUAL TBA Evaporative Cooler ILL1456-A (English) (TBA) TIMER AUTO COOL ILL1128-A ILL239-D TIMER AUTO COOL ILL1128-A ILL972-A Step 1 Step 2 Step 3 Step 4 SAFETY FIRST! 1. Read & understand

More information

INSTALLATION MANUAL TBA Evaporative Cooler

INSTALLATION MANUAL TBA Evaporative Cooler INSTALLATION MANUAL TBA Evaporative Cooler (English) (TBA) INDEX CABLE LENGTHS, STANDARD WALL CONTROL........................................ 2 COOLER COMPONENTS.............................................................

More information

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English) OWNER S MANUAL EXQ / EZQ / EXS Evaporative Coolers (English) Original English Instructions Hello and congratulations on purchasing a Breezair evaporative cooler for your home. At Seeley International

More information

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications EnviroMagic Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications World leading climate control solutions Seeley International is Australia s largest air conditioning

More information

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM) OWNER S MANUAL Evaporative Cooler (English) (LCB, CPL, CPS, BM) Original English Instructions TABLE OF CONTENTS INTRODUCTION 4 WALL CONTROL FUNCTIONS 5 STARTING YOUR COOLER 5 AUTOMATIC MODE 6 MANUAL MODE

More information

Safety / Kit Components 1

Safety / Kit Components 1 Installation & Operation Manual Industrial Wall Control IWC0 (incorporating SmartHub and Fault Indicating features) Safety / Kit Components SAFETY Please read this manual carefully. Your failure to do

More information

WV Series Evaporative Cooler. Installation Manual

WV Series Evaporative Cooler. Installation Manual WV Series Evaporative Cooler Installation Manual Index 1 INDEX Safety Instructions...1 General Instructions...1 Installation Details...2 Water Installation...4 Electrical Installation...5 Wiring Diagrams...5

More information

Spectrolink Comfort Control. Home Owner's Manual Heating

Spectrolink Comfort Control. Home Owner's Manual Heating Spectrolink Comfort Control Home Owner's Manual Heating Heater identification and installation Model No: Serial No: Installation date: Installer: Installer phone No: This information is to be completed

More information

Brivis Service Manual

Brivis Service Manual Brivis Service Manual Evaporative Cooler AD/C 5 Series N-E1 & Tekelek 461 1999 Supplement This manual is to be used in conjunction with the Service Manual 12 - Cooler - AD / CC (series 4 & 5) Service Manual

More information

INSTALLATION MANUAL EA Evaporative Cooler

INSTALLATION MANUAL EA Evaporative Cooler INSTALLATION MANUAL EA Evaporative Cooler (English) (EA) Down Discharge Side Discharge INDEX Safety Instructions...1 General Instructions...1 Installation Details...2 Water Installation...4 Electrical

More information

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS Domestic Washer Technical Information 120 V, 60 Hz Models SAV2555AW* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.

More information

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10 IJ3000 IJ3000 Flushing System 5760-029N Revision B Installation Instructions Page 1 of 10!! WARNING: Do not turn on until all plumbing and electrical connections have been made. WARNING: The flushing system

More information

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating HOME OWNER S MANUAL Spectrolink Comfort Control - Heating (English)(623528k) HEATING HEATER IDENTIFICATI AND INSTALLATI Model No: Serial No: Installation date: Installer: Installer phone No: This information

More information

TECHNICAL INFORMATION T 15xx Dryers

TECHNICAL INFORMATION T 15xx Dryers TECHNICAL INFORMATION T 15xx Dryers 2010 Miele USA Table of Contents 1.0 2.0 3.0 T 15xx Dryers Construction and Design... 5 1.1 Appliance Overview Vented Models... 5 1.2 Appliance Overview Condenser Models...

More information

Commercial and Industrial Cooling. World-leading natural cooling technology

Commercial and Industrial Cooling. World-leading natural cooling technology Commercial and Industrial Cooling World-leading natural cooling technology Why Breezair? How evaporative air conditioning works The beauty of evaporative air conditioning is its simplicity. It s a process

More information

TECHNICAL INFORMATION T1500 Series Clothes Dryers

TECHNICAL INFORMATION T1500 Series Clothes Dryers TECHNICAL INFORMATION T1500 Series Clothes Dryers 2003 Miele - Table of Contents 1.0 CONSTRUCTION & DESIGN 1.1 Appliance Overview - Vented 1 1.2 Appliance Overview Condenser Models 2 1.3 Controls Overview

More information

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030 Technical Training Prodigy Undercounter Cubers Models CU1526, CU2026 and CU3030 List of Major Topics Introduction Installation Operation Maintenance Diagnosis Service Prodigy with a Bin 3 models CU1526

More information

Brivis Service Manual

Brivis Service Manual ISO Documents Last modified by: Felicity Devine Date last modified: 23/02/2005 Document: Brivis Service Manual Evaporative Cooler Contour N-E3 & BC-E1 1999 Supplement This manual is to be used in conjunction

More information

Mobile Evaporative Cooler

Mobile Evaporative Cooler The Breezair Mobile Evaporative Cooler EA120SVM Motionless, stale air and high temperatures commonly found in a variety of places can have an adverse effect on morale, production and productivity. By reducing

More information

INSTALLATION MANUAL. CPL CPS LCB BM Evaporative Cooler. (English) (CPL CPS LCB BM) (Original English Instructions) ILL1456-A

INSTALLATION MANUAL. CPL CPS LCB BM Evaporative Cooler. (English) (CPL CPS LCB BM) (Original English Instructions) ILL1456-A INSTALLATION MANUAL CPL CPS LCB BM Evaporative Cooler ILL1456-A (English) (CPL CPS LCB BM) (Original English Instructions) WARNING: Failure to install and commission the product in compliance with these

More information

INSTRUCTION MANUAL. FOR MODELS MobileMAX II & MobileMAX III High Performance Mobile Evaporative Coolers

INSTRUCTION MANUAL. FOR MODELS MobileMAX II & MobileMAX III High Performance Mobile Evaporative Coolers INSTRUCTION MANUAL FOR MODELS II & III High Performance Mobile Evaporative Coolers 1. Safety Instructions 2. Assembly 3. Features 4. Operation 5. Maintenance 6. Replacement Parts 7. Troubleshooting Read

More information

WC Series Vended Washers Troubleshooting, and Fault Codes

WC Series Vended Washers Troubleshooting, and Fault Codes WC Series Vended Washers Troubleshooting, and Codes 1 Common Troubleshooting s Symptom Probable Cause Suggested Remedy 2 Machine does not start Machine will not accept and count coins Door does not lock

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

Auto Drain Installation Instructions.

Auto Drain Installation Instructions. Kit No 077444 Auto Drain Installation Instructions. TO SUIT RPC- RPA - RPB 2 SPEED ONLY 2 8 9 3 9 6 4 7 5 2 3 4 5 40 Drain valve. 63864 Pcb. (Inside control box.) 8338 Probe. 638843 Brkt Large. RPB 200-800

More information

OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS

OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS R O O F T O P N A T U R A L A I R C O N D I T I O N E R S OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS How to Operate Using Your Air Conditioner

More information

OWNER S MANUAL. CPL Evaporative Cooler. (English) (CPL) ILL1456-A

OWNER S MANUAL. CPL Evaporative Cooler. (English) (CPL) ILL1456-A OWNER S MANUAL CPL Evaporative Cooler ILL1456-A (English) (CPL) 2 Introduction 3 Wall Control Functions 7 Drain Valve & Bleed System 8 Maintenance 10 Troubleshooting 1 CPL Evaporative Cooler INTRODUCTION

More information

Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R

Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R baby, cold i s t outside Spectrolink Comfort Controller Home Owner's Manual Heating 2006 Come home to ECOST R SERVICE: 1300 650 644 For all your Braemar warranty and service needs. Or Contact your local

More information

Model 1820 Dehumidifier

Model 1820 Dehumidifier Model 1820 Dehumidifier Installation Instructions SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing.

More information

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01 Owner s Manual Keep with machine for reference GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01 CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895- 2141 www.cmadishmachines.com

More information

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00 Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com

More information

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance. WARNING: Warning devices are strictly! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren

More information

REPAIR PART DIAGRAMS. Pages: 1-6

REPAIR PART DIAGRAMS. Pages: 1-6 REPAIR PART DIAGRAMS PRODUCT: MODEL: DISHWASHER LL S The information included in this Ariston Spare Parts List may change without notice please see our web site www.usservicenet.com for updates, corrections

More information

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE

More information

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION: RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY Voltage Measurement Safety Information When performing live voltage measurements, you must do the following: Verify the controls are in the off position so that the appliance does not start when energized.

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 Owner s Manual Keep with machine for reference PKC24 INSTALLATION & OPERATION REV.11.09 Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223 800-558- 5592 FAX 414-353- 7069 perlick.com TABLE OF

More information

Breezair RPA Series Installation Manual

Breezair RPA Series Installation Manual Breezair RPA 400-1500 Series Installation Manual Table of Contents ITEM Employer and Employee Responsabilities Introduction Location of Air Conditioner Installation Guidelines Products Specification Flexible

More information

Auto Drain Installation Instructions.

Auto Drain Installation Instructions. Kit No 077444 Auto Drain Installation Instructions. TO SUIT RPC- RPA - RPB - AL COOLERS 1 2 8 9 3 9 6 4 7 5 1 2 3 4 5 114101 Drain valve. 638614 Pcb. (Inside control box.) 833811 Probe. 638843 Brkt Large.

More information

OWNER S MANUAL LCQ / LCS / LCQI / BMQ / CPQ TBQ / TBS / TBQI / TBSI Evaporative Cooler

OWNER S MANUAL LCQ / LCS / LCQI / BMQ / CPQ TBQ / TBS / TBQI / TBSI Evaporative Cooler OWNER S MANUAL LCQ / LCS / LCQI / BMQ / CPQ TBQ / TBS / TBQI / TBSI Evaporative Cooler (English) Original English Instructions LCQ / LCS / LCQI / BMQ / CPQ / TBQ / TBS / TBQI / TBSI OWNER S MANUAL 1 IMPORTANT

More information

PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F ,137,215, 232,

PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F ,137,215, 232, PARTS LIST ALPHABETICAL ALL FROSTY FACTORY MODELS Rev 06/12/2014 Description Item No. Used on models Price Bearing, Flywheel F0267 115,137,215, 232, 237 43.15 Bearing, Motor,Frt.Coupling F0427 113,117,127,217

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System Technical Bulletin AD-1272 Code No. LIT-12012477 Issued December 2017 Refer to the QuickLIT website for the most up-to-date version of

More information

Portable Evaporative Cooling System

Portable Evaporative Cooling System Portable Evaporative Cooling System User s Manual Manufactured by HH Technologies, Inc. 1733 County Road 68 Bremen, Alabama 35033 256-287-7000 Part No 4801-5035 Rev 03-2017 User s Manual PolarCool Table

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

ivector HEATER/COOLER 2 AND 4-PIPE MODELS. 25278 ivector Installation Guide US 02/01/2013 09:24 Page 2 ivector HEATER/COOLER 2 AND 4-PIPE MODELS. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL JANUARY 2013, ISSUE 1 Product Serial Number:

More information

OWNERS INSTRUCTION MANUAL

OWNERS INSTRUCTION MANUAL P O R T A B L E N A T U R A L A I R C O N D I T I O N E R S OWNERS INSTRUCTION MANUAL MEGACOOL MASTERCOOL MILLENIA C O O L A I R A N Y W H E R E! by 1 PORTABLE EVAPORATIVE AIR COOLER - IMPORTANT SAFETY

More information

TECHNICAL INFORMATION Touchtronic Clothes Dryers

TECHNICAL INFORMATION Touchtronic Clothes Dryers TECHNICAL INFORMATION Touchtronic Clothes Dryers Includes: T1302, T1303, T1322, T1329ci T1403 & T1405 2004 Miele This page intentionally left blank. Table of Contents GENERAL INFORMATION A. Warning and

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

ACE. HydroStream Model HC-100. Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications...

ACE. HydroStream Model HC-100. Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications... AC E Air Cleaning Equipment Inc 303 N Main St Broadway NC 27505 800-962-0650 www.industrialairtreatment.com Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications...

More information

Operation and Maintenance Manual 120V/60HZ

Operation and Maintenance Manual 120V/60HZ Operation and Maintenance Manual 120V/60HZ GLACIER CS5-16-VD CS5-16-VD-TB CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Operation & Maintenance Manual 60HZ Models Table of Contents:

More information

WSK300 Multifunction Wall Control

WSK300 Multifunction Wall Control WSK300 Multifunction Installation & Operating Instructions WARNING Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: Installation and

More information

Smart-Wall TV Kit - Installation & Operation Instructions -

Smart-Wall TV Kit - Installation & Operation Instructions - If any parts are missing or damaged, contact your Dealer before starting installation. DO NOT install a damaged kit. Be sure to also reference the appliance Installers Guide. Approvals The flexible duct

More information

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS. PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

385 SERIES REMOTE HANDHELD SIREN ETSA385HR ! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren sound outside of vehicle. Please

More information

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00 Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 F A X 7 1 4-8 9 5-2141 www.cmadishmachines.com

More information

Model Series Series

Model Series Series PumpAgents.com - Click here for Pricing/Ordering Model 36800-Series 36900-Series ELECTRIC WATER SYSTEM PUMPS Automatic Multi-Outlet FEATURES Self-Priming Diaphragm Design Allows Dry Running Built-in Discharge

More information

380 SERIES REMOTE SIREN ETSA380R

380 SERIES REMOTE SIREN ETSA380R ! WARNING Sirens produce loud sounds that may damage hearing: - Roll up windows. - Wear hearing protection. - Use only for emergency response. - Avoid exposure to siren sound outside of vehicle. Please

More information

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting

More information

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501 Contents FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501 INTRODUCTION... 1 BASIC OPERATION... 2 SYSTEM OVERVIEW... 3 OPERATOR CONTROLS AND DISPLAY PANEL... 4 & 5 DUAL BUTTON

More information

UF424 and UN324. Technical Service

UF424 and UN324. Technical Service UF424 and UN324 Technical Service Technical Service 1-800-533-6006 Check out the new mobile ready website www.scotsman-ice.com/service Technical Service Virtual Business Card What you will learn Introduction

More information

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Model No.: PS08-01 PS10-01 Ref: KY80 KY100 8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable

More information

BIX B-One 100 kw INSTALLATION GUIDE

BIX B-One 100 kw INSTALLATION GUIDE BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality.

More information

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location

More information

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts you to potential hazards or unsafe practices which,

More information

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL Crypto-Lock Model CC-8521B Updated 7/17 Access Control System INSTRUCTION MANUAL MONITEQ, Inc. 2 TABLE OF CONTENTS 1. INTRODUCTION..4 2. SPECIFICATIONS.....6 3. SUPPLIED EQUIPMENT.. 6 4. FUNCTIONS OF CONTROLS

More information

DISHWASHER - PART RECOGNITION GUIDE

DISHWASHER - PART RECOGNITION GUIDE DISHWASHER - PART RECOGNITION GUIDE SPRAY ARM HOLDER UPPER SPRAY ARM FILTER ASSEMBLY LOWER SPRAY ARM ASSEMBLY SUMP DISHWASHER - PART RECOGNITION GUIDE DISPENSER DOOR SPRING DOOR HINGE INNER DOOR DOOR THERMOSTAT

More information

TECH SHEET - DO NOT DISCARD PAGE

TECH SHEET - DO NOT DISCARD PAGE TECH SHEET - DO NOT DISCARD PAGE 1 3. If this test mode has been entered successfully, all indicators on the console are illuminated for 5 seconds with 8:88 showing in the Estimated Time Remaining three-digit

More information

AGP. (All Grade Pellet) Troubleshooting Guide Document Copyright 2017 Travis Industries Certified Factory Training Program

AGP. (All Grade Pellet) Troubleshooting Guide Document Copyright 2017 Travis Industries Certified Factory Training Program AGP (All Grade Pellet) Troubleshooting Guide Document 176-01795 Copyright 2017 Travis Industries Certified Factory Training Program The unit has been programmed to evacuate smoke in case of a power failure.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

CaterSense 03 & ATSC-02-xx

CaterSense 03 & ATSC-02-xx CaterSense 03 & ATSC-02-xx GAS SUPPLY INTER-LOCK STATION with INBUILT FAN SPEED CONTROL & CO 2 MONITORING (Optional Gas Pressure Proving) INSTALLATION and COMMISSIONING INSTRUCTIONS CS-ATSC-INST-CO2 Page

More information

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts. BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Product Manual SZ1009

Product Manual SZ1009 Product Manual SZ1009 Conventional Heating & Cooling Thermostats with Heat Pump Mode Communicating Thermostats Description The SZ1009 is a microprocessor-based mable thermostats designed for conventional

More information

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners Operation Manual PortaPac 5-, 8 and 10-ton Portable Air Conditioners A AirPac, Incorporated AirPac Technology Park 888 Shenandoah Shores Road Front Royal, Virginia 22630 U.S.A. Toll Free 888-324-7722 Web:

More information

MPT Electric Fire Pump Controller

MPT Electric Fire Pump Controller MPT Electric Fire Pump Controller Alarm Messages and Guide This manual provides alarm descriptions, troubleshooting steps, and alarm set point configuration information for Metron MPT Fire Pump Controllers

More information

Scotsman Technical Training. CU50 Cube Ice Machine

Scotsman Technical Training. CU50 Cube Ice Machine Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

Owner s Manual RD432-0 Chemical Controller

Owner s Manual RD432-0 Chemical Controller Owner s Manual RD432-0 Chemical Controller Table of Contents I. Introduction page 2 A. Water Chemistry page 2 B. Safety page 3 C. System Components page 4 D. Specifications page 7 E. Controller Panel Descriptions

More information

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English) ILL1672-A

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English) ILL1672-A OWNER S MANUAL EXQ / EZQ / EXS Evaporative Coolers ILL1672-A (English) Original English Instructions IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING - TO REDUCE

More information

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ Operation & Maintenance Manual Table of Contents: 1.0 Introduction 1 2.0 Unpacking your COOL- SPACE 1 3.0 Set-up

More information

CAC series Portable Air-Cooled Spot Cooler

CAC series Portable Air-Cooled Spot Cooler CAC series Portable Air-Cooled Spot Cooler ENGINEERING, INSTALLATION AND SERVICE MANUAL Form EISM-CAC 030115 Rev 1 TABLE OF CONTENTS PAGE GENERAL INFORMATION... 1 PRODUCT DATA AND SPECIFICATIONS... 2 UNIT

More information

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER INSTRUCTIONS FOR TAL SERIES VACUUM HOR LOADER TAL-15U 150 LBS PER HOUR MAGNETIC LEVEL SWITCH TAL-3U-E 450 LBS PER HOUR SIGHT GLASS WITH PROXIMITY LEVEL SWITCH Proportional Dual Feed Valve Available TAL-6U

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

Thermo 50 Coolant Heater. HMMWV 6.2 and 6.5 Liter Diesel. Table of Contents. Foreword

Thermo 50 Coolant Heater. HMMWV 6.2 and 6.5 Liter Diesel. Table of Contents. Foreword Thermo 50 Coolant Heater HMMWV 6. and 6.5 Liter Diesel Special instructions for these models Part locations may differ slightly dependent on the vehicle model. Table of Contents Foreword Parts List 3 Vehicle

More information

INDEX D1976 DISHWASHER (DW955)

INDEX D1976 DISHWASHER (DW955) 1 INDEX D1976 DISHWASHER (DW955) PROGRAMS 2 ELECTRICAL FUNCTIONS 6 PART NUMBER SUFFIX DEFINITIONS 8 SPARE PARTS LIST Casing and related parts 10 Container and related parts 12 Door 14 Control Panel 16

More information

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL Firefly II Multi Voltage RELEASE DEVICES Firefly II & IIB-MV INSTALLATION MANUAL GENERAL DESCRIPTION: S/N The The Cookson Company Firefly II-MV time delay release devices are designed for use on rolling

More information

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing

More information

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service

HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service HID312, HID525 and HID540 Meridian Ice Maker-Dispensers Technical Service What you will learn Introduction Installation Operation Maintenance Take It Apart Diagnostics HID Ice Maker-Dispensers HID models

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY F SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform

More information

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL RELEASE DEVICES MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL The LiftMaster Fire Control (LM21-AFC) Release Device/Control Panel is UL/CUL listed normally energized fail-safe device incorporating

More information