1 ISO Documents Last modified by: Felicity Devine Date last modified: 23/02/2005 Document: Brivis Service Manual Evaporative Cooler Contour N-E3 & BC-E Supplement

2 This manual is to be used in conjunction with the Service Manual 14 issue 4 - Cooler - Contour Series, and for reference to Tekelek wall controls, Service Manual 12 - Cooler - AD / CC (series 4 & 5).

3 Index Pages Page 2 INTRODUCTION: TECHNICAL INFORMATION SHEETS: Contour Classic L Contour Classic L Contour Classic L Contour Classic L Contour Classic L CONTOUR BC-E1 MODEL MOTOR CIRCUIT DIAGRAM MOTOR & FAN IMPELLOR MOUNTING COOLER OPERATION N-E3 MODELS Module Upgrade & Parameter Variations Prewetting the Filter Pads Tekelek 425 Auto Mode Operation Sequence Pump Flush N-E3 WATER MANAGEMENT SYSTEM COOLER OPERATION BC-E1 MODELS: General Operation Flush Service Operation Fan Operation Electronic Control Module Operation ABNORMAL OPERATION: Trident Water Management System Fan Motor Lockout

4 Page 3 Contour Cooler N-E3 & BC-E1 Model Supplement Introduction This manual is to be used in conjunction with the Service Manual 14 issue 4 - Cooler - Contour Series, and for reference to Tekelek wall controls, Service Manual 12 - Cooler - AD / CC (series 4 & 5). The supplement deals with the different functions of the current Contour (Midline & Premium) model range with the new N-E3 module, and the introduction of the new base model Contour Cooler (Classic & Midline) using the new BC-E1 module. The N-E3 and BC-E1 modules both locate in the Contour Cooler cabinet in the same position and type of housing used for the N-E2 module. The Classic Contour will not be available with the Networker wall control, Servoseal and drain valve (dump), fan motor speed sensor, or wash cycle operation. Classic Contour will retain the Trident Water Management system, Water Inlet Solenoid filling, and use the Tekelek 485 (manual) wall control. Other Contour features have also been maintained such as, Pre-Wet, Pump Back Flush, Flush Service, & DC Brake, however, the functions and timing have varied from the N-E2 module. Because the BC-E1 module has no facility to handle the Networker, there are no Networker installer or service set up parameters. Servicing and diagnostic procedures are the same, as per the Service Manual - Contour series, except some functions do not a apply for the BC-E1, and some defaults and parameter values have changed. As Classic models have had the Servoseal deleted from the cabinet design, a new variation of the Winter Seal will be available as an

5 option. The Midline Contour (N-E3 module) range will now be available with either the Tekelek 425 (Auto) or the Tekelek 485 (Manual) wall control. Note: The Tekelek 425 wall control also performs a Pre-Wet function.

6 Technical Information Contour L10 Sizing Guide Reference Figure Cabinet detail Page 4 Width Height front Height back Length Dry Weight Wet Weight 960 mm 740 mm 430 mm 960 mm 46 kg 56 kg Filter Pad Details Down Quantity 4 Thickness 75 mm Type CELDEK Duct Outlet Size Width Length Down 550 mm 550 mm Motor Pump/Water Distribution Type 240 V - 1 ph Type Askoll Model Betts Rating 240 V /.22 Amps 855BNVA-A12 Capacity 20 L/minute Watts 315 Overflow size 40 mm Amps 2.8 Waste Outlet Size 40 mm R.P.M Tank Capacity 10 Litres Capacitor Size 8 uf Coil Resistance 169 OHM N-E3 R.P.M Min Setting 500 Distribution Hose Size 20 mm CLEAR HOSE N-E3 R.P.M Max Setting 1450 Inlet Valve Type Tech/Comp S/Soft AH50 N-E3 Model Selection # Model 7 Inlet Valve Size 3/4" BSP (Male) Thread BC-E1 Model Selection # 1 - Bridge ON Inlet Valve Rating 240 V Amps Inlet Valve Capacity 12 L/min Fan Impellor ServoSeal Motor - N-E3 Models Only Size 485 mm Rating 240 V 50 Hz 0.23W Types AUSWING 92 RPM 500 Blades 5 Resistor 100n/f Blade Angle 25 deg TIP Capacitor 470 Ohm Cooler Control Module BC-E1 Wall Control TEKELEK 485 (Manual) N-E3 Networker TEKELEK 485 (Manual) TEKELEK 425 (Electronic) Water Connection

7 Flexible Hose Connection with 1/2" BSP Thread Drain Connection 40 mm PVC

8 Technical Information Contour L20 Sizing Guide Reference Figure Cabinet detail Page 5 Width Height front Height back Length Dry Weight Wet Weight 960 mm 740 mm 430 mm 960 mm 46 kg 56 kg Filter Pad Details Down Quantity 4 Thickness 90 mm Type CELDEK Duct Outlet Size Width Length Down 550 mm 550 mm Motor Pump/Water Distribution Type 240 V - 1 ph Type Askoll Model Betts Rating 240 V /.22 Amps 855BQVA-A14 Capacity 20 L/minute Watts 750 Overflow size 40 mm Amps 5.7 Waste Outlet Size 40 mm R.P.M Tank Capacity 10 Litres Capacitor Size 25 uf Coil Resistance 169 OHM N-E3 R.P.M Min Setting 500 Distribution Hose Size 20 mm CLEAR HOSE N-E3 R.P.M Max Setting 1450 Inlet Valve Type Tech/Comp S/Soft AH50 N-E3 Model Selection # Model 7 Inlet Valve Size 3/4" BSP (Male) Thread BC-E1 Model Selection # 1 - Bridge ON Inlet Valve Rating 240 V Amps Inlet Valve Capacity 12 L/min Fan Impellor ServoSeal Motor - N-E3 Models Only Size 485 mm Rating 240 V 50 Hz 0.23W Types AUSWING 92 RPM 500 Blades 10 Resistor 100n/f Blade Angle 25 deg TIP Capacitor 470 Ohm Cooler Control Module BC-E1 Wall Control TEKELEK 485 (Manual) N-E3 Networker TEKELEK 485 (Manual) TEKELEK 425 (Electronic) Water Connection Flexible Hose Connection with 1/2" BSP Thread

9 Drain Connection 40 mm PVC Technical Information Contour L30 Sizing Guide Reference Figure Cabinet detail Page 6 Width Height front Height back Length Dry Weight Wet Weight 1060 mm 800 mm 480 mm 1060 mm 52 kg 64.5 kg Filter Pad Details Down Quantity 4 Thickness 75 mm Type CELDEK Duct Outlet Size Width Length Down 550 mm 550 mm Motor Pump/Water Distribution Type 240 V - 1 ph Type Askoll Model Betts Rating 240 V /.22 Amps 855BQVA-A14 Capacity 20 L/minute Watts 750 Overflow size 40 mm Amps 5.7 Waste Outlet Size 40 mm R.P.M Tank Capacity 10 Litres Capacitor Size 25 uf Coil Resistance 169 OHM N-E3 R.P.M Min Setting 500 Distribution Hose Size 20 mm CLEAR HOSE N-E3 R.P.M Max Setting 1150 Inlet Valve Type Tech/Comp S/Soft AH50 N-E3 Model Selection # Model 3 Inlet Valve Size 3/4" BSP (Male) Thread BC-E1 Model Selection # 1 - Bridge ON Inlet Valve Rating 240 V Amps Inlet Valve Capacity 12 L/min Fan Impellor ServoSeal Motor - N-E3 Models Only Size 485 mm Rating 240 V 50 Hz 0.23W Types AUSWING 92 RPM 500 Blades 10 Resistor 100n/f Blade Angle 33 deg TIP Capacitor 470 Ohm Cooler Control Module BC-E1 N-E3 Wall Control TEKELEK 485 (Manual) Networker TEKELEK 485 (Manual)

10 Water Connection Flexible Hose Connection with 1/2" BSP Thread Drain Connection 40 mm PVC TEKELEK 425 (Electronic)

11 Technical Information Contour L40 Sizing Guide Reference Figure Cabinet detail Page 7 Width Height front Height back Length Dry Weight Wet Weight 1060 mm 800 mm 480 mm 1060 mm 52 kg 64.5 kg Filter Pad Details Down Quantity 4 Thickness 90 mm Type CELDEK Duct Outlet Size Width Length Down 550 mm 550 mm Motor Pump/Water Distribution Type 240 V - 1 ph Type Askoll Model Betts Rating 240 V /.22 Amps 855BQVA-A14 Capacity 20 L/minute Watts 750 Overflow size 40 mm Amps 5.7 Waste Outlet Size 40 mm R.P.M Tank Capacity 10 Litres Capacitor Size 25 uf Coil Resistance 169 OHM N-E3 R.P.M Min Setting 500 Distribution Hose Size 20 mm CLEAR HOSE N-E3 R.P.M Max Setting 1350 Inlet Valve Type Tech/Comp S/Soft AH50 N-E3 Model Selection # Model 1 Inlet Valve Size 3/4" BSP (Male) Thread BC-E1 Model Selection # 1 - Bridge OFF Inlet Valve Rating 240 V Amps Inlet Valve Capacity 12 L/min Fan Impellor ServoSeal Motor - N-E3 Models Only Size 533 mm Rating 240 V 50 Hz 0.23W Types AUSWING 92 RPM 500 Blades 10 Resistor 100n/f Blade Angle 33 deg TIP Capacitor 470 Ohm Cooler Control Module BC-E1 N-E3 Wall Control TEKELEK 485 (Manual) Networker TEKELEK 485 (Manual) TEKELEK 425 (Electronic) Water Connection

12 Flexible Hose Connection with 1/2" BSP Thread Drain Connection 40 mm PVC

13 Technical Information Contour L50 Sizing Guide Reference Figure Cabinet detail Page 8 Width Height front Height back Length Dry Weight Wet Weight 1060 mm 800 mm 480 mm 1060 mm 52 kg 64.5 kg Filter Pad Details Down Quantity 4 Thickness 110 mm Type CELDEK Duct Outlet Size Width Length Down 550 mm 550 mm Motor Pump/Water Distribution Type 240 V - 1 ph Type Askoll Model Betts Rating 240 V /.22 Amps 855BQVA-A14 Capacity 20 L/minute Watts 750 Overflow size 40 mm Amps 5.7 Waste Outlet Size 40 mm R.P.M Tank Capacity 10 Litres Capacitor Size 25 uf Coil Resistance 169 OHM N-E3 R.P.M Min Setting 500 Distribution Hose Size 20 mm CLEAR HOSE N-E3 R.P.M Max Setting 1350 Inlet Valve Type Tech/Comp S/Soft AH50 N-E3 Model Selection # Model 1 Inlet Valve Size 3/4" BSP (Male) Thread BC-E1 Model Selection # 1 - Bridge OFF Inlet Valve Rating 240 V Amps Inlet Valve Capacity 12 L/min Fan Impellor ServoSeal Motor - N-E3 Models Only Size 533 mm Rating 240 V 50 Hz 0.23W Types AUSWING 92 RPM 500 Blades 10 Resistor 100n/f Blade Angle 33 deg TIP Capacitor 470 Ohm Cooler Control Module BC-E1 N-E3 Wall Control TEKELEK 485 (Manual) Networker TEKELEK 485 (Manual) TEKELEK 425 (Electronic) Water Connection

14 Flexible Hose Connection with 1/2" BSP Thread Drain Connection 40 mm PVC

15 Contour BC-E1 Model Page 9 MAINS SUPPLY WATER INLET SOLENOID FAN MOTOR A N RUN START COMMON N TEK 485 Models Select Flush Select 20 - Bridge ON ( Default) 10 - Bridge OFF E CAPACITOR A N BCE-1 TRIDENT WATER MANAGEMENT SYSTEM PUMP

16 Motor Circuit Diagram Page 10 MOTOR WIRING CIRCUIT DIAGRAM BETTS 855 BNVA - A12 MOTOR WATT DIRECT WIRED BLUE(COMMON) BLACK (START) BROWN GREEN /YELLOW EARTH OVERLOAD START 38.8 MAIN 10.6 Capacitor - 8 uf

17 Motor Circuit Diagram MOTOR WATT DIRECT WIRED BETTS MODEL - 855BQVA - A14 Page 11 BLUE(COMMON) BLACK (START) BROWN (RUN) GREEN /YELLOW EARTH OVERLOAD START 9.6 MAIN 4.4 CAPACITOR 25 u/f

18 Technical Information Motor and Fan Impellor Mounting Contour Coolers Page 12 Impellor Hub Bracket positioned at top of motor shaft Fan Impellor Motor Motor Bracket 45mm Motor End Plate Motor Bracket positioned 45mm above motor end plate

19 Cooler Operation N-E3 Models Module Upgrade and Parameter Variations The new N-E3 module Contours operate the same functions as the previous N-E2 module, however, some of the parameter value and default settings have been modified. The main change is an additional connection terminal to accept the Tekelek wall control. Page 13 MOTOR SPEED SENSOR LOOM NETWORKER LOOM Tekelek Wall Control Loom Plug WATER LEVEL CONTROL LOOM ALTERNATIVE NETWORKER CONNECTION POINT J 2 J 1 J 6 J 5 J 3 N-E3 Module Contour Coolers with this control may be purchased with either the Tekelek 425 (Auto) or Tekelek 485 (Manual) wall controls, or the Networker. The operation of the Cooler using the Tekelek 485 or the Tekelek 425 in manual mode is the same as for the Networker manual mode i.e. Pre-Wet. Note: A special version Tekelek 485 wall control with a maximum speed set potentiometer is available for Service Technicians. The potentiometer is clearly marked on the back of the control PCB,

20 the same as the Tekelek 425 wall control. The special wall control should only be used to deal with excessive air flow and or noise problem installations.

21 Page 14 Cooler Operation N-E3 Models (cont) Pre-Wetting the Filter Pads Tekelek 425 Wall Control Auto Mode Pre-Wet: If the power to the cooler has been ON, but the pump has been OFF longer than 15 minutes, then the wall control will power the cooler to perform a Pre-Wet. The fan light will flash during this Pre-Wet only. The Tekelek 425 will turn the pump ON for a 2 minute Pre-Wet, then turn it OFF again, and then the fan will commence running at minimum speed. N-E3 Pre-Wet: The N-E3 module has been pre programmed to Pre-Wet the filter pads whenever the pump is turned ON (manual & Auto modes). The Pre-Wet time depends on how long the pump has been turned OFF, allowing the pads to dry. If the pump has been OFF for less than 2 minutes (ShortDryPadTime), then no Pre-Wet will occur. If the pump has been OFF for less than 10 minutes (LongDryPadTime), but longer than 2 minutes (ShortDryPadTime), a 1 minute (ShortPrewetTime) will apply. If the pump has been OFF for longer than 10 minutes (LongDryPadTime) then a 2 minute (LongPrewetTime) will occur. If the power supply to the N-E3 has been interrupted, the first Pre-Wet will be 2 minutes (LongPrewetTime).

22 Cooler Operation N-E3 Models (cont) Tekelek 425 Auto Mode Operation Sequence If the Tekelek 425 wall control is turned ON in auto mode, in readiness to start the cooler as the temperature increases, then the following cooler starting sequences will occur. When the room temperature is lower than 1 0 C. below the set point, then neither the pump or the fan will operate. Page 15 If the pump and fan have both been OFF for longer than 15 minutes, when the room temperature reaches 1 0 C. below the set point, the Tekelek 425 will turn the pump ON for a 2 minute Pre-Wet, then turn the pump OFF again, then the fan will commence running at minimum speed. If the room temperature decreases with the operation of the cooler, then the fan will turn OFF again. When the room temperature is at C. below the set point the pump will turn ON again. This signal for the pump to turn ON may force the N-E3 to perform a Pre-Wet, depending on the time the pump has been OFF, and forces the fan to stop again for that period. i.e. 1 or 2 minutes When the room temperature is at C. above the set point, the fan speed will increase slowly, and will be at maximum speed at 4 0 C. above the set point. If when the wall control is turned ON, the room temperature is higher than the set point, then the fan and pump are initiated together and a Pre-Wet will occur, according to the time the pump has been OFF as described above.

23 PUMP OFF ON Comfort Level SET POINT o o o o o o o FAN OFF ON (min) FAN INCREASE SPEED FAN (max)

24 Page 16 Cooler Operation N-E3 Models (cont) Pump Flush From the start of any pump operation, the pump will be timed to turn OFF for 15 seconds at 15 minute intervals, to allow the water head in the feed tube to the distribution spreader to back flush the pump, and keep it clear of blockages. This pump operation interruption does not affect any other Cooler functions. Networker Service Parameters for N-E3 The table below shows the default values for the N-E3 module. The 2 changes are highlighted: The flush cycle count has increased to 20. The long Pre-Wet time has been reduced to 120 seconds (2 minutes). Name No. Range Units Defaul t Description ServoCloseDelay Minutes 60 Delay after pump and fan turn OFF, before ServoSeal closes FillTime Minutes 15 Maximum time for an empty tank to fill to a water sensor level MinSpeed 3 * RPM * Minimum fan speed. MaxSpeed 4 * RPM * Maximum fan speed. ModelNum Units 1 Model type number Short DryPadTime Minutes 2 Time pump can remain OFF before a pre-wet is required. FlushService Cycles 20 Number of tank refills before a FlushService ShortPrewetTime seconds 60 Normal (short) Pre-Wet time 18 LongPrewetTime seconds 120 Long Pre-Wet time

25 LongDryPadTime Minutes 10 Time pump is OFF to force long pre-wet *Defaults to RPM specified by model number selection

26 Page 17 N-E3 Water Management System FlushService Guide Table The higher the quality of the water supply to the cooler, the more tank refills Cooler can operate before a FlushService will be required. As the water quality also varies the Wet Test voltage readings, the appropriate FlushService cycle may be individually set to that water quality. The following table is a guide to the FlushService cycle rates based on the entering water supply quality. Before checking the voltage reading on the Trident probes, ensure that the Cooler tank, pads, and all 3 stainless steel probes are clean. The voltage reading should be based on the initial fill (fresh clean water) of the tank, when using this guide. The voltage may vary between the Low and High Level Water Sensors, so average the 2 voltage readings. Any change from the default flush count setting should be recorded on both the Coolers parameter change sticker and the service call sheet. Trident Voltage FlushServic e Cycle Rate 0 <--> 2 Volt 2 <--> 3 Volt 3 <--> 6 Volt 6 <--> 8 Volt 10 Cycles 15 Cycles 25 Cycles 35 Cycles

27 Cooler Operation BC-E1 Models General Operation First Fill Operation When the Cooler's pump is turned ON, the BC-E1 will treat this as starting the operation for the first time. Page 18 Because these models do not have a dry tank operation (no Dump), but do use the Trident Water Management, it is not known if there is any or how much water is in the tank from previous use. If both the High and Low Level Water sensors detect the water, then the tank is assumed to be full, and the pump can start immediately. When water is detected at the Low Level Water sensor, but not at the High Level Water sensor, the tank is filled to the High Level Water sensor before the pump is turned ON. If both the High and Low Level Water sensors do not detect water when the pump is required to operate, then the Water Inlet Solenoid is turned ON until the water level is detected at the High Level Water sensor (must be within 15 minutes), and the pump is turned ON when the water has reached the Low Level Water sensor. If the water is not detected on either sensor within the 15 minute filling time, then the BC-E1 will lockout the Pump and Water Inlet Solenoid, but allow the fan to continue function. The first fill operation is completed when the Water Inlet Solenoid turns OFF following one of the above filling sequences. Tank Refilling Operation During normal operation with both the fan and pump turned ON, water is evaporated from the tank. When the water signal circuit is lost at the Low Level Water sensor, the Water Inlet Solenoid is opened to fill again to the High Level Water sensor (must fill again within 3 minutes).

28 Page 19 Cooler Operation BC-E1 Models (cont) General Operation (cont) If the Cooler pump has been OFF longer than 2 minutes the Cooler is programmed to automatically Pre-Wet the filter pads when the pump is turned ON, before the fan can start operating. This is to ensure in all circumstances the filter pads reach full saturation, and optimum cooling potential when the fan starts. The automatic Pre-Wetting time of the dried filter pads, will depend on how long the Cooler's pump has been OFF, as follows: If the pump has been OFF for less than 2 minutes (ShortDryPadTime), then no Pre-Wet will occur. If the pump has been OFF for less than 10 minutes (LongDryPadTime), but longer than 2 minutes (ShortDryPadTime), a 1 minute (ShortPrewetTime) will apply. If the pump has been OFF for longer than 10 minutes (LongDryPadTime) then a 2 minute (LongPrewetTime) will occur. If the power supply to the BC-E1 has been interrupted, the first Pre-Wet will be 2 minutes (LongPrewetTime). From the start of any pump operation, the pump will be timed to turn OFF for 15 seconds at 15 minute intervals, to allow the water head in the feed tube to the distribution spreader to back flush the pump, and keep it clear of blockages. This pump operation interruption does not affect any other Cooler functions.

29 Cooler Operation BC-E1 Models (cont) Flush Service Operation The BC-E1 module program performs a tank flush at regular intervals, to dilute any salt and sediment build up as the unit is operating. The flush service will not affect the normal pump, or fan functions of the Cooler. Page 20 The BC-E1 module has a bridge link adjacent to the wall control loom plug terminal. This link determines when the tank flush is performed by the number of times the tank has been refilled. Bridge Link ON = 20 refills before a Flush Service. Bridge Link OFF = 10 refills before a Flush Service. Refer to diagram on page 22 for details. These refills are the number of times the water has filled to the High Water Level Sensor, and then evaporated down to the Low Water Level Sensor. Each sequence of set refills of the tank, will force a flush service operation, although the time between each Flush Service can vary, according to the conditions and Cooler setting. When the water level evaporates down to the Low Water Level Sensor for the set tank re fill for the Flush Service, the water inlet solenoid will open and fill the tank to the high water level, then remain open for a further 100 second period. The action of the fresh water entering, mixing and overflowing out from the tank, dilutes the salt and sediment ratio back to the original supply water condition.

30 Page 21 Cooler Operation BC-E1 Models (cont) Fan Operation DC Brake The BC-E1 will apply a brake to stop the rotation by energising the motor with DC Voltage to ensure the fan motor will not be energised and driven in the reverse direction. DC power will only be applied to the motor, if at the time the fan motor is powered, the motor has not been previously powered for a least 10 seconds. The DC brake will then remain ON for 5 seconds, before the power to start the fan motor is applied. Initial Start The fan motor will initially be powered with the maximum voltage for a 2 second hard start period to ensure the motor will turn even at low fan speed settings. The fan motor Start windings are independently powered, with only the motor Run winding phase controlled. The BC-E1 module has a bridge link to select between 2 maximum speed settings, although the actual fan speed will depend on conditions and system duct resistance's, they will approximate the control settings used in the Contour N-E3 module. Bridge Link ON = Model 1. Default for Contour L10, L20, & L30 Bridge Link OFF = Model 2. Default for Contour L40, & L50 Refer to diagram on page 22 for details.

31 Cooler Operation BC-E1 Models (cont) Electronic Control Module Operation Page 22 Model (Fan RPM) Bridge Link Flush Cycle Count Bridge Link Trident Water Management Loom Plug Tekelek 485 Wall Control Loom Plug BC-E1 Module The controller is fitted with an internal 8 Amp fuse to protect the PCB circuitry. The 8 Amp fuse will protect the controller from short circuit and/or high current draw, on the following circuits: Pump Water inlet solenoid Fan motor PCB relays

32 Abnormal Operation Trident Water Management System The BC-E1 module has been programmed to modify the water management handling (LIMP mode), if one of the water sensor probes is malfunctioning either open circuit or shorted closed circuit. Should both water sensor fail simultaneously, then the Cooler will be forced to operate in a Lockout mode. In LIMP mode, all timed function commence either at the opening or closing of the Water Inlet Solenoid, which ever is appropriate. Low Water Level Sensor (failure) Low Water Level Sensor - Fails to sense or is short circuit. Page 23 Fails to sense Open Circuit Water detected at the High Water Level Sensor, but not seen at the Low Water Level Sensor. From start up the Low Water Level Sensor is open circuit (normal), and water is still not detected when the High Water Level Sensor is closed circuit. Short circuit Closed circuit on Low Water Level Sensor, and open circuit on the High Water Level Sensor, 120 minutes the Water Inlet Solenoid closed, and pump operating. (i.e. low evaporation). Low Water Level Sensor Limp Mode Operation Pump starts operation at the High Water Level Sensor Water Inlet Solenoid closes when water is sensed at the High Water Level Sensor. Water Inlet Solenoid is timed OFF for 4 minutes, then refills to High Water Level Sensor again.

33 Abnormal Operation (cont) Trident Water Management System (cont) High Water Level Sensor (failure) High Water Level Sensor - Fails to sense or is short circuit. Fails to sense: Open circuit on High Water Level Sensor after 3 minutes of detecting water on the Low Water Level Sensor (closed). Page 24 Water is detected at the Low Water Level Sensor only, and Water Inlet Solenoid has open for 15 minutes. Short circuit: From start up, with the Low Water Level Sensor open circuit and the High Water Level Sensor closed circuit, which will force the Water Inlet Solenoid ON for 30 seconds, and the Low Water Level Sensor detects. With both High and Low Level Sensors closed circuit, and the Low Water Level Sensor becomes open circuit whilst the High Water Level Sensor remains closed circuit. High Water Level Sensor Limp Mode Operation On First Fill, the Water Inlet Solenoid closes after 3 minutes of the water detected at the Low Water Level Sensor. Water Inlet Solenoid opens when open circuit occurs on Low Water Level Sensor. Water Inlet Solenoid timed to fill for 30 seconds, then closes again.

34 Page 25 Abnormal Operation (cont) Trident Water Management System (cont) First Fill Operation with a LIMP mode When the BC-E1 module has been operating with a water sensor malfunction, then the first fill operation sequence will be as follows depending on the type of sensor failure and the current water levels. Low Level Water Sensor Failure & High Level Water Sensor Closed Circuit: Pump turns ON immediately and Water Inlet Solenoid remains closed - tank is full. Low Level Water Sensor Failure & High Level Water Sensor Open Circuit: Water Inlet Solenoid turns ON to fill to the High Level Water Sensor or for a 30 second fill period, then turns OFF, and the pump is turned ON. If the High Level Water Sensor does not detect the water within the 30 seconds filling period, the High Level Water Sensor is regarded as failed open circuit, and a lockout will result. High Level Water Sensor Failure & Low Level Water Sensor Closed Circuit: Water Inlet Solenoid turns ON for a 30 second fill period, then turns OFF, and the pump is turned ON. High Level Water Sensor Failure & Low Level Water Sensor Open Circuit: Water Inlet Solenoid turns ON for a 30 second fill period, then turns OFF, and the pump is turned ON when water is detected at the Low Level Water Sensor. If the Low Level Water Sensor does not detect the water within the 30 seconds filling period, the Low Level Water Sensor is regarded as failed open circuit, and a lockout will result.

35 Page 26 Abnormal Operation (cont) Trident Water Management System (cont) Lockout Modes These lockout conditions remain until the pump circuit is cycled OFF and then back ON again. Open Circuit Low & High Level Water Sensors: This will lockout the Water Inlet Solenoid and Pump operation, but will allow the fan to operate. (No water detected within 15 minutes of the Water Inlet Solenoid opening) One Sensor Permanently Open & One Sensor Permanently Closed Circuit: This will eventually, after a time period, lockout the Water Inlet Solenoid and Pump operation, but will allow the fan to operate. (Depends on detecting sequence of Sensor failure) Closed Circuit Low & High Level Water Sensors: This condition will keep the Cooler in a HOLD mode, holding the Water Inlet Solenoid OFF, but will allow the fan and pump to operate. (Closed circuit for longer than 120 minutes with pump/fan ON) If one sensor becomes open circuit, BC-E1 automatically resets.

36 Abnormal Operation (cont) Fan Motor Lockout The fan motor Run winding circuit from the BC-E1 is monitored for open circuit during fan ON operation. Should the circuit be open for longer than 10 seconds, the BC-E1 module will lockout the power supply to the fan. Page 27 The motor lockout will also be displayed by the flashing of the power LED located adjacent to the main isolating switch. This lockout condition can be reset by the cycling OFF and back ON the power supply to the BC-E1 module.

Introduction: Technical Information: Motor Circuit Diagram: Installer Commissioning Instructions:...

Introduction: Technical Information: Motor Circuit Diagram: Installer Commissioning Instructions:... 1 Contents Page Introduction:............ 4-5 Technical Information:............ 6-12 Cooler Circuit Diagram:............ 13 Motor Circuit Diagram:............ 14-15 Installer Commissioning Instructions:............

More information

Brivis Service Manual

Brivis Service Manual Brivis Service Manual Evaporative Cooler AD/C 5 Series N-E1 & Tekelek 461 1999 Supplement This manual is to be used in conjunction with the Service Manual 12 - Cooler - AD / CC (series 4 & 5) Service Manual

More information

Brivis Service Manual

Brivis Service Manual Brivis Service Manual EMS (2) Energy M anagem ent Syst em Servicing shall be carried out only by A uthorised Personnel. T his Service Manual must N O T be left with the O wner. Service Manual 19 Heater

More information

Service Manual - Heater - Electronic (TEK 300) Series - No.2 Issue 6 Printed 2/13/ :51:58 AM 1

Service Manual - Heater - Electronic (TEK 300) Series - No.2 Issue 6 Printed 2/13/ :51:58 AM 1 Service Manual - Heater - Electronic (TEK 300) Series - No.2 Issue 6 Printed 2/13/2014 11:51:58 AM 1 Index Page Technical Information Buffalo 3-6 Wombat 7-11 Upflow 12-14 Downflow 15-16 Airflow Chart 17

More information

COOLING Installer s Manual

COOLING Installer s Manual COOLING Installer s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS PRODUCT a company Scope This Brivis Evaporative Cooler shall be installed in accordance with these instructions,

More information

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EXH, EZH) Introduction...4 Remote Thermostat Control...5 Wall Mounted Thermostat Control...11

More information

Service Manual. Brivis StarPro SP4, SP5 & SP6

Service Manual. Brivis StarPro SP4, SP5 & SP6 Service Manual Brivis StarPro SP4, SP5 & SP6 Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons not permitted

More information

Service Manual Brivis BX5

Service Manual Brivis BX5 Service Manual Brivis BX5 Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons not permitted to obtain this information

More information

REMOTE CONTROL FAN SPEED ECONOMY BATTERY LOW. owner s manual

REMOTE CONTROL FAN SPEED ECONOMY BATTERY LOW. owner s manual REMOTE CONTROL AUTO FAN SPEED COOL PM ECONOMY BATTERY LOW owner s manual Hello and congratulations on purchasing a Breezair Ducted Cooler for your home. Breezair coolers have been designed to provide quiet,

More information

Service Manual 3 Heater MPS & AUTO EMS Vol 1 of 2 Approved Issue 10 Printed 13/02/ :52:21 AM 1

Service Manual 3 Heater MPS & AUTO EMS Vol 1 of 2 Approved Issue 10 Printed 13/02/ :52:21 AM 1 Service Manual 3 Heater MPS & AUTO EMS Vol 1 of 2 Approved Issue 10 Printed 13/02/2014 11:52:21 AM 1 Index Pages INTRODUCTION:......... 4-5 THE N-G1/lo INSTALLATION & SET-UP INSTRUCTIONS:......... 6-8

More information

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030 Technical Training Prodigy Undercounter Cubers Models CU1526, CU2026 and CU3030 List of Major Topics Introduction Installation Operation Maintenance Diagnosis Service Prodigy with a Bin 3 models CU1526

More information

DOMESTIC STEAM GENERATOR Installation Instructions

DOMESTIC STEAM GENERATOR Installation Instructions DOMESTIC STEAM GENERATOR Installation Instructions Please read all of the instructions carefully before commencing installation or using the facility. Contents INTRODUCTION Page 2 TECHNICAL SPECIFICATION

More information

OWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

OWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EA, EXH, EZH) Hello and congratulations on purchasing a Breezair Ducted Cooler for your home.

More information

ROTA-SPRAY PROCESSOR MODEL 1210 (ROTARY-JET) INSTRUCTIONS MEGA PART NO: &

ROTA-SPRAY PROCESSOR MODEL 1210 (ROTARY-JET) INSTRUCTIONS MEGA PART NO: & ROTA-SPRAY PROCESSOR MODEL 1210 (ROTARY-JET) INSTRUCTIONS MEGA PART NO: 500-702 & 500-713 PLEASE READ IMPORTANT UNPACKING INSTRUCTIONS 1. Carefully consider where the unit will be located. It should be

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

INSTALLER S MANUAL. Evaporative Air Coolers. Safety Information Installation Commissioning. Models

INSTALLER S MANUAL. Evaporative Air Coolers. Safety Information Installation Commissioning. Models INSTALLER S MANUAL Safety Information Installation Commissioning Models Classic : KC17 KC21 KC27 KC32 Low Profile : KL16 KL22 KL25 KL28 Kaden Installer's Manual TABLE OF CONTENTS Warnings and Important

More information

Brivis Touch Controller. Installer Manual

Brivis Touch Controller. Installer Manual Brivis Touch Controller Installer Manual Brivis Touch Controller Kit Scope Please read these instructions carefully before installing this product. This manual covers the installation of the wall mounted

More information

INSTALLATION MANUAL TBA Evaporative Cooler

INSTALLATION MANUAL TBA Evaporative Cooler INSTALLATION MANUAL TBA Evaporative Cooler (English) (TBA) INDEX CABLE LENGTHS, STANDARD WALL CONTROL........................................ 2 COOLER COMPONENTS.............................................................

More information

Service Manual 4 Heater MPS & AUTO EMS Vol. 2 of 2 Approved Issue 10 Printed 13-Feb-14 11:52:53 AM 1

Service Manual 4 Heater MPS & AUTO EMS Vol. 2 of 2 Approved Issue 10 Printed 13-Feb-14 11:52:53 AM 1 Service Manual 4 Heater MPS & AUTO EMS Vol. 2 of 2 Approved Issue 10 Printed 13-Feb-14 11:52:53 AM 1 Index BULLETINS & SERVICING INSTRUCTIONS......... 4-19 MPS - Fit AFRO and New Style Burner.........

More information

Auto Drain Installation Instructions.

Auto Drain Installation Instructions. Kit No 077444 Auto Drain Installation Instructions. TO SUIT RPC- RPA - RPB - AL COOLERS 1 2 8 9 3 9 6 4 7 5 1 2 3 4 5 114101 Drain valve. 638614 Pcb. (Inside control box.) 833811 Probe. 638843 Brkt Large.

More information

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM) OWNER S MANUAL Evaporative Cooler (English) (LCB, CPL, CPS, BM) Original English Instructions TABLE OF CONTENTS INTRODUCTION 4 WALL CONTROL FUNCTIONS 5 STARTING YOUR COOLER 5 AUTOMATIC MODE 6 MANUAL MODE

More information

CAUTION. No-Load Performance, Controls in Normal Position

CAUTION. No-Load Performance, Controls in Normal Position Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY F SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform

More information

Auto Drain Installation Instructions.

Auto Drain Installation Instructions. Kit No 077444 Auto Drain Installation Instructions. TO SUIT RPC- RPA - RPB 2 SPEED ONLY 2 8 9 3 9 6 4 7 5 2 3 4 5 40 Drain valve. 63864 Pcb. (Inside control box.) 8338 Probe. 638843 Brkt Large. RPB 200-800

More information

Brivis Service Manual CC3 Gas Ducted Heater Compact Classic

Brivis Service Manual CC3 Gas Ducted Heater Compact Classic Brivis Service Manual CC3 Gas Ducted Heater Compact Classic Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons

More information

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility

More information

APP Environmental Services P/L.

APP Environmental Services P/L. APP Environmental Services P/L. 20 LITTLE BOUNDARY ROAD LAVERTON NORTH. VIC. 3026. PO BOX 519, ALTONA NORTH. VIC. 3025. PHONE: 03 9362 4614 FAX: (03) 9362 4603 Mobile: 0418 547653 Email: david@appenviro.com.au

More information

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2. UNDERCOUNTER SERVICE MANUAL Ecoboiler UC4L 2.4kW 1000740 Ecoboiler UC10L 2.8kW 1000741 Ecoboiler UC10L 5.6kW 1000742 Ecosmart UC4L 2.4kW 1000750 Ecosmart UC10L 2.8kW 1000751 Ecosmart UC10L 5.6kW 1000752

More information

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications EnviroMagic Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications World leading climate control solutions Seeley International is Australia s largest air conditioning

More information

Peacock Salt. Multisol Pro VA Operation & Training Manual

Peacock Salt. Multisol Pro VA Operation & Training Manual Multisol Pro VA Operation & Training Manual Peacock Salt CONTENTS PAGE 1. Saturator Tank Diagram 2 2. Saturator Cabinet Diagram 3 3. Saturator Function 4 4. Inlet water 5. Adding Salt 6. Producing Brine

More information

MIX Boiler & Font Range Service Manual

MIX Boiler & Font Range Service Manual MIX Boiler & Font Range Service Manual 1000870# 1000871# 1000875# 1000880# 1000887# 1000878 1000879 2300268 www.marcobeveragesystems.com Ireland Tel: +353 (1) 295 2674 UK Tel: +44 (0207) 2744577 Service

More information

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator. Bottom Mount Refrigerator Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTION

More information

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A

INSTALLATION MANUAL. TBA Evaporative Cooler. (English) (TBA) ILL1456-A INSTALLATION MANUAL TBA Evaporative Cooler ILL1456-A (English) (TBA) TIMER AUTO COOL ILL1128-A ILL239-D TIMER AUTO COOL ILL1128-A ILL972-A Step 1 Step 2 Step 3 Step 4 SAFETY FIRST! 1. Read & understand

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

LEAKSTOPPER 1 Single zone water leak detection system

LEAKSTOPPER 1 Single zone water leak detection system LEAKSTOPPER 1 Single zone water leak detection system WHAT DOES THE PRODUCT DO? The LeakStopper 1 detects the presence of water in environments where it is not supposed to be. Should water be detected

More information

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN) Ovens Service Manual Models OMFP6010 CONTENTS This document has been published to be used for service only. The contents

More information

I/O ZONE 560/583 AND OPERATION MANUAL

I/O ZONE 560/583 AND OPERATION MANUAL UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in

More information

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER RANGE Multizone water leak detection systems LEAKSTOPPER RANGE Multizone water leak detection systems WHAT DOES THE PRODUCT DO? The LeakStopper detects water leaks and instantly triggers an alarm to warn you. It is capable of monitoring between 2

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( ) SERVICE MANUAL Ecoboiler Model range: T20 (1000662) T30 (1000663) Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland Tel: (01) 295 2674 Ireland

More information

EUQA Humidifier, for circulated water

EUQA Humidifier, for circulated water Sizes 0 4, 50, 5 Sizes 44, 5 84 6 5 4 6 5 4 5 6 8 7 9 7 8 0. Control box, on the outside. Control box, on the inside. Shut-off valve (not included) 4. Water filter, max. 500 mm mesh (not included) 5. EUAZ-08

More information

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY

More information

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ecoboiler T20 & T30 SERVICE MANUAL Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland Tel: (01) 295 2674 Ireland Fax: (01) 295 3715 UK Tel:

More information

Ecoboiler SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Ecoboiler SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ecoboiler SERVICE MANUAL Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland Tel: (01) 295 2674 Ireland Fax: (01) 295 3715 UK Tel: (0207) 274

More information

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English) OWNER S MANUAL EXQ / EZQ / EXS Evaporative Coolers (English) Original English Instructions Hello and congratulations on purchasing a Breezair evaporative cooler for your home. At Seeley International

More information

Bottom Mount Refrigerator Technical Information

Bottom Mount Refrigerator Technical Information Bottom Mount Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTIN All safety information

More information

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL The LeakStopper Multizone detects the presence of water in environments where it is not supposed to be. Should water

More information

Mix Boiler & Font Range ( #, #, #, , )

Mix Boiler & Font Range ( #, #, #, , ) Mix Boiler & Font Range (1000870#, 1000871#, 1000880#, 1000878, 1000879) Service Manual Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland

More information

LQQA Humidifier, for circulated water

LQQA Humidifier, for circulated water Size -84 5 Fig. 4 5 4 6 8 7 9 7 8. Control box, on the outside. Control box, on the inside. Shut-off valve (not included) 4. Water filter, max. 5 mm mesh (not included) 5. LQAZ-8 Water trap (accessory)

More information

B R I V I S I C E B E R G C O O L I N G

B R I V I S I C E B E R G C O O L I N G B R I V I S I C E B E R G C O O L I N G I n s t a l l e r s M a n u a l PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND USING THIS PRODUCT Scope This manual covers the installation and setup

More information

LQQA Humidifier, for circulated water

LQQA Humidifier, for circulated water Size 5 Fig. 6 5 6 8 7 9 7 8. Control box, on the outside. Control box, on the inside. Shut-off valve (not included). Water filter, max. 5 mm mesh (not included) 5. LQAZ-8 Water trap (accessory) 6. Water

More information

Wall Controller & Thermostat

Wall Controller & Thermostat Wall Controller & Thermostat Thank you for purchasing a Genuine component from Seeley International. This Wall Controller has been engineered and manufactured to the highest standard to maximise the performance

More information

TYPE TR Duct Ducting type

TYPE TR Duct Ducting type SUPPLEMENTARY INSTRUCTION BOOKLET GB140c AIR HEATER TYPE TR Duct Ducting type YOU MUST READ THIS DOCUMENT BEFORE COMMENCING INSTALLATION. THE USER MUST BE INSTRUCTED IN USING THE APPLIANCE. KEEP THIS DOCUMENT

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL REMOTE FLOOD AM PM PHOTO F rh PPM TEMPERATURE HUMIDITY SELECT RUN LAMP START FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP

More information

DIGIHEAT IN LINE HEATERS

DIGIHEAT IN LINE HEATERS DIGIHEAT IN LINE HEATERS Installation and operation manual for Single & Three Phase Models Offices - Australia NSW - Sydney (Head Office) Tel: +61 2 9898 8600 QLD - Brisbane Tel: +61 7 3299 9900 VIC/TAS

More information

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 MODEL UC 60e INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 www.cmadishmachines.com TABLE

More information

Please do not hesitate to contact us with any enquiries.

Please do not hesitate to contact us with any enquiries. PRIMARILY DESIGNED TO BE FITTED INTO ANY CARAVAN WITH AN ONBOARD WATER PUMP SUCH AS THE WHALE, SHURFLO OR FIAMMA PUMPS, WHICH MOST CARAVAN MANUFACTURERS FIT AS STANDARD. IDEAL FOR WINTER CARAVANING. THE

More information

GEYSERWISE INSTRUCTION MANUAL

GEYSERWISE INSTRUCTION MANUAL GEYSERWISE INSTRUCTION MANUAL GEYSERWISE MAX DELTA T ALL IN ONE HOT WATER MANAGEMENT Before operating and installation, carefully read all instructions. Do not discard this manual. INDEX 1. Package Contents

More information

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector) SMAC Controller Industrial Lubrication Systems Operation The SMAC Controller is a multi-purpose programmable controller used with industrial lubrication systems. Controller settings are saved whenever

More information

Brivis Service Manual BX3 Buffalo Gas Ducted Heater

Brivis Service Manual BX3 Buffalo Gas Ducted Heater Brivis Service Manual BX3 Buffalo Gas Ducted Heater Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons not permitted

More information

Prodigy Flaked and Nugget Ice Machines Technical Review

Prodigy Flaked and Nugget Ice Machines Technical Review CM 3 Control System Update Prodigy Flaked and Nugget Ice Machines Technical Review Evaporator Assembly Behind Ice Chute Assembly Fan Blade Control Panel Water Reservoir Air Filter Compressor Ice Chute

More information

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL Technicold Marine Systems www.technicold.com Technicold by Northern Lights 1419 W. Newport Center Drive Deerfield Beach, FL 33442 Tel:

More information

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products 7 71 Flame Safeguards LAE LFE Flame safeguards for burners with intermittent operation The LAE is used for the supervision and indication of oil flames The LFE is used for the supervision and indication

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added

More information

LAE10 LFE10. Use. Series 02

LAE10 LFE10. Use. Series 02 ISO 00 Flame Safeguards 7 7 LAE L Series 02 Supplementary data sheets 772 and 773 Flame safeguards for burners with intermittent operation. For safety reasons - self-test of flame supervision circuit,

More information

GKv 5710 / 5760 GKv 6410 / 6460

GKv 5710 / 5760 GKv 6410 / 6460 After Sales Service International Service Manual No. 21/2007 (version 01) Service Information LWL/KDT/baj/14.05.07 Appliance Documentation GKv 5710 / 5760 GKv 6410 / 6460 Refrigerator for the catering

More information

Humidifiers Dealer Parts List Model 400/400M Humidifiers

Humidifiers Dealer Parts List Model 400/400M Humidifiers Effective Date: September 1, 2012 Humidifiers Dealer Parts List Model 400/400M Humidifiers MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base (blue/gray) 1 4734 4734

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY FOR SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Remove Or Destroy DANGER Electrical Shock Hazard Only authorized technicians should perform

More information

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION Bottom Mount Refrigerator Technical Information AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0! CAUTION Due to a possibility of personal injury or property damage, always contact an authorized technician

More information

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Bottom Mount Refrigerator Technical Information JBC2088HT* JBC2088HT*1, JBL2088HES JBL2088HES1, JBR2088HES JBR2088HES1, JFC2089HE* JFC2089HE*1, JFC2089HP* JFC2089HP*1, JFC2089HT* JFC2089HT*1, KBFA20ERBL

More information

PRODUCT GUIDE. Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ Phone Fax Web Seeleyinternational.

PRODUCT GUIDE. Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ Phone Fax Web Seeleyinternational. PRODUCT GUIDE 2017 Seeley International Americas 1002 S 56 Ave Suite 101 Phoenix AZ 85043 Phone 602 353 8066 Fax 602 353 8070 Web Seeleyinternational.com Seeley International has a policy of continuous

More information

Service Manual Zip HydroTap Miniboil Boiling and ambient drinking water for kitchens and the home.

Service Manual Zip HydroTap Miniboil Boiling and ambient drinking water for kitchens and the home. Service Manual Zip HydroTap Miniboil Boiling and ambient drinking water for kitchens and the home. Zip HydroTap Miniboil - Service Manual - 800557 - September 2012 v1.02 Page 1 of 28 Contents General information

More information

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC WIRING DIAGRAMS R410A MODELS 2OAC/2OACH PAC CAC PWC OWC WIRING 02172017 TABLE OF CONTENTS PAGE 2OACH Deluxe Portable Air-cooled Heat Pump Electronic Controller... 2-3 Piping Schematic... 4 Single Phase

More information

BX444-Mc Gas Detector

BX444-Mc Gas Detector Installation and User Guide Rev.01. BX444-Mc Gas Detector Application Duomo is recognised within the gas industry for providing a comprehensive range of low cost, high reliability gas detection for many

More information

Humidifiers Dealer Parts List

Humidifiers Dealer Parts List Effective Date: July, 204 Revised Date: March 20, 205 Humidifiers Dealer Parts List Model 400/400M Humidifiers 6A 6B MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base

More information

Service Documentation

Service Documentation After Sales Service International Service Manual No. 16/2010 Service Documentation LWL/KDT-baj/30.06.10 Appliance Documentation GKv 4310 / 4360 from Index 20 Commercial refrigerator, ventilated GKv 5730

More information

INSTALLATIONN GUIDE & OPERATION MANUAL

INSTALLATIONN GUIDE & OPERATION MANUAL INSTALLATION INSTRUCTIONS ECO # 1569 REVISION #0006 FCS SERIES MODEL 5025, 5045,7525 & 7545 INSTALLATION INSTRUCTIONS BY: DATE: 01/23/2013 INSTALLATIONN GUIDE & OPERATION MANUAL MOTOR OPERATOR (V3.02 Controls)

More information

OPERATING and SERVICE GUIDE USA - Coin in / Ticket out Feature.

OPERATING and SERVICE GUIDE USA - Coin in / Ticket out Feature. OPERATING and SERVICE GUIDE USA - Coin in / Ticket out Feature. Produced by ; Harry Levy Amusement Contractor Ltd Unit 6 Patricia Way Pysons Road Industrial Estate Broadstairs Kent CT10 2LF Tel 01843 866

More information

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems. ECONOPLATE H1-heat only HEAT INTERFACE UNIT Installation, Commissioning and Servicing Instructions for unvented systems. Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

Scotsman Technical Training. CU50 Cube Ice Machine

Scotsman Technical Training. CU50 Cube Ice Machine Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor INSTALLATION INSTRUCTIONS AND OPERATION MANUAL AlarmGard Fire Door Operator FT-5EPB / FT-50EPB Single Motor IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of death or serious injury to

More information

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS Ecoboiler UC4L 2.4kW (1000740#) Ecoboiler UC10L 2.8kW (1000741#) Ecoboiler UC10L 5.6kW (1000742#) Ecoboiler UC4L 1.5kW 110V (1000747) Ecosmart UC4L 2.4kW

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1-316-832-4357

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS Note: This manual may also be used for 6536-871 series heat pumps if the 6535-3209 Replacement

More information

Dough Retarder Prover. Service Manual

Dough Retarder Prover. Service Manual Service Manual Revision 3 June 2000 Dough Retarder Prover - Service Manual RBC MKII Controller Revision 6 Page 2 CONTENTS Page(s) 1. INTRODUCTION 3 2. RBC MK 2 CONTROLLER OPERATION 5-9 Process Cycle Overview

More information

Trouble Shooting and Help Guide TT / TTB 1840

Trouble Shooting and Help Guide TT / TTB 1840 FloorCare Trouble Shooting and Help Guide TT / TTB 1840 Make sure you read and fully understand your 1840 manual before using the machine. The 1840 has been designed to scrub and dry a variety of hard

More information

FEC400 Series. Installation Manual

FEC400 Series. Installation Manual FEC400 Series Conventional microprocessor controlled fire detection and alarm panels with extinguishing control Installation Manual Version 2.3 / August 2004 Aritech is a GE Interlogix brand. http://www.geindustrial.com/ge-interlogix/emea

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation

More information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit PRODUCT INSTRUCTIONS Fire Door Control Panel (FDCP) Floats Rd, Wythenshawe, Manchester. M23 9WB T: 44 (0)161 945 4561 F: 44 (0)161 945 4566 Stock Code Description Doc No: PI115 00133 00134 Ellard Fire

More information

Gas Tumble dryer BG 44A_

Gas Tumble dryer BG 44A_ Gas Tumble dryer BG 44A_ 2 ON/OFF 3 4 Note that gas is not lit when the drum is turning Anti-clockwise. 5 SERVICE INSTRUCTIONS PROGRAMME Clockwise rotation of the control knob closes switch contacts within

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

AQUARIUS 45 MARINE SERVICE MANUAL

AQUARIUS 45 MARINE SERVICE MANUAL AQUARIUS 45 MARINE SERVICE MANUAL CONTENTS: PAGE 1. INTRODUCTION 3 2. SAFETY INSTRUCTIONS 4 3. BASIC INSTRUCTIONS 5 3.1. Installation Details 5 3.2. Operating the Boiler for the First Time 6 3.3. Troubleshooting

More information