Service Manual Brivis BX5

Size: px
Start display at page:

Download "Service Manual Brivis BX5"

Transcription

1 Service Manual Brivis BX5 Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons not permitted to obtain this information by Brivis Climate Systems. 279 Issue 1 - Service Manual Heater BX5 March 2015

2 Issue Date Description 1 Feb 14 Introduction of the 5 star buffalo replacement. 279 Issue 1 - Service Manual Heater BX5 March 2015 ii

3 SCOPE This Service Manual contains information relevant to servicing a Brivis Buffalo BX5 heater. It is intended for Service personnel who have received adequate training on Brivis Gas Fired Ducted Central Heaters, in particular Brivis StarPro series heaters. The main sections covered include: Heater operation Technical Specifications Installation & Commissioning Troubleshooting Servicing Component Removal/Assembly Procedures Trouble Shooting Flow chart Further information on installation and operation of Brivis Buffalo BX5 Series heaters can be obtained from the Brivis Heater Installer s Manual. Note: DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. DO NOT MODIFY THIS APPLIANCE. 279 Issue 1 - Service Manual Heater BX5 March 2015 iii

4 Table of Contents 1.0 HEATER OPERATION Operation Overview Technical Information BX520EN Technical Information BX526EN Wiring Diagrams Motor Wiring Diagrams NG-2A Control Operation Installer Menu Service Menu COMPONENT OPERATION Gas Valve Burner Spark Igniter Flame Sensor Combustion Fan Combustion Fan Speed Reduction Pressure Switch Main Fan Assembly Heater Start-up Flow Chart Heater Shut down Flow Chart INSTALLATION & COMMISSIONING TROUBLESHOOTING Fault Code Summary ERROR 30 FAN_LIMP ERROR 32 DATA_Err ERROR 33 MDGV_LIMP ERROR 35 No_SA-THM ERROR 36 BadSA-THM ERROR 40 OHEAT_R-A ERROR 41 OHEAT_S-A ERROR 42 OHEAT_THM ERROR 43 OHCooLDwn ERROR 44 RoLLOut ERROR 45 LOW24VOLT ERROR 46 IGR_NOFLM ERROR 47 IGR_BDFLM ERROR 48 LOST_PRES ERROR 49 LOST_FLME ERROR 51 RLT_NOGAS ERROR 52 FLM_NOGAS ERROR 53 OH_LKOUT ERROR 54 RoL_LKOUT ERROR 55 IGINVALID ERROR 56 PRES_STOF ERROR 57 PRES_STON ERROR 58 PRES_FAIL ERROR 60 MOTOR_O-C ERROR 61 PVCR-STOF ERROR 62 PVCR_STON ERROR 63 PVCR-FAIL Error 64 GAS_LKOUT Issue 1 - Service Manual Heater BX5 March 2015 iv

5 4.32 ERROR 65 MTR_LKOUT ERROR 66 SVCR_STOF ERROR 67 SVCR_STON ERROR 68 SVCR_FAIL ERROR 69 FUSE_BLOW ERROR 70 SS-SDNERR ERROR 71 SS-STAERR MAIN COMPONENTS SERVICING Gas Valve Servicing Gas Valve Checking and Adjustment (only if required) Combustion Fan Servicing Spark Igniter Servicing Flame Sensor Servicing Pressure Switch Servicing Main Fan Assembly Servicing Unit operation Transformer Voltages and resistance Components on the BX5 Series REMOVAL PROCEDURES Burner Assembly Removal Gas Manifold Assembly Removal Gas Valve Removal Pressure Switch Assembly Removal Combustion Fan Removal NG-2A Electronic Control Board Removal Heat Exchanger Removal Ballast resistor and loom Removal Flue Pipe Removal Main Fan Assembly Removal Brivis Acc Network 516 Module Low - Voltage NET 516 Control Board Settings FLUEING REQUIREMENTS Issue 1 - Service Manual Heater BX5 March 2015 v

6 1.0 HEATER OPERATION This section provides an overview of the operation of the Brivis BX series heaters. It is vital that an understanding of how Brivis BX heaters, and their components, operate in order to service the Brivis BX Series heater effectively and efficiently. BX5 Unit Typical Components Spark Igniter Flame roll out bar Gas valve Combustion fan motor Combustion fan relay Burner Manifold Combustion fan ballast resistor NG2 Board and cover Pressure switches 279 Issue 1 - Service Manual Heater BX5 March 2015

7 1.1 Operation Overview The Brivis BX series heater is a 5 Star unit natural gas. The BX series heater is an induced draught combustion system, consisting of direct spark ignition with electronic gas modulation to vary the heat output to the desired level. The supply air temperature (air leaving the heater) is monitored via a thermistor located in the duct near the heater outlet, and is continuously monitored by the heater control board. The desired temperature can be set within a suitable range during commissioning; the factory setting is 45 C. Note. For Add-On Refrigeration system the thermistor shall be installed in the supply air (discharge) pop of the indoor coil only. The combustion fan is responsible for removing the combustion products from the heat exchanger. When the supply air thermistor reaches its desired temperature the control board will start to modulate the gas valve by reducing the Milliamps to the modulation coil. The two speed flue fan control is enabled when the gas valve modulation coil modulates to 90mA. The onboard Add-On Refrigeration 24volt relay will the send power to the internal mains relay which would send mains voltage through the power resistor. The voltage from power resistor which is in series with the combustion fan motor coil will thereby reducing the effective voltage across the fan. This will reduce the RPM of the combustion fan which is then run at a lower speed. During ignition, the gas rate is between an intermediate level and full gas rate, and maintains this rate during the flame confirmation period. After flame confirmation, the gas rate rises to the maximum allowable level, known as the nominal gas consumption (NGC). Once the heater approaches the set supply air temperature, the control modulates the gas rate to maintain the set supply air temperature. As the gas rate modulates to its desired rate the two speed flue fan control is enabled by switching a power resistor in series with the fan motor coil thereby reducing the effective voltage across the combustion fan. This power resistor is switched in using an internal mains rated relay via the onboard add-on refrigeration relay according to the current level sensed through the modulating coil of the gas valve. The airflow rate is controlled via speed monitoring of the main fan. The room fan can be controlled to any necessary speed. During warm up and cool down, the room fan ramps up and down in speed respectively. During steady state operation the room fan speed runs at the set speed, which is set during commissioning. Feedback is gained via a tachometer known as the speed sensor located on the main fan motor. When adaptive zoning is part of the system and zones are opened or closed by the user, the fan speed adjusts to suit the required airflow rate. Both BX520 and BX526 models have an aluminised steel tube & plate primary heat exchanger. To ensure for adequate air for combustion, a vacuum pressure switch measures the vacuum pressure prior to the combustion fan. The second pressure switch ensures that when the second speed combustion fan is engaged then the 50 pascal pressure switch will allow the unit to keep running freely. The following provides an overview of the Brivis BX5 heater s NG-2A control and main components and how they function. 279 Issue 1 - Service Manual Heater BX5 March

8 1.11 Technical Information BX520EN AGA Approval No.7985 Energy Label Star Rating: 5.1 Dimensions Length Width Height Weight Cabinet 850mm 420mm 775mm 57Kg Gas Type Input (max) Output (max) Burner Pressure Maximum Minimum Modulation Injector Main Burner Natural Gas 80Mj 20Kw Natural Gas 650Pa 150Pa 2.25mm Fan Motor Standard Combustion Fan Model FASCO FIME Model No BNVA-A20 GR04100 Watts 315watts 60watts Amps 4.2 n/a Capacitor 15uF Fan Impellor Size 240mm x 180mm (9 x7 ) Pressure Switch Top Tank Nominal 115Pa ±12 Cleveland NS Pressure Switch Top Tank Nominal 50Pa ±12 Cleveland NS Return Air Grille Size With Filter 0.39 m 2 No Filter 0.26m 2 Airflow Total Static Pressure 50 Pa 75 Pa 100 Pa 125 Pa Standard XA Base Box Gas Valves: Honeywell VK8105m/SIT 845 Sigma Speed Sensor: Tek 507 Primary Heat Exchanger: Aluminium Steel Tubes Control Fuse: 2 Amp type 3AG Main Fuse: 250Vac 8Amp Slow Blow Transformer: 220Vac 2.25Amp Over Temperature Switch: Supply Air 110 c ± 3.5 c Ballast Resistor 600 Ohms Electronic Heater Controller: FEATURES: NG-2A Control Board Liquid Crystal Display screen to show unit operation status. Installer system set-up function buttons. 2 Amps fuse (circuit protection). 8 Amp main fuse. 24 Volt AC output terminal. Thermistor input (Supply Air Terminal). Connection for analog wall control. Connection for Networker NC-6. 2 x 24v relay for zoning connection. Power supply input terminals. Main fan power supply output terminals. Combustion fan power supply output terminals. Speed sensor (fan motor) input terminal. NG-2A power supply output terminal. Pressure switch sensor top tank. 2 Speed combustion fan via a power resistor. 279 Issue 1 - Service Manual Heater BX5 March

9 1.12 Technical Information BX526EN AGA Approval No Energy Label Star Rating: Dimensions Length Width Height Weight Cabinet 1030mm 579mm 894mm 67Kg Gas Type Input (max) Output (max) Burner Pressure Maximum Minimum Modulation Injector Main Burner Natural Gas 120Mj 30Kw Natural Gas 715Pa 150Pa 2.25mm Fan Motor Standard Combustion Fan Model FASCO FIME Model No BNVA-A20 GR04100 Watts 315watts 60watts Amps 4.2 n/a Capacitor 15uF Fan Impellor Size 240mm x 180mm (9 x7 ) Pressure Switch Top Tank Nominal 115Pa ±12 Cleveland NS Pressure Switch Top Tank Nominal 50Pa ±12 Cleveland NS Return Air Grille Size With Filter 0.54 m 2 No Filter 0.36m 2 Airflow Total Static Pressure 50 Pa 75 Pa 100 Pa 125 Pa Standard XA Gas Valves: Honeywell VK8105m/SIT 845 Sigma Speed Sensor: Tek 507 Primary Heat Exchanger: Aluminium Steel Tubes Control Fuse: 2 Amp type 3AG Main Fuse: 250Vac 8Amp Slow Blow Transformer: 220Vac 2.25Amp Over Temperature Switch: Supply Air 110 c ± 3.5 c Ballast Resistor 440 Ohms Electronic Heater Controller: FEATURES: NG-2A Control Board Liquid Crystal Display screen to show unit operation status. Installer system set-up function buttons. 2 Amps fuse (circuit protection). 8 Amp main fuse. 24 Volt AC output terminal. Thermistor input (Supply Air Terminal). Connection for analog wall control. Connection for Networker NC-6. 2 x 24v relay for zoning connection. Power supply input terminals. Main fan power supply output terminals. Combustion fan power supply output terminals. Speed sensor (fan motor) input terminal. NG-2 power supply output terminal. 2 Pressure switches sensor top tank. 2 Speed combustion fan via a power resistor. 279 Issue 1 - Service Manual Heater BX5 March

10 1.4 Wiring Diagrams 279 Issue 1 - Service Manual Heater BX5 March

11 1.5 Motor Wiring Diagrams Model Fasco 315W BNVA-A20 Fasco 650W BPVA-A12 Power 315 W 650 W Maximum Current 4.2 A 4.3 A Main Fan Motor Capacitor 15±1.5 µf 25±2.5 µf Start Winding 20 C Main Winding 20 C Ω Ω Ω Ω Impellor Size - diam. x width 225 x 180 mm 284 x 265 mm 279 Issue 1 - Service Manual Heater BX5 March

12 1.6 NG-2A Control Operation The NG-2A controller has an LCD display and 3 buttons to access information and change parameters. UP SET DOWN The controller has two menus that limit access to relevant personnel. These being the Installer menu and Service Menu. 1.7 Installer Menu The Installer menu provides information and has parameters that can be controlled by the installer. On power up of the heater, the display will show HTG_OFF ng, if a Brivis Networker wall control is connected, and show SEARCH_nG if an analogue wall control is connected or if no wall control is connected. The installer menu is present as soon as the heater is powered up and initialised. The selection list can be scrolled through by using the SET button. The parameters can be changed by using the UP and DOWN buttons. The following table contains all parameters accessible in the Installers menu. Heater Parameter Table Order Display Appearance Description 1 2 H01 ID01:1000 HEATER MAXIMUM FAN SPEED SETTING The number displayed is the fan s default fan speed setting i.e. the RPM the fan is set to run at for normal heating operation. It can be adjusted between a maximum of 1350 and a minimum of 500, and should be set to meet the installation s airflow requirements. It is recommended to use a fan speed between 1000 to 1350, as lower speeds are more likely to result in overheat conditions if the system has not been balanced correctly. HEATING MINIMUM FAN SPEED SETTING For zoned heating systems this setting defines the minimum main fan speed. 3 H01 ID02:950 COOLING MAXIMUM FAN SPEED SETTING This displays the RPM the fan is set to run at for normal refrigerative cooling. It can be adjusted between a maximum of 1350 and a minimum of 500. H01 ID03: Issue 1 - Service Manual Heater BX5 March

13 4 COOLING MINIMUM FAN SPEED SETTING For zoned cooling systems this setting defines the minimum main fan speed. 5 H01 1D08:1000 HEATER IDENTIFICATION NUMBER (Do not alter unless multiple heaters are installed) This parameter is used to identify each heater in priority order when more than one heater is connected on the system H01 ID04:1 H01 ID05:500 H01 ID06:45 or H01 ID07:0 CIRCULATION FAN OPERATION This displays the RPM of the fan motor in circulation mode for fan operation between heating/refrigerative cooling cycles. E.g. when the system achieves the set room temperature and is cycled off by the thermostat, the heater s fan will continue to operate, to circulate the room air. SUPPLY AIR THERMISTOR SET POINT TEMPERATURE This displays the temperature the heater s gas valve will modulate to maintain. The default will vary across the different models, but it can be adjusted between 45º C and 70º C. This should be set to provide a comfortable outlet temperature. THE ZONING CONFIGURATION OPTION The zoning configuration option. When the NET516 module is detected as connected on startup NET516 is displayed. ZONE / REFRIGERATION MODE This is the selection mode for incorporating adaptive zoning and refrigeration onto the system. Parameter Value Description 0 No zone or add-on refrigeration 1 up to 2 On - board relays or 4 x 516 module relays can be used for Heating only zone control (Up to 2 with on-board or 4 with Module) 2 On-board or Brivis Network 516 module relays can be used for zone control (up to 2 on-board or 3 with Module) for heating and Add-On refrigeration. 3 Brivis Network 516 zone control (up to 3), for heating only 4 Brivis Network 516 zone control (up to 2), for heating and Add-On refrigeration. 5 Brivis Network 516 zone control (up to 4) for ref Add-On using on board relay. Note: All settings are saved automatically as you leave the set up mode. To leave the set up mode and return to normal operation, either leave the control untouched for 20 seconds, or keep pressing the SET button until the normal operation screen resumes, or press and hold the SET button for 3 seconds. Version 057 onwards of NG-2 will also include your request to have NG-2A display either NET506 or NET516 depending on module detected during power up. 279 Issue 1 - Service Manual Heater BX5 March

14 1.8 Service Menu The service menu can be accessed by following the instructions below: Ensure the LCD displays one of the following before commencing to the next sequence: Heat_##-# - when the heater is running, (where ##- # is the measured supply air temperature in C to one decimal place). HTG_OFF NG when the heater is in standby mode and a Brivis Networker wall control is connected. SEARCH_NG -- when the heater is in standby mode and an analogue wall control is connected. This can be achieved by entering a coded key sequence into the NG-2A control. The Service menu has three modes: Information, Error Log and Service Parameter. Each of these is explained below. To move through the different service modes, press the SET button. Use the UP and DOWN buttons to move through the selection list for each mode. Information Mode The information shown in this mode are the actual details from the sensors and components as they are operating, as distinct to how they have been set to operate. DRV = displays the modulating coil level based on a scale from GAS = 95 - displays the current in ma measured at the modulating coil. S -Air = displays the ACTUAL measured temperature at the supply air thermistor in C to one decimal place. PHASE = displays the current phase angle to the main fan motor. CIRC = displays the ACTUAL main fan RPM. Error Log Mode The Error Log displays the history of logged error information. It displays the details between 2 alternating screens, which includes the error code, time and day of the week when the error was logged ( d0 being Monday and d1 being Tuesday, and so on). Note: the Networker must be set to the correct date and time for the recorded details to be correct. The control has the ability to store 32 error messages (L0 - L31, where L0 is the most recent error, L1 the second most recent, and so on). Service Parameter Mode In Service Parameter mode the parameter number is displayed immediately following the "S" to the left of the LCD. The value of the parameter setting is to the right of the LCD, and can be adjusted by using the UP and DOWN buttons whilst the SET button is pressed. The changed parameter value is automatically saved when the next parameter is selected or the Service menu is exited. Be careful not to hold down the SET button for too long without using the UP and DOWN buttons as exit from the Service Mode will occur. Once all required changes have been made, exit the Service Menu by holding down the SET button for at least 2 seconds. A full list of service parameters are included below. 279 Issue 1 - Service Manual Heater BX5 March

15 Service Parameters Parameter Number Description Default Value Range S1 NG modulating coil minimum current level (ma) S2 NG modulating coil maximum current level (ma) S3 NG modulating coil ignition current level (ma) Factory Set: S7 Heating warm up cut off temperature ( C) S8 Cool down fan seed gradient time interval (ms) S9 Cool down cut off temperature ( C) BX S10 Internal add-on refrigeration relay used S11 LPG modulating coil minimum current level (ma). N/A S12 LPG modulating coil maximum current level (ma). N/A S13 LPG modulating coil ignition current level (ma). N/A Factory Set: S14 Cool down minimum temperature before fan cuts off BX S15 S16 This valve current defines the switching between high and low combustion fan speed (Zero means that the 2-speed function is disabled) (ma) This defines the delay time period between high and low combustion fan speed (ms) S17 Main fan phase control zero cross noise filter delay S18 Main fan phase control zero cross missed limit S19 Main fan phase control pulse triac cancel count setting S20 Main fan phase control triac pulse width S21 Main fan brake control S22 Boost control activation temperature difference ( C) S23 Gas control modulation boost control temperature ( C) S24 Heating boost control main fan speed offset (RPM) S25 Gas Control Modulation Current Stabilisation Time Interval S26 Rollout ignition de-bounce time interval (ms) S27 Rollout monitor de-bounce time interval (ms) S28 Report transient faults S29 Cooling LAT setting Issue 1 - Service Manual Heater BX5 March

16 S30 Cooling LAT setting Hysteresis S31 Cooling Lat trigger de-bounce time interval *Note: Ignition current level is tuned at EOL for each heater to ensure ignition gas pressure is to required level. 279 Issue 1 - Service Manual Heater BX5 March

17 2.0 COMPONENT OPERATION 2.1 Gas Valve The gas valves function is to provide gas for combustion. The gas valve is a Honeywell VK8105M gas valve, with electronic modulation, to vary the gas flow rate. It consists of two primary main solenoids which open and shut the gas valve, and an electronic modulating solenoid, to vary the gas flow rate. The gas valve is controlled by the NG-2A control. Modulation occurs when the thermistor that is located in the supply air duct reaches its desired set temperature the NG-2A control then varies the current (ma) through the modulation coil on the gas valve. 2.2 Burner The burners are known as In-shot burners. They consist of a venturi, which helps to draw air into the top of the burner, near the injectors. This is known as primary air and is used for gas mixing before combustion occurs. Once the gas and primary air leave the burner port, at the exit of the burner, combustion begins, and secondary air is added to the flame from the suction force developed from the combustion fan. There is a cross lighting gallery near the burner exit, which allows for cross ignition between each adjacent burner. 2.3 Spark Igniter The Spark Igniter consists of a spark probe and earth probe used to create a fixed spark gap (just like a spark plug on a combustion engine). The NG-2A control creates a high voltage through a sparker canister to generate a spark across this gap. This spark gap is located beneath the burner port at one end of the burner rack. Once ignition has occurred and the flame is sensed, the spark igniter stops sparking. 2.4 Flame Sensor The Flame Sensor consists of a single metal probe and is located beneath the burner at the opposite end of the burner rack from the Spark Igniter. When flame is present at this burner, a small electric current passes from the flame sensor through the flame to the closest ground point (either the Burner or Heat Exchanger). The NG-2A control monitors the Flame Sensor current level. If it is within an allowable range, then the controls allows for normal operation. If the current is too low, the gas valve will shut down. 2.5 Combustion Fan The combustion fans primary function is to pull air through the heat exchanger. This air is used to draw the flame into the heat exchanger inlet ports. It is also used to fuel the flames as they leave the burners. If this combustion airflow is reduced, the combustion quality will be reduced and sooting may occur. If the airflow is reduced considerably, then the flames will not be sucked into the heat exchanger and flames will rollout. Fortunately, there are measuring devices to prevent these occurrences from causing an unsafe condition. During start-up, the combustion fan performs a pre-purge for approximately 15 seconds. This ensures that there is no un-burnt fuel in the heat exchanger. During this phase, the required quantity of airflow for adequate combustion is confirmed by a vacuum pressure switch. If the airflow is not sufficient, then the vacuum pressure will be too low, and the pressure switch will not close, and a pressure switch error will be logged and no ignition will occur. 279 Issue 1 - Service Manual Heater BX5 March

18 During normal operation the vacuum pressure generated by the combustion fan is continually monitored by the pressure switch. If this vacuum pressure drops too low, then pressure switch will open, the burners will the shut down and an error will be logged. During a normal shut down sequence, the burners will shut down, and the combustion fan will switch off after 5 seconds. 2.6 Combustion Fan Speed Reduction The new SP Series heaters have increased efficiency and subsequently an increased star rating by introducing the two speed combustion fan. When the supply air thermistor has reached its desired temperature, which is determined by the set temperature on the NG2 board, the gas valve will modulate via the modulation coil on the gas valve. When the threshold current of 65mA is supplied from the NG2 to the gas valve the following occurs. 1. The NG2 board will open the 24volt on board air-conditioning relay 2. It sends the voltage signal to a 24volt to 240volt relay which enables the external mains 240volt to go through the power resistor (Ballasted) 3. This resistor is in series with the combustion fan motor coil reducing the effective voltage across the fan. 4. This will reduce the voltage which would slow the combustion fan down which slows the combustion gases within the heat exchanger. 5. This enables the heat to be transferred though the air stream of the heating unit and into the heated area. 2.7 Pressure Switch PRESSURE SWITCH: The pressure switch is a Cleveland NS2 series diaphragm pressure differential activated switch. For the location of these pressure switches refer below. Combustion Airflow Proving Switch The BX model has two pressure switches wired in series and both sensing from the one position on the flue fan chamber. The two pressure switches are rated at different pressures; the 115pa pressure switch is there to watch the flue fan vacuum when the combustion fan is running on high as described before. The 50pa pressure switch is there to sense when the flue fan switches down into the low fan speed. During this low fan speed state the pressure will fall below the 115pa threshold and it will open circuit, however the relay that switched the fan onto the low speed is also used to bypass the 115pa pressure switch. Refer to the wiring diagram page Issue 1 - Service Manual Heater BX5 March

19 2.8 Main Fan Assembly ROOM AIR FAN A centrifugal fan and Permanent Split Capacitor (PSC) motor, housed in a metal scroll are used for room air circulation. The room air fan is contained within the fan cabinet. A speed sensor mounted on the motor end plate provides speed feedback to the NG-2A control to maintain the required speed. The NG-2A also controls the timings for the room air fan operation. MOTOR: 20 kw models 315 watt PSC motor with 15µf capacitor and a 9"x7" centrifugal plastic fan wheel. FAN: 26 kw models 650 watt PSC motor with a 25µF capacitor and a 11"x10" centrifugal plastic fan wheel. 279 Issue 1 - Service Manual Heater BX5 March

20 2.9 Heater Start-up Flow Chart Heater switched on Combustion fan hold off (2 sec) Pressure Switch Closes Combustion Fan Prepurge (15 sec) Ignition Ignition retry phase activated Flame detect time Has flame been detected within 4.5 seconds? No Yes Flame validate time Has flame been present for 10 seconds? No Yes Initiate main fan hold-off time of 10 seconds. Run at minimum fan speed of 500 rpm Has supply air thermistor reached 40 C (Service parameter S7) within 120 seconds? No Fan speed ramps up Are all zones open or no zones programmed into Networker? No Yes Normal operation continues Thermistor limp mode activated. Heater runs at minimum gas pressure and maximum set fan speed during steady state operation. Yes Run at steady state fan speed (Installer parameter (1) Run at economy fan speed (Installer parameter (3) Steady state operation 279 Issue 1 - Service Manual Heater BX5 March

21 2.10 Heater Shut down Flow Chart Heater switched off Gas valve closes Yes Is supply air temperature below 50 C (Service parameter S9) No Combustion fan post-purge (5 sec) Yes Ramp down fan speed by 10 rpm every 0.5 seconds (Service parameter S8) until minimum fan speed of 500 rpm is reached. Minimum fan speed (500 rpm) Is supply air temperature below 41 C No Yes Main fan turns off 279 Issue 1 - Service Manual Heater BX5 March

22 3.0 INSTALLATION & COMMISSIONING REFER TO HEATING INSTALLER S MANUAL FOR INSTALLATION AND COMMISSIONING INSTRUCTIONS. 4.0 TROUBLESHOOTING Most failure modes will result in a fault code being logged in the NG-2A control. These faults can be viewed by entering the Service Menu. A brief description of each fault code is shown below, followed by detailed troubleshooting for each fault code. 4.1 Fault Code Summary Below is a list of fault codes to be used for diagnostics and troubleshooting. Fault Code Error 30 LCD Message Description While the main fan is operating the main fan speed sensing signal has been detected as incorrect for more than 200 seconds. Error 32 Board Failure: This fault indicates that parameter data in non-volatile memory could not be accessed and that all parameter data has been restored to default values. Error 33 Error 35 The feedback current from the gas valve modulating coil is not detected for at least the gas valve modulating coil fault delay time interval of 5 seconds even though a drive level is being applied to the coil. The supply-air thermistor has been detected as either open or short circuited for at least the supply-air thermistor fault delay time interval of 5 seconds. Error 36 Error 40 Error 41 Error 42 Error 43 The temperature registered by the supply-air thermistor did not reach the modulation set point temperature defined by installer setting number 6 within the main fan override time defined by factory parameter number 8. With this default value, during this stage of the thermistor cool down process the main fan will be ramped down by 10 rpm every 500 ms until the absolute minimum fan speed allowed is reached The combustion fan overheat switch has been detected as opened forcing the overheat cool down process to be initiated. So long as this switch remains open this fault condition is reported. The supply air overheat switch has been detected as opened forcing the overheat cool down process to be initiated. So long as this switch remains open this fault condition is reported. The supply air thermistor temperature has exceeded 90 C, forcing the overheat cool down process to be initiated. So long as this temperature is exceeded this fault condition is reported. The condition that has forced the overheat cool down process to be initiated has been removed with the remaining cool down process to be completed. Error 44 During an ignition at the FLAMEDETECT state or thereafter a flame rollout signal is detected and the maximum rollout events allowed has not been exceeded. The heating cycle is forced into its OFF state with a restart initiated. 279 Issue 1 - Service Manual Heater BX5 March

23 Error 45 Error 46 Error 47 Error 48 Error 49 Error 50 Error 51 Error 52 Error 53 Error 54 Error 55 Error 56 Error 57 Error 58 Error 60 The 24 VAC voltage level has dropped below the threshold level defined by factory parameter number 27 for at least the 24 VAC under threshold level delay time. A transient fault is registered (Code#45) indicating that heating cycle operation cannot be guaranteed with such a low voltage level. During an ignition attempt within the FLAMEDETECT state the flame signal is not detected within the flame detect time interval and the maximum attempts at flame detection during ignition have not been made. The heating cycle will be forced to its OFF state and a restart initiated. During an ignition attempt within the FLAMEVALIDATE state the flame signal is lost within the flame validate time interval and the maximum attempts at flame validation during ignition have not been made. The heating cycle will be forced to its OFF state and a restart initiated. During the ON phase of the heating cycle after the FLUEDELAY state has been processed the combustion chamber pressure switch has opened indicating a pressure loss with the maximum times this is allowed not exceeded. The heating cycle will be forced to its OFF state and a restart initiated. With the gas valve main coil energised flame has unexpectedly been lost, the heating cycle forced into its OFF state with a restart initiated. With no gas being expelled and no ignition source active a flame rollout signal has been detected indicating a problem with the flame rollout sensing circuitry. With no gas being expelled and no ignition source active a flame rollout signal has been detected indicating a problem with the flame rollout sensing circuitry. With no gas being expelled and no ignition source active a flame signal has been detected indicating a problem with the flame sensing circuitry. The number of overheat cool down procedures that have occurred in the cool down activation check time interval has exceeded the maximum allowed. During an ignition at the FLAMEDETECT state or thereafter a flame rollout signal is detected with the maximum rollout events allowed exceeded. The heating cycle is forced into its OFF state with no restart initiated. During an ignition attempt within the FLAMEVALIDATE state the flame signal is lost within the flame validate time interval with the maximum attempts at flame validation during ignition exceeded. The heating cycle will be forced to its OFF state with no restart initiated. With the combustion fan forced on a pressure switch is detected as open after the combustion fan delay time has expired, indicating that the switch is stuck off and did not close when the switch should. With the combustion fan forced off, the pressure switch is detected as closed indicating that the switch is stuck on and is not open when it should be. During the ON phase of the heating cycle after the FLUEDELAY state has been processed the pressure switch has opened indicating a pressure loss with the maximum times this is allowed exceeded. The heating cycle will be forced to its OFF state with no restart. A motor open circuit fault exists due to the NG-2A controller losing the AC voltage signal supplied to the motor. 279 Issue 1 - Service Manual Heater BX5 March

24 Error 61 Error 62 Error 63 Error 64 Error 65 Error 66 Error 67 Error 68 Error 69 Error 70 Error 71 Board Failure: On energizing the primary valve control relay its contact is not detected as closed within the primary valve control relay contact closed verification time) indicating that it is stuck off. Board Failure: With the primary valve control relay not being energized its contact is detected as closed indicating it is stuck on. Board Failure: While the primary valve control relay should be energized its contact is detected as opened by the primary microcontroller. The gas valve modulating coil current has been detected as exceeding the absolute maximum allowed (160mA) for at least the gas valve modulating coil fault delay time interval. While the fan limp fault is registered and a motor open circuit occurs or an overheat cool down is initiated the motor lockout fault is flagged. Board Failure: The secondary valve control relay contact was not detected as closed within the secondary valve control relay contact closed verification time indicating that it is stuck off. Board Failure: With the secondary valve control relay not being energized its contact is detected as closed indicating it is stuck on. Board Failure: While the secondary valve control relay should be energized its contact is detected as opened by the primary microcontroller. The 24 VAC voltage level has been lost completely possibly due to the 2A fuse being open circuited. Board Failure: This fault indicates that the secondary microcontroller did not shutdown the heating cycle within the heating cycle maximum shutdown delay time allowed in response to a fault condition detected by the primary microcontroller Board Failure: This fault indicates that the primary microcontroller detected an invalid heating cycle state being processed by the secondary microcontroller. The associated fault data value indicates the data value representing the heating cycle state that was detected as invalid. Note: Any further Error codes other than what has been specified are related to a NG-2A Board failure. 279 Issue 1 - Service Manual Heater BX5 March

25 4.2 ERROR 30 FAN_LIMP Reason: The NG-2A has not received the fan motor speed sensor signal required for normal operation. Limp Mode Operation The heater still operates with this error present, though the operation may not give the maximum or best performance. The unit will automatically operate at full fan speed. In FAN_LIMP the heater reverts to timing the ON and OFF fan operation with the fan speed at maximum. The fan ON time = 45 seconds from when the gas valve is energised at the start of the heating cycle. The fan OFF time = 60 seconds from when the gas valve closes at the end of the heating cycle. The fan will not vary speed, as the NG-2A has no fan RPM signal. Service Check List: Perform Fan Speed Sensor Test Check the speed sensor is correctly located in the hub of the motor end plate. Check that the speed sensor loom plug is correctly fitted on the NG-2A terminal marked "TACHO". Check the loom and the connection plug are not damaged. Remove speed sensor from motor end plate and check; That no foreign matter has entered the sensor cap. The sensor PCB is firmly secured within the sensor cap. The 2 sensor probes on the PCB are vertically aligned. The wiring circuit is not damaged. Check for a loose fan impellor on the motor shaft. Replace fan speed sensor Check and or replace the NG-2A module and retest. If all this fails replace NG-2A module and retest. 279 Issue 1 - Service Manual Heater BX5 March

26 4.3 ERROR 32 DATA_Err Reason: The NG-2A has failed to load data on power up, and has reverted to the Default settings. The heater may still operate with this error present. The unit may be used until a service technician attends. Service Check List: Reset the NG-2A module by temporarily changing any installer s parameter then move to the next parameter then back to the parameter and change back to its original value. Check the installer parameters. 4.4 ERROR 33 MDGV_LIMP Reason: The feedback current from the gas valve modulating coil is not detected for at least the gas valve modulating coil fault delay time interval of 5 seconds even though a drive level is being applied to the coil. Limp Mode Operation The gas valve modulating coil control reverts to open loop mode where the current level supplied to the modulating coil is fixed at 60 ma. Should the feedback signal become available the control reverts back to normal operation. Service Check List Loom connection is loose resulting in intermittent operation check loom continuity at PCB connector loom while still connected to gas valve. Wiggle the loom to check for poor connection. Loom is damaged resulting in intermittent operation check loom continuity at PCB connector loom while still connected to gas valve. Wiggle the loom to check for poor connection. Gas valve modulating coil is faulty check coil resistance is between 82 to C Poor connector on PCB check for looseness on the PCB. 279 Issue 1 - Service Manual Heater BX5 March

27 4.5 ERROR 35 No_SA-THM Reason: No_S-A_THM means the thermistor circuit is open circuit, and the NG-2A has not received the supply air thermistor sensor signal. Operation Mode: The heater still operates with this error present, though the operation does not give the maximum or best performance. The fan will be timed ON and OFF, operated at the installer set RPM, and the gas valve will be force to the minimum rate. The fan ON time = 45 seconds from when the gas valve is energised at the start of the heating cycle. The fan OFF time = 60 seconds from when the gas valve closes at the end of the heating cycle. Service Check List: Check the supply air thermistor has been installed, and that the loom and/or plug have been connected to the thermistor. Check the supply air thermistor wire loom has not been damaged. Check the thermistor is not faulty, check that the resistance is approx o C. 279 Issue 1 - Service Manual Heater BX5 March

28 4.6 ERROR 36 BadSA-THM Reason: BAdSA_THM means, the supply air thermistor has a circuit, but has not reached 30 o C. Within 2 minutes of the fan operation commencing, in a normal heating cycle. Operation Mode: The user still has some heating, until the problem can be rectified by a service technician, though the operation does not give the maximum or best performance. In BAdSA_THM fan operation, the unit cannot rely on the thermistor signal, and therefore operates the heater as follows: Fan operates at installer set speed, and the gas valve operates at minimum rate. The fan ON time = 45 seconds from when the gas valve is energised at the start of the heating cycle. The fan OFF time = 60 seconds from when the gas valve closes at the end of the heating cycle. Service Check List: Check the Supply Air Thermistor is installed in the Supply Air duct Check the thermistor is not faulty, check that the resistance is approx o C. Check the Supply Air Thermistor is not located in an unsuitable position within the Supply Air duct. 279 Issue 1 - Service Manual Heater BX5 March

29 4.7 ERROR 40 OHEAT_R-A 4.8 ERROR 41 OHEAT_S-A 4.9 ERROR 42 OHEAT_THM Reason: These errors will appear whilst an over temperature is current, the Over Heat Switch circuit is open, or the thermistor is measuring a temperature greater than 90 0 C. The heater's fan will be forced to operate at maximum speed and the combustion fan will also be operating. All StarPro models have a supply air over heat switch located near the supply air discharge and is activated before the supply air reaches 90 C. This switch triggers at 110 C. Brivis BX5 models are fitted with an additional over heat switch located in the combustion fan box to prevent the flue temperature exceeding 90 C. This switch triggers at 90 C. These switches directly interrupt the 24 Volt power to the gas valve if overheating occurs. If either or both over temperature switches open circuit indicating over temperature conditions within the Timed Safe Guard Period, then the following will occur during the over temperature condition: The power supply to the gas valve will be terminated. The fan will operate immediately, if not already operating. Once the over temperature condition has cleared and the switch resets, the normal heating cycle can commence again, provided the Networker is still calling for heat. The LCD will display "OHCooLDwn" for the next 60 seconds, alternating with the normal heating cycle displays i.e. HEAT= C 0. This is to indicate the heater has recently reset from an over temperature condition, but has now cooled sufficiently to resume operation: 279 Issue 1 - Service Manual Heater BX5 March

30 If the Networker turns the call for heat OFF whilst the unit is in over temperature during a normal heating cycle, then after completing the "OHCOOLDWN" 60 second period the fan will then resume the normal CooLDOWN of the heating cycle. I.e. CoolDOWN as in the normal heat cycle according to the supply air outlet thermistor temperature. Service Check List: Check the temperature registered at the nearest outlet to the heater, and compare this to the supply air thermistor temperature displayed on the NG-2A module. Check the temperature rise value of the supply air thermistor and nearest outlet temperature, over the room temperature (Return Air intake temperature). A 47 0 C. temperature rise will indicate a true overheat condition. Check there are sufficient outlets open on the duct system. Check the return air filter (if fitted) is sized correctly and is clean. Check that the fan speed is sufficient for the system so that overheating will not result. Check the fan motor is functioning correctly, and is not blocked or obstructed. Check the ducting has not been crushed, damaged or incorrectly sized. Check the return air intake is not subjected to a high temperature from an external source. Check that the supply air thermistor is correctly fitted in the supply air duct. Check the wire loom and plug connections to the switch are not open circuit, i.e. wire fallen off switch. Check the supply air thermistor circuit is not shorted together or earthed. Check the thermistor is not faulty, check that the resistance is approx o C. Check the link circuit on the NG-2A module between terminals 24 V. and STAT is open circuit 279 Issue 1 - Service Manual Heater BX5 March

31 4.10 ERROR 43 OHCooLDwn Reason: This error will be displayed during the 60 second maximum fan operation but is always logged following an over temperature error. Service Check List: Check the error log to determine what over heat error has occurred. Refer to Check List of the following error code for diagnosis: i.e. Error Code: 40 OHEAT_R-A, Error Code: 41 OHEAT_S-A, Error Code: 42 OHEAT_THM. Over heat switches Supply Air Overheat Switch Opening Closing 110 ±3.5 C 97 ±4.5 C 279 Issue 1 - Service Manual Heater BX5 March

32 4.11 ERROR 44 RoLLOut ERROR STAT Reason: During ignition a flame roll out has occurred where the flame has earthed the antiflame roll out (AFRO) bar to the burner assembly. This error display will only be seen on the display while the heater is currently recovering from conditions of flame sensed on the AFRO bar indicating a flame roll out. This is the 10 second shut down period of the gas valve, before the next re-ignition attempt. Service Check List: Operate the heater and observe the behaviour during ignition. Determine which AFRO is causing the roll-out. Rollout on lower AFRO During ignition, measure the ignition burner pressure and ensure it is within specification. Check that the correct injectors have been fitted and the gas type is correct. Check that the vacuum pressure switch is the correct switch and functioning correctly. Check for water gurgle noises being emitted from either the flue or the heat exchanger inlet ports (Water gurgle can be the result of premature condensation or a blocked condensate drain system on SP 6 models) Check if the flue terminal or flue pipe has soot marks, indicating poor combustion and/or a possible blocked heat exchanger. Rollout on Upper AFRO Check the burners for blockage. Check the burners for correct fitment. 279 Issue 1 - Service Manual Heater BX5 March

33 4.12 ERROR 45 LOW24VOLT ERROR Reason: The 24 volt circuit has been subjected to low voltage, resulting in insufficient 24 Volt output for reliable ignition or operation. This low voltage condition is usually only temporary and may be the result of a power loss or brown out. Service Check List: Check incoming power supply voltage (minimum 200 V). Check if power supply is not from a generator (may not be 50 Hz or might be wave rectified). Check if the 2 Amp fuse blown. Check the transformers secondary voltage output is within specifications. If the Network 506 is connected, check the current output on terminals 24 V and GND does not exceed 0.3 Amp's. 2.25A Transformer Transformer Voltage Nominal Voltage/ Maximum Current Secondary Voltage (No Load) (Red VAC Secondary Voltage (No Load) (Black VAC Secondary Voltage (No Load) (Red VAC 230 VAC / 2.25 A VAC VAC VAC 279 Issue 1 - Service Manual Heater BX5 March

34 4.13 ERROR 46 IGR_NOFLM Reason: This is a result of no flame being sensed by the flame sensor during the flame detect time interval of 4.5 seconds. A re-ignition will occur provided that the number of re-ignition attempts does not exceed 5 in a row. After 5 attempts an Error 50 will be logged and an Ignition Lockout will occur. Service Check List: Start up the heater and check for ignition. If ignition occurs and the heater losses flame within 4.5 seconds, then check the following: During ignition check if the burner flame ignites, but is not confirmed by the flame sensor (A flame symbol is displayed on the NG-2A LCD when flame is sensed). If the flame is not detected by the NG-2A control, then check the following: Check for correct connection of the flame sensor to the burner assembly and NG-2A control. Check for a satisfactory flame from the burner above the flame sensor. Check for continuity between the flame sensing rod and the lead connector. Check the flame sensor rod is located in the correct location as specified in Section 5.4. Check for correct ignition burner pressure as specified in Section 4.1 and adjust if required. Check power supply polarity is correct. Check the voltage to the gas valve is maintained (i.e. 24Vac) at back of NG-2A gas valve loom plug. A faulty connection may shut off the gas valve. Check the heater has been set for the correct gas type on the NG-2A bridge link. Clean the flame sensor rod and retry ignition. 279 Issue 1 - Service Manual Heater BX5 March

35 If ignition does not occur then check the following Check for sparking during the ignition process. Ensure that the spark canister is generating a spark signal and there is spark across the ignitor spark gap. Check the gas supply is turned ON at the gas meter, and the appliance gas cock. Check that the inlet gas pressure is sufficient during ignition (at least 800 Pa for ignition). Check that the burner pressure during ignition is within specification and adjust if necessary according to the procedure in section 5.1. If the correct burner pressure cannot be achieved: Ensure that the gas valve main coils and modulating coils are receiving sufficient voltage. If not then check the gas valve loom and connection on the NG-2A. Check the gas valve coil resistances are within specification: Gas Valve Modulating Coil maximum current Modulating coil winding 20 C Main Coil winding 20 C NG: 115 ma LPG: 160 ma Ω Coil 1: Ω Coil 2: Ω Check the air has been purged from the gas service piping. Check to make sure that the spark gap and location of the ignitor is within specification as described in Section 5.4. If the error cannot be eliminated after performing the above checks, then it may be possible that there is a fault with the gas valve or NG-2A control, and they should be changed individually to prove this. 279 Issue 1 - Service Manual Heater BX5 March

36 4.14 ERROR 47 IGR_BDFLM Reason: A flame has been detected by the flame sensor within the flame detect time of 4.5 seconds, and then the flame has been lost in the flame validate time (10 seconds after flame detection). If this failure occurs 5 consecutive times after an ignition attempt, then an Error 55 is registered and a lockout condition will occur. Once flame has been validated and ignition is successful, the failure count is reset. Service Check List: Operate the heater and observe the behaviour during ignition, in particular the behaviour of the flame at the burner near the flame sensor. During ignition, measure the ignition burner pressure and ensure it is within specification. Check that the correct injectors have been fitted and the gas type is correct. Too much gas flow during ignition can cause violent flame behaviour. Check that the vacuum pressure switch is the correct switch and functioning correctly. Check that the inlet gas pressure is sufficient during ignition (at least 800 Pa for ignition). Check for continuity between the flame sensing rod and the lead connector. Check the flame sensor rod is located in the correct location as specified in Section 5.5. Clean the flame sensor rod and retry ignition. 279 Issue 1 - Service Manual Heater BX5 March

37 4.15 ERROR 48 LOST_PRES Reason: During the ON phase of the heating cycle after the FLUEDELAY state has been processed the pressure switch has opened, indicating a pressure. The heating cycle will be forced to its OFF state and a restart initiated. If this occurs for 5 consecutive times, the Error 58 Pressure Fail will occur and a manual reset will be required. Service Check List: Vacuum Pressure Checking Procedure Measure vacuum pressure at each pressure switch during normal operation. Monitor the vacuum pressure overtime, as it may fall to a level close to the vacuum pressure that will cause the switch to become open circuit. If vacuum pressure is above specification (All pressure switches) If the vacuum pressure is above the pressure switch s specified value and Error 48 still occurs, then the pressure switch may be faulty and should be replaced. If vacuum pressure is below specification (All pressure switches) Vacuum pressure hoses are not fitted correctly check hose connections. Vacuum pressure hoses have perished and cracked causing vacuum pressure loss check for deterioration. Water trapped in the vacuum pressure hose check for water traps or presence of moisture in hoses. Excessive heat exchanger leakage resulting in vacuum pressure loss check heat exchanger for leakage. If vacuum pressure is below specification (Combustion fan box pressure switch) Flue piping is too restrictive check against allowable flue pipe configuration specification. Flue pipe has collected excessive condensate check for potential collection points (there must be a continual fall back to the heater). If vacuum pressure is below specification (Condensate tank pressure switch SP 6 models only) Condensate tank is not draining properly check drain, check for gurgle noise coming from SP 6 inlet ports. Intermittent failures It is possible that under sever wind conditions that excessive back pressure may cause this error to be logged, particularly on external models). It may also be the result of a blocked condensate drain, but may not be present at the time of servicing due to evaporation within the condensate drain line. 279 Issue 1 - Service Manual Heater BX5 March

38 4.16 ERROR 49 LOST_FLME Reason: During normal operation after ignition has been validated, if the flame sensor signal has unexpectedly been lost, the heating cycle is forced into its OFF state with a restart initiated and an Error 49 logged. Service Check List: Check gas supply pressure is not too high or low. Check the burners and injectors are clean, producing a properly formed flame. Check the flame sensing rod is clean, and correctly located as specified in section 5.5. Check for damage or loose connections to the burner flame sensor lead and connector. Check the minimum burner pressure is not below the minimum allowable level. Check the gas valve is providing a continuous steady gas flow to the main burner. Check there is no air disturbance to the burner flames (i.e. fan operation, wind etc.) ERROR 50 IGN_LKOUT Reason: This error code indicates the unit has locked out after 5 ignition attempts without the flame being recognised by the flame sensor. Service Check List: Refer to Check List for Error Code 46: IGR_NOFLM. 279 Issue 1 - Service Manual Heater BX5 March

39 4.18 ERROR 51 RLT_NOGAS Reason: This error indicates that the AFRO circuit has detected a flame rollout while the gas valve is not energised, and flame is not expected. Service Check List: Check that the pilot AFRO bar or wiring is not shorted to Earth. Check if a flame is present with the unit turned OFF. Check the gas valve is not jammed open due to malfunction, obstruction or blockage. Check if the 24 Volt power supply to the valve has been turned OFF, as expected in the normal operation ERROR 52 FLM_NOGAS Reason: This error indicates that the burner flame has been detected by the flame sensor when the gas valve is not energised, and flame is not expected. Service Check List: Check the pilot burner and/or burner main flame sensor lead is not shorted to Earth. Check if the burner flame is present with the unit turned OFF. Check the gas valve is not jammed open due to malfunction, obstruction or blockage. Check if the 24 Volt power supply to the valve has been turned OFF, as expected in the normal operation. 279 Issue 1 - Service Manual Heater BX5 March

40 4.20 ERROR 53 OH_LKOUT Reason: This error indicates the unit has had 2 consecutive over temperature conditions, within 15 minutes, after the wall controller is turned OFF and cool down has been completed. Refer to Check Lists for: Error Code 40: OHEAT_R-A Error Code 41: OHEAT_S-A Error Code 42: OHEAT_THM Service Check List: Check if the unit has been operating on a hot day following a power up. Check if the unit is ceiling mounted with a high level return air grille. Check that the fan speed is sufficient for the system so that over heating will not result. Check the fan motor is functioning correctly, and is not blocked or obstructed. Check the unit is not operating in FAN_LIMP mode. Check the gas valve is not jammed open and passing gas when not energised. Check the return air intake is not subjected to high temperature from an external source (i.e. not typical domestic system). Check the wire loom and plug connections to the switch are not open circuit, i.e. wire fallen off switch. Check that the supply air thermistor is not incorrectly fitted in the return air duct. SEE NEXT PAGE FOR OVER TEMPERATURE WITH NETWORKER OFF 279 Issue 1 - Service Manual Heater BX5 March

41 ERROR 53 (Cont) Over Temperature with Networker OFF If an over temperature condition is detected within the Timed Safe Guard Period with the Networker turned OFF, then the fan will start. The LCD for the over temperature switch will display the appropriate switch, until the fan cools the over temperature condition. The LCD will again display "OHCooLDwn" while the fan continues a 60 second fan OFF cycle. If a SECOND subsequent over temperature condition with the Networker OFF is detected, within the Time Safe Guard Period, the controller will again follow the same sequence for an over temperature condition. However, it will go into an Over Heat lockout mode that will require a reset (Reset at the Networker or SET button at the N-G2 module) to restore the unit to normal operation. If an over temperature condition occurs while the unit is in an over heat lockout mode, then the fan will be brought ON for the duration of the over temperature condition, followed by a 60 second fan OFF cycle period ERROR 54 RoL_LKOUT Reason: This error indicates the unit has locked out, due to 3 consecutive flame roll outs detected, within a heating cycle. Service Check List: Refer to Check List for Error Code 44: RoLLOuT. 279 Issue 1 - Service Manual Heater BX5 March

42 4.23 ERROR 55 IGINVALID Reason: This error indicates the unit has locked out, due to 5 consecutive flame losses (Error 47) during the flame validation stage. Service Check List: Refer to Check List for Error Code 47: IGR_BDFLM. 279 Issue 1 - Service Manual Heater BX5 March

43 4.24 ERROR 56 PRES_STOF Reason With the combustion fan forced on the combustion chamber pressure switch is detected as open after the combustion fan delay time of 15 Seconds has expired indicating that the switch is stuck off and did not close when it should. On BX5 models, this could be caused by either pressure switch not closing. This may be caused be insufficient vacuum pressure to close the pressure switch Service Check List Vacuum Pressure Checking Procedure (All pressure switches) Measure vacuum pressure at each pressure switch during pre-purge (or force an overheat condition, by breaking the overheat switch circuit, to operate the combustion fan). Perform these pressure checks without the pressure switch connected to the pressure hose. If vacuum pressure is above specification (All pressure switches) If the vacuum pressure is above the pressure switch s specified value and Error 56 still occurs, then the pressure switch may be faulty and should be replaced. If vacuum pressure is below specification (All pressure switches) Vacuum pressure hoses are not fitted correctly check hose connections Vacuum pressure hoses have perished and cracked causing vacuum pressure loss check for deterioration. Water trapped in the vacuum pressure hose check for water traps or presence of moisture in hoses. Make sure there is no water in the hose when servicing the system. Excessive heat exchanger leakage resulting in vacuum pressure loss check heat exchanger for leakage. Combustion fan may be faulty check according to procedure in section (Combustion Fan) If vacuum pressure is below specification (Combustion fan box pressure switch) Flue piping is too restrictive check against allowable flue pipe configuration specification including the flue cowl. Flue pipe has collected excessive condensate check for potential collection points (there must be a continual fall back to the heater 20mm rise per Metre). 279 Issue 1 - Service Manual Heater BX5 March

44 4.25 ERROR 57 PRES_STON Reason: With the combustion fan forced off, the pressure switch is detected as closed indicating that the switch is stuck on and is not open when it should be. This error will occur prior to pre-purge when the NG-2A control checks to ensure that the pressure switch/switches are open before operating the combustion fan. Service Check List: Vacuum Pressure Checking Procedure Measure vacuum pressure at each pressure switch without any combustion fan operation. If vacuum pressure is below the pressure switch closing specification (All pressure switches) If the vacuum pressure is below the pressure switch s specified closing value and Error 57 still occurs, then the pressure switch may be faulty check the switch for continuity and if it is closed with low vacuum pressure (below specification, or no pressure at all) then it should be replaced ERROR 58 PRES_FAIL Reason: During the ON phase of the heating cycle after the FLUEDELAY state has been processed the pressure switch has opened indicating a pressure loss (Error 48) 5 consecutive times. The heating cycle will be forced to its OFF state with no restart. A restart will only occur from a manual reset including a power reset. Service Check List: Check that the condensate drain has a continual fall away from the heater and does not contain water. Check that the condensate pipe length is correct length. Refer to Check List for Error Code Issue 1 - Service Manual Heater BX5 March

45 4.27 ERROR 60 MOTOR_O-C ERROR Reason: This error code indicates the main fan motor is "open circuit". Service Check List: Check the wiring to the motor, and the plug connections are connected satisfactorily. Check for signs of damage to the motor loom or motor extension loom Check that the motor winding resistances are within specifications as shown below. (Note: The resistances specified are when the motors winding temperatures are at 20 C, and will vary if the motors temperature is hotter or cooler). Start Winding 20 C Main Winding 20 C Fasco 315W 80855BNVA-A20 Fasco 650W 80855BPVA-A Ω Ω Ω Ω Check if the motor casing is HOT, indicating the motor's thermal over temperature switch may be tripped. If the motor is hot: Check motor bearings for wear and stiffness. Check the capacitor is the correct size and/or faulty. Check the fan impellor is not damaged, jammed, blocked or obstructed. Check the incoming power supply voltage. 279 Issue 1 - Service Manual Heater BX5 March

46 4.28 ERROR 61 PVCR-STOF Reason: This error code indicates on energising the primary valve control relay its contact is not detected as closed within the primary valve control relay contact closed and indicating that it is stuck off. Service Check List: If Error 61 has occurred in the past on this heater then replace the NG-2A Module For a first time Error 61 reset NG-2A Module then retry heater operation. If NG-2A cannot be reset or if Error 61 reoccurs then replace NG-2A module and retest ERROR 62 PVCR_STON Reason: With the primary valve control relay not being energised its contact is detected as closed indicating it is stuck on : Lockout Condition ( See Error Code#51) With the heating cycle in the ON PREIGNITION phase the status of a number of inputs is checked by the primary microcontroller. In particular: 1) The state of the flame rollout signal is monitored and if a flame rollout is detected as available this would suggest that the flame rollout sensing circuitry has failed as no flame should be available at this stage (gas valve main coil not energised). Subsequently, a lockout condition (Code#51) is registered forcing the heating cycle back to its OFF state with no post-purge. 2) The state of the primary valve control relay contact is monitored and if it is detected as closed when it should be opened this would suggest that the contact is stuck on as the relay has not been energised yet. Subsequently, a lockout condition (Code#62) is registered forcing the heating cycle back to its OFF state with no post-purge. 3) The state of the secondary valve control relay contact is monitored and if it is detected as closed when it should be opened this would suggest that the contact is stuck on as the relay has not been energised yet. Subsequently, a lockout condition (Code#67) is registered forcing the heating cycle back to its OFF state with no post-purge. 4) The state of the flame signal is monitored and if flame is detected as available this would suggest that the flame sensing circuitry has failed as no flame should be available at this stage (gas valve main coil not energised). Subsequently, a lockout condition (Code#52) is registered forcing the heating cycle back to its OFF state with no post-purge. Service Check List: Reset NG-2A Module Replace the NG-2A module 279 Issue 1 - Service Manual Heater BX5 March

47 4.30 ERROR 63 PVCR-FAIL Reason: While the primary valve control relay should be energised its contact is detected as opened by the primary microcontroller Once the state is entered the primary valve control relay contact state is continuously monitored by the primary microcontroller until the OFF state of the heating cycle is entered If the primary valve control relay contact is unexpectedly detected as opened by the primary microcontroller a lockout condition (Code#63) is registered by the primary microcontroller forcing the heating cycle into the OFF state. Service Check List: If Error 63 has occurred in the past on this heater then replace the NG-2A Module For a first time Error 63 reset NG-2A Module then retry heater operation. If NG-2A cannot be reset or if Error 63 reoccurs then replace NG-2A module and retest. 279 Issue 1 - Service Manual Heater BX5 March

48 4.31 Error 64 GAS_LKOUT Reason: If the supply-air thermistor is not available to provide the necessary feedback signal the gas valve modulating coil is provided with the minimum current drive level according to the gas type being used. This ensures that the heating operates, but at a safe level. While the gas valve modulating coil is being operated and the current through the coil is detected as exceeding the absolute maximum value of 160mA for at least the gas valve modulating coil fault delay, a lockout condition is registered (Code#64). Service Check List: If Error 64 has occurred in the past on this heater then replace the NG-2A Module For a first time Error 64 reset NG-2A Module then retry heater operation. If NG-2A cannot be reset or if Error 64 reoccurs then replace NG-2A module and retest ERROR 65 MTR_LKOUT Reason: The unit is locked out due to fan motor open circuit (Error 60), and the fan motor speed sensor signal has not been received by the NG-2A (Error 30). OR The unit was operating in FAN_LIMP mode (Error 30), and an over temperature condition has occurred (Error 40, 41, or 42). Service Check List: Refer to Check Lists for Error Code 30, 40, 41, 42 or 60, whichever has occurred. 279 Issue 1 - Service Manual Heater BX5 March

49 4.33 ERROR 66 SVCR_STOF Reason: The secondary valve control relay contact on the NG-2A was not detected as closed within the secondary valve control relay contact closed verification time indicating that it is stuck off If the secondary valve control relay contact is detected as closed within the allotted time, heating cycle control within the primary microcontroller proceeds to the next state FLAMEDETECT. Service Check List: If Error 66 has occurred in the past on this heater then replace the NG-2A Module For a first time Error 66 reset NG-2A Module then retry heater operation ERROR 67 SVCR_STON Reason: With the secondary valve control relay not being energised its contact is detected as closed indicating it is stuck on With the primary valve control relay contact detected as closed the secondary valve control relay contact has also been detected as closed even though the relay has not been energised yet. This indicates that the relay is stuck on. Service Check List: If error 67 has occurred in the past on this heater then replace the NG-2A Module For a first time Error 67 reset NG-2A Module then retry heater operation. 279 Issue 1 - Service Manual Heater BX5 March

50 4.45 ERROR 68 SVCR_FAIL Reason: While the secondary valve control relay should be energised its contact is detected as opened by the primary microcontroller. Once the FLAMEDETECT state is entered the secondary valve control relay contact state is continuously monitored by the primary microcontroller until the OFF state of the heating cycle is entered as is illustrated in the flow chart of FIG c. If the secondary valve control relay contact is unexpectedly detected as opened by the primary microcontroller a lockout condition (Code#63) is registered by the primary microcontroller forcing the heating cycle into the OFF state. Service Check List: For a first time Error 68 reset NG-2A Module then retry heater operation. Clean the flame sensor Clean the Ignitor spark plug Check the flame sensor location is correct See Flame Sensor servicing section in this manual (Do not reposition the flame sensor in the flame) Check and adjust the gas pressures which include Burner pressure, Minimum Burner pressure and Ignition Burner pressure. Check the gas valve loom and rectifier plug. Check the gas valve. Also See Errors: 46, 47, 49 and Issue 1 - Service Manual Heater BX5 March

51 4.46 ERROR 69 FUSE_BLOW Reason: This error code indicates the 2 Amp fuse on the NG-2A has blown due to a short circuit on the 24 Volt wiring circuit. Short Circuit Over Temperature Circuits If either the supply air Over heat switch is shorted to Earth, then the N-G2 2 Amp fuse will be blown: ERROR If either the return air or supply air switch is shorted together then the switch function is disabled. Service Check List: Check if the 24 Volt internal wiring circuit to the over temperature switches, pressure switch/s and gas valve is not shorted to Earth. Check that any wiring connected to the On-Board relays is not shorted to Earth. Check that any wiring connected to the 24V terminal is not shorted to Earth (i.e. Network 516 module as well as the wiring to the refrigeration compressor relay if applicable). Check the gas valve solenoid coil is not shorted. Low Voltage Fuse 24 VAC 2A Fuse 279 Issue 1 - Service Manual Heater BX5 March

52 4.47 ERROR 70 SS-SDNERR Reason: This fault indicates that the secondary microcontroller did not shutdown the heating cycle within the heating cycle maximum shutdown delay time (t sdndelay =2.5s) allowed in response to a fault condition detected by the primary microcontroller (See Section , , ). Service Check List: If error 70 has occurred in the past on this heater then replace the NG-2A Module For a first time Error 70 reset NG-2A Module then retry heater operation ERROR 71 SS-STAERR Reason: This fault indicates that the primary microcontroller detected a fault with heating cycle state timing within the secondary microcontroller with the associated fault data indicating which state was at fault (See Section ). Service Check List: If error 71 has occurred in the past on this heater then replace the NG-2A Module For a first time Error 71 reset NG-2A Module then retry heater operation. 279 Issue 1 - Service Manual Heater BX5 March

53 5.0 MAIN COMPONENTS SERVICING This section contains the procedures for checking and adjusting (if necessary) main components of the heater. This may be required due to a failure or a routine service. 5.1 Gas Valve Servicing The diagram below indicates the measurement and adjustment locations. If adjustment to the gas valve is required, a 8mm and 5mm spanner, or small size adjustable wrench will be required. Maximum Pressure Adjustment Screw Minimum Pressure Adjustment Screw Burner Pressure Test Point Inlet Gas Pressure Test Point Gas Valve Modulating Coil maximum current Modulating coil winding 20 C Main Coil winding 20 C NG: 115 ma Ω Coil 1: Ω Coil 2: Ω Refer to section Technical Sheet for gas pressure readings. 279 Issue 1 - Service Manual Heater BX5 March

54 5.2 Gas Valve Checking and Adjustment (only if required) To check for correct gas valve settings and operation the following should be performed, and adjustments made when necessary. Inlet Pressure Measurement Loosen the gas inlet test point screw, located on the gas valve as shown in the diagram, and connect a suitable manometer to the test point. Turn on the heater and wait for the flame proving period to finish. Check that the inlet gas pressure is between 1.1 kpa to 3.5 kpa. Pressures below this level can result in incorrect checking and adjustment of the gas valve. If this is the case then this situation should be rectified. Remove the manometer and retighten the inlet test point screw immediately to prevent gas leakage. Low Inlet Pressures It is possible that low inlet pressure can cause: Unreliable ignition if the inlet pressure is below 0.80 kpa at the time of ignition. Underrated heat output Burner Pressure Measurement Loosen the burner pressure test point screw, located on the gas valve as shown in the diagram, and connect a suitable manometer immediately (Note: The heater can still be running from the previous step before loosening the test point). Maximum Burner Pressure Checking Force the gas valve to drive the modulating coil to the maximum level by setting the service parameters as follows. Natural Gas LPG S1 115 S S2 115 S The maximum burner pressure can now be checked. If the burner pressure is within ±30 Pa of the specified maximum burner pressure, no adjustment is required. If adjustment is required, adjust the maximum burner pressure setting screw on the gas valve (clockwise increases pressure). Minimum Burner Pressure Checking Force the gas valve to drive the modulating coil to the minimum level by setting the service parameters as follows. Natural Gas LPG S1 30 S11 45 S2 30 S12 45 The minimum burner pressure can now be checked. If the burner pressure is within specifications (Refer to Technical Information section 1.1), no adjustment is required. If adjustment is required, adjust the minimum burner pressure setting screw on the gas valve (clockwise increases pressure). Note: If operating at the minimum burner pressure for greater than x minutes, then temporarily set the Heat fan speed in the Installer menu to 500 RPM. This will prevent premature 279 Issue 1 - Service Manual Heater BX5 March

55 condensing occurring inside the heat exchanger in non-condensing regions during this procedure. Reset the Heat fan speed back to the previous value. Once the minimum pressure has been set, force the gas valve to operate at high burner pressure as described above under Maximum Burner Pressure Checking, to make sure that the maximum burner pressure is still within specifications. Once both the maximum and minimum burner pressures have been checked, and adjusted if required, set the service parameters back to the default values as follows: Natural Gas LPG S1 30 S11 45 S2 115 S LPG will be made available in 2014 If the gas valve cannot be set to the specified maximum and minimum burner pressures, then the gas valve will have to be replaced. Refer to section 6.3 for gas valve removal. Ignition Burner Pressure Checking If there have been any errors caused by unsatisfactory ignition, such as Error 46, 47, 50, 86 and 55, then it is important that the ignition burner pressure is checked. This can be performed by measuring the burner pressure immediately after ignition has occurred. If ignition does not occur, measure the burner pressure near the end of the sparking period. The ignition burner pressure should be within the range specified in the table below. Ignition Burner Pressure refer to EOL sheet If adjustment is required then the following procedure should be performed: Force the gas valve to drive the modulating coil to the minimum level by setting the service parameters as follows. Natural Gas LPG S1 30 S11 45 S2 30 S12 45 LPG will be made available in 2014 Now increase service parameter S2 for Natural Gas models, until the gas pressure is within the limits as specified in the Ignition Burner Pressure table above. The value that S2 for Natural Gas had to be set to obtain an acceptable ignition burner pressure is to be used to set the Ignition Burner Current parameter (S3 for Natural Gas). Once the ignition gas pressure current is set, set the service parameters back to the default values as follows: Natural Gas LPG S2 115 S LPG will be made available in Issue 1 - Service Manual Heater BX5 March

56 5.3 Combustion Fan Servicing General Service 1. Check that the motor s shaft spins freely. 2. While in operation during a prepurge, check for any unusual noise, such as bearing or scraping noise. (Note: The presence of a tinkling sound can be caused by the impellor removing water particles out of the fan housing, which should not be present on BX5 models). If there is any suspicion of an underperforming combustion fan or that the entire system is resulting in low vacuum pressure, the following should be performed: 1. Isolate the heater s power supply. 2. Check the motor s winding resistance with the wire looms removed. 3. Re-insert the motor s wiring loom. 4. Connect a manometer into the combustion fan vacuum pressure hose to measure the vacuum pressure just prior to the combustion fan. 5. Re-apply power to the heater and force it into an overheat mode to power up the combustion fan. (Warning: Remember the motor operates with 240 Vac.) 6. Measure the combustion fan vacuum pressure, and ensure that it reaches the value as specified in the table below. Voltage/Power 230 VAC / 60 W Combustion Fan Winding 20 C Ω See Heater vacuum pressures in pressure switch section 5.5 Technical Data sheet. If the vacuum pressure is below the specified values: 1. Check that the flueing is within the allowable specifications. 2. Look for any physical causes of underperformance such as the build up of soot or silicon in the combustion fan housing or flue pipe. Clean if necessary. Servicing while removed It may be required to remove the combustion fan to inspect it totally or to try a new combustion fan. Refer to section 6.5 for removal procedure of the combustion fan removal. Ballasted resistor readings and combustion fan speed. COMBUSTION FAN SPEED UNIT RESISTOR (Ohm) HIGH LOW BX BX Issue 1 - Service Manual Heater BX5 March

57 5.4 Spark Igniter Servicing Isolate the heater power and gas supply from the unit. Checking the Spark Ignitor Unscrew the spark igniter away from the burner Check Spark Igniter electrode, lead and plug connection Clean igniter probe and make sure there is a spark gap of approx 4 mm. Then reassemble. Checking Spark Igniter location relative to burner face Remove the burner assembly as described in section 5.1 Measure the distances as shown in the diagram below. Installation is a reversal of the removal procedure. 11±1.5 mm 8.5±1.5 mm Sparker probe end is in alignment with burner centreline ±2 mm. 279 Issue 1 - Service Manual Heater BX5 March

58 5.5 Flame Sensor Servicing Isolate the heater power and gas supply from the unit. Checking the Flame Sensor Check that the Flame Sensor rod is clean, located correctly and the lead and plug connection is in good condition. Reassemble. Checking Flame Sensor location relative to burner face Remove the burner assembly as described in section 5.1 Measure the distances as shown in the diagram below. Installation is a reversal of the removal procedure. Please ensure that the flame sensor are located in this configuration below 12±2 mm 11±2 mm Flame sensor readings Pre Puge Nichrom flame sensor (µa) AC Spark & flame confirmation At max Gas rate At 1min Max gas Issue 1 - Service Manual Heater BX5 March

59 5.6 Pressure Switch Servicing Make sure the vent hole and bleed hole are clear of any foreign material. Make sure the hoses are free of condensation. Check the hoses leading to the pressure switch are not split or damaged Reassemble. Measure the vacuum pressure Isolate the heater power and gas supply from the unit. Tap into the pressure switch line with a suitable manometer. Check that the pressure switch is opening within the limits specified below as follows: Pressure Switch Settings BX520 and BX526 Model Product Numbers Max Combustion Fan Pressure Switch Opening Vacuum Pressure (-Pa) Nom. Limit Min Limit Max Min Condensate Fan Pressure Switch Opening Vacuum Pressure (-Pa) Nom. Limit Min Limit Max Maximum Pressure Switch Closing Vacuum Pressure (Pa) NG BX520 BX526 B B Nom. Opening Vacuum Pressure + 20 Pa vacuum Vent Hole (2.3 mm) Bleed (0.4 mm) Hole 279 Issue 1 - Service Manual Heater BX5 March

60 5.7 Main Fan Assembly Servicing External Models Turn the unit OFF and isolate the power supply. Remove the main fan assembly as described in Section Check for any signs of wear Rotate the fan wheel and check for any irregular noise such as scraping or worn bearings. Clean impellor and motor. Clean housing. Clean heater's fan compartment inner lining. Reassemble. Check all wiring cables and plug connections (including speed sensor). Installation is a reversal of the removal procedure. Model Fasco 315W BNVA-A20 Fasco 650W BPVA-A12 Power 315 W 650 W Maximum Current 4.2 A 4.3 A Main Fan Motor Capacitor 15±1.5 µf 25±2.5 µf Start Winding 20 C Ω Ω Main Winding 20 C Ω Ω Impellor Size - diam. x width 225 x 180 mm 284 x 265 mm 5.8 Unit operation 1. Check power supply lead is in good condition. 2. Check all gas connections are good and do not leak. 3. Check the Networker wiring connection at the unit is in good condition. 4. Check the burner's maximum and minimum operating gas pressure on the test point provided on the gas valve. 5. Check the transformer operation (check for vibration) 6. Check the duct system airflow distribution, balance and adjust as required. 7. Check the unit's selected fan speed (RPM) is appropriate for optimum heat output for the application. 8. Check other accessories fitted to the system (i.e. Network 516, zone dampers) are functioning. 279 Issue 1 - Service Manual Heater BX5 March

61 5.9 Transformer Voltages and resistance 2.25A Transformer Nominal Voltage/ Maximum Current Secondary Voltage (No Load) (Red VAC Secondary Voltage (No Load) (Black 230 VAC Secondary Voltage (No Load) (Red 230 VAC 230 VAC / 2.25 A VAC VAC VAC If there is a humming transformer a rubber insulator can be placed behind the transformer. The frame of the transformer is the earth connection which is required to be earthed. Place a wire from the supporting screw that holds the transformer in place to the earth point on the heater Components on the BX5 Series Fuse 24Vac 24 VAC 2A Fuse Fuse 240 VAC Supply Air Duct Thermistor 250 VAC 8A Slow Blow Fuse 10k 25 C 279 Issue 1 - Service Manual Heater BX5 March

62 6.0 REMOVAL PROCEDURES Before any of the following assemblies or components can be removed, it is important to isolate the heater s power and gas supply. The heaters roof will also have to be removed by removing 2 screws at each end of the roof. Internal heaters have a top wrap around the service chamber that can be removed for easier access, if required by simply removing the 10 screws off the top wrap. 6.1 Burner Assembly Removal 1. Turn the gas isolation valve off and isolate the heater s power supply 2. Remove the gas valve loom; spark igniter lead, flame sensor lead and AFRO wire from the NG-2A PCB. 3. Remove the gas inlet pipe off the gas valve and move the piping enough to enable the burner assembly to be removed when ready. 4. Remove the gas valve support bracket screw from the heat exchanger main plate, and then remove the bracket. 5. Remove the 4 screws holding the burner assembly to the heat exchanger main plate. 6. The burner assembly can now be removed. Installation is a reversal of the removal procedure with attention to the following points: 1. Ensure that the gas inlet feed-tube is retightened and checked for leaks. 2. Ensure that all looms, wires and leads are not damaged along their length and at the connectors. 6.2 Gas Manifold Assembly Removal 1. Turn the gas isolation valve off and isolate the heater s power supply 2. Remove the gas valve loom from the NG-2A PCB. 3. Remove the gas inlet feed-tube off the gas valve. 4. Remove the gas valve support bracket screw from the heat exchanger main plate, and then remove the bracket. 5. Remove the 4 screws holding the gas manifold to the burner assembly. 6. The gas manifold assembly can now be removed. Installation is a reversal of the removal procedure with attention to the following points: 1. When re-inserting the assembly, ensure that the injectors are inserted into the ring on the top of the burners correctly. Ensure that the gas inlet feed-tube is retightened and checked for leaks. 2. Ensure that the gas valve loom is not damaged along its length and at the connector. 279 Issue 1 - Service Manual Heater BX5 March

63 6.3 Gas Valve Removal 1. Turn the gas isolation valve off and isolate heater s power supply Disconnect the gas valve rectifier and loom. Remove the gas inlet feed-tube off the gas valve. Remove the gas valve support bracket screw from the heat exchanger main plate, and then remove the bracket. Remove the gas valve from the burner manifold by unwinding it in an anti-clockwise direction. Remove the brass adaptor on the gas valve inlet side of the gas valve if the valve is to be replaced. Installation is a reversal of the removal procedure with attention to the following points: 1. Clean any threads of excessive gas thread sealant, which are to be re-assembled 2. If a new gas valve is to be fitted, apply gas thread sealant to the brass adaptor and fingertighten onto the gas valve. 3. Apply gas thread sealant to the burner manifold feed tube nipple and screw on the gas valve, and then tighten. Check for leaks on both sides of the gas valve while in operation. If a new gas valve is fitted, ensure that it is reset, including the ignition gas pressure, as outlined in section Pressure Switch Assembly Removal The BX5 models have 2 pressure switches 1. Isolate the heater s power supply. 2. Remove the hose from the pressure switch. 3. Remove the electrical wires on the pressure switch. 4. Remove the pressure switch bracket screws on the heat exchanger, and then the complete assembly can be removed. 5. Remove the pressure switch fastening screws if the pressure switched are to be replaced. Installation is a reversal of the removal procedure with attention to the following points: 279 Issue 1 - Service Manual Heater BX5 March

64 6.5 Combustion Fan Removal Method 1 Partial Fan Removal 1. Isolate the heater s power supply. 2. Remove the electrical lead off the NG-2A board. 3. Remove the flue coupling connected to the combustion fan outlet. 4. Remove 3 screws which fasten the combustion fan down to the combustion fan box. 5. Pry the combustion fan off the box, which will still be fastened by the sealing silicon. Installation is a reversal of the removal procedure with attention to the following points: 1. Fasten both halves together with correctly sized cir-clips or e-clips, if the original spring clips are too difficult to fit. Method 2 Complete Fan Removal 1. Isolate the heater s power supply 2. Remove the electrical lead off the NG2 Board 3. Remove 3 screws which fasten the combustion fan down to the combustion fan box. 4. Pry the combustion fan off the box, which will still be fastened by the sealing silicon. Installation is a reversal of the removal procedure with attention to the following points: 1. Clean both surfaces to be re-mated together. 2. Apply sufficient (but not excessive) silicon to the combustion fan s mating surface. 6.6 NG-2A Electronic Control Board Removal 1. Isolate the heater s power supply. 2. Remove the spark igniter lead from the PCB assembly. 3. Remove the 240 volt cover screw, and then manoeuvre the 240 volt plastic cover from the PCB assembly. 4. Remove the screws securing the main plastic control board cover and remove. 5. Remove all other electrical connections from the PCB assembly. 6. Remove the 2 screws that secure the PCB assembly to the NG-2A support bracket. WARNING: Care should be taken to prevent any damage of the wiring and PCB. Installation is a reversal of the removal procedure with attention to the following points: 1. Ensure all wiring connections are positively located and that no looms have been damaged. NOTE: Please ensure that the Natural Gas and LPGas Bridge is removed for Natural Gas model. See location pin on PG2 on the NG-2A board. 279 Issue 1 - Service Manual Heater BX5 March

65 6.7 Heat Exchanger Removal 1. Isolate the heater s power supply. 2. remove the surround wrap around the service chamber 3. Remove the gas train assembly as described under section Remove the Gas manifold 5. Remove the pressure switch assembly as described under section Remove the NG-2A PCB assembly and NG-2A support bracket (refer to the NG-2A control board removal section for further instructions). The NG-2A support bracket has 3 screws which fasten it to the heat exchanger main plate, which will have to be removed. 7. Remove the supply air duct and remove the condensate hose from inside the unit. 8. Remove the heat 6 screws which hold the heat exchanger down within the cabinet area 9. The heat exchanger can be raised out from the top. 10. If wanting the Heat exchanger to come out of the end of the unit the removal of the supply air duct is required as well as removing the end panel off which the heat exchanger can slide out of the end of the unit. 6.8 Ballast resistor and loom Removal 1. Isolate the heater power supply 2. Remove the 2 wires connected to the NG2A board Add - On relay 3. Remove the 2 screws holding the Ballast resistor to the top of the heat exchanger plate or the fan housing top plate pending on the model of unit. 5. Remove ballast resistor and loom as one 6. Replace in reverse order. Ballast Resistor Wiring loom 279 Issue 1 - Service Manual Heater BX5 March

66 6.9 Flue Pipe Removal BX5 External Models Loosen the Flue pipe hose clamps on the flue coupling at the combustion fan outlet as shown below. Remove the flue terminal and then remove the flue pipe from the heater. Flue Piping Combustion fan assembly Rubber coupling and pipe clamps When placing it back into place please make sure that it is sealed tight and no flue gases can escape from the connection. 279 Issue 1 - Service Manual Heater BX5 March

67 6.10 Main Fan Assembly Removal External Models 1. Turn the unit OFF and isolate the power supply. 2. Remove the heater lid by unscrewing the 4 self tapping screws on the cover then lift the cover off. 3. Remove the flue pipe assembly as described in Section Remove the fan electrical power loom and speed sensor off the NG-2A. 5. Remove the thermistor loom off the NG-2A 6. Remove the screws that hold the top plate to the cabinet. 7. Remove fan housing from cabinet. Installation is a reversal of the removal procedure. Motor and Plate Removal 1. Remove the screws that attach motor plate to the fan scroll then remove the motor plate, motor and fan wheel assembly from the fan scroll. 2. Remove the fan from the motor by loosening the grub screw from the motor shaft. If the fan wheel is ceased onto the motor shaft then WD-40 and a puller may be required. 3. The motor may be removed from the motor plate if required by removing the bolts and nuts that secure the motor to the motor stator brackets. 279 Issue 1 - Service Manual Heater BX5 March

68 7.0 Brivis Acc Network 516 Module Low - Voltage Suitable for all Brivis BX5, SP4, SP5 and SP6 Internal / External Ducted Gas Heaters This module CANNOT be used on any other model. The Network 516 Zone Module is required to be used on StarPro units with software higher than Version 50 on the NG-2A Control Board. The Network 516 Module requires a 240 volt power supply that can be plugged in to via a 3 pin fixed switched power socket. A pre-wired loom is provided to connect to the heaters electronic control board (NG-2A), as is a 25mm electrical conduit to accommodate the zone motor wiring. Ensure the Network 516 mounting position, is within reach of the loom length (1 metre), for the connection to the heater as well as the power supply point (1.5 metre). The 516 module shall be screwed to the heater cabinet. The conduit saddle provided should be used to secure the 25mm conduit to the cabinet back, and protect the 24 Volt zone motor wiring. Brivis Zone plus All SP series heaters with a serial number great than are Zone Plus Compatible. The Brivis ZonePlus allows you to have up to four individually controlled zones, each with their own time and temperature settings. For total flexibility, you can upgrade as many Brivis Temperature sensors to Brivis networkers allowing you to fully control, program and manage each zone eliminating the need for you to go back to the Master Networker. Adjust temperatures for each zone as it suits you from any Networker in the home. Perfect comfort, absolute control. The Brivis ZonePlus works in unison with any Brivis Ducted heater with, BX5, 4, 5 and 6 Star efficiency. 279 Issue 1 - Service Manual Heater BX5 March

69 Network 516 Mounting positions External models: Mount the Network 516 on the cabinet end, and secure the conduit with the saddle at the back of the unit. Trim and seal the unit's flashing strip around the 25mm conduit to protect the wiring from the weather. Internal models: Mount the Network 506 on the cabinet end, alternatively, the Network 516 can be mounted on adjacent structural members. Wiring the Network 516 to the Heater Route the Network 516 loom to the heaters electronic control module NG-2A using the grommet on the loom where the entry is made into the heaters cabinet. Connect the 6 pin plug to the terminal marked "Option Board" at the NG-2A. Programming Network 516 modes The Network 516 setting is selected through the heaters Installer parameters, in the same way other heater adjustments are made. Press the SET button on the NG-2A module to scroll through the displays. To make changes press the up/down buttons. To save changes press the SET button on the NG-2A module. Note: Refer to the Installers Menu in section 1.7 for the Net 516 setting on the NG2 Control board 279 Issue 1 - Service Manual Heater BX5 March

Service Manual. Brivis StarPro SP4, SP5 & SP6

Service Manual. Brivis StarPro SP4, SP5 & SP6 Service Manual Brivis StarPro SP4, SP5 & SP6 Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons not permitted

More information

Brivis Service Manual CC3 Gas Ducted Heater Compact Classic

Brivis Service Manual CC3 Gas Ducted Heater Compact Classic Brivis Service Manual CC3 Gas Ducted Heater Compact Classic Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons

More information

Brivis Service Manual BX3 Buffalo Gas Ducted Heater

Brivis Service Manual BX3 Buffalo Gas Ducted Heater Brivis Service Manual BX3 Buffalo Gas Ducted Heater Service shall be carried out only by Authorised Personnel. This Service Manual must NOT be left with the Owner, or distributed to other persons not permitted

More information

Brivis Service Manual

Brivis Service Manual Brivis Service Manual EMS (2) Energy M anagem ent Syst em Servicing shall be carried out only by A uthorised Personnel. T his Service Manual must N O T be left with the O wner. Service Manual 19 Heater

More information

Service Manual 4 Heater MPS & AUTO EMS Vol. 2 of 2 Approved Issue 10 Printed 13-Feb-14 11:52:53 AM 1

Service Manual 4 Heater MPS & AUTO EMS Vol. 2 of 2 Approved Issue 10 Printed 13-Feb-14 11:52:53 AM 1 Service Manual 4 Heater MPS & AUTO EMS Vol. 2 of 2 Approved Issue 10 Printed 13-Feb-14 11:52:53 AM 1 Index BULLETINS & SERVICING INSTRUCTIONS......... 4-19 MPS - Fit AFRO and New Style Burner.........

More information

Service Manual 3 Heater MPS & AUTO EMS Vol 1 of 2 Approved Issue 10 Printed 13/02/ :52:21 AM 1

Service Manual 3 Heater MPS & AUTO EMS Vol 1 of 2 Approved Issue 10 Printed 13/02/ :52:21 AM 1 Service Manual 3 Heater MPS & AUTO EMS Vol 1 of 2 Approved Issue 10 Printed 13/02/2014 11:52:21 AM 1 Index Pages INTRODUCTION:......... 4-5 THE N-G1/lo INSTALLATION & SET-UP INSTRUCTIONS:......... 6-8

More information

Service Manual - Heater - Electronic (TEK 300) Series - No.2 Issue 6 Printed 2/13/ :51:58 AM 1

Service Manual - Heater - Electronic (TEK 300) Series - No.2 Issue 6 Printed 2/13/ :51:58 AM 1 Service Manual - Heater - Electronic (TEK 300) Series - No.2 Issue 6 Printed 2/13/2014 11:51:58 AM 1 Index Page Technical Information Buffalo 3-6 Wombat 7-11 Upflow 12-14 Downflow 15-16 Airflow Chart 17

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This

More information

Brivis Service Manual

Brivis Service Manual ISO Documents Last modified by: Felicity Devine Date last modified: 23/02/2005 Document: Brivis Service Manual Evaporative Cooler Contour N-E3 & BC-E1 1999 Supplement This manual is to be used in conjunction

More information

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE

More information

Model Universal Oil Primary Control

Model Universal Oil Primary Control Model 70200 Universal Oil Primary Control Installation and Operating Instructions For Use By Qualified Service Technicians Only Universal Replacement for Carlin, Beckett, Honeywell and ICM Controls On-Board

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Rapid Response Series (RR e & RR i) OPERATING MANUAL

Rapid Response Series (RR e & RR i) OPERATING MANUAL Rapid Response Series (RR e & RR i) OPERATING MANUAL STADT INDUSTRIES PTY. LTD. MF-01 18/07/04 Operating Manual RR Series Stadt High Efficiency Central Heater. CONTENTS A): Introduction A: Introduction

More information

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating

More information

Service Guide. Service Guide NATIONAL COMFORT PRODUCTS GAS & ELECTRIC MODELS. 2nd Edition

Service Guide. Service Guide NATIONAL COMFORT PRODUCTS GAS & ELECTRIC MODELS. 2nd Edition 2nd Edition Service Guide Thru-the-Wall Packaged Heating & Cooling Units Service Guide GAS & ELECTRIC MODELS NATIONAL COMFORT PRODUCTS HEATING & A/C EQUIPMENT National Comfort Products A Division of National

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

Hot Surface Ignition (HSI) System Booklet

Hot Surface Ignition (HSI) System Booklet Hot Surface Ignition (HSI) System Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com 010298MFM/abe

More information

Model 60200FR Gas Primary Control Data Sheet

Model 60200FR Gas Primary Control Data Sheet Programmable, Microprocessor Based Gas Burner Primary Controls On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information Fault

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL Figure 1 Series 9 Intermittent Pilot Ignition Control Application The Series 9 Intermittent Pilot Ignition Control is a microprocessor

More information

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Horizon Natural Draft Electronic Ignition 3 Sided Gas Fireplaces Natural Draft Electronic Ignition

More information

Demand Duo Principle of Operation:

Demand Duo Principle of Operation: Page 1 of 25 8/23/2010 Contents: Demand Duo Principle of Operation:... 3 Schematic of Demand Duo:... 4 Demand Duo Fault Finding Check List:... 4 Basic operating principle of Demand Duo Thermostat:... 4

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION R SERIES 35-61 24 VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay F-35-61 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 21M51U-843 Universal Integrated Two-Stage 120Volt Hot Surface Ignition Control Kit INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS 50M56-743 Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD

More information

HEATING. Owner s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE. Bonus offer when you register your product online brivis.com.au.

HEATING. Owner s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE. Bonus offer when you register your product online brivis.com.au. HEATING Owner s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE Bonus offer when you register your product online brivis.com.au a company Index Introduction... 1 Privacy Notification Product

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler D E S I G N E D T O L E A D TWZ/CT/ODV Series Oil-Fired Hot Water Boilers (Less Tankless Heater) Installation Supplement for boilers equipped with honeywell L7248L 2012 Compliant boiler control These instructions

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 11/10/08 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev. 95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler Control Manual And Troubleshooting Guide P/N 24000604, Rev. C [04/09] WARNING! Revise boiler control parameters only if you fully understand the

More information

Brivis Inverter Icebox

Brivis Inverter Icebox Brivis Inverter Icebox R410A INSTALLATION INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING & USING THIS PRODUCT Bonus offer when you register your product online brivis.com.au Table

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0211 L3 Revised 09 2006 G60DFV(X) G60DFV(X) SERIES UNITS G60DFV series units are mid efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2004-28 TSG-SOLO-9/04 Table of Contents INTRODUCTION Page 1 SERVICING TIPS AND INSTRUCTIONS Page 3 CONTROL MODULE DISPLAY -

More information

59MN7A Series 100 TROUBLESHOOTING GUIDE

59MN7A Series 100 TROUBLESHOOTING GUIDE Variable Speed, Modulating Electronic Condensing Four-Way Multipoise Gas Furnace 59MN7A Series 100 TROUBLESHOOTING GUIDE INDEX PAGE Safety Considerations... 1 Instructions... 1 Example... 2 General...

More information

LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL

LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATER CONTROL PANEL HEATED AIR OUTLET Installation date: Installer: Installer phone No: Heater

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Technical Information Electric Slide-In Range JES9750BA* JES9860BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.

More information

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Thermo 230 / 231 / 300 / 301 / Troubleshooting Thermo 230 / 231 / 300 / 301 / 350 5 Troubleshooting 5 Troubleshooting 5.1 General This section describes troubleshooting procedures for the heaters Thermo 230, 231, 300, 301 and 350. CAUTION Troubleshooting

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

MG & SG SERIES BOILERS

MG & SG SERIES BOILERS S9361A CONTROL SUPPLEMENT MANUAL MG & SG SERIES BOILERS FOR MODELS MG-50-E TO MG-150-E AND SG-135-E TO SG-270-E NEW CONTROLLER This supplement manual must be used in conjunction with the Installation and

More information

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL SAFETY WARNING Please Refer to the Safety Warning in Section 7.1 regarding the chemicals in the oxygen sensor Analox Sensor Technology

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Technical Information Electric Slide-In Range JES8850BC* JES9900BC* JES9860BC* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair

More information

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions PBM1:12 2018-01-22 1 (36) Installation and maintenance instructions PBM1:12 2018-01-22 2 (36) TABLE OF CONTENTS 1 GENERAL INFORMATION... 5 1.1 PELLET STORAGE... 5 1.2 CONSTRUCTION AND FUNCTION... 6 1.2.1

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A66-743 Integrated Furnace Control Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL

More information

24 VAC Intermittent Pilot Gas Ignition Control

24 VAC Intermittent Pilot Gas Ignition Control C610U Universal 24 VAC Intermittent Pilot Gas Ignition Control Issue Date: 08/24/2016 Quick Reference Guide The C610U Universal Intermittent Pilot Gas Ignition Control module replaces many popular flame

More information

I/O ZONE 560/583 AND OPERATION MANUAL

I/O ZONE 560/583 AND OPERATION MANUAL UPM I I/O ZONE 560/583 INSTALLATION AND OPERATION MANUAL 1 UNIT PROTECTION MODULE HARDWARE OPERATION IMPORTANT: This manual is for UPM board part numbers 8733 800 259. See controller label as shown in

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Bosch 80% AFUE Gas Furnace BGS80 Model

Bosch 80% AFUE Gas Furnace BGS80 Model Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018

More information

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions PBM1:12 2008-10-16 1 (37) Installation and maintenance instructions PBM1:12 2008-10-16 2 (37) TABLE OF CONTENTS 1 GENERAL INFORMATION... 5 1.1 PELLET STORAGE... 6 1.2 CONSTRUCTION AND FUNCTION... 7 1.2.1

More information

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL Instruction Manual. SMARTELEC 2 SmartElec ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL 0 F1 INDEX Section General information ------------------------------------------------------------ 1 Dimensions

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

Control manual and troubleshooting guide

Control manual and troubleshooting guide Control manual and troubleshooting guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER! Revise boiler control parameters only if you fully understand the purpose and result of the changes.

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number Innovation In and Out of Parlour Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual Version - 1.0 Date - June 2016 Part Number - 39-0038 Index Manual Version... 3 About the Remote Vacuum

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

FURNACE OPERATION OVERVIEW

FURNACE OPERATION OVERVIEW You ve had a fun day but now it s getting chilly, so you decide to fire up the RV furnace. You flip the thermostat on, set the temperature and wait expectantly, but no heat comes from the outlets. It s

More information

Direct Vent Service Manual

Direct Vent Service Manual RHFE-551FA RHFE-1001FA RHFE-1001FA/VA RHFE-201FA RHFE-263FA, FAII RHFE-431FA, FAII, FAIII, WTA Direct Vent Service Manual RHFE-556FA, FAII, FAIII, FTRA, FTRAIII, WTA RHFE-1004FA ES08 ES11 ES17 EX17 ES22

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06) UPM I Unit Protection Module Installation and Operation Manual 6 720 220 321(2015/06) 2 Key to Symbols Contents Key To Symbols...2 Warnings...2 Specifications... 3 Unit Protection Module (UPM)....3 Power

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA) R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER

More information

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

Flame Safeguard Fault Code Diagnostics

Flame Safeguard Fault Code Diagnostics Vino s Vine Tech Tips Series 02/2013 Flame Safeguard Fault Code Diagnostics As manager of Tech Services, it probably comes as no surprise I spend some time discussing fault codes and corresponding corrective

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power. 27 Gas Dryer Technical Information MDG9700A * Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual

More information

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0124 L11 Revised 11 2006 G60UHV(X) G60UHV(X) SERIES UNITS G60UHV(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USERS GUIDE. LOGIC+ Combi 24, 30, 35 USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

MAINTENANCE AND SERVICE GUIDE

MAINTENANCE AND SERVICE GUIDE c Dimensions MAINTENANCE AND SERVICE GUIDE System II 80 and 100 Central Heating Fanned Flue Boiler Sizes in mm Flue types: C 12 or 42: horizontal C 32 xx: vertical concentric C 32 xy: Twin flue Boiler

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1 Lodam Compressor Protection Module Technical manual Version 3.0 SE-G1 Contents 1. Read this first... 4 1.1. Reading instructions... 4 1.2. User manual... 4 1.3. Safety... 4 2. General... 5 3. Definitions...

More information

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION 50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS INSTALLER MUST READ PAGE 3 CONTAINS WIRING HARNESS AND BLOWER CONNECTION INSTRUCTIONS FOR ALL APPLICATIONS

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

USERS GUIDE 24, 30. For installation guide see reverse of book

USERS GUIDE 24, 30. For installation guide see reverse of book USERS GUIDE 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

GB24 & GB30. User Manual

GB24 & GB30. User Manual GB24 & GB30 User Manual BOILER OUTPUT To Domestic Hot Water:To Central Heating: GB24/30 Minimum 8.0 kw (27,296 Btu/h) GB24 Maximum 24.2 kw (82,570 Btu/h) GB30 Maximum 30.3 kw (103,384 Btu/h) GB24/30 Minimum

More information

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35.. REPAIR INSTRUCTIONS TUMLE DRYER Vented WTA34.. / WTA35.. I. SAFETY INFORMATION Page 1 II. OPERATION Page 1 III. DESCRIPTION OF FUNCTION / TECHNICAL INFORMATION Page 2 IV. CONSUMPTION RATES / ENERGY REQUIREMENT

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC2 THRU NVC6 ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx WITH CONTROLINKS CONTROLS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas

More information

A/23 MFFI - A/27 MFFI

A/23 MFFI - A/27 MFFI A/23 MFFI - A/27 MFFI G.C.N. 47-6-0 / 47-6-2 Servicing Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of

More information

WC Series Vended Washers Troubleshooting, and Fault Codes

WC Series Vended Washers Troubleshooting, and Fault Codes WC Series Vended Washers Troubleshooting, and Codes 1 Common Troubleshooting s Symptom Probable Cause Suggested Remedy 2 Machine does not start Machine will not accept and count coins Door does not lock

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. 27 Domestic Dryer Technical Information MDE6700A*, MDG6700A* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer

More information

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS 21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE

More information

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove HEATING TECHNIQUE Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: +385 40 372 600, fax: +385 40 372 611 TECHNICAL INSTRUCTIONS for regulation, use and maintenance of pellet stove CentroPelet

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

SCHMIDT LED Measured Value Display MD Instructions for Use

SCHMIDT LED Measured Value Display MD Instructions for Use SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...

More information