SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90

Size: px
Start display at page:

Download "SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90"

Transcription

1 ENCASED THERMOSTATS Derived from the range of capillary control thermostats and limiters with liquid filled sensing element, they are the accurate, reliable and easily set-up devices for the regulation and the control of thermal systems. They are available in the following versions: contact, with probe, immersion, with perforated sheath. Contact control thermostat The thermostat is supplied completed with fasten spring for fixing it in position and with a mono-dose thermal paste bag (20g) (cod A - package of 100 bags of thermal paste). SENSOR liquid filled bimetallic internal protection A1-1R306-00A 7A1 7A1-6R306-00A A A 7A2 7A A C1-1R306-50A 7C C1-6R306-50A C A 7C C A Other temperature ranges and versions available on request. Contact limit thermostat The thermostat is supplied completed with fasten spring for fixing it in position and with a mono-dose thermal paste bag (20g) (cod A - package of 100 bags of thermal paste). liquid filled SENSOR bimetallic protection manual 9C2 9C A 65 manual 9C6 9C A 3

2 Capillary control thermostat GOLD BULB CAPILLARY reset PLATED DIMENSIONS internal CONTACTS IP 43 IP 55 7K1-6R326-00A 7K1-6S326-00A Ø 6,5 x K1-1R326-00A - 7K Ø 5 x 95 SS* - 7K1-1S326-01A automatic Ø 6,5 x K1-FR336-00A 7K1-FS336-00A Ø 5 x 95 SS* - 7K A K2 Ø 6,5 x 73-7K A * Stainless Steel version. Capillary limit thermostat GOLD BULB CAPILLARY reset PLATED DIMENSIONS internal CONTACTS IP 43 IP 55 Ø 6,5 x K6-9K A manual Ø 6,5 x K2-9K A special model - chimney limiter thermostat manual Ø 5 x K2-9K2-Q A 4

3 Immersion control thermostat for direct mounting internal reset P1-1R306-00A 7P1 7P1-6R306-00A automatic R 1/2 100 IP P A 7P2 7P A Immersion limit thermostat 9P6 9P A manual R 1/2 100 IP internal 9P2 9P A 5

4 Double immersion thermostat for direct mounting SPDT contacts: C/NO/NC (x2). T1 - CONTROL SET-POINT CALIBRATION T2 - control / LIMIT function internal control limiter 8P1-BR606-00A 8P P1-ER606-00A automatic 8P4-BR606-00A R 1/2 100 IP43 8P P4-ER606-00A 8P5-CR606-00A manual 8P P5-0R606-00A PROT. Double hot air thermostat with perforated sheath SPDT contacts: C/NO/NC (x2). T1 - CONTROL T2 - control / LIMIT function internal internal control limiter PROT automatic 8N2 8N2-B06B6-00A Ø 16 x 250 IP43 8N4 8N4-BR6B6-00A Other sheath length available on request. 8N1 8N1-BR6B6-00A manual 8N5 8N5-CR6B6-00A 6

5 Ambient thermostat in sealed container Provided with liquid filled sensing element and placed in IP55 housings, they are suitable for the temperature regulation of environments like greenhouses and livestock raising facilities. internal knob SENSING ELEMENT stainless steel spiral bulb 0 40 IP55 7R1 7R1-6R306-00A 7R1-5R306-00A R1-XR306-00A R B IP55 7R2 7R B 7

Frost Protection Thermostat

Frost Protection Thermostat 1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching

More information

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats Thermostats Type 343 Safety Temperature Monitor (STM) Type 344 Temperature Regulator (TR) Type 34 Safety Temperature Limiter (STL) Type 347 (TR/STL), Type 348 (TR/ST) and Type 349 (STM/STL) Double Thermostats

More information

Capillary & Bulb Thermostatic Control & Fail-Safe Limit

Capillary & Bulb Thermostatic Control & Fail-Safe Limit HCE + HDS HCE HLE Capillary & Bulb Thermostatic Control & Fail-Safe Limit Control & limit thermostats designed with flexible installation practice in mind, utilizing a rugged steel housing and covering

More information

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 1 202 Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 RAK-TW.1..H RAK-TW.1..H.. Use Function Changeover switch (S.P.D.T.) 2-position thermal reset limit thermostat with single-pole

More information

Boiler room components 0463EN October 2013

Boiler room components 0463EN October 2013 40 90 Boiler room components 0463EN October 2013 Contact regulation thermostat Electrical connections Terminal 1: common input Terminal 2: opens the circuit with the increase in temperature Terminal 3:

More information

Electric Air Heating Standard product ranges

Electric Air Heating Standard product ranges heating for a better future Electric Air Heating Standard product ranges For all your standard air heating applications Fin heaters page 2-5 Industrial convectors page 6-9 Duct heaters page 10-14 www.cetal.com

More information

Powers Controls ET 134 Low Temperature Detection Thermostat

Powers Controls ET 134 Low Temperature Detection Thermostat Document No. 155-115P25 ET 134-20 Powers Controls ET 134 Low Temperature Detection Thermostat Description Features Product Numbers The Electric Low Temperature Detection Thermostat is a remote bulb instrument

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V: 1½ or 2 RG IMMERSION HEATERS PAGE 1/5 Immersion heaters* are used to heat a variety of mediums, e.g. water, glycol, oil, and other liquids. It is important that the immersion heater is fitted to the side

More information

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW 1 212 Double thermostat Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW RAZ-TW... 2-position control thermostat and thermal reset limit thermostat with singlepole

More information

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits PSC966 European Refrigeration Controls Catalogue Catalog Section Product Bulletin A6 Series A6 - and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning Introduction

More information

Tubular Industrial Process

Tubular Industrial Process Alternate NEMA 1 Housing Type 3N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters Screw Plug Immersion Heaters TYPE 4N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters

More information

The T6140A,B Remote Bulb Temperature Controller

The T6140A,B Remote Bulb Temperature Controller T640A,B Remote Bulb Temperature Controller The T640A,B Remote Bulb Temperature Controller is used as a unit mount temperature controller in electric heat, fan coil, room air conditioner applications, cold

More information

THERMASREG TR 040 THERMASREG TR 060

THERMASREG TR 040 THERMASREG TR 060 THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary

More information

Mounting and Operating Instructions EB 2231 EN

Mounting and Operating Instructions EB 2231 EN Self-operated Regulators Thermostats Type 223 and Type 2232 Bulb Sensors Type 2233, Type 2234, and Type 2235 Air Sensors Type 223 with bulb sensor Type 2232 with bulb sensor (separate) Type 2233 with air

More information

"ER" Series Electric Humidifier

ER Series Electric Humidifier ER-1 Standard Water "ER" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain the

More information

Series A28 Two stage Thermostats. Feature and Benefits

Series A28 Two stage Thermostats. Feature and Benefits PSC9626 European Refrigeration Controls Catalogue Catalog Section 1 Product Bulletin A28 Series A28 Two stage Thermostats I ntroduction These thermostats are designed for various types of heating, cooling,

More information

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

More information

Flow Switch Replacement Parts

Flow Switch Replacement Parts Series FS4- General Purpose Liquid Flow Switches For Model All models (except those below) 045 FS4-5SS Stainless steel paddle kit 0. (.05) Series FS4-0500 FS4- SPDT switch 0. (.4) FS4-D 055 FS4-D-7 SPDT

More information

PORTABLE HEATERS MCS GROUP.

PORTABLE HEATERS MCS GROUP. PORTABLE HEATERS MCS GROUP www.mcsworld.com I CHOOSE MASTER PORTABLE HEATERS. WHY? SAVE MONEY heaters are plug and play: do not need installation USE THE SAME HEATER IN DIFFERENT PLACES heaters are portable

More information

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P 1 of 13 These instructions should be read by: The specifying engineer. The installation engineer. The user. The service engineer. WARNINGS Failure

More information

Thermostat KPU. Data sheet

Thermostat KPU. Data sheet Data sheet Thermostat KPU The KPU Thermostats are temperature controlled electrical switches, which are applied for regulation and safety monitoring of refrigeration and air conditioning systems. KPU sensors

More information

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS THERMAL INSTRUMENT Co. 217 Sterner Mill Road, Trevose, PA 19053 Telephone No. (215) 355-8400 Fax No. (215) 355-1789 Email: office@thermalinstrument.com INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES

More information

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY The heart of electric appliances MADE IN ITALY thermowatt.com 2 THERMOSTATS RTM 07 RTS 08 RTS PLUS 09 RTS ERP / RTS PLUS ERP 10 TES

More information

270XT Freeze Protection, IP30

270XT Freeze Protection, IP30 270XT Freeze Protection, IP30 Sensing element is 3 or 6 meters long to permit attaching across the surface of a coil to guard against freezing at any point. When any 30 cm or more of this element senses

More information

Wall-mounted air heaters for outdoor installation MEC EX C

Wall-mounted air heaters for outdoor installation MEC EX C all-mounted air heaters for outdoor installation for ducted outdoor installation wall-mounted air heaters have been specifically designed and certified for outdoor installation. he units are equipped with

More information

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08 16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)

More information

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual. Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual. The package of the 2R GT OF boiler contains instructions for installation, operation and

More information

PORTABLE HEATERS FOR PROFESSIONAL USE

PORTABLE HEATERS FOR PROFESSIONAL USE PORTABLE HEATERS FOR PROFESSIONAL USE www.mcs-heaters.com MASTER CLIMATE SOLUTIONS IS A WORLD LEADER IN THE PRODUCTION OF PORTABLE EQUIPMENTS FOR:, DEHUMIDIFICATION AND COOLING HEADQUARTERS MCS CLIMATE

More information

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostats type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical data... 3 Regulating ranges... 4 Ordering... 4 Contact systems...

More information

IT IT PRODUCT RANGE 2017 ANNI V IMIT CONTROL SYSTEM

IT IT PRODUCT RANGE 2017 ANNI V IMIT CONTROL SYSTEM IT IT IMIT CONTROL SYSTEM PRODUCT RANGE 17 ANNI V Our philosophy IMIT CONTROL SYSTEM has decided to accept the challenge: new products, top quality, immediateness of working process, with a careful and

More information

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80 Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical

More information

Vaccine Storage and Handling Training. Onondaga County Health Department November 2012

Vaccine Storage and Handling Training. Onondaga County Health Department November 2012 Vaccine Storage and Handling Training Onondaga County Health Department November 2012 Stocking Vaccine Refrigerators Stock should not touch the walls of the refrigerator. Allow space between walls and

More information

SUMMARY DOMESTIC ENVIRONMENTAL REGULATION

SUMMARY DOMESTIC ENVIRONMENTAL REGULATION PRODUCT RANGE 16 Our philosophy IMIT CONTROL SYSTEM has decided to accept the challenge: new products, top quality, immediateness of working process, with a careful and specific look at renewable energies.

More information

Accuracy by Design Products for the HVAC Professional

Accuracy by Design Products for the HVAC Professional Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation

More information

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION DIVISION SALES REFERENCE DATE 4 (Supersedes PG422-) DECEMBER, 2000 SECTION RAD PE440 6-058074-002 Screw Plug Heating Solution Control

More information

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE

More information

PORTABLE HEATERS FOR PROFESSIONAL use

PORTABLE HEATERS FOR PROFESSIONAL use PORTABLE HEATERS FOR PROFESSIONAL use www.mcs-heaters.com MASTER CLIMATE SOLuTIONS IS A WORLD LEADER IN THE PRODuCTION OF PORTABLE EQuIPMENTS FOR:, DEHuMIDIFICATION AND COOLING HEADQuARTERS MCS CLIMATE

More information

TEMPERATURE & PRESSURE CONTROLS

TEMPERATURE & PRESSURE CONTROLS TEMPERATURE & PRESSURE CONTROLS RANCO LUBE OIL PROTECTION CONTROLS These lube oil protection controls guard pressure-lubricated refrigeration compressors against major damage due to loss of oil pressure.

More information

temperature Controllers

temperature Controllers temperature Controllers Bulb and Capillary Thermostats Thermostat Styles and Selection Construction Characteristics This type of control operates by expansion and contraction of a liquid in response to

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:  Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable Process Auromation Edition 08.13

More information

TRV 300 RADIATOR VALVES

TRV 300 RADIATOR VALVES RADIATOR VALVES THERMOSTATIC HEADS Placed on radiator valves, these self-acting thermostatic heads for adjusting temperature are reliable, accurate, and long-lasting. LIQUID FILLED SENSOR ELEMENT For higher

More information

Thermostat RT. Data sheet

Thermostat RT. Data sheet Data sheet Thermostat RT RT thermostats incorporate a temperature controlled, single-pole change over switch where the contact position depends on the temperature of the sensor and the set scale value.

More information

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters Zip Tudor Installation Section & Operating Heading Instructions Single point open outlet (vented) water heaters Affix Model Number Label Here 81333 Above-Sink Tudor (No tapware included) Accessory Tapware

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for HUALING

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for HUALING GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for HUALING HUALING heating elements/thermostats heating elements heating elements for fryers 2 hole

More information

HUMIDISTATS and Electronic humidity controls

HUMIDISTATS and Electronic humidity controls 8 ULTIMHEAT HUMIDISTATS and Electronic humidity controls The professional solution: an extended, rational, and consistent range of products Technical catalogue for R&D department Edition 31/05/2013 E-Mail

More information

BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER

BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER EN (fi gure 1) BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER CONTROL PANEL The thermostat box to control the appliance is

More information

ELECTRIC CONVECTOR HEATER. This product is only suitable for well insulated spaces or occasional use.

ELECTRIC CONVECTOR HEATER. This product is only suitable for well insulated spaces or occasional use. EN ELECTRIC CONVECTOR HEATER IP24 This product is only suitable for well insulated spaces or occasional use. OPERATING INSTRUCTIONS Read the instructions carefully before installing and operating the appliance

More information

Thermometers with capillary tube. Bimetal thermometers. Industrial thermometers. Resistance thermometers

Thermometers with capillary tube. Bimetal thermometers. Industrial thermometers. Resistance thermometers Thermometers with capillary tube Bimetal thermometers Industrial thermometers Resistance thermometers CHAPTER Temperature measuring instruments and controllers OVERVIEW Mechanical temperature measuring

More information

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution

More information

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES) BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL (1.500-5.000 LITRES) VETRIFICATO GLASSLINED BF1 1500-2000 - 3000-5000 KEYWORD 1: Primary fluid inlet (heating side); 2: Primary fluid outlet (heating

More information

Finned Tube Air Heaters Type WD/GG (RVS)

Finned Tube Air Heaters Type WD/GG (RVS) Finned Tube Air Heaters Type WD/GG (RVS) Our WD-H finned-tube heaters are designed for industrial use in drying rooms, engine rooms, pumping houses, elevator shafts, as protection from frost, etc. The

More information

Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER

Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER Heat energy can be transferred from a place where it is very hot to a place where it is not

More information

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit FSW Product guide E SECTION Thermostats, Pressure Switches & Fan Speed Controls. 63 64 Head Office 01543 437 010 Danfoss Service Thermostat Kits TYPE TO SUIT E005 NO-1 Refrigerator E006 NO-2 Refrigerator

More information

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System HEATING System fan (from model 25) and a MBE electric heater installed on the discharge side of the fan. + MBE ELECTRIC HEATER MBE heater type - Insulated element rods. - Automatic overheat thermostat

More information

CIMSA-FABAR. Warewashing equipment. Spare parts for: Suitable for:

CIMSA-FABAR. Warewashing equipment. Spare parts for: Suitable for: Spare parts for: Warewashing equipment This catalogue is automatically generated. Therefore, the sequence of the items might not be always shown at best. Updates will be issued in case of additions and/or

More information

Hygrostats (hygrometric)

Hygrostats (hygrometric) Data Sheet 907032 Page 1/6 Hygrostats (hygrometric) For easy 2-state control of relative air humidity For indoor and air duct mounting With potential-free change-over contact(s) No voltage supply required

More information

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m Technical data and code nos. When ordering, please state type and code number. Thermostats with cylindrical remote sensor Adjustable differential range*) Types of charge A: Vapour charge - sensor must

More information

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing

More information

TERMOREGOLAZIONE THERMAL REGULATION

TERMOREGOLAZIONE THERMAL REGULATION Termoregolazione /Thermal regulation Termoregolazione /Thermal regulation 31 TERMOREGOLAZIONE THERMAL REGULATION Termostati, Guaine, Regolatori tiraggio, Valvole di zona, Motori Thermostats, Sheaths, Draught

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for FRIFRI

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for FRIFRI GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for FRIFRI FRIFRI heating elements heating elements heating elements for chip scuttles No. 48465 Ref.

More information

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion

More information

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT. Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version

More information

Frost Units for air temperature monitoring

Frost Units for air temperature monitoring 284 284P0 Frost Units for air temperature monitoring QAF8... Robust aluminium die-cast housing Responds to temperature change sensed over any 30 cm length of capillary Small switching differential Good

More information

Environmental Chambers

Environmental Chambers Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm

More information

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK This booklet will assist you in piping, wiring and setting the controls of the Riva Advance SV boiler to control an indirect fired hot water tank. All pipe tails for the connection to the tank are supplied

More information

JDDT1 - Single Stage Digital Thermostat

JDDT1 - Single Stage Digital Thermostat JDDT1 - Single Stage Digital Thermostat CAUTION NOTICE: The thermostat must be installed by authorized professionals. It should be located in a place free of vibrations, impacts, and corrosive gases. SET

More information

Gas-fired unit heaters for indoor installation

Gas-fired unit heaters for indoor installation UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat

More information

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B

More information

A19, A28 Series Thermostats for Agricultural Buildings

A19, A28 Series Thermostats for Agricultural Buildings A19, A28 Series Thermostats for Agricultural Buildings FANs 121, 125 Temperature Controls Section A Product Bulletin A19, A28 Issue Date 1088 Application These thermostats are designed for heating and

More information

Dual Pressure Controls

Dual Pressure Controls PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393

More information

2 Gallon Water Boiler

2 Gallon Water Boiler USER S GUIDE 2 Gallon Water Boiler READ AND SAVE THESE INSTRUCTIONS NOTICE TO INSTALLER: Please leave this booklet with the machine. CONTENTS CL39...FS39... IS2...II20...II21...CI16............ES83.........

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

PRODUCT RANGE IMIT CONTROL SYSTEM

PRODUCT RANGE IMIT CONTROL SYSTEM PRODUCT RANGE 15 10 IMIT CONTROL SYSTEM IMIT: leader in thermoregulation for over a hundred years. History Since 1917, at IMIT we have always discussed solutions. We began with electromechanics, becoming

More information

THIRODE. Ovens. Spare parts for: Suitable for:

THIRODE. Ovens. Spare parts for: Suitable for: Spare parts for: Ovens This catalogue is automatically generated. Therefore, the sequence of the items might not be always shown at best. Updates will be issued in case of additions and/or amendments.

More information

Powers Controls Low Temperature Detection Thermostat

Powers Controls Low Temperature Detection Thermostat Document No. 155-016P25 ET 134-22 Rev. 1, February, 2000 Powers Controls Low Temperature Detection Thermostat Description The electric Low Temperature Detection Cut-out and Alarm Thermostat is a remote

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications UNIT OBJECTIVES After studying this unit, the reader should be able to Discuss space temperature control. Describe

More information

Tubular Industrial Process

Tubular Industrial Process Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

E1808, E1838, E1848 DEEP FAT FRYER INSTALLATION, SERVICING and USER INSTRUCTIONS

E1808, E1838, E1848 DEEP FAT FRYER INSTALLATION, SERVICING and USER INSTRUCTIONS E1808, E1838, E1848 DEEP FAT FRYER INSTALLATION, SERVICING and USER INSTRUCTIONS IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and

More information

MKN. Cooking equipment. Spare parts for: Suitable for:

MKN. Cooking equipment. Spare parts for: Suitable for: Spare parts for: Cooking equipment This catalogue is automatically generated. Therefore, the sequence of the items might not be always shown at best. Updates will be issued in case of additions and/or

More information

QZHW Fan Coil Unit. Key features. Specifications

QZHW Fan Coil Unit. Key features. Specifications Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different

More information

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS CONTENTS 1. Transportation Positioning Installation 3 2. Starting up 3 3. Safety instructions 4 4. Temperature regulation

More information

Air/water - Heat pumps

Air/water - Heat pumps Air/water - Heat pumps Installation of a NIBE air/water heat pump can lead to your energy consumption for heating being reduced by up to 50%, in comparison to conventional heating systems. Areas of Use

More information

Tubular Industrial Process

Tubular Industrial Process consist of tubular elements welded or brazed into a threaded screw plug which can then be inserted into a threaded opening in a tank wall or through a mating full or half coupling. Standard Screw Plug

More information

Maximum rated temperature Maximum ambient temperature

Maximum rated temperature Maximum ambient temperature 901A Heat conducts through the metal mounting plate to trigger the thermostat. Provide good and stable thermo- control and minimum EMC interference. Has been widely applied in kitchen cooking products

More information

HEATING BLANKETS BFVIBC

HEATING BLANKETS BFVIBC HEATING BLANKETS BFVIBC Electric heating system for IBC tote tanks of 1.000 L (275 gal) Heating cables Flexible electrical resistors Heating bases Heating modules Crankcase heaters Heating blankets Heating

More information

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:

More information

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction

More information

OPERATING AND MAINTENANCE MANUAL FOR PACKAGED ELECTRIC TEPID WATER HEATING SYSTEMS BASE MODEL ESS

OPERATING AND MAINTENANCE MANUAL FOR PACKAGED ELECTRIC TEPID WATER HEATING SYSTEMS BASE MODEL ESS OPERATING AND MAINTENANCE MANUAL FOR PACKAGED ELECTRIC TEPID WATER HEATING SYSTEMS BASE MODEL ESS THERM-OMEGA-TECH, INC. 353 IVYLAND RD, WARMINSTER, PA 18974 PHONE: (877) 379-8258 INTERNET: http://www.thermomegatech.com

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for GRANDIMPIANTI

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for GRANDIMPIANTI GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for GRANDIMPIANTI GRANDIMPIANTI heating elements/thermostats heating elements heater battery No. 4522

More information

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater Products Company Markel Products Company Markel Products Company Markel Products Co HLA Series Hazardous Location Fan Forced Unit Heater FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C &

More information

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater HLA Series Hazardous Location Fan Forced Unit Heater FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C & D, DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2. Shown with optional

More information

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for LA CIMBALI LA CIMBALI heating elements heating elements heating elements for coffee machine No.

More information

AIREX 2S WOOD PYROLYSIS SUCKING FAN

AIREX 2S WOOD PYROLYSIS SUCKING FAN AIREX S WOOD PYROLYSIS SUCKING FAN To optimize green energy AIREX S constitutes the evolution of the firewood boilers range: total gasification inverted flame with sucking fan especially suitable to the

More information

Explosion-proof Immersion Heater Type D-8660

Explosion-proof Immersion Heater Type D-8660 Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to

More information

Thermostats ICE MAKERS. Spare parts for:

Thermostats ICE MAKERS. Spare parts for: Spare parts for: ICE MAKERS This catalogue is automatically generated. Therefore, the sequence of the items might not be always shown at best. Updates will be issued in case of additions and/or amendments.

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Tower & Obstruction Lighting

Tower & Obstruction Lighting Tower & Obstruction Lighting Selection Guide... 10.2 Beacon Flasher FA... 10.4 FS155-... 10.4 FS165-... 10.4 Lamp Monitors Incandescent Lamps FB... 10.6 SCR490D... 10.7 SCR430T... 10.8 SCR630T... 10.8

More information