Product Information Packet

Size: px
Start display at page:

Download "Product Information Packet"

Transcription

1 Product Information Packet Model FHP-750 Nema-12 FlushMount Air Conditioner withtc-6f Temperature Control Part #7-A Thank you for your purchase. Information has been enclosed regarding the installation, specifications,and wiring ofyour solid-state assembly. Please read and follow all instructions carefully beforeinstallation. Only qualified technicians should install this equipment. If you have any questions regarding your equipment,please do not hesitate to call us at , and we will be happy to assist you. We are open from 8:00 am-4:30 pm Central Time. Included in this packet you will find: Installation Notes for Air Conditioners Product Literature and Specifications Wiring Drawing #SK Installation Drawing # Temperature Control Information Warranty Information

2 Important InstallationNotes forair Conditioners Mounting Styles: Both thru mount and flushmount unitscan bepositioned in anyorientationand on any enclosure surface. Itis important toconsider interior airflowpatterns whendeterminingthe mountinglocation. Alsoof importance isan unrestricted flowof ambient air thruthe hotside heat exchanger. Ease of access andinspection must be considered forthoseapplications in particularly severe environments which may require occasional maintenance. Vertical (Side/Front/Back) Mounting: Verticalmounting refers to the vertical direction of the cold side or interior finsand isrecommendedfor applications withhigh humidity, poorand incomplete cabinet seals or any condition which may cause thecold side finsto bemaintained attemperatures below the dewpoint for longperiods of time allowing for the formation of condensation. The vertical fin direction provides adrip path whereupon condensation canbe collected via amoisture removal system(standard on FHP-units)or adrip pan positioned below the coldside fins. Drip pansare optional for thrumount units. Ambient Air Path Enclosure InternalAir Path Seal CondensateRemoval System: All FHP-SeriesandAHP-1400 air conditioners contain abuilt-in condensateremoval system. The condensatekit consists of a antifungal sponge with acondensate wick. PVCtubingis alsoprovided for drainage. Drippansare optional for thrumountunits which must beevaluated onan individualbasis. Equations defining arelationshipbetween the cold side fin and enclosure temperatures are provided to assist in theevaluation. Top Mounting: Thoughoften the easiest location tomount it is often the mostdifficult to protect from condensation inthisorientation due to the fin orientation,gravityand anysusceptiblecomponentsbelow. If adrip panisemployed by the end userusecautionto place the panfar enough awayfrom the internal fan tominimize therestriction ofairflow.the pan should coverthefin ends as well as the fanarea. When there isachoice, thevertical orientation ispreferred bymost users. Maintenance: Since the technologyis solid-state,there are nofilters,compressors,orfluorocarbons tomaintain. The only movingpartsare the fans. It isrecommended forharsh or dirtyenvironmentsthat the heatsinks be cleaned from timeto time. Thiscan be accomplishedbydirecting compressed air over the external fins or on NEMA4versions byhosing theunit down. This will increasethe overall life andperformanceof the system. Cautions: Take care when mounting not to damagethe seal between thehot and coldside sinks. Do not attempt to mount aunit to a warpedsurfaceor tryto make the units mountingsurface conformtoan unflat surface. Do not pinch ordamage anyleadswhen mounting. Donot over tighten anyinstallation screw, use reasonableforce. Alwaysmount withany condensate drain down. Do notcompress thecold side between the hot side and any other surface. Do not obstruct theairflowon either side. When mounting consider the natural air flows ofthe enclosure. Connect power onlyafterthe installation is complete. Notes on condensation: Condensationoccursat thecold side finswhenthe surface temperature goes below the dew point. Toreduceorremove condensate, considerthe following: Regulate thefintemperature above thedewpoint. Keep Enclosure Closed and Sealed fromoutside Humidity. Use Desiccant (Moisture absorbing Granules.) Employ CondensateRemoval System/Drip Pans. Ifyou have anyquestions regarding yourinstallation, Please feel freeto contact our technical department forassistance at

3 FHP-750 Air Cooled Flush Mounted NEMA-12, NEMA-4 Air Conditioner 120 VAC, 240 VAC Input FEATURES Externally mounted, no intrusion Compact (only 12 L X 6 W X 9 D) Weighs only 16 lbs. (7.2 kg) Ambient range -10ºC to +70ºC No compressor, fluorocarbons or filters Virtually maintenance-free operation Stainless steel exterior housing NEMA-4 and NEMA-12 versions Both 120 VAC and 240 VAC available Mounts and operates in any orientation (condensate removal system may not work properly in all orientations) INCLUDES Integral power supply Power input cable Condensate removal system Adjustable temperature control Gasket for mounting Mounting hardware OPTIONS Other temperature settings for single set point controls Custom finishes N E M A 12 N E M A 4 SPECIFICATIONS OPERATING OPERATING PERFORMANCE VOLTAGE CURRENT WEIGHT TEMP. AMBIENT ENCLOSURE AGENCY MODEL PART NUMBER NOTES RATING VAC AMPS. LBS. (KG) CONTROL TEMPERATURE TEMPERATURE APPROVALS BTU/HR 50/60 HZ RANGE C RANGE C FHP A Cool only (7.2) TC-6F -15/+65-10/+60 UL1995, CSA22.2 FHP A Cool only (7.2) EXT* -15/+65-10/+60 UL1995, CSA22.2 FHP A5F Cool only (7.2) 85 F (30 C) -15/+65-10/+60 UL1995, CSA22.2 FHP A Cool only (10.5) TC-6F -15/+65-10/+60 UL1995, CSA22.2 FHP A Cool only (10.5) EXT* -15/+65-10/+60 UL1995, CSA22.2 FHP A5F Cool only (10.5) 85 F (30 C) -15/+65-10/+60 UL1995, CSA22.2 FHP-750XE 7-A Cool only (8.6) TC-6F -40/+65-10/+60 UL1995, CSA22.2 FHP-750XE 7-A Cool only (8.6) EXT* -40/+65-10/+60 UL1995, CSA22.2 FHP-750XE 7-A5F Cool only (8.6) 85 F (30 C) -40/+65-10/+60 UL1995, CSA22.2 FHP-752XE 7-A Cool only (11.5) TC-6F -40/+65-10/+60 UL1995, CSA22.2 FHP-752XE 7-A Cool only (11.5) EXT* -40/+65-10/+60 UL1995, CSA22.2 FHP-752XE 7-A5F Cool only (11.5) 85 F (30 C) -40/+65-10/+60 UL1995, CSA22.2 * Unit is set for 5-32 VDC external signal, relay(s) included 60 TECA TECA-USA ( )

4 PERFORMANCE CURVE Air Conditioner - Air Cooled FHP-750 MOUNTING STYLE Flush Mounted ENVIRONMENTS SERVED NEMA-12 IP 52 NEMA-4 IP 56 RATING (TRADITIONAL) F T F T RATING (DIN 3168) 125 Watts L35 L35 * 78 Watts L35 L50 See page 10 * Equation of line: y= T( C) x=capacity (Watts) Ambient Temp 20 C 40 C 60 C Enclosure Air y=.29x-34.5 y=.29x-36.5 y=.29x-38.5 Cold Sink y=.18x-34.5 y=.18x-36.5 y=.18x-38.5 Air Flow Pattern DIMENSIONS TECA-USA ( ) TECA 61

5

6

7

8 DECLARATION OF CONFORMITY TYPE OF EQUIPMENT Electrical Heat Pump, Air Conditioner Solid State Cooling Devices MODEL NUMBERS Model nos. AHP-1200, AHP-1201, AHP-1202 followed by FF, XE, X; may be followed by HC may be followed by W/TC followed by -3F or -6F or Remote TC. Model nos. AHP-1800, AHP-1801, AHP-1802 followed by FF, XE, X; may be followed by HC may be followed by W/TC followed by -3F or -6F or Remote TC. Model nos. FHP-750, FHP-752 may be followed by XE; may be followed by W/TC followed by TC-6F or Remote TC. Model nos. AHP-1501, FHP-1501 may be followed by XE; may be followed by HC may be followed by W/TC followed by -6F -3F or Remote TC. YEAR OF MANUFACTURE Refer to the first two digits of the serial number on the manufacturers ID label MANUFACTURER TECA Corporation 4048 W. Schubert Avenue Chicago, IL U.S.A. APPLIED STANDARDS Standard for Safety of Heating and Cooling Equipment (UL 1995 / CSA C No rd Edition, dated: February 18, 2005) Safety of household & similar electrical appliances EN Part 1: General requirements Safety of household & similar electrical appliances EN Part 2: Particular requirements for electrical heat pumps, airconditioners & dehumidifiers (IEC : 1992, Modified) TESTING AGENCY TÜV Rheiland ITS Intertek Testing Services ETL SEMKO REPORT No. TÜV Report Number: USA-TJ ; USA-TJ ETL Report Number: CHI-001; CHI-001; CHI-001 VP of Engineering Andy Brecklin August 10, 2011

9 LIMITEDWARRANTY In theevent adefect in material or workmanship isdiscovered in any of TECA s products withinone year after the date theyare delivered tobuyer, and if:(a)tecaisnotifiedofthe defect inwriting by certified mail within 14 daysof the date ofdiscovery; (b)tecamay theneither,atits sole discretion, inspect the productatbuyer s location, or requirethatthe product be made available at Buyer sexpense atteca s premisesfor TECA sinspection within 14 days ofthe date of notification; and (c)theproductsare defective and the defects resultfromfaulty materials and/orworkmanship and not in any way fromaccident, misuse,misapplication, mishandling, modification,oralteration by the Buyeror the shipper, then TECAshall,at its sole option, repair or exchange defectiveproducts free of charge tobuyer,or credit tobuyer the price of the defective products. ALLOTHER WARRANTIES,EXPRESS OR IMPLIED,ARE EXCLUDED, INCLUDINGBUTNOT LIMITEDTOTHE IMPLIEDWARRANTIES OFMERCHANTABILITYANDFITNESS FORA PARTICULARPURPOSE. IN NO EVENTSHALLTECABE LIABLEFOR ANYCLAIM BASED UPONBREACHOFEXPRESS OR IMPLIED WARRANTY ORANYOTHER DAMAGES WHETHERSPECIAL, INDIRECT, INCIDENTAL,CONSEQUENTIAL, LOSTPROFITS, BUSINESS INTERRUPTION,OR LOSSOFBUSINESS OR CUSTOMER RELATIONSHIPS. RETURNED GOODS,RESTOCKINGCHARGES In order to return merchandise for anyreason (repair,replacement, or credit) areturn authorization number mustbe issued byteca. New merchandise maynotbe returned for credit beyond 60daysfromshipment. Chargesfor incidental or other damagesmay also be made. All returnedgoods mustbe sentfreight prepaid. Arestocking charge of 15% will apply. On special equipment andcustommodified equipment orders, additional incremental cancellation charges may be made.

Product Information Packet

Product Information Packet Product Information Packet Model AHP-6200 Series Solid State, Air Conditioner Thank you for your purchase. Information has been enclosed regarding the installation, specifications, and wiring of your solid-state

More information

Product Information Packet

Product Information Packet Product Information Packet Model AHP-2250XEHC Solid State, NEMA 4, Air Conditioner High Capacity With TC-7F Temperature Control Part #0-H5I0-5-000 Thank you for your purchase. Information has been enclosed

More information

Product Information Packet

Product Information Packet Product Information Packet Model LHP-1702FF Solid State Liquid Cooled Air Conditioner Without Temperature Control Part #2-1092-0-000 Thank you for your purchase. Information has been enclosed regarding

More information

Product Information Packet

Product Information Packet Product Information Packet Model AHP-1800XPHC Solid State, NEMA 4X, Class IDiv 2, Heat/Cool Air Conditioner with TC-3F Temperature Control Part #0-0130-3-003 Thank you for your purchase. Information has

More information

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP Cooling Solutions for Mission- Critical Electronics This manual

More information

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions

More information

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 500 Btu MODEL # S AAC-142-4XT AAC-142-4XT-HC AAC-142-4XT-XXXXX Cooling Solutions for Mission-Critical Electronics

More information

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 1500 Btu MODEL # S AAC-145-T-E AAC-145-4XT-E AAC-145-T-E-HC AAC-145-4XT-E-HC AAC-145-XXXXX Cooling Solutions for

More information

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components hermoelectric technology is easy to overlook due to upfront cost or power requirements. Once educated about and committed to the technology, however, thermoelectric cooling can be the best choice for harsh

More information

SEALED ENCLOSURE COOLING

SEALED ENCLOSURE COOLING ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts www.1-act.com SEALED ENCLOSURE COOLING ABOVE-AMBIENT AND SUB-AMBIENT COOLING PRODUCTS TABLE OF CONTENTS HEAT SINK COOLER (ACT-HSC) HEAT EXCHANGER

More information

Cooling Solutions for Mission-Critical Electronics

Cooling Solutions for Mission-Critical Electronics Thermoelectric Air conditioner installation and operation manual FOR 3200 Btu MODEL # S AAC-161-4XT AAC-161-4XT-HC AAC-161-XXXXX Cooling Solutions for Mission-Critical Electronics TABLE OF CONTENTS 1.

More information

Quality Enclosures and cooling solutions for every environment

Quality Enclosures and cooling solutions for every environment Thermoelectric Air conditioner installation and operation manual FOR 400 Btu MODEL # S AAC-140-T AAC-140-4XT AAC-140-T-HC AAC-140-4XT-HC AAC-140-XXXX Quality Enclosures and cooling solutions for every

More information

A TEMPERATURE CONTROLLER

A TEMPERATURE CONTROLLER A TEMPERATURE CONTROLLER BREAKTHROUGH! Borg-Warner Thermoelectrics, the experts in solid state cooling, proudly introduces the new RTC-111 Robotic Temperature Controller, with voice announcement capabi

More information

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc. Installation Manual 000 Version.0 EXP-000 HBX Control s Inc. Control s Inc. HBX EXP 000 Version.0 HBX EXP-000 EXPANSION MODULE INTRODUCTION The EXP-000 is designed to be integrated with the HBX CPU-000

More information

Blade Series Heat Exchanger Operation and Installation

Blade Series Heat Exchanger Operation and Installation Blade Series Heat Exchanger Operation and Installation *IMPORTANT* For safe and satisfactory operation, please read the following instructions. Keep these instructions for future reference. Some information

More information

Product Specifications Linear Accelerator Relay Junction Box

Product Specifications Linear Accelerator Relay Junction Box NOVA Energy & Automation Product Specifications Linear Accelerator Relay Junction Box Model NEAVRJB-C3 03 January 2012 Product Description 1. Standard Applications The Nova NEAVRJB-C3 relay junction box

More information

Desiccant / Pump Dehumidification System. Model Operating Manual

Desiccant / Pump Dehumidification System. Model Operating Manual Desiccant / Pump Dehumidification System Model 5471 Operating Manual 6/30/06 www.electrotechsystems.com TABLE OF CONTENTS Model 5471 Desiccant / Pump Dehumidification System PARAGRAPH DESCRIPTION PAGE

More information

ELP21LU3-LF-HLOL THREE CHANNEL

ELP21LU3-LF-HLOL THREE CHANNEL ELP21LU3-LF-HLOL THREE CHANNEL 516-467-5787 HI LEVEL LOW LEVEL LEAK DETECTION 11.00 TEST SYSTEM DETECTING HORN OFF 6.00 SPECIFICATIONS POWER INPUT 85-125 VAC, 47-440 Hz 16 Watts maximum POWER TO SENSORS

More information

V LPM Desiccant Air Dryer Installation and Operation Manual

V LPM Desiccant Air Dryer Installation and Operation Manual 451 Black Forest Road Hull, IA 51239 Ph: (712) 439-6880 Fax: (712) 439-6733 www.ozonesolutions.com V-20 20 LPM Desiccant Air Dryer Installation and Operation Manual V-20 Manual Table of Contents Cautions,

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS Utility Coolers MODEL NOS. US4KP US10KP IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint

More information

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N T-SERIES Air Conditioner T62 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-239 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING THE AIR CONDITIONER... 3 INSTALLATION INSTRUCTIONS...

More information

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity

More information

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3 SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3 READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE READ AND SAVE THESE INSTRUCTIONS: DO NOT CONNECT POWER

More information

Superdryer Dehumidifiers

Superdryer Dehumidifiers Superdryer Dehumidifiers Installation and Operations Manual Read and Save These Instructions Distributed Exclusively By: Air Cleaning Equipment, Inc. Broadway, NC 27505 Phone: 919-258-3330 www.aircleaningequipment.com

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model 18 Product Overview : Makes electronics cooling easier, so you can go about your business SPECTRACOOL

More information

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3

More information

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.

More information

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE READ AND SAVE THESE INSTRUCTIONS: DO NOT CONNECT POWER

More information

Proliphix Thermostat Installation Guide. Release 2.0

Proliphix Thermostat Installation Guide. Release 2.0 Proliphix Thermostat Installation Guide Release 2.0 July 2006 Beta Draft Confidential Technical Support When contacting Proliphix for technical assistance, please have the following information available:

More information

Outdoor Enclosure Manual

Outdoor Enclosure Manual Outdoor Enclosure Manual Mini-Fort Outdoor Equipment Enclosure August 7, 2013 Rev IR Table of Contents Release to this Technical Documentation...3 Using this Instruction Manual & Inspecting Shipment...4

More information

SEALED ENCLOSURE COOLING

SEALED ENCLOSURE COOLING ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts www.1-act.com SEALED ENCLOSURE COOLING HSC -22 HSC -45 HSC -68 C UL US LISTED SA44609 ACT-HSC HEAT PIPE COOLERS: INSTALLATION GUIDE OPERATION

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Model PT-05 Model PT-06

Model PT-05 Model PT-06 Model PT-05 Model PT-06 operators handbook Preface Dear User Welcome to the growing group of PT-06 Clam-Press and PT-05 Clam- Press Mini users. The product you have purchased has been carefully designed

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62 electric fireplaces INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62 INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL

More information

Product Specifications 480 VAC, 175A Main Power Distribution Panel

Product Specifications 480 VAC, 175A Main Power Distribution Panel NOVA Energy & Automation Product Specifications 480 VAC, 175A Main Power Distribution Panel Model NEAS-43175-ST 29 July 2012 Product Description 1. Standard Applications The Nova NEAS-43175-ST system Main

More information

Product Specifications Auto Restart Main Power Distribution Panel

Product Specifications Auto Restart Main Power Distribution Panel NOVA Energy & Automation Product Specifications Auto Restart Main Power Distribution Panel Model NEA090AR/RTX 03 January 2012 Product Description 1. Standard Application The Nova Auto Restart system Main

More information

MODEL 891 FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: SHIPPING DIMENSIONS: - 19"W 19"D 28"H SHIPPING WEIGHT: - 46 LBS.

MODEL 891 FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: SHIPPING DIMENSIONS: - 19W 19D 28H SHIPPING WEIGHT: - 46 LBS. FOOD WARMING/ MERCHANDISING CABINET MODEL 891 With illuminating LED lights and simple Digital Temperature Controller, keeping your products on the shelf will no longer be a challenge. Circulating, heated

More information

USER GUIDE & INSTALLATION INSTRUCTIONS

USER GUIDE & INSTALLATION INSTRUCTIONS HARVESTEDGE TM THE NEW STANDARD IN LINEAR LED TOPLIGHT USER GUIDE & INSTALLATION INSTRUCTIONS Designed & Manufactured in Austin, TX illumitex.com 888.657.3520 THE DIGITAL HORTICULTURE COMPANY ref EDG.INST.9.2018.v2

More information

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217) ! BUNN DISCONNECT FROM POWER SOURCE BEFORE REMOVAL OF ANY PANEL OR REPLACEMENT OF ANY COMPONENT! WARNING H5E H5M H5X WARNING Very Hot Water Use With Care!! ILLUSTRATED PARTS CATALOG Designs, materials,

More information

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series DESCRIPTION The SZL-VL-S Series miniature-type limit switch is designed for use in applications where limited space is available. With IP67

More information

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ Enclosure Only Enclosure with 110 VAC Heater Option Enclosure with 240 VAC Heater Option Features Hazardous Classification Class II Groups F&G Div. 2 and

More information

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS SAFETY ALERT SYMBOLS Read and follow all safety information carefully. The signal words used in this manual are selected as shown below and based on an assessment of the degree of potential injury or damage

More information

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes Spec-75 A( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Compact Indoor N17 115/23 Volt 1 BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527

More information

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions Quest Dry 150 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide SA44609 ACT-HSC-22 ACT-HSC-45 ACT-HSC-68 Sealed Enclosure Coolers Keep The Inside of your Enclosure Free of Dirt & Debris NEMA

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners PH FX ( Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model G28 Indoor Model 18 18 Product Overview : Makes electronics cooling easier, so you can go about

More information

USER MANUAL SAVE THESE INSTRUCTIONS

USER MANUAL SAVE THESE INSTRUCTIONS USER MANUAL Model: PM50 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067

More information

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions Quest Dry Quest 110 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S NIR-50-325 RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 8 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

5) Do not start or stop the unit by inserting or pulling out the power plug.

5) Do not start or stop the unit by inserting or pulling out the power plug. 3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance

More information

VSA Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud

More information

Electric Duct Heaters

Electric Duct Heaters Electric Duct Heaters 12541_Tutco_Catalog.indd 1 3/4/11 8:46:01 AM TYPICAL HEATER CONSTRUCTION TUTCO, the world s largest supplier of open coil heating elements, produces the highest quality products in

More information

Product Specifications 480 VAC, 70A Main Power Distribution Panel

Product Specifications 480 VAC, 70A Main Power Distribution Panel NOVA Energy & Automation Product Specifications 480 VAC, 70A Main Power Distribution Panel Model NEAS-43070-ST 29 July 2012 Product Description 1. Standard Applications The Nova NEAS-43070-ST system Main

More information

Model 1850F Dehumidifier Installation and Operating Manual

Model 1850F Dehumidifier Installation and Operating Manual Model 1850F Dehumidifier Installation and Operating Manual ON/OFF button used to turn dehumidifier on and off Up/Down buttons used to change humidity setting Dehumidifer Control Outlet MODE button used

More information

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO MICRO SWITCH Key Actuated Safety Switches GKN Series 004740 Issue 3 Datasheet FEATURES Red switch body for easy safety recognition Four different styles of stainless steel actuator keys Three conduits

More information

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus MICRO GROW GREENHOUSE SYSTEMS, INC 42065 ZEVO DR., SUITE B-1, TEMECULA, CA 92590 PHONE (951)-296-3340 FAX (951)-296-3350 Growmate Growmate Plus INSTALLATION PROCEDURES GROWMASTER AND GROWMATE SERIES OF

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

Installation and Operation Guide For

Installation and Operation Guide For Installation and Operation Guide For S23R, S49R, S23F, S49F S23RG, S49RG Refrigerator S23R S49R Freezer S23F S49F Refrigerator S23RG S49RG CONTENTS 1. SPECIFICATIONS 2. SERIAL

More information

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier MANUAL 8/12/05 INSTALLATION, OPERATION & MAINTENANCE Commercial High Efficiency Heat Pipe Dehumidifier Model BKP TM 100 Heat Pipe Technology, Inc. 6904 Parke East Blvd. Tampa FL 33610 Tel: (813) 470-4250

More information

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS SAFETY ALERT SYMBOLS Read and follow all safety information carefully. The signal words used in this manual are selected as shown below and based on an assessment of the degree of potential injury or damage

More information

Model 1870F Dehumidifier Installation and Operating Manual

Model 1870F Dehumidifier Installation and Operating Manual Model 1870F Dehumidifier Installation and Operating Manual ON/OFF button used to turn dehumidifier on and off Up/Down buttons used to change humidity setting Dehumidifer Control Outlet MODE button used

More information

TC-5231 Series, TC-5232, & TC-5241 Series

TC-5231 Series, TC-5232, & TC-5241 Series TC-5231 Series, TC-5232, & TC-5241 Series Low Temperature Thermostats General Instructions Application The TC-5231, TC-5232, and TC-5241 low temperature thermostats are used to control temperature in air

More information

Series 5000 Hydrazine Analyzer Model 60002

Series 5000 Hydrazine Analyzer Model 60002 Series 5000 Hydrazine Analyzer Model 60002 T he patented* Series 5000 Hydrazine Analyzer is a continuous-reading instrument using the p-dimethylaminobenzaldehyde method of analysis for colorimetric measurement

More information

Cabinet Cooler Systems

Cabinet Cooler Systems Cooler Systems Cooler Systems Stop electronic control downtime due to heat, dirt, and moisture! maintain NEMA 4, 4X, and 12 integrity. All are and compliant! What is an EXAIR Cooler System? A low cost,

More information

NoZone Ozone Scrubber

NoZone Ozone Scrubber www.scigene.com NoZone Ozone Scrubber USER GUIDE CAT. #1090 20 3 (115V/220V) Dual Voltage / Universal Adaptor SciGene 1287 Reamwood Avenue, Sunnyvale, CA 94089 USA 408-733-7337 Fax 408-733-7336 techserv@scigene.com

More information

AIR TO AIR HEAT EXCHANGERS

AIR TO AIR HEAT EXCHANGERS AIR TO AIR HEAT EXCHANGERS HEAT PIPE TECHNOLOGY CLOSED LOOP DESIGN AVAILABLE IN 120, 230, 24VDC & 48VDC NEMA TYPE 12, 4 AND 4X UL LISTED FOR STANDARD AND HAZARDOUS LOCATIONS A2A SERIES AIR TO AIR HEAT

More information

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions 3046364 Model No. PE6-10R-03 2011Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.

More information

Product Specifications Warning Light Control Cabinet

Product Specifications Warning Light Control Cabinet NOVA Energy & Automation Product Specifications Warning Light Control Cabinet Model NEAS-RB024D-EWA 03 January 2012 Product Description 1. Standard Applications The Nova NEAS-RB024D-EWA is an integrated

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS U S E R M A N U A L Models: PM15F (shown) PM15P SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: 610-262-6090 Northampton,

More information

INSTRUCTION MANUAL P Heating and 1 Cooling

INSTRUCTION MANUAL P Heating and 1 Cooling REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:

More information

MDH Series Air Dryer. User s Guide

MDH Series Air Dryer. User s Guide MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

SPECTRACOOL Air Conditioner

SPECTRACOOL Air Conditioner INSTRUCTION MANUAL SPECTRACOOL Air Conditioner G28 1-Phase Model Protecting Electronics. Exceeding Expectations. Pentair Technical Products 2100 Hoffman Way Anoka, MN 55303 +1-763-323-8200 +1-763-576-3200

More information

NOREN Products. Compact Cabinet Coolers

NOREN Products. Compact Cabinet Coolers NOREN Products Back to INTRODUCTION Inc. 3 Noren Products Inc. produces a broad range of heat transfer devices incorporating heat pipes. Several of the company's products are widely recognized by their

More information

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz Energy- Saving Mode Portable AC 8,000 BTU Model: MW-O-08C Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

Plug-in Base, Long Range Sensor E3B2

Plug-in Base, Long Range Sensor E3B2 Plug-in Base, Long Range Sensor Plug-in Terminal for Easy Maintenance and Installation Universal AC/DC supply voltage Replace sensing head without rewiring Detect shiny objects with polarized retroreflective

More information

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-5-1 Page: 1 Pre Installation Check to make sure that heater received is the same as that ordered. Watlow heaters are built to comply with UL and CSA dielectric requirements, it may be

More information

Horizon Ice Machine Installation Instructions to Ice Storage Bin Top-mount Applications

Horizon Ice Machine Installation Instructions to Ice Storage Bin Top-mount Applications Stock Module Identification Plate Module No. Product Service No. 208264 MODEL REFRIGERANT VOLTS AMPS AMPS R PART NO CHARGE LOW SIDE C HZ U L R SINGLE PHASE OZ PSIG THE USA MADE IN Horizon Ice Machine Installation

More information

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Issue :-1 Date : - 02/12/15 CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Page 1 of 12 CS90H PACKAGE CONTENTS Item Description Quantity 10590GH-US Dehumidifier 1 3944110 PVC tube 3/8 I/D 7.8 M 3086144 Quick

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

MICRO SWITCH NT Series

MICRO SWITCH NT Series Flat Base Toggle Switch DESCRIPTION Honeywell MICRO SWITCH NT Series toggle switches meet the need for a rugged, cost-effective toggle switch. Quality construction features include a seal between the toggle

More information

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the

More information

Model R060 Installation - Operation Manual

Model R060 Installation - Operation Manual Residential Heat Pump Water Heaters Model R060 Installation - Operation Manual Important Note Read this entire manual before beginning installation Manufactured By: 6670-A Corners Industrial Court Norcross,

More information

Portable Dehumidifier with Internal Pump

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS 115 Pint Portable Dehumidifier With Internal Pump Model Number: DMC-115IP-210 3092402 V161220 PURCHASE INFORMATION Thank you for choosing

More information

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL BUNN HC-1 HC-2 HC-3 DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE:

More information

Installation Instructions CS3 Three Phase Solid State Relay

Installation Instructions CS3 Three Phase Solid State Relay Installation Instructions CS3 Three Phase Solid State elay 1 PK522-3 0037-75550 March 2018 Important Safeguards HIGH VOLTAGE is used in the operation of this equipment; DEATH ON CONTACT may result if personnel

More information

Quest Dry 105, 155, and 205 Dual

Quest Dry 105, 155, and 205 Dual Quest Dry 105, 155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.

More information

MICRO SWITCH BAF/DTF Series

MICRO SWITCH BAF/DTF Series MICRO SWITCH BAF/DTF Series High Capacity Enclosed Switches DESCRIPTION MICRO SWITCH BAF1 high capacity enclosed switches offer elastomer boot on sealed actuator verions that protects the actuating mechanism

More information

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners 763.576.32 Spec-733 C763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Compact Outdoor T15 8 BTU/Hr. 234 Watts T2 2 BTU/Hr. 586 Watts INDUSTRY STANDARDS UL/cUL Listed;

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important

More information

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation. Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator

More information

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through

More information

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC 700 Universal Digital Controllers and Indicator Specifications UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality

More information

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt 763.576.32 SPEC-75 F763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS SPECTRACOOL COMPACT INDOOR N17 115/23 Volt BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527 Watt INDUSTRY STANDARDS UL/cUL Listed;

More information