2 2INSTALLATION MANUAL Novella boilers conform to the basic requirements of the following directives: Gas Appliances Directive 2009/142/CE Boiler Efficiency Directive 92/42/CEE ( ) Electromagnetic Compatibility Directive 2004/108/CE Low Voltage Directive 2006/95/CE Novella boilers are therefore CE marked The following symbols are used in this manual: b CAUTION! = Indicates actions that require caution and adequate preparation a STOP! = Identifies actions that you MUST NOT do

3 CONTENTS 1 SAFETY INFORMATION AND PRECAUTIONS DESCRIPTION OF THE APPLIANCE Description of the appliance Optional accessories Main parts of the boiler Control panel Technical specifications Identification Material supplied Handling Overall dimensions and water fittings Water circuit Wiring diagram INSTALLATION Installation standards Place of installation Installation in existing systems Water connections Electrical connections Gas connections Gas supply conversion Flue gas vent and air intake Filling the water circuit Emptying the water circuit START-UP AND FUNCTIONING Preliminary checks Ignition Final checks SHUT-DOWN MAINTENANCE Scheduled maintenance Extraordinary maintenance OPTIONAL ACCESSORIES... 26

4 4INSTALLATION MANUAL 1 SAFETY INFORMATION AND PRECAUTIONS bbthis manual and the operation manual associated with it form integral parts of the product. Make sure that they are always kept with the boiler even if it is transferred to another owner or user, or re-installed elsewhere. If you damage or lose this manual, order a replacement immediately from your local Technical Assistance Service. bbthe boiler must only be installed and serviced by qualified personnel, in conformity to applicable legislation (in Italy, law 46 of the 05/03/1990) and applicable technical standards (in Italy, UNI- CIG 7129 and 7131 standards and subsequent updates thereto). bbthe boiler must only be used for the purpose for which it is designed. The manufacturer declines all responsibility, contractual or other, for damage to property or injury to persons or animals caused by improper installation, adjustment, maintenance or use. bbas soon as you open the packaging, check immediately that the contents are all present and undamaged. Contact the reseller from whom you purchased the product if you notice any problems. bbthe safety valve must be connected to a suitable collection and drain system. The manufacturer declines all responsibility for damage caused by the operation of an improperly connected safety valve. bbthe following instructions must be passed on to the user on installation of the boiler. - If water leaks from the boiler, turn off the water supply and contact the manufacturer s Technical Assistance Service immediately. - Periodically check that operating pressure in the water circuit is over 1 bar. If necessary, contact the manufacturer s Technical Assistance Service to arrange servicing by professionally qualified personnel. - If the boiler is not going to be used for an extended period of time, contact the manufacturer s Technical Assistance Service to have at least the following operations performed: Switch the boiler OFF at the control panel and at the mains power switch Close the boiler s fuel cock, central heating circuit shut-off cock and domestic hot water circuit shut-off cock Empty the central heating circuit and domestic hot water circuit if there is any risk of freezing - The boiler must be serviced at least once a year. Servicing must be arranged in advance with the manufacturer s Technical Assistance Service Observe the following precautions to ensure safe operation of the boiler. aado not allow children or uninformed persons to operate the boiler. aado not operate any electrical devices or equipment, including switches or domestic appliances, etc., if you can smell fuel or fumes. In the event of a gas leak, thoroughly ventilate the room by opening wide all doors and windows, close the gas shut-off valve and call the manufacturer s Technical Assistance Service immediately to arrange urgent assistance by professionally qualified personnel. aado not touch the boiler while barefoot or wet. aanever clean the boiler without first disconnecting it from the mains electricity supply by turning the mains power switch and the control panel switch OFF. aado not tamper with or adjust the boiler s safety or control devices without prior authorisation and instructions from the manufacturer. aado not pull, disconnect, or twist the electrical cables coming from the boiler even if it is disconnected from the mains electricity supply. aado not obstruct or restrict vents in the room where the boiler is installed. Adequate ventilation is essential for correct combustion. aado not store containers of flammable substances in the room where the boiler is installed. aado not leave items of packaging within the reach of children.

5 2 DESCRIPTION OF THE APPLIANCE 2.1 Description of the appliance Novella boilers are gas fuelled boilers for domestic heating. They are equipped with an atmospheric burner and a cast iron primary heat exchanger. They incorporate an open (type B11BS) combustion chamber and are fitted with a hood that ensures proper flue gas venting even with a fluctuating flue draught. They are also equipped with a flue gas thermostat, as required by applicable safety standards. The burner is a stainless steel unit with stabilised flame and smooth ignition. The burner is fitted with an ionisation type flame detection system. The boiler s control and safety devices conform to applicable technical and safety standards and are enclosed in a functional control panel integrated in the body of the appliance. Novella boilers use total shut-down logic and do not waste energy because they only start up when heat is actually needed by the central heating system (i.e. when the room thermostat trips). Novella boilers can be connected to a storage cylinder to produce domestic hot water, and can be equipped with temperature controllers in the form of specific accessories. Installation, maintenance and access to internal components is facilitated by a large front panel. The key features of these boilers include: electronic ignition with ionisation flame detection adjustable smooth ignition gas supply solenoid valve with built-in pressure stabiliser and double shutter for burner control domestic hot water temperature control water circuit temperature and pressure gauge provision for room thermostat or timer. Novella RAI PV models also feature: central heating circuit pump 12 litre expansion vessel 3 bar central heating circuit safety valve. 2.2 Optional accessories Wall-mounted weekly timer thermostat (part number ) Pump manifold kit (part number ) High head pump kit (part number ) RO120 storage cylinder (part number ) Pump or valve controlled multizone central heating kit with total shut-down function (part number ) Lifting brackets (part number ) 5

6 6INSTALLATION MANUAL 2.3 Main parts of the boiler Novella RAI PV boilers Key 1 Control panel 2 Temperature sensor sockets 3 Boiler body 4 Electronic ignition and flame detection unit 5 CH pump 6 Water circuit drain cock 7 Ignition electrode 8 Flame detection sensor 9 Burner 10 Gas supply solenoid valve 11 Lifting points 12 Expansion vessel Fig. 2.1 Novella RAI boilers Key 13 Control panel 14 Temperature sensor sockets 15 Boiler body 16 Electronic ignition and flame detection unit 17 Ignition electrode 18 Water circuit drain cock 19 Flame detection sensor 20 Burner 21 Gas supply solenoid valve 22 Lifting points Fig. 2.2

7 2.4 Control panel Key 23 Main switch 24 Central heating temperature control 25 Water circuit temperature and pressure gauge 26 Safety thermostat (manual reset) 27 Flue gas thermostat (manual reset) 28 Burner lockout LED warning light 29 Power on LED indicator 30 Quick reference guide 31 Burner reset button Fig Technical specifications 24 RAI PV 24 RAI 31 RAI PV 31 RAI 45 RAI Rated heat input, CH kw 26,6 34,4 50,0 kcal/h Rated heat output, CH kw 24,0 31,0 45,0 kcal/h Electrical consumption W Boiler class II 2H3+ Power supply voltage V ~ Hz 230 ~ 50 Index of protection IP 40 Losses from stack and casing with burner off % 1,65 1,37 1,23 Central heating circuit characteristics Maximum pressure - temperature bar - C CH temperature setting range C Expansion vessel litres Gas pressure Rated gas pressure, methane (G 20) mbar 20 Rated gas pressure, LPG (G31) (G 30 - G 31) mbar 28-30/37 Water connections CH flow return Ø 3/4" Gas inlet Ø 1/2" Emissions with G 20 gas CO below p.p.m CO2 % 5,6 5,7 5,5 NOx (according to EN 297) Class 1 Flue gas Δt C Boiler dimensions Height mm 850 Width mm Depth mm Weight of boiler kg

8 8INSTALLATION MANUAL PARAMETER 24 RAI 31 RAI 45 RAI Lower Wobbe index (at 15 C-1013 mbar) G20 (MJ/m 3 ) 45,5 2.6 Identification (at 15 C-1013 mbar) G30 (MJ/m 3 ) 80,9 (at 15 C-1013 mbar) G31 (MJ/m 3 ) 70,9 Main burner Number of nozzles Nozzle diameter G20 Ø mm 2,40 2,40 2,40 G30 Ø mm 1,50 1,50 1,45 G31 Ø mm 1,50 1,50 1,45 Nozzle pressure (downstream from valve in central heating G20 mbar Δp 13,5 13,5 12,7 only mode) mm H 2 O Δp G30 mbar Δp 28,4 28,0 27,8 mm H 2 O Δp G31 mbar Δp 36,5 34,7 35,7 mm H 2 O Δp Maximum gas flow rate, CH (*) G20 m 3 /h 2,80 3,50 5,10 G30 kg/h 2,09 2,70 3,92 G31 kg/h 2,05 2,66 3,86 (*) Temperature 15 C; Pressure 1013 mbar. Novella boilers are identified by a product name plate giving the boiler s serial number, model and main technical and performance data. bbit is essential to specify the correct model of boiler when ordering spare parts or requesting technical assistance. If the name plate or any other means of clearly identifying the product is defaced, removed or lost, proper installation and servicing may be rendered difficult. GAS FUELLED BOILER Model Serial No. Code PIN Code Year Heat input at Boiler water furnace (Qn/Hi) capacity Useful heat Heat exchanger output (Pn) surface area Maximum working Maximum admissible pressure (mwp) temperature Maximum current Power supply draw Maximum energy NOx class consumption Gas supply pressure Index of protection OBLIGATORY GROUND CONNECTION CLASS OF BOILER TYPE OF BOILER COUNTRY OF DESTINATION Fig. 2.4

9 2.7 Material supplied The boiler is delivered in a wooden cage. Proceed as follows to remove this. Remove the staples fixing the wooden cage to the pallet. Lift off the wooden cage. The following items are delivered in a plastic bag inside the boiler: Operation manual Installation manual LPG conversion kit (nozzles, label, seals). Fig. 2.5 Instruction manuals are integral parts of the boiler. On unpacking, locate the manuals and keep them safe. MODEL 24 RAI 24 RAI PV 31 RAI 31 RAI PV 45 RAI Net weight kg Gross weight kg C 2.8 Handling P Once you have removed the packaging, proceed as follows to handle the boiler. Remove the screws securing the boiler to the wooden pallet. Remove the front panel (P) and top panel (C) from the casing (fig. 2.6). Lift the boiler using two 3/4 pipes (1) pushed through the lifting points (2) (fig. 2.7) Fig. 2.6 bbwear suitable personal protective equipment and use suitable safety devices. aado not leave items of packaging within the reach of children. Fig. 2.7

10 INSTALLATION MANUAL 2.9 Overall dimensions and water fittings Novella 24, 31 RAI PV boilers Novella 24, 31, 45 RAI boilers Fig Fig. 2.9 MODEL DESCRIPTION 24 RAI 24 RAI PV 31 RAI 31 RAI PV 45 RAI A mm B mm

11 2.10 Water circuit Novella 24, 31 RAI PV boilers GAS RI MI E AB D C B F G A A B C D E F Water circuit drain cock Water circuit expansion vessel Water circuit safety valve CH circuit pump CH circuit temperature control sensor Water circuit temperature gauge sensor G Safety thermostat temperature sensor MI CH flow RI CH return AB Storage cylinder connection GAS Gas supply Fig Novella 24, 31, 45 RAI boilers GAS MI B RI A C D A B C D Water circuit drain cock CH circuit temperature control sensor Water circuit temperature gauge sensor Safety thermostat temperature sensor MI CH flow RI CH return GAS Gas supply Fig. 2.11

12 INSTALLATION MANUAL Useful head of pump Novella RAI PV series boilers are pre-fitted with a pump to which all water and electrical connections have already been made. Pump performance is illustrated by the curves in the following graph. Useful head (m approx.) 5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 The pump is configured in the factory to run at maximum speed, i.e. speed III. Slower pump speeds may nevertheless be set with low load loss systems in order to reduce energy consumption. Speed I Speed II Speed III Flow rate (l/h) Fig bbon initial start-up and at least every year, check that all the pumps in the system rotate freely. Sludge and limescale can build up and cause seizure, especially after long periods of disuse. aanever run the pump dry. Fig Boiler s water-side pressure drop Novella RAI boilers come without a pump. A pump must therefore be provided as part of the installation. In order to choose a pump of the right size, bear in mind the boiler s waterside pressure drop, as shown in the following graph. Perdite Pressure di drop carico (m (m.c.a.) approx.) 1,4 1,2 1 0,8 0,6 0,4 0,2 Novella 24, 31 Novella Flow Portata rate (l/h) Fig. 2.14

13 2.11 Wiring diagram PI CH pump AP Ignition and flame detection unit VG Gas supply solenoid valve EA Ignition electrode ER Flame detection sensor 13 IG Main switch FU Fuse LV Green power on LED indicator LR Red burner lockout LED warning light RS Burner reset button TR CH circuit temperature control TS Safety thermostat (manual reset) TF Flue gas thermostat (manual reset) Fig. 2.15

14 INSTALLATION MANUAL 14 3 INSTALLATION 3.1 Installation standards The boiler must be only be installed by qualified personnel in conformity to the following reference standards: UNI-CIG 7129 UNI-CIG 7131 IEC Installers must also ensure conformity to fire prevention standards, gas safety standards and local bylaws. 3.2 Place of installation Novella RAI boilers must be installed in rooms with vents that conform to applicable technical standards and safety legislation. aaboilers must be installed indoors. They are not designed for outdoor use and are not fitted with automatic frost protection devices. IMPORTANT Before installing the boiler, thoroughly flush out all pipes to remove any dirt and deposits that could compromise the correct functioning of the boiler. Install a water collector under the safety valve and connect it to the nearest drain to evacuate any water coming out of the safety in the event of overpressure. The domestic hot water circuit does not require a safety valve but the installer should nevertheless check that the water supply pressure does not exceed 6 bar. If necessary, install a pressure reducer. Before lighting the burner for the first time, make sure that the boiler is configured for use with the type of gas supplied. The type of gas is specified on the packaging label and on the boiler s own name plate. 3.3 Installation in existing systems Perform the following checks before installing Novella boilers in existing systems. Check that the flue is large enough and suitable for the characteristics of the boiler. Check that the characteristics of the boiler s pump (see the graph on page 12) are suitable for the existing system. Existing pumps are no longer needed. Make sure that the central heating circuit has been flushed out to remove all sludge and limescale, and that it has been properly de-aerated. Make sure that the system is fitted with safety and control devices that conform to applicable legislation and standards. Check the hardness of the water supply to ascertain whether a softening system is required. Refer to the following values. REFERENCE VALUES ph 6-8 Electrical conductivity less than 200 mv/cm (25 C) Chlorine ions less than 50 ppm Sulphuric acid ions less than 50 ppm Total iron less than 0,3 ppm Alkalinity M less than 50 ppm Total hardness 35 F Sulphur ions none Ammonia ions none Silicon ions less than 30 ppm Make sure that the flue is able to withstand the temperature of the flue gases and that it has been designed and made in conformity to applicable standards. The flue must also be as straight as possible, sealed, insulated and not blocked or choked.

15 Novella 24, 31 RAI PV 3.4 Water connections MI RI AB Novella boilers are designed and made for use in central heating systems, but can also be used to generate domestic hot water if connected to a suitable storage cylinder. The specifications of the water fittings are as follows. Novella 24, 31 RAI PV boilers MI CH flow 3/4 M RI CH return 3/4 M AB Storage cylinder connection 3/4 M Fig. 3.1 Novella 24, 31 RAI boilers MI CH flow 3/4 M RI CH return 3/4 M Novella 24, 31, 45 RAI MI RI Novella 45 RAI boilers MI CH flow 1 M RI CH return 1 M bbthe choice of system components and the method of their installation are left up to the heating engineer installing the system. Installers must use their expertise to ensure proper installation and functioning in conformity to all applicable legislation. bbcircuits filled with anti-freeze must be fitted with water disconnectors. 15 Fig. 3.2 MODEL DESCRIPTION 24 RAI 31 RAI 45 RAI A mm 3.5 Electrical connections Use a multi-pole disconnector with a contact gap of at least 3 mm to connect the appliance to the mains electricity supply. The appliance functions on an alternating current supply of 230 V, 50 Hz. Consumption is 150 W. The appliance conforms to EN standard. bbthe following instructions are mandatory. - Install a multi-pole magnetic thermal trip switch and disconnector conforming to IEC-EN standards (with a contact gap of at least 3 mm). - Respect the polarity of the L1 (Phase) - N (Neutral) connections. - Use cables with insulation and cross section conforming to applicable standards (minimum cross section 1.5 mm2). - Always refer to the electrical wiring diagrams in this manual when performing any electrical work. - Ensure that an efficient ground connection is provided. a a It is strictly forbidden to use fuel and/ or water pipes to ground the appliance. The manufacturer declines all responsibility for damage caused by failing to ground the appliance adequately.

16 INSTALLATION MANUAL Unscrew the two fixing screws and remove the protective cover (A) from the casing (fig. 3.3). The electrical connection terminals are located underneath (fig. 3.3). Connect up the (optional) room thermostat and/or timer as shown in the electrical wiring diagrams in this manual. Connect up the electrical power supply (fig. 3.4). Fig Fig. 3.4 Connect up the room thermostat (TA) (fig. 3.5). bbif a room thermostat is connected, remove the bridge from terminals 4-5. bbthe contacts of the room thermostat must be able to function at a voltage of 230 V, 50 Hz. Fig. 3.5

17 3.6 Gas connections GAS daia Novella RAI boilers must be connected to the methane or LPG gas supply in conformity to applicable standards (figs. 3.6 and 3.7). Perform the following checks before making the connection. Check that the boiler is compatible with the type of gas supply. Check that the gas supply pipes are thoroughly clean. GAS - Gas supply GAS Fig. 3.6 Fit a suitably sized filter in the gas supply pipe if the gas supply contains any solid particles. bbthe gas supply line must be suitable for the flow rate demanded by the burner. The gas supply must also be equipped with all the necessary safety and control devices required by applicable legislation and standards. bbon completion of the installation, check that all joints are sealed in conformity to the relevant installation standards. MODEL DESCRIPTION 24 RAI 31 RAI 45 RAI A mm 17 GAS - Gas supply Fig Gas supply conversion The boiler comes ready for use with methane gas (G20), but can be converted to work with LPG (G30/G31) using the conversion kit provided. Conversion must be performed by the manufacturer s Technical Assistance Service. The boiler can be converted even after installation. To do so, proceed as follows. Fig. 3.8 REPLACING THE NOZZLES Remove the front panel from the casing. Unscrew the two nozzles from the methane burner and replace them with the LPG nozzles provided in the kit, using the aluminium seals also provided (fig. 3.8).

18 INSTALLATION MANUAL DISABLING THE PRESSURE REGULATOR For the boiler to work with LPG fuel, the pressure regulator on the valve group needs to be disabled. To do so, proceed as follows: Screw the pressure regulator screw (1) all the way in (fig. 3.9). Unscrew the pressure measurement point screw (A) about 3 turns and connect up the pressure gauge (fig. 3.9). SMOOTH IGNITION Turn the ignition adjuster screw (B) to obtain the correct pressure for smooth ignition (fig. 3.10). Start up the boiler as instructed on page 21. NOZZLE PRESSURE Adjust the pressure regulator on the LPG supply until the pressure gauge reads out the value specified in the table below (fig. 3.11): 1 A B Fig. 3.9 Fig RAI 31 RAI 45 RAI G30 G31 G30 G31 G30 G ,4 36,5 28,8 34,7 27,8 35,7 mbar Disconnect the pressure gauge and close the pressure measurement point. Check the tightness of all the joints disconnected previously. Fig Apply the LPG label supplied with the boiler to the inside of the boiler casing (fig. 3.12). Remove any METHANE (G20) labels from the outside and inside of the boiler casing (fig. 3.12). Country of destination: 0694 Boiler configured for: G30+G /37 mbar L.P.G. Country of destination:... Tipo de aparato : C13,C33,C43,C53,C63 Categoría del aparato: II2H3P Presión alimentación gas: G20 20 mbar G31 37 mbar Regulación realizado por el fabricante: G20-20 mbar - 2H METANO ATENCIÓN Leer cuidadosamente el manual de instrucciones antes de la instalación y puesta en servicio de la caldera. Fig. 3.12

19 3.8 Flue gas vent and air intake Fig Flues and stack connections must be made in conformity to all applicable local and national laws and standards. The use of rigid pipes is mandatory. All joints between pipe sections must be hermetically sealed and all parts of the flue must be resistant to high temperatures, condensate and mechanical stress. bbnovella boilers are equipped with a flue gas thermostat, located inside the hood. This thermostat shuts down the boiler immediately in the event of flue gas blowback. bbuninsulated flue pipes are potentially dangerous and can cause burns. MODEL DESCRIPTION 24 RAI 31 RAI 45 RAI B mm Ø I Ø mm 3.9 Filling the water circuit 19 RI Novella RAI boilers must be fitted with a water circuit filling system connected to the central heating return line (fig. 3.14). Fig Make sure that the boiler drain cock is closed before attempting to fill the boiler (fig. 3.5) Fig Open the water circuit shut-off cocks and slowly fill the circuit until the pressure gauge reads out a value of 1.5 bar (cold) Close the water circuit shut-off cocks(fig. 3.16). RI Fig. 3.16

20 INSTALLATION MANUAL 3.10 Emptying the water circuit Turn the electricity supply off by switching the boiler s mains power switch and control panel switch OFF (0) before starting to empty the boiler (fig. 3.17). Make sure that the water circuit shut-off cocks are closed. Connect a rubber hose to the hose union on the boiler s drain cock and open the cock (fig. 3.18). ON OFF Fig Fig

21 4 START-UP AND FUNCTIONING 4.1 Preliminary checks Remove the front panel of the boiler and perform the following checks before switching the boiler on or testing any of its functions. Check that the fuel and water circuit shut-off cocks are open Check that the type and pressure of the gas supply are as specified for the boiler Check that the water circuit pressure gauge shows a pressure over 1 bar with the system cold. Check also that the central heating circuit is properly de-aerated. Check that the pressure in the central heating circuit expansion vessel is sufficient (about 1 bar). Check that the electrical connections to the mains supply and to the system s control and safety devices have been made correctly. Check that the flue is properly constructed. 4.2 Ignition Fig. 4.1 Once you have completed all the preparatory steps, proceed as follows to start up the boiler for the first time. Turn the boiler s mains power switch ON (fig. 4.1). 21 Set the room thermostat to the required temperature (~ 20 C) or, if the system has a timer or timer-thermostat, make sure that this is switched On and adjusted to the required temperature (~ 20 C) (fig. 4.2). Fig. 4.2 Adjust the boiler s own temperature control to the desired temperature (not necessary if the boiler is equipped with a temperature controller) (fig. 4.3). Fig. 4.3 Switch the boiler on at the control panel switch and check that the green power indicator lights (fig. 4.4). Fig. 4.4

22 INSTALLATION MANUAL 22 The boiler will now start up and the burner will remain lit until the set temperature is reached. If any ignition or functioning errors occur, the boiler enters LOCK-OUT and the red LED on the control panel comes on to indicate this (fig. 4.5). Proceed as follows to reset the safety thermostat. Wait for about 1 minute, then press the "burner reset" button (fig. 4.6). Wait for the burner to complete the entire start-up cycle again, up to the ignition of the flame. The boiler will also shut down if the flue gas thermostat trips. To reset the boiler in this case, remove the hood and reset the flue gas thermostat (fig. 4.7). b b If the flue gas thermostat trips repeatedly, make sure that the flue gas pipes are not blocked and that the flue is properly constructed. Fig. 4.5 Fig. 4.6 Fig. 4.7

23 4.3 Final checks Once the boiler has started up, make sure that it shuts down and re-starts properly when the following actions are taken. Fig. 4.8 The boiler s temperature control is turned down (fig. 4.8). The control panel switch is switched OFF (fig. 4.8). Fig. 4.9 The temperature setting on the room thermostat or timer is reduced (fig. 4.9). Make sure that the pump (if fitted) is free and rotates in the right direction (fig. 4.10). Turn the mains power switch OFF and make sure that the boiler shuts down completely. Fig Provided these conditions are satisfied, restart the boiler. ON 23 OFF Fig. 4.11

24 INSTALLATION MANUAL 5 SHUT-DOWN If the boiler is not going to be used for an extended period of time, perform the following operations. Switch the boiler off at the control panel switch and check that the green power indicator goes out (fig. 5.1). Turn the mains power switch OFF (fig. 5.2). Close the boiler s fuel cock and water circuit cocks (fig. 5.3). bbempty the boiler if there is any risk of freezing. ON OFF Fig. 5.1 Fig. 5.2 Fig

25 6 MAINTENANCE To maintain maximum functionality and efficiency, and to comply with applicable legislation, have the boiler serviced at regular intervals. The frequency at which servicing should be performed depends on installation and operating conditions. The boiler should nevertheless be inspected by specialist personnel from the manufacturer s Technical Assistance Service at least once a year. Always switch the boiler off if any work or servicing has to be done on other equipment installed near the flue gas vent pipes and/or flues and associated accessories. On completion of work, have the efficiency of the flue checked by qualified personnel. bbswitch the boiler off at its control panel and at the mains power switch, and turn the gas supply off by closing the gas shut-off cock before performing any cleaning or maintenance on the boiler. 6.1 Scheduled maintenance Scheduled maintenance normally consists of the following operations: Remove encrustations from the burner. Remove encrustations from the heat exchangers. Check and clean the flue pipes. Check the efficiency of the external casing. Check the ignition, normal functioning and shutdown of the boiler in DHW and CH modes. Check the tightness of the gas and water pipe joints. Check gas consumption at maximum and minimum power. Check the position of the ignition electrode and flame detection sensor. Check the gas failure safety system. Do not use flammable substances (e.g. petrol, alcohol etc.) to clean the boiler or any of its parts. Do not use paint thinners to clean the casing or any painted or plastic parts of the boiler. Use only soapy water to clean the boiler casing. 6.2 Extraordinary maintenance Extraordinary maintenance involves actions designed to restore the functioning of the boiler to its design specifications and to ensure conformity to legal requirements after a failure or malfunction. These actions can be: Replacement of parts Repairs Reconditioning of parts. These actions generally require special tools and equipment. 25

26 INSTALLATION MANUAL 7 OPTIONAL ACCESSORIES Wall-mounted weekly timer thermostat (fig. 7.1) (part number ). Pump or valve controlled multizone central heating kit with total shut-down function (fig. 7.2) (part number ). Fig. 7.1 Fig. 7.2 RO120 storage cylinder (fig. 7.3) (part number ). 26 Fig. 7.3 Pump manifold (fig. 7.4) (part number ). Fig. 7.4 High head pump (fig. 7.5) (part number ). Fig. 7.5

27

28 Cod /12 Ed. 0 Via Risorgimento, Lecco (LC) Servizio Clienti * Assistenza Tecnica Numero Unico * Beretta is constantly improving its products and therefore reserves the right to modify the characteristics and specifications of the appliance described in this manual at any time and without prior notice. The contents of this manual are not contractually binding on the manufacturer.

NOVELLA RAI BOILERS CAST IRON BASE INSTALLATION MANUAL

NOVELLA RAI BOILERS CAST IRON BASE INSTALLATION MANUAL NOVELLA 55-64-71 RAI BOILERS CAST IRON BASE INSTALLATION MANUAL 2INSTALLATION MANUAL Novella boilers conform to the basic requirements of the following directives: Gas Appliances Directive 2009/142/CE

More information

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA PLUS DS Solar Solar storage cylinder EN Installation and Operation Manual GENERAL INFORMATION This - comprises pages. Rev. manual, Code ENGLISH General information

More information

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual Installation Manual STOR C Solar combination storage cylinder EN Installation Manual 2MANUALE INSTALLATORE Dear Installer, Thank you for choosing a BERETTA STOR C, combination storage cylinder. You have

More information

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONTROL PANEL RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL Lecco, 18th January 12 The company Riello SpA Heating Products Direction Via Risorgimento 13 23900 Lecco ITALY hereby declares

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL idealtech PRIME CONTROL PANEL For Users Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONTROL PANEL RIELLOtech PRIME INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONFORMITY RIELLOtech control panels conform to: Low Voltage Directive 06/95/EC (ex-directive 73/23/EEC) Electromagnetic Compatibility

More information

INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL THE/TG

INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL THE/TG INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL THE/TG CONFORMITY The THERMITAL THE/TG S boilers conform to the Efficiency Directive 92/42/CEE. When used in conjunction with a CE marked

More information

HYBRID STOR

HYBRID STOR Installation Manual 430-550 - 750-1000 Solar combination storage cylinder triple coil EN Installation Manual 2INSTALLATION MANUAL Dear Installer, Thank you for choosing a BERETTA, combination storage cylinder.

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

cod. Doc rev. 2 12/ ACI PLUS EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

cod. Doc rev. 2 12/ ACI PLUS EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL cod. Doc-0072750 rev. 2 2/206 7000 ACI PLUS EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL RANGE MODEL CODE RIELLO 7000 ACI 60 PLUS 2000056 RIELLO 7000 ACI 20 PLUS 20082450 RIELLO 7000 ACI 200 PLUS

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

solar storage cylinder

solar storage cylinder solar storage cylinder IDRA DS SOLAR INSTALLATION MANUAL USER MANUAL Range MODEL CODE BERETTA IDRA DS 200 20001224 BERETTA IDRA DS 300 20001225 BERETTA IDRA DS 430 20001226 BERETTA IDRA DS 550 20001227

More information

USER MANUAL ACQUAHOME 32 B BLU

USER MANUAL ACQUAHOME 32 B BLU USER MANUAL ACQUAHOME 32 B BLU Dear Customer, Thank you for preferring a T heating unit, a modern, high-quality product that is able to guarantee your maximum well-being for a long period of time, with

More information

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its diesel-burning boilers are produced in accordance with the requirements of article 3 paragraph 3 of Directive PED 97/23/EEC

More information

TAHITI CONDENSING KR 55 - KR 85

TAHITI CONDENSING KR 55 - KR 85 IST 03 C 351-01 TAHITI CONDENSING KR 55 - KR 85 GB INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully. They will

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

CAST IRON ATMOSPHERIC BOILERS

CAST IRON ATMOSPHERIC BOILERS CST IRON TMOSPHERIC OILERS 006 gas-fired, central heating only, electronic ignition High efficiency boilers designed heating large domestic application. Ideal for installation in any boiler room. Cast-iron

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

cod rev. 2 06/2016 GITRÈ LN EN INSTALLATION AND MAINTENANCE MANUAL

cod rev. 2 06/2016 GITRÈ LN EN INSTALLATION AND MAINTENANCE MANUAL cod. 05 rev. 06/06 GITRÈ LN GITRÈ B/00 LN GITRÈ LN EN INSTALLATION AND MAINTENANCE MANUAL Dear heating engineer, Congratulations on having chosen a R boiler. You have selected a modern, quality product

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA N DS Solar solar storage cylinder EN Installation and Operation Manual 2 Dear Customer, Thank you for choosing a B solar storage cylinder. You have purchased a modern,

More information

CONDENSING BOILERS 45 B - 55 B INSTALLATION AND MAINTENANCE MANUAL GENERAL 1

CONDENSING BOILERS 45 B - 55 B INSTALLATION AND MAINTENANCE MANUAL GENERAL 1 CONDENSING BOILERS 45 B - 55 B INSTALLATION AND MAINTENANCE MANUAL GENERAL CONFORMITY INSIEME CONDENS r condensing boilers conform to the following directives: Efficiency Directive 9/4/EEC (HHHH) EN 677

More information

Installation and Operation Manual IDRA MS 150. Solar solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA MS 150. Solar solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA MS 150 Solar solar storage cylinder EN Installation and Operation Manual Range MODEL CODE IDRA MS 150 20072887 ACCESSORIES For a complete list of accessories and

More information

Heating Equipment. gas boilers RX GB. installation and servicing instructions

Heating Equipment. gas boilers RX GB. installation and servicing instructions Heating Equipment gas boilers RX GB installation and servicing instructions CONTENTS 1 TECHNICAL FEATURES AND DIMENSIONS 1.1 BOILER DESCRIPTION.............................................. page 1 1.2

More information

Gas Instantaneous Water Heater

Gas Instantaneous Water Heater 6 720 607 823 GB (06.06) SM Installation and Operating Instructions Gas Instantaneous Water Heater WR10..B... WR11..B... With electronic ignition and triple safety system consisting of ionisation detector,

More information

INSTALLATION AND MAINTENANCE MANUAL

INSTALLATION AND MAINTENANCE MANUAL CONDENSING BOILERS B - BK 5 B - 5 BK INSTALLATION AND MAINTENANCE MANUAL BK 5 BK B 5 B CONFORMITY INSIEME CONDENS r condensing boilers conform to the following directives: Directive 9//EEC on efficiency

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE IST 03 C 202-01 ELBA DUAL INSTALLATION, USE AND MAINTENANCE GB Thank you for choosing our boilers. Please read these installation and maintenance instructions with care. Please note that the boiler must

More information

CONNECT SOLAR MR - 7,5m

CONNECT SOLAR MR - 7,5m Installation Manual CONNECT SOLAR MR - 7,m Solar Solar station EN Installation Manual 0 6 GENERAL INFORMATION ENGLISH General information This - comprises pages. Rev. manual, Code RANGE MODEL CODE CONNECT

More information

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C LIBRA DUAL High quality Italian product GB INSTALLATION USE AND MAINTENANCE IST 04 C 220-02 Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully

More information

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing

More information

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers Wall mounted condensing boilers VICTRIX 50 is the new wall-mounted central heating condensing boiler. It is pre-arranged for single and cascade operation (up to 3 appliances connected), with the advantage

More information

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

RESIDENCE COLONNA CONDENS INSTALLATION AND MAINTENANCE MANUAL

RESIDENCE COLONNA CONDENS INSTALLATION AND MAINTENANCE MANUAL FLOOR STANDING CONDENSING BOILERS RESIDENCE COLONNA CONDENS KV/130 30 ISC INSTALLATION AND MAINTENANCE MANUAL CONFORMITY r RESIDENCE COLONNA CONDENS boilers conform to the following directives: Gas Appliances

More information

RMG IT ES PT GB FR BE

RMG IT ES PT GB FR BE RMG IT ES PT GB FR BE INSTALLER INSTRUCTIONS ENGLISH CONTENTS 1 DESCRIPTION OF THE BOILER........................................................................ pag. 38 2 INSTALLATION.......................................................................................

More information

SPECIFICATIONS - NIKE

SPECIFICATIONS - NIKE Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks

More information

Installation and Operation Manual IDRA DS LE. Solar Solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA DS LE. Solar Solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA DS LE Solar Solar storage cylinder EN Installation and Operation Manual Dear Customer, Thank you for choosing a B solar storage cylinder. You have purchased a modern,

More information

cod rev. 4 08/ Kombisolar 2S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

cod rev. 4 08/ Kombisolar 2S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL cod. 20089319 rev. 4 08/2015 7200 Kombisolar 2S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL Range Model Code KOMBISOLAR 430 2S 20088789 KOMBISOLAR 550 2S 20088790 KOMBISOLAR 750 2S 20088951 KOMBISOLAR

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

POWER. Installation, user and maintenance manual. Cast-iron wood gasification boiler. The section for the user is at the end of the manual

POWER. Installation, user and maintenance manual. Cast-iron wood gasification boiler. The section for the user is at the end of the manual Cast-iron wood gasification boiler POWER Installation, user and maintenance manual The section for the user is at the end of the manual The appliance must be installed by qualified personnel in compliance

More information

VICTRIX Superior kw Export VICTRIX Superior kw X Export

VICTRIX Superior kw Export VICTRIX Superior kw X Export Wall-hung condensing VICTRIX Superior kw is the instantaneous sealed chamber wallhung boiler with power of 32 kw which, thanks to condensation technology, is characterised for its high efficiency and guarantees

More information

RODI DUAL RODI DUAL HR

RODI DUAL RODI DUAL HR IST 03 C 320-04 RODI DUAL RODI DUAL HR PRESSURISED STEEL BOILER EN INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you selecting our company and choosing to purchase our products. We invite you to

More information

USER MANUAL. 60cm, 3 burners, Hob AKC 630

USER MANUAL. 60cm, 3 burners, Hob AKC 630 USER MANUAL 60cm, 3 burners, Hob AKC 630 For your safety These instructions have been drawn up for your safety and that of others. You are therefore requested to read them carefully before installing

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

cod rev. 0 03/ Kombisolar 3S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

cod rev. 0 03/ Kombisolar 3S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL cod. 20139323 rev. 0 03/2018 7200 Kombisolar 3S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL ENGLISH RANGE Model Code KOMBISOLAR 430 3S 20139026 KOMBISOLAR 550 3S 20139044 KOMBISOLAR 750 3S 20010139

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

USER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM

USER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM USER MANUAL 80 cm 2 burners, glass hob AKC 820C/BLM For your safety These instructions have been drawn up for your safety and that of others. You are therefore requested to read them carefully before installing

More information

STEEL BOILERS RTS 3S INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL

STEEL BOILERS RTS 3S INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL STEEL BOILERS RTS S INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL CONFORMITY r RTS S boilers conform to the Efficiency Directive 92/42/CEE. When used in conjunction with a CE marked

More information

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA N DS Solar solar storage cylinder EN Installation and Operation Manual 2 This - comprises pages. Rev. manual, Code Dear heating engineer, We would like to congratulate

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

WARNINGS FOR THE USER: Connect BASE conforms to: Low Voltage Directive 73/23/EEC. Electromagnetic Compatibility Directive 89/336/EEC

WARNINGS FOR THE USER: Connect BASE conforms to: Low Voltage Directive 73/23/EEC. Electromagnetic Compatibility Directive 89/336/EEC Connect BASE conforms to: Low Voltage Directive 73/23/EEC Electromagnetic Compatibility Directive 89/336/EEC Warnings and safety considerations Page 13 Description of the equipment 14 Technical data 14

More information

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150 Wall Mounted Fan Flue System boiler Appr. nr. B 94.04 A - CE 0063 AQ 2150 Phone numbers: Installer Service Engineer Serial N Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS Please read

More information

Operating instructions

Operating instructions Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...

More information

Proline GAS HOB Model TCG40IX Instruction Book

Proline GAS HOB Model TCG40IX Instruction Book Proline GAS HOB Model TCG40IX Instruction Book GB Operating and Installation Instructions Index Technical data and specifications...... 3 Installation...................... 3-6 Ventilation........................

More information

The guarantee on this appliance is valid for 12 months from the first day of installation.

The guarantee on this appliance is valid for 12 months from the first day of installation. Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Models: Verso 4G Hob As part of Parmco Appliances commitment to improving and updating product ranges, we reserve the right to alter, change and update technical

More information

BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set.

BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set. BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number

More information

Mikrofill Ethos Condensing combination boiler

Mikrofill Ethos Condensing combination boiler Mikrofill Ethos Condensing combination boiler User Instructions 24cc CE Mark Mikrofill gas appliances comply with the requirements contained in CE Mark documents contained with European directives applicable

More information

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

WHE 2.24 / WHE 2.24 FF

WHE 2.24 / WHE 2.24 FF EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3

More information

User Manual for model

User Manual for model User Manual for model RKA 24/8 RKA 24 RKA 28 RKA 34 Wall mounted storage combi boiler premix condensing boiler User instruction CE 0694 RKA 24.8_24_28_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO

More information

INSTALLATION, TECHNICAL ASSISTANCE CENTRE AND SYSTEM MANAGEMENT MANUAL THC V E OIL BLU

INSTALLATION, TECHNICAL ASSISTANCE CENTRE AND SYSTEM MANAGEMENT MANUAL THC V E OIL BLU INSTALLATION, TECHNICAL ASSISTANCE CENTRE AND SYSTEM MANAGEMENT MANUAL THC V E OIL BLU Conformity THC V E OIL BLU condensing boilers conform to the following directives: Efficiency Directive 92/42/EEC

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical

More information

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM 3gb53231b.fm5 Page 12 Friday, April 11, 2003 12:21 PM INSTRUCTIONS FOR USE BEFORE USING THE COOKTOP SUGGESTIONS FOR ENVIRONMENT PROTECTION PRECAUTIONS AND GENERAL ADVICE ENERGY SAVING TIPS CARE AND MAINTENANCE

More information

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS ZENA PLUS WALL-HUNG GAS BOILERS MSL FF: from. to 1 kw for heating only MSL FF + BMR 80 and MSL FF + SR 10: from. to 1 kw for heating and DHW produced by an 80-litre calorifier placed beside the boiler,

More information

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on

More information

INSTRUCTIONS FOR HOBS PISL1CZI PISL20ZI PISL40ZI PISL40Z* PISL4CZI PISL904CZI PISL1004CZI PISL1163CZI PISF4CZI PISF904CZI PISF1004CZI PISF1163CZI

INSTRUCTIONS FOR HOBS PISL1CZI PISL20ZI PISL40ZI PISL40Z* PISL4CZI PISL904CZI PISL1004CZI PISL1163CZI PISF4CZI PISF904CZI PISF1004CZI PISF1163CZI Select-Abey.rev05 INSTRUCTIONS FOR INSTALLATION AND USE HOBS PISL1CZI PISL20ZI PISL40ZI PISL40Z* PISL4CZI PISL904CZI PISL1004CZI PISL1163CZI PISF4CZI PISF904CZI PISF1004CZI PISF1163CZI CONTROLS ZONE -

More information

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14 Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification

More information

Ciao Green Condensing Wall-Hung Boilers

Ciao Green Condensing Wall-Hung Boilers Ciao Green Condensing Wall-Hung Boilers Residential Heating Ciao Green A cost-consciuos condensing boiler CIAO GREEN is one of the condensing boilers with the best price-quality ratio on the matket. Kitchen

More information

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank 1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO

More information

VELA COMPACT INSTALLATION USE AND MAINTENANCE

VELA COMPACT INSTALLATION USE AND MAINTENANCE VELA COMPACT GB INSTALLATION USE AND MAINTENANCE IST 04 C 167-04 Dear Customer, Thank you for choosing and buying one of our boilers. Please read these instructions carefully in order to install, operate,

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING MADE IN ITALY residential condensing D.H.W. up to 10 bar WORKING PRESSURE AISI 316 Ti TITANIUM D.H.W. 100% CONDENSING AGUAdens TM wall-mounted water heaters (16-22 -37 litres) AGUAdensTM INSTANTANEOUS

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL IST 03 C 484-02 ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL Dear Customer, Thank You for choosing and buying one of our boilers. Please read these instructions carefully in order to properly

More information

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB / GB 99-11-03/01 1-18 Index 1 WORKING AND FITTED DIMENSIONS 3 1.1 Oven size 60 cm 3 1.2 Maxioven 4 2 INSTALLING THE FITTED OVEN 5 3 FITTED GAS - INSTALLATION REQUIREMENTS 5 4 FIXING THE OVEN TO THE UNIT

More information

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This

More information

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by

More information

Contents. 1. Instructions for safety and use 20

Contents. 1. Instructions for safety and use 20 Contents 1. Instructions for safety and use 20 2. Positioning in the counter top 21 2.1 Fixing to the supporting structure 21 2.2 Positioning the adhesive sponge 22 2.3 Positioning the fastening clips

More information

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB 6 720 648 662-00.1T UNI 7000 F Operating instructions For the user AU/G 2 Contents Contents Contents 2 1 Safety information and explanation of symbols 3 1.1 For your safety 3 1.2 Explanation of symbols

More information

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE PEGASUS F2 N 2S CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE cod. 3544309/0 ediz. 01/2003 Carefully read the warnings in

More information

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A... Residential Gas Condensing Boiler Greenstar combi 00 p / 5 p ZWB8-3A... ZWB4-3A... Operating Instructions 708733 (07/04) US/CA Contents Contents Explanation of symbols and safety instructions.......................

More information

UBGHFF60W 60cm Gas on Glass Gas Hob

UBGHFF60W 60cm Gas on Glass Gas Hob UBGHFF60W 60cm Gas on Glass Gas Hob GB [02] x 1 [03] x 2 [04] x 1 [01] x 1 [08] x 4 [05] x 2 [09] x 1 [06] x 1 [07] x 4 [10] x 4 [11] x 1 TEMPLATE TEMPLATE UBGHFF60W GB Built-in 60cm Gas on Glass Gas Hob

More information

Installation and Operation Manual IDRA MS 150 LE. Solar Solar storage cylinder. Installation and Operation Manual

Installation and Operation Manual IDRA MS 150 LE. Solar Solar storage cylinder. Installation and Operation Manual Installation and Operation Manual IDRA MS 150 LE Solar Solar storage cylinder EN Installation and Operation Manual Dear Customer, Thank you for choosing a B solar storage cylinder. You have purchased a

More information

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters  T (0) Installation & Operating Manual ZM-130 16 32kW Universal Oil Heater OVERVIEW Dfdfdfdsfd Dfdfffdfdf Dfdfdf 4 1. Overheat thermostat 2. Combustion chamber lid 3. Oil feed line 4. Activation thermostat 5.

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon

More information

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18 INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG Page 1 / 18 CHAP 1 - INSTRUCTIONS TO PREVENT ACCIDENTS Keep this manual carefully to be able to refer to it in every case of need. Keep appliance

More information

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Instrucciones para la instalación, uso y mantenimiento

More information

CONDENSING BOILERS TAU UNIT OIL 35 G OIL 55 G INSTALLATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL

CONDENSING BOILERS TAU UNIT OIL 35 G OIL 55 G INSTALLATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL CONDENSING BOILERS TAU UNIT OIL 35 G OIL 55 G INSTALLATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL Conformity TAU UNIT OIL r condensing boilers conform to the following directives: Efficiency Directive

More information

TAHITI DUAL HC - HR INSTALLATION, USE AND MAINTENANCE. Italian product. High quality

TAHITI DUAL HC - HR INSTALLATION, USE AND MAINTENANCE. Italian product. High quality TAHITI DUAL HC - HR GB Gas fired wall Mounted condensing boiler Tahiti Dual 24-32 kw Combi (HC) Tahiti Dual 24-32 kw Regular (HR) High quality Italian product INSTALLATION, USE AND MAINTENANCE MADE IN

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information