WBV/WV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

Size: px
Start display at page:

Download "WBV/WV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency."

Transcription

1 Series Oil WBV/WV Boilers Plastic Jacket As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Installation, Operation & Maintenance Manual

2 TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. INSTALLATION CLEARANCE B. SPECIAL ATTENTION BOXES PREINSTALLATION 2 A. CLEARANCES B. AIR FOR COMBUSTION AND VENTILATION C. CHIMNEY / VENT AND DRAFT CONTROL..3 D. INSTALLATION SURVEY E. PLANNING THE LAYOUT BOILER PLACEMENT AND ASSEMBLY 5 A. SETTING THE BOILER B. CONNECTING THE FLUE OUTLET WATER PIPING 6 A. GENERAL B. SYSTEM COMPONENTS C. SYSTEM PIPING D. FREEZE PROTECTION E. SPECIAL APPLICATIONS F. TANKLESS HEATER OR COVERPLATE G. CONTROLS BURNER SETUP & BOILER OPERATION 11 A. BURNER INSTALLATION B. BURNER START-UP AND ADJUSTMENT..11 C. CHECK BOILER CONTROLS D. PURGE AIR FROM THE SYSTEM (WATER BOILERS ONLY) ELECTRICAL 14 A. GENERAL B. WIRING MAINTENANCE 17 A. GENERAL B. DAILY MAINTENANCE (WITH BOILER OPERATING) C. WEEKLY MAINTENANCE (WITH BOILER OPERATING) D. MAINTENANCE OF SAFETY RELIEF VALVE E. MONTHLY MAINTENANCE (WITH BOILER OPERATING) F. MAINTENANCE ANNUAL G. WATERSIDE INSPECTION H. INSPECT HEAT DISTRIBUTION SYSTEM..19 I. IF A LONG SHUTDOWN IS REQUIRED BOILER DIMENSIONS & RATINGS REPAIR PARTS 22

3 USING THIS MANUAL USING THIS MANUAL A. INSTALLATION CLEARANCE Follow the installation instructions provided in this manual in the order shown. The order of these instructions has been set in order to provide the installer with a logical sequence of steps that will minimize potential interferences and maximize safety during boiler installation. B. SPECIAL ATTENTION BOXES Throughout this manual you will see special attention boxes intended to supplement the instructions and make special notice of potential hazards. These categories mean, in the judgment of PB Heat, LLC: DANGER Indicates a condition or hazard which will cause severe personal injury, death or major property damage. WARNING Indicates a condition or hazard which may cause severe personal injury, death or major property damage. CAUTION Indicates a condition or hazard which will cause minor personal injury or property damage. NOTICE Indicates special attention is needed, but not directly related to potential injury or property damage. NOTICE In accordance with Section 325 (f) (3) of the Energy Policy and Conservation Act, this boiler is equipped with a feature that saves energy by reducing the boiler water temperature as the heating load decreases. This feature is equipped with an override which is provided primarily to permit the use of an external energy management system that serves the same function. THIS OVERRIDE MUST NOT BE USED UNLESS AT LEAST ONE OF THE FOLLOWING CONDITIONS IS TRUE: An external energy management system is installed that reduces the boiler water temperature as the heating load decreases. This boiler is not used for any space heating. This boiler is part of a modular or multiple boiler system having a total input of 300,000 BTU/hr or greater. This boiler is equipped with a tankless coil. 1

4 PREINSTALLATION 1. PREINSTALLATION Read carefully, study these instructions before beginning work. It will save time. Study the included drawings. Save these instructions for reference. This boiler must be installed by a qualified contractor. The boiler warranty can be voided if the boiler is not installed, maintained and serviced correctly. NOTICE The equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made, including the current edition of NFPA-31, Standard for the Installation of Oil-Burning Equipment, and in Canada, CSA B139, Installation Code for Oil Burner Equipment. These shall be carefully followed in all cases. Authorities having jurisdiction shall be consulted before installations are made. A. CLEARANCES CAUTION Never burn garbage or paper in the unit, and never leave combustible material around it. CAUTION Do not tamper with boiler controls. Unit may be installed on combustible flooring, provided the boiler is not set on carpet and a metal drip pan is placed under the appliance. Unit may be installed in a closet with the below clearances. See also Section B, Air for Combustion and Ventilation. DANGER Do not install this appliance on carpeting. WARNING Do not install this appliance where gasoline or other flammable liquids are stored or are in use. Do not store clothing or combustible materials on or against the venting system or jacket. B. AIR FOR COMBUSTION AND VENTILATION 1. Be certain adequate facilities are available to provide air for satisfactory combustion and ventilation. 2. Appliances Located in Unconfined Spaces. a. For installation in unconfined spaces with conventional construction and larger areas such as basements, the supply of air for combustion and ventilation can usually be considered adequate. Figure 1.1: Appliance Installation Clearances 2

5 PREINSTALLATION 3. Appliances Located in Confined Spaces. a. All air from inside the building: Provide two permanent openings communicating directly with an additional room. If all air for combustion and ventilation is to come from within the building: two openings, one near the ceiling and one near the floor of the boiler room shall be provided with the minimum free area of each opening equal to 140 sq. in. per gallon of oil burned. b. If all air for combustion and ventilation is to come from outside the building: two openings, one near the ceiling and one near the floor of the boiler room shall be provided with the minimum free area of each opening equal to 35 sq. in. per gallon of oil burned. If ducts are used to convey the air, areas of 35 sq. in. per gallon of oil burned for vertical ducts or 70 sq. in. per gallon of oil burned for horizontal ducts are to be provided. Ducts shall have the same area as the free area of the openings to which they are connected. 4. Special Conditions: If the boiler is located in areas with exhaust fans, direct-fired water heaters or fireplaces can create conditions for unsatisfactory combustion or venting, special provisions must be made. 5. Specially Engineered Installations: The size of the combustion air openings in this section may not apply to specially engineered systems. These systems are to be designed to ensure adequate supply of air for combustion and ventilation. CAUTION Do not install this appliance where corrosive materials, such as ammonia, chlorine, water softener salt, etc. are stored. C. CHIMNEY / VENT AND DRAFT CONTROL CAUTION An oil-fired unit shall be connected to a flue having sufficient draft at all times, to assure safe proper operation of the unit. 1. Draft Requirement Minimum draft required in the vent system is -0.03" to -0.03" W.C. depending on boiler model, see Table 7.1 (Section 7). This draft is necessary to provide the necessary draft over fire of -0.01" to -0.02" W.C. See discussion in paragraph 5 below regarding draft. 2. A barometric draft control is recommended for regulation of overfire draft. Follow manufacturer's instructions to locate and adjust the control. 3. Inspect the existing chimney or vent system. Make sure it is in good condition. Inspect chimney liner and repair or replace if necessary. 4. The vent system and installation must be in accordance with the current edition of the American National Standard ANSI/NFPA 211, "Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances," or applicable provisions of the local building codes. Typical minimum chimney size is 8" x 8", 15 feet high, unless otherwise allowed by code. If the vent system is not sized properly, the burner may not operate properly. This can cause poor combustion, sooting and odors to occur. 5. Background Information Regarding Draft: Modern boilers operate with higher efficiencies than older boilers. Smaller flueways, as well as bars, pins and fins are designed into modern boilers to transfer as much heat as possible from the hot gases to the water or steam and prevent heat loss up the chimney. However, these design features result in higher pressure, or draft loss, in the boiler. This draft loss must be taken into account when installing an oil boiler into a new or old chimney. New chimneys are less likely to have poor draft. However, they must have sufficient draft to support combustion. A -0.06" draft is desirable and preferred. Older chimneys may require a replacement liner to have them perform well enough to support combustion. For Example: Chimney Draft Boiler Design Pressure Drop Draft Over Fire Old Installation New Installation -0.04" -0.04" +0.01" +0.01" -0.03" -0.00" Comments No change, but older chimneys (especially unlined ones) have leaks which reduce draft. Required for mandated efficiency increases. The old installation would have had a higher temperature in the chimney [as high as 800 degrees vs. 400 degrees F], which would increase the draft. The above readings are "cold" readings (before the boiler and chimney are heated up). Note also that the higher the firing rate on a unit which has multiple firing rates, the higher the draft required. For example, increasing the firing rate 1/4 gallon may increase the draft loss in a unit by approximately +0.01". 3

6 PREINSTALLATION D. INSTALLATION SURVEY For new and existing installations, a Water Installation Survey or a Steam Installation Survey is available from P.B. Heat, LLC. The surveys will provide information on how the boiler works with your specific system and will provide an overview of boiler system operation in general. You can also use this survey to locate system problems which will have to be corrected. To obtain copies of these Surveys, contact your PB Heat representative or download it from PeerlessBoilers.com. E. PLANNING THE LAYOUT Prepare sketches and notes of the layout of the installation. Include boiler location, venting system, existing piping and wiring. Show existing equipment that may interfere with installation of new equipment. 4

7 BOILER PLACEMENT AND ASSEMBLY 2. BOILER PLACEMENT AND ASSEMBLY A. SETTING THE BOILER 1. Provide a level foundation, located as close as possible to the center of the heating system. 2. Refer to Figure 8.1 for exploded view of boiler while checking and/or assembling parts of the boiler. 3. On packaged boilers, open burner mounting plate (item 5) at this time to make certain the target wall (item 2) is seated in the back of the combustion chamber. (WBV-04 /WV-05 ) Ceramic fiber blanket base liner (item 3) should be lying flat on bottom of combustion chamber between target wall and burner mounting plate. Close burner mounting plate. 4. See clearance information in Section 1, "Preinstallation." B. CONNECTING THE FLUE OUTLET The WBV-03 and WBV-04 boiler models may be installed as a rear flue outlet unit or a top flue outlet unit. Packaged WBV-03 and WBV-04 boiler models are shipped as rear flue outlet and may be converted. The WV-05 boiler model is only available as a top flue outlet unit. On Knockdown boilers, the flue outlet components are located in the water trim or steam trim carton. 1. If converting to a top flue application on a packaged boiler, remove top jacket panel and remove the large knockout in the jacket top panel. A stub vent will be required to extend the vent above the jacket top panel (not provided). 2. Remove the rear outlet cover plate (Item 13 Figure 8.1) and mount the flue collar to the flue collector plate (Item 11 Figure 8.1) with the 4 #12 screws. 3. Attach the rear outlet cover plate (item 13) to the rear outlet opening using four (4) 5/16" bolts and washers provided. 5

8 WATER PIPING 3. WATER PIPING A. GENERAL 1. Follow these instructions closely in order to be sure that the boiler operates as it is intended. Water piping is extremely important to the system operation. 2. Size water supply and return piping in accordance with system requirements. 3. If the WBV/WV boiler is replacing and existing boiler, make sure that the system piping is thoroughly cleaned and free from debris before installing this boiler. 4. Install this boiler so that the oil burner and limit controls are protected from water (dripping, spraying, etc.) during operation and service. 5. The WBV/WV boiler is designed to operate in a closed loop hydronic system under forced circulation. However, there is no minimum water flow rate for this boiler. B. SYSTEM COMPONENTS Figure 3.1 shows the symbol key for the piping diagrams in this section. The following are brief descriptions of system components. 1. Pressure/Temperature Gauge: A combination pressure/temperature gauge is provided with each WBV/WV boiler to be mounted in the supply (outlet) piping as shown in figure 3.2. Most local codes require this gauge. 2. Air Elimination: Closed loop hydronic systems require air elimination devices. As the system water is heated, dissolved oxygen and other gases will separate from the liquid. An air elimination device (such as a TACO Vortech Air Separator) is required to remove the dissolved gases preventing corrosion in the piping system and eliminating noise. Figure 3.1: Symbol Key 6

9 WATER PIPING 6. Back Flow Preventer: A back flow preventer (check valve) is required by some jurisdictions to prevent water in the hydronic system from backing up into the city water supply if the supply pressure drops below that of the heating system. This is especially important on systems in which glycol solution is used as a heating medium. 7. Pressure Relief Valve: The boiler pressure relief valve is shipped separately for field installation. On the WBV/WV boiler, this can be piped into the connection provided next to the boiler supply (outlet) connection or, alternatively, on the connection at the rear of the boiler below the supply. The value is to be installed as shown in Figure 3.2. Figure 3.2: Pressure/Temperature Gauge & Relief Valve Piping 3. Expansion Tank: An expansion tank (such as a Bell & Gossett Series HFT) is required to provide room for expansion of the heating medium (water or glycol solution). Consult the expansion tank manufacturer s instruction for specific sizing information. The expansion tank is to be sized for the required system volume and capacity. In addition, care must be taken to size the expansion tank based on the proper heating medium. Glycol solutions may expand more than water for a similar temperature rise. Table 3.1 shows the approximate water volume of the boiler for sizing the expansion tank and determining glycol solution concentration. Table 3.1: Boiler Water Volume Boiler Model Water Volume, Gal (Liter) WBV (44.5) WBV (55.8) WV (67.1) 4. Flow Control Valve (Check Valve): Flow control valves or check valves are used to prevent gravity circulation by incorporating a weighted disc into the check valve. These valves also prevent problems with reverse circulation through parallel heating loops which cause erratic behavior of the heating system and prevent heat from reaching its intended load. 5. Pressure Reducing Valve: A pressure reducing valve, such as the Bell & Gossett B-38 or a TACO #29, is used in a hydronic system to automatically feed water to the system whenever the pressure drops below the set pressure. These valves should not be used on glycol systems unless close supervision of the glycol solution is practiced. WARNING Do not operate this appliance without installing the pressure relief valve supplied with the boiler or one with sufficient relieving capacity in accordance with the ASME Rating Plate on the boiler. Pipe the discharge of the safety relief valve to within 12" of the floor and close to an open drain. The discharge piping must be the same size or larger than the relief valve outlet. DO NOT INSTALL A CAP OR VALVE AT THE RELIEF VALVE OUTLET. CAUTION Pipe the discharge of the relief valve as close as possible to the floor and away from high traffic areas. Pipe the discharge close to a floor drain. Failure to do so may result in personal injury and/or property damage. CAUTION The relief valve must be mounted in a vertical upright position. No other valve or restriction is to be installed in this line. 8. Circulator: Circulators for central heating distribution should be sized and installed in accordance with system requirements and pump manufacturers recommendations. 9. Indirect Water Heater: An indirect water heater should be piped to a dedicated zone as shown in Figure Boiler Drain Valve: Fittings are provided for mounting the boiler drain valve in the return tapping at the bottom rear of the boiler. See Figure 3.4. It is recommended that the boiler return be piped to the rear of the block, however for a front return locations see Figure

10 WATER PIPING Figure 3.3: Recommended Water Piping 8

11 WATER PIPING D. FREEZE PROTECTION Glycol for hydronic applications is specially formulated for heating systems. It includes inhibitors which prevent the glycol from attacking metallic system components. Make sure that the system fluid is checked for correct glycol concentration and inhibitor level. E. SPECIAL APPLICATIONS 1. If the WBV/WV boiler is used in conjunction with a chilled medium system, pipe the chiller in a separate secondary loop as shown in Figure If using the WBV/WV with a hot water coil in a forced air system, be sure the hot water coil is downstream of the cooling coil in the airstream. F. TANKLESS HEATER OR COVERPLATE Figure 3.4: Recommended Near Boiler Piping for Rear Return 1. If a tankless coil is used (item 9), install as pictured. On water boilers, install in opening in front section. DANGER Install anti-scald device in hot water supply piping. Water temperature above 125 F can cause severe burns instantly or death from scalds. NOTICE X1019R and X1020R coils installed in WBV boilers have internal flow controls installed. Do not use external flow controls with these coils. 2. If not using a tankless coil, cover the heater opening with cover plate (item 7 or 16). NOTICE Be sure rubber gasket is in place between cover plate or water heater plate and boiler section. Figure 3.5: Optional Near Boiler Piping for Front Return C. SYSTEM PIPING 1. The WBV/WV Plastic Jacket boiler is recommended to be piped with the return line in the rear. The return can be moved to the front of the boiler by moving the plug from the front return port to the rear. The necessary componets for a front return are included with the boiler. 2. Figure 3.3 shows the recommended piping for the WBV/WV boiler. 3. The DHW zone is piped from the primary loop in parallel with the central heating (CH) zones. It should be piped as close to the boiler as possible since it should be the hottest zone. G. CONTROLS CAUTION Pipe the discharge of the safety valve or relief valve to prevent injury in the event of pressure relief. Pipe the discharge to a drain. Provide piping that is the same size as the relief valve. 1. Water Boiler Controls: a. For installations subject to UL726, a second operating control that senses water temperature is also required (not provided). Use an L4080B or equivalent. Install in the supply piping near the boiler. 2. For complete information on servicing and adjustment of controls, refer to the attached control specification sheets. 9

12 WATER PIPING Figure 3.6: WBV/WV Piped with a Chiller Figure 3.7: Tankless Coil Piping, Water Boiler 10

13 BURNER SETUP & BOILER OPERATION 4. BURNER SETUP & BOILER OPERATION CAUTION This appliance is designed to burn only standard No. 1 or No. 2 Fuel Oil (ASTM D396). Do not use gasoline or waste oil. CAUTION Do not use compression fitting for oil supply lines. Do not use copper sweat fittings with oil piping. Oil leaks may occur causing a fire hazard. NOTICE Oil piping must be air tight. Air leaking into the oil supply system may cause erratic burner operation and/or burner lockout. A. BURNER INSTALLATION 1. The oil burner is supplied with a mounting flange fixed in position. NOTICE Be sure high temperature gasket is between the burner mounting flange and the burner mounting plate. 2. Mount the burner to the burner mounting plate (Item 5 Figure 8.1) with four (4) 5/16" studs and nuts provided. 3. Pipe the oil lines through the holes in the left side of the jacket. Care must be taken when routing the oil lines so not to interfere with the opening and closing of the burner mounting plate. Flexible oil lines or flared copper disconnects with valves (when copper lines are used) may be installed to assure full opening of the burner mounting plate when servicing. NOTICE Two-pipe oil supply for Riello burner requires a separate kit. Order part #C from Riello dealer. 4. Oil burner specifications: For information pertinent to the oil burner such as nozzle sizing, fuel supply piping, adjusting or servicing, refer to the charts in this section and the burner installation manual. B. BURNER START-UP AND ADJUSTMENT 1. Burner should start automatically when thermostat is turned up and main boiler service switch is turned on. If burner does not start, check to be sure there is oil in the tank and push reset button on burner control: Beckett: Square red button. Carlin: Round red button. Riello: Round red button inside clear flexible cover on back of burner cover. If burner still does not start, contact serviceman. CAUTION Do not attempt to start the burner when excess oil has accumulated, when the unit is full of vapor, or when the combustion chamber is very hot. 2. Adjust burner and barometric draft control for highest CO ² (Maximum 13%) while maintaining a 0 Smoke and -.01 to -.02" W.C. draft overfire. All adjustments must be made using suitable instruments such as found in a Bacharach Combustion Test Kit. WARNING Do not attempt to set up the burner without using test instruments. Visual and auditory inspection can not be trusted to assure proper operation. Failure to check and adjust combustion using combustion test instruments may result in severe personal injury, death or major property damage. 3. Burner and boiler can be shut down by turning down the thermostat and moving the main boiler service switch to the "off" position. 4. See burner manufacturer s manual for further information regarding the burner. C. CHECK BOILER CONTROLS 1. Limit and Operating Controls: a. Lower the set point of each control until the burner shuts down. Note that the system pressure (or temperature) corresponds to the desired set point. b. Return the controls to the desired set point. 2. Low Water Cut-off (Built in to limit control.) - consult the manufacturer's instructions for the low water cutoff operational check procedure. 3. Refer to Limit Control Man. Instrucitons for further information. 11

14 BURNER SETUP & BOILER OPERATION D. PURGE AIR FROM THE SYSTEM (WATER BOILERS ONLY) 1. Purge the system using purge valves, isolating zones in the process or use system vents. Do not operate the pump(s) while purging. Pumps will hold air in the eye of the impeller. 2. Allow the system to reach 180 F and use manual vents, if installed, to remove any remaining air. Watch the pressure gauge as the system approaches 180 F. If the pressure exceeds the design operating pressure, check: a. Fill valve pressure. b. Expansion or compression tank operation and sizing. 12

15 Table 5.1: Boiler Model No. Beckett Burner Specifications Burner Model No. Burner Head BURNER SETUP & BOILER OPERATION BECKETT BURNER SPECIFICATIONS Static Pump Start-up Settings Nozzle Size Plate Pressure Air Shutter Air Band Head Setting WBV AFG-F3¹ F3 3-3/8" B HAGO³ 140 PSI N/A WBV AFG-F4 F4 3-3/8" B HAGO 140 PSI N/A WBV AFG-F4 F4 3-3/8" B DEL PSI N/A WBV AFG-F4 F4 3-3/8" B HAGO³ 140 PSI N/A WBV AFG-F6 F6 2-3/4" B HAGO 140 PSI N/A WV AFG-MV1 V B HAGO³ 140 PSI WV AFG-MV1 V B HAGO 140 PSI BECKETT NX BURNER SPECIFICATIONS Boiler Model No. Burner Model Nozzle Size Pump Pressure Start Up Head/Air WBV NX70LB 0.65 x 60 W DEL³ WBV NX70LB 0.85 x 60 B HAGO WBV NX70LB 0.75 x 60 W DEL WBV NX70LD 1.10 x 60 W DEL³ WBV NX70LD 1.25 x 60 W DEL Note: Burner used to fire the WBV and 1.05 rate is also required to fire the WBV rate with nozzle indicated in above chart. Table 5.2: Boiler Model No. Carlin Burner Specifications (with PSC motor) CARLIN BURNER SPECIFICATIONS (WITH PSC MOTOR) Burner Start-up Settings Head Bar Nozzle Size Pump Pressure Model No. Air Shutter Air Band WBV EZ-1HP A DEL³ 150 PSI Blank 0.60 WBV EZ-1HP A DEL 150 PSI Blank 0.65 WBV EZ-1HP A DEL PSI Blank 0.60 WBV EZ-1HP A DEL³ 150 PSI Blank 0.85 WBV EZ-1HP B DEL 150 PSI Blank 1.00 WV FRD N/A B HAGO³ 150 PSI Open 10% open WV FRD N/A B HAGO 150 PSI Open 45% open Table 5.3: Boiler Model No. Riello Burner Specifications Burner Model No. RIELLO BURNER SPECIFICATIONS Burner Series Nozzle Size² Pump Pressure Start-Up Settings Turbulator Air Damper WBV F3 Series B 145 PSI WBV F5 Series W³ 170 PSI WBV F5 Series W 165 PSI WBV F5 Series B PSI WBV F5 Series W³ 155 PSI WBV F5 Series W 160 PSI WV F10 Series B³ 165 PSI WV F10 Series B 170 PSI Factory Installed Nozzles (Packaged Boilers or Burner Cartons) are indicated in Boldface. 1 Requires Low Firing Rate Baffle 2 Delavan Recommended 3 Shipped Loose with Packaged Boiler or Burner Carton 4 Not included with Packaged Boiler or Burner Carton 13

16 ELECTRICAL 5. ELECTRICAL A. GENERAL All electrical wiring shall be done in accordance with the National Electrical Code and Local Requirements. Single pole switches including those of safety controls or protective devices shall not be wired in a grounded line. B. WIRING 1. See Section 4 for mounting burner. 2. For complete information on servicing and adjustment of controls, refer to the attached control specification sheets. 3. See the following Wiring Diagrams: Figure Water Boilers, Beckett 7600A Limit Control Figure Water Boilers, Hydrolevel 3250 Limit Control 14

17 ELECTRICAL Figure 4.1: Water Boilers, Beckett 7600A Limit Control Figure 4.1a: Beckett AquaSmart 7600A Limit Control Wiring Details 15

18 ELECTRICAL Figure 4.2: Water Boilers, Hydrolevel 3250 Limit Control Figure 4.2a: Hydrolevel HydroStat 3250 Limit Control Wiring Details 16

19 MAINTENANCE 6. MAINTENANCE WARNING Product Safety Information Refractory Ceramic Fiber Product This appliance contains materials made from refractory ceramic fibers (RCF). Airborne RCF, when inhaled, have been classified by the International Agency for Research on Cancer (IARC), as a possible carcinogen to humans. After the RCF materials have been exposed to temperatures above 1800 F, they can change into crystalline silica, which has been classified by the IARC as carcinogenic to humans. If particles become airborne during service or repair, inhalation of these particles may be hazardous to your health. Avoid Breathing Fiber Particulates and Dust Suppliers of RCF recommend the following precautions be taken when handling these materials: Precautionary Measures: Provide adequate ventilation. Wear a NIOSH/MSHA approved respirator. Wear long sleeved, loose fitting clothing and gloves to prevent skin contact. Wear eye goggles. Minimize airborne dust prior to handling and removal by water misting the material and avoiding unnecessary disturbance of materials. Wash work clothes separately from others. Rinse washer thoroughly after use. Discard RCF materials by sealing in an airtight plastic bag. First Aid Procedures: Inhalation: If breathing difficulty or irritation occurs, move to a location with fresh clean air. Seek immediate medical attention if symptoms persist. Skin Contact: Wash affected area gently with a mild soap and warm water. Seek immediate medical attention if irritation persists. Eye Contact: Flush eyes with water for 15 minutes while holding eyelids apart. Do not rub eyes. Seek immediate medical attention if irritation persists. Ingestion: Drink 1 to 2 glasses of water. Do not induce vomiting. Seek immediate medical attention. 17

20 MAINTENANCE A. GENERAL 1. Check pipes adjacent to cold walls or in unheated spaces. Insulate and tape them if necessary to be sure they can't freeze up. Keeping the water moving at all times will reduce the likelihood of freezing. 2. If there is considerable foreign matter in the boiler water, the boiler should be shut down and allowed to cool, then drained and thoroughly flushed out. Drain the boiler at the drain cock. Pipe the drain cock to a suitable drain or containment device (if antifreeze is used). Flush the system to remove remaining matter. If there is evidence that hard scale has formed on the internal surfaces, the boiler should be cleaned by chemical means as prescribed by a qualified water treatment specialist. 3. There must be no signs of continuous wetness at the chimney. If signs of continuous wetness are observed, a qualified service agency must be consulted to modify the vent configuration to prevent the formation of condensate, which may damage the vent pipe. WARNING Do not use this appliance if any part has been under water. Improper or dangerous operation may result. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any control which has been under water. B. DAILY MAINTENANCE (WITH BOILER OPERATING) Daily boiler observation can be performed by the owner. If any potential problems are found, a qualified installer or service technician/agency must be notified. 1. Remove any combustible materials, gasoline and other flammable liquids and substances that generate flammable vapors from the area where the boiler is contained. Make certain that the boiler area has ample air for combustion and ventilation and that there are no obstructions to the free flow of air to and from the boiler. 2. Observe general boiler conditions (unusual noises, vibrations, etc.) 3. Observe operating temperature and/or pressure gauge on the boiler. Boiler pressure should never be higher than 5 psi below the rating shown on the safety relief valve. The valve rating can be found on the top of the safety relief valve. Boiler temperature should never be higher than 250 F. 4. Check for water leaks in boiler and system piping. C. WEEKLY MAINTENANCE (WITH BOILER OPERATING) 1. Flush float-type low-water cut-off (if used) to remove sediment from the float bowl as stated in the manufacturer's instructions. D. MAINTENANCE OF SAFETY RELIEF VALVE 1. Check function and maintain safety relief valve as specified by manufacturer, typically every other month or every month, per the instructions on the tag on the safety relief valve. E. MONTHLY MAINTENANCE (WITH BOILER OPERATING) 1. Check boiler room floor drains for proper functioning. 2. Test probe type low-water cut-off (if used) by using the Push-to-Test Button. 3. Test limit by lowering the limit set point until the burner shuts down. When proper operation is confirmed, return the set point to original setting. 4. Follow additional instructions in the Burner Manual for proving the burner component operation. F. MAINTENANCE ANNUAL TO CLEAN: NOTICE Entire heating system, including boiler, burner and venting system, must be inspected at least once a year by a qualified heating professional. Boiler is to be cleaned at least once a year. WARNING Disconnect all power to the burner before accessing combustion chamber. 1. Remove top jacket panel and flue collector cover plate, Item 11 (Figure 2.1). 2. To thoroughly clean the boiler it must be brushed down from the top. The target wall is made of a soft ceramic fiber. Care must be taken not to damage this material during cleaning. 3. Remove any scale or soot from the combustion chamber area by vacuum cleaning or any other available means. NOTICE Burner mounting plate must be opened gain access to combustion chamber for the removal of dirt and debris. 18

21 MAINTENANCE 4. Inspect the insulation and rope seal on the burner mounting plate. Replace if damaged. 5. Replace oil burner and flue collector cover plate making sure all gaskets are in place. 6. Replace jacket top panel. NOTICE All cover plates, enclosures, and guards must be maintained in place at all times, except during maintenance and servicing. 7. Check the ventilation system for signs of external corrosion. 8. Disassemble exhaust vent and air inlet (if applicable) connections to check for blockage and/or corrosion. 9. Assure that barometric damper swings freely. G. WATERSIDE INSPECTION 1. Connect a suitable drain hose to the boiler drain valve. Have a 5 gallon bucket available to catch boiler water. 2. Be sure that the system temperature is below 125 F before draining water from the system. WARNING Water in excess of 125 F can cause severe burns instantly. DO NOT drain water in excess of 125 F from the boiler. Failure to comply may cause severe injury or death. H. INSPECT HEAT DISTRIBUTION SYSTEM 1. Check all visible water piping for signs of water leaks (corrosion scale or scale staining). 2. Check the boiler system pressure to be sure it is at the required pressure. Open the city water inlet valve to assure required system pressure (usually about 12 psi). Close the inlet valve (if it is necessary to open the inlet water valve frequently, a substantial leak may be the cause). 3 Repair any leaks to the system to prevent corrosion and scale in the boiler. I. IF A LONG SHUTDOWN IS REQUIRED 1. To take boiler out of service if the boiler and system are not to be used when temperatures are below freezing: a. Drain the boiler and system completely and shut off make-up water supply. b. Open main line power disconnect switch to boiler. Remove the fuses or secure the switch so that the power cannot be turned on accidentally. 2. Be certain that the boiler and system are refilled before returning to service. CAUTION Always keep the manual fuel supply valve shut off if the burner is shut down for an extended period of time. 3. Drain water from the boiler into the bucket. If there is evidence of excessive sediment/sludge in the system, contact a qualified water treatment company for appropriate compounds such as Sentinel X-400 or Rhomar Hydro-Solve CAUTION The Peerless Warranty does not cover sediment or corrosion related damage. Excessive sediment may cause a failure of the boilers cast iron heat exchanger. 19

22 BOILER DIMENSIONS & RATINGS 7. BOILER DIMENSIONS & RATINGS Boiler Model Number Jacket Depth "A" Jacket Width "B" Jacket Height "C" Rear of Jacket to c/l of Vent "D" Vent Size Diameter "E" WBV /085/ /8" 23-5/8" 39-1/4" 7" 6" WBV /125/ /8" 23-5/8" 39-1/4" 11" 6" WBV / /8" 23-5/8" 39-1/4" 15" 7" Figure 7.1: Boiler Dimensions, Water Boiler 20

23 BOILER DIMENSIONS & RATINGS Table 7.1: Boiler Ratings SERIES WBV/WV BOILER RATINGS - WATER Series WBV/WV - water Boiler Model Number Input Heating Capacity 4, MBH Net Ratings 3 AFUE, % Water, GPH¹ MBH Water MBH² Water WBV W WBV W WBV W WBV W WBV W WBV W WBV W WBV W Water Content, gal Minimum Stack Draft Required, in. W.C As an ENERGY STAR Partner, PB Heat, LLC has determined that these firing rates meet the ENERGY STAR guidelines for energy efficiency. Top venting only. Nozzles for these firing rates not provided as standard equipment. Consult factory for price and availability. This firing rate can only be achieved with a Riello F-3 burner. See Table Burner input based on No. 2 fuel oil with a heating value of 140,000 Btu per gallon. 2 Net water ratings based on an allowance of Consult factory before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. 4 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government tests. Chimney Size: 8" x 8" x 15 ft. 21

24 REPAIR PARTS 8. REPAIR PARTS Repair parts are available from your local PB Heat, LLC distributor or from Parts To Your Door at 1 (610) ( Note: Remember to include the boiler model number and serial number when ordering parts. Figure 8.1: Water boiler 22

25 REPAIR PARTS Table 8.1 Item No.* Part numbers may be subject to change without notice. *See Figure 8.1 boiler exploded view. Description Additional Information Stock Code Block Assembly Water WBV-03( Open) Block Assembly Water WBV-04 (Open) Block Assembly Water WV-05 (Open) Block Assembly Water WBV-03 (Closed) Block Assembly Water WBV-04 (Closed) Block Assembly Water WV-05 (Closed) Target Wall Swing Door Hinge Burner Mounting Plate Assembly Burner Mounting Plate Insulation Burner Mounting Plate Rope Seal Steel Cover Plate (Front) Water Rubber Gasket (Front) Water Tankless Coil WBV-03 Water Tankless Coil WBV-04 Water Tankless Coil WV-05 Water Flue Collector Plate Blanket Seal Flue Collector Cover Plate WBV Flue Collector Cover Plate WBV A Top Outlet Flue Collector Plate WV Rope Seal Rear Outlet Cover Plate Flue Collar Adapter WBV-03 & 04 Water Plastic Jacket Assembly Water WBV Plastic Jacket Assembly Water WBV Plastic Jacket Assembly Water WV Jacket Support Frame Upper Plastic Cover Flue Outlet Gasket PP Lower Plastic Cover Plastic Lens Drain Valve Relief Valve Water Bracket/Sensor Assembly HydroStat Insulation Hardware PJKT Limit Control, Beckett AquaSmart 7600A Immersion Well, Beckett 7600T Sensor, Beckett 7600P 07B Long Limit Control with 24" Sensor, Hydrolevel HydroStat Immersion Well, Hydrolevel

26 Series WBV/WV Plastic Jacket Oil Boilers Installation, Operation & Maintenance Manual TO THE INSTALLER: This manual is the property of the owner and must be affixed near the boiler for future reference. TO THE OWNER: This boiler should be inspected annually by a Qualified Service Agency. Service Information Name: Address: PB HEAT, LLC 131 S. CHURCH ST BALLY, PA Phone: WEB-2 (02/17) 2014 PB Heat, LLC. All rights reserved. PP8176 R0 (06/14-5M) Printed in U.S.A.

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Series Oil WBV Boilers As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Installation, Operation & Maintenance Manual TABLE

More information

WBV/WV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

WBV/WV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual Series Oil WBV/WV Boilers As an ENERGY STAR Partner, PB Heat, LLC has determined that certain firing rates of this product meet the ENERGY STAR guidelines for energy efficiency. Installation, Operation

More information

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Series Oil WBV Boilers As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Installation, Operation & Maintenance Manual TABLE

More information

WV-DV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

WV-DV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual Series Oil WV-DV Boilers Installation, Operation & Maintenance Manual NOTICE Sidewall Venting The Peerless WV-DV is designed and built to be vented through a side wall of a building using a stainless steel

More information

EC/ECT. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

EC/ECT. Series. Oil. Boilers. Installation, Operation & Maintenance Manual Series Oil EC/ECT Boilers Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. INSTALLATION CLEARANCE.............1 B. SPECIAL ATTENTION BOXES............1

More information

HWX GAS BOILERS USER S INFORMATION MANUAL

HWX GAS BOILERS USER S INFORMATION MANUAL UMHWX3-1 22-UMHWX3 HWX GAS BOILERS USER S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury

More information

GBX GAS BOILERS USER S INFORMATION MANUAL

GBX GAS BOILERS USER S INFORMATION MANUAL S-GBXUM-2 00-GBXUM GBX GAS BOILERS USER S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury

More information

WB90. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

WB90. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Series Oil WB90 Boilers As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. Installation, Operation & Maintenance Manual TABLE

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL Advantage DV GAS - FIRED BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or

More information

DOMESTIC WATER HEATER OIL FIRED

DOMESTIC WATER HEATER OIL FIRED DOMESTIC WATER HEATER OIL FIRED Models : CMO32-II CMO32-II-R CMO50-II CMO32-II & CMO32-II-R INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE

More information

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER Models SFH-3085 SFH-3100 SFH-4100 SFH-4125 SFH-4145 SFH-5160 SFH-5185 SFH-6175 SFH-6210 STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Tested For 75

More information

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER Models SFH-3085 SFH-3100 SFH-4100 SFH-4125 SFH-4145 SFH-5160 SFH-5185 SFH-6175 SFH-6210 STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Tested For 75

More information

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls... 12a Replacement parts Section assembly... 55 Base... 56 Jacket... 58 Trim... 60 Controls... 61 Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler

More information

Series. Gas/Oil Boilers Water. Oil, Gas & Installation, Operation & Maintenance Manual

Series. Gas/Oil Boilers Water. Oil, Gas & Installation, Operation & Maintenance Manual Series Oil, Gas & LC Gas/Oil Boilers Water Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL A. INSTRUCTION MANUALS............... B. SPECIAL ATTENTION

More information

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES Models BC3095 BC4100 BC4115 BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES Maximum Allowable Working Pressure 30 psi. Manufactured by: ECR

More information

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED Models: CMO32 CMO50 DNS-1102 Rev. A DNS-0413 Rev. A CMO32 CMO50 INSTALLER / SERVICE TECHNICIAN: USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF

More information

FWZ Series Oil-Fired Hot Water Boilers INSTALLATION INSTRUCTIONS

FWZ Series Oil-Fired Hot Water Boilers INSTALLATION INSTRUCTIONS D E S I G N E D T O L E A D FWZ Series Oil-Fired Hot Water Boilers INSTALLATION INSTRUCTIONS Models: FWZ060 FWZ080 FWZ100 FWZ130 FWZ160 WARNING: Improper installation, adjustment, alteration, service or

More information

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Description Model Weil-McLain part number. Vent Termination Kit for 3 Stainless Steel All Replacement parts Figure 96 Miscellaneous parts Description Model Weil-McLain part number Vent Termination Kit for 3" PVC All 383-500-397 Vent Termination Kit for 3" Stainless Steel All 382-200-430 Vent

More information

SERIES II OIL-FIRED CAST IRON HOT WATER BOILER

SERIES II OIL-FIRED CAST IRON HOT WATER BOILER Model No. UH3KW0.60 UH3KW0.75 UH3KW1.00 UH4KW0.90 UH4KW1.25 UH4KW1.50 UH5KW1.20 UH5KW1.75 UH5KW2.00 SERIES II OIL-FIRED CAST IRON HOT WATER BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Manufactured

More information

OIL-FIRED CENTRAL FURNACE

OIL-FIRED CENTRAL FURNACE OIL-FIRED CENTRAL FURNACE Installation, Operation, and Service Manual With Users Information Section Models: CSHB60-90XE CSHB60-90XP c WARNING: Do NOT store or use gasoline or other flammable vapors and

More information

OIL-FIRED CAST IRON HOT WATER BOILER. Parts and Optional Accessories

OIL-FIRED CAST IRON HOT WATER BOILER. Parts and Optional Accessories Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75 OIL-FIRED CAST IRON HOT WATER BOILER Parts and Optional Accessories EMPIRE II SERIES 3 Ordering Instructions Order Parts through your

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PRODUCT LITERATURE Lennox Industries Inc. Dallas, Texas INSTALLATION INSTRUCTIONS COWB3 OIL FIRED BOILER RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE These instructions must be affixed on or adjacent

More information

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3 OIL-FIRED Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water s Optional Tankless Coils Rear or Top Flue Convertibility Standard Equipment: Cast Iron - Factory

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline

More information

TriFire High Efficiency Oil Fired Hot Water Boiler

TriFire High Efficiency Oil Fired Hot Water Boiler Installation, operation and maintenance MANUAL Utica BOILERS P.O. Box 4729 Utica, NY 13504-4729 TriFire High Efficiency Oil Fired Hot Water Boiler An ISO 9001-2000 Certified Company MEMBER: The Hydronics

More information

SC/SCT. Series. Oil, Gas & Gas/Oil Boilers. Installation, Operation & Maintenance Manual

SC/SCT. Series. Oil, Gas & Gas/Oil Boilers. Installation, Operation & Maintenance Manual Series Oil, Gas & SC/SCT Gas/Oil Boilers Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. INSTALLATION SEQUENCE................1 B. SPECIAL ATTENTION

More information

TriFire High Efficiency Oil Fired Hot Water Boiler

TriFire High Efficiency Oil Fired Hot Water Boiler Installation, operation and maintenance MANUAL Utica BOILERS P.O. Box 4729 Utica, NY 13504-4729 TriFire High Efficiency Oil Fired Hot Water Boiler An ISO 9001-2000 Certified Company MEMBER: The Hydronics

More information

Elite. User s Information Manual. Elite and Elite VWH* All Models

Elite. User s Information Manual. Elite and Elite VWH* All Models Elite User s Information Manual Elite and Elite VWH* All Models Heat Exchanger Bears the ASME H Stamp IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING

More information

Boiler Manual. Oil-Fired Steam Boilers. Maintenance Parts. Installation Startup

Boiler Manual. Oil-Fired Steam Boilers. Maintenance Parts. Installation Startup Oil-Fired Steam Boilers Boiler Manual Installation Startup Maintenance Parts This manual must only be used by a qualified heating installer/service technician. BEFORE installing, read all instructions

More information

EUTECTIC EC-10 INSTALLATION AND OPERATING INSTRUCTIONS SERVICE COMPANY OIL-FIRED WATER BOILERS/NO. 2 OIL. Name Address. Telephone Model # Serial #

EUTECTIC EC-10 INSTALLATION AND OPERATING INSTRUCTIONS SERVICE COMPANY OIL-FIRED WATER BOILERS/NO. 2 OIL. Name Address. Telephone Model # Serial # EUTECTIC EC-10 OIL-FIRED WATER BOILERS/NO. 2 OIL INSTALLATION AND OPERATING INSTRUCTIONS SAFETY WARNING: KEEP BOILER AREA CLEAR AND FREE FROM COM- BUSTIBLE MATERIALS, GASOLINE AND OTHER FLAM- MABLE VAPORS

More information

MC Series Gas-Fired Heating Appliance

MC Series Gas-Fired Heating Appliance MC Series Gas-Fired Heating Appliance USER S INFORMATION MANUAL MC Series Models MC50 / MC80 MC99 / MC120 NOTICE: HTP reserves the right to make product changes or updates without notice and will not be

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

High Efficiency 3-Pass Oil Fired Hot Water Boiler

High Efficiency 3-Pass Oil Fired Hot Water Boiler FOR U.S. SALES ONLY This manual must be left with owner and should be hung on or adjacent to the boiler for reference. Q3 US High Efficiency 3-Pass Oil Fired Hot Water Boiler MODELS Q3-4, Q3-5, Q3-6 and

More information

EXCELSIOR. High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS

EXCELSIOR. High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS EXCELSIOR Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190 High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS Ordering Instructions

More information

SERIES PSCII GAS BOILERS

SERIES PSCII GAS BOILERS USER S INFORMATION MANUAL SERIES PSCII GAS BOILERS TO THE INSTALLER:This manual is the property of the owner and must be affixed near the boiler for future reference. TO THE OWNER: This boiler should be

More information

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water Aqua Balance WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water User s Information Manual * Low Lead Content If the information in this manual is not followed exactly, a fire

More information

Boiler Manual. Series 3 Oil-Fired Water Boiler. Maintenance Parts. Installation Startup

Boiler Manual. Series 3 Oil-Fired Water Boiler. Maintenance Parts. Installation Startup Series 3 Oil-Fired Water Boiler Boiler Manual Installation Startup Maintenance Parts This manual must only be used by a qualified heating installer/service technician. Read all instructions, including

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

XL-2000 INSTALLATION AND OPERATING INSTRUCTIONS OIL-FIRED WATER BOILERS/NO. 2 OIL SERVICE COMPANY. Name Address. Telephone Model # Serial #

XL-2000 INSTALLATION AND OPERATING INSTRUCTIONS OIL-FIRED WATER BOILERS/NO. 2 OIL SERVICE COMPANY. Name Address. Telephone Model # Serial # XL-2000 OIL-FIRED WATER BOILERS/NO. 2 OIL INSTALLATION AND OPERATING INSTRUCTIONS SAFETY WARNING: KEEP BOILER AREA CLEAR AND FREE FROM COM- BUSTIBLE MATERIALS, GASOLINE AND OTHER FLAM- MABLE VAPORS AND

More information

Columbia Boiler Company

Columbia Boiler Company EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net

More information

Universal Fire Tube Boiler Wall Mount Models

Universal Fire Tube Boiler Wall Mount Models Universal Fire Tube Boiler Wall Mount Models USER S INFORMATION MANUAL Models WBRU**80W / 100W / 120W / 140W / 175W / 199W **NG denotes Natural Gas Model, LP Denotes Propane Model Heat Exchanger Bears

More information

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190 TRIFIRE SERIES II High Efficiency Oil Fired Hot Water Boiler Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190 REPAIR PARTS & OPTIONAL KITS Ordering

More information

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09] High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS P/N# 240007518, Rev. C [01/09] JACKET 3 5 8 10 7 9 4 6 1 11 Key Description 4 section 5 section 6 section 7 section Complete Jacket

More information

EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75

EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75 EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75 OIL-FIRED CAST IRON HOT WATER BOILER Parts and Optional Accessories Ordering Instructions Order Parts through your

More information

STARFIRE V STEAM Series 5 OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL. Models

STARFIRE V STEAM Series 5 OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL. Models STARFIRE V STEAM Series 5 OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Models SFE-3090S SFE-3090ST SFE-4125S SFE-4125ST SFE-5185S SFE-5185ST SFE-6210S SFE-6210ST PATENT 7,823,544

More information

MI/MIH. Series. Gas. Boilers. Installation, Operation & Maintenance Manual

MI/MIH. Series. Gas. Boilers. Installation, Operation & Maintenance Manual Series Gas MI/MIH Boilers Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. INSTALLATION SEQUENCE.............1 B. SPECIAL ATTENTION BOXES...........1

More information

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater Contents Section Page Major Components... 2 1 About Our Manual... 2 2 Refractory Handling...

More information

FOR OIL, GAS OR COMBINATION OIL-GAS FIRING

FOR OIL, GAS OR COMBINATION OIL-GAS FIRING 1 81301R6-7/03 FOR OIL, GAS OR COMBINATION OIL-GAS FIRING Price - $00 boiler, on information seeking When contractor. heating your call boiler, to repairs or service For Label. Rating on shown as Number

More information

ESC IV STEAM SERIES 4 OIL-FIRED CAST IRON BOILER

ESC IV STEAM SERIES 4 OIL-FIRED CAST IRON BOILER ESC IV STEAM SERIES 4 OIL-FIRED CAST IRON BOILER MODELS ESC-3090S ESC-3090ST ESC-4125S ESC-4125ST ESC-5185S ESC-5185ST ESC-6210S ESC-6210ST INSTALLATION, OPERATION & MAINTENANCE MANUAL PATENT 7,823,544

More information

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190 II Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190 An ISO 9001-2008 Certified Company 2201 Dwyer Avenue, Utica NY 13501 web site: www.ecrinternational.com

More information

PEERLESS BOILER PRODUCT REVIEW

PEERLESS BOILER PRODUCT REVIEW PEERLESS Series MI/MIH II/ MI 85 PC-160 Combi Cast 92 PureFire Series PSC II Series DE Series 63 & 64 Series GM Peerless Partner PEERLESS Series WB90 Series WBV Premium Jacket Series WBV Classic Jacket

More information

TC II. Series. Oil, Gas & Gas/Oil Boilers. Installation, Operation & Maintenance Manual

TC II. Series. Oil, Gas & Gas/Oil Boilers. Installation, Operation & Maintenance Manual Series Oil, Gas & TC II Gas/Oil Boilers Installation, Operation & Maintenance Manual TABLE OF CONTENTS TABLE OF CONTENTS USING THIS MANUAL 1 A. MANUAL ORGANIZATION..............1 B. SPECIAL ATTENTION BOXES............1

More information

Boiler Manual. Oil-Fired Water Boilers. Maintenance Parts. Installation Startup

Boiler Manual. Oil-Fired Water Boilers. Maintenance Parts. Installation Startup Oil-Fired Water Boilers Boiler Manual Installation Startup Maintenance Parts This manual must only be used by a qualified heating installer/service technician. BEFORE installing, read all instructions

More information

Boiler Manual. Series 3 Oil-Fired Water Boilers. Installation Maintenance Parts

Boiler Manual. Series 3 Oil-Fired Water Boilers. Installation Maintenance Parts Series 3 Oil-Fired Water Boilers Boiler Manual Installation Maintenance Startup Parts This manual must only be used by a qualified heating installer/service technician. BEFORE installing, read all instructions

More information

Boiler Manual. Series 3 Oil-Fired Water Boilers. Installation Maintenance Parts

Boiler Manual. Series 3 Oil-Fired Water Boilers. Installation Maintenance Parts Series 3 Oil-Fired Water Boilers Boiler Manual Installation Maintenance Startup Parts This manual must only be used by a qualified heating installer/service technician. BEFORE installing, read all instructions

More information

Crown Boiler Company

Crown Boiler Company Crown Boiler Company Oil Vent Damper Supplemental Installation Instructions Converts Select TWZ Series Boilers to High Efficiency TWD Series Boilers These supplemental installation instructions are to

More information

GENERAL INSTALLATION AND MAINTENANCE MANUAL

GENERAL INSTALLATION AND MAINTENANCE MANUAL POST THESE INSTRUCTIONS WITH YOUR PRODUCT Model No.: Serial No.: Oil Gas/Oil Gas GENERAL INSTALLATION AND MAINTENANCE MANUAL TURBOPOWER, MAXIM WATER HEATERS (Gas, Oil and Combination Gas/Oil) and STORAGE

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-Fired Water Boilers With or without Aqua Logic (CWH) Now available Matching High Performance Companion Water Heater (Unit sold separately) If the information in this manual

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

Do not use this vent pipe or fittings for venting incinerators of any kind.

Do not use this vent pipe or fittings for venting incinerators of any kind. ! CAUTION! Do not use this vent pipe or fittings for venting incinerators of any kind. C.S.A. Certified For Natural Gas Or Propane Tested For 100 LBS. ASME Working Pressure For correct installation of

More information

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual Peerless Indirect-Fired Partner Water Heater Installation, Operation & Maintenance Manual Product Selection 1. The following guidelines apply to residential systems only. For commercial or institutional

More information

Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190

Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190 Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190 Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

Oil-Fired Hot Water Boilers Installation Instructions These instructions must be affixed on or adjacent to the boiler

Oil-Fired Hot Water Boilers Installation Instructions These instructions must be affixed on or adjacent to the boiler D E S I G N E D T O L E A D FWZ Series Oil-Fired Hot Water Boilers Installation Instructions These instructions must be affixed on or adjacent to the boiler Models: FWZ060 FWZ080 FWZ100 FWZ130 FWZ160 Warning:

More information

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils OIL-FIRED Series Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water s Optional Tankless Coils Standard Equipment: Cast Iron Sections - Factory Tested and

More information

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO. GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO. GBI 201-5 3C For a proper installation and in order to receive the best in operating life and efficiency from your

More information

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Gas Fired Residential Combi Boiler Floor and Wall Mount Models Gas Fired Residential Combi Boiler Floor and Wall Mount Models USER S INFORMATION MANUAL Models WBRC**140W WBRC**199W WBRC**140F WBRC**199F ** NG Refers to Natural Gas Operation LP Refers to Propane Gas

More information

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS CL SERIES CAST IRON OIL-FIRED BOILER

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS CL SERIES CAST IRON OIL-FIRED BOILER INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS CL SERIES CAST IRON OIL-FIRED BOILER 9700609 For service or repairs to boiler, call your heating contractor. When seeking information on boiler, provide

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MODEL NUMBERS: KSB0365, KSB3100, KSB4125, KSB4150, KSB5175, KSB5200, KSB6225, KSB7275 PENNCO BOILERS 85 Middle Rd. Dunkirk, NY 14048 Ph: (716) 366-5500 Fax:

More information

User s Information Manual

User s Information Manual User s Information Manual Series 2 Models 1000-2000 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing

More information

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section SPECIFICATION SHEETS Steam Sample Specification Water Sample Specification MOHICAN SPECIFICATION SHEET The following sample specifications are provided by Superior Boiler Works to assist you in providing

More information

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: UL 391 CAN/CSA B366.1 Unit Serial # Purchased From Company Address Name of Installer Installer Telephone # Date Installed IMPORTANT This manual must be

More information

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 19A. mith PRESSURIZED WET BASE SERIES 19A mith series19a BOILER/BURNER PRESSURIZED WET BASE UNIT series 19A STANDARD EQUIPMENT All s Cast iron wet-base sections tested for 80psi. Insulated metal jacket Cast iron smokehood with integral

More information

User s Information Manual

User s Information Manual User s Information Manual Series 3 Models 550 and 750 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing

More information

Pump or Manifold Pressure. Nozzle or Gas Orifice Size. Air Setting

Pump or Manifold Pressure. Nozzle or Gas Orifice Size. Air Setting FP Series s BECKETT OEM OIL BURNER CONFIGURATION Burner Model ATC Head Type Head setting/ firing pin Nozzle or Gas Orifice Size Air Pump or Manifold Pressure Baffle Solenoid Valve Flange Flange Insertion

More information

CER Series 2. Installation Instructions. Electric-Hydronic Boilers. Installer

CER Series 2. Installation Instructions. Electric-Hydronic Boilers. Installer CER Series 2 Electric-Hydronic Boilers Installation Instructions Installer Read all instructions before installing. Follow all instructions in proper order to prevent personal injury or death. Consider

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL SL SERIES BOILERS (Natural Gas or Propane) : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. Do not

More information

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists. gas-fired water boiler Manual Replacement parts Replacement parts must be purchased through a local Weil-McLain distributor. When ordering, specify boiler model and size and include description and part

More information

Oil-Fired Steam Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler WARNING

Oil-Fired Steam Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler WARNING D E S I G N E D T O L E A D FSZ Series Oil-Fired Steam Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler WARNING Improper installation, adjustment, alteration,

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

Single stage operation oil burner

Single stage operation oil burner Installation & Operating Manual Single stage operation oil burner WARNING NON-RETROFIT APPLICATIONS If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow

More information

APEX CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

APEX CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER USER'S INFORMATION MANUAL APEX CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal

More information

User s Information Manual

User s Information Manual User s Information Manual Gas-fired water boilers Series 4 Featuring Flexibility Series 4 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage,

More information

User s Information Manual

User s Information Manual User s Information Manual CONDENSING GAS BOILER 220/299/300/399 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA SERVICE FACTS Gas Furnaces Upflow & Downflow Induced Draft Stage Heat Models: M80P00AU2AA M80P060AU2AA M80P060AU36AA M80P080BU36AA M80P080BU8AA M80P00BU36AA M80P00CU8AA M80P00CU60AA M80PDU60AA M80P0DU60AA

More information

User s Information Manual

User s Information Manual TM User s Information Manual Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury

More information

Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER USER'S INFORMATION MANUAL Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,

More information

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation Owner s Guide Installation & Operation Hot Top HHT Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002130 REV 1 IMPORTANT

More information

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559

More information

WHAT TO DO IF YOU SMELL GAS

WHAT TO DO IF YOU SMELL GAS AHE AHE SERIES 4 Direct Vent Wall-Mounted Boilers User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

Service Instructions for use by heating contractor VITOROND 200 IMPORTANT. Read and save these instructions for future reference.

Service Instructions for use by heating contractor VITOROND 200 IMPORTANT. Read and save these instructions for future reference. Instructions for use by heating contractor Vitorond 200 VD2 Series Oil-/Gas-fired boiler Heating input: 1255 to 4387 MBH (368 to 1285 kw) VITOROND 200 Product may not be exactly as shown IMPORTANT Read

More information

Odyssey Model Numbers: CT Version Date:

Odyssey Model Numbers: CT Version Date: Odyssey Model Numbers: CT80-250 Version Date: 2017-12-08 NEW OUTDOOR SENSOR Meets Sept. 2012 requirements for Automatic Means INSTALLATION AND OPERATION INSTRUCTIONS ODYSSEY OIL BOILER Venting Applications:

More information

Installation and service must be performed by a qualified service installer, service agency or the gas supplier.

Installation and service must be performed by a qualified service installer, service agency or the gas supplier. INSTALLATION & MAINTENANCE MANUAL PRIMERA HOT WATER SUPPLY BOILER MODELS: 400B, 540B, 750B, 1000B, 1200B, 1600B & 2000B PRIMERA WATER HEATER MODELS: 400W, 540W, 750W, 1000W, 1200W, 1600W & 2000W Installation

More information

Contents. Hazard definitions

Contents. Hazard definitions GWS-090E Gas-Fired Water Boiler Boiler Manual Contents Page 1 Prepare boiler location...2 2 Prepare boiler...8 3 Install water piping...9 4 Venting and combustion air...12 5 Gas piping...12 6 Field wiring...13

More information