INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioner

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioner"

Transcription

1 Product Family: R4A3, WA3**4 These instructions must be read and understood completely before attempting installation. DANGER, WARNING, AUTION, and NOTE The signal words DANGER, WARNING, AUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING, AUTION, and NOTE will be used on product labels and throughout this manual and other manuals that may apply to the product. DANGER - Immediate hazards which will result in severe personal injury or death. WARNING - Hazards or unsafe practices which could result in severe personal injury or death. AUTION - Hazards or unsafe practices which may result in minor personal injury or product or property damage. NOTE - Used to highlight suggestions which will result in enhanced installation, reliability, or operation. Safety Labeling and Signal Words Signal Words in Manuals The signal word WARNING is used throughout this manual in the following manner: WARNING! WARNING The signal word AUTION is used throughout this manual in the following manner:! AUTION Signal Words on Product Labeling Signal words are used in combination with colors and/or pictures on product labels. TABLE OF ONTENTS Inspect New Unit Safety onsiderations Location learances Unit Support Refrigeration System Electrical Wiring Start-up Procedure Refrigerant harge Sequence of Operation Maintenance R-410A Quick Reference Guide ! WARNING DEATH, PERSONAL INJURY, AND/OR PROPERTY DAMAGE HAZARD Failure to carefully read and follow this warning could result in equipment malfunction, property damage, personal injury and/or death. Installation or repairs made by unqualified persons could result in equipment malfunction, property damage, personal injury and/or death. The information contained in this manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments. Installation must conform with local building codes and with the National Electrical ode NFPA70 current edition or anadian Electrical ode Part 1 SA April 2008

2 INSPET NEW UNIT After uncrating unit, inspect thoroughly for hidden damage. If damage is found, notify the transportation SAFETY ONSIDERATIONS onsult a qualified installer, service agency, or the dealer/distributor for information and assistance. The qualified installer must use factory authorized kits and accessories when modifying this product. Refer to the individual instructions packaged with the kit or accessory when installing. The weight of the product requires careful and proper handling procedures when lifting or moving to avoid personal injury. Use care to avoid contact with sharp or pointed edges. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use a heat sinking material - such as a wet rag - during brazing operations. Keep a fire extinguisher available. onsult local codes and the National Electric ode (NE) for special requirements. Improper installation, adjustment, alteration, service or maintenance can void the warranty. company immediately and file a concealed damage claim.! WARNING ELETRIAL SHOK HAZARD Failure to turn off the main (remote) electrical disconnect device could result in personal injury or death. Before installing, modifying or servicing system, turn OFF the main (remote) electrical disconnect device. There may be more than one disconnect device.! AUTION PROPERTY DAMAGE HAZARD Failure to follow this caution may result in property damage R-410A systems operate at higher pressures than R-22 systems. When working with R-410A systems, use only service equipment and replacement components specifically rated or approved for R-410A service. LOATION heck local codes for regulations concerning zoning, noise, platforms, and other issues. Locate unit away from fresh air intakes, vents, or bedroom windows. Noise may carry into the openings and disturb people inside. Locate unit in a well drained area, or support unit high enough so that water runoff will not enter the unit. Locate unit away from areas where heat, lint, or exhaust fumes will be discharged onto unit (as from dryer vents). LEARANES Nominal minimum clearances are 48 inches above unit for discharge air and 18 inches on each side of the coil for intake air. learance on any one side of the coil (normally between unit and structure) may be reduced to 6 inches. Nominal minimum clearances are based on a solid parallel object such as a wall or roof overhang. The clearance may be reduced for a single object with small surface area, such as the end of a wall, outside corner of a wall, fence section, post, etc. As a general rule, the minimum clearance from the unit should equal the width of the object. For example, a 6 inch fence post should be a minimum of 6 inches from the unit. Do not install unit under roof overhangs unless gutters are present. A minimum vertical clearance of 48 inches is required to the overhang. Locate unit away from recessed or confined areas where recirculation of discharge air may occur (refer to LEARANES section of this document). Roof-top installation is acceptable providing the roof will support the unit and provisions are made for water drainage and noise/vibration dampening. NOTE: Roof mounted units exposed to wind may require wind baffles. onsult the manufacturer for additional information. Inside corner locations on single story structures require evaluation. Large overhanging soffits may cause air recirculation in a corner area even though recommended minimum clearances are maintained. As a guide, locate the unit far enough out so that half of the discharge grille is out from under the soffit. When placing two or more units side-by-side, provide a minimum of 18 inches between units. Provide minimum service clearance of 24 inches from control box corner and side service panel. Refer to Figure

3 Figure 1 learances (various examples) Wall 6 Wall 6 Wall Wall Wall wide fence 6 Post 6 Wall

4 UNIT SUPPORT NOTE: Unit must be level 2 degrees ( inch rise or fall per foot of run) or compressor may not function properly. A. GROUND LEVEL INSTALLATION The unit must be level and supported above grade by beams, platform, or a pad. Platform or pad can be of open or solid construction but should be of permanent materials such as concrete, bricks, blocks, steel, or pressure- treated timbers approved for ground contact. Soil conditions must be considered so that the platform or pad does not shift or settle and leave the unit partially supported. Minimum pad dimensions are shown in Figure 2. If beams or an open platform are used for support, it is recommended that the soil be treated or area be graveled to reduce the growth of grasses and weeds. To minimize vibration or noise transmission, it is recommended that supports not be in contact with the building structure. However, slabs on grade constructions with an extended pad are normally acceptable. B. ROOF TOP INSTALLATION This type of installation is not recommended on wood frame structures where low noise levels are required. Supporting structure or platform for the unit must be level. If installation is on a flat roof, locate unit minimum 6 inches above roof level. Place the unit over one or more load bearing walls. If there are several units, mount them on platforms that are self-supporting and span several load bearing walls. These suggestions are to minimize noise and vibration transmission through the structure. If the structure is a home or apartment, avoid locating the unit over bedrooms or study. NOTE: When unit is to be installed on a bonded guaranteed roof, a release must be obtained from the building owner to free the installer from all liabilities.. FASTENING UNIT DOWN If conditions or local codes require the unit be attached in place, remove the knockouts in the base pan and install tie down bolts through the holes (refer to Figure 2). ontact local distributor for hurricane hold-down details and the P.E. (Professional Engineer) certification, when required. REFRIGERATION SYSTEM A. OMPONENT MATHES heck to see that the proper system components are in place, especially the indoor coil. R-410A outdoor units can only be used with R-410A specific indoor coils. If there is a refrigerant mis-match, consult the indoor coil manufacturer to determine if a refrigerant conversion kit is available for the indoor coil. This outdoor unit is designed for use only with indoor coils that utilize a TXV refrigerant metering device. If any other type of metering device is installed on the indoor coil, consult the indoor coil manufacturer to determine if a TXV conversion kit is available.! AUTION PROPERTY DAMAGE HAZARD Failure to follow this caution may result in property damage. Inadequate unit support may cause excessive vibration, noise, and/or stress on the refrigerant lines, leading to refrigerant line failure. Figure 2 dia. Tie Down Knockouts In Base Pan (2 places) A Base Pan (Square) Width x Depth (inches) Base Pan Width Tie Down Knockouts Tie Down Knockouts A B Representative View From Top Product Family: R series B Base Pan Depth Minimum Mounting Pad Dimensions! AUTION PRODUT DAMAGE HAZARD Failure to follow this caution may result in product damage. Indoor coil and outdoor unit must be listed as a certified combination (match) in the ARI Unitary Directory of ertified Products. Indoor coil must have R-410A specific, hard shutoff TXV refrigerant metering device. When installing a TXV on an indoor coil, follow the instructions provided with the new TXV

5 A typical TXV installation is shown in Figure 3. Figure 3 EQUALIZER TUBE SENSING BULB TXV SENSING BULB (EITHER SIDE) ÉÉ Typical TXV Installation SUTION TUBE INDOOR OIL ÉÉ SUTION TUBE LIQUID TUBE STRAP 8 O'LOK 4 O'LOK B. REFRIGERANT LINE SETS The refrigerant line set must be properly sized to assure maximum efficiency and proper oil circulation. Refer to Product Specifications and Long Line Applications Guideline for line set sizing. NOTE: Total line set length must not exceed 200 feet. A crankcase heater must be used when the refrigerant line length exceeds 80 feet. If outdoor unit is more than 10 feet higher than the indoor coil, refer to the Extended Length Refrigeration Piping Manual for instructions. When the outdoor unit is higher than the indoor coil, the vertical separation must not exceed 100 feet. When the outdoor unit is lower than the indoor coil, the vertical separation must not exceed 50 feet. If it is necessary to add refrigerant line in the field, use dehydrated or dry, sealed, deoxidized, copper refrigeration tubing. Do not use copper water pipe. Do not remove rubber plugs or caps from copper tubing until connections are ready to be made. Be extra careful when bending refrigeration tubing. Tubing can kink easily, and if this occurs, the entire length of tubing must be replaced.! WARNING PERSONAL INJURY HAZARD Failure to relieve system pressure could result in personal injury and/or death. Relieve pressure and recover all refrigerant before servicing existing equipment, and before final unit disposal. Use all service ports and open all flowcontrol devices, including solenoid valves.. ROUTING AND SUSPENDING REFRIGERANT LINES Run refrigerant lines as straight and direct as possible, avoiding unnecessary bends and turns. Always insulate the entire suction line. Both lines should be insulated when routed through an attic or when routed through an underground raceway. When routing refrigerant lines through a foundation or wall, do not allow refrigerant lines to come in direct contact with the building structure. Make openings large enough so that lines can be wrapped with extra insulation. Fill all gaps with RTV caulk. This will prevent noise transmission between the tubing and the foundation or wall. Along floor or ceiling joists, suspend refrigerant lines so that they do not contact the building structure, water pipes, or ductwork. Use insulated or suspension type hangers. Metal straps must be at least 1 wide to avoid cutting into the tube insulation. Keep the liquid and suction lines separate. Refer to Figure 4.! AUTION UNIT OPERATION HAZARD Failure to follow this caution may result in improper product operation. Do not leave system open to atmosphere any longer than absolutely required for installation. Internal system components - especially refrigerant oils - are extremely susceptible to moisture contamination. Keep ends of tubing sealed during installation until the last possible moment

6 Figure 4 Routing and Suspending Refrigerant Lines OUTDOOR WALL AULK INDOOR WALL LIQUID TUBE HANGER STRAP (AROUND SUTION TUBE ONLY) JOIST INSULATION SUTION TUBE INSULATION THROUGH THE WALL SUTION TUBE 1 MIN SUSPENSION LIQUID TUBE! AUTION UNIT OPERATION HAZARD Failure to follow this caution may result in improper product operation. Do not bury more than 36 of line set underground. Refrigerant may migrate to cooler buried section during extended periods of unit shut-down, causing refrigerant slugging and possible compressor damage at start-up. If ANY section of the line set is buried underground, provide a minimum 6 vertical rise at the service valve. D. OUTDOOR UNIT HIGHER THAN INDOOR UNIT Proper oil return to the compressor should be maintained with suction gas velocity. If velocities drop below 1500 fpm (feet per minute), oil return will be decreased. To maintain suction gas velocity, do not upsize vertical suction risers. E. LIQUID LINE FILTER-DRIER NOTE: It is recommended that an appropriate filter-drier be installed in the liquid line. Leave the plugs in the tube ends until the filter-drier is installed. The optimal location for the filter-drier is close to the indoor coil. Install the filter-drier with the arrow pointing towards the indoor coil. Refer to Figure 5. Figure 5 Liquid Line Filter-Drier Installed at Indoor oil Filter-Drier (arrow points towards indoor coil) F. SERVIE VALVES valves are closed and tube stubs are plugged from the factory. Outdoor units are shipped with a refrigerant charge sealed in the unit. Leave the service valves closed until all other refrigerant system work is complete or the charge will be lost. Leave the plugs in place until line set tubing is ready to be inserted. valve bodies are brass and tube stubs are copper

7 G. BRAZING ONNETIONS! WARNING FIRE HAZARD Failure to remove refrigerant and oil charge before brazing could result in personal injury, death, and/ or property damage. Refrigerant and oil mixture could ignite and burn as it escapes and contacts brazing torch. Make sure the refrigerant charge is properly removed from both the high and low sides of the system before brazing any component or lines. lean line set tube ends with emery cloth or steel brush. Remove any grit or debris. Insert line set tube ends into service valve tube stubs. Apply heat absorbing paste or heat sink product between service valve and joint. Wrap service valves with a heat sinking material such as a wet cloth. Braze joints using a Sil-Fos or Phos-copper alloy.! AUTION PRODUT DAMAGE HAZARD Failure to follow this caution may result in product damage. Braze with Sil-Fos or Phos-copper alloy on copper-to-copper joints and wrap a wet cloth around rear of fitting to prevent damage to TXV. H. EVAUATING LINE SET AND INDOOR OIL The unit is shipped with a factory refrigerant charge. The liquid line and suction line service valves have been closed after final testing at the factory. Do not disturb these valves until the line set and indoor coil have been evacuated and leak checked, or the charge in the unit may be lost. NOTE: Do not use any portion of the factory charge for purging or leak testing. The factory charge is for filling the system only after a complete evacuation and leak check has been performed.! AUTION PRODUT DAMAGE HAZARD Failure to follow this caution may result in product damage. Never use the outdoor unit compressor as a vacuum pump. Doing so may damage the compressor. Line set and indoor coil should be evacuated using the recommended deep vacuum method of 500 microns. If deep vacuum equipment is not available, the alternate triple evacuation method may be used by following the specified procedure. If vacuum must be interrupted during the evacuation procedure, always break vacuum with dry nitrogen. Deep Vacuum Method The deep vacuum method requires a vacuum pump capable of pulling a vacuum to 500 microns and a vacuum gauge capable of accurately measuring this vacuum level. The deep vacuum method is the most positive way of assuring a system is free of air and water. Watch the vacuum gauge as the system is pulling down. The response of the gauge is an indicator of the condition of the system (refer to Figure 6). With no leaks in the system, allow the vacuum pump to run for 30 minutes minimum at the deep vacuum level. MIRONS Figure Deep Vacuum Gauge Response and System onditions LEAK IN SYSTEM MINUTES VAUUM TIGHT TOO WET TIGHT DRY SYSTEM Triple Evacuation Method The triple evacuation method should only be used when system does not contain any water in liquid form and vacuum pump is only capable of pulling down to 28 inches of mercury. Refer to Fig. 7 and proceed is as follows: 1. Pull system down to 28 inches of mercury and allow pump to continue operating for an additional 15 minutes. 2. lose manifold valves or valve at vacuum pump and shut off vacuum pump. 3. onnect a nitrogen cylinder and regulator to system and fill with nitrogen until system pressure is 2 psig. 4. lose nitrogen valve and allow system to stand for 1 hour. During this time, dry nitrogen will diffuse throughout the system absorbing moisture. 5. Repeat this procedure as indicated in Figure

8 6. After the final evacuate sequence, confirm there are no leaks in the system. If a leak is found, repeat the entire process after repair is made. Figure 7 Triple Evacuation Sequence EVAUATE BREAK VAUUM WITH DRY NITROGEN WAIT EVAUATE BREAK VAUUM WITH DRY NITROGEN WAIT EVAUATE HEK FOR TIGHT, DRY SYSTEM (IF IT HOLDS DEEP VAUUM) HARGE SYSTEM I. OPENING SERVIE VALVES Outdoor units are shipped with a refrigerant charge sealed in the unit. Opening the service valves releases this charge into the system. NOTE: Open the Suction service valve first. If the Liquid service valve is opened first, oil from the compressor may be drawn into the indoor coil TXV, restricting refrigerant flow and affecting operation of the system. Remove Suction service valve cap and insert a hex wrench into the valve stem. Hold the valve body steady with an end-wrench and back out the stem by turning the hex wrench counterclockwise. Turn the stem until it just contacts the rolled lip of the valve body. After the refrigerant charge has bled into the system, open the Liquid service valve. NOTE: These are not back-seating valves. It is not necessary to force the stem tightly against the rolled lip. The service valve cap is a primary seal for the valve and must be properly tightened to prevent leaks. Make sure cap is clean and apply refrigerant oil to threads and sealing surface on inside of cap. Tighten cap finger tight and then tighten additional of a turn (1 wrench flat) to properly seat the sealing surfaces. J. GAUGE PORTS heck for leaks at the schrader ports and tighten valve cores if necessary. Install plastic caps finger tight. ELETRIAL WIRING! WARNING ELETRIAL SHOK HAZARD Failure to turn off the main (remote) electrical disconnect device could result in personal injury or death. Before installing, modifying or servicing system, turn OFF the main (remote) electrical disconnect device. There may be more than one disconnect device. The supply voltage must be 208/230 volts (197 volt minimum to 253 volts maximum) 60 Hz single phase. Outdoor units are approved for use with copper conductors only. Do not use aluminum wire. Refer to unit rating plate for minimum circuit ampacity and circuit protection requirements. Grounding Permanently ground unit in accordance with the National Electrical ode and local codes or ordinances. Use a copper conductor of the correct size from the grounding lug in control box to a grounded connection in the service panel or a properly driven and electrically grounded ground rod. Wiring onnections Make all outdoor electrical supply (Line Voltage) connections with raintight conduit and fittings. Most codes require a disconnect switch outdoors within sight of the unit. onsult local codes for special requirements. Route electrical supply (Line Voltage) wiring through knockout hole in bottom of ontrol Box. onnect wires to ontactor and Ground Lug according to Wiring Diagram on unit. Refer to Figure 8. Route thermostat wiring through rubber grommet in bottom of ontrol Box. Low voltage lead wires are provided in the control box for connection to thermostat wires (use wire nuts). Refer to Wiring Diagram on unit and Figure 9 for low voltage wiring examples. NOTE: Use No. 18 AWG (American Wire Gage) color-coded, insulated (35 minimum) wire. If thermostat is located more than 100 feet (30.5 m) from unit as measured along the control voltage wires, use No. 16 AWG color-coded wires to avoid excessive voltage drop. NOTE: Some models are factory equipped with omfort Alert Diagnostics device. If omfort Alert is used as a field installed option, then a hot bundle must be run for proper connection

9 Figure 8 Electrical Supply (Line Voltage) onnections DISONNET PER NE AND/OR LOAL ODES FIELD POWER WIRING FIELD GROUND WIRING L1 L2 GROUND LUG ONTATOR or 13 Figure 9 Typical Thermostat onnections THERMOSTAT FURNAE AIR ONDITIONER 24 VA HOT R R 24 VA OM HEAT STAGE 1 W/W1 W OOL STAGE 1 Y/Y2 Y INDOOR FAN G G THERMOSTAT FAN OIL AIR ONDITIONER 24 VA HOT R R 24 VA OM HEAT STAGE 1 W/W1 W2 OOL STAGE 1 Y/Y2 Y INDOOR FAN G G

10 START-UP PROEDURE 1. Set indoor thermostat selector switch to OFF. 2. Turn ON all electrical disconnect devices. 3. If unit has a crankcase heater, energize the heater and wait 24 hours before proceeding. REFRIGERANT HARGE Outdoor units are shipped with a refrigerant charge to match a specific indoor coil and 15 feet of refrigerant line. If shorter or longer refrigerant lines or a different indoor coil are used, the charge will have to be adjusted. For different line lengths, add or remove charge based on 0.6 ounces charge per foot of difference. For example, a 25 foot line set is 10 feet longer than the specified 15 feet. Add 0.6 ounces charge for each of the extra 10 feet: 10 x 0.6 = 6.0 ounces additional charge This outdoor unit is designed for use only with indoor coils that utilize a TXV refrigerant metering device. With an indoor TXV, use the subcooling method to make final charge adjustments: NOTE: Only use subcooling charging method when outdoor ambient temperature is between 70 F and 100 F indoor temperature is between 70 and 80 F line set is less that 80 feet. 1. Operate unit a minimum of 15 minutes before checking charge. NOTE: If outdoor unit has a 2-speed fan motor, motor will operate in low speed when outdoor ambient temperature is below 82 F. Pull one of the yellow low voltage wires off the fan control and the unit will default to high speed fan for servicing. Reconnect wire after servicing. 2. Measure liquid service valve pressure by attaching an accurate gauge to service port. 3. Measure liquid line temperature by attaching an accurate thermistor type sensor or electronic thermometer to liquid line near outdoor coil. 4. Set indoor thermostat at desired temperature. Be sure setpoint is below indoor ambient temperature or thermostat will not call for cooling. 5. Set indoor thermostat selector switch to OOL. Operate unit for minimum 15 minutes, then check the system refrigerant charge. 4. Refer to unit rating plate for required subcooling temperature. 5. Refer to Figure 10. Find the required liquid line temperature where the rating plate subcooling temperature intersects measured liquid service valve pressure. 6. If the measured liquid line temperature is higher than the chart number, add refrigerant to lower the measured temperature. NOTE: When adding refrigerant, charge in liquid form, using a flow restricting device, into the suction port. If the measured liquid line temperature is lower than the chart number, reclaim refrigerant to raise the measured temperature. Tolerance is 3 F. Figure 10 Measured Liquid Pressure (psig) Rating Plate (required) Subcooling Temperature ( F) R-410A Required Liquid Line Temperature ( F) Rating Plate (required) Subcooling Temperature ( F) Measured Liquid Pressure (psig)

11 SEQUENE OF OPERATION With power supplied to indoor and outdoor units, transformer is energized. On a call for cooling, the thermostat makes circuits R-Y and R-G. ircuit R-Y energizes contactor, starting outdoor fan motor and compressor. ircuit R-G energizes indoor unit blower relay, starting indoor blower motor. When thermostat is satisfied, its contacts open, de-energizing contactor and blower relay. ompressor and motors stop. NOTE: If indoor unit is equipped with a time-delay relay circuit, the blower runs an additional length of time to increase system efficiency. MAINTENANE NOTE: The RED (R) low voltage lead wire is provided only for powering the omfort Alert device. To utilize the omfort Alert device, connect the RED (R) low voltage lead wire directly to 24 VA hot at the indoor unit or thermostat. Use one of the spare wires in the thermostat cable to bring 24 VA hot out to the outdoor unit. If there are no spare wires in the thermostat cable, leave the insulation on the end of the RED low voltage lead wire to avoid an electrical short. The air conditioner will function normally without the RED (R) low voltage lead wire connected. The omfort Alert device operates by monitoring the compressor power leads and the thermostat demand signal (Y terminal). It draws constant 24 VA power at the R and terminals. ondensate Drain During the cooling season, check monthly for free flow of drainage and clean if necessary. leanliness These tips will help keep the air conditioner looking better and working more efficiently: 1. Free flow of air is essential. Keep fences, shrubs, trash cans, and other obstructions at least 18 inches from all coil inlets. 2. Keep the coil free of grass clippings, leaves, weeds, and other debris. NOTE: oil may occasionally require cleaning with a liquid solution. The coil must be cold when cleaning. Use an alkaline based cleaner only. leaning a hot coil or using an acid based cleaner will remove the paint from the fins and may clog the coil. 3. Never use a weather cover over the outdoor unit unless it is a ventilated type or made of breathable fabric that will allow moisture to evaporate rapidly. A cover that holds moisture in the unit will cause more rust build-up and damage than normal exposure to weather

12 R-410A QUIK REFERENE GUIDE R-410A refrigerant operates at 50% - 70% higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with R-410A. R-410A refrigerant cylinders are rose colored. Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400. R-410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose. Manifold sets should be 750 psig high-side and 200 psig low-side with 520 psig low-side retard. Use hoses with 750 psig service pressure rating. Leak detectors should be designed to detect HF refrigerant. R-410A, as with other HF refrigerants, is only compatible with POE oils. Vacuum pumps will not remove moisture from oil. Do not use liquid line filter-driers with rated working pressures less than 600 psig. Do not install a suction line filter-drier in liquid line. POE oils absorb moisture rapidly. Do not expose oil to atmosphere. POE oils may cause damage to certain plastics and roofing materials. Wrap all filter-driers and service valves with wet cloth when brazing. A liquid line filter-drier is required on every unit. Do not use with an R-22 TXV. If indoor unit is equipped with an R-22 TXV, it must be changed to an R-410A TXV. Never open system to atmosphere while it is under a vacuum. When system must be opened for service, break vacuum with dry nitrogen and replace all filter-driers. Do not vent R-410A into the atmosphere. Do not use capillary tube indoor coils. Observe all WARNINGS, AUTIONS, NOTES, and bold text. International omfort Products, LL 12 Lewisburg, TN

INSTALLATION INSTRUCTIONS R 22 or R 407C Air Conditioner Outdoor Component

INSTALLATION INSTRUCTIONS R 22 or R 407C Air Conditioner Outdoor Component R 22 or R 407 Air onditioner Outdoor omponent R2A3**GKR, R2A3**GHR, R2A3**GLR, R2A3**AKR, R2A3**AHR These instructions must be read and understood completely before attempting installation. IMPORTANT:

More information

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioner N4A3, C4A3, H4A3, T4A3, NXA6, CXA6, HXA6, TXA6

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioner N4A3, C4A3, H4A3, T4A3, NXA6, CXA6, HXA6, TXA6 N4A3, 4A3, H4A3, T4A3, NXA6, XA6, HXA6, TXA6 These instructions must be read and understood completely before attempting installation. DANGER, WARNING, AUTION, and NOTE The signal words DANGER, WARNING,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS R-410A Two-Stage Split System Air Conditioner Product Family: H4A6, C4A6, T4A6 H4A8, C4A8, T4A8 These instructions must be read and understood completely before attempting installation. DANGER, WARNING,

More information

Safety Labeling and Signal Words

Safety Labeling and Signal Words Theseinstructionsmust bereadand understoodcompletelybeforeattemptinginstallation. DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard

More information

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioners

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioners INSTALLATION INSTRUTIONS R 410A Split System Air onditioners NXA5, R4A5, WA5 These instructions must be read and understood completely before attempting installation. SAFETY ONSIDERATIONS Improper installation,

More information

Safety Labeling and Signal Words

Safety Labeling and Signal Words These instructions must be read and understood completely before attempting installation. DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels

More information

Installation Instructions

Installation Instructions PA13NA; PA14N; PA15N; PA16NW SPLIT -SYSTEM AIR ONDITIONER WITH R-410A REFRIGERANT 1-1/2-5 TONS Installation Instructions SAFETY ONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

Installation Instructions

Installation Instructions A13NA 018---060 A16NA 018---030 Baset Series Air onditioners with Puronr Refrigerant Installation Instructions SAFETY ONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

Installation Instructions

Installation Instructions 24AAA5, 24AAA6 24ABB3, 24AB6 24AA4, 24A4 Single---Stage omfort Series Air onditioners with Puronr Refrigerant 1---1/2 To 5 Nominal Tons (Sizes 18 to 60) Installation Instructions SAFETY ONSIDERATIONS Improper

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 3 Phase, 410A Split System Air onditioner Product Family: N4A3, H4A3 These instructions must be read and understood completely before attempting installation. DANGE, WANING, AUTION, and NOTE The signal

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Installation Instructions

Installation Instructions Installation Instructions For R410-A Refrigerant SPLIT SYSTEM Premium Line AC CONDENSERS Save This Manual for Future Reference 421 01 3204 03 Dec. 2004 I Installation Instructions R410-A Split System Condensers

More information

Installation Instructions

Installation Instructions 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,

More information

Installation Instructions

Installation Instructions Baset Series Heat Pumps with Puronr Refrigerant 1---1/2 To 5 Nominal Tons (Sizes 18 to 60) Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS

More information

CAUTION. Check Equipment and Job Site. Clearance Requirements. Unpack Unit

CAUTION. Check Equipment and Job Site. Clearance Requirements. Unpack Unit INSTALLATION IMPORTANT: Effective January 1, 2015, all split system and packaged air conditioners must be installed pursuant to applicable regional efficiency standards issued by the Department of Energy.!

More information

Installation Instructions

Installation Instructions 25HBB, 25HBC Baset Series Heat Pumps with Puronr Refrigerant 1 --- 1/2 To 5 Nominal Tons Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS

More information

Installation Instructions

Installation Instructions 214D, 215B, 225B Single -Stage Split System Heat Pump with Puronr Refrigerant 1 1/2 To 5 Nominal Tons Installation Instructions NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions PREFERREDT SERIES AIR CONDITIONER WITH PURONR REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Installation Instructions Fig. 1 --- 538A NOTE: Read the entire instruction manual before starting the installation. TABLE

More information

Installation Instructions

Installation Instructions Installation Instructions SPLIT SYSTEM Premium Line AC & HP CONDENSERS Save This Manual for Future Reference 421 01 3201 07 Dec. 2004 Installation Instructions Split System Condensers Installation/ Startup

More information

Installation Instructions

Installation Instructions Installation Instructions SPLIT SYSTEM Performance Line AC & HP CONDENSERS NOTE: See Back Cover for shipping bracket Save This Manual for Future Reference 421 01 3001 07 Dec. 2004 Installation Instructions

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

Residential Piping and Long Line Guideline

Residential Piping and Long Line Guideline AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

38TKB Air Conditioning Unit Installation and Start-Up Instructions

38TKB Air Conditioning Unit Installation and Start-Up Instructions 38TKB Air onditioning Unit Installation and Start-Up Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATION Improper installation, adjustment, alteration,

More information

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA INSTALLATION INSTRUTIONS Low Ambient Kit NASA201LA, NASA401LA These instructions must be read and understood completely before attempting installation. DANGER, WARNING, AUTION, and NOTE The signal words

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions Evaporator Coil A Coil --- Cased Multipoise NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. Installation NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION... 2 Inspect Equipment... 2 Select

More information

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA TXV Coils EDM, EDD, EDA These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system to

More information

Installation Instructions

Installation Instructions CNPHP Cased N Coils Horizontal Heating --- Cooling NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

Installation Instructions

Installation Instructions 25HBB, 25HBC, 25HCD Comfortt Series Heat Pumps with Puronr Refrigerant 1 1/2 To 5 Nominal Tons Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY

More information

Installation Instructions

Installation Instructions CNPHP Cased N s Horizontal Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION...

More information

Installation Instructions

Installation Instructions Installation Instructions SPLIT SYSTEM Premium Line AC & HP CONDENSERS Save This Manual for Future Reference 421 01 3201 07 Dec. 2004 _ Installation Instructions Installation/Startup Information These

More information

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES 11-AC11D2-5 INSTALLER'S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Models: Condensing Units 2A7A5024-048, 2A7A4018-060, 2A7A2018-060 & 2A7A1018-060 IMPORTANT

More information

Installation Instructions

Installation Instructions 113A, 114A, 116B Legacyt N Line Air onditioners with Puronr efrigerant 1-1/2 To 5 Nominal Tons Installation Instructions SAFETY ONSIDEATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

INSTALLATION INSTRUCTIONS R 22 Heat Pump Outdoor Component

INSTALLATION INSTRUCTIONS R 22 Heat Pump Outdoor Component 2H3**GK, 2H3**GH, 2H3**GL These instructions must be read and understood completely before attempting installation. DANGE, WANING, AUTION, and NOTE The signal words DANGE, WANING, AUTION, and NOTE are

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLE OF CONTENTS SAFETY LABELING AND SIGNAL WORDS... 2 UNIT DIMENSIONS... 3 SAFE INSTALLATION REQUIREMENTS... 3 LOCATING THE UNIT... 3 CLEARANCES...

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

INSTALLATION INSTRUCTIONS Apartment Fan Coil

INSTALLATION INSTRUCTIONS Apartment Fan Coil Apartment Fan oil Product Family: FSA2X, FSA4X These instructions must be read and understood completely before attempting installation. DANE, WANIN, AUTION, and NOTE The signal words DANE, WANIN, AUTION,

More information

Installation Instructions

Installation Instructions KSALA0201R22 KSALA0301410 Low--Ambient Pressure Switch Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,

More information

Installation Instructions

Installation Instructions Performance Series Heat Pumps with PURONr Refrigerant 1 --- 1/2 to 5 Nominal Tons Installation Instructions Fig. 1 --- A07532 NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER! 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS INSTALLATION GUIDE R-410A ATTENTION, INSTALLER! After installing the system, show the user how to turn off electricity to the unit. Point out control and switch

More information

Installation Instructions

Installation Instructions 25HHA4 Performance Series Heat Pump with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-25HHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

AC10B FEATURES UNIT DIMENSIONS. Ducane Air Conditioner. THE DIFFERENCE IS QUALITY

AC10B FEATURES UNIT DIMENSIONS. Ducane Air Conditioner. THE DIFFERENCE IS QUALITY R FEATURES Durable Copeland compressors, with internal pressure relief valves and inherent thermal protection High quality Ducane made condenser coil with copper tubing and enhanced louvered fin for maximum

More information

CONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS INSTALLATION INSTRUCTION MODELS H*DE018 THRU H*DE060 NOMENCLATURE GENERAL LIMITATIONS INSPECTION

CONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS INSTALLATION INSTRUCTION MODELS H*DE018 THRU H*DE060 NOMENCLATURE GENERAL LIMITATIONS INSPECTION INSTALLATION INSTRUCTION CONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS Supersedes: 550.44-N1Y (1194) 550.44-N1Y (495) MODELS H*DE018 THRU H*DE060 035-11029 WARNINGS are given to alert the installer

More information

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS DLCSRA INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only.

More information

CONDENSING UNITS SPLIT-SYSTEM COOLING 6-1/3 TONS INSTALLATION INSTRUCTION MODELS H*DB076 NOMENCLATURE GENERAL LIMITATIONS INSPECTION REFERENCE

CONDENSING UNITS SPLIT-SYSTEM COOLING 6-1/3 TONS INSTALLATION INSTRUCTION MODELS H*DB076 NOMENCLATURE GENERAL LIMITATIONS INSPECTION REFERENCE INSTALLATION INSTRUCTION CONDENSING UNITS SPLIT-SYSTEM COOLING 6-1/3 TONS Supersedes: Nothing 550.38-N6Y (1095) MODELS H*DB076 035-13578 WARNINGS are given to alert the installer that severe personal injury,

More information

Installation Instructions

Installation Instructions 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models EBP EBX EBXX(R -410A) CAUTION Use ONLY factory listed electric heaters. Safety Labeling and Signal Words Danger, Warning and Caution The signal words DANGER, WARNING and

More information

Split system air conditioner. *S4BE - 018KB, 024KB, 030KB, 036KB (1.5, 2, 2.5, & 3 Ton) Series

Split system air conditioner. *S4BE - 018KB, 024KB, 030KB, 036KB (1.5, 2, 2.5, & 3 Ton) Series Split system air conditioner 14 SEER, Single Phase Models Installation Instructions *S4BE - 018KB, 024KB, 030KB, 036KB (1.5, 2, 2.5, & 3 Ton) Series IMPORTANT ATTENTION INSTALLERS: It is your responsibility

More information

Installation Instructions

Installation Instructions 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... DLCMRA INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4

More information

INSTALLATION MANUAL R-22/R-407C OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: GCGA SERIES 1.5 TO 6.3 TONS 1 & 3 PHASE LIST OF SECTIONS LIST OF FIGURES

INSTALLATION MANUAL R-22/R-407C OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: GCGA SERIES 1.5 TO 6.3 TONS 1 & 3 PHASE LIST OF SECTIONS LIST OF FIGURES INSTALLATION MANUAL R-22/R-407C OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: GCGA SERIES 1.5 TO 6.3 TONS 1 & 3 PHASE GENERAL..............................................1 SAFETY................................................1

More information

CONDENSING UNIT INSTALLATION INSTRUCTIONS. AIR CONDITIONING INSTALLATION & SERVICE REFERENCE Important Safety Instructions. Shipping Inspection

CONDENSING UNIT INSTALLATION INSTRUCTIONS. AIR CONDITIONING INSTALLATION & SERVICE REFERENCE Important Safety Instructions. Shipping Inspection INSTALLATION INSTRUTIONS ONDENSING UNIT AIR ONDITIONING INSTALLATION & SERVIE REFERENE Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate

More information

CONDENSING UNIT INSTALLATION INSTRUCTIONS

CONDENSING UNIT INSTALLATION INSTRUCTIONS ONDENSING UNIT INSTALLATION INSTRUTIONS ONDENSING UNIT SAFETY PRES...1 Important Note to the Owner Regarding Product Warranty...2 Shipping Inspection...2 odes and Regulations...2 Installation learances...2

More information

CONDENSING UNIT WARNING AIR CONDITIONING INSTALLATION & SERVICE REFERENCE. Important Safety Instructions. Shipping Inspection. Codes & Regulations

CONDENSING UNIT WARNING AIR CONDITIONING INSTALLATION & SERVICE REFERENCE. Important Safety Instructions. Shipping Inspection. Codes & Regulations ONDENSING UNIT AIR ONDITIONING INSTALLATION & SERVIE REFERENE Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards.

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

38GHP AIR-COOLED MULTI SPLIT CONDENSING UNITS

38GHP AIR-COOLED MULTI SPLIT CONDENSING UNITS Concepcion Carrier Air conditioning Company Philippines INSTALLATION MANUAL, START-UP & SERVICE INSTRUCTIONS 38GHP AIR-COOLED MULTI SPLIT CONDENSING UNITS CONTENTS: Physical Data and Dimensions........

More information

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215) National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215) 244-1400 1-800-523-7138 Fax: (215) 244-9579 R410a SPLIT-SYSTEM CONDENSING UNIT INSTALLATION INSTRUCTIONS 1000 3000 4000 SERIES 1.

More information

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215) National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215) 244-1400 1-800-523-7138 Fax: (215) 244-9579 SPLIT-SYSTEM CONDENSING UNIT INSTALLATION INSTRUCTIONS 1000 3000 4000 SERIES 1. 2. 3.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No

More information

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump Packaged Heat Pumps Owner s Guide to Operating and Maintaining Your Heat Pump NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces

More information

Installation Instructions

Installation Instructions Infinity Series Heat Pump with Puron Refrigerant 2 To 5 Nominal Tons (Sizes 24 to 60) Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS....................... 2 INSTALLATION RECOMMENDATIONS.............

More information

Fig. 1 - Unit PHD4 and WPH4

Fig. 1 - Unit PHD4 and WPH4 OWNER S MANUAL 14 SEER Single -Package Heat Pump System with R -410A Refrigerant Single Phase and Three Phase 2 to 5 Nominal Tons PHD4 Series F and WPH4 Series B Fig. 1 - Unit PHD4 and WPH4 A09034 NOTE

More information

Installation Instructions

Installation Instructions Installation Instructions Cased Horizontal Furnace Coil CK3B A96318 Fig. 1 Model CK3B Furnace Coil NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper

More information

Installation Instruction

Installation Instruction DLFCAB / DLCCAR / DLFCHB / DLCCHR DLFDAB / DLCDAR / DLFDHB / DLCDHR High- Wall Ductless Split System Sizes 09-36 Installation Instruction NOTE: Read the entire instruction manual before starting the installation.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2014 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUTIONS Merit Series 14HPX Units HEAT PUMP 506773-01 3/2014 Supersedes 6/2013 Litho U.S.A. THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR

More information

Installation Instructions

Installation Instructions 38MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 30, 36 and 48 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS...

More information

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioner

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioner SA6, HSA6, TSA6 These instructions must be read and understood completely before attempting installation. IMPOTANT: Effective January 1, 2015, all split system and packaged air conditioners must be installed

More information

NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. BBM Series Installation Instructions AIR HANDLER IMPORTANT Please read all information in this manual thoroughly and become familiar with the capabilities and use of your appliance before attempting to

More information

Horizontal/Side Discharge Condensing Units

Horizontal/Side Discharge Condensing Units INSTALLATION, OPERATION & MAINTENANCE MANUAL Horizontal/Side Discharge Condensing Units Models CMA12SD-0 CMA18SD-1 CMA24SD-1 CMA30SD-1 CMA36SD-1 CMA48SD-1 517.787.2100 www.marsdelivers.com Horizontal/Side

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

Installation Instructions

Installation Instructions PH13N SPLIT -SSTEM HEAT PUMP F USE WITH -22 EFIGEANT SIZES 018-060 Installation Instructions SAFET NSIDEATINS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion,

More information

For 18 SEER R410A Series Unitary Ducted Split AC

For 18 SEER R410A Series Unitary Ducted Split AC For 18 SEER R410A Series Unitary Ducted Split AC Thermostat Owner's Manual Commercial Air Conditioners Thank you for choosing MRCOOL, please read this owner s manual carefully before operation and keep

More information

INSTALLATION / START-UP INSTRUCTIONS 4HP13/14 SPLIT SYSTEM HEAT PUMP HOMEOWNERS INFORMATION MANUAL

INSTALLATION / START-UP INSTRUCTIONS 4HP13/14 SPLIT SYSTEM HEAT PUMP HOMEOWNERS INFORMATION MANUAL INSTALLATION / START-UP INSTRUCTIONS 4HP13/14 SPLIT SYSTEM HEAT PUMP HOMEOWNERS INFORMATION MANUAL TABLE OF CONTENTS These instructions must be read and understood completely before attempting installation.

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

Installation Owner Diagnostics

Installation Owner Diagnostics Installation Owner Diagnostics Split System Cooling Condensers Model CTA 7 1/2 to 15 Tons Models A and later Design Sequence CTA 090A***A 60 HZ 120A***A 60 HZ 120B***A 60 HZ 180B***A 60 HZ SS-SVN11A-EN

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

SPLIT SYSTEM HEAT PUMP INSTALLATION / START-UP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL

SPLIT SYSTEM HEAT PUMP INSTALLATION / START-UP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL SPLIT SYSTEM HEAT PUMP INSTALLATION / START-UP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL These instructions must be read and understood completely before attempting installation. TABLE OF CONTENTS Issue

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS STELLAR AIR CONDITIONING UNIT SPLIT-SYSTEM COOLING CONTENTS GENERAL..................................... 2 NOMENCLATURE........................... 2 SAFETY...................................

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP13LE Series Split System Heat Pump

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP13LE Series Split System Heat Pump INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP13LE Series Split System Heat Pump WARNING The equipment covered in this manual is to be installed by trained and experienced service and installation technicians.

More information

Installation Instruction

Installation Instruction 40GRQ / 619FB / 38GRQ / 538FR High- Wall Ductless Split System Sizes 09-18 Installation Instruction NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS R 410A Ducted Horizontal Air Conditioner Product Family: HC4A3 Fig. 1 - HC4A3 NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE

More information

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA TXV Coils EBD, EBA These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system to operate

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA TXV s EBU, EBA These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system to operate

More information

Installation Instruction

Installation Instruction Installation Instruction Upflow Downflow Heating Cooling CC5A Uncased Coil CD5A Cased Coil SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Installation of CD5A Cased Coil A96244 NOTE:

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING The equipment covered in this manual is to be installed by trained and experienced service and installation

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP16LT Series Split System Heat Pump

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP16LT Series Split System Heat Pump INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP16LT Series Split System Heat Pump WARNING The equipment covered in this manual is to be installed by trained and experienced service and installation technicians.

More information

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1

More information