Midea Air Conditioners Chiller System

Size: px
Start display at page:

Download "Midea Air Conditioners Chiller System"

Transcription

1 GD Midea Coercial Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong, 5811, P.R.China Tel: Fax: Http: Http: (customer service) 007 Midea Air Conditioners Chiller System Midea Is Your Idea

2 TUV Rheiniand geprufte sicherheit EUROVENT CERTIFIED PERFORMANCE CERTIFIED COMPANY Production inspected CERTIFIED COMPANY I.. geprufte Sicherheit Midea Creates A Better Life Midea produced its first Air Conditioner in Currently we are the leader of Air conditioner manufacturing and export. Midea has been exporting Air Conditioners for the last 16 years, and during this time Midea has cultivated strong partnerships with hundreds of overseas companies. Our vertically integrated supply chain enables us to achieve maximum efficiency in production and product development. Midea is dedicated to continuous improvement. Over 1000 engineers work together to push the improvement of AC technology. Every year over 00 new products are developed and 100 new patents are filed. New products account for 0% of total sales volume and 5% of gross profit. e provide Global technical training and a comprehensive online customer service. All our customers from over 110 countries and regions receive top quality service at all times. Our goal is to deliver the highest quality products to our costumers. Quality is one of the core competencies of Midea. NRTLC 068 ISO 9001 : 000 Certificate No.: CC ISO 14001: 1996 Certificate No.:CC1417 L S T E D I N T E R N A T I O N A L SAUDI ARABIAN STANDARDS ORGANIZATION C O N F O R M I T Y PR O G R A M C E R T I F I C A T I O N N4 TUV Rheiniand Group 1

3 007 Midea Coercial AC Line Up [ L ] Centrifugal Chiller system [ ] ater-cooled Package Unit R1 single-stage compression: 00RT~800RT R1 dual-stage compression: 900RT~100RT R14a single-stage compression: 50RT~1100RT R14a dual-stage compression: 100RT~000RT 5 100~145 [ R ] Heating ater System [ C ] ater-cooled Screw Chiller system 49-5 Dry expansion evaporator: Single-compressor: 40RT~45RT Dual-compressor: 80RT~490RT Flooded type evaporator: Single-compressor: 10RT~55RT Dual-compressor: 90RT~510RT [ S ] ater-source Heat Pump ~ ater source ater source ater source four way cassette low static pressure duct high static pressure duct [ A ] Air-cooled Modular Chiller System 4-44 [ K ] Air Handling Unit & Fan Coil Unit Air Handling Unit 6-71 Single wall horizontal type Single wall vertical type Dual wall horizontal type Dual wall vertical type all-mounted type Fan Coil Unit Digital scroll or constant speed scroll: 0~50 Constant speed scroll:185~1480 Four way cassette (compact) Four way cassette One way cassette Duct type Concealed floor standing Expoded floor standing 4

4 [ L ] Series Centrifugal Chiller system

5 Centrifugal Chiller system HO TO READ THE MODELS? M H C - A S 650 S A N Refrigerant Type: N R14a N5 R1 - R Power Type: A 0V50HzPh B 10000V50HzPh C 80V50HzPh Brief introduction of R-14a series R-14a series hermetic centrifugal chiller system, are developed to replace the current CFC centrifugal chiller series for the project national scheme of China ozone layer consuming material gradually falling into disuse. The series take the environmental friendly refrigerant HFC-14a as refrigerant. On august 1999, the first sample170h-6p centrifugal chilled system gained the approval as national class new product, professional team's appraisal: unit's main technical performance is advanced among the same kind of products, with friendly environmental quality and excellent energy-saving effect, the market prospect is expansive. Compressor Type: H Hemetic S Semi-hermetic O Opening Nominal (USRT) Compression-stage: S Single-stage Compression D Dual-stage Compression Compression Quantity: A Single Compressor D Dual Compressor Centrifugal Chiller Heavy Coercial Chiller System Midea 7 8

6 Centrifugal Chiller system Features Adopt new-type environmental friendly refrigerant R-1 series centrifugal chiller system take HCFC-1 as refrigerant. HCFC-1 is an optimal choice considering ozone depleting, greenhouse effect and energy effect. R-14a series centrifugal chiller system take HCFC-14a as refrigerant. HCFC-14a is the green refrigerant accepted internationally, without destructive effect to ozone, and accords to the standards of international environmental protection pact and national scheme of china consume ozone material gradually falling into disuse. Advanced technology & high efficiency The pneumatic part of compressor is designed through NREC pneumatic software which is one of the most advanced design softwares in the world. Adopts high-efficiency and three-dimension hermetical impeller designed for refrigerant HCFC-1HFC- 14a, avoids performance fluctuation caused by gap change between semi-open impeller and scrollcase. The heat transfer pipes of condenser and evaporator adopt high efficiency heat transfer pipes designed individually according to boil principle and concreting principle, improve gross heat transfer coefficient and as well as be able to realize the heat transfer with small temperature difference. The optimal matching of advanced compressor with new-style & highefficiency heat exchanger guarantees a high efficiency unit. Special designed guide vane can adjust refrigerant mass flow to fulfil partial load requirement, and by pre-regulating gas entering direction, refrigerant can flow into the propeller in optimal angle and Propellor overspeed test on overspeed experiment device of German Schenk unit efficiency is improved greatly. An extra high-efficiency cooler in condenser subcools liquid refrigerant and improves the efficiency. The energy saver between double stage compressors reduces unit power consumption by 5%, so as to increase cooling capacity of refrigerant per mass unit and compressed quantity of refrigerant entering into the first stage reduces, otherwise, refrigerant at intermediate pressure between evaporator and condenser will flash and the refrigerant between stages cooled by flash gas will improves unit*s efficiency. Optimize the pipe arrangement, reduce the refrigerant friction loss, and guarantee excellent operation efficiency. Reliable gearing & long-span operation Less moving parts in compressor and high quality components guarantee a coon lifespan over 0 years. The propeller is made of peculiar cast aluminium alloy and proved to be of sufficient mechanical strength and high erosion resistance after high precision dynamic balance test and over-speed test. The keyless connection between propeller and axis avoids the stress concentration and accessional unbalance of rotor. It will improve the reliability considerably. The technology obtained the national patent, the patent serial number is ZL Peculiar design of high precision helical gear counteracts the axial thrust force caused by propeller, reduces the gearing's load and makes the transmission smoothly. Hermetic motor is cooled efficiently by evaporative refrigerant ejecting. Therefore, it ensures unit safety and long lifespan and also can prevent the refrigerant from leakage. Reliable lubricating system The closed oil pump iersed in oil can send the pressure oil to the surface of each high-speed gear. Plate oil cooler cooled with refrigerant ensures the oil pumped by oil pump to be cooled to a low temperature. Impurity in oil is filtered by high precision papery filter. ensures the dynamic pressure oil film forming on high-speed gearing, and filter core can be replaced conveniently. The high oil box on top of compressor ensures the oil quantity used for gearing when emergent poweroff occurs, and avoids the gearing from abrasion. ide range of adjustable capacity The chiller system of medium & large capacity adopts nonvane pressure enlarger and inlet guard vane, hence enlarge cooling adjusting range, and the unit's coolingcapacity can be adjusted optionally from 10% to 100% at a invariable cooling water inlet temperature. Inlet guide vane 9 10

7 Centrifugal Chiller system Features Low noise & stable running All the gears are rectified in height and width in order to reduce the mesh noise. The double-layer noise proof structure of gear box minimizes the noise level. Flux passage with optimized design reduces the noise level and refrigerant flow speed. Noise-proof device fixed on the inlet of condenser can reduce the refrigerant flow impact noise. The special design of compressor assembled with hermetic motor cooling by refrigerant saves the connecting and hermetic device between motor and compressor which is necessary for unclosed motor, and reduces damageable process, as well as reduces the motor outline dimension and motor noise. The unit's mean-time to failure can be more than five years. Reliable performance test Reliable performance test The assemblage of propeller with gear is tested in dynamic balance experiment with an over-speed which is 10% of the rated. Heat exchanger and power saver are strictly tested by pressure experiment according the national norm JB4750 defined by pressure container for refriferation quipment. Must carry out gas seal test and vacuum test after whole unit is assembled. The performance test is operated on special experiment table according to national standard, strictly tested each norm, and can't leave factory until it fulfil the design demand. ider application balance test on Schenck Dynamic balancing machine (Germany) Be able to customize special centrifugal compressor with large cooling capacity and dual-compressor according to user's demand, capacity of single unit can reach up to 4000RT. Be able to design high-voltage products of 0v or 10000v, reduces the impact to electric network, as well as save the transformer, has wider application. Be able to design non-standard products based on actual temperature of water inlet and outlet, so as to achieve the best energy-saving effect, fulfil user's demand. Advanced Micro-computer control system The special designed micro-computer control system can optimize control logic, improve operation efficiency, is reliable with long-term running. Touchpad display makes the operation easy and direct. Operation data and malfunction alarms can be displayed on the indicator, so to monitor unit instantly. The micro-computer control system can execute more than 0 control and protection actions and record the latest 10 error parameters, main control unit adopting advanced import components which have better disturbance resistance and guarantee the units work safely and reliably. The built-in RS4 counication port can realize central control. It also can connect with user's PC, and realizes remote control start, operation and stop. Adopts the PLC controller of CQM1-Japanese Omilong series to precisely control temperature. The control system adopts EL highlight touchpad display of GP-477 series produced by Japanese DIGITAL, and the moving picture will display operation interface, and operates each control by slight touch refer to wok condition indicator. In central monitor system, the micro-computer is connected with the CPU modules of multi sets of centrifugal chiller systems micro-computer control system (PC-LXZ-H) through RS4 port, can control maximum sets of centrifugal refrigerators and the water pump, cooling tower and other accessories. Standing-by interface Malfunction display interface Coefficient display interface Approval Design, manufacture and experiment of unit are all according to the national standard GBT vapor compression cycle ater chilling (heat pump) packages and JB 4750 pressure container for refrigerating device. Our company has obtained ISO 9001 certification, and it is the first to obtain environment product approval in national trade. 11 1

8 Centrifugal Chiller system R-1 single-stage series (00-400RT) R1 single-stage series ( RT) Unit 00 MHC-AS(00-400)HA(B)(C)N Unit 500 MHC-AS( )HA(B)(C)N RT RT Refrigerating capacity Refrigerating capacity kcalh kcalh Cooling water flow m h Cooling water flow m h Evaporator Cooling water pressure drop KPa Evaporator Cooling water pressure drop KPa nominal diameter DN00 DN00 nominal diameter DN50 DN50 DN00 DN00 Chilled water flow m h Chilled water flow m h Condenser Chilled water pressure drop KPa Condenser Chilled water pressure drop KPa nominal diameter DN00 DN00 nominal diameter DN50 DN50 DN00 DN00 Capacity Capacity Motor Coolingsystem V-ph-HZ Refrigerant ejecting Motor Coolingsystem V-ph-HZ Refrigerant ejecting R1 charge volume Lubricant oil charge volume Unit weight Unit dimensions Unit transport eight Unit running weight Length (A) idth (B) Height (C) R1 charge volume Lubricant oil charge volume Unit transport eight Unit weight Unit running weight Length (A) Unit dimensions idth (B) Height (C) cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard. 1. cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard. 1 14

9 Centrifugal Chiller system R-1 dual-stage series ( RT) R14a single-stage series (50-500RT) Unit 900 MHC-AD( )HA(B)(C)N Unit 50 MHC-AS(50-500)HA(B)(C)N RT RT Refrigerating capacity Refrigerating capacity kcalh kcalh Cooling water flow m h Cooling water flow m h Evaporator Cooling water pressure drop KPa Evaporator Cooling water pressure drop KPa nominal diameter DN00, PN1.0 DN00, PN1.0 DN00, PN1.0 DN00, PN1.0 nominal diameter DN00 DN00 DN00 DN00 Chilled water flow m h Chilled water flow m h Condenser Chilled water pressure drop KPa Condenser Chilled water pressure drop KPa nominal diameter DN50, PN1.0 DN50, PN1.0 DN50, PN1.0 DN50, PN1.0 nominal diameter DN00 DN00 DN00 DN00 Capacity Capacity Motor Coolingsystem V-ph-HZ Refrigerant liquid ejecting-evaporating Motor Coolingsystem V-ph-HZ Refrigerant ejecting R14a charging volume R1 charge volume Lubricant oil charge volume R14a charge volume Lubricant oil charge volume Unit weight Unit transport eight Unit running weight Unit weight Unit transport eight Unit running weight Length (A) Length (A) Unit dimensions idth (B) Unit dimensions idth (B) Height (C) Height (C) cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard. Support setting dimensions D E F G H J K L cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard

10 Centrifugal Chiller system R-14a single-stage series( rt) R-14a single-stage series ( RT) Unit 550 MHC-AS( )HA(B)(C)N 650 Unit 700 MHC-AS( )HA(B)(C)N RT RT Refrigerating capacity Refrigerating capacity kcalh kcalh Cooling water flow m h 6 9 Cooling water flow m h Evaporator Cooling water pressure drop KPa Evaporator Cooling water pressure drop KPa nominal diameter DN50 DN50 DN50 nominal diameter DN50 DN50 DN50 DN00 Chilled water flow m h Chilled water flow m h Condenser Chilled water pressure drop KPa Condenser Chilled water pressure drop KPa nominal diameter DN50 DN50 DN50 nominal diameter DN50 DN50 DN50 DN00 Capacity Capacity Motor Coolingsystem V-ph-HZ Refrigerant ejecting R14a charging volume Motor Coolingsystem V-ph-HZ Refrigerant ejecting R14a charging volume R14a charge volume Lubricant oil charge volume Unit weight Unit dimensions Unit transport eight Unit running weight Length (A) idth (B) Height (C) R14a charge volume Lubricant oil charge volume Unit weight Unit dimensions Unit transport eight Unit running weight Length (A) idth (B) Height (C) Support setting dimensions D E F G H J K L Support setting dimensions D E F G H J K L cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard. 1. cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard

11 Centrifugal Chiller system R-14a single-stage series ( RT) R-14a double-stage series ( RT) Unit 900 MHC-AS( )HA(B)(C)N Unit 100 MHS-AD( )HA(B)(C)N RT RT Refrigerating capacity Refrigerating capacity kcalh kcalh Cooling water flow m h Cooling water flow m h Evaporator Cooling water pressure drop KPa Evaporator Cooling water pressure drop KPa nominal diameter DN00 DN00 DN00 DN00 nominal diameter DN50 DN50 DN50 DN50 DN400 DN400 Chilled water flow m h Chilled water flow m h Condenser Chilled water pressure drop KPa Condenser Chilled water pressure drop KPa nominal diameter DN00 DN00 DN00 DN00 nominal diameter DN50 DN50 DN50 DN50 DN400 DN400 Capacity Capacity Motor Coolingsystem V-ph-HZ Refrigerant ejecting R14a charging volume Motor Coolingsystem V-ph-HZ Refrigerant liquid ejecting-evaporating R14a charge volume Lubricant oil charge volume R14a charge volume Lubricant oil charge volume Unit weight Unit transport eight Unit running weight Unit weight Unit transport eight Unit running weight Length (A) Length (A) Unit dimensions idth (B) Unit dimensions idth (B) Height (C) Height (C) Support D E Support D E F F setting dimensions G H J K setting dimensions G H J K L L cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard. 1. cooling water inletoutlet temperature :17 O C chilled water inletoutlet temperature: 7 O C waterside fouling factor : 0.086m O C. Designed waterside pressure of both cooling water and chilled water is 1.0 MPa, water connecting pipe flange standard: JBT Inform us specificallywhen ordering the unitif the waterside working pressure is higher than 1.0MPa.. The listed data in those samples may change, please refer to factory drawings offered by our company for standard. 19 0

12 Centrifugal Chiller system Notices for order Users should offer technical requirements as follow: Cooling capacity Inlet temperature of chilled water [ C ] Series Outlet temperature of chilled water Inletoutlet temperature of cooling water Coolingchilled water side fouling factors for special requirement (m. 0 C) hether there is different piping azimuth comparing with the sample Voltage level of main motor Special control requirements Coolingchilled water pressure for special requirement Special instruction User should self-supply base steel plate and cables between start cabinet and motor. e suggest utilizing special refrigerant filler and charger to avoid refrigerant loss and leakage. e supply two types of refrigerant fillers and chargers and relative refrigerant storages for user, which is not belong to supply scope of our company, please contact with sale department of our company for order. ater-cooled Screw Chiller system Supply scope of a set centrifugal chiller system A centrifugal compressor (include speeding-up device) A main motor (motor cooled with refrigerant) An evaporator and condenser A refrigerant purifier (only applicable to series of R-1 single and dual-stage unit) One lubricating system An electric control cabinet (self-supply cables between electric box start cabinet) A start cabinet (will supplied by user when main motor voltage is 0v or 10000v) A power saver (available for R1 and R-14a dual-stage series) 1

13 Screw Chiller system HO TO READ THE MODELS? M H S - A F 650 S A N Refrigerant Type: N R14a N5 R1 - R Power Type: A 0V50HzPh B 10000V50HzPh C 80V50HzPh Compressor Type: H Hemetic S Semi-hermetic O Opening Nominal (USRT) Advanced screw dual-compressor technology Adopts advanced industrial generation * compressor with 5-6 asyetry dentiform design, the mechanical configuration of which is manufactured by CNC high precision screw rotor, each part is well-proportioned, no gap matching, minimizes the friction resistance, guarantees quiet running and well duration. Comparing with single screw compressor has the advantages of no clearance loss, high volume efficiency, low running noise, less damageable parts, etc. Evaporator Type: F Flooded Type D Dry Type Compression Quantity: A Single Compressor D Dual Compressor Screw Chiller Heavy Coercial Chiller System Midea 4

14 Screw Chiller system Variable volume adjustment, High efficiency & energy-saving Owning the biggest single compression ratio, the ratio can reach up to 18. Compressor with adjustable variable volume and special volume control valve for precise control enables to adjust compressor's refrigerant compressed amount precisely matching with load change. Realizes 4-stage capacity output control (5%, 50%, 75%, and 100%) and stepless capacity control (need special instruction for the function on order). The high precise adjustable volume directly saves user's operation cost. Capacity output 100% 75% 50% Introduction of components Adopting the world-famous brand key components, ensures the unit running with reliability & safety. Compressor Adopts high efficiency screw compressor of generation * with 5-6 asyetry dentiform, the screw rotor of which gained patent by improving the shape of German rotor GHH, proved having well balance, small vibration, low noise due to balance testing by balance machine. Heat efficiency of the rotor with main and subsidiary rotor adopting 5-6 dentiform increases by 10-1% and energy saves by 5%, comparing with Chinese normal screw rotor with 4-6 dentiform. The rotor shape also gained British and American patent. Adopts compressor bearing SKF from Sweden, the long lifespan of which ensure screw-type main unit to run continuously more than hours. Four-step capacity adjustment 5% Oil separator Stepless capacity adjustment The product comes from MANN of German, has reliable qualification, oil content can be controlled below ppm (oil content treated by oil-gas separator of coon domestic like screw-type air compressor is 5% 50% 75% 100% Capacity demand not less than 8-10ppm). oil-gas separated amount is double of same kind of products, the large oil filtering area reduces refrigerant flux speed, and has better separating effect and long lifespan by adopting Refrigerant circulation and lubricating system secondary reflux technology. Condenser Midea screw chiller is equipped with high efficiency shell and tube condenser, it is constructed by seamless steel tube with anti-corrosive treatment, the pressurization is 1.9Mpa, and the pressurization of water pipe side is 1.0Mpa. water pipe constructed with seamless integrally finned copper attains optimal heat exchange efficient, two return passages of water flow and the straight water pipe is easy for cleaning and maintenance, both end covers are made of iron, the covers attached with protection valve and snuffle valve and etc are removable, makes it available for altering water piping arrangement. The condenser is mounted with devices as protection valve and snuffle valve, etc. Evaporator The pressurization of direct expanding shell and tube evaporator wrapped with heat insulating and flameproof material is 1.4Mpa, the inner refrigerant evaporation pipe of which is constructed with seamless steel pipe together with internal-screw cooling fin, guarantees a high efficient heat transmission, the Item Contents Item Contents pressurization is 1.0 MPa. ater flowing along refrigerant pipe outside and the installation of the flashing 1 Filter Refrigerant (low pressure) Motor Lubricant Oil separator Refrigerant (high pressure) PP makes chilled water to flow up-down along the chilled water clapboard, improves heat transmission efficiency Oil filter Bearing Compressor rotor Bearing Capillary Electromagnetic valve (starting) Electromagnetic valve (50% energy output) Electromagnetic valve (75% energy output) Refrigeration cycle Consists of the high pressure check-valve, expansive valve, electromagnetic valve, bulbiform valve, display panel, water indicator, dry filter, etc. Each multiple evaporator inside has independent refrigerant cycle 8 9 Discharge pipe Refrigerant (high pressure mix with oil) 17 Capability adjustment device pipes, avoiding system imbalance. 5 6

15 Screw Chiller system Dry type (single compressor series) Dry type (single compressor series) 40 MHS-AD(40-70)SC MHS-AD(85-140)SC Cooling capacity Power input Unit color USRT Grey Cooling capacity Power input Unit color USRT Grey Dimension (L x x H) Compressor type Compressor starting mode Fouling factor Design working pressure Capacity adjustment Refrigerant type No. of refrigerant circuits Refrigerant flux adjustment device Refrigerant weight Condenser type Condenser model and number '5-6 Asyetry Dentiform Semi-hermetic Screw Y-* 80V, N~50Hz 0.086m. 0 C ater side pressure is 1.0MPa 50%,75%,100% R 1 Thermo-expansive valve 0 Shell and tube UC050A Dimension (L x x H) Compressor type Compressor starting mode Fouling factor Design working pressure Capacity adjustment Refrigerant type No. of refrigerant circuits Refrigerant flux adjustment device Refrigerant weight Condenser type Condenser model and number '5-6 Asyetry Dentiform Semi-hermetic Screw Y-* 80V, N~50Hz 0.086m. 0 C ater side pressure is 1.0MPa 50%,75%,100% R 1 Thermo-expansive valve 60 Shell and tube UC050A Condenser inlet pipedimension DN80 DN80 DN80 DN100 Condenser inlet pipe dimension DN100 DN100 DN100 DN100 Condenser outlet pipe dimension Cooling water flux volume Evaporator type Evaporator model and number Evaporator inlet pipe dimension Evaporator outlet pipe dimension Chilled water flux volume m h m h DN80 7 DN80 DN80 DN80 5 Dry shell and tube UCH050A1 DN80 DN80 9 DN80 40 DN80 DN80 DN100 5 DN80 DN80 44 Condenser outlet pipe dimension Cooling water flux volume Evaporator type Evaporator model and number Evaporator inlet pipe dimension Evaporator outlet pipedimension Chilled water flux volume m h m h DN DN100 DN DN Dry shell and tube UCH050A1 DN100 DN DN DN100 DN DN DN15 DN15 8 Protection device Highlow pressure protections, over load protection, phase sequence protection, water flux volume protection, oil level protection, discharge temperature protection. Protection device Highlow pressure protections, over load protection, phase sequence protection, water flux volume protection, oil level protection, discharge temperature protection. Unit weight Unit running weight Unit weight Unit running weight The cooling capacities above are tested on the following states. Evaporator inlet water 1 O C, outlet water 7 O C Condenser inlet water 0 O C, outlet water 5 O C The cooling capacities above are tested on the following states. Evaporator inlet water 1 O C, outlet water 7 O C Condenser inlet water 0 O C, outlet water 5 O C 7 8

16 Screw Chiller system Dry type (single compressor series) Dry type (dual compressor series) 165 MHS-AD(165-45)SC MHS-DD(80-60)SC Cooling capacity Power input Unit color USRT Grey Cooling capacity Power input Unit color USRT Grey Dimension (L x x H) Compressor type Compressor starting mode Fouling factor Design working pressure Capacity adjustment Refrigerant type No. of refrigerant circuits Refrigerant flux adjustment device Refrigerant weight Condenser type Condenser model and number '5-6 Asyetry Dentiform Semi-hermetic Screw Y-* 80V, N~50Hz 0.086m. 0 C ater side pressure is 1.0MPa 50%,75%,100% R 1 Thermo-expansive valve 10 Shell and tube UC050A Dimension (L x x H) Compressor type Compressor starting mode Fouling factor Design working pressure Capacity adjustment Refrigerant type No. of refrigerant circuits Refrigerant flux adjustment device Refrigerant weight Condenser type Condenser model and number '5-6 Asyetry Dentiform Semi-hermetic Screw Y-* 80V, N~50Hz 0.086m. 0 C ater side pressure is 1.0MPa 50%,75%,100% R Thermo-expansive valve Shell and tube UC050A x x Condenser inlet pipe dimension DN15 DN15 Condenser inlet pipe dimension DN00 Condenser outlet pipe dimension Cooling water flux volume Evaporator type Evaporator model and number Evaporator inlet pipe dimension Evaporator outlet pipedimension Chilled water flux volume m h m h DN DN15 DN15 98 DN15 11 Dry shell and tube UCH050A1 DN15 DN Condenser outlet pipe dimension Cooling water flux volume Evaporator type Evaporator model and number Evaporator inlet pipe dimension Evaporator outlet pipedimension Chilled water flux volume m h m h Dry shell and tube UCH050A1 18 DN DN00 6 DN00 DN00 16 Protection device Highlow pressure protections, over load protection, phase sequence protection, water flux volume protection, oil level protection, discharge temperature protection. Protection device Highlow pressure protections, over load protection, phase sequence protection, water flux volume protection, oil level protection, discharge temperature protection. Unit weight Unit running weight Unit weight Unit running weight The cooling capacities above are tested on the following states. Evaporator inlet water 1 O C, outlet water 7 O C Condenser inlet water 0 O C, outlet water 5 O C The cooling capacities above are tested on the following states. Evaporator inlet water 1 O C, outlet water 7 O C Condenser inlet water 0 O C, outlet water 5 O C 9 0

17 Screw Chiller system Dry type (dual compressor series) Flooded type (single compressor series) Cooling capacity Power input Unit color Dimension (L x x H) Compressor type Compressor starting mode Fouling factor Design working pressure Capacity adjustment Refrigerant type No. of refrigerant circuits Refrigerant flux adjustment device Refrigerant weight Condenser type Condenser model and number Condenser inlet pipe dimension Condenser outlet pipe dimension Cooling water flux volume Evaporator type Evaporator model and number Evaporator inlet pipe dimension Evaporator outlet pipe dimension Chilled water flux volume Protection device Unit weight Unit running weight USRT m h m h x DN00 DN00 9 DN00 DN00 41 MHS-DD( )SC '5-6 Asyetry Dentiform Semi-hermetic Screw Y-* 80V, N~50Hz 0.086m. 0 C ater side pressure is 1.0MPa 45%,75%,100% 4%,75%,100% 50%,75%,100% R Thermo-expansive valve Shell and tube UC050A Dry shell and tube UCH050A1 Highlow pressure protections, over load protection, phase sequence protection, water flux volume protection, oil level protection, discharge temperature protection DN00 DN00 10 DN00 DN Grey x DN00 DN00 DN00 DN x DN00 DN00 58 DN00 DN USRT Cooling capacity Power input Current (A) Capacity adjustment method Capacity adjustment range (%) Type Refrigerat Charge volume () Chilled water flow (th) Chilled water pressure Condensor drop (kpa) Diam. of inletoutlet water pipe () Cooling water flow (th) Cooling water Evaperator pressure drop (kpa) Diam. of inletoutlet ater pipe () Length (A)() Dimensions idth (B)() Height (C)() Unit weight () Unit running weight () Same technique parameter DN DN DN DN Automatic 5%,50%,75%,100% step or stepless adjustment R DN DN MHS-AF(10-55)SC 40 80V, N~50Hz cooling water inletoutlet temperature:17 O C. chilled water inletoutlet temperature:05 O C. waterside fouling factor:0.086m O C The cooling capacities above are tested on the following states. Evaporator inlet water 1 O C, outlet water 7 O C Condenser inlet water 0 O C, outlet water 5 O C The cooling capacities above are tested on the following states. Evaporator inlet water 1 O C, outlet water 7 O C Condenser inlet water 0 O C, outlet water 5 O C 1

18 Screw Chiller system Flooded type (dual compressor series) Cooling capacity USRT MHS-DF(90-510)SC [ A ] Series Power input Current (A) Capacity adjustment method Automatic Capacity adjustment range (%) 5%,50%,75%,100% step or stepless adjustment Type Refrigerat Charge volume () R V, N~50Hz Condensor Chilled water flow (th) Chilled water pressure drop (kpa) Diam. of inletoutlet water pipe () DN00 DN00 DN00 DN00 DN00 DN00 Evaperator Cooling water flow (th) Cooling water pressure drop (kpa) Diam. of inletoutlet ater pipe () DN00 DN00 DN00 DN00 DN00 DN00 Length (A)() Dimensions idth (B)() Height (C)() Unit weight () Unit running weight () Same technique parameter cooling water inletoutlet temperature:17 O C. chilled water inletoutlet temperature:05 O C. waterside fouling factor:0.086m O C Air-cooled Modular Chiller System The cooling capacities above are tested on the following states. Evaporator inlet water 1 O C, outlet water 7 O C Condenser inlet water 0 O C, outlet water 5 O C

19 Air-cooled Modular Chiller System HO TO READ THE MODELS? M G A - D 65 S N Refrigerant N1 R410A N R407C - R Power Supply S 80V~, 50Hz, Ph General introduction Air-cooled heat-pump unit is a kind of central air conditioner which adopts air as the cooling (heating) source and water as cooling (heating) medium. As a sort of integrated equipment, it need no cooling tower cooling water pump boiler and corresponding auxiliary parts such as pipe system etc, which makes the structure simpler, saves installation space, convenient maintenance and energy saving. Thus it is very suitable for areas that are short of water. Air-cooled heat-pump unit is the first priority in the engineering design for the following conditions: Hot suer and cold winter. No heating boiler and heating-supply pipe system. Heating supply pipe system is unstable or the supplying time is short. Need air-conditioning whole year. Outdoor Unit (Kw) Compressor Type D Digital Scroll Compressor F Fixed Speed Scroll Compressor Product Category A Modular Air-cooled Chiller System P ater-cooled Package Unit H Heating ater System Midea Coercial Digital scroll air-cooled heat-pump modular unit is designed and produced on the basement of sufficiently absorbing the top technology in AC areas, adopting self-control components with high quality which made by world famous producers. Moreover, after improvement, unit can run more efficiently and more stably. Midea Coercial air-cooled heat-pump modular unit can be used widely in civil construction of AC engineering and industrial engineering, such as hotel, villa, restaurant, hospital, factory, etc. It is a wise choice for areas where water is insufficient or there are strict limits on noise level and surroundings. Light Chiller System MDV Accessories Name Function Dimension (xhxd) KJR-08B1E ire controller Control on & off and the running parameter of unit. At most can control 8 modules. 10x10x15 (front) + 87x55x48 (back) FS-1001-H Target-type flowmeter Check the status of water flow and control the whole system... One unit only need one flowmeter. 1 inch screw thread (connect in the water pipe) 5 6

20 Air-cooled Modular Chiller System System features Modular design, flexible combination. There are types (0kw, 65kw, 00kw) and 5 basic units. The maximum of the system is consisted of one main unit and 7 auxiliary units, and the capacity can be up to Adopts Digital Scroll compressor, capacity can be adjusted. (00kw module just adopt fix-speed scroll compressor.) High reliability and efficiency. Easy connection between main unit and auxiliary unit. Intelligentized control. Strong Micro-computer automatic control function, more than twelve self-protect and self-diagnose functions. Advantages Modular design, easy for capacity extension Adopting modular design, numbers of modules can be assembled by connecting each own inlet & outlet pipeline in series. The integrated system has a bigger capacity. The min. capacity is 0 and the max. is Furthermore, any of unit can be set as main unit, so both the design and installation are very flexible. A dopt digital scroll technology, new air-cooled modular design Since traditional air cooled chiller system adjusts energy output by turning ONOFF the compressor, the capacity output is not accurate as Digital Scroll compressor. Midea modular air-cooled chiller system combines digital scroll compressor with constant speed compressor, which can steplessly adjust the capacity output from 0.5 to 100%. In the state of partial capacity loading, the system can adjust the capacity output precisely according to each indoor unit's requirement. Ratio 100% (100%) ON 75% 50% 5% (0%) OFF 0.5% kw capacity output Energy output for traditional modular air cooled chiller system Energy output for digital modular air cooled chiller system Convenient combination, auto control, available capacity adjustment Capacity output ratio % 100% Digital and constant module unit can be combined by simple pipe and signal wiring + + = 95% 90% 85% 80% connection. The capacity output can be adjusted and the load of different module unit 75% 70% can be distributed uniformly by control system % 60% 55% The unit system can adjust output according 50% 45% to requirement without energy waste. 40% 5% 0% 5% + + = 0% 15% 10% K 10K 195K Indoor unit capacity need 60K 5K 90K 455K 50K 65kw digital model 65kw fixed model 7 8

21 Air-cooled Modular Chiller System PMV refrigerant flow adjustment Traditional modular chiller adopts thermo-expansion valve for adjusting, but it cannot adjust refrigerant flow accurately and also will be delay. So it makes the room temperature fluctuating too much that users may be uncomfortable. High efficient heat exchanger For the 0 or 65kw module, we use plate heat-exchanger, and for the 00 kw module, we use shell-andtube heat-exchanger. Chiller water outlet temperature can be adjusted ater outlet temperature can be adjusted according to customers' demand. In cooling mode, the adjustable ranges from 7 0 C to 1 0 C, and in heating mode, it ranges from 45 0 C to 50 0 C. Simple control The wire connection is very simple between modules. The signal wiring connection between two units of 65 module is finished before launch. The two-cores Shielded Twisted Pair is used for signal wire. Each unit can be controlled and monitored by the wiring controller that just connects to main unit. Strong and reliable control system Stepless capacity modulation, more efficiency Operation mode control Automatic and uniform adjusting function among multi compressors Anti-frost and anti-cold air function in heating mode Anti-freezing function of water system in winter Self-protection and Self-diagnosis function: Specification Cooling input Heating input Control type Safety protection device Main module + auxiliary module Compressor input Refrigerant Refrigerant ater flow volume m h ater resistance loss kpa ater system 1000 kcalh 1000 kcalh aterside heatexchanger Max. Pressure MPa ater inletoutlet pipeline diameter MGA-D(0-40)S(N) or MGA-F(0-40)S(N) 80V N~ 50Hz ire control. Manual or automatic startup, the running status display and malfunction alarm, etc. Highlow-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection x x Both R and R407C are available 4.5x x elding, stainless steel, plate heat exchanger x x x x Compressor low and high pressure protection Phase sequence protection Anti-frost protection on cooling mode Anti-frost protection in winter Start continually protection Compressor over current protection Compressor discharge temp. protection Unit Anti-overheat protection Auxiliary heater protection Ensure compressor operate on proper temp. range. Prevent compressor from damaging by wrong phase sequence Prevent evaporator, water pipe or other parts from damaging by low evaporator temp. Prevent evaporator, water pipe or other parts from damaging by low ambient temp. Prevent compressor from damaging by continually start which come of malfunction Prevent compressor from burning out by over current on abominable weather. Ensure compressor operate in a good condition. Prevent compressor from burning out for running on lacking refrigerant or oil. Prevent auxiliary heater from damaging by over high temperature. Air side heat-exchanger Dimension Total weight Packing Optional auxiliary heater Type Air flow volume 10 m h Fan motor input L H kw 1 0.7x x Fin coil 0.7x4 0.7x Notes: 1. Each module is packed separately and the packing size refers to one module only.. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.. Nominal capacities are based on the following conditions: Cooling condition: chilled water inletoutlet: 1 O C7 O C. Outdoor temp:5 O C(DB)4 O C(B) Heating condition: warm water inletoutlet: 40 O C45 O C. Outdoor temp:7 O C(DB)6 O C(B) 4. ater side fouling factor: 0.086m. O Ckw x x L x x H (160 x 104 x 041) x x ater flow switch protection Sensor malfunction protection Prevent unit from damaging by lack of water. Ensure sensor collect correct information so that control system will not make wrong action. 9 40

22 Air-cooled Modular Chiller System Specification Specification 70 MGA-D(70-480)S(N) or MGA-F(70-480)S(N) MGA-D(65-50)S(N) or MGA-F(65-50)S(N) kcalh kcalh kcalh kcalh Cooling input Cooling input Heating input Heating input V N~ 50Hz 80V N~ 50Hz Control type ire control. Manual or automatic startup, the running status display and malfunction alarm, etc. Control type ire control. Manual or automatic startup, the running status display and malfunction alarm, etc. Safety protection device Highlow-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection. Safety protection device Highlow-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection. Main module + auxiliary module Main module + auxiliary module Compressor input Compressor input Refrigerant Both R and R407C are available Refrigerant Both R and R407C are available Refrigerant 4.5x18 4.5x0 4.5x 4.5x4 4.5x6 4.5x8 4.5x0 4.5x Refrigerant 4.5x4 4.5x8 4.5x1 4.5x16 4.5x0 4.5x4 4.5x8 4.5x ater flow volume m h ater flow volume m h ater resistance loss kpa 9.4 ater resistance loss kpa 9.4 ater system aterside heatexchanger Max. Pressure MPa elding, stainless steel, plate heat exchanger 1.0 ater system aterside heatexchanger Max. Pressure MPa elding, stainless steel, plate heat exchanger 1.0 ater inletoutlet pipeline diameter 1 ater inletoutlet pipeline diameter 1 Air side heat-exchanger Type Air flow volume 10 m h Fan motor input L x x x11 Fin coil x1 0.7x x x x16 Air side heat-exchanger Type Air flow volume 10 m h Fan motor input L 4 0.7x x x6 Fin coil x8 0.7x x x x16 Dimension H Dimension H Total weight Total weight Packing L x x H (160 x 104 x 041) Packing L x x H (61 x 104 x 041) Optional auxiliary heater kw Optional auxiliary heater kw Notes: 1. Each module is packed separately and the packing size refers to one module only.. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.. Nominal capacities are based on the following conditions: Cooling condition: chilled water inletoutlet: 1 O C7 O C. Outdoor temp:5 O C(DB)4 O C(B) Heating condition: warm water inletoutlet: 40 O C45 O C. Outdoor temp:7 O C(DB)6 O C(B) 4. ater side fouling factor: 0.086m. O Ckw. Notes: 1. Each module is packed separately and the packing size refers to one module only.. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.. Nominal capacities are based on the following conditions: Cooling condition: chilled water inletoutlet: 1 O C7 O C. Outdoor temp:5 O C(DB)4 O C(B) Heating condition: warm water inletoutlet: 40 O C45 O C. Outdoor temp:7 O C(DB)6 O C(B) 4. ater side fouling factor: 0.086m. O Ckw. 41 4

23 Air-cooled Modular Chiller System Specification Pipe system connection Sketch of (0, 65kw) module connection 1000 kcalh MGA-F(00-1)S(N) overflow water automatically gas discharge valve water drain valve expansion tank water supply valve Y shape filter soft connect water pump cut-off valve soft connect Main modular Auxiliary modular1 Auxiliary modular kcalh water flow switch auxilary heater pressure gauge Cooling input Heating input water drain valve connet PCB box of O# unit thermometer 80V N~ 50Hz Fan coil Control type ire control. Safety protection device Main module + auxiliary module Highlow-pressure switch, anti-frost switch, water-flow switch, over-load protection, and power phases sequence protection Sketch of 00kw module connection Single module: ater flow switch Compressor input Refrigerant Refrigerant R ater pump(main) Bleeder pipe Bleeder supplier Cutoff valve ater flow volume m h ater drain valve ater resistance loss kpa 15 ater pump (auxiliary) ater inlet Check valve Adjusting valve ater system aterside heatexchanger Max. Pressure MPa Shell-and-tube, high efficiency heat-exchanger 1.0 Flow gauge Filter Themometer Air side heat-exchanger Dimension Total weight Packing Optional auxiliary heater ater inletoutlet pipeline diameter Type Air flow volume 10 m h Fan motor input L H kw x x1 790 Fin coil Notes: 1. Each module is packed separately and the packing size refers to one module only.. Auxiliary electric heaters are not provided. If necessary the users may refer to the above tables parameter about auxiliary electric heater and configure themselves.. Nominal capacities are based on the following conditions: Cooling condition: chilled water inletoutlet: 1 O C7 O C. Outdoor temp:5 O C(DB)4 O C(B) Heating condition: warm water inletoutlet: 40 O C45 O C. Outdoor temp:7 O C(DB)6 O C(B) 4. ater side fouling factor: 0.086m. O Ckw x L x x H (450 x 50 x 700) x x x x x Module ater outlet Multi modules (we recoend the following two types:) No.8 Module Evaporator ater pump A No.1 Module(main) ater pipe Evaporator Temp.sensor of total water outlet ater flow switch No.8 Module Evaporator ater pump No.1 Module(main) B Evaporator ater pipe Pressure gauge Soft connector ater pump Expansion tank Temp.sensor of total water outlet ater flow switch 1. For the 0kw and 65kw system, if electrical two-way valve used for all terminals and they are all closed when main unit is operating, the plate exchanger may be damaged. So pass-by adjusting valve should be set in the system.. If there is no any pass-by adjusting valve in the system, the number of fan coil with two-way water valve should not over 50%. 4 44

24 ater-cooled Package Unit Features The system adopt compliance scroll compressor with high efficiency, low noise level, stable performance & high reliability. [ ] Series Adopt advanced parallel system just as multi system, each compressor will run according to the load of the system. It can save a lot of energy when operation at partial load; Shell-tube condenser efficiently reduces the water jam and makes it easier to do clearance of water system; Microcomputer control technology makes the water pump and cooling tower can be easily controlled; The touch screen make it is easy to operation; The kinds of protection function makes the system safety and rhathymia; The strong protection and malfunction detect makes the system easy for debugging and maintenance; Polyester treatment technics, makes the beautiful appearance and good anti- erode ability; ater-cooled Package Unit MGP-F5S MGP-F60S MGP-F80S MGP-F100S~MGP-F145S Refrigerant: R, R407C Apply site: Factory, supermarket, restaurant, multiple shop and recreation. Capacity range:

25 ater-cooled Package Unit Dimension Specification Touch screen Pressure gauge Installation hole(4-15) F G Face H Filter Condenser drainage Backside 585 Cooling capacity Rated power EER Rated current A Type Start-up mode Compressor Output power Lubricatin Standard goil L Type Refrigeration MGP-F5S x 1.8x 8x1 MGP-F60S x4 1.8x4 8x MGP-F80S x4 1.8x4 9x MGP-F100S V,N~50Hz Scroll Direct start-up.05x6 Mineral oil 1.8x6 R 8x MGP-F10S x.0x 9.0x MGP-F15S x.x 9.5x MGP-F145S x.x 9.5x Cooling water outlet Cooling water inlet Emergency drainage ind-wheel Motor Fan motor Driving mode Air volume m h Static pressure Pa ater Volume m h Strap Air outlet Left side Air outlet Cooling ater Side Outlet of evaporator ater resistance Diameter of inlet wate pipe Diameter of outlet wate pipe Pa inch inch inch (1-1") 40(1-1") 5(1") (-1") 65(-1") 5(1") (-1") 65(-1") 5(1") (-1") 65(-1") 5(1") (-1") 65(-1") 5(1") (-1") 65(-1") 5(1") (-1") 65(-1") 5(1") Outlet of plate inch 5(1") 5(1") 5(1") 5(1") 5(1") 5(1") 5(1") Height(beforeafter) length(beforeafter) width(beforeafter) NetCross weight Protection device Over-load protection, highlow pressure protection, anti-frost protection, and inner temp. Protection of compressor, phase-sequence Top side MGP-F100S MGP-F10S MGP-F15S MGP-F145S Top side MGP-F5S MGP-F60S MGP-F80S High pressure protection Low pressure protection Noise fcm fcm db(a) MGP-F5S MGP-F60S MGP-F80S MGP-F100S MGP-F10S MGP-F15S MGP-F145S Unit: A B C D E F G H

26 Overview of heating water system R407C R [ R ] Series Based on reverse Carnot cycle principle, heating water system is one of the most advanced water heater with the highest COP. Heating water system generally consists of compressor, evaporator, expansion valve, strainer, accumulator tank, condenser, water tank. Integrative The sketch of system connection Heating ater System Integrative Integrated design of main unit and Compressor High temperature Hot water tank makes it very conveniently using only by connecting the water inlet and outlet pipes. Air inlet Heat exchanger for air Heat exchanger for water ater tank Hot water Low temp. Expansion Valve Cool water 50

27 Heating ater System Environmental Protection Heating water system is environmentally friendly and low energy consuming. Installation sketch for single unit Economical Less additional operation charge; No need for transportation and storage of fuel; simple maintenance and reparation. COP up to 4.0. Heat pump water heater ater tank Drain valve Pressure meter Filter Pipe union ater pump Cutoff valve ater supply To user Safety Heating water system does not need storage of fuel and fuel pipe, therefore, it is free of fuel leakage, fire and explosion. The unit has multi-protection functions: high-pressure protection, low-pressure Installation sketch for multi units protection, overflow and overload protection for compressor, startup delay, water switch, water temperature overhigh protection and water level protection of water tank. Heat pump water heater Heat pump water heater Heat pump water heater Heat pump water heater Heat pump water heater Heat pump water heater Convenience ONOFF valve valve valve valve valve valve Automatic intelligent controlling system defrosts automatically in cold winter. valve valve valve valve valve valve Outdoor installation; no special equipment room needed. Durability Pipe choice Famous brand compressor and plate heat exchanger equipped. Quintuple antirust technique ensures excellent durability. Number of unit (set) 1~ 4~6 7~9 10~1 1~16 idely applicable ithin the temperature range from -10 to 40 0 C, the heating water system can Pipe diameter (inch) 1~ ~ ~ ~ ~4 work all year around, and perform well against bad weather. 51 5

28 Heating ater System Specification Heating capacity Rated power Rated current A Hot water volume m h Max power Max current A Specification, power supply Controlling method Compressor (power x quantity) Refrigerant Refrigerant charge Outlet water temp Heat exchanger(water side) Specification of Diameter,water inlet pipe water system Diameter,water outlet pipe Max compression resistance Type Heat exchanger Motor power (gas side) Type of air outlet Length Demension idth Height eight Noise level db(a) MGH-F5S MGH-F17.5S MGH-F9 MGH-F V N ~ 50HZ 0V 1N ~ 50HZ Manual,Auto and failure alarm 4.5 x 4.5 x 1. x x 1 RR407C 00g x 00g x 1 100g x g x 1 60 (default) stainless steel plate heat exchanger tube-tube heat exchanger DN5 DN5 1.0Mpa 50 x Vertical air discharge DN0 DN0 1.0Mpa DN15 DN15 1.0Mpa DN15 DN15 0.8Mpa innergroove copper pipe,hydrophilic aluminum coil 150 x Side air discharge Vertical air discharge Side air discharge [ S ] Series ater Source Heat Pump 5

29 ater Source Heat Pump HO TO READ THE MODELS? M S H - 1 S Power Supply S: 80V~, 50Hz, Ph V~, 50Hz, 1Ph System sketch map Save energy, environmental, healthy as the thematic of today's AC market, AC industry come into a new stage. The Midea split water source heat pump unit can meet more and more requirement of the thematic, and become the new start of AC industry Top floor Outdoor Unit Nominal Capacity: Vertical pipe Other heat source H: Heating And Cooling C: Cooling Only Horizontal pipe AC system ater Source Heat Pump N Floor Midea Copper pipe Copper pipe Copper pipe First floor Example: 1. Electronic ater handler. ater circle pump. Soft connector 4. valve 5. water filter 6. cooling tower 7. water expansion tank ater Circle Type Share the flow water in the water pipe as coolingheating source. It can adopt crude water source as river water, sea water, lake water, etc, even industry waste water or sewage can be adopted as the coolingheating source

30 ater Source Heat Pump Features Environmental-friendly and save energy Adopt the ground water, lake water, etc, do not ater source low static pressure duct pollute the environment. ater cooled type with high heat exchange ratio. It is very suitable for some place where requirement heating and cooling at the same time. Ultra thin body, space saving and easy installation. Quiet operation, low noise. Stable and reliable Simple system design, reliable performance. ater cooled heat exchange, high efficiency and stable operation. Easy enlarge the capacity, Save investment It can invest and install the system for some building by stages while do not affect the project design and save early days investment. Set aside water pipe connector on public water source, so that easy for enlarging the capacity. Various of indoor unit Power Supply Cooling Input Heating Noise level weight Indoor unit Connection Pipe Dimension Ari volume Gas Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration db(a) () D() H() m h DN() DN() MTA-18CR MTA-18HR V-50Hz R MTA-4CR MTA-4HR Various of indoor unit, flexible equipment selection. The system can be installed in covert place, do not affect the holistic layout of the building. Power Supply Cooling Input Heating Noise level weight Indoor unit Connection Pipe Dimension Ari volume Gas Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration db(a) () D() H() m h DN() DN() MTA-4CR MTA-4HR Cooling condition: Indoor temperature: 7 O C(DB)19 O C(B), water inlet temperature: 0 O C;. Heating condition: Indoor temperature: 0 O C(DB), water inlet temperature: 0 O C; MTA-4CR 1.0 R MTA-4HR V-50Hz-N MTA-48CR MTA-48HR

31 ater Source Heat Pump ater source four way cassette ater source high static pressure duct Installed in the ceiling, and save much sapce. Four directions and large scale of air flow, create a much more comfortable space. Quite high external static pressure, long distance air supply. Fresh air drawing, healthier and more comfortable for you. Power Supply Cooling Input Heating Noise level weight Indoor unit Connection Pipe Dimension Ari volume Gas Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration db(a) () D() H() m h DN() DN() MCA-18CR MCA-18HR V-50Hz R MCA-4CR MCA-4HR Power Supply Cooling Input Heating Noise level weight Indoor unit Connection Pipe Dimension Ari volume Gas Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration db(a) () D() H() m h DN() DN() MHA-18CR MHA-18HR V-50Hz R MHA-4CR MHA-4HR Power Supply Cooling Input Heating Noise level weight Indoor unit Connection Pipe Dimension Ari volume Gas Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration db(a) () D() H() m h DN() DN() MCA-4CR MCA-4HR Cooling condition: Indoor temperature: 7 O C(DB)19 O C(B), water inlet temperature: 0 O C;. Heating condition: Indoor temperature: 0 O C(DB), water inlet temperature: 0 O C; MCA-4CR 1.0 R MCA-4HR V-50Hz-N MCA-48CR MCA-48HR Power Supply Cooling Input Heating Noise level weight Indoor unit Connection Pipe Dimension Ari volume Gas Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration db(a) () D() H() m h DN() DN() MHA-4CR MHA-4HR Cooling condition: Indoor temperature: 7 O C(DB)19 O C(B), water inlet temperature: 0 O C;. Heating condition: Indoor temperature: 0 O C(DB), water inlet temperature: 0 O C; MHA-4CR 1.0 R MHA-4HR V-50Hz-N MHA-48CR MHA-48HR

32 ater Source Heat Pump Entire system design, easier installation and save spacing. High efficiency heat-exchanging,hence brings high EER. Anti-corrosive cabinet, stable running and long life-span. [ K ] Series Power Supply Cooling Input Heating ater Volume ater resistance Outdoor unit Noise level weight Dimension Connection Gas Pipe Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration Ls kpa db(a) () D() H() DN() DN() MSC MSH-5 MSC-7 MSH V-50Hz R Air Handling Unit Power Supply Cooling Input Heating ater Volume ater resistance Outdoor unit Noise level weight Dimension Connection Gas Pipe Pipe Liquid Pipe ater InletOutlet Pipe Condenser ater Pipe Refregeration Ls kpa db(a) () D() H() DN() DN() MSC-7S MSH-7S Cooling condition: Indoor temperature: 7 O C(DB)19 O C(B), water inlet temperature: 0 O C;. Heating condition: Indoor temperature: 0 O C(DB), water inlet temperature: 0 O C; MSC-1S R MSH-1S V-50Hz-N MSC-14S MSH-14S Fan Coil Unit 61

33 Air Handling Unit & Fan Coil Unit HO TO READ THE MODELS? Air Handling Unit M K A - 1 Z M Design sequence code Drawing off method of filter : up draw off Direction of pipe connection Z: Left connection Y: Right connection Supply air direction: type 1 Coil row quantity A: 4 rows B: 6 rows C: 8 rows Structure form of the unit : horizontal type Nominal airflow volume (x100m h) 1: Single-wall air handling unit : Duble-wall air handling unit Brief introduction Air Handling Unit Midea fan coil unit be made from high quality galvanization, the beautiful and thin body makes it save a lot of space and easy for installation. The big air volume makes a syetrical room temperature so do not get harm to people at the same time. The advanced technology and high quality material reduced the noise level, it is widely used in marketplace, hospital, office, hotel, airport, etc. Midea air handling unit have six series production as single wall horizontal type, single wall vertical type, single wall-mounted type, dual wall horizontal type, dual wall vertical type and dual wall-mounted type. Air flow volume ranges from 000m h to 00m h, cooling capacity ranges from 6 to 985, heating capacity ranges from 11 to Midea air handling unit has been tested by national AC quality supervise testing center, as low noise level, high efficiency, stable operation and low power consumption make it as the advanced production in the world, and it is recoended for users by CRAA (China Refrigeration And Air-Conditioner Industry Association). As room AC, It is widely used in hotel, showplace, marketplace, office room, etc.; as industrial AC, it can meet the requirement of electron, chemical plant, medical treatment, pharmacy, tobacco produce, food produce, etc. K series Air Handling Unit Midea Fan Coil Unit M K A - 00 Nominal airflow volume (CFM) A: Four way cassette type B: Compact four way cassette C: One way cassette F1: Concealed floor standing F: Expoded floor standing K series Fan Coil Unit Midea 6 64

34 Air Handling Unit Fan Coil Unit Single wall horizontal type Air handle volume: 000~0000m h Four way cassette(compact) Cooling capacity: 1~45 Heating capacity: 18~70 Single wall vertical type AHU Air handle volume: 000~0000m h Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKB x45x x40x MKB x45x x40x MKB x45x x40x MKB x45x x40x Cooling capacity: 1~45 Heating capacity: 18~70 Four way cassette Dual wall horizontal type Air handle volume: 000~00m h Cooling capacity: 1~985 Heating capacity: 18~1100 Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKA x10x90 100x0x MKA x10x90 100x0x MKA x10x90 100x0x MKA x10x90 100x0x MKA x10x90 100x0x MKA x10x90 100x0x Dual wall vertical type Air handle volume: 000~00m h Cooling capacity: 1~985 Heating capacity: 18~1100 One way cassette all-mounted type Air handle volume: 1500~5000m h Cooling capacity: 6~60 Heating capacity: 11~90 Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKC x5x x10x The above design and specifications are subject to change without prior notice for product improvement..the values given in the table for the noise level reflect the levels in anechoic chamber. MKC x5x x10x460 7 MKC x198x x65x

35 Fan Coil Unit Exposed floor standing Duct type Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKF x5x66 105x85x810 7 MKF x5x66 105x85x810 7 MKF x5x x85x MKF x5x x85x MKF x5x66 15x85x Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKT x40x x40x MKT x40x x40x MKT x40x x40x MKT x40x x40x MKT x40x x40x Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKF x5x66 15x85x MKF x5x x85x The above design and specifications are subject to change without prior notice for product improvement..the values given in the table for the noise level reflect the levels in anechoic chamber. MKF x5x x85x MKF x5x x85x Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKT x40x x40x MKT x40x x40x MKT x40x x40x The above design and specifications are subject to change without prior notice for product improvement..the values given in the table for the noise level reflect the levels in anechoic chamber. MKT x40x489 10x40x MKT x40x489 10x40x MKT x67x x81x Concealed floor standing Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKF x1x545 65x65x MKF x1x545 65x65x MKF x1x545 85x65x MKF x1x545 85x65x MKF x1x x65x Air volume ater flow ater resistance Noise level Net dimension Packing dimension Net weight Gross weight CFM m h LPH kpa db(a) (xhxd) (xhxd) MKF x1x x65x MKF x1x545 15x65x The above design and specifications are subject to change without prior notice for product improvement..the values given in the table for the noise level reflect the levels in anechoic chamber. MKF x1x545 15x65x MKF x1x545 15x65x

36 Accessories Accessorial electric heater Accessories SDS Series Production feature Adopt high efficiency electric heater, syetrically heat; It is tested under 10bar water pressure, high security; Small body with high removability, easy for load; It can be customized just according to customer's requirement. A C D E E B C D Dimension () SDS-15S-A SDS-18S-A SDS-7S-A SDS-0S-A SDS-45S-A SDS-54S-A SDS-60S-A SDS-7S-A SDS-75S-A SDS-90S-A SDS-100S-A SDS-10S-A SDS-144S-A SDS-150S-A SDS-175S-A SDS-180S-A SDS-00S-A Voltage(V) 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V 80V Input() 15K 18K 7K 0K 45K 54K 60K 7K 75K 90K 100K 10K 144K 150K 175K 180K 00K A B C D Remark: The accessorial electric heater should be additional ordered. E

37 Accessories SDH Series Production feature Stainless steel structure, and filled in insulating material between the shell and electric heat pipe, and also has high anti-erode capability. Adopt famous temperature controller can avoid destroy the components. Adopt high efficiency electric heater, syetrically heat. aterproof cover Cover Shell ater outlet ater inlet Electric heater pipe Inner flue Heat preservation layer ire outlet Fixed hole Drainage valve SDH--A SDH--A SDH-4-A SDH-5-A SDH-6-A SDH-7S-A SDH-8S-A SDH-9S-A SDH-10S-A SDH-1S-A SDH-15S-A SDH-0S-A Voltage (V) Input () Total length() Diameter() *158 *190 Remark: The accessorial electric heater should be additional ordered. ater inletoutlet 1.5'' 1.5'' 71

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview Product overview 1 Company Profile Yantai Oceanair Refrigeration & Air-Conditioning Co.,Ltd. was established in 2004 and has been listed on the New OTCBB (Stock Code: 831870). We are mainly specialized

More information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: , DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded

More information

Water-cooled Centrifugal Chiller

Water-cooled Centrifugal Chiller KMC Series Water-cooled Centrifugal Chiller 1795-4923kW(500RT-1400RT) R-134a Contents Nomenclature... 1 Unit features... 1 Computerized control... 3 General technical data... 4 Electrical data... 6 Dimension

More information

3 0 H X C A - H P 2

3 0 H X C A - H P 2 3 0 H X C 1 3 0 A - H P 2 Max. Leaving Water Temperature (Heating Mode) 1 for 47 O C,2 for 60 O C Water-to-Water Screw Heat Pump 3 rd Generation Global Water Cooled Chiller Norminal Capacity (USRT) Carrier

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw Water-to-water Screw Heat Punp Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies Corp. (UTC), which

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

Commercial Air Conditioners 2017/2018

Commercial Air Conditioners 2017/2018 Coercial ir Conditioners 207/208 Water Cooled Screw Chiller Flooded type 340-780kW (R34a) Midea CC Midea CC is a key division of the Midea Group, a leading producer of consumer appliances and provider

More information

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by: Johnson Controls - Hitachi Air Conditioning Manufactured by: Johnson Controls-Hitachi Wanbao Air Conditioning (Guangzhou) Co.,Ltd. Address:No.110.ChengAo East Road, Conghua,Guangzhou City, Guangdong Province,China

More information

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY MHS-F HR-2011 SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY MODEL: MCS050.1-380.2FSP MHS050.1-380.2FSP MHS050.1-235.2FSR COOLING CAPACITY: 164KW-1370KW HEATING CAPACITY: 172KW-1439KW PARTIAL HEAT RECOVERY:

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

DAIKIN Huizhou Factory Profile

DAIKIN Huizhou Factory Profile DAIKIN Huizhou Factory Profile DAIKIN AIR-CONDITIONING (SHANGHAI)CO.,LTD HUIZHOU FACTORY The manufacture base of central air-conditioner in China Established Daikin group, a wholly owned subsidiary Amalgamated

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Air Cooled Scroll Chiller / Heat Pump

Air Cooled Scroll Chiller / Heat Pump Air Cooled Scroll Chiller / Heat Pump SRA 145 Nominal Capacity 67.5 to 1080 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data R407c 5 Physical Data R134a 6 Unit Performance

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

SCA 620C AIR COOLED SCREW CHILLER

SCA 620C AIR COOLED SCREW CHILLER DUNNAIR I N T E R N A T I O N A L L I M I T E D SCA 620C AIR COOLED SCREW CHILLER MV6 CONTROL Refrigerant: R22 Standard NOMINAL CAPACITY 620 kw(r) DUNNAIR INTERNATIONAL LIMITED Subject to change without

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

Screw Water Cooled Chiller SCW210

Screw Water Cooled Chiller SCW210 Screw Water Cooled Chiller SCW210 Nominal Cooling Capacity 185.1 to1480.8 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

Leadership, Innovation, Advanced Technology Synergise Here!

Leadership, Innovation, Advanced Technology Synergise Here! Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified

More information

CASE STUDY AIR-CONDITIONERS

CASE STUDY AIR-CONDITIONERS CASE STUDY AIR-CONDITIONERS An Investment in Longer Lasting Quality ABOUT US BT Commercial Ltd. is a dynamic and diversified company, which has been in operation since 1992. Our company, which is growing

More information

Hitachi Centrifugal Chillers

Hitachi Centrifugal Chillers Featuring Ozone-safe HCF134a Hitachi Centrifugal Chillers HC-F-GXG Higher-efficiency Type ARI temperature condition JIS temperature condition 1,463 kw to 4,571 kw (416 USRT to 1, USRT) 1,407 kw to 4,395

More information

Scroll Water Cooled Chiller

Scroll Water Cooled Chiller Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

LG HVAC SOLUTION AIR COOLED SCROLL CHILLER

LG HVAC SOLUTION AIR COOLED SCROLL CHILLER LG HVAC SOLUTION AIR COOLED SCROLL CHILLER Nomenclature Factory Refrigerant: U: China, R410A Cooling Type: A: Air cooled C/O H: Air cooled H/P Capacity: [Air Cooled C/O & H/P ] Unit: 020 : 20RT Line up:

More information

Compact design & easy maintenance

Compact design & easy maintenance Compact design & easy maintenance 18 SEER MRCOOL Address: 1315 College Street Clarksville TN 37040 Email: sales@mrcool.com mrcool.com Specifications and appearance are subject to change without notice.

More information

Midea VFD Centrifugal Chiller Technology

Midea VFD Centrifugal Chiller Technology Midea VFD Centrifugal Chiller Technology Content Why VFD VFD centrifugal chiller technology Solution 2 HVAC major issues Energy conservation Global warming reduction 3 Why VFD No Compressor A/C Lower GWP

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

COMMERCIAL AIR CONDITIONERS M Type Air Cooled Screw Chiller 2012

COMMERCIAL AIR CONDITIONERS M Type Air Cooled Screw Chiller 2012 MCAC-2012-39 COMMERCIAL AIR CONDITIONERS 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner department,

More information

OIL FREE CENTRIFUGAL CHILLER

OIL FREE CENTRIFUGAL CHILLER OIL FREE CENTRIFUGL CHILLER OIL FREE CENTRIFUGL CHILLER High Efficiency Energy saving and high efficiency The unit adopts the turbo inverter compressor technology and frictionless technology, which will

More information

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

INVERTER SCROLL. LG Electronics     Distributed by. Copyright 2017 LG Electronics. All rights reserved. LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /

More information

High-efficiency Turbo Chiller (NART Series)

High-efficiency Turbo Chiller (NART Series) 67 High-efficiency Turbo Chiller (NART Series) Wataru Seki* 1 Kenji Ueda* 1 Jyou Masutani* 2 Yoichirou Iritani* 2 Turbo chillers are widely used for district heating and cooling, heat storage (regeneration)

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

Modular Water Cooled Water Chiller

Modular Water Cooled Water Chiller Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd. Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

EN aquatech.piovan.com

EN aquatech.piovan.com EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.

More information

WATE R -C OOLE D WATE R C H ILLE R S

WATE R -C OOLE D WATE R C H ILLE R S WATE R -C OOLE D WATE R C H ILLE R S R40A / R407C / R Standard Type Heat Recovery Type Brine Type ISO 900 ISO 400 Printed in Japan (H) HR-E590S Sep. 0 Water-cooled Chillers Advanced air conditioning solutions

More information

High COP. Water-Cooled Screw Chiller

High COP. Water-Cooled Screw Chiller High COP Water-Cooled Screw Chiller 3 4-7 9 High COP The units are water-cooled chillers, designed from the ground up to meet the needs of today and tomorrow. It is distinguished for its chlorine-free

More information

Midea R134a 50Hz l Flooded type water cooled screw chiller (PCB Control)

Midea R134a 50Hz l Flooded type water cooled screw chiller (PCB Control) DM15-01.01.18en Midea R134a 50Hz l Flooded type water cooled screw chiller (PCB Control) Applicable Model: MWSC340A-FB3 MWSC440A-FB3 MWSC540A-FB3 MWSC690A-FB3 MWSC805A-FB3 MWSC890A-FB3 MWSC1080A-FB3 MWSC1200A-FB3

More information

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics     Distributed by 4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by FEATURES & BENEFITS High Efficient Inverter Technologies

More information

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd.

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd. Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller Content Introduction 1 Features...1

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview Product overview 1 Company Profile Yantai Oceanair Refrigeration & Air-Conditioning Co.,Ltd. was established in 2004 and has been listed on the New OTCBB (Stock Code: 831870). We are mainly specialized

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA... FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN

More information

MAC-A R410A Series Air cooled Modular Chiller

MAC-A R410A Series Air cooled Modular Chiller Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,

More information

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER BIGGER-H SERIES JIAXING MES NEW ENERGY TECHNOLOGY CO.,LTD. High quality- We believe that quality is the best business plan R&D team- Professional R&D

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

ERACS.C-N Higher efficiency air-cooled screw pump

ERACS.C-N Higher efficiency air-cooled screw pump ELITE TM Series COOLING ERACS.C-N Higher efficiency air-cooled screw pump HEATING HOT WATER Cooling Capacity:5~1341 (7~381 Tons) Heating Capacity:60~1363 (74~388 Tons) High Efficiency Air-cooled Heat Pump

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

HERO SERIES-DC INVERTER HEAT PUMPS

HERO SERIES-DC INVERTER HEAT PUMPS HERO SERIES-DC INVERTER HEAT PUMPS PHNIX DC inverter heat pump can work efficiently with floor heating, water fan coils or radiators for heatingcooling. WATER FAN COILS DC INVERTER HEAT PUMP FLOOR HEATING

More information

"Apollo" series High-efficiency screw-type air-cooled chilled water (heat pump) unit

Apollo series High-efficiency screw-type air-cooled chilled water (heat pump) unit Give life to building, bring us back to nature "Apollo" series High-efficiency screw-type air-cooled "Apollo" series High-efficiency screw-type air-cooled R134a series: EKAS065 EKAS400 Company Profile

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

Flexible. The. Chillers

Flexible. The. Chillers MFCA FreeControl Variable Frequency Modular Heat Pump Energy Saving & High Efficiency Flexible & Reliable Environment Friendly The Creatorr and Leader of Modular Chillers Contents What is MFCA Features

More information

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M 1. MODELS LIST 1. NOMENCLATURE 3 3. FEATURES 3 4. PRODUCT DATA 6 5. PERFORMANCE CORRECTION 9 6. ANTIFREEZE 1 7. INSTALLATION 13 8. ELECTRICAL DATA 16 9. ELECTRICAL DIAGRAM 17 10. SCHEMATIC WIRING DIAGRAM

More information

Technical Service Manual

Technical Service Manual Technical Service Manual Water-cooled Screw Chiller Model: Commercial Air Conditioner Division Midea Group Address: Midea Headquarters Building, 6 Midea Avenue, Beijiao, Shunde, Foshan, Midea CAC After-service

More information

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded

More information

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e. ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial

More information

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller ENERSAVE Hydrocarbon Scroll Water Cooled Chiller Your Green Input to Chiller ever found in the market To eliminate the threat of environmental impact by utilizing environmental friendly refrigerant gas-

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

Chilled Water Precision Air Conditioner for Critical Application

Chilled Water Precision Air Conditioner for Critical Application AIRSYS-P-SC-OPTIMA-HD-E14507V01.3 HD Chilled Water Precision Air Conditioner for Critical Application Cooling Capacity: 42.1kW~180.9kW OPTIMA product family is designed for medium to large data center.

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT GLOBAL CHILLER TM LIQUID CHILLER 30HX IN HARMONY WITH THE ENVIRONMENT GLOBAL CHILLER 30HX ADVANCED ULTIMATE RELIABILITY COMPACT SIZE - HIGH PERFORMANCE PRO More than 50000 Carrier screw compressors sold

More information

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08 MSRW MINI SERIES Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08 Contents FEATURES 1 C1 CONTROL 4 PHYSICAL DATA 5 UNIT CAPACITY 7 CHILLER SELECTION

More information

All DC Inverter Multi VRF

All DC Inverter Multi VRF All DC Inverter Multi VRF In 2012, Gree highly promoted GMV5 All DC Inverter Multi VRF New breakthrough in comfort ability, intelligent control and design. Eight prominent advantages More powerful product

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

Air-cooled modular Chiller. Nick Technical Engineer

Air-cooled modular Chiller. Nick Technical Engineer Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3

More information

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation EN Customers. The core of our innovation Feeding&Conveying Drying Dosing Temperature Control Refrigeration Granulation scroll-compressor chillers The scroll compressor is the most suitable component for

More information

Technical Development Program

Technical Development Program Technical Development Program COMMERCIAL HVAC CHILLER EQUIPMENT Water-Cooled Chillers PRESENTED BY: Omar Rojas Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

MTW Series Modular Oil Free Centrifugal Chillers

MTW Series Modular Oil Free Centrifugal Chillers TW Series odular Oil Free Centrifugal Chillers Cooling Capacity:300-2890kW odular Chiller agnetic Levitating Centrifugal Compressor Stainless Steel PHE Refrigerant R134A ax. COP: 12w/w TW Series odular

More information

Development of centrifugal chiller and heat pump using low GWP refrigerant

Development of centrifugal chiller and heat pump using low GWP refrigerant Development of centrifugal chiller and heat pump using low GWP refrigerant Ryosuke Suemitsu 1*, Naoya Miyoshi 1, Yasushi Hasegawa 1, Kazuki Wajima 1, Yoshinori Shirakata 1, Kenji Ueda 1 1 Mitsubushi Heavy

More information

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113 tu 137 IR COOLED Liquid chiller equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel CONDENSING coils 280 1500 kw Energy Class More efficient

More information

Koolman Air-Coolded Water Chiller With Heat Pump Option

Koolman Air-Coolded Water Chiller With Heat Pump Option Koolman Air-Coolded Water Chiller With Heat Pump Option CGAK/R 030-150 9.8~39 kw PKGP-PRC006-EN Contents Features and Benefits 4 Mechanical Specifications 5 Model Nomenclature 6 Performance Data 7 Dimensions

More information

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment

More information