and Refrigerant Identifier
|
|
- Austin Collins
- 5 years ago
- Views:
Transcription
1 Contaminated Refrigerant and Refrigerant Identifier
2 What is contaminated refrigerant? Two or many type of refrigerants mixed in the cylinder or Refrigeration and air-conditioning system knowingly or unknowingly Contaminated refrigerant is different from refrigerant blends. Contaminated refrigerant is sub-standard blends, which has negative effects to the system. Refrigerant blends are mixtures of refrigerants that have been formulated to provide a match to certain properties of the refrigerants originally used. These blends have been researched and developed by the manufacturers.
3 Effect of contaminated Refrigerant to the R & AC System Damage R & AC system; Reduce cooling capacity and consume more electrical energy and reduce efficiency system; Explosion may occur.
4 Case of counterfeit refrigerant Known composition of counterfeit R134a refrigerant: 60 % R22 monochlorodifluoromethane (+ R30, R142b traces) 40 % R40 methyl chloride Seen containers: Standard refrigerant bottles 13.6 kg (counterfeit on the right) ATTENTION: Don t expose to sunshine! May evolve high vapor pressure!
5 First Reefer Cases in Vietnam Chapter 12 Two different reefers in Asia Catastrophic explosions Suspicions as to the cause
6 Case in North America Chapter 12 Terminal engineer reported gas combusting in contact with air Concluded it must be an alkyl metal halide Finally managed to get a sample to a laboratory
7 Case in South America Chapter 12 Catastrophic explosion during maintenance Similar damage to those in Asia Sludge No sign of aluminum components White powder, alumina smoke residue
8 Fake refrigerants
9 Reasons for why R40 mixtures are in market? Price of HFCs has recently increased by 50%, meaning more reasons to fake HFC refrigerants Potential excess HCFCs in the market
10 Refrigerant Analysis Chapter 12 Pressure/Temperature Relationship Infrared Specific Identifier Infrared Component Analyzer Gas Chromatograph Mass Spectrometer
11 Infrared Specific Identifier R12, R134a, R22, HC
12 Infrared Component Identifier Chapter 12
13 Principle of Operation Chapter 12 Non Dispersive Infra Red Single detector with multi channel filter wheel Includes VAC power supply Low pressure vapor refrigerant sample or high pressure liquid sample using the supplied flash chamber. Accuracy: Better than +/- 2% Displays refrigerant components and their corresponding percentages.
14 Operation - Cautions and warnings NEVER obstruct the air intake, sample exhaust or cease vent ports of the instrument during use. X
15 Operation - Cautions and warnings Always verify that the refrigerant to be tested does not contain or will not emit heavy loads of oil or liquid. VAPOR SAMPLES ONLY! Introducing liquid refrigerant will CAUSE SERIOUS DAMAGE to the identifier Refrigerant (Liquid) OIL
16 Operation - Cautions and warnings DO NOT utilize any other hose other than those supplied with the instrument. The use of other hose types will introduce errors into the refrigerant analysis. Incorrect Result
17 Guide to Service Technician: Do not use contaminated refrigerant and ask the supplier to change that. Inform the appropriate authority from where you purchased the contaminated refrigerant. Contact National Ozone Unit for further guidelines.
Which Refrigerant Analyzer do I have? Ultima ID Model RI-2004HV Series
Which Refrigerant Analyzer do I have? 1. Neutronics has manufactured many different Refrigerant Analyzers over the past 25 years. They manufacture these analyzers as Neutronics branded products and also
More informationDiscovR R134a Refrigerant Identifier
Model 16009 DiscovR R134a Refrigerant Identifier Operating Manual Table of Contents Safety Precautions... 1 Description... 4 Operating Instructions.... 5 Fault Codes.... 7 Troubleshooting... 7 Replacement
More informationAUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941
AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL Analyzer Part Number: 68941 Table of Contents FOR YOUR SAFETY:... 3 IDENTIFIER WARNINGS/GENERAL CAUTIONS... 3 WELCOME... 5 1 INTRODUCTION AND OVERVIEW...
More informationULTIMA ID PRO OPERATION MANUAL. Analyzer Part Number: 69HVAC -PRO2
ULTIMA ID PRO OPERATION MANUAL Analyzer Part Number: 69HVAC -PRO2 Table of Contents TABLE OF CONTENTS V FOR YOUR SAFETY VI ANALYZER WARNINGS VI GENERAL CAUTIONS VII WELCOME VIII 1 INTRODUCTION AND OVERVIEW
More informationVacuum Gauge. Measures lower-than-atmospheric pressure Digital scales. microns psi in. Hg millibars pascals torr millitorr
Vacuum Gauge Measures lower-than-atmospheric pressure Digital scales microns psi in. Hg millibars pascals torr millitorr (Sealed Unit Parts Co., Inc.) Compound Gauge Measures pressure and vacuum Low-side
More informationRefrigerated Cylinder Testing Procedures
Refrigerated Cylinder Testing Procedures Presented by: Mike Baldwin Chairman of Depot Division President and CEO of ConGlobal Industries 28 March 2012 1 Halide Flame Testing of New/Recycled Refrigerated
More informationNEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL
NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page
More informationA: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.
1/1/12 RS-45 (R434A): Q & A 1 Q: What is RS-44? 1.Q: What is RS-45 A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-45 contain? A: RS-45 is
More informationIssue Paper Refrigerated Container (Reefer) Explosion
Issue Paper Refrigerated Container (Reefer) Explosion Background On 18 October 2011, Maersk Line informed the World Shipping Council s Safe Transport of Containers Working Group that it had recently experienced
More informationThe Dedicated Refrigerant Identifier
The Dedicated Refrigerant Identifier User s Instruction Manual ZEEAC311A by Table of Contents I. CAUTIONS & WARNINGS...3 II. FUNCTIONAL DESCRIPTION...4 III. HARDWARE DESCRIPTION...5 A. Enclosure Case...5
More information"World Class Quality" ULT/MA ID- HVAC REFRIGERANT IDENTIFIER OPERATION MANUAL
"World Class Quality" ULT/MA ID- HVAC REFRIGERANT IDENTIFIER OPERATION MANUAL Manual File ECO 8291 Revised: August 28, 2007 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431
More informationThe Portable Refrigerant Diagnostic Tool
The Portable Refrigerant Diagnostic Tool User s Instruction Manual P.N.: 5-06-7000-18-0 Manufactured by 456 Creamery Way Exton, PA 19341 610-524-8800 610-524-8807 (f) WWW.Neutronicsinc.com Table of Contents
More informationRLD-H10G Refrigerant Leak Detectors
FANs 125, 121 Product/Technical Bulletin RLD-H10G Issue Date 0396 RLD-H10G Refrigerant Leak Detectors The RLD-H10G is a professional grade leak detector for use by refrigeration and air conditioning technicians.
More informationOperation and Maintenance
Operation and Maintenance Instruction Manual 2100-9001 Rev. 3 June 2014 Product Leadership Training Service Reliability WARRANTY Bacharach, Inc. warrants to Buyer that at the time of delivery this Product
More informationACTIVATE BEFORE FIRST TEST
ACTIVATE BEFORE FIRST TEST www.refrigerantid.com/activate Thank you for purchasing the Ultima ID Pro Activating your product registration will enable us to send you software updates, periodic notification
More informationPublication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration
More informationChapter 2. Alternatives to HCFCs and their Characteristics
Alternatives to HCFCs and their Characteristics Refrigerant - General Chemical used in a cooling system, such as an air conditioner or refrigerator, as the heat carrier which changes from vapour to liquid
More informationUser s Information Manual
User s Information Manual CONDENSING GAS BOILER 220/299/300/399 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationDue to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.
TECHNICAL DATA SHEET R434A () Features and uses of R-434A () is a non-flammable HFC mixture. ODP = 0, compatible with traditional mineral lubricants, alkyl benzene and also with synthetic POE, so there
More informationRLD-H10P Refrigerant Leak Detector
FANs 125, 121 Product/Technical Bulletin RLD-H10P Issue Date 0396 RLD-H10P Refrigerant Leak Detector The RLD-H10P is a professional grade leak detector for use by refrigeration and air conditioning technicians.
More informationUse of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning
Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning This initiative was developed by: Content and guidance kindly provided by the following organisations: Cool Drive CPS Asia Pacific
More informationRS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:
TECHNICAL DATA SHEET Features and uses of is a non-azeotropic blend of HFC with zero Ozone Depletion Potential et low Global Warming Potential (GWP), formulated to meet the requirements of the F-Gas Regulation
More informationFACT SHEET 9 Large Air-Conditioning (air-to-air)
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Material on HFC Management Fact Sheets on HFCs and Low GWP Alternatives October 205 FACT SHEET 9 Large Air-Conditioning (air-to-air). Description
More informationR-407A R-448A R-449A
GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants
More informationAqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water
Aqua Balance WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water User s Information Manual * Low Lead Content If the information in this manual is not followed exactly, a fire
More informationAdditional users operating manual
Additional users operating manual For use with A2L Refrigerants e.g. R32, 1234yf, 143a, 1234ze This additional manual is valid for the following Promax Refrigerant Recovery Units: MiniMax-E; RG 5410A-E,
More informationBrand Assurance Anti-Counterfeiting Global Initiative
Brand Assurance Anti-Counterfeiting Global Initiative WIPO-UN-ESCAP-UNEP Bangkok, November 21-22, 2013 T. S. Kim DuPont Fluorochemicals, Asia Pacific 1 Refrigerants: The industry has an issue Counterfeit
More informationUnder Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:
Overview Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that: Require service practices that maximize recycling of ozone-depleting compounds (both chlorofluorocarbons
More informationMC Series Gas-Fired Heating Appliance
MC Series Gas-Fired Heating Appliance USER S INFORMATION MANUAL MC Series Models MC50 / MC80 MC99 / MC120 NOTICE: HTP reserves the right to make product changes or updates without notice and will not be
More informationSection 1: Theory of Heat Unit 3: Refrigeration and Refrigerants
Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants Unit Objectives After studying this chapter, you should be able to: Discuss applications for high-, medium-, and low temperature refrigeration.
More informationThe Inspector Automotive Refrigerant Identifier Part Number:
The Inspector Automotive Refrigerant Identifier Part Number: 7-08-1000-13-0 Neutronics Incorporated * 456 Creamery Way * Exton, PA 19341 * Phone: (610) 524-8800 * FAX: (610) 524-8807 Page 1 Table of Contents
More informationElite. User s Information Manual. Elite and Elite VWH* All Models
Elite User s Information Manual Elite and Elite VWH* All Models Heat Exchanger Bears the ASME H Stamp IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING
More informationUser s Information Manual
User s Information Manual Series 2 Models 1000-2000 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing
More informationWarranty Registration
WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationUser s Information Manual
User s Information Manual Series 3 Models 550 and 750 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing
More informationUser s Information Manual
User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
More informationPOWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings
POWDER GUIDE From ASIAN PAINTS (I) LTD Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings Section A : Powder Application Problems Trouble Possible Causes Solutions 1. Poor charging
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN
More information1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.
1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4. INSTALLATION OF THE INDOOR UNIT 5. CONDENSATE HOSE CONNECTION
More informationUser s Information Manual
User s Information Manual Gas-fired water boilers Series 4 Featuring Flexibility Series 4 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage,
More informationCLI Refrigerant Gas Leak Detector. User s Guide
el-520 CLI20204 Refrigerant Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-520 Refrigerant Gas Leak Detector, the most technologically advanced of its kind. The el-520
More informationGOLD. User s Information Manual. Water Boiler Series 4
GV Water Boiler Series 4 User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Do
More informationSafe Operation Manual. Honeywell IQ Force Gas Detector
Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96
More informationHVACR Refrigeration
Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction
More informationChecklist For Building Inspection & Fire Safety
INSPECTION CHECKLIST Date of Inspection: Location/Address: Weather Condition: Inspector: AFTER COMPLETING YOUR INSPECTION, TRANSFER YOUR CONCERNS/OBSERVATIONS TO THIS AREA Facility: Name: Staff Contact:
More informationYELLOW JACKET. Refrigerant Identifier OPERATION MANUAL. Part Numbers: Manufactured by:
YELLOW JACKET Refrigerant Identifier OPERATION MANUAL Part Numbers: 68945 68947 68948 Manufactured by: 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationFACT SHEET 9 Large Air-Conditioning (air-to-air)
FACT SHEET 9 Large Air-Conditioning (air-to-air) UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material for on HFC HFC Workshop, management: 205 technical issues Bangkok, 20 and 2 April
More informationReference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.
GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant
More informationUser s Information Manual
Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s
More informationD-TEK Select. Refrigerant Leak Detector
O P E R A T I N G M A N U A L D-TEK Select Refrigerant Leak Detector DECLARATION OF CONFORMITY This is to certify that this equipment, designed and manufactured by INFICON Inc., Two Technology Place, East
More informationAn FT-NIR Primer. NR800-A-006
Industry: Product: Oils and Gas NR800 Near Infra-red Spectroscopy Like other forms of spectroscopy, light from a lamp (usually called the source ) is passed through a sample and measured by a detector.
More informationAPPLICATION & SERVICE GUIDE
APPLICATION & SERVICE GUIDE HFC Refrigerant R410a Used In GeoMax2 Geothermal Heat Pump Systems Although the bulk of this manual is information regarding R410a, R407c will also be discussed for purposes
More informationP.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces
P.O. Box 799900, Dallas, TX 75379-9900 USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals,
More informationKSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector
Issue 1 KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR Installation Manual Instructions for :- For safe and correct use please read the installation manuals supplied with the equipment.
More informationENERSAVE Hydrocarbon Scroll Water Cooled Chiller
ENERSAVE Hydrocarbon Scroll Water Cooled Chiller Your Green Input to Chiller ever found in the market To eliminate the threat of environmental impact by utilizing environmental friendly refrigerant gas-
More informationGas Fired Residential Combi Boiler Floor and Wall Mount Models
Gas Fired Residential Combi Boiler Floor and Wall Mount Models USER S INFORMATION MANUAL Models WBRC**140W WBRC**199W WBRC**140F WBRC**199F ** NG Refers to Natural Gas Operation LP Refers to Propane Gas
More informationSERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY
Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not
More informationFisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual
Fisher Scientific Isotemp Muffle Furnace 550 Series Instruction Manual Model 14 Catalog No: 10-550-14 & 14A Model 58 Catalog No: 10-550-58 Model 126 Catalog No: 10-550-126 Service Division (Repairs):
More informationPresented by: Senior Vice President ConGlobal Industries May 1, 2012
Rfi Refrigerated tdclid Cylinder Testing Procedures Presented by: Rene Etcharren Senior Vice President ConGlobal Industries May 1, 2012 1 Halide Flame Testing of New/Recycled Refrigerated Gas from Cylinders
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationUser s Information Manual
User s Information Manual Gas-Fired Water Boilers With or without Aqua Logic (CWH) Now available Matching High Performance Companion Water Heater (Unit sold separately) If the information in this manual
More informationH-10PM. Refrigerant Leak Detector
H-10PM Refrigerant Leak Detector Congratulations! You have just purchased the most versatile, high performance service leak detector available in the industry today. It will detect refrigerants with a
More informationDesign Manual Installation Operation Maintenance
Design Manual Installation Operation Maintenance Model FT194 UV/IR Portable Flame Detector Test Lamp 23282 Mill Creek Drive, Suite 215 Laguna Hills, CA 92653 USA +1.949.583.1857 Phone +1.949.340.3343 Fax
More informationUser s Information Manual
TM User s Information Manual Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury
More informationOperating instructions
6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG
More information14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.
HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant
More informationFlammable and Combustible Liquids
Flammable and Combustible Liquids Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids requires the
More informationOperating Manual. Model CoolTech ID Refrigerant Identifier
Operating Manual ID Model 16900 CoolTech ID Refrigerant Identifier Table of Contents Safety Precautions............................... 2 Overview....................................... 4 Hardware Descriptions............................
More informationTankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRT**150 / WGRT**199 / WGRTC**199 **A suffix of LP denotes propane gas **A suffix of NG denotes natural gas NOTICE: Westinghouse reserves the right
More informationOperating Instructions and User s Information Manual VITOROND 200 WARNING WARNING IMPORTANT. Read and save these instructions for future reference.
Operating Instructions and User s Information Manual for use by heating contractor Vitorond 200 VD2/VD2A Series Oil- / Gas-fired boiler Heating input: 490 to 4387 MBH (144 to 1285 kw) VITOROND 200 If the
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL RLV-700 REFRIGERANT RECOVERY / RECYCLING UNIT (PATENTED) NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 (215) 638-8909 FAX (215) 638-9270 REVISED 03-21-2018
More informationModel gffoz Process Ozone Sensor (In-Line)
Date ECO# Rev Description Originator 9/15/97 1.0 First Publication DB 10/8/97 2.0 Miscelaneous corrections DB 10/28/97 3.0 Minor changes BM 5/1/98 3.1 Added CE compliance BM TM IN USA, INCORPORATED 87
More informationIR200 INFRARED HCFC & AMMONIA (NH3) REFRIGERANT SENSOR. User Manual
IR200 INFRARED HCFC & AMMONIA (NH3) REFRIGERANT SENSOR User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay
More informationOPERATION & MAINTENANCE MANUAL RHS680
OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup
More informationEFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:
Installation & Operating Manual EFC 211 Fan Control USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationEL195UH SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506597 01 11/2010 EL195UH SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,
More informationOWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series
OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE
More informationUniversal Fire Tube Boiler Wall Mount Models
Universal Fire Tube Boiler Wall Mount Models USER S INFORMATION MANUAL Models WBRU**80W / 100W / 120W / 140W / 175W / 199W **NG denotes Natural Gas Model, LP Denotes Propane Model Heat Exchanger Bears
More informationCaresaver Universal Refrigerant Recovery Unit
Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2
More informationCHAPTER 1 INTRODUCTION
CHAPTER 1 INTRODUCTION 1.1 CFC REFRIGERANTS Since the 1930s, chlorofluorocarbons (CFCs) have been widely used as foam blowing agents, aerosols and especially refrigerants due to their pre-eminent properties
More informationSERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11
SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume
More informationOperation Manual R205BV, R209BV
Operation Manual R205BV, R209BV 1 Safety Instruction The rotary evaporator is manufactured according to current methods and accepted safety regulations. However, risks still exist during the installation,
More information6. Within an internal combustion engine, the can-shaped component that moves up and down the cylinder
Student ID: 22133336 Exam: 986052RR - Heat When you have completed your exam and reviewed your answers, click Submit Exam. Answers will not be recorded until you hit Submit Exam. If you need to exit before
More informationTEK-Mate. Refrigerant Leak Detector
O P E R A T I N G M A N U A L TEK-Mate Refrigerant Leak Detector Declaration Of Conformity This is to certify that this equipment, designed and manufactured by INFICON Inc., 2 Technology Place, East Syracuse,
More informationREFRIGERANT CHANGEOVER
Date of last update: Dec-17 Ref: CC7.26.5/0117-1217/E Application Engineering Europe REFRIGERANT CHANGEOVER FROM HFC R134a TO HFC/HFO R450A & R513A WARNING Use only Emerson approved refrigerants and lubricants
More informationResponsible Care Product Stewardship for Refrigerants
1 ABSTRACT Responsible Care Product Stewardship for Refrigerants Christoph Meurer; Ewald Preisegger Solvay Fluor und Derivate GmbH Hans-Böckler-Allee 20 30161 Hannover Germany Product stewardship summarizes
More informationUser s Information Manual Models:
FB-USER Rev C User s Information Manual Models:1.5-5.0 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury
More informationResidential Gas Hybrid Water Heater
Residential Gas Hybrid Water Heater USER S INFORMATION MANUAL WGRGH20NG75F / WGRGH20NG76F / WGRGH20NG100F WGRGHNG75F / WGRGHNG76F / WGRGHNG100F Models* *A suffix of LP denotes propane gas NOTICE: Westinghouse
More informationM-20 Oil Mist Concentration Detection and Alarm Device
Guideline No.M-20 (201510) M-20 Oil Mist Concentration Detection and Alarm Device Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains
More informationHazardous Material Safety Program
Hazardous Material Safety Program Lithium Battery History and Testing Presented By: Date: Discussion Topics Challenges for mitigating lithium battery risks as technology advances What do we know from research
More informationUSER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater
USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater Contents Section Page Major Components... 2 1 About Our Manual... 2 2 Refractory Handling...
More informationModel C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments
Model C-380 Refrigerant Leak Detector Instruction Manual reedinstruments www 1-877-849-2127 info@reedinstruments. www.reedinstruments. Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument
More information