Instruction Manual. 500 Series Thermoelectric Gas Coolers

Size: px
Start display at page:

Download "Instruction Manual. 500 Series Thermoelectric Gas Coolers"

Transcription

1 Instruction Manual 500 Series Thermoelectric Gas oolers 5200 onvair Drive arson ity, NV Phone: Fax:

2 ontents Receiving and Storage 4 Definition of Symbols 5 Specifications 6 Description and Principle of Operation 8 Installation 11 Electrical onnections 12 Start-Up 18 Shutdown 18 Maintenance 19 Troubleshooting 20 Spare Parts 22 Drawings 23 Model Model Model Model Model Model Page 2 of 43

3 ontents Drawings - ontroller oards 29 Display oards for Models 520, 530, Display oard for Models 540, 570, Relay oard for Models 520, 530, Relay oard for Models 540, 570, Drawings - Heat Exchangers 33 Metallic Heat Exchangers (Temperature Sensing) ll Models 33 Metallic Heat Exchangers (Non-Temperature Sensing) ll Models 35 Glass Kynar (Temperature Sensing) ll Models 37 Glass Kynar (Non-Temperature Sensing) ll Models 39 Limited Warranty 41 Page 3 of 43

4 Receiving and Storage The Universal nalyzers 500 Series Thermoelectric Gas oolers are completely pre-assembled. No assembly is necessary when received on-site. arefully inspect the product and included accessories immediately on arrival by removing them from the packing and checking for missing articles against the packing list. heck the items for any damage which may have occurred during transit and immediately inform the shipping insurance company of any damage found. Refer to the Specifications section (page 6) for information regarding storage requirements. Page 4 of 43

5 Definition of Symbols WRNING - EPLOSION HZRD - DO NOT DISONNET EQUIPMENT UNLESS POWER HS EEN SWITHED OFF OR THE RE IS KNOWN TO E NON-HZRDOUS. WRNING - EPLOSION HZRD - SUSTITUTION OF OMPONENTS MY IMPIR SUITILITY FOR HZRDOUS RE INSTLLTION. THE SUPPLY POWER IRUIT MUST INLUDE N OVERPROTETION DEVIE WITH MIMUM RTING OF 20. DISONNET SWITH MUST E LOTED IN LOSE PROIMITY TO THE PROE. IF THE EQUIPMENT IS USED IN MNNER NOT SPEIFIED Y THE MNUFTURER, THE PROTETION PROVIDED Y THE EQUIPMENT MY E IMPIRED PER LUSE 5.4.4(i) IN STNDRD EN UTION, RISK OF DNGER SYMOL INDITES INJURY MY OUR IF MNUFTURER S INSTRUTIONS RE NOT DHERED TO. PLESE RED MNUL REFULLY WHEN SYMOL IS DISPLYED UTION, HOT SURFE SYMOL INDITES EPOSED SURFE TEMPERTURE N USE URNS OR PERSONL INJURY. RE SHOULD E TKEN WHEN ONTT IS REQUIRED. UTION, RISK OF ELETRIL SHOK SYMOL INDITES ELETRIL SHOK MY OUR. UTION SHOULD E TKEN EFORE DISONNETING OR ONTTING NY ELETRIL ONNETIONS. PROTETIVE ONDUTOR TERMINL SYMOL INDITES THE TERMINL LOTION FOR THE PROTETIVE ONDUTOR. FILURE TO ONNET TO THE PROTETIVE ONDUTOR TERMINL MY RESULT IN SHOK HZRD. Page 5 of 43

6 Specifications OPERTING SPEIFITIONS Sample Flow Rate Model to 2 1/2 l/m total (at STP) Model to 5 l/m total (at STP) Model to 4 l/m total (at STP) Model to 5 l/m total (at STP) Model to 4 l/m total (at STP) Model to 4 l/m total (at STP) Maximum Inlet Temperature Stainless Steel Heat Exchanger 700 F (351 ) Kynar/Glass Heat Exchanger 280 F (138 ) Maximum Inlet Gas Dew Point 180 F (82 )* Maximum Inlet Water oncentration 50%* Minimum mbient Temperature 34 F (1 ) Maximum mbient Temperature 105 F (41 )* Maximum ooling Power Model TUs per hour (60 kj/hr) Model TUs per hour (60 kj/hr) Model TUs per hour (120 kj/hr) Model TUs per hour (120 kj/hr) Model TUs per hour (120 kj/hr) Model TUs per hour (120 kj/hr) Outlet Sample Dew Point 41 F (5 ) Gas Sample Inlet Fitting 3/8 tubing fitting Gas Sample Outlet Fitting 1/4 tubing fitting ottom Water Drain Fitting 3/8 tubing fitting Maximum Input Power Model watts Model watts Model watts Model watts Model watts Model watts Voltage ll models / V, 50/60 Hz Electrical lassification General Purpose, NEM 1 Dimensions ** Model H x 9 W x 9 D Model H x 11 W x 9 D Model H x 11 W x 10 D Model H x 9 W x 9 D Page 6 of 43

7 Specifications Weight Model 570 Model 574 Model 520 Model 530 Model 540 Model 560 Model 570 Model H x 11 W x 10 D 11 H x 11 W x 11 D 19 lbs (8.5 kg) 21 lbs (9.5 kg) 21 lbs (9.5 kg) 21 lbs (9.5 kg) 25 lbs (11.5 kg) 25 lbs (11.5 kg) Soluble Gas Removal Rates NO 0% loss NO 2 <10% loss SO 2 < 2% loss O 0% loss O 2 < 2% loss Storage Requirements ool and dry location, -20 F < x < 120 F < 95 relative humidity, non-condensing * T REDUED FLOW RTE OVE 77 F (25 ) MIENT ** DIMENSIONS DO NOT INLUDE FITTINGS OR MOUNTING HRDWRE Page 7 of 43

8 Description and Principle of Operation PPLITION In order to accurately analyze combustion gases, moisture must be removed from the sample without removing gas components of interest. The Universal nalyzers Thermoelectric Gas ooler provides an ideal repeatable, and stable way to decrease the dew point of combustion gasses. This prevents water condensation in sample prefilters, sample pumps, and gas analyzers. Where water vapor is an interferrent, a stable and repeatable dew point becomes a part of the gas analyzer s performance specification. The 500 Series ooler provides this constant, resulting in an accurate analysis of the gas components of interest. The gas sample is first pulled through a sample probe, which usually contains a heated filter, and then through a heated sample line, which keeps the sample above its dew point. The 500 Series ooler then condenses water out of the sample, which lowers the dew point to 5 (41 F). The 500 Series Thermoelectric Gas oolers are for general purpose, light duty applications. Several models are available to meet various application conditions. Use the cooler selection chart below to best fit a model to the expected flow rates, water vapor concentrations, and ambient temperature conditions. If none of the models listed meet the needs of the application, contact your Universal nalyzers local sales representative for more options. GS OOLER SELETION HRT onditions Model mbient Water * * 574* 77 F (25 ) 90 F (32 ) 105 F (41 ) 12% 2.5 l/m 4.0 l/m 2.5 l/m 5.0 l/m 4.0 l/m 5.0 l/m 2.5 l/m 15% 2.0 l/m 4.0 l/m 2.0 l/m 4.0 l/m 4.0 l/m 4.0 l/m 2.0 l/m 30% 1.0 l/m 4.0 l/m 1.0 l/m 2.0 l/m 4.0 l/m 2.0 l/m 1.0 l/m 50% 0.6 l/m 4.0 l/m 0.6 l/m 1.0 l/m 4.0 l/m 1.0 l/m 0.6 l/m 12% 2.0 l/m 3.0 l/m 2.0 l/m 4.0 l/m 3.0 l/m 4.0 l/m 2.0 l/m 15% 1.8 l/m 3.0 l/m 1.8 l/m 3.5 l/m 3.0 l/m 3.5 l/m 1.8 l/m 30% 0.9 l/m 3.0 l/m 0.9 l/m 1.8 l/m 3.0 l/m 1.8 l/m 0.9 l/m 50% 0.5 l/m 3.0 l/m 0.5 l/m 0.9 l/m 3.0 l/m 0.9 l/m 0.5 l/m 12% 1.5 l/m 2.0 l/m 1.5 l/m 3.0 l/m 2.0 l/m 3.0 l/m 1.5 l/m 15% 1.2 l/m 2.0 l/m 1.2 l/m 2.5 l/m 2.0 l/m 2.5 l/m 1.2 l/m 30% 0.6 l/m 2.0 l/m 0.6 l/m 1.3 l/m 2.0 l/m 1.3 l/m 0.6 l/m 50% 0.3 l/m 2.0 l/m 0.3 l/m 0.7 l/m 2.0 l/m 0.7 l/m 0.3 l/m # of Gas Streams *THE DT PROVIDED IS FOR EH STREM Various combustion processes can produce high levels of corrosive elements. n array of materials is available for the 500 Series oolers, where gases come into contact with heat exchangers. 316SS is the most common option, and meets the needs of most general purpose applications. oatings of Silconert 2000, or Teflon may be added to the stainless steel heat exchanger to enhance chemical resistance. Heat exchangers may also be made of other materials for corrosion resistance, such as Glass/Kynar, Kynar /Kynar, and Hastelloy 276. ontact your local sales representative for information on which material is best suited for your application. New Jersey Thermocouple Types K and J are available for external monitoring of heat exchanger temperatures. Page 8 of 43

9 Description and Principle of Operation DESRIPTION The Universal nalyzers 500 Series Thermoelectric Gas oolers condition gas sample streams to remove water vapor. The gas sample is cooled thermoelectrically to a controlled temperature, and water vapor is condensed and removed. The key to success is being able to condense the water from a wet gas sample with a minimal loss of the water soluble gas fraction. The separation occurs in a classical impinger, which has a highly polished cylindrical surface, cooled to the desired dew point temperature. The gas sample is brought to the bottom of the cylinder through an insulated tube and allowed to rise through a narrow annular area at a relatively high Reynolds number to insure the entire sample is influenced by the cold surface. The condensate falls down the cold, polished surface in the form of a sheet (as opposed to droplets or the bubbling of the gas sample through the condensate) which minimizes the surface area in contact with the gas sample. The temperature of the cylindrical, condensation surface of the heat exchangers is maintained through intimate contact with aluminum heat transfer blocks. The blocks are cooled with thermoelectric elements, controlled to a temperature of 5. The temperature sensor is a type K thermocouple. The temperature controller is proportional with a band of 1. The fan cooled heat sink is constructed from anodized, pure aluminum fins which transfer heat to the surrounding air. The pure aluminum material is a far better conductor of heat than the aluminum alloys which are normally used for extruded heat sinks. The result is an assembly with superior heat exhausting capabilities under high ambient temperature conditions. The 500 Series oolers have a digital display for front panel indication of the operating temperature of each of the heat transfer blocks (switch selectable) in degrees entigrade. Two internal jumpers at the top of the control circuit board within the enclosure can be moved to change the indicated temperature to read out in degrees Fahrenheit. Three LED lamps to indicate the status of the cooler. The OOL lamp is a green LED which indicates when the operating temperature has fallen below the factory set temperature of 10. n Over-temperature relay is energized and closed to the cool position when the OOL lamp is on. The relay board within the enclosure has dual terminal strip relay contacts for alarm/shutdown purposes. The external gas sample pump may be interlocked with this relay to power off when temperatures become too high (fail safe). The DRY lamp is a green LED which indicates when there is no water in contact with the water carry-over sensor (provided separately or as a system option). If no moisture sensor is used, the lamp may be turned off by installing a jumper on the moisture sensor input terminals on the relay board. Without a moisture sensor installed, the DRY lamp is always lit and doe not indicate a condition. The moisture sensor relay, which is energized in the DRY condition, provides contacts to an annunciator panel and/or to turn off the sample pump in the wet condition. The T lamp is a red LED which indicates when there is a problem (open connection) in the temperature control thermocouple. The Over-temperature relay will also transfer to the high temperature condition if the red T lamp comes on. Universal nalyzers Sample hillers are designed to interface with a condensate carry over sensor. The standard sensor is provided with a filter (which is referred to as a SF ) or it can be ordered without a filter ( S ). This sensor is put in place as an early warning device to ensure that a clean, dry sample is presented to the analyzer(s), thereby minimizing future maintenance and/or costly repairs. ondensate sensor (S/SF) sold separately for 500/1000 series coolers. The sensor is designed to operate with any current model Universal nalyzers sample chiller. If the sensor needs to be used as a standalone device then a 100 Moisture Detection Module must be used in conjunction with the moisture sensor. The technology behind the SF is a capacitive proximity sensor this is advantageous because the condensate does not need to be conductive to trigger an alarm. The sensor has an M12 connector on the bottom and uses the same 1 meter cable (Universal nalyzers Part No ) to interface between the S/SF and all chillers and the 100 Moisture Detection Module. In addition, there is an LED indicator on the sensor itself that illuminates upon detection of condensation or particulate. Page 9 of 43

10 Description and Principle of Operation DESRIPTION LED INDITOR HRT LED olor Status ondition Relay Status OOL Green On Operating properly, temperature below 10 Over Temperature: Energized, towards OLD Off Temperature too high or unit is OFF Over Temperature: De-Energized, towards HOT DRY Green On S sensor connected and sample is dry ondensate Sensor: Energized, towards DRY Off Moisture detected or jumper installed ondensate Sensor: De-Energized, towards WET T Red On Temperature control T has D quality Over temperature: De-Energized, towards HOT Off Temperature control T has OK quality Does not affect relays gas sample pump may be provided as part of the sampling system. If the pump is placed ahead of the sample cooler, it should be provided with a heated head to avoid the condensation of water vapor. If the sample pump is placed after the sample cooler, drawing the sample through the cooler, the sample has been dried, and a standard, non-heated pump may be used. means to control the flow of the sample through the system should be available and visible to the operator. This may be accomplished through the use of pressure regulators with gauges, flowmeters, and/or flow control needle valves. ondensate removal from the heat exchanger(s) within the Sample ooler can be accomplished through one of the following methods: 1. continuously running peristaltic tubing pump. 2. Installing the heat exchanger as a bypass condenser, pulling excess sample through with an eductor. 3. Using float drain traps similar to a steam trap. This requires the sample within the cooler to be at a positive pressure. 4. Use of drain pots on level control with a removal pump. Page 10 of 43

11 Installation The 500 Series Thermoelectric Gas oolers are best suited for air conditioned environments. Each unit dissipates heat, and the surrounding area must be well ventilated to provide adequate cooling. The cooler should be located away from other heat sources. If located inside an enclosure, outside air should be ducted directly onto the heat sink, and thermostatically controlled fans and vents should be utilized. The interior of the enclosure should be insulated, and never mount the unit in direct sunlight to avoid solar heat loading. Route all sample gas lines directly to the 3/8 inlet tubing fittings located on the top of the cooler heat exchangers. When two gas streams are being cooled, the left side of the unit is considered to be channel 1, and the right side of the unit is channel 2. Sample outlet tubing fittings are reduced to 1/4. t the bottom of each heat exchanger, a 3/8 tubing fitting is provided for the condensate drain. The condensate fitting may be removed to expose a female 3/8 NPT connection. Equipment must be installed to remove the condensate such as a peristaltic pump, liquid drainer, or aspirated drainer. single head peristaltic pump is recommended. If an aspirator drain is utilized, the outlet tubing should have a small bore and be no longer than two feet to minimize back pressure. The drain must be run to an appropriate condensate disposal location. sample pump is normally required to pull the gas sample through the cooler. Water arry-over Filter (WOF) sensor is recommended for each sample path. The pump should be located between the cooler and the filter. clear glass bowl should be installed around the filter to allow checking of the condition of the filter while online. Each cooler consumes about 2 amps (at 115V) per every active heat exchanger. Use minimum wire size of 18 WG, stranded, tinned copper with a minimum rating of 300 Volts. Dual relays are provided for both the WET/ DRY and HOT/ OLD conditions. One set of relays are MOV protected and designed to interrupt power to the sample pump upon alarm. The temperature of the heat exchangers may be viewed on the display on the front of the unit. If a multiple channel unit has been provided, a selector switch on the right side of the display lets the user toggle the display from one block to the other. For these same cooler models, a second toggle switch on the left side of the display allows the user to view the settings for the relay and cooler temperatures. Jumpers inside the unit on the control panel allow setting the display for degrees elsius or degrees Fahrenheit. Sample pumps, SF sensors, drains, flow meters, regulators, and other optional equipment are available from Universal nalyzers. These may be purchased separately or installed on a complete 500 Series Sample onditioning System. ll installations shall be in accord with the manufacturer s instructions and the National Electric ode (NSI/NFP 70). Page 11 of 43

12 Electrical onnections Model 520 Page 12 of 43

13 Electrical onnections Model 530 Page 13 of 43

14 Electrical onnections Model 540 Page 14 of 43

15 Electrical onnections Model 560 Page 15 of 43

16 Electrical onnections Model 570 Page 16 of 43

17 Electrical onnections Model 574 Page 17 of 43

18 Start-Up pply power to the Universal nalyzers 500 Series Thermoelectric Gas ooler. The indicated temperature will start to drop immediately. It should be below the over-temperature set point in approximately four minutes and the OOL green LED lamp should light. When the temperature reaches the control point (set at 5 ), the rate at which the temperature drops will be reduced. It will stabilize between 4 and 5. Start the sample gas flow. Water should be observed to be removed from the bottom of the heat exchanger when steady state conditions are established. If condensate sensors are installed, the (DRY) light should remain on as dry gas is transported to the analyzer(s). Turn on the analyzer(s) and calibrate as required. Shutdown Stop sample gas flow to the Universal nalyzers 500 Series Thermoelectric Gas ooler by turning off the sample pump. llow the drain pump to run for several minutes to remove any remaining condensate from the heat exchangers. fter all condensate has been drained, turn off power to the cooler. Page 18 of 43

19 Maintenance efore performing any maintenance on the 500 Series Thermoelectric Gas ooler, ensure that all plant safety procedures are followed. The 500 Series ooler is designed for maintenance free operation, but if any is required, ensure power has been removed before maintenance is performed. For the best performance of the cooler, the following maintenance schedule is recommended: Maintenance ctivity Peristaltic pump Diaphragm sample pump lean heat exchanger Inspect heat sink fins Frequency Replace tubing every 3 months Replace diaphragm every 6 months nnually Monthly Page 19 of 43

20 Troubleshooting The following table should give an overview of possible errors and an instruction to check and to repair them (is not valid for the starting-up period of cooler). Error Possible reason heck/repair The presence of water Overloading of the refrigeration capacity of the cooler due to too much water vapor or too great a sample flow rate fault in the condensate removal equipment. The heat exchanger has become full of condensate n air leak in the condensate removal tubing The pressure of the compressed air driving the vortex tube has dropped below 60 psig at the inlet of the thermal valve Failure of the sample cooler No sample gas flow ondensate carry over The cooler is not cold enough and needs to be calibrated. See calibration procedure below Heat exchanger plugged larm shutoff No power on cooler Inadequate drain apparatus Excessive flow rate High ambient temperature Defective cooler heck for an obstruction Remove heat exchanger from unit and disassemble Verify ool & Dry Indicators are illuminated Ensure cooler has power supplied Verify drain tubing is unobstructed and equipment is functioning satisfactory Reduce the flow rate Reduce the ambient temperature (Increase ventilation or relocate cooler) Verify air flow across the heat sink Hold hand in front of heat sink fins and ensure air movement Page 20 of 43

21 Troubleshooting High oxygen readings/ low pollutant readings ool light is not illuminated Power only on drain pump Leak mbient temperature too high Flow rate/ water content too high Failed Peltier element lown fuse (F1) Defective transformer (T1) Loose connection Verify all fittings are leak free Defective peristaltic pump tubing Replace tubing roken or leaking heat exchanger Remove heat exchanger and replace if broken or repair (replace O-Ring) if leaking Reduce the ambient temperature (Increase ventilation or relocate cooler) Lower the flow rate through the cooler and observe the results If condition corrects itself, consult the factory for further troubleshooting Measure resistance between the red & black Peltier leads. failed Peltier element will read high resistance or open. onsult wiring diagram for wire location details Replace fuse Replace power supply board Page 21 of 43

22 Spare Parts onsumable Parts Part P/N Fuse, ontrol oard - 2 mp Slow low Fuse, Power Supply oard - 6 mp Slow low asic Parts Part P/N Heat Exchanger/Impinger - 316SS S050 O-Ring for 316SS Heat Exchanger - Viton Heat Exchanger/Impinger - Glass/Kynar K050 O-Ring for Glass/Kynar Heat Exchanger - Viton (ottom) O-Ring for Glass/Kynar Heat Exchanger - Viton (Top) Glass Tube, Outer - Heat Exchanger Replacement Paste, Heat Sinking Ounce ontainer - ll Heat Exchangers ritical Parts Part P/N Peltier Element - 15VD, 8.5 mp, 40 mm Sq Insulation Kit - Heat Transfer lock Thermocouple, Type K - Peltier ontrol Fan, Heat Sink ooling Fan, Power Supply ooling ontroller ircuit oard - Single hannel (Models: 520, 530, 560) SN ontroller ircuit oard - Dual hannel (Models: 540, 570, 575) larm Relay ircuit oard - Single hannel (Models: 520, 530, 560) S larm Relay ircuit oard - Dual hannel (Models: 540, 570, 575) S Power Supply oard - 115V, 250 Watt, (15VD Output) Power Supply oard - 230V, 250 Watt, (15VD Output) Optional Parts Part P/N Motor, Peristaltic Pump - 120V, 6 RPM Motor, Peristaltic Pump - 230V, 12 RPM Head, Peristaltic Pump - for #15 Tubing Tube, Peristaltic Pump - 5 Feet Length # Sample Pump - 115V, Mini Dia-V luminum/teflon Single Head Sample Pump - 230V, Mini Dia-V luminum/teflon Single Head Sample Pump - 115V, Mini Dia-V luminum/teflon Dual Head Sample Pump - 230V, Mini Dia-V luminum/teflon Dual Head Sample Pump Rebuild Kit - Mini Dia-V (one per pump head required) Visible ondensate Proximity Sensor with 2 µm eramic Filter SF-0007 Filter Element - 2 µm eramic (for SF ssembly) owl, WOF Filter - Replacement With able Thermocouple Kit, Heat Exchanger - New Jersey Type K Page 22 of 43

23 Drawings Model 520 Page 23 of 43

24 Drawings Model 530 Page 24 of 43

25 Drawings Model 540 Page 25 of 43

26 Drawings Model 560 Page 26 of 43

27 Drawings Model 570 Page 27 of 43

28 Drawings Model 574 D /16 2 3/8 4 7/8 7 7/8 1/2 ONDUIT PORT 1/4 14 3/8 LEFT SIDE SEE SHEET 2 FOR WIRING SHEMTI /2 TYP TYP 9 1/2 TYP 3/8 TUE SMPLE INLET 4 TYP H1 H2 ONDENSTE DRINS 3/8NPT 4 TYP INTKE FN (INWRD FLOW) MOUNTING HOLES FOR 1/4 HRDWRE (SUPPLIED Y OTHERS) 4 TYP SMPLE INLET 3/8 TUE 4 TYP SMPLE OUTLET 1/4 TUE 4 TYP OOLING FN (UPWRD FLOW) 5 DUL INSULTED IMPINGERS 2 TYP HETSINK DUL HNNEL ONTROLLER & POWER SUPPLY ENLOSURE UNIVERSL NLYZERS IN onvair Drive arson ity,nevada US MODEL 574 SMPLE OOLER RRNGEMENT N/ 2 REV DTE DESRIPTION DWN PVD REVISIONS DTE 07/06/1998 PRT NO. FOR E. Musselman NOT ISSUED E 01/28/10 Revised For Modularity MW SLE SIZE SHEET NTS D 1 OF 2 DRWN Y DRWING NO. PVD Y T. arben 1 P0290 D D Page 28 of 43

29 Drawings - ontroller oards Display oard Models 520, 530, 560 D DISPLY TESTPOINT OMMON F OFFSET DISPLY TESTPOINT.... F F JUMPERS DISPLY DJUST P6 S2 ONTROL TEMP. SET LRM RELY SET 2 MP SLOW LOW FUSE PELTIER ONNETIONS D POWER INPUT GREEN RED YELLOW - - T6 R29 - R44 R37 R41 T THERMOOUPLE INPUT ONTROL TEMP. SET POINT LRM RELY SET POINT LIRTE SPN LIRTE ZERO FN FN ONTROL ORD SINGLE HNNEL SMPLE OOLERS UNIVERSL NLYZERS IN S. Sutro Terrace arson ity, Nevada US DRWN Y HRVEY MITHELL DRWING NO PVD Y P0023 DTE SLE SIZE SHEET 7/28/92 1 : 1 1 OF P1+ P2+ P3+ P4+ P2- P1- P3- P4- REV DTE DESRIPTION DWN PVD REVISIONS PRT NO. FOR J1 J2 R60 R64 D Page 29 of 43

30 R Drawings - ontroller oards Display oard Models 540, 570, 574 D 8 7 DISPLY TESTPOINT OMMON HNNEL 2 THERMOOUPLE INPUT ONTROL TEMP. SET POINT LRM RELY SET POINT LIRTE SPN LIRTE ZERO FM PPROVED 8 7 D POWER INPUT P1+ P2+ P3+ P4+ JUMPERS 2 MP SLOW LOW FUSE GREEN RED YELLOW R29 R41 THERMOOUPLE INPUT ONTROL TEMP. SET POINT LRM RELY SET POINT LIRTE SPN LIRTE ZERO P2- P1- P4- P T1 FN FN J1 J2 R60 R F OFFSET DISPLY TESTPOINT.... F F DISPLY DJUST P6 HNNEL 1 GREEN RED YELLOW R18 R8 R3 R12 PELTIER ONNETIONS R44 R /24/98 REVERSE R NUMERS HNNELS 1&2 EM T 07/27/93 HNNEL 1 & 2 ORIENTTION REVERSED HWM T REV DTE DESRIPTION REVISIONS DWN PVD ONTROL ORD DUL HNNEL SMPLE OOLERS NOTIE REVISION OF THIS DOUMENT MUST E UTHORIZED Y PPROPRITE PPROVL GENIES PRT NO. FOR INSTRUMENT NOT ISSUED UNIVERSL NLYZERS IN South Sutro Terrace arson ity, Nevada US DRWN Y HRVEY MITHELL DRWING NO PVD Y TED REN II P0024 DTE SLE SIZE SHEET 07/29/92 1 : 1 1 OF D Page 30 of 43

31 Drawings - ontroller oards Relay oard Models 520, 530, 560 D HET EHNGER - ONTROLLER ORD + +- FN OPTIONL MOISTURE SENSOR GROUND USER ONNETIONS TO MOISTURE SENSOR RELY. ENERGIZED WHEN SENSOR IS DRY (DRY LED ON). RTING: 1/10 HP 120V 5MPS 240V/ 32VD RESISTIVE. USER ONNETIONS TO T TEMPERTURE RELY. ENERGIZED WHEN ELOW SET TEMPERTURE (OOL LED ON). RTING: 1/10 HP 120V 5MPS 240V/ 32VD RESISTIVE. WET DRY WET DRY HOT OLD HOT OLD PROE OM } J N..1 RM1 N.O.1 N..2 * RM2 * N.O.2 * N..3 * RM3 * N.O.3 * N..4 RM4 N.O.4 RELY ORD LL RELY ONTTS UN-POWERED (DRY IRUIT) SHOWN IN DE-ENERGIZED (WET) POSITION SHOWN IN DE-ENERGIZED (HOT) POSITION HSSIS 50-60Hz 115V 8 POWER ORD GRN WHT LK N L 7 + POWER SUPPLY - * ONTTS PROTETED WITH 250 VOLT MOV'S FOR USE WITH 1/10 HP SMPLE PUMP 08/05/98 Update ddress in Title lock EM T REV DTE DESRIPTION REVISIONS NORML WIRING 520/530/1040/1050/1060 UNIVERSL NLYZERS IN South Sutro Terrace arson ity, Nevada US DWN PRT NO. FOR Not Issued Instrument DRWN Y HRVEY MITHELL DRWING NO PVD Y TED REN II P0003 DTE SLE SIZE SHEET 04/04/91 NTS 1 OF PVD D Page 31 of 43

32 R Drawings - ontroller oards Relay oard Models 540, 570, 574 HET EHNGER HSSIS 115V 50-60Hz POWER ORD - + FN ONTROLLER ORD - + GRN + WHT N LK L - POWER SUPPLY OPTIONL MOISTURE SENSOR USER ONNETIONS TO MOISTURE SENSOR RELY. ENERGIZED WHEN SENSOR IS DRY (DRY LED ON). RTING: 1/10 HP 120V 5MPS 240V/ 32VD RESISTIVE. { USER ONNETIONS TO T TEMPERTURE RELY. ENERGIZED WHEN ELOW { SET TEMPERTURE (OOL LED ON). RTING: 1/10 HP 120V 5MPS 240V/ 32VD RESISTIVE. OPTIONL MOISTURE SENSOR USER ONNETIONS TO MOISTURE SENSOR RELY. ENERGIZED WHEN SENSOR IS DRY (DRY LED ON). RTING: 1/10 HP 120V 5MPS 240V/ 32VD RESISTIVE. { USER ONNETIONS TO T TEMPERTURE RELY. ENERGIZED WHEN ELOW { SET TEMPERTURE (OOL LED ON). RTING: 1/10 HP 120V 5MPS 240V/ 32VD RESISTIVE. * ONTTS PROTETED WITH 250 VOLT MOV'S FOR USE WITH 1/10 HP SMPLE PUMP FM PPROVED NOTIE REVISION OF THIS DOUMENT MUST E UTHORIZED Y PPROPRITE PPROVL GENIES J8 UPPER RELY ORD FOR LEFT HND SIDE LL RELY ONTTS UN-POWERED (DRY IRUIT) WET DRY WET DRY HOT OLD HOT OLD N..1 RM1 N.O.1 N..2 * RM2 * N.O.2 * N..3 * RM3 * N.O.3 * N..4 RM4 N.O.4 J8 SHOWN IN DE-ENERGIZED (WET) POSITION HNNEL 2 SHOWN IN DE-ENERGIZED (HOT) POSITION LOWER RELY ORD FOR RIGHT HND SIDE LL RELY ONTTS UN-POWERED (DRY IRUIT) WET DRY WET DRY HOT OLD HOT OLD SHOWN IN DE-ENERGIZED (WET) POSITION N..1 RM1 N.O.1 N..2 * RM2 * N.O.2 * N..3 * RM3 * N.O.3 * N..4 RM4 N.O.4 HNNEL 1 SHOWN IN DE-ENERGIZED (HOT) POSITION 12/06/13 Moisture Sensor onnects To J8 MW D REV DTE DESRIPTION DWN PVD REVISIONS PRT NO. NORML WIRING 540/1080/1090 FOR 5200 onvair Drive arson ity, NV PH(775) F (775) DRWN Y HRVEY MITHELL EO# DRWING NO PVD Y TED REN 1910 P0022 DTE SLE SIZE SHEET 7/28/92 1 : 1 1 OF 1 Page 32 of 43

33 Drawings - Heat Exchangers Metallic Heat Exchangers (Temperature Sensing) Models 520, 530, 540, 560, 570, 574 D 8 TOP VIEW SMPLE GS INLET 1/4 NPT (FEMLE) /8 INSULTED SETION L (SEE TLE) HILLED SURFE THERMOOUPLE (TYPE K) (TYPE J) (TYPE T) 0.25 INSIDE DIMETER NNULR SPE.060 WIDE (GS TO E DRIED RISES IN THIS SPE) SIDE VIEW ONDENSTE DRIN 3/8 NPT (FEMLE) DRY GS OUTLET 1/8 NPT (FEMLE) 1). SEE SHEET 2 FOR SSEMLY INSTRUTIONS. PPRO LENGTH L S.S. HSTELLOY 276 LLOY 20 TITNIUM UNIVERSL EHNGER EHNGER EHNGER EHNGER NLYZERS P/N P/N P/N P/N SERIES 5200-SK K K TK SJ J J TJ ST T T TT SK K K TK SJ J J TJ ST T T TT /23/97 SHOW NEW DESIGN W/THERMOOUPLE RKET EM HWM REV DTE METLLI TEMPERTURE SENSING PRT NO. DRWN Y EV MUSSELMN DRWING NO PVD Y HRVEY MITHELL P0146 DTE SLE SIZE SHEET 12/11/95 1 : 1 1 OF 2 2 DESRIPTION REVISIONS HET EHNGER OUTLINE FOR SEE TLE SEE TLE UNIVERSL NLYZERS IN South Sutro Terrace arson ity, Nevada US 1 DWN PVD D Page 33 of 43

34 Drawings - Heat Exchangers Metallic Heat Exchangers (Temperature Sensing) Models 520, 530, 540, 560, 570, 574 D S.S SK SJ ST LLOY K J T50 5 HSTELLOY K J T50 5 TITNIUM 5200-TK TJ TT S.S SK SJ ST LLOY K J T10 10 HSTELLOY K J T10 10 TITNIUM 5200-TK TJ TT DRWN Y EV MUSSELMN DRWING NO PVD Y HRVEY MITHELL P0146 DTE SLE SIZE SHEET 12/11/95 1 : 1 2 OF South Sutro Terrace arson ity, Nevada US UNIVERSL NLYZERS IN. PRT NO. SEE TLE FOR SERIES METLLI TEMPERTURE SENSING HET EHNGER SSEMLY REVISIONS REV DTE DESRIPTION DWN PVD 01/23/97 SHOW NEW DESIGN W/THERMOOUPLE RKET EM HWM L MTERIL OMPLETE SSY OUTER TUE INNER TUE LENGTH DES. P/N SSY P/N SSY P/N TYPE K THERMOOUPLE SSEMLY P/N TYPE J THERMOOUPLE SSEMLY P/N TYPE T THERMOOUPLE SSEMLY P/N SPRE PRTS LIST OMPLETE SSEMLY OUTER TUE MTERIL IDENTIFIER INNER TUE MTERIL IDENTIFIER /2 PN HED SREW S S 2). LIGHTLY LURITE O-RING WITH SILIONE GRESE EFORE SSEMLY. L (SEE TLE) 1). O-RING IS FTORY INSTLLED IN METLLI OUTER TUE SSY /2 PN HED SREW METLLI INNER TUE SSEMLY NOTES: 1/16 TEFLON THERMOOUPLE SLEEVE S (TYPE K) (TYPE J) (TYPE T) P/N (SEE NOTES) METLLI OUTER TUE SSEMLY P/N VITON O-RING THERMOOUPLE SSY. S.S. OMPRESSION FITTING W/TEFLON FERRULES EPLODED METLLI HET EHNGER D Page 34 of 43

35 Drawings - Heat Exchangers Metallic Heat Exchangers (Non-Temperature Sensing) Models 520, 530, 540, 560, 570, 574 TOP VIEW SMPLE GS INLET 3/8 TUE SETION - PLUG 1/16 NPT INSULTED INNER TUE SSY OUTER TUE SSY VITON O-RING P/N L (SEE TLE) ONDENSTE DRIN 3/8NPT SMPLE GS OUTLET 1/4 TUE SETION - NNULR SPE.060 WIDE (GS TO E DRIED RISES IN THIS SPE) PPRO HET LENGTH EHNGER L P/N OUTER TUE MTERIL UNIVERSL NLYZERS SERIES S S.S. 400/ HSTELLOY / S05T TEFLON OTED 316 S.S. 400/ S S.S. 800/1000/1100/ HSTELLOY /1000/1100/ S01T TEFLON OTED 316 S.S. 800/1000/1100/ /08/13 Revise ssy Notes W GE REV DTE DESRIPTION REVISIONS DWN PVD HET EHNGER METLLI NON-TEMPERTURE SENSING OUTLINE PRT NO. SEE TLE FOR SEE TLE 5200 onvair Drive arson ity, NV PH(775) F (775) ). SEE SHEET 2 FOR SSEMLY INSTRUTIONS. EV MUSSELMN DRWING NO H. MITHELL 1531 P0147 DTE SLE SIZE SHEET 12/11/95 NONE 1 OF 2 DRWN Y EO PVD Y Page 35 of 43

36 Drawings - Heat Exchangers Metallic Heat Exchangers (Non-Temperature Sensing) Models 520, 530, 540, 560, 570, S DRWN Y EV MUSSELMN EO DRWING NO PVD Y H. MITHELL 1531 P0147 DTE SLE SIZE SHEET 12/11/95 NONE 2 OF S S01T onvair Drive arson ity, NV PH(775) F (775) PRT NO. SEE TLE FOR INSTRUMENT S05T HET EHNGER SSEMLY NON-TEMPERTURE SENSING METLLI S REV DTE DESRIPTION REVISIONS DWN PVD PPRO L LENGTH P/N INNER TUE SSY P/N OUTER TUE SSY P/N VITON O-RING #2-021 P/N PLUG 1/16NPT P/N 01/08/13 Revise ssy Notes W GE 3. NTI-SEIZE ON OUTER TUE THREDS. HET EHNGER SEPERLE SPRE PRTS LIST 2. LIGHTLY LURITE O-RING WITH SILIONE GRESE EFORE SSEMLY. 1. O-RING IS FTORY INSTLLED IN METLLI OUTER TUE. NOTES: OUTER TUE MTERIL IDENTIFIER INNER TUE SSEMLY L S VITON O-RING #2-021 SEE NOTES OUTER TUE SSEMLY METLLI Page 36 of 43

37 Drawings - Heat Exchangers Glass Kynar (Temperature Sensing) Models 520, 530, 540, 560, 570, 574 D 8 TOP VIEW SMPLE GS INLET 1/4 NPT (FEMLE) /8 HILLED SURFE THERMOOUPLE (TYPE J) (TYPE K) (TYPE T) DRY GS OUTLET 1/8 NPT (FEMLE) GLSS KYNR LENGTH HET EHNGER L SSEMLY P/N 5200-KK KJ KT KK KJ KT KK KJ KT NNULR SPE.060 WIDE (GS TO E DRIED RISES IN THIS SPE) INSULTED SETION INSIDE DIMETER SIDE VIEW L (SEE TLE) ONDENSTE DRIN 3/8 NPT (FEMLE) 1). SEE SHEET 2 FOR SSEMLY INSTRUTIONS. UNIVERSL NLYZERS SMPLE OOLER MODELS /02/01 dd 15 Heat Exchanger Data To Table EM JK REV DTE DESRIPTION DWN PVD REVISIONS Glass Kynar Temperature Sensing Heat Exchanger Outline PRT NO. SEE TLE FOR SEE TLE UNIVERSL NLYZERS IN. FG South Sutro Terrace arson ity, Nevada US DRWN Y E. Mussleman DRWING NO PVD Y H. Mitchell P0148 DTE SLE SIZE SHEET 12/11/95 1 : 1 1 OF D Page 37 of 43

38 Drawings - Heat Exchangers Glass Kynar (Temperature Sensing) Models 520, 530, 540, 560, 570, 574 D 8 THERMOOUPLE SSY. (TYPE K) (TYPE J) (TYPE T) 1/16 THERMOOUPLE TEFLON INSULTOR /2 PN HED SREW EPLODED GLSS KYNR HET EHNGER S.S. OMPRESSION FITTING W/TEFLON FERRULES P/N /2 PN HED SREW #2-120 VITON O-RING P/N (SEE NOTE 2) KYNR HED P/N (SEE NOTE 1) KYNR INSULTED SETION SSEMLY GLSS TUE #2-018 VITON O-RING P/N (SEE NOTE 2) KYNR DRIN FITTING P/N (SEE NOTE 1) GLSS KYNR HET EHNGER SSEMLY LENGTH L P/N KYNR INSULTED SETION SSEMLY P/N SPRE PRTS LIST GLSS TUE TYPE K TYPE J THERMOOUPLE THERMOOUPLE P/N P/N P/N KK KJ KT KK KJ KT KK KJ KT15 TYPE T THERMOOUPLE P/N NOTES: 1). O-RINGS RE FTORY INSTLLED IN KYNR HED ND KYNR DRIN FITTING. 2). LIGHTLY LURITE O-RINGS WITH SILIONE GRESE EFORE SSEMLY. 10/02/01 dd 15 Data To Parts List Table EM JK REV DTE DESRIPTION REVISIONS DWN PVD Glass Kynar Temperature Sensing Heat Exchanger Spare Parts List Exploded ssembly 7 OMPLETE GLSS KYNR HET EHNGER SSEMLY 7/8 WRENH FLTS PRT NO. FOR SMPLE OOLERS SEE TLE UNIVERSL NLYZERS IN South Sutro Terrace arson ity, Nevada US DRWN Y E. Musselman DRWING NO PVD Y H. Mitchell P0148 DTE SLE SIZE SHEET 12/11/95 1 : 1 2 OF D Page 38 of 43

39 Drawings - Heat Exchangers Glass Kynar (Non-Temperature Sensing) Models 520, 530, 540, 560, 570, 574 D 8 TOP VIEW SMPLE GS INLET 3/8 TUE PLUG 1/16 NPT 6 LENGTH L HILLED SURFE DRY GS OUTLET 1/4 TUE GLSS KYNR HET EHNGER SSEMLY P/N 5200-K K K015 UNIVERSL NLYZERS SMPLE OOLER MODELS FG NNULR SPE.060 WIDE (GS TO E DRIED RISES IN THIS SPE) INSULTED SETION INSIDE DIMETER SIDE VIEW L (SEE TLE) ONDENSTE DRIN 3/8NPT 1). SEE SHEET 2 FOR SSEMLY INSTRUTIONS. QTY OF EHNGERS PER SMPLE OOLER /19/04 Revision Per Sheet 2 RPH T REV HET EHNGER GLSS / KYNR NON-TEMPERTURE SENSING OUTLINE DRWN Y EV MUSSELMN DRWING NO PVD Y H. MITHELL P0149 DTE SLE SIZE SHEET 12/11/95 1 : 1 1 OF 2 2 DTE PRT NO. DESRIPTION REVISIONS FOR INSTRUMENT SEE TLE UNIVERSL NLYZERS IN South Sutro Terrace arson ity, Nevada US 1 DWN PVD D Page 39 of 43

40 Drawings - Heat Exchangers Glass Kynar (Non-Temperature Sensing) Models 520, 530, 540, 560, 570, 574 D 8 PLUG 1/6NPT EPLODED GLSS KYNR HET EHNGER #2-120 VITON O-RING (SEE NOTE 2) KYNR HED (SEE NOTE 1) GLSS TUE KYNR INSULTED SETION SSEMLY #2-018 VITON O-RING (SEE NOTE 2) KYNR DRIN FITTING (SEE NOTE 1) KYNR DRIN FITTING 15 VERSION GLSS KYNR HET EHNGER SSEMLY LENGTH L P/N K050 KYNR INSULTED SETION SSY P/N GLSS TUE P/N SPRE PRTS LIST KYNR DRIN FITTING P/N #2-120 VITON O-RING P/N #2-018 VITON O-RING P/N K KYNR HED P/N /16 NPT PLUG P/N K /8 WRENH FLTS NOTES: OMPLETE GLSS KYNR HET EHNGER SSEMLY 1). O-RINGS RE FTORY INSTLLED IN KYNR HED ND KYNR DRIN FITTINGS 2). LIGHTLY LURITE O-RINGS WITH SILIONE GRESE EFORE SSEMLY. 01/19/04 dded Kynar Drain P/N for 15 Length RPH T REV DTE HET EHNGER GLSS / KYNR NON-TEMPERTURE SENSING SPRE PRT INSTLLTION PRT NO. DESRIPTION REVISIONS DWN PVD FOR INSTRUMENT SEE TLE UNIVERSL NLYZERS IN DRWN Y EV MUSSELMN DRWING NO PVD Y H. MITHELL P0149 DTE SLE SIZE SHEET 12/11/95 1 : 1 2 OF South Sutro Terrace arson ity, Nevada US 1 D Page 40 of 43

41 Limited Warranty I. Limited Warranty 1. Limited Warranty. Universal nalyzers, Inc (UI) offers a limited warranty on each of its products against failure due to defects in material and workmanship for a period ending the earlier of (i) fifteen (15) months from the date of the invoice relating to the sale of the product and (ii) twelve (12) months from the date of installation of the product (collectively, the Initial Warranty ). During the Initial Warranty, UI offers a limited warranty against failure due to defects in material and workmanship on each part of a product repaired or replaced by an authorized service person for a period ending the later of (a) the remaining term of the Initial Warranty of the product and (b) ninety (90) days from the date of such repair or replacement. fter expiration of the Initial Warranty, UI offers a limited warranty against failure due to defects in material and workmanship on each part of a product repaired or replaced by an authorized service person for a period ending ninety (90) days from the date of such repair or replacement. UI further offers a limited warranty that the products and parts it sells will conform to UI s written specifications therefor. The foregoing limited warranties cover parts and labor only and UI does not warrant and will not reimburse the buyer of its products ( uyer ) for any costs relating to the access by service persons of UI to the product at issue. The foregoing limited warranties cover only the repair or replacement of defective parts and such determination will be in the sole discretion of UI. In its sole discretion, UI may make repairs or replacements under these limited warranties with either new or refurbished parts. To the extent uyer s product cannot be remedied under these limited warranties through repair or replacement of parts, uyer may return the product for a refund of the purchase price, less a reasonable reduction in such purchase price equal to the depreciation expense incurred by uyer relating to such product. The limited warranties of this Section I.1. are further subject to those warranty exclusions set forth below in Section I Limited Warranty Exclusions. Excluding the warranties provided for in Section I.1., UI provides all products to uyer as-is, without any other warranty of any kind. UI disclaims any and all express or implied warranties of merchantability, fitness for a particular purpose and non-infringement of the intellectual property of others. UI makes no warranty, express or implied, as to the design, sale, installation or use of its products. UI s warranties will not be enlarged by, nor will any obligation or liability of UI arise due to UI providing technical advice, facilities or service in connection with any product. There is no warranty by UI with respect to any product s: (i) uninterrupted or error-free operation; (ii) actual performance, other than the product s capability to meet UI s specifications therefor; (iii) removal or installation from a worksite or process; (iv) electronic components or associated accessories (including without limitation circuit boards and integrated circuits); (v) maintenance (including without limitation gasket and seal replacements, adjustments, minor repairs and other inspection requirements, preventative or otherwise); (vi) use under inappropriate conditions or not in accordance with operating instructions; or (vii) use in connection with the operation of a nuclear facility. There is no warranty for labor expenses associated with field repairs or the repair or replacement of defective parts in the engine or power unit of any product if such product has been in the possession of the owner or operator for greater than twelve (12) months. There is no warranty for products determined to be, in UI s sole discretion, damaged as a result of (a) misuse, neglect or accident; (b) improper application, installation, storage or use; (c) improper or inadequate maintenance or calibration; (d) operation outside of the published environmental specification; (e) improper site preparation or maintenance; (f) unauthorized repairs or replacements; (g) modifications negligently or otherwise improperly made or performed by persons other than UI; (h) uyer-supplied software or supplies; (i) use in conjunction with or interfacing with unapproved accessory equipment; (j) use of -style or dry powder fire suppression agents; or (k) leaked sample materials. To the extent a UI product is used in connection with the operation of a nuclear power facility, uyer agrees to indemnify and hold UI harmless from any and all actions, claims, suits, damages and expenses arising from such use. UI provides no warranty on the oral representations made by its personnel while they are attempting to assist uyer in the operation of a product. This Standard Limited Warranty does not apply to items consumed by the products during their ordinary use, including but not limited to fuses, batteries, paper, septa, fittings, screws, fuses, pyrolysis, dryer or scrubber tubes, sample boats, furnaces or UV lamps. 3. Non-UI Products. UI does not in any way warrant products it does not manufacture except to the extent the warranty of the manufacturer of the product at issue passes through or is otherwise assigned to UI. If a manufacturer warranty is so assigned to UI, UI will only be bound to comply with the length of time associated with such warranty. ll other terms of such warranty will be governed by this Standard Limited Warranty and UI s General Terms and onditions incorporated herein by reference. Page 41 of 43

42 Limited Warranty 4. Expenses on Non-Warranty Work. ll repairs or replacements by UI after the expiration of any applicable limited warranty period will be performed in accordance with UI s standard rate for parts and labor. Further, if upon UI s inspection and review, UI determines the condition of the products is not caused by a defect in UI s material and workmanship, but is the result of some other condition, including but not limited to damage caused by any of the events or conditions set forth in Section I.2., uyer shall be liable for all direct expenses incurred by UI to conduct the inspection and review of the product. 5. Exclusive Remedy. The foregoing limited warranty constitutes uyer s exclusive remedy with respect to products sold by UI and UI s liability shall be exclusively limited to the written limited warranty specified herein. No employee, representative or agent of UI is authorized to either expressly or impliedly modify, extend, alter or change any of the limited warranties expressed herein to uyer. 6. Procedure and osts. ll limited warranty claims must be made in writing promptly following discovery of any defect. uyer must hold defective products for inspection by UI. If requested by UI, uyer must send the product to UI for inspection. ny such returns by uyer will be at uyer s expense and uyer will remain liable for any loss of or damage to the product during such product s transportation to UI. No products will be sent to UI for inspection unless UI has authorized uyer to do so. 7. Terms and onditions. UI s General Terms and onditions are incorporated herein by reference and uyer accordingly agrees to be bound by the terms thereof. II. Limitations on UI Liability 1. In General. uyer agrees UI shall not be liable for any direct, indirect, incidental, punitive or consequential damages, including lost profits, lost savings or loss of use, whether uyer s claim is based in contract, tort, warranty, strict liability or otherwise, which uyer may suffer for any reason, including reasons attributable to UI. uyer agrees these limitations on UI s liability are reasonable and reflected in the amounts charged by UI for its products. 2. Force Majeure. This Standard Limited Warranty does not cover and UI shall not be liable for either direct or consequential damage caused, either directly or indirectly, as a result of: (i) any act of God, including but not limited to natural disaster, such as floods, earthquakes, or tornadoes; (ii) damages resulting from or under the conditions of strikes or riots, war, damages or improper operation due to intermittent power line voltage, frequency, electrical spikes or surges, unusual shock or electrical damage; or (iii) accident, fire or water damage, neglect, corrosive atmosphere or causes other than ordinary use. 3. Limitation on Warranty laims. Prior to any obligation of UI to perform any limited warranty service as set forth herein, uyer must have: (i) paid all invoices to UI in full, whether or not they are specifically related to the product at issue; and (ii) notified UI of the limited warranty claim within sixty (60) days from the date uyer knew or had reason to know of the defect Page 42 of 43

43 5200 onvair Drive arson ity, NV Phone: Fax: Page 43 of 43

Instruction Manual Series Vortex Gas Cooler

Instruction Manual Series Vortex Gas Cooler Instruction Manual 1100 Series Vortex Gas Cooler 5200 Convair Drive Carson City, NV 89706 Phone: 775-883-2500 Fax: 775-883-6388 www.universalanalyzers.com Contents Receiving and Storage 3 Definition of

More information

Instruction Manual Model 1095E

Instruction Manual Model 1095E Instruction Manual Model 1095E Acid Aerosol Freezer Chiller 5200 Convair Drive Carson City, NV 89706 Ph: 775.883.2500 Fax: 775.883.6388 www.universalanalyzers.com MAN.1095E.REVC.032017 TABLE OF CONTENTS

More information

Instruction Manual. 600 Series Mini Thermoelectric Gas Coolers (Units sold prior to )

Instruction Manual. 600 Series Mini Thermoelectric Gas Coolers (Units sold prior to ) Instruction Manual 600 Series Mini Thermoelectric Gas oolers (Units sold prior to 07-0-05) 500 onvair rive arson ity, NV 89706 Phone: 775-883-500 Fax: 775-883-6388 www.universalanalyzers.com ontents Receiving

More information

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 7428146 Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 1.0 SAFETY All compressed gases, including air, can be dangerous.

More information

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980

More information

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page

More information

CO2 Sensor User and Installation Guide

CO2 Sensor User and Installation Guide CO2 Sensor User and Installation Guide P/N: 110227 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7

More information

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual GG-VL-R REFRIGERANT VENT LINE SENSOR Installation and Operation Manual 2 GG-VL-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump

More information

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus MICRO GROW GREENHOUSE SYSTEMS, INC 42065 ZEVO DR., SUITE B-1, TEMECULA, CA 92590 PHONE (951)-296-3340 FAX (951)-296-3350 Growmate Growmate Plus INSTALLATION PROCEDURES GROWMASTER AND GROWMATE SERIES OF

More information

Series: MBC1-TC Mini Benchtop Temperature Controller

Series: MBC1-TC Mini Benchtop Temperature Controller User s Guide Series: MBC1-TC Mini Benchtop Temperature Controller Imagine Instruments LLC:: 4500 Williams Drive, Ste 212-318 :: Georgetown, TX 78633 :: p. 855.574.6243 e-mail: info@imagineinstruments.com

More information

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

Duct Mount. Installation Instructions

Duct Mount. Installation Instructions Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and

More information

Portable Induction Ranges

Portable Induction Ranges 9130, 9130-C 9131-1 9132-1 Portable Induction Ranges INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT INFORMATION READ BEFORE USE It is recommended that maintenance and repairs be conducted by authorized

More information

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3

More information

ion Genesis Pump Controller

ion Genesis Pump Controller High Water Alarm Document No.: IONG_OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

CD6102 / CD6102 OC / CD6102-2

CD6102 / CD6102 OC / CD6102-2 PreView Display CD6102 / CD6102 OC / CD6102-2 Operating Manual www.previewradar.com PATENTS Patented under one or more of the following U.S. Patents: 5345471, 5523760, 5457394, 5465094, 5512834, 5521600,

More information

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL 95 Methodist Hill Drive Rochester, NY 14623 Phone: US +1.585.321.5800 Fax: US +1.585.321.5219 www.spectracomcorp.com Part Number 8143-5000-0050

More information

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

Compact Equipment Warranty Policy

Compact Equipment Warranty Policy 006 07.15 Compact Equipment Warranty Policy 07/2015 Table of Contents Preface Page 1 Distributor s Warranty Responsibilities Page 1 Standard Warranties Page 2 Warranty Coverage Page 2 Warranty Limitations

More information

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through

More information

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

Portable Roller Oven (115 Volt) (230 Volt) Instruction Manual. Updated 8/11/2015 Ver. 3.0

Portable Roller Oven (115 Volt) (230 Volt) Instruction Manual. Updated 8/11/2015 Ver. 3.0 Portable Roller Oven 174-00 (115 Volt) 174-00-1 (230 Volt) Instruction Manual Updated 8/11/2015 Ver. 3.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300

More information

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4

More information

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...

More information

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all

More information

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual Installation and Operation Manual Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control Pump-Lead-Lag Warning This Heat-Timer control is strictly an operating control; it should

More information

OPERATION & INSTALLATION MANUAL

OPERATION & INSTALLATION MANUAL OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...

More information

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS DH07 shown INSTALLATION, OPERATION & MAINTENANCE MANUAL Manual P/N 92448 Rev. G 04/02/2009 Copyright 1998 Aladdin Temp-Rite Changes may be made to the

More information

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..

More information

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature

More information

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual GG-CO-EXP CARBON MONOXIDE SENSOR Installation and Operation Manual 2 GG-CO-EXP Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor Humidity Sensor Temperature/Humidity Sensor ES2-THB CSM ES2-THB_DS_E_3_2 Detect Humidity within an Accuracy of ±3% in a Compact Body. Set Provides Superior Humidity Control and Temperature/ Humidity Control.

More information

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

OPERATING MANUAL/ INSTALLATION

OPERATING MANUAL/ INSTALLATION NHW- 15 HOT WATER MACHINE OPERATING MANUAL/ INSTALLATION 120/240 V 1650/6600 W US 120/240 V 1350/5500 W CAN CONVERTIBLE 2 GA LLON DRIP TRAY INCLUDED ADVANCED TEMPERATURE CONTROL TVT TECHNOLOGY NEWCO ENTEPRISES

More information

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL. Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION...

More information

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating Modules INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL Andover Corporation 4 Commercial Drive Salem, New Hampshire 03079-2800 Tel: (603) 893-6888 US Toll Free: (888) 893-9992 Fax: (603) 893-6508 Email:

More information

MICRO GROW GREENHOUSE SYSTEMS, INC

MICRO GROW GREENHOUSE SYSTEMS, INC MICRO GROW GREENHOUSE SYSTEMS, INC 26111 YNEZ RD., SUITE C-4, TEMECULA, CA 92591 PHONE (951)-296-3340 FAX (951)-296-3350 Revision 1.3, 8/30/04 Ventmate Plus INSTALLATION PROCEDURES GROWMASTER, GROWMATE

More information

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web:   Rev. A Versa-Roll Roller Apparatus - Modular CLS-3857 OPERATIONS MANUAL 3800 North Mill Road Vineland, NJ 08360 USA Tel: 1-800-843-1794 Fax: 1-800-922-4361 Web: www.cglifesciences.com Rev. A Contents: General

More information

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL GASGUARD H2S EXP Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used

More information

R500E MANUAL (Software Version 2.0)

R500E MANUAL (Software Version 2.0) R500E MANUAL (Software Version 2.0) ONTENTS INTRODUTION 1 SPEIFIATIONS 2 INSTALLATION INSTRUTIONS 3 ELETRIAL WIRING 4 HEKLIST 5 ONTAT INFORMATION DRAWINGS D E F G GENERAL INTERONNETION DIAGRAM R500 RELAY

More information

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual EQUIPMENT Operation Manual Loctite SD15 Heat Controller Part Number 1667508 1 TABLE OF CONTENTS 1 Please Observe The Following... 3 1.1 Emphasized Sections... 3 1.2 For Your Safety... 3 1.3 Unpacking and

More information

VX SERIES Wireless Thermostat with Occupancy Sensor

VX SERIES Wireless Thermostat with Occupancy Sensor VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat

More information

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual Read and understand this material before operating or servicing these heating tapes. Failure to understand

More information

Power Pack Service Manual

Power Pack Service Manual Power Pack Service Manual MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information

Air Pump Up to 800 gallons

Air Pump Up to 800 gallons Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer

More information

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control Installation and Operation Manual Temperature and Pressure Monitoring for Heating and Cooling Applications Temperature Monitoring Control VALVE OPEN ALARM System= 128 o F Alarm At= 130 o F RESET /BACK

More information

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector IMPORTANT READ THIS FIRST....3 CAUTIONS... 3 AVOIDING NUISANCE ALARMS... 3 STANDARD FEATURES... 4 AVAILABLE OPTIONS... 4 PARTS DESCRIPTION... 5 FRONT PANEL

More information

HB CDA SERIES WITH TEMPERATURE SETBACK

HB CDA SERIES WITH TEMPERATURE SETBACK HB CDA SERIES WITH TEMPERATURE SETBACK 2013 NOVATEC, Inc. All Rights Reserved Document: HB CDA IM 7-24-2013 NOTES: Please record the following information, which is specific to this piece of equipment,

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual This owner s manual provides instructions on safe installation use, and troubleshooting assistance. Please read it carefully and save it for reference

More information

RK/ RK Oxygen Detector Operator s Manual

RK/ RK Oxygen Detector Operator s Manual 65-2502RK/65-2510RK Oxygen Detector Operator s Manual Part Number: 71-0074RK Revision: A Released: 3/1/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.

More information

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4

More information

RATIO:GUARD Model E-1S EC Monitor

RATIO:GUARD Model E-1S EC Monitor EC probe Probe tees Probe retention clips Temperature probe E-1S monitor box UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing

More information

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM) Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay 905-0005-01 (100/25 PPM) 905-0005-02 (200/35 PPM) 1. INTRODUCTION Your COSTAR VC carbon monoxide detecting ventilation

More information

AG Series Electric Heaters

AG Series Electric Heaters AG Series Electric Heaters Auxiliary Electric Heat Installation, Operation & Maintenance Instructions 97B0005N04 Table of Contents Overview 3 Vertical Upflow or Downflow Installation - Internal 3 Vertical

More information

Reacti-Therm I and III Heating/Stirring Modules

Reacti-Therm I and III Heating/Stirring Modules INSTRUCTIONS Reacti-Therm I and III Heating/Stirring Modules TS-18821 TS-18823 Number TS-18821 TS-18823 Description Reacti-Therm I Heating/Stirring Module (single block) Reacti-Therm III Heating/Stirring

More information

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia. Infrared Thermosensor CSM DS_E_3_2 Achieve Low-cost Measurements with an Infrared Thermosensor. The has an electromotive output as high as that of a thermocouple, thus connecting directly to the thermocouple

More information

GETZ MANUFACTURING PART # CYLINDER DRYER

GETZ MANUFACTURING PART # CYLINDER DRYER GETZ MANUFACTURING PART # 59339 CYLINDER DRYER 540 S. Main St., North Pekin, IL 61554 PH. (800) 553-3503 Fax (800) 473-6088 Website: www.getzmfg.com "YOUR FULL LINE EQUIPMENT MANUFACTURER" LIMITED WARRANTY

More information

MaxLite LED MICRO-T PANEL

MaxLite LED MICRO-T PANEL ` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all

More information

GAS MONITOR Model Model

GAS MONITOR Model Model Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00

More information

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 3227447 Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 GENERAL SAFETY INFORMATION 1. PRESSURIZED DEVICES: This equipment is a pressure containing device.

More information

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator TG-10 Wall Mount Installation and Operation Manual High Output Ozone Generator Ozone Solutions 451 Black Forest Road Hull, IA 51239 Phone: (712) 439-6889 Fax: (712) 439-6733 2 Table of Contents Safety

More information

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product

More information

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4

More information

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual GG-H2S HYDROGEN SULFIDE GAS SENSOR Installation and Operation Manual 2 GG-H2S Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

RK-02 Multi Point Detector Operator s Manual

RK-02 Multi Point Detector Operator s Manual 65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual

More information

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts

More information

PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE!

PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE! PLESE DO NOT RETURN THIS PRODUT TO THE STORE! OWNER S MNUL ENLOSED The owner s manual includes assembly and operating instructions, safety warnings, and the parts and hardware lists. If you have questions

More information

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR Model 91797 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure

More information

Remote Relay Module (RRM)

Remote Relay Module (RRM) Remote Relay Module (RRM) Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like

More information

EN Manual FINAL (Ambient) NEW 4/26/99 5:03 PM Page 1 AMBIENT

EN Manual FINAL (Ambient) NEW 4/26/99 5:03 PM Page 1 AMBIENT EN Manual FINL (mbient) NEW 4/26/99 5:03 PM Page 1 MIENT 1 INSTRUTIONS p.1 MODE D EMPLOI p.31 EDIENUNGSNLEITUNG p.61 ISTRUZIONI p.91 INSTRUIONES p.121 GERUIKSNWIJZING p.151 RUKSNVISNING p.181 p.201 EN

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION G Series (Model B) Convector Heater for Hazardous Locations Type G-Series Convection Heaters are designed for use in Class I, Div. I hazardous environments. Units without control options are suitable for

More information

Instruction Manual WARNING

Instruction Manual WARNING Controllers Instruction Manual WARNING THIS MANAUL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of

More information

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump Page 1 of 8 biohazard risk exists. Installer(s) and/or service personnel must use proper Personal Protective Equipment and follow handling procedures

More information

Power Pack Service Manual

Power Pack Service Manual Power Pack Service Manual MMPP4301-EP MMPP4301 MMPP4301-PKG MMPP4302 MMPP4302-PKG MMPP4305-PKG MMPP4301-WC MMPP4302-WC MMPP4305-PKG-WC www.micromatic.com 1 TABLE OF CONTENTS Equipment Specifications...

More information

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products: Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2

More information

Carbon Dioxide Sample-Draw Detector Operator s Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual 35-3001-05-03 Carbon Dioxide Sample-Draw Detector Operator s Manual Part Number: 71-0413 Revision: 0 Released: 8/4/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3 AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- 8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe

More information

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual GG-NO2 NITROGEN DIOXIDE GAS SENSOR Installation and Operation Manual 2 GG-NO2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

MaxLite LED VAPOR TIGHT LINEAR FIXTURES A cost effective LED Vapor Tight Fixture features a full length polycarbonate lens and a one-piece white glass reinforced polyester (GRP) body. Designed to meet or exceed seven to 10 foot-candles at 8

More information

Owner s Manual. PIR-1 IR Learner

Owner s Manual. PIR-1 IR Learner Owner s Manual PIR-1 IR Learner PIR-1 Owner s Manual 2010-2013 Universal Remote Control, Inc. The information in this owner s manual is copyright protected. No part of this manual may be copied or reproduced

More information

Protocol Station Remote Alarm

Protocol Station Remote Alarm ADI 5135-C Certified ISO 9001 Protocol Station Remote Alarm 529 5135-01-120 529 5135-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

FloorHeat Installation Manual

FloorHeat Installation Manual FloorHeat Installation Manual Transforming frosty floor surfaces into radiant warmth Transforming frosty floor surfaces into radiant warmth Contents Important Instructions!... 3 Safety Instructions:...

More information

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX 77041-4051 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN

More information

Power Pack Service Manual

Power Pack Service Manual Power Pack Service Manual MMPP4301-EP MMPP4301 MMPP4301-WC MMPP4301-PKG MMPP4301-PKG-WC MMPP4302 MMPP4302-WC MMPP4302-PKG MMPP4302-PKG-WC MMPP4303-PKG MMPP4303-PKG-WC MMPP4303-PKG-3 MMPP4305-PKG MMPP4305-PKG-WC

More information

Preamplifier Power Supply PPS-02 user's guide

Preamplifier Power Supply PPS-02 user's guide Preamplifier Power Supply PPS-02 user's guide 1 Table of contents 1. Warranty... 3 2. PPS-02 overview... 4 2.1. PPS-02 parameters... 4 2.2. Coding the symbol of the power supply...4 2.3. PPS-02 physical

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions PRH Series Plenum Heaters Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise

More information