COURSE SYLLABUS HVAC AND MECHANICAL CONSIDERATIONS FOR PART 3 BUILDINGS CORRESPONDENCE COURSE
|
|
- Rosanna Heath
- 5 years ago
- Views:
Transcription
1 COURSE SYLLABUS HVAC AND MECHANICAL CONSIDERATIONS FOR PART 3 BUILDINGS CORRESPONDENCE COURSE The course is organized into three bands. Band A covers HVACrelated building components and other types of building services such as wiring and piping and service spaces. Band B covers buildings that are required to incorporate smoke control systems and HVAC-related requirements for hazardous areas normally found in industrial occupancies. Band A addresses some important basic concepts in the ABC 2014 such as fire-resistance ratings and combustibility of materials. This information is necessary for SCOs to enforce requirements related to the installation of ducts and other building services in Part 3 buildings. The requirements for service rooms, vertical shafts and horizontal service spaces are also covered as these are the spaces in which building services are likely to be found. Band B addresses the many smoke control requirements that come into play in complex buildings such as high buildings, hospitals, jails and performing arts venues. It also discusses the HVAC-related requirements for buildings that are used for storage, use and handling of hazardous processes, substances and equipment. Band C provides a basic overview of the medical gas system. Objectives Identify the subsections of the ABC 2014 that are discussed in this course, define the term fire-resistance rating and describe how fire-resistance ratings are determined. Define the terms fire separation and fire compartment. Describe the requirements for continuity of fire separations. Describe the requirements for fire separations between occupancies. Describe the requirements for a special type of fire separation known as a firewall. v
2 Describe the requirements for fire separations in storage garages considered a separate building and in walkways separating buildings. Describe the fire separation and fire-resistance rating requirements of Articles to List the fire separation requirements for basements and storeys below ground. Describe the fire separation requirements for mezzanines, occupied roofs, roof-top enclosures, buildings with impeded egress zones and covered vehicular passageways. Identify buildings with large floor areas that may be subject to special fire separation requirements and describe waivers for fire-resistance ratings of assemblies in sprinklered buildings. Identify types of structures that would be considered as special and unusual structures and describe procedures for their approval. Describe requirements for the fire separation of suites. Describe requirements for the fire separation of public corridors. Describe requirements for fire separations in assembly occupancies. Describe requirements for fire separations in residential occupancies. Describe requirements for fire separations of exits and lobbies and describe the requirements for the integrity of exit facilities. Describe requirements for fire separations of elevator hoistways, dumbwaiters and elevator machine rooms. Identify the main categories of construction permitted by the ABC 2014, describe their basic characteristics and describe the test procedures used to evaluate combustibility of building materials. Describe the requirements for building services installed in a building of combustible construction, define the term flamespread rating and describe how to determine flame-spread ratings and smoke developed classifications of materials. Describe the requirements for combustible building services installed in a building of noncombustible construction. vi
3 Identify requirements for the protection of foamed plastic in buildings of both combustible construction and noncombustible construction. Define the terms closure and fire-protection rating, describe general requirements for closures and how fireprotection ratings are to be determined. Define the term fire damper and describe requirements for fire dampers. Describe general requirements for fire stopping of service penetrations through a fire separation. Describe requirements for fire stopping of electrical and plumbing service penetrations in fire separations. Describe fire alarm system requirements relating to the HVAC system. Describe requirements for the protection of electrical conductors. Describe requirements for building service controls located in a barrier-free path of travel. Identify areas in a building in which fire blocks are required. Describe requirements for materials used as fire blocks and describe the requirements for building service and other penetrations through fire blocks. Describe the fire separation and HVAC requirements for crawl spaces. Describe the requirements for separating service spaces and service rooms from the remainder of the building by fire separations and describe the requirements for electrical equipment vaults. Describe the requirements for fire separations and negative exhaust duct pressure in vertical service spaces. Describe the requirements for linen and refuse chutes. Describe the requirements for horizontal service spaces that penetrate a vertical fire separation and describe the dimensional requirements for access openings serving attic, roof and crawl spaces. Describe the requirements for air duct and plenum systems. vii
4 Describe basic air and smoke movement principles in high buildings and determine which buildings will be defined as high buildings. Describe the role of professional designers involved in the design of smoke control systems in high buildings and other buildings. Describe the requirements for smoke control systems and venting to aid firefighting in high buildings. Describe the requirements for elevators for use by firefighters and the central alarm and control facility. Identify when Articles to must be applied to mezzanines, floor areas and interconnected floor spaces and describe the HVAC-related fire-protection requirements of those articles. Describe options for providing protection from smoke in floor areas with a barrier-free path of travel above the first storey in a building that is not sprinklered. Describe smoke control requirements for Group A, Division 1 occupancies, including stages for theatrical performances. Describe smoke control requirements for Group B occupancies. Describe requirements for storage, handling and use of hazardous substances, equipment and processes. Describe the relationship between Subsection and the Alberta Fire Code 2014 and describe requirements for basements in buildings of industrial occupancy. Describe the requirements for repair and storage garages and vestibules serving them. Describe requirements for the design of hazardous areas. Describe the terms and defined words used regarding medical gas systems. Describe the principles used in designing a medical gas system. Describe types and locations of alarm systems, indicators, and alarm panels. Identify locations and physical requirements for pipeline systems; materials and methods allowed for constructing a viii
5 medical gas pipeline; and where shutoff valves are required in pipeline systems. Describe marking systems, locations, physical requirements and materials and methods allowed for construction of source systems, and identify proper routing of pipelines. Describe the reporting requirements regarding medical gas systems and tests to establish purity, gas specificity, flow, and operational requirements. Describe the differences between a typical health facility and those deemed to be small, non-hospital-based with a focus on particular equipment and testing differences. Ensure the systems continue to conform to the standard and describe inspection and testing requirements. Delivery Method Course is a self-paced, print-based correspondence course. You may work through this learning material at your own pace but must complete the course within six months. Advisor A course advisor will be available to answer your questions and discuss any issues you have regarding the course material. The course advisor will help you through any difficulties you experience with course material and is there to support you in being successful in accomplishing the course objectives. It is a good idea to touch base with your advisor regularly to make sure you are on track. You may contact your course advisor by or telephone. Structure This course material has three bands and 15 modules. Each module includes an introduction and a list of learning objectives to provide an overview of what you will be learning. Learning objectives are presented one at a time within the modules. There is a self-test at the end of each learning objective section. Complete all the self-tests to ensure you understand the course material and to help you prepare for the exam. ix
6 The course is designed to be completed in the order the material is presented. An understanding of concepts presented in one module may be required in subsequent modules. Required Reading Resources You must obtain the following publications to complete this course: Alberta Building Code 2014 Available from National Research Council Canada (NRC): Web: codes_centre/2014_alberta_building_code.html Phone: or Fax: Mail: Publication Sales M-23A National Research Council, 1200 Montreal Road Ottawa ON K1A 0R6 CSA Z Standard Recommended Reading Resources You will find reference to a number of standards developed by organizations such as the Underwriters Laboratories of Canada (CAN/ULC), National Fire Protection Association (NFPA) and international organizations equivalents. These materials are not required to successfully complete this course but provide additional information you may find valuable. The following publications are recommended to help you complete Band C. CSA Standard Z5359 Low-Pressure Hose Assemblies for Medical Gas Z9170 Medical Gas Terminal Units Z10524 Pressure Regulators, Gauges, and Flow Metering Devices for Medical Gas Systems x
7 Z10083 Medical Oxygen Concentrator Central Supply Systems: for Use with Non-flammable Medical Gas Piping Systems ISO/IEC General Requirements for the competence of testing and calibration laboratories These publications are available from the Canadian Standards Association. NFPA Standard 55 Compressed Gases and Cryogenic Fluids Code This publication is available from the National Fire Protection Association. Web: Phone: Mail: 1 Batterymarch Park, P.O. Box 9101 Quincy MA CGA Pamphlet G-8.1 Standard for Nitrous Oxide Systems at Consumer Sites This publication is available from the Compressed Gas Association Inc. Phone: Mail: 1725 Jefferson Davis Highway, Arlington VA Evaluation To receive credit for this course, you must earn a grade of at least 80 percent on the final exam. The exam is 3.5 hours long and has 70 multiple-choice questions. It is open book, which means you can refer to your course materials and related documents. You may complete the final exam online, under the supervision of a proctor. You and your proctor will be ed the passwords for the secure software download. The office must have your xi
8 completed Online Examination and Proctor Consent forms at least 48 hours in advance if you choose to write online. You may, instead, choose to write the exam in a paper-based format at the office, or at another location under the supervision of a proctor. To receive a hard copy of the exam, you and the proctor must complete a Proctor Consent. The office must have the form least one week before the date you wish to write the exam. The exam will be sent to your proctor. With the permission of the Canadian Standards Association, operating as CSA Group, material is reproduced from CSA Group standard, Z Medical gas pipeline systems Part 1: Pipelines for medical gases and vacuum, which is copyrighted by CSA Group, 178 Rexdale Blvd., Toronto, ON, Canada M9W 1R3. This Material is not the complete and official position of CSA Group on the referenced subject, which is represented solely by the standard in its entirety. While use of the material has been authorized, CSA Group is not responsible for the manner in which the data is presented, nor for any representations thereof. xii
COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE
COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE 100130 Description The first part of the course presents the requirements for fire alarm systems. It describes the buildings
More information2012 B.C. Building Code Compliance Review (Division B Part 3)
Planning and Building Department 2012 B.C. Building Code Compliance Review PROJECT NAME:.. CIVIC ADDRESS:...... PERMIT APPLICATION NO.:. DATE:... I,, have: 1. reviewed the design, plans and supporting
More informationPROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.
2012 B.C. Building Code Checklist (Division B Part 3) This checklist is provided as a reference only. The submission of this checklist with a Building Permit application should not be considered as a substitute
More informationBC Building Code Checklist Part 3 Planning and Development Department
BC Building Code Checklist Part 3 Planning and Development Department Project: Civic address: Permit No.: CRP: Certified Professional: Date: 1 Value of Construction: $ Developed Site Area: m2 2 BUILDING
More informationBOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015
Exam ID Examination Code Part BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015 BC3-7 Level III Exam 7 BCBC Part 3 (Part 3 Buildings Classification & Construction) BC3-8 Level III Exam 8 BCBC
More informationFIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES
FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES 1. The major objective is to provide an acceptable degree of life safety from fire in existing senior citizen lodges. This document
More informationBuilding & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!
Building & Fire Code Academy Building Better With Our Greatest Resource Education Welcome! Understanding the Sprinkler System Design Alternatives in the 2015 International Why inspect, test and maintain?
More informationWORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES
1 WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES TABLE 2.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF (1) ASSEMBLIES (Applies to each fire zone)
More informationSEMICONDUCTOR FABRICATION FACILITIES
CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply
More informationSEMICONDUCTOR FABRICATION FACILITIES
CHAPTER 18 SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply with this chapter and the International
More informationSEMICONDUCTOR FABRICATION FACILITIES
CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION 1801 GENERAL 1801.1 Scope. Semiconductor fabrication facilities and comparable research and development areas classified as Group H-5 shall comply
More informationSEMICONDUCTOR FABRICATION FACILITIES
CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES SECTION FC 1801 GENERAL 1801.1 Scope. This chapter shall govern the design, installation, operation and maintenance of semiconductor fabrication facilities
More informationWORKSHEET 3-1 THE MANITOBA OFFICE OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES
1 WORKSHEET 3-1 THE MANITOBA OFFICE OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES TABLE 3.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF (1) ASSEMBLIES (Applies each fire zone) Building
More informationThe course only requires the latest edition of the following documents: Building Code Compendium, Volume 1 and 2.
MODULE 1 INTRODUCTION AND INSTRUCTIONS ADMINISTRATIVE REQUIREMENTS flipchart. When asked by the Facilitator, the spokesperson will explain the group s answer, which forms the basis for class discussion.
More information2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014
2012 OBC Changes Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014 2012 OBC New Sentence 3.2.4.2(6) Buildings interconnected by walkways permitted in Articles
More informationPart 3 BUILDING CODE MYTHS & INTERPRETATIONS
Part 3 BUILDING CODE MYTHS & INTERPRETATIONS November 18, 2016 Frank Durante, RBO Building Inspector District of Mission Phone 604 820 3729 Wendy Morrison, AScT, BCQ GHL CONSULTANTS LTD Fire Science and
More informationLaboratories and Hazardous Materials. Company Overview
Laboratories and Hazardous Materials Don E. Contois, P.E. Sam Sinapi Company Overview R.W. Sullivan Engineering (RWS) was established in 1945 and currently has 95 employees. RWS is a full service engineering
More informationFirst Aspen Federal Regulation Set: K LSC 2000 Health Existing
First Aspen Federal Regulation Set: K 01.01 LSC 2000 Health Existing K 0000 Title CFR Type INITIAL COMMENTS Memo K 0011 If the building has a common wall with a nonconforming building, the common wall
More informationENERGY EFFICIENCY AFTER DECEMBER 31, 2016
MODULE 2 Energy Efficiency INTRODUCTION In this module the requirements for energy efficiency in buildings is examined with particular attention to the Supplementary Standard to the OBC, SB-10, Energy
More informationFor the Florida Building Commission And the Fire Code Advisory Council
Life-Safety Modifications Mechanical and Existing Building Compared to the 2012 Changes of the International Building Code and National Fire Protection Association- 101 For the Florida Building Commission
More informationAt the Montréal city council meeting of April 10, 1995, it was enacted that:
CITY OF MONTRÉAL BY-LAW 95-065 BY-LAW AMENDING THE BUILDING BY-LAW (B-1) At the Montréal city council meeting of April 10, 1995, it was enacted that: 1. Article 3 of the Building By-law (R.B.C.M., chapter
More information12/14/2013. Fire alarm and emergency power SPRINKLER HEAD
Fire alarm and emergency power SPRINKLER HEAD 1 Alert signal Alarm signal Fire detector Heat detector Smoke detector Smoke alarm 1. Detector locations 1. Fire detector locations (3.2.4.11) 2. Smoke detector
More informationCITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS
CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS Last Updated: April 28, 2008 FIRE REGULATIONS The purpose of fire regulations is to maintain an acceptable level of fire safety within CGS facilities.
More informationHCD DSA OSHPD 1 2 1/AC AC SS SS/CC
CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency
More informationShort Term Accommodations Fire Code Requirements
Short Term Accommodations Fire Code Requirements 1 Foreward The following is a comprehensive reference to Retrofit 9.3 of Division B of the Ontario Fire Code (OFC). Retrofit provisions were developed to
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter shall apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter shall apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationCOMPLIANCE ALTERNATIVES
CHAPTER 12 COMPLIANCE ALTERNATIVES SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter are intended to maintain or increase the current degree of public safety, health, and general welfare
More information***DRAFT - NOT FOR FILING***
ACTION: Original ***DRAFT - NOT FOR FILING*** DATE: 09/29/2017 1:14 PM 1301:7-7-27 Semiconductor fabrication facilities. (A) Section 2701 General (1) 2701.1 Scope. Semiconductor fabrication facilities
More informationNORTH CAROLINA. Downloaded (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided:
Housekeeping/Laundry/Maintenance NORTH CAROLINA Downloaded 01.15.11 (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided: (3) a soiled utility room with counter,
More informationOhio Department of Health NFPA 2012 Life Safety Code Tips Sheet
Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet This document is used for frequently cited Life Safety Code violations. This is not an all-inclusive list and is intended for reference only.
More informationBCBC 2012 CHANGES TO PART 3
BCBC 2012 CHANGES TO PART 3 Focus on changes that will have an practical effect. Basic concepts reviewed details to be confirmed. Material from Part 3 and related material from Part 9 Generally a harmonization
More informationCOMPLIANCE ALTERNATIVES
CHAPTER 12 COMPLIANCE ALTERNATIVES SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter are intended to maintain or increase the current degree of public safety, health, and general welfare
More informationFIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE
DEPARTMENT OF HEALTH AND HUMAN SERVICES CENTERS FOR MEDICARE & MEDICA SERVICE Form Approved OMB Exempt FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE
More informationBlack Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment
Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has
More informationSPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE 401.1 Detailed use and occupancy requirements. In addition to the occupancy and construction requirements in this code,
More informationAgency for Health Care Administration
Page 1 of 41 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0011 - LIFE SAFETY CODE STANDARD If the building has a common wall with a nonconforming building, the common
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter ((shall)) apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationPART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s
PART 2 Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s Occupancy Classifications Y A - Assembly Y B - Business Y E - Educational Y F - Factory/Industrial Y H - Hazardous
More information97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL
Page 2 of 16 EXPLANATORY MATERIAL In November 1996, the Fire Technical Council introduced a guideline entitled "Approved Fire Safety Guidelines for Apartment Buildings". The guideline was established under
More informationAgency for Health Care Administration
Page 1 of 51 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K0130 - MISCELLANEOUS Title MISCELLANEOUS OTHER LSC DEFICIENCY NOT ON 2786 FED - K9999 - FINAL OBSERVATIONS Title
More informationHealth Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE
Health Chapter 420-5-22 ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE CHAPTER 420-5-22 SUBMISSION OF PLANS AND SPECIFICATIONS FOR HEALTH CARE FACILITIES TABLE OF
More information2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content
Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015
More informationChapter Nursing Homes
Chapter 16.01 Nursing Homes Section 1. Licensing. No nursing, convalescent or old age home, as defined in Section 2 of this ordinance, shall be operated except under a license from the City Council of
More informationMajor Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing
Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing Ted Ross Labour & Advanced Education Gerard Donahoe Labour & Advanced Education Overview Where
More informationCHAPTER 7 ALTERATIONS LEVEL
CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration
More informationMajor Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014
Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014 Philip Rizcallah, P. Eng. NRC-IRC Canadian Codes Centre Presented by Stan Dueck CRBO Overview Where are the major
More informationAgency for Health Care Administration
Page 1 of 92 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General Requirements
More information2008 NYC Fire Code. New Laboratory Standards. Operational & Maintenance Provisions effective July 2008
2008 NYC Fire Code New Laboratory Standards Operational & Maintenance Provisions effective July 2008 Design & Certificate of Fitness Requirements Effective July 1, 2009 History The new Fire Code legislation
More informationBUILDING CODE COMMISSION
Ruling No. 03-30-928 Application No. 2003-34 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Sentence 3.1.8.12.(1)
More informationBuilding Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1
Building Codes & Standards for Healthcare Building Codes and Standards AHJs Codes Defend in Place Walls Sprinklers Fire Alarm Important Dates for Healthcare Facilities 7/5/16 NFPA Life Safety Code 101
More informationInterfacing Fire Alarm, Sprinkler and Elevator Systems
1 Interfacing Fire Alarm, Sprinkler and Elevator Systems Rodger Reiswig, SET Director, Industry Relations SimplexGrinnell November 17, 2010 Interfacing to Elevators 2 ASME A17.1 Safety Code for Elevators
More informationNFPA 101 Code Update from 2012 Edition to the 2015 Edition
NFPA 101 Code Update from 2012 Edition to the 2015 Edition Presented by: Gary Furdell AHCA Fire Protection Specialist 1 2 2012 Update to 2015 Chapter 18 New Health Care Occupancies 4 18.1.3.2 Atrium walls
More informationResidential-based Care Facility R-4 Guideline
Moreno Valley Fire Department Fire Prevention Bureau Residential-based Care Facility R-4 Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 7, 2017 Residential-based Care
More informationFIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES
BACKGROUND INFORMATION Alberta Fire Code 2014: FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES Alberta Fire Code (AFC) 2014, Division B, Section 5.6. requires a Fire Safety Plan for
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST TENANT IMPROVEMENTS Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;
More informationMAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS
FIRE CODE BULLETIN December 2004 97 FCB 018 (R1) Page 1 of 5 BACKGROUND: MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS Fire protection service companies are
More informationSummary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016
Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016 Ohio Administrative Code Rule Number OMC Section IMC origin Reason for proposed 4101:2-2-01 Air, Makeup 2015 Modified definition Air,
More informationAgency for Health Care Administration
Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title
More informationBUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007
BUILDING CODE OF THE CITY OF NEW YORK New York City Department of Buildings 4 June 2007 Fatma Amer, PE, Deputy Commissioner, Technical Affairs James Colgate, RA, Executive Architect John Lee, RA Keith
More informationCommon Building Code Misinterpretations
Common Building Code Misinterpretations Presented by: Ron Melucci, P.E. Technical Manager, FP Division Engineering Planning and Management, Inc. rbm@epm inc.com www.epm inc.com 508 875 2121 Engineering
More informationGASEOUS HYDROGEN SYSTEMS
CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationTHE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6
THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1 QUESTIONS How To Ask a Question: POLLING There will be occasional
More informationChanges to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates
Issued September 20, 2017 Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates Environment of Care (EC) Chapter Home Care (OME) Accreditation
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationSPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE 401.1 Detailed use and occupancy requirements. In addition to the occupancy and construction requirements in this code,
More informationAgency for Health Care Administration
Page 1 of 94 ST - K0000 - Initial Comments Title Initial Comments Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General
More informationRegistered Code Agency
obc - Registered Code Agency Home / Qualification & Registration / Registered Code Agency Registered Code Agency Examination Information Examination Program QuARTS - Online Examination program for Registered
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More information2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.
2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is
More informationNew DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE
DEPARTMENT OF HEALTH & HUMAN SERVICES CENTERS FOR MEDICARE & MEDICAID SERVICES FIRE SAFETY SURVEY REPORT - AMBULATORY SURGICAL CENTERS Medicare 1. (A) PROVIDER NUMBER Identifying information as shown in
More information4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.
Carsten Lunde, ASSE 6050 Instructor April 20, 2017 Carsten s Yearly Analysis, Inc. Any opinions expressed verbally by the speaker before you and all text in this presentation should be considered the speakers
More informationJanuary 1, 2014 Mandatory Effective Date
2013 Kentucky Building Code Highlights Winnie Blythe, Technical Advisor Dept. of Housing, Buildings, and Construction winnie.blythe@ky.gov www.dhbc.ky.gov 502-573-0373 January 1, 2014 Mandatory Effective
More informationFEO Initiation Devices Dean McLellan
FEO Initiation Devices Dean McLellan Enforcement Protocol 1. TSSAct 2. Ontario Regulation 209/01 3. Code Adoption Document (CAD) 4. Director s Orders 5. Applicable Code 1. Sub Codes (NBCC, CEC) A17/B44
More informationLABOUR PROGRAM. 14 TH ANNUAL OFNTSC TECHNICAL CONFERENCE AND TRADESHOW August 25, 2009
14 TH ANNUAL OFNTSC TECHNICAL CONFERENCE AND TRADESHOW August 25-27, 2009 National Building Code and National Fire Code Requirements for Schools and Arenas by Alexandra Chow, P.Eng. Fire Protection Engineering
More informationOAA Conference ,
OAA Conference 2013 OUR PROFILE OVERVIEW Amongst the world s leaders in professional services Listed on the Toronto Stock Exchange (GNV) $1.8 bn pro forma 2011 revenues 15,000 +300 35 EVERY CONTINENT EMPLOYEES
More informationFIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS > SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall specify where fire protection systems are required and shall apply to the design, installation,
More informationWORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS
1 WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS TABLE 4.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF ASSEMBLIES Construction
More informationNFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES
NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES Sharon S. Gilyeat, P.E., Principal Koffel Associates, Inc. www.koffel.com sgilyeat@koffel.com Expertly Engineering Safety From Fire
More informationFire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)
Fire resistance (A copy of this is available on www.routledge.com/books/details/ 9780415809696/).1 Fire resistance The overall aim of fire safety precautions is to ensure that: all corridor doors shall
More informationDate of Authorization May 26, 2005 BMEC Authorization BMEC Application # A
Building Materials Evaluation Commission 777 Bay Street, 2 nd Floor Toronto, Ontario, M5G2E5 Tel: 416: 585. 4234 / Fax: 416. 585. 7531 www.obc.mah.gov.on.ca Date of Authorization May 26, 2005 BMEC Authorization
More informationThe Cannabis Industry: Fire Department Requirements
The Cannabis Industry: Fire Department Requirements RVFD Standard 4.1 Rio Vista Fire Department 350 Main St. Rio Vista, CA. 94571 By: Jeff Armstrong, Fire Chief Updated December 2018 1 The purpose of this
More informationNFPA 45 NFPA 211 NFPA 1600
NFPA 45 NFPA 211 NFPA 1600 Prepared by: William E. Koffel, P.E., FSFPE Expertly Engineering Safety From Fire 1 Objectives Overview of the NFPA process Understand the scope and application of NFPA 45, NFPA
More informationTable of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME
Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME Section No. Subject Page No. 1 Authority and Purpose 10-1 2 Definitions
More informationCHAPTER 7 MECHANICAL VENTILATION AND SMOKE CONTROL SYSTEMS 7.1 AIR CONDITIONING & MECHANICAL VENTILATION SYSTEMS
CHAPTER 7 MECHANICAL VENTILATION AND SMOKE CONTROL SYSTEMS 7.1 AIR CONDITIONING & MECHANICAL VENTILATION SYSTEMS 7.1.1 General (a) Where air conditioning system is provided in lieu of mechanical ventilation
More informationHealth Care Engineers Fire & Life Safety Boot Camp
Health Care Engineers Fire & Life Safety Boot Camp MINNESOTA HEALTH CARE ENGINEERS ASSOCIATION FALL CONFERENCE SEPTEMBER 11, 2014 GARY SCHROEDER HEALTH CARE FIRE INSPECTOR MINNESOTA STATE FIRE MARSHAL
More informationDefend In Place 2012 IFC Overview of Institutional Occupancies
Defend In Place 2012 IFC Overview of Institutional Occupancies ICC Course No. ICC CEU s = 0.50 SCFA Course 8506-15-0 Nathan Ellis Cell: 864-812-5183 Nathan.Ellis@llr.sc.gov Institutional Occupancies Course
More informationDEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES
DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES (By authority conferred on the department of social services by section 9 of Act No. 380
More informationSCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY
SCHEDULE Essential s taken from Schedule 9 of the Building Regulations 2006 43 PART 1 BUILDING FIRE INTEGRITY 1 Building elements required to satisfy prescribed fire-resistance levels 2 Materials and assemblies
More information3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials
AMCA International Design Tips For Fire and Smoke Barriers William E. Koffel, P.E., FSFPE President, Koffel Associates, Inc. www.koffel.com Air System Engineering & Technology (ASET) Conference US San
More informationInterim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017
Interim Amendments to Ontario s 2012 Building Code Retirement Homes August 17, 2017 Notice This presentation is intended for general information purposes only. It is not intended as legal or technical
More information1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone
Medicine Hat Fire Service Construction Site Fire Safety Plan ABC Part 9 Buildings 1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone 403-529-8282 Email fireprevention@medicinehat.ca Small Buildings
More informationCOMMISSIONING OF LIFE SAFETY AND FIRE PROTECTION SYSTEMS: WHAT, WHERE AND HOW?
COMMISSIONING OF LIFE SAFETY AND FIRE PROTECTION SYSTEMS: WHAT, WHERE AND HOW? By: Ark Tsisserev, P.Eng. Senior Technical Manager Applied Engineering Solutions Ltd. CFAA Technical Seminar April 15, 2015
More informationGUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard
GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS High-Hazard This document shall apply to all Group H, High-Hazard occupancies. GENERAL Scope Reporting of emergencies, coordination with emergency response
More informationSPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE 401.1 Detailed use and occupancy requirements. In addition to the occupancy and construction requirements in this code,
More informationTHE MAURITIUS FIRE AND RESCUE SERVICE ACT. Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act
Government Notice 134 of 2018 THE MAURITIUS FIRE AND RESCUE SERVICE ACT Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act 1. These regulations may
More informationK SURVEY FOR DATE OF PLAN APPROVAL SURVEY UNDER
DEPARTMENT OF HEALTH AND HUMAN SERVICES CENTERS FOR MEDICARE & MEDICA SERVICES FIRE SAFETY SURVEY REPORT - HEALTH CARE Form Approved OMB No. 0938-0242 1. (A) PROVER NUMBER 1. (B) MEDICA I.D. NO. 1. HOSPITAL
More informationNotable Changes in the Mechanical Codes
Notable Changes in the Mechanical Codes July 2004 The following are some of the changes between the 1997 Uniform Mechanical Code and the 2003 International Mechanical Code(M) and the 2003 International
More informationCOMDTPUB P NVIC JUNE 1995
COMDTPUB P16700.4 NVIC 3-95 19 JUNE 1995 NAVIGATION AND VESSEL INSPECTION CIRCULAR NO. 3-95 Electronic Version for Distribution on the World Wide Web Subj: PERIODIC INSPECTION AND TESTING OF FIXED HALON
More information