MANUFACTURER OF POLLUTION CONTROL SYSTEMS

Size: px
Start display at page:

Download "MANUFACTURER OF POLLUTION CONTROL SYSTEMS"

Transcription

1 MANUFACTURER OF POLLUTION CONTROL SYSTEMS

2 MEGA SYSTEM INSTRUMENTATION MADE IN ITALY WE HAVE BEEN MANUFACTURING AND PRODUCING EQUIPMENTS FOR THE CONTROL AND MONITORING OF THE ATMOSPHERICAL POLLUTION SINCE 1981 We are the only company in our field to offer high quality and precision instruments at competitive prices and totally made in Italy. The hardware and software engineering, the realization of electronic cards, the assembling, the start up, the calibration and the relevant assistance are completely in-sourced and carried out with efficiency and accuracy by our highly qualified and trained personnel. Moreover we offer flexibility in the configuration of the systems we propose according to our customers needs. On October , Mega Systems achieved the Quality System certification according to the regulation UNI EN ISO 9001:2008. The achievement of this certification represent another confirmation of Mega System will to make quality one of our main characteristic of our production offer. This project has been undertaken with enthusiasm by Mega System with the belief that achieving this certification is not an arriving point, but the guarantee of our constant commitment finalized to guarantee a high level of quality for our products and offered services and to the pursuit of satisfaction for our customers. MEGA SYSTEM Srl Via Don Fracassi, Bareggio - (Milano) ITALY tel fax info@megasystemsrl.com C.F. e P.IVA graphic and photography Floriana Mantovani

3 LIFE LT - LIFE LT ATEX The constant flow personal samplers of the LIFE LT series is suitable for sampling according to Law Decree 81/2008. Is comply with the UNI EN 1232 standard and are available in ATEX version (group II 2 G Eex ib IIA T4). membrane pump (double head 2 m 3 /h) with high head operating range: 20 cc/min 6 l/min (with in line collector) manual adjustment of the flow by means of an external flow meter constant flow rate with automatic compensation of the load losses BY-PASS as standard which allows to carry out samplings at low flows without the aid of external accessories alarm signal out of range of 5% dimensions: 135 x 82 x 56 mm - weight: 650 g INDUSTRIAL HYGIENE LIFE XP - LIFE XP ATEX - LIFE XP Hi The constant flow personal samplers of the LIFE LT series is suitable for sampling according to Law Decree 81/2008. Is comply with the UNI EN 1232 standard and are available in ATEX version (group II 2 G Eex ib IIA T4). membrane pump (double head 2 m 3 /h) with high head operating range: 20 cc/min 6 l/min (with in line collector) manual adjustment of the flow by means of an external flow meter constant flow rate with automatic compensation of the load losses BY-PASS as standard which allows to carry out samplings at low flows without the aid of external accessories alarm signal out of range of 5% sampling programming by means of the keyboard and the display recording and display of temperature and sampled volume data storage - RS232 interface - USB port for data download to a flash drive (XP Hi version) dimensions: 135 x 82 x 56 mm - weight: 650 g LIFE XMF - LIFE XMF Hi The constant flow personal samplers of the LIFE LT series are extremely precise and reliable and are suitable for sampling according to Law Decree 81/2008. The samplers comply with the UNI EN 1232 standard. membrane pump (double head 2 m 3 /h) with high head operating range: 50 cc/min 5 l/min (with in line collector) digital flow setting by means of a built-in MASS FLOW (precision: 2%) recording and display of temperature and sampled volume constant flow rate with automatic compensation of the load losses BY-PASS as standard which allows to carry out samplings at low flows without the aid of external accessories alarm signal out of range of 5% data storage - RS232 interface - USB port for data download to a flash drive (XMF Hi version) dimensions: 135 x 82 x 56 mm - weight: 650 g MEGA MEGA SYSTEM SYSTEM 3 3

4 INDUSTRIAL HYGIENE LIFE 1 ONE LIFE ONE is an automatic sampler suitable to perform sampling operations complying with Law Decree 81/2008, and can also be used for gas and vapour collection. Compliant with standard UNI EN Practical and lightweight to transport, it may be powered by mains voltage, or used in environments where no power supply sources are available, thanks to the possibility to connect external optional batteries. membrane pump (2 m 3 /h) with high head operating range: 0,3 25 l/min constant flow rate with automatic compensation of the load losses digital flow setting and change through the keypad (even during sampling) recording and display of temperature and sampled volume alarm notification, storage and management dual power supply: mains 230 Vac - 50 Hz and 12 Vcc external batteries (not included) LIFE XP PLUS Designed in accordance with standard UNI EN This feature makes it suitable for the execution of sampling operations complying with the European directives on occupational health and safety of workers at work (Law Decree 81/2008). It s also particularly well suited for the execution of SEM asbestos sampling. membrane pump (2 m 3 /h) with high head operating range: 4 25 l/min manual adjustment of the flow by means of an external flow meter alarm signal out of range by 5 % INFO function for instrument identification data display up to 5 sampling data can be stored dual power supply: mains 230 Vac - 50 Hz and internal rechargeable batteries (integrated charger) LIFE XMF PLUS Designed in accordance with standard UNI EN This feature makes it suitable for the execution of sampling operations complying with the European directives on occupational health and safety of workers at work (Law Decree 81/2008). It s also particularly well suited for the execution of SEM asbestos sampling. membrane pump (2 m 3 /h) with high head operating range: 4 20 l/min digital flow measurement through MASS FLOW alarm signal out of range by 5 % INFO function for instrument identification data display up to 5 sampling data can be stored dual power supply: mains 230 Vac - 50 Hz and internal rechargeable batteries (integrated charger) 4 MEGA SYSTEM

5 ACCESSORIES INDUSTRIAL HYGIENE To complete the instrumentation, Mega System is able to offer the most varied and complete range of accessories for personal and environmental sampling: Filter holders Ø 25/37/47 mm Calibration nozzles Ø 25/37 mm Tapered nozzles Ø 25/37/47 mm (various entry holes for 1.25 m/s speed) and IOM preselector for BREATHABLE dusts Cylindrical nozzles Ø 25/37/47 mm for asbestos fibres Cyclones Dorr Oliver and GS3 Ø 25/37 mm for BREATHABLE dusts Single and multiple way flow regulators, complete with vial cover for the sampling of SOV Ball flow meters Glass scrubbers for ACID sampling Scrubber supports Telescopic tripod Collector support clamp Filter support boxes MEGA SYSTEM 5

6 ENVIRONMENT LIFETEK PMS In compliance with European standards UNI EN 12341:2014 CURRENTLY THE SYSTEM IS UNDERGOING CERTIFICATION BY TUV RHEINLAND IN COLOGNE LIFETEK PMS is a control unit for continual monitoring of atmospheric particles, using the gravimetric method, on a filtering membrane having a diameter of 47 mm. The sequential replacement system of the membrane, holding up to 16 filters, along with the electronic flow control, allow continual unmanned monitoring; it also allows to replace the exposed filters without having to stop the sampling under way. A thermo-regulated and differentiated conditioning and heating system allows to use the booth under extreme environmental conditions without affecting the electronic components and keeping the sampled filters at controlled temperature. The sequential system can also be equipped with sensors for the detection of meteorological parameters (wind speed and direction, humidity, etc), or interfaced with an existing meteorological unit, acquiring the relevant values rotary pump (6m 3 /h) operating range: 5 70 l/min. temperature sensors (ambient, filter, filter housing, gas meter), pressure sensors (barometric and vacuum) environmental sampling at constant flow rate: PTS, PM 10, PM 2,5 and PM 1, in compliance with European and American standards alarm notification, even through GSM module (OPTIONAL) low sound emission pump - Acoustic power: LW 70.6 db (A) SELECT DUO SELECT DUO is a compact system designed to perform sequential sampling of suspended particulate matter (SPM) and particulate matter (PM 10, PM 2,5 and PM 1 ) in compliance with the regulations in force. Easy to carry, can be housed in OUTDOOR environments, because it is made of materials able to ensure adequate protection against atmospheric agents. The system consists of 2 sampling lines that are selected sequentially through a solenoid valve. The "cyclical" function allows to perform 24-hour sampling synchronizing filter change at midnight, allowing to retrieve the sample filter at any time of the following day. The sampler can be equipped with an optional interface for connecting an external solenoid valve system (SELECT 8) to sample the suspended particulate matter (SPM) with an autonomy of 8 filters. rotary pump (6 m 3 /h) - operating range: 5 70 l/min temperature sensors (environment, counter), pressure sensors (barometric and vacuum) constant flow sampling of SPM, PM 10, PM 2.5 and PM 1 according to European and American standards GSM for alarm reporting (option) X1 - HORNET X1-HORNET is the High Volume sampler designed to be used in OUTDOOR environments for sampling: suspended particulate matter (SPM) on filter holder for 150 mm diameter membranes - IPA, dioxins and furans in the gas and particulate phase on filters Ø 102 mm and glass cartridge PUF/XAD2- Particulate matter (PM 10 /PM 2.5 ). Complies with ISO (particulate matter/gas), ISO (particulate matter), USEPA T09 and T013A (particulate matter/gas). The flow meter used is of Venturi type and is made in accordance with the standard UNI EN ISO Equipped with a 4 stage blower with a 60 m 3 /h or 90 m 3 /h brushless motor. flow electronic control control of the sampling flow rate at the current conditions and at the reference conditions keypad and large backlit LCD display for easy management of data sampling non volatile memory, RS 232 interface and USB Host GSM for alarm reporting (option) 6 MEGA SYSTEM

7 ACCESSORI ENVIRONMENT To complete the instrumentation, Mega System is able to offer a range of accessories for sampling PM 10, PM 2.5, PM 1, SPM, PAH, dioxins, furans and XAD2, in compliance with the European and American standards. The air conditioning system, the GSM system for managing alarms and the sequential systems SELECT 8 and SELECT 16 to be matched with external samplers, are also available. MEGA SYSTEM 7

8 EMISSIONS ISOCHECK LT ISOCHECK is a digital micro pressure gauge which, through the use of a L or S shaped PITOT tube with a K type thermocouple, allows to simply and immediately detect the differential pressure and temperature values for later calculation of the speed and flow rate in the duct. measured parameters: temperature and differential pressure calculations : speed, flow rate, standardised flow rate dimensions: 200 x 100 x 40 mm weight: 550 g ISOCHECK SRB The automatic ISOCHECK processor, through an L or S pitot tube with a thermo-couple, allows speed and flow measurements in compliance with UNI EN ISO The instrument is equipped with independent sensors for pressure measurement (DIFFERENTIAL, STATIC and BAROMETRIC) in order to meet the precision required by the normative. Connected to a LIFETEK XP-R it can perform automatic isokinetic samplings with continual update of the intake flow as the fume speed conditions vary. measured parameters: temperature, differential pressure, static pressure, barometric pressure calculations: speed, flow, normalized flow, isokinetic flow and nozzle flow data logger function power supply : Input 230 Vac - 50 Hz / and internal batteries (over 8 hours) dimensions: 200 x 100 x 40 mm weight: 550 g ISOCHECK TSB ISOCHECK TSB is the most full-featured and advanced instrument among the automatic processors for thermodynamic parameter measurement. It is equipped with independent sensors for the measurement of pressures (DIFFERENTIAL, STATIC and BAROMETRIC) to meet the precision requirements set out by the standard. It allows to perform speed and flow rate measurements in compliance with the standard UNI EN in force; if connected to a LIFETEK series sampler, it allows to perform automatic isokinetic emission sampling operations in compliance with standards UNI EN and ISO colour TOUCH display for display and programming measured parameters: duct temperature, differential pressure, static pressure, barometric pressure management of in-duct measurements, of isokinetic sampling and of branched line sampling customer personal data management duct/plants library dimensions: 330 x 290 x 155 mm - weight: 6 Kg 8 MEGA SYSTEM

9 MULTIPOINT Innovative and revolutionary automatic system for measuring the flow rate in a flue based on the simultaneous detection of the velocity values at each point of the measuring section in accordance with the specifications of the standard UNI EN ISO The system consists of the measurement and processing unit ISOCHECK MULTIPOINT and a particular sensor on which it is possible to mount up to 17 test probes (Darcy), the thermocouple and the static pressure socket. The probe is made of stainless steel and can reach the maximum length of 6 meters, connecting up to 3 support modules. The modular units are available in lengths of 1000, 1500 and 2000 mm. 10 colour TOUCH display for display and programming measured parameters: temperature, 17 differential pressures, static pressure, barometric pressure measurement integration and parameter logging at programmable intervals automatic sensor zeroing memory for data storage USB interface for storage expansion and/or data download EMISSIONS DARCY The DARCY tubes are made of stainless steel and comply with the standard EN ISO They come complete with thermocouple "K" for measuring temperature, have a diameter of 25 mm and are available in the following lengths: mm (other sizes available on request). They can be used as "stand alone" devices to calculate the velocity and the flow rate in a flue connecting them to a simple micromanometer (ISOCHECK LT) or with a sampling probe to make automatic isokinetic sampling (ISOCHECK series processors connected to the sampler of the series LIFETEK). PITOT The PITOT tubes (type AMCA) are made of stainless steel and comply with the standard UNI EN ISO They can be provided with or without thermocouple "K" for measuring temperature, have a diameter of 8 mm and are available in the following lengths: 600, 900, and 1200 mm (other sizes available on request). MEGA SYSTEM 9

10 EMISSIONS LIFETEK 33 XP-R The LIFETEK 33 XP-R sampler has been designed in accordance with standard UNI EN This feature makes it suitable for the execution of sampling operations complying with the European directives on occupational health and safety (Law Decree 81/2008). In fact it can be used for constant flow rate sampling in INDOOR/OUTDOOR environments and EMISSION isokinetic sampling. membrane pump (2 m 3 /h) with igh prevalence operating range: l/min electronic system for AUTOMATIC load loss compensation dedicated software in compliance with UNI EN ISO / UNI EN / ISO 9096 for: constant flow for ENVIRONMENTAL sampling SEMI-AUTOMATIC isokinetic sampling (manual entry of the duct parameters) AUTOMATIC isokinetic sampling ( automatic duct parameters detection) interface for connection with the ISOCHECK to sampler dual power supply: 230 Vac - 50 Hz and external 12 Vcc batteries (not included) LIFETEK 55 XP-R The LIFETEK 55 XP-R sampler has been designed in accordance with standard UNI EN This feature makes it suitable for the execution of sampling operations complying with the European directives on occupational health and safety (Law Decree 81/2008). In fact it can be used for constant flow rate sampling in INDOOR/OUTDOOR environments and EMISSION isokinetic sampling. double head membrane pump (4 m 3 /h) with high prevalence operating range: 1 50 l/min electronic system for AUTOMATIC load loss compensation dedicated software in compliance with UNI EN ISO / UNI EN / ISO 9096 for: CONSTANT flow environmental sampling SEMI-AUTOMATIC isokinetic sampling (manual entry of the duct parameters) AUTOMATIC isokinetic sampling ( automatic duct parameters detection) interface for connection with the ISOCHECK to sampler dual power supply: 230 Vac - 50 Hz and external 24 Vcc batteries (not included) LIFETEK 100 XP-R The LIFETEK 100 XP-R sampler has been designed in accordance with standard UNI EN This feature makes it suitable for the execution of sampling operations complying with the European directives on occupational health and safety (Law Decree 81/2008). In fact it can be used for constant flow rate sampling in INDOOR/OUTDOOR environments and EMISSION isokinetic sampling. rotary pump (6 m 3 /h) with high prevalence operating range: 5 70 l/min electronic system for AUTOMATIC load loss compensation dedicated software in compliance with UNI EN ISO / UNI EN / ISO 9096 for: CONSTANT flow environmental sampling SEMI-AUTOMATIC isokinetic sampling (manual entry of the duct parameters) AUTOMATIC isokinetic sampling ( automatic duct parameter detection) interface for connection with the ISOCHECK to sampler 230 Vac - 50 Hz supply 10 MEGA SYSTEM

11 X1 - APIS X1-APIS is the most advanced version of the automatic isokinetic samplers available on the market; it allows to measure velocity and flow rate in accordance with the UNI EN ISO and emission sampling in accordance with the UNI EN and ISO It is equipped with independent sensors for detecting differential, static and barometric pressure that meet the "accuracy" specifications required by the law. It is possible to install a 4 m 3 /h dual head diaphragm pump or alternatively, a 6 m 3 /h rotary pump. A feature that makes it unique is the ability to install the O 2 sensor (ELECTROCHEMICAL or paramagnetic) and the Carbon Dioxide (NDIR) sensor for the calculation of the density of the effluent in accordance with the regulations, recording its values during sampling with real-time adjustment of the isokinetic flow. The installation of a card for the acquisition of 4-20 ma / 1-10 V signals allows to record in the sampling report the data from other instruments (eg. analysers connected to the gas line of the X1-PROBE) or to use the acquired parameter for calculating the isokinetic flow in real-time. It is also possible to control the X1-CHILLER and the X1-PROBE adjusting all the temperature signals with data recording in the sampling report. EMISSIONS ARTIK XP ARTIK XP is a cooling system with automatic temperature control which can host various types of accessories (e.g. condensate collectors, glass condensers, etc.), allowing to perform sampling operations where the accessory cooling temperature needs to be constant for a very long time also in critical conditions (ambient temperature 35/40 C). The cooling temperature of the liquid inside the large tank is regulated and controlled by the built-in digital thermostat. The high degree of insulation of the tank walls ensures that temperature remains constant for prolonged periods of time. compressor refrigerating unit capacity: 2586 BTU/h (652 kcal/h) tank: 18 litres power supply: 230 Vac / 50 Hz dimensions: 370 x 320 x 560 mm loadless weight: 24 Kg X1 - CHILLER X1-CHILLER is a cooling system equipped with temperature control of the bath and of the recirculation pump of the liquid. It is suitable to cool the condenser of the micropollutants and the impingers for sampling acids and metals even simultaneously on two separate sampling lines. The high cooling capacity allows to make long-term sampling in critical situations (environmental temperature C), where it is essential to ensure a constant, controlled low temperature. The digital thermostat, on request, can be connected via serial cable to the X1-APIS isokinetic sampler in order to record the temperature of the bath and of the gases during sampling. The frame is made of metal frame and protected with ABS panels. compressor refrigerating unit capacity: 2514 BTU/h (634 kcal/h) tank: 7 litres power supply: 230 Vac / 50 Hz. dimensions: 380 x 280 x 550 mm Unladen weight: 20 kg MEGA SYSTEM 11

12 EMISSIONS STANDARD PROBE The STANDARD probes are made entirely of stainless steel. They integrate the measuring tube (Darcy with thermocouple) and the sampling tube with nozzles and filter holder that, united by the slider and fastener to the flue, allow to perform isokinetic sampling of dusts in emissions in stacks without or with little condensation. All components are designed and manufactured in accordance with the requirements of UNI EN ISO and UNI EN The assembled probe can be used in flues with inlet hole with the minimum diameter of 80 mm. The slider which is fixed to the stack allows tube handling in parallel to the execution of automatic isokinetic sampling. They are completely removable to facilitate transport and allow the use of the measuring tube independently of the sampling tube in small stacks. maximum temperature of usage 600 C available in different lengths: 500 mm mm mm mm mm SINGLE TUBE PROBE The single tube modular probe is made entirely of stainless steel and allows to perform isokinetic sampling of dusts in large stacks and with low temperatures. It consists of a sampling head connectable to a series of extensions that allow to mount a probe with a maximum length of 6 m. The sampling head integrates the measuring tube and the sampling tube on which you it is possible to mount the filter and the nozzle. The extensions can have different lengths and have a diameter of 60 mm. Within the extensions run the pneumatic connections that are made with silicone tubing. All components are designed and manufactured in accordance with the requirements of UNI EN ISO and UNI EN The assembled probe can be used in flues with inlet hole with minimum diameter of 80 mm. maximum temperature of usage 200 C probe max. length: 6000 mm extension length: 1000 mm 1500 mm 2000 mm THERMO HEATED PROBE The heated probes are suitable for sampling in emission where it is necessary to maintain a high temperature of the filter medium due to the presence of condensable substances in the gas to be sampled. They are made of stainless steel to ensure the necessary resistance to temperature and corrosion due to the aggressiveness of the gases in the flue. The temperature of the heated tube and the temperature in the external box are adjustable up to 200 C and are independently controlled by the THERMO thermostat which is placed under the external box. The particular resistances used to heat the tube and the external box are in armoured stainless steel to guarantee a perfect operation even in presence of high humidity in the stack. The sampling line to be inserted in the heated probes is available in glass, quartz, titanium and stainless steel. To perform isokinetic sampling it is possible to use the Darcy tube with thermocouple. maximum temperature of usage 350 C available in different lengths: 500 mm mm mm mm mm power supply: 230 Vac / 50 Hz 12 MEGA SYSTEM

13 THERMO DL HEATED PROBE The THERMO DL heated probes are suitable for sampling in emission where it is necessary to maintain a high temperature of the filter medium due to the presence of condensable substances in the gas to be sampled. They are made of stainless steel to ensure the necessary resistance to temperature and corrosion due to the aggressiveness of the gases in the flue. The temperature of the heated tube and the temperature in the external box are adjustable up to 200 C and are controlled independently by the THERMO DL thermostat which is placed under the external box. The THERMO DL thermostat is equipped with 2 inputs for auxiliary temperature sensors and HOST USB port for data download. The DATA LOGGER function allows to record temperature values at programmable intervals. The sampling line to be inserted in the heated probes is available in glass, quartz, titanium and stainless steel. maximum temperature of usage 350 C available in different lengths: 500 mm mm mm mm mm power supply: 230 Vac / 50 Hz. EMISSIONS X1 - PROBE HEATED PROBE X1-PROBE is a heated probe suitable for sampling micro-pollutants, metals and acids in emission that includes a sampling tube, a measuring tube and a SEPARATE TUBE for sampling GASES/ACIDS, protected by a filter in sintered paste. It can be used on any flue, even if horizontal, also thanks to the possibility of separating the external box from the heated tube and of mounting it rotated by 90. The temperature of the tube and the temperature of the external box are adjustable up to 200 C and are independently controlled via the thermostat under the box, equipped with 2 inputs for auxiliary temperature sensors and HOST USB port for data download. The DATA LOGGER function allows to record temperature values at programmable intervals. It is possible to prepare the probe for the connection via serial cable to the isokinetic sampler X1-APIS to adjust and record automatically from the instrument all temperature signals. The sampling line to be inserted in the heated probes is available in glass, quartz, titanium and stainless steel. maximum temperature of usage 350 C available in different lengths: 500 mm mm mm mm mm power supply: 230 Vac / 50 Hz. X1 - SWIRL The standard UNI EN ISO provides for the establishment of a new parameter required for the measurement of velocity and flow rate in gaseous flows: the SWIRL. X1-SWIRL is an accessory designed for use with measuring tubes and probes of any kind and allows to easily check the angle of the tangential flow compared to the axial direction. measuring range: +/- 180 resolution 0.1 zeroing: in any position MEGA SYSTEM 13

14 EMISSIONS ACCESSORIES To complete the instrumentation, Mega System is able to offer a range of accessories for sampling in emissions of dusts, metals, PAH, dioxins, furans, gases and acids. The accessories are available in stainless steel, titanium and glass. 14 MEGA SYSTEM

15 EMICHECK SERIES The portable analysers of the EMICHECK series are suitable to easily, quickly and accurately detect and monitor the emissions of fumes and gases generated by the different combustion processes. You can insert 3 to 8 sensors, choosing among: O 2 - CO - NO - NO 2 - SO 2 - C x H x CO 2 -CO 2 IR. The sensors used for gas detection are of electrochemical type, except for those used to detect the Total Hydrocarbons and the Carbon Dioxide, which are respectively a catalytic thermistor and an IR (infrared ray) sensor. The analyser is available in the EMICHECK Hi version, featuring a large colour, touch-screen LCD display and an archive with customer and system data. calculations complying with UNI permanent memory, built-in printer and Host USB port for data downloading logging of average and peak values referred to oxygen percentage and combustion data software for sensor calibration and check peltier cell cooling system with automatic release of the condensate dual power supply: 230 Vac / 50 Hz - internal batteries EMISSIONS LIFE XP GAS LIFE XP GAS is an instrument designed to execute low flow emission sampling, including: gas adsorption in the liquid phase by means of bubblers (acid) in compliance with Law Decree 25/08/2000 (Istisan Report 98/2) and gas adsorption in the solid phase by means of di adsorbing vials (SOV) in compliance with UNI EN It also complies with UNI EN The instrument is equipped with a MASS FLOW sensor allowing to automatically set, adjust and control the flow; a volume flow meter for the measurement of the sampled volume, as provided for by the regulations in force. max flow (double head 2 l 3 /h) operating range: l/min (with in line collector) dimensions: 240 x 260 x 285 mm weight: 5 Kg LIFE DUO - LIFE DUO DIL The LIFE DUO model combines in a single instrument two independent collection sections, for simultaneous sampling of emission gases and/or vapours, the LIFE DUO DIL model combines in a single instrument a gas sampling section and a dynamic dilution section, in compliance with standard UNI EN They are both in compliant with UNI EN Each sampling section of the instrument consists of a volume flow meter, a built-in volume flow meter and a keypad with LCD display. The dilution line includes the active carbon trap. membrane pump (8 l 3 /h) with high prevalence operating range: 20 l/min 4 l/min (with in line collector) built -in flow meter 0,2 4 l/min dual power supply: 230 Vac / 50 Hz - internal batteries dimensions. 320 x 350 x 315 mm weight: 11 kg MEGA SYSTEM 15

16 EMISSIONS ARTIK LT The ARTIK LT cooling system is a portable thermal container which can host appropriate accessories which are essential for condensate collection or for sampling, when they need to be cooled down. The temperature of the inserted accessories is lowered by filling the tank with cold water and using dry ice and/or frozen packs. This feature allows it to be used in environments where no power supply source is available, obviously for short-term sampling operations The ARTIK LT cooling system is supplied complete with a thermometer and an absorber/condenser support. dimensions: 340 x 310 x 380 mm loadless weight: 4.8 Kg GAS PROBE The probe with heated filter holder is suitable for emission sampling of acids and of Volatile Organic Compounds (Law Decree 25/08/2000 and UNI EN 13649). It consists of a removable sampling tube, of a heated 25 mm diameter filter holder and of a thermal regulator built into the handle allowing to set the heating temperature. The display allows to show the temperature of the heated filter holder. For acid sampling the probe can be set up for the connection of a self-limited heated teflon tube. The filter holder, besides, can also be equipped with an auxiliary connection for the dilution line in compliance with standard UNI EN in ducts with humidit. maximum usage temperature 200 C filter holder heating temperature: max 130 C tips available in different lengths: 350 mm 750 mm 1500 mm power supply: 230 Vac / 50 Hz UNICHIM PROBE The UNICHIM probe was designed to satisfy the need for sampling volatile organic compounds (VOC) according to the standard UNI EN in flues without or with little condensation. It consists of several longitudinal holes at equivalent distances that allow a "dispersion" sampling of the flue gases inside the flue. length: 1000 mm diameter: 8 mm 16 MEGA SYSTEM

17 SAMPLING SYSTEMS PERSONAL SAMPLING UNI EN 481:1994 The reference standard for personal sampling is UNI EN 481:1994. Workplace atmospheres. Size fraction definitions for measurement of airborn particles. The system allows to sample on a personal level any type of substance (solid, liquid or volatile) differentiating the type of sensor. LEGEND 1. Personal sampler 2. Filter holder 3. Conical nozzle for breathable dusts 4. IOM 5. Cylindrical nozzle for asbestos fibres 6. Cyclone for breathable dusts 7. Vial holder for volatile organic compounds (VOCS) 8. Accessories for instrument calibration MEGA SYSTEM 17

18 SAMPLING SYSTEMS FIXED STATION UNI EN 481:1994 The reference standard for indoor air sampling is UNI EN 481:1994. Workplace atmospheres. Size fraction definitions for measurement of airborn particles. The system allows to sample in an indoor confined area any type of substance (solid, liquid or volatile) differentiating the type of sensor. LEGEND 1. Life 1 One 2. Filter holder 3. Conical nozzle for breathable dusts 4. Cylindrical nozzle for asbestos fibres 5. Vial holder for volatile organic compounds (VOCS) 6. Scrubbers for acids 7. Telescopic stand 8. Support with gripper for stand 18 MEGA SYSTEM

19 SAMPLING SYSTEMS PARTICULATE MATTER UNI EN 12341:2014 The reference standard for sampling of particulate matter is UNI EN 12341:2014. "Ambient air - Reference gravimetric method for the determination of the mass concentration of suspended particulate matter PM 10 or PM 2.5." The system allows to sample particulate matter in an outdoor area. MEGA SYSTEM 19

20 SAMPLING SYSTEMS DUSTS UNI EN :2003 The reference standard for sampling of dusts in stacks is UNI EN :2003. Stationary source emissions. Determination of low range mass concentration of dust. Manual gravimetric method. The system allows to sample in flues of any size and type (vertical/horizontal) the total dusts in the presence of little condensation. LEGEND 1. Darcy 2. Conical nozzle 3. Filter holder 4. Isocheck SRB 5. Artick LT 6. Lifetek 55 XP-R 20 MEGA SYSTEM

21 SAMPLING SYSTEMS DUSTS UNI EN :2003 The reference standard for sampling of dusts in stacks is UNI EN :2003. Stationary source emissions. Determination of low range mass concentration of dust. Manual gravimetric method. The system allows to sample in flues of any size and type (vertical/ horizontal) the total dusts in the presence of a high amount of condensation. LEGEND 1. Darcy 2. Thermo DL 3. Filter holder 4. Isocheck TSB 5. Artik XP 6. Lifetek 55 XP-R MEGA SYSTEM 21

22 SAMPLING SYSTEMS METALS UNI EN 14385:2004 The reference standard for sampling of metals in stacks is UNI EN 14385:2004. Stationary source emissions. Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V. The system allows to sample heavy metals in flues of any size and type (vertical/horizontal). LEGEND 1. X-1 Probe 2. Absorber for Silica Gel 3. Impinger 4. X-1 Apis 22 MEGA SYSTEM

23 SAMPLING SYSTEMS HCI UNI EN 1911:2010 The reference standard for sampling of acids in stacks is UNI EN 1911:2010. Stationary source emissions. Determination of mass concentration of gaseous chlorides expressed as HCl. Standard reference method. Manual system for the determination of HCl in emission with a titanium probe (also available with glass probe). LEGEND 1. Thermo DL heated probe 2. Isocheck SRB 3. Filter holder 4. Absorber for Silica Gel 5. Lifetek 55 XP-R 6. Heated teflon tube 7. Impinger 8. Life 1 One MEGA SYSTEM 23

24 SAMPLING SYSTEMS DIOXINS, FURANS, PAH UNI EN :2006 The reference standard for sampling of micropollutants in stacks is UNI EN :2006. Stationary source emissions. Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs. Part 1: Sampling of PCDDs/PCDFs. The system allows to sample micro-pollutants (PAH, dioxins, furans) in flues of any size and type (vertical/horizontal). LEGEND 1. X1 - Probe 2. Absorber for Silica Gel 3. X1 Chiller 4. X1 Apis 24 MEGA SYSTEM

25 SAMPLING SYSTEMS SO x NO x HCl HF D.M. 25 AGO 2000 The reference standard for sampling sulphur and nitrogen oxides as well as inorganic compounds of chlorine and fluorine is the D.M. 25 August 2000 (Istisan report 98/2). IThe system allows to sample SO x, NO x, HCl and HF in conveyed gas flues. LEGEND 1. Gas probe 2. Artik LT 3. Absorber for Silica Gel 4. Life 1 One MEGA SYSTEM 25

26 SAMPLING SYSTEMS VOLATILE ORGANIC COMPOUNDS UNI EN 13649:2002 The reference standard for sampling sulphur and nitrogen oxides as well as inorganic compounds of chlorine and fluorine is the D.M. 25 August 2000 (Istisan report 98/2). The system allows to sample SO x, NO x, Hcl and HF in conveyed gas flues. LEGEND 1. Gas probe 2. Absorber for Silica Gel 3. Life Duo DIL 4. LIfe XP Gas 26 MEGA SYSTEM

27 SAMPLING SYSTEMS ANALYSIS OF COMBUSTION PROCESSES IThe system allows to detect using electrochemical cell and infrared sensors, the following parameters: O 2, CO, CO 2, NO, NO 2, SO 2, C x H x. LEGEND 1. Emicheck 2. Emicheck Hi MEGA SYSTEM 27

28 CUSTOMER CARE TECHNICAL ASSISTANCE Mega System srl offer a highly qualified, efficient and effective Technical Assistance to grant our customer satisfaction. The quality of a product and its performances are not the only important focuses to acquire new customers or loyalize them; as a matter of fact we strongly believe in an efficient and effective customer care service and after-sale assistance based on courtesy and clear explanations. CONSULTING We offer a technical consulting service for the selection of the suitable instrumentation according to the sampling to carry out and for the installation and/or the operation of the instruments produced and commercialized. TRAINING We train your technicians. QUOTATIONS We issue fast and free of charge quotations for the maintenance and the calibration of your instrumentation. MAINTENANCE We perform maintenance interventions, repair and calibration of instruments issuing the Test Report. INSTRUMENTS CALIBRATION To meet laboratories and companies requirements accredited by ACCREDIA or operating with an ISO 9000 qualified system, Mega System s.r.l. offer a calibration service for the instruments used to monitor the atmospheric pollution. Our laboratory is equipped with high precision and reliable instruments constantly maintained through periodic checks carried out by accredited Calibration Centers in Italy (SIT Centers) or by International Calibration Centers accredited by institutions of the EA-European co-operation for Accreditation (association which represents the European crediting institutions). This allows us to get a precise and reliable assessment and correction of the sampling carried out with these instrumentation. TEST REPORTS Our instrumentation is supplied with Test Reports with all data related to the carried out sampling. Moreover they contain the features of the instruments along with relevant procedures in order to infer the primary sampling according to the given results. INSTRUMENT CERTIFICATION We send your instrumentation to SIT Centers or International Calibration Centers for relevant certification. The service includes the preliminary and free check of the instrumentation and the calibration control with the Accredited Center. 28 MEGA SYSTEM

29 NOTE MEGA SYSTEM 29

30 CUSTOMER CARE NOTE 30 MEGA SYSTEM

31 MEGA SYSTEM 31

32 Via Don Fracassi Bareggio (Milano) Italy Tel Fax info@megasystemsrl.com Copyright Mega System Srl - all rights reserved - revisione 2.10.A4

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

Automatic Isokinetic Sampler ST5

Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Description The ST5 is the next generation isokinetic sampler, developed to be efficient, rugged, accurate and user friendly. The perfect

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser >10h Operation with Li-Ion Battery Pack Smart Autozero without Removal the Probe CO Dilution up to 10% Stores up to 250 Complete Analysis

More information

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines Gas Samplers Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines Gas Samplers Gas Flow Sampling of gases and air pollutants Gas flow diagram

More information

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN ) Page 1 of 7 All tests and sampling performed by the laboratory meet the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009. The Laboratory is qualified to update standards

More information

gas monitoring system

gas monitoring system www..com gas monitoring system Photon S is s most recent and most sophisticated apparatus. It was created based on portable gas analyser - Photon. As its sucessor it also uses gas sensors as the main measurement

More information

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

MicroTool.  Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS "Excellence in measurements" MicroTool Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS Visual/Audible Alarm Differential Manometer Differential Thermometer

More information

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test The

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the AMESA D Isokinetic Dioxin Sampling System Manufactured by: Environnement S.A. Deutschland Benzstraße 11 61352 Bad Homburg Germany has been assessed

More information

Your competent partner for measuring and services.

Your competent partner for measuring and services. Your competent partner for measuring and services. Intuitive, efficient, reliable everything for facility management: Welcome to the Smart World of Testo. 1 Too cold, too draughty, too humid? With the

More information

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 ALL-WEATHER REFRIGERATED SAMPLERS AS950 ALL-WEATHER REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 All-Weather Refrigerated

More information

Glenside Environmental Services Ltd

Glenside Environmental Services Ltd Unit 18 Great Island Industrial Park, Ballincollig, Co. Cork. Testing Laboratory Registration number: 322T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland']B:' Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Ceriificate No.: 0000028733 02 AMs designation: Manufacturer: SWAM 5a Dual Channel Monitor, SWAM 5a Dual Channel Hourly Mode

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION PRODUCTS INDEX EXPERT NANO 1LT 06 PLUS200 EXPERT THR 34 EXPERT NANO 3CF 08 PLUS300 EXPERT U THR 36 EXPERT NANO 4CK 10 PLUS1000 THR 38 EXPERT NANO 2ZN

More information

ACTIVITIES OF THE MEASURING GROUP

ACTIVITIES OF THE MEASURING GROUP ACTIVITIES OF THE MEASURING GROUP TABLE OF CONTENTS 1. Introduction 2. Flow measurements 3. Temperature measurements 3.1 Temperature profile of tunnel kiln loads 3.2 Other temperature measurements 4. Power

More information

AS950 REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,

More information

Complete Gas Analysis

Complete Gas Analysis Complete Gas Analysis A complete range of gas analysers, systems and accessories for emissions, air quality, research and process monitoring. The Signal Group, incorporating the gas analysis business of

More information

MicroRay IR-100 NEW. Inspection MicroRay IR-100

MicroRay IR-100 NEW. Inspection MicroRay IR-100 Inspection MicroRay IR-100 MicroRay IR-100 RIDGID MicroRay features fast and easy temperature measurements from a comfortable distance. The Infra Red technology allows non-contact, point and read functionality.

More information

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING SBI Single Burning Item - EN 13823 THE BENCHMARK IN FIRE TESTING FTT Single Burning Item (SBI) The importance of the SBI The European Construction Products Directive requires that all European Member states

More information

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314) Mass Sensors, Inc. 1350 Baur Blvd, St. Louis, MO 63132 (314) 997-5779 www.mass-sensors.com Innovations in chemical microsensors Profile Mass Sensors is a development stage high-tech company operating in

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate number: 0000028733_01 Certified AMS: Manufacturer: SWAM 5a Dual Channel Monitor for PMio and PM2,5 FAl lnstruments s.r.l.

More information

The New DUSTTRAK II and DRX Aerosol Monitors

The New DUSTTRAK II and DRX Aerosol Monitors The New DUSTTRAK II and DRX Aerosol Monitors HEALTH AND SAFETY Exposure Monitoring TRUST. SCIENCE. INNOVATION. Real-Time Dust Monitoring Takes A Giant Leap Forward. The Revolution in Real-Time Dust Monitoring

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK St laise House Vaughan Street radford West Yorkshire D1 2LL ontact: Mr A R Pullen Tel: +44 (0)1274 738668 Fax: +44 (0)1274 738758 E-Mail: technical@envirocare.org

More information

The New DUSTTRAK II and DRX Aerosol Monitors

The New DUSTTRAK II and DRX Aerosol Monitors The New DUSTTRAK II and DRX Aerosol Monitors HEALTH AND SAFETY Exposure Monitoring TRUST. SCIENCE. INNOVATION. Real-Time Dust Monitoring Takes A Giant Leap Forward. The Revolution in Real-Time Dust Monitoring

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

Datalogging as standard

Datalogging as standard Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable

More information

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems EUROPEAN COMMISSION JOINT RESEARCH CENTRE Institute for Reference Materials and Measurements (Geel) ANNEX I Technical specifications for: Supply of various Trace Explosive Detection Systems TABLE OF CONTENTS

More information

AS950 PORTABLE SAMPLERS

AS950 PORTABLE SAMPLERS AS950 PORTABLE SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Portable Sampler makes programming,

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

EAGLE 2X: C155KIT EAGLE 3X: C157KIT

EAGLE 2X: C155KIT EAGLE 3X: C157KIT EAGLE 2X: C155 C155 Analyzer Particle Filter Quick Start Guide Owners Manual EAGLE 3X: C157 C157 Analyzer Particle Filter Quick Start Guide Owners Manual EAGLE 2X: C155KIT C155 Analyzer EAGLE 3X: C157KIT

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EAGLE X: AT A GLANCE................................ LOWEST COST OF OWNERSHIP NO

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA - FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION Up to 6 WEEKS PRINTED RECORD (Optional)

More information

intrinsically safe detector for hydrocarbon gases

intrinsically safe detector for hydrocarbon gases portable flame ionisation detector intrinsically safe detector for hydrocarbon gases Intrinsically safe detector for hydrocarbon gases Monitoring gases in confined and potentially explosive situations

More information

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings Revamping Kits and Digital Solutions for quality improvement and energy savings Burners Sacmi for energy savings Complete range of burners for all fuel types. Heads specially designed for different capacities

More information

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System FEATURES: HIGH GAMMA SENSITIVITY MULTI-CHANNEL ANALYZER (MCA) WORKS WITH VARIETY OF PROBES RADIONUCLIDE LIBRARY TAILORED TO CUSTOMER REQUEST SIMULTANEOUSLY MEASURES ; DISPLAYS; ALARMS 1-3 SEPARATE DETECTORS

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the

More information

Rotary 1. Evaporators.

Rotary 1. Evaporators. Rotary 1 Evaporators www.wiggens.com STRIKE 300 - Rotary Evaporator A philosophy of safety The rotary evaporator STRIKE 300 combines excellent operating characteristics and high performance levels, all

More information

CRIOTEL. The complete solution for local and remote monitoring of cryogenic tanks under pressure

CRIOTEL. The complete solution for local and remote monitoring of cryogenic tanks under pressure CRIOTEL The complete solution for local and remote monitoring of cryogenic tanks under pressure AMBRA SISTEMI company, operating for over 20 years in electronic devices production, specifically for the

More information

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10

More information

VS LD series vertical steam sterilizers

VS LD series vertical steam sterilizers VS LD series vertical steam sterilizers Steelco vertical Steam Sterilizers VS LD series are designed to answer the typical sterilization needs of a laboratory: glassware, stainless steel instruments, culture

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION 12 WEEKS PRINTED RECORD (Optional) 4 CHANNEL

More information

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:

More information

GAS ANALYSIS / DETECTION Gas Detector

GAS ANALYSIS / DETECTION Gas Detector Eikon - Single gas recyclable personal monitor GAS ANALYSIS / DETECTION Tough and rugged Eikon is the durable single gas fixed life personal monitor that really lasts the course. Loud & Clear Alarms Easy

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges) External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2

More information

Accuracy by Design Products for the HVAC Professional

Accuracy by Design Products for the HVAC Professional Accuracy by Design Products for the HVAC Professional Greystone Energy Systems Inc., is one of North America s largest ISO registered manufacturers of HVAC sensors and transducers for Building Automation

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SIRA Certification Service Accredited to ISO/IEC 17065:2012 to provide product conformity Unit 6 Hawarden Industrial Park Hawarden Deeside

More information

Gilian Air Sampling Products. The World s Most Reliable Air Sampling Equipment

Gilian Air Sampling Products. The World s Most Reliable Air Sampling Equipment Gilian Air Sampling Products The World s Most Reliable Air Sampling Equipment Overview of Sensidyne Established in 1983 Joined the Schauenburg Group in 2008 Major Product Groups: Air Sampling * Fixed Gas

More information

Pressure measuring instruments

Pressure measuring instruments Data sheet testo 312-2 / -3 / -4 Pressure measuring instruments For gas and water installers testo 312-2 testo 312-3 testo 312-4 hpa bar C www.testo.com testo 312-2 / testo 312-3 Pressure meters for gas

More information

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS products index 2 expert nano 06 plus200 EXPERT DATALOGGER 24 ecp_ base4 u vd 40 PEV pulse 60 expert nano 200 NANO 1CF 08 Plus300 EXPERT

More information

icone plus Calorimeter

icone plus Calorimeter icone plus Calorimeter (ISO 5660 ASTM E1354) i series THE BENCHMARK IN FIRE TESTING the new benchmark in calorimetry Following a successful launch of the icone Calorimeter in 2013, the release of a new

More information

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345 External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery 99 Washington Street Melrose,

More information

PLC Control Touch-Screen

PLC Control Touch-Screen Almost all laboratory freeze-drying processes can be carried out using this basic unit and the wide range of accessories available. The 4K incorporates a stainless steel cooled trap that can be easily

More information

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C External Dimensions: B = 750 mm D = 700 mm H = 2100 mm Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm Capacity: 600 l Temperaturerange: 2 C to 20 C Housing galvanized sheet steel with high quality

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 63A Issue date 16 th June 2015 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44 (0)1244

More information

CTBTO ULTRA HIGH VOLUME AIR SAMPLER GLOBAL AIR SAMPLING SYSTEM UHV600 SERIES: 15 H.P. SYSTEM UHV600-15HP AND UHV600-15HP-20850

CTBTO ULTRA HIGH VOLUME AIR SAMPLER GLOBAL AIR SAMPLING SYSTEM UHV600 SERIES: 15 H.P. SYSTEM UHV600-15HP AND UHV600-15HP-20850 Rev.: 3 January 2018 UHV600 15 H.P. Series CTBTO ULTRA HIGH VOLUME AIR SAMPLER GLOBAL AIR SAMPLING SYSTEM UHV600 SERIES: 15 H.P. SYSTEM UHV600-15HP-41550 AND UHV600-15HP-20850 Optional radioiodine Collection

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Plasma Freezer with air circulation TC 516 acc. to DIN 58375 These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm

More information

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US. Flexible Schedule of Accreditation SIRA CERTIFICATION SERVICE. Issue No: 072A Issue date 23 rd March 2018 Unit 6 Hawarden Industrial Park Hawarden, CH5 3US, United Kingdom Contact: Mr A Myler Tel: +44

More information

Gas Technology Services

Gas Technology Services Gas Technology Services Gas Technology Services Gas Technology Services is a subsidiary of Australian technical consultancy Vipac Engineers & Scientists Ltd. Vipac is a leading testing laboratory, engineering

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption

More information

Microtherm Heat Stress WBGT

Microtherm Heat Stress WBGT Microtherm Heat Stress WBGT Introduction The Microtherm WBGT from Casella CEL is an ergonomically designed, compact, and rugged instrument designed to monitor heatstress potential of personnel in hot working

More information

3 3SP_O3_5 C Package

3 3SP_O3_5 C Package 15x15 O3 Sensor 5 ppm C Package 110-407 BENEFITS Small Size with Low Profile (20x20x3 mm) Long Life (10 years expected life) Fast Response (< 15 seconds) Low Power Consumption Individually Calibrated (NIST

More information

Platelet bags constant shaking for long periods of time.

Platelet bags constant shaking for long periods of time. Horizontal shakers for platelet bags APL-54 and APL-108 HORIZONTAL MOVEMENT AT A FIXED SPEED OF 66 R.P.M., LATERAL SHUFFLE OF 40 MM. APL-54 : CAPACITY FOR 54 PLATELET BAGS. APL-108 : CAPACITY FOR 108 PLATELET

More information

Operate the Mutli-Gas Monitor PID

Operate the Mutli-Gas Monitor PID TASK: Operate the Multi-Gas Monitor Learning Objective CONDITION: In a classroom environment, given a fully charged Multi-gas Monitor with the manufacturer operator s manual, all monitor components/accessories,

More information

Concise catalogue Water-Industry

Concise catalogue Water-Industry 2008 Concise catalogue Water-Industry One-channel instruments to measure ph, EC, DO and free chlorine, panel and wall-mounting version. Transmitters - controllers very easy to utilize, the customer does

More information

Monitores Personales. Personal Monitor

Monitores Personales. Personal Monitor Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,

More information

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective

More information

Tinytag Ultra Data Logger Manual

Tinytag Ultra Data Logger Manual Gemini Data Loggers Tinytag Ultra Data Logger Manual The name TINYTAG covers a range of miniature dataloggers used to aid the collection and monitoring of data. TINYTAG ULTRA loggers offer many features

More information

Mercury Vapor Monitor VM-3000

Mercury Vapor Monitor VM-3000 Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS)

More information

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40 Technical Description Laboratory Climate Test Chamber System Weiss Mat. No.:67592625 Type WKL 34/40 FACTS The test chambers types WTL/WKL with compact exterior dimensions were especially developed for

More information

Specifications Minimum Typical Maximum Unit

Specifications Minimum Typical Maximum Unit Temperature Probe Data Logger with LCD and USB Interface ORDERING INFORMATION Standard Data Logger (Data Logger, 1m Thermistor Probe, Software on CD and Battery) Replacement Battery LASREC028 LASACC001

More information

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence

More information

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS www.infragas.com INFRAGAS IR CATALYTIC GAS HEATERS WHO WE ARE Since 1971 INFRAGAS designes and produces infrared catalytic gas systems specific for surface

More information

EXPERIENCE IN INDUSTRIAL AND ANALYTIC FIELDS

EXPERIENCE IN INDUSTRIAL AND ANALYTIC FIELDS EXPERIENCE IN INDUSTRIAL AND ANALYTIC FIELDS Infrared Industries, Inc. (IRI) was founded in the late 1950s and initially produced infrared detecting elements, instruments, and control systems for the military

More information

Measuring Recording Online Monitoring Regulation Alarming

Measuring Recording Online Monitoring Regulation Alarming Measuring Recording Online Monitoring Regulation Alarming Temperature Humidity CO 2 Dew point Atmospheric pressure Analog signals Two-state inputs Pulses Battery operated recorders and printers Economical

More information

New European Cable Testing and Classification

New European Cable Testing and Classification New European Cable Testing and Classification THE BENCHMARK IN FIRE TESTING New European Cable Testing and Classification Cables will be tested using 5 test methods, and classified by extending the provisions

More information

CALIDUS tm the Modular micro Gas Chromatograph

CALIDUS tm the Modular micro Gas Chromatograph CALIDUS tm the Modular micro Gas Chromatograph Sample Processing Unit Plug & Play Programmed Temperature Column Modules Plug & Play Detector Modules Flame Ionization Thermal Conductivity A CALIDUS micro

More information

3SP_H2S_50 Package

3SP_H2S_50 Package 15x15 H2S Sensor 50 ppm Package 110-304 BENEFITS Small Size with Low Profile (20x20 x3.0mm) Long Life (10 years expected life) Fast Response (< 15 seconds) Low Power Consumption Individually Calibrated

More information

DESCRIPTION AND SPECIFICATION

DESCRIPTION AND SPECIFICATION DESCRIPTION AND SPECIFICATION GASFLOW MEASUREMENT EMITTER SENSOR SYSTEMS Sensor System Dynamic GUNYFLOW V10 Sensor System Dynamic GUNYFLOW V10 ATEX Safety Barrier SB V10 ATEX Central Unit GUNY-CPU V10

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

Product data sheet Palas Fidas 200 S

Product data sheet Palas Fidas 200 S Product data sheet Palas Fidas 200 S Applications Regulatory environmental monitoring in measuring networks Ambient air measurement campaigns Oriented indicative measurements (spot checks) Long-term studies

More information

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax erators / blood bank refrigerators / combined refrigerator-freezers / laboratory freezers /laboratory and pharmacy refrigerators Fri.med. Srl Via Riva, 26/19 14021 Buttigliera d Asti (AT) Italy Tel. +39

More information

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa Static differential pressure measuring instruments Pascal-ST/Z for low measurement ranges 0... +50 Pa oder 0... +200 Pa NOVASINA 2008 Agenda AGENDA Pascal-ST/Z series Measurement principle Highlights Technical

More information

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes CLEACOM Engineered System Solutions Established 24/7 technology for the separation of dust and fume during compounding processes Reduced consumption of resources with dry separation. Wet separation with

More information

Accurate. Reliable. Every Time. Air Measuring Instrumentation

Accurate. Reliable. Every Time. Air Measuring Instrumentation Accurate. Reliable. Every Time. Air Measuring Instrumentation Airflow History Service and Support You can expect fast turnaround times for calibration and repair service for your Airflow Instruments. Our

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING Cone Calorimeter (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test The

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

ROTARY EVAPORATORS EVAPORATION SOLUTIONS

ROTARY EVAPORATORS EVAPORATION SOLUTIONS ROTARY EVAPORATORS EVAPORATION SOLUTIONS WWW.LABTECHSRL.COM EVAPORATION SOLUTIONS The LabTech evaporation solutions introduce a new concept in routine distillation/evaporation processes: safety, efficiency

More information

THERMAX Efficiency Monitor

THERMAX Efficiency Monitor INSTALLATION & OPERATION INSTRUCTIONS THERMAX Efficiency Monitor Oil & Gas Fired Heating Equipment Efficiency Monitoring Instrument Important Safety Instructions Read and safe these instructions before

More information

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm External Dimensions: B = 600 mm D = 630 mm H = 2000 mm Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm Capacity: 328 l Temperaturerange: -15 C to -30 C Housing galvanized sheet steel with white

More information

A660 Air Conditioning Laboratory Unit

A660 Air Conditioning Laboratory Unit A660 Air Conditioning Laboratory Unit Figure 1: A660 Base Unit shown with all options fitted High accuracy wet and dry bulb sensors before and after each process to determine air condition. All processes

More information