Safety Standard for Automatic Residential Garage Door Operators. SUMMARY: The Consumer Product Safety Commission ( Commission or CPSC ) is

Size: px
Start display at page:

Download "Safety Standard for Automatic Residential Garage Door Operators. SUMMARY: The Consumer Product Safety Commission ( Commission or CPSC ) is"

Transcription

1 This document is scheduled to be published in the Federal Register on 09/02/2015 and available online at and on FDsys.gov CONSUMER PRODUCT SAFETY COMMISSION 16 CFR Part 1211 [Billing Code P] [Docket No. CPSC ] Safety Standard for Automatic Residential Garage Door Operators AGENCY: U.S. Consumer Product Safety Commission. ACTION: Notice of proposed rulemaking. SUMMARY: The Consumer Product Safety Commission ( Commission or CPSC ) is proposing to amend the regulations for Safety Standard for Automatic Residential Garage Door Operators to reflect changes made by Underwriters Laboratories, Inc. ( UL ), in the entrapment protection provisions in UL s standard UL 325, Sixth Edition, Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators and Systems. DATES: Submit comments by [INSERT DATE 75 DAYS AFTER DATE OF PUBLICATION IN THE FEDERAL REGISTER]. ADDRESSES: You may submit comments, identified by Docket No. CPSC , by any of the following methods: Electronic Submissions: Submit electronic comments to the Federal erulemaking Portal at: Follow the instructions for submitting comments. The Commission does not accept comments submitted by electronic mail ( ), except 1

2 through The Commission encourages you to submit electronic comments by using the Federal erulemaking Portal, as described above. Written Submissions: Submit written submissions by mail/hand delivery/courier to: Office of the Secretary, Consumer Product Safety Commission, Room 820, 4330 East West Highway, Bethesda, MD 20814; Telephone (301) Instructions: All submissions received must include the agency name and docket number for this notice. All comments received may be posted without change, including any personal identifiers, contact information, or other personal information provided, to: Do not submit confidential business information, trade secret information, or other sensitive or protected information that you do not want to be available to the public. If furnished at all, such information should be submitted in writing. Docket: For access to the docket to read background documents or comments received, go to: and insert the docket number CPSC , into the Search box, and follow the prompts. FOR FURTHER INFORMATION CONTACT: Vince Amodeo, Directorate for Engineering Sciences, Consumer Product Safety Commission, 5 Research Place Rockville, MD, 20850; Telephone (301) or vamodeo@cpsc.gov. SUPPLEMENTARY INFORMATION: A. Background The Commission has regulations for residential garage door operators ( GDOs ) to protect consumers from the risk of entrapment. 16 CFR part The Commission 2

3 first issued the GDO standard in 1991 at the direction of the Consumer Product Safety Improvement Act of 1990 ( Improvement Act ), Public Law No Section 203 of the Improvement Act mandated that the entrapment protection requirements of the 1988 version of UL s 325, Third Edition, Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators and Systems, be considered a consumer product safety rule under the Consumer Product Safety Act. Section 203(c) of the Improvement Act established procedures for the Commission to revise the Commission s GDO standard. When UL revises the entrapment protection requirements of UL 325, UL must notify the Commission of the revision, and that revision shall be incorporated in the consumer product safety rule unless, within 30 days of such notice, the Commission notifies [UL] that the Commission has determined that such revision does not carry out the purposes of subsection (b) [of section 203 of the Improvement Act which mandated the UL 325 entrapment protection requirements initially]. As provided in the Improvement Act, the Commission has revised the GDO standard after UL has notified the Commission of changes to UL 325 s entrapment protection requirements several times in the past. The Commission last updated the mandatory rule in 2007, to reflect changes made to the entrapment protection provisions of UL 325 up to that time. B. Changes to UL 325 and the Existing Regulation Since the last update to the current mandatory rule in 2007, UL has published 11 revisions to UL 325, including the publication of the Sixth Edition in October 2013, and another revision to the Sixth Edition in June On November 4, 2013, UL notified the CPSC that UL had revised the entrapment protection requirements of UL 325 and had 3

4 published a Sixth Edition of that standard on October 14, On June 4, 2015, UL notified the Commission that UL published a revision to UL 325 Sixth Edition on May 25, On November 27, 2013, and on June 24, 2015, CPSC staff submitted briefing packages to the Commission explaining the latest revisions to the UL standard and the basis for staff s conclusion that the revisions enhance entrapment protections and are likely to reduce the possibility that children will become entrapped by partially open garage doors. On December 3, 2013, and on June 30, 2015, the Commission voted to accept the revisions to UL 325, Sixth Edition. The Commission also directed staff to prepare and send to the Commission a draft revision of 16 CFR part 1211 that would include the revised UL requirements in the codified text of the existing rule. In accordance with the Commission s previous votes, the Commission is issuing this proposed rule that would amend the mandatory GDO rule at 16 CFR part 1211 to include the revisions to the entrapment protection requirements of UL 325. Since the last revision of the rule in 2007, UL has made several substantive changes to the entrapment protection requirements of UL 325. These changes allow for new technological advances but do not modify the requirements for GDOs. The proposed rule modifies appropriate sections of the Commission s GDO standard to incorporate the new UL requirements, as discussed in the summary of changes to the existing rule below. C. Description of the Proposed Rule All of the proposed revisions are in subpart A of the GDO standard. The Commission is not proposing any changes to the certification (subpart B) or recordkeeping (subpart C) provisions of the GDO standard. Proposed revisions to some 4

5 sections of the rule are fairly extensive. For those sections, and through of the existing regulation, the proposed rule would either revise portions of the existing regulation or replace those sections completely and renumber them. In addition, the proposed rule adds two new sections ( (unattended operation requirements) and (vertically moving combination rigid one-piece overhead residential garage door and operator system)). The proposal renumbers existing through regarding instructions, labeling, and marking to become through in the proposed rule. The proposed rule also includes some technical edits and revisions to correct typographical errors. UL added requirements for certain types of GDOs that were not previously covered by the GDO standard. Most of the proposed revisions to the GDO standard involve adding requirements for these types of GDOs and making changes related to these provisions. In addition, UL added requirements for unattended operation of GDOs and for wireless control and communications. Finally, UL made several editorial changes throughout the standard to provide better descriptions of the appropriate requirements and test conditions, and UL also revised dimensional tolerances on test fixtures so that the fixtures can be manufactured using generally available machine tools. As discussed in more detail below, the Commission proposes to incorporate these changes into the Commission s GDO standard at 16 CFR part GDOs that Open Horizontally. Because UL added requirements for GDOs that open horizontally, the Commission proposes revisions to differentiate between requirements for horizontal and vertical opening GDOs ( (d)). Entrapment protection requirements are similar for vertically and horizontally opening GDOs. UL 5

6 added and clarified test requirements to address entrapment protection for either vertical or horizontal movement and clarified wording throughout the standard, such as replacing downward movement with closing movement, and adding vertically or horizontally moving, where appropriate. Additionally, UL clarified secondary entrapment protection requirements for vertically and horizontally opening GDOs. The proposed rule incorporates these changes ( ). Combination Sectional Overhead GDOs. UL added requirements for combination sectional overhead GDOs, which are a door and operator combination, in which the door and hardware are an integral part of the operator, and in which the operator does not exert a driving force on the door in the closing direction. The proposed rule incorporates these changes ( (c)). Under UL s revised provisions, this type of GDO must comply with the common requirements for GDOs; plus, they must comply with the requirements found in the American National Standard/Door and Access Systems Manufacturers ANSI/DASMA , Specifications for Sectional Doors, 2004 revision, dated October 22, 2004, which the Commission proposes to incorporate by reference in the proposed rule ( (c)). ANSI/DASMA provides requirements for installation/operation, maintenance, durability, and identification of GDO systems with the name and address of the door system manufacturer, loads, in addition to general requirements. This ANSI/DASMA standard is available from ANSI/DASMA, or the standard may be examined at the offices of the Federal Register. Additionally, the revised UL standard requires that the instructions for combination sectional overhead GDOs must specify: (1) the operator by manufacturer and model; (2) the doors by manufacturer, model, and maximum and minimum door 6

7 width and height required for compliance to the entrapment protection requirements; (3) the hardware required to meet the entrapment protection requirements ( (a)(13)); and (4) how to properly counterbalance the door (( (a)(14)). Finally, combination sectional overhead GDOs must be provided with permanent labels that contain specific warnings ( (k)) and markings ( (m)). The proposed rule includes these requirements in the sections indicated. Unattended Operation of GDOs. UL added requirements for unattended operation of GDOs, which is permitted if additional safety features are provided. The proposed rule includes these requirements (new ). Under UL s revised provisions, unattended operation is allowable only if proper installation instructions and markings are provided. Unattended GDOs must require one or more intentional actions to function and must require an audible and visual alarm that must signal for 5 seconds before door movement. Unattended operation is not permitted on one-piece or swinging garage doors. The word bulb is changed to light to address newer technologies that may use LEDs that may not be considered bulbs and clarifies that the visual or audio alarm during unattended operation does not require monitoring. Combination Rigid One-Piece Overhead GDOs. UL added requirements for combination rigid one-piece overhead GDOs, which are a door and operator combination in which the door is constructed of one rigid piece. The proposed rule includes these requirements (new ). Under UL s revised provisions, this type of GDO must comply with the common requirements for GDOs; plus, the speed of the door edge during movement must not exceed 6 inches per second. This type of GDO also must provide two additional independent secondary entrapment-protection devices, including a 7

8 minimum of two sensors. Additionally, these GDOs must provide a means of mechanically detaching both door operators from the door and must have an interlock to de-energize the operator when detached. Finally, the installation instructions for combination rigid one-piece GDOs must specify attachment points for installation. The proposed rule includes these requirements for instructions ( (b)(2)(13)). Wireless Control and Communication. UL added requirements for wireless control ( (d) and (f)), including additional tests for battery operation ( (g)) and wireless communication ( (h)). The proposed rule includes these requirements at the sections indicated. Photoelectric Sensors. UL added requirements for alternate sources of light for the photoelectric sensor ambient light test. The proposed rule includes these requirements ( (e)(2)). The current test method specifies a specific DXC-RFL-2 flood lamp, which is becoming difficult to obtain in the marketplace. Instead, the proposed requirement would specify the minimum required wattage (500W) and maximum color temperature (3600K) of the bulb, to allow for available light sources without affecting the test results. UL added a new test method for GDOs that use an array of vertical photoelectric sensors as a non-contact external entrapment protection device. The proposed rule includes this new test method ( (d)(4) and new paragraph (f)). The new method verifies that the vertical sensors function properly. Clarifications. UL made several clarifications throughout the standard to improve clarity and describe test conditions better. The proposed rule includes these clarifications: 8

9 Electronic instructions ( (a)(10)) may be provided on alternate sources, such as CD-ROM, USB flash drive, or company website. For GDOs for one-piece doors that have an unattended operation function, certain markings are not required if the GDO automatically senses door operation ( (b)(1)(ii), (h), and (m)), The requirements for UL markings for voltage, frequency, and input are clarified ( (b)(3) and (4)). UL marking requirements for risk of entrapment on GDOs that have user adjustments ( (i)) shall be located where visible to the user when making adjustments. Requirements for the external entrapment protection device (i.e., photoelectric sensor and edge sensor) test criteria ( (b), (c), and (e) and (d)(4)) are clarified, and the requirements for determining whether the system is operating normally before and after each test are made consistent throughout the standard. The requirements for the switch or relay used in the entrapment protection circuit ( (f)) are clarified by stating that the switch or relay must be capable of operating at a minimum cycling of 100,000 cycles, as intended in the GDO without failing, and that when/if failure does occur in actual use (at any cycle count), failure shall result in preventing further operation of the door. The Commission requests comments on whether the codification in the proposed rule accurately reflects the changes to the entrapment protection provisions of UL

10 D. Incorporation by Reference The proposed rule would update the existing incorporations by reference in the mandatory rule to the most recent version of the appropriate voluntary standard, as follows: NFPA 70 (The standard addresses the installation of electrical conductors, equipment, and raceways; signaling and communications conductors, equipment, and raceways; and optical fiber cables and raceways in commercial, residential, and industrial occupancies.)( (c)); UL 991 (The requirements apply to controls that employ solid-state devices and are intended for specified safety-related protective functions.)( (c) and (c)); UL 1998 (These requirements apply to non-networked embedded microprocessor software whose failure is capable of resulting in a risk of fire, electric shock, or injury to persons.)( (d)); and UL 746C (These requirements cover parts made of polymeric materials that are used in electrical equipment and describe the various test procedures and their use in the testing of such parts and equipment.)( (d) and (e), and (c)(2)). In addition, (c) of the proposed rule would add a new incorporation by reference for ANSI/DASMA The Office of the Federal Register ( OFR ) has regulations concerning incorporation by reference. 1 CFR part 51. The OFR recently revised these regulations to require that, for a proposed rule, agencies must discuss in the preamble to the NPR, the 10

11 ways that the materials the agency proposes to incorporate by reference are reasonably available to interested persons or how the agency worked to make the materials reasonably available. In addition, the preamble to the proposed rule must summarize the material. 1 CFR 51.5(a). In accordance with the OFR s requirements, this section and section C of this preamble summarize the provisions of the voluntary standards that the Commission proposes to incorporate by reference and to update: Specifications for Sectional Doors, ANSI/DASMA ANSI/DASMA is copyrighted. Copies may be obtained from the Door and Access Systems Manufacturers Association, International, 1300 Sumner Avenue, Cleveland, OH , telephone (216) , or online at: National Electrical Code, NFPA 70, 2014 edition. NFPA 70 is copyrighted. Copies may be obtained from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA (800) Standard for Safety for Tests for Safety-Related Controls Employing Solid-State Devices, UL 991, Third Edition, dated October 22, Standard for Safety for Software in Programmable Components, UL 1998, Third Edition, dated December 18, Standard for Safety for Polymeric Materials Use in Electrical Equipment Evaluations, UL 746C, Sixth Edition, dated September 10,

12 The UL standards listed above are copyrighted. For the UL standards, may be obtained online at: One may also inspect a copy of all of the above-referenced standards at CPSC s Office of the Secretary, U.S. Consumer Product Safety Commission, Room 820, 4330 East West Highway, Bethesda, MD 20814, Telephone: (301) E. Effective Date The requirements for residential GDOs in UL 325, Sixth Edition are currently in effect. Based on reports from industry representatives, all known manufacturers and importers currently conform to the provisions. Therefore, the Commission is proposing that the effective date of the rule, if finalized, would be 30 days from the date of publication of the final rule in the Federal Register. This effective date would not adversely affect the cost or availability of conforming GDOs. 12

13 F. Regulatory Flexibility Act The Regulatory Flexibility Act ( RFA ) generally requires that agencies review proposed and final rules for the rules potential economic impact on small entities, including small businesses, and prepare regulatory flexibility analyses. 5 U.S.C. 603 and 604. Because the existing level of conformance with the revisions to UL 325, Sixth Edition, is unanimous, and no new compliance costs or other burdens would be associated with the proposed amendment, the Commission certifies under the RFA that the rule would not likely have a significant impact on a substantial number of small businesses or other small entities. Under section 605(b) of the RFA, 5 U.S.C. 605(b), the Commission certifies that this proposed rule would not have a significant impact on a substantial number of small entities. G. Environmental Considerations The Commission s regulations provide a categorical exclusion for Commission rules from any requirement to prepare an environmental assessment or an environmental impact statement because the rules have little or no potential for affecting the human environment. 16 CFR (c)(2). This proposed rule falls within the categorical exclusion, so no environmental assessment or environmental impact statement is required. The Commission s regulations state that safety standards for products normally have little or no potential for affecting the human environment. 16 CFR (c)(1). Nothing in this proposed rule alters that expectation. 13

14 H. Preemption The Improvement Act contains a preemption provision that states: those provisions of laws of States or political subdivisions which relate to the labeling of automatic residential garage door openers and those provisions which do not provide at least the equivalent degree of protection from the risk of injury associated with automatic residential garage door openers as the consumer product safety rule are subject to preemption under 15 U.S.C Public Law No , section 203(f). List of Subjects in 16 CFR Part 1211 Consumer protection, Imports, Incorporation by reference, Labeling, Reporting and recordkeeping requirements. For the reasons set forth in the preamble, the Commission proposes to amend subpart A of 16 CFR part 1211, as follows: PART 1211 SAFETY STANDARDS FOR AUTOMATIC RESIDENTIAL GARAGE DOOR OPERATORS 1. The authority citation for part 1211 continues to read as follows: Authority: Sec. 203 of Pub. L , 104 Stat. 3110; 15 U.S.C and Amend by revising paragraph (c) to read as follows: Definition. * * * * * 14

15 (c) Is intended to be employed in ordinary locations in accordance with the National Electrical Code, NFPA 70, 2014 edition. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA , Telephone: (800) Copies may be inspected at the Consumer Product Safety Commission, Office of the Secretary, 4330 East West Highway, Bethesda, MD or at the National Archives and Records Administration (NARA. For information on the availability of this material at NARA, call (202) , or go to: 3. Amend by revising paragraph (c) to read as follows: General requirements for protection against risk of injury. * * * * * (c) An electronic or solid-state circuit that performs a back-up, limiting, or other function intended to reduce the risk of fire, electric shock, or injury to persons, including entrapment protection circuits, shall comply with the requirements in the Standard for Safety for Tests for Safety-Related Controls Employing Solid-State Devices, UL 991, Third Edition, dated October 22, 2004, including environmental and stress tests appropriate to the intended usage of the end-product. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained online at Copies may be inspected at the Consumer Product Safety Commission, Office of the Secretary, 4330 East West Highway, Bethesda, MD or at the National Archives and Records 15

16 Administration (NARA). For information on the availability of this material at NARA, call , or go to: 4. Amend by revising paragraphs (a)(1) and (6) and (b)(3) to read as follows: General testing parameters. (a) * * * (1) With regard to electrical supervision of critical components, an operator being inoperative with respect to closing movement of the door meets the criteria for trouble indication. * * * * * (6) When a Computational Investigation is conducted, λ p shall not be greater than 6 failures/10 6 hours for the entire system. For external secondary entrapment protection devices or systems that are sold separately, λ p shall not be greater than 0 failures/10 6 hours. For internal secondary entrapment protection devices or systems whether or not they are sold separately, λ p shall not be greater than 0 failures/10 6 hours. The operational test is conducted for 14 days. An external secondary entrapment protection device or system that is sold separately, and that has a λ p greater than 0 failures/10 6 hours meets the intent of the requirement when for the combination of the operator and the specified external secondary entrapment protection device λ p does not exceed 6 failures/10 6 hours. See (j) through (l). * * * * * (b) * * * 16

17 (3) During the Power Cycling Safety for Tests in accordance with the Standard for Safety for Tests for Safety-Related Controls Employing Solid-State Devices, UL 991, Third Edition, dated October 22, This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained online at Copies may be inspected at the Consumer Product Safety Commission, Office of the Secretary, 4330 East West Highway, Bethesda, MD or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call , or go to: 5. Revise to read as follows: General entrapment protection requirements. (a) A residential garage door operator system shall be provided with inherent primary entrapment protection that complies with the requirements as specified in (b) In addition to the inherent primary entrapment protection as required by paragraph (a) of this section, a vertically moving residential garage door operator shall comply with one of the following: (1) Shall be constructed to: (i) Require constant pressure on a control intended to be installed and activated within line of sight of the door to lower the door; (ii) Reverse direction and open the door to the upmost position when constant pressure on a control is removed prior to operator reaching its lower limit, and 17

18 (iii) Limit a portable transmitter, when supplied, to function only to cause the operator to open the door; (2) Shall be provided with a means for connection of an external secondary entrapment protection device as described in , , and ; or (3)(i) Shall be provided with an inherent secondary entrapment protection device as described in (a), (c), (f), , and and is: (A) A combination sectional overhead garage door operator system as described in (c); and (B) For use only with vertically moving garage doors. (ii) With respect to (b)(3)(i)(A), trolley-driven operators do not meet the definition of a combination sectional overhead garage door operator system. (c) In the case of a vertically moving combination sectional overhead garage door operator system, the door shall comply with the requirements in Specifications for Sectional Doors, ANSI/DASMA 102, 2004 revision, dated October 22, This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from the Door and Access Systems Manufacturers Association, International, 1300 Sumner Avenue, Cleveland, OH , telephone (216) , or online at Copies may be inspected at the Consumer Product Safety Commission, Office of the Secretary, 4330 East West Highway, Bethesda, MD or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, 18

19 call , or go to: (d) In addition to the inherent primary entrapment protection as required by (a), a horizontally sliding residential garage door operator shall comply with one of the following: (1) Shall be constructed to: (i) Require constant pressure on a control to close the door; (ii) Reverse direction and open the door a minimum of 2 in (50.8 mm) when constant pressure on a control is removed prior to operator reaching its position limit; and (iii) Stop the door if a second obstruction is detected in the reverse direction. (2) Shall be provided with a means for connection of an external secondary entrapment protection device for each leading edge as described in (e) A mechanical switch or a relay used in an entrapment protection circuit of an operator shall withstand 100,000 cycles of operation controlling a load no less severe (voltage, current, power factor, inrush and similar ratings) than it controls in the operator, and shall function normally upon completion of the test. (f) In addition to complying with paragraph (e) of this section, in the event of a malfunction of a switch or relay (open or short) described in paragraph (c) of this section results in loss of any entrapment protection required by (a), (b)(7), (c)(7), (a), or (b), the door operator shall become inoperative at the end of the opening or closing operation, the door operator shall move the door to, and stay within, 1 foot (305 mm) of the uppermost position. 6. Revise to read as follows: 19

20 Inherent primary entrapment protection requirements. (a) General requirements. A vertically moving residential garage door operator system shall be supplied with inherent primary entrapment protection that complies with the requirements as specified in paragraph (b) of this section. A horizontally sliding residential garage door operator system shall be supplied with inherent primary entrapment protection that complies with the requirements as specified in paragraph (c) of this section. (b) Inherent primary entrapment protection, vertically moving doors. (1)(i) For a vertically moving residential garage door operator system, other than for the first 1 foot (305mm) of door travel from the full upmost position both with and without any secondary external entrapment protection device functional, the operator of a downward moving residential garage door shall initiate reversal of the door within 2 seconds of contact with the obstruction as specified in subparagraph (b)(3) of this section. After reversing the door, the operator shall return the door to, and stop at, the full upmost position. Compliance shall be determined in accordance with paragraphs (b)(3) through (10) of this section. (ii) The door operator is not required to return the door to, and stop the door at, the full upmost position when the operator senses a second obstruction during the upward travel. (iii) The door operator is not required to return the door to, and stop the door at, the full upmost position when a control is actuated to stop the door during the upward travel but the door can not be moved downward until the operator reverses the door a minimum of 2 inches (50.8 mm). 20

21 (2) The test shall be performed on a representative operating system installed in accordance with the manufacturer s installation instructions with the operator exerting a 25-lbf ( N) pull or its rated pull, whichever is greater. (3)(i) A solid object is to be placed on the floor of the test installation and at various heights under the edge of the door and located in line with the driving point of the operator. When tested on the floor, the object shall be 1 inch (25.4 mm) high. In the test installation, the bottom edge of the door under the driving force of the operator is to be against the floor when the door is fully closed. (ii) For operators other than those attached to the door, a solid object is not required to be located in line with the driving point of the operator. The solid object is to be located at points at the center, and within 1 foot of each end of the door. (iii) To test operators for compliance with requirements in paragraphs (b)(1)(iii), (b)(7)(iii), and (b)(8)(iii) of this section and (c), a solid rectangular object measuring 4 inches (102 mm) high by 6 inches (152 mm) wide by a minimum of 6 inches (152 mm)long is to be placed on the floor of the test installation to provide a 4-inch (102 mm) high obstruction when operated from a partially open position. (4) An operator is to be tested for compliance with paragraph (b)(1) of this section for 50 open-and-close cycles of operation while the operator is connected to the type of residential garage door with which it is intended to be used or with the doors specified in paragraph (b)(6) of this section. For an operator having a force adjustment on the operator, the force is to be adjusted to the maximum setting or at the setting that represents the most severe operating condition. Any accessories having an effect on the 21

22 intended operation of entrapment protection functions that are intended for use with the operator, are to be attached and the test is to be repeated for one additional cycle. (5) For an operator that is to be adjusted (limit and force) according to instructions supplied with the operator, the operator is to be tested for 10 additional obstruction cycles using the solid object described in paragraph (b)(3) of this section at the maximum setting or at the setting that represents the most severe operating condition. (6) For an operator that is intended to be used with more than one type of door, one sample of the operator is to be tested on a sectional door with a curved track and one sample is to be tested on a one-piece door with jamb hardware and no track. For an operator that is not intended for use on either or both types of doors, a one-piece door with track hardware or a one-piece door with pivot hardware shall be used for the tests. For an operator that is intended for use with a specifically dedicated door or doors, a representative door or doors shall be used for the tests. See the marking requirements at (7)(i) An operator, employing an inherent entrapment protection system that measures or monitors the actual position of the door, shall initiate reversal of the door and shall return the door to, and stop the door at, the full upmost position in the event the inherent door operating profile of the door differs from the originally set parameters. The entrapment protection system shall measure or monitor the position of the door at increments not greater than 1 inch (25.4 mm). (ii) The door operator is not required to return the door to, and stop the door at, the full upmost position when an inherent entrapment circuit senses an obstruction during the upward travel. 22

23 (iii) The door operator is not required to return the door to, and stop the door at, the full upmost position when a control is actuated to stop the door during the upward travel but the door can not be moved downward until the operator reverses the door a minimum of 2 inches (50.8 mm). (8)(i) An operator, using an inherent entrapment protection system that does not measure or monitor the actual position of the door, shall initiate reversal of the door and shall return the door, to and stop the door at the full upmost position, when the lower limiting device is not actuated in 30 seconds or less following the initiation of the close cycle. (ii) The door operator is not required to return the door to, and stop the door at, the full upmost position when an inherent entrapment circuit senses an obstruction during the upward travel. When the door is stopped manually during its descent, the 30 seconds shall be measured from the resumption of the close cycle. (iii) The door operator is not required to return the door to, and stop the door at, the full upmost position when a control is actuated to stop the door during the upward travel but the door can not be moved downward until the operator reverses the door a minimum of 2 inches (50.8 mm). When the door is stopped manually during its descent, the 30 seconds shall be measured from the resumption of the close cycle. (9) To determine compliance with paragraph (b)(7) or (8) of this section, an operator is to be subjected to 10 open-and-close cycles of operation while connected to the door or doors specified in paragraphs (b)(4) and (6) of this section. The cycles are not required to be consecutive. Motor cooling-off periods during the test meet the intent of the requirement. The means supplied to comply with the requirement in paragraph (b)(1) of 23

24 this section and (a) or (b) are to be defeated during the test. An obstructing object is to be used so that the door is not capable of activating a lower limiting device. (10) During the closing cycle referred to in paragraph (b)(9) of this section, the system providing compliance with paragraphs (b)(1) and (7) of this section or paragraphs (b)(1) and (8) of this section shall function regardless of a short- or open-circuit anywhere in any low-voltage external wiring, any external entrapment devices, or any other external component. (c) Inherent primary entrapment protection, horizontally sliding doors. (1)(i) For a horizontally sliding residential garage door operator system, other than for the first 1 foot (305mm) of door travel from the full closed position both with and without any external entrapment protection device functional, the operator of a closing residential garage door shall initiate reversal of the door within 2 seconds of contact with the obstruction as specified in paragraph (c)(3) of this section. After reversing the door, the operator shall open the door a minimum of 2 inches (50.8 mm) from the edge of the obstruction. Compliance shall be determined in accordance with paragraphs (c)(2) through (10) of this section. (ii) The door operator is not required to open the door a minimum 2 inches (50.8 mm) when the operator senses a second obstruction during the closing direction of travel. (iii) The door operator is not required to open the door a minimum 2 inches (50.8 mm) when a control is actuated to stop the door during movement towards the open position but the door can not be moved towards the open position until the operator reverses the door a minimum of 2 inches (50.8 mm). 24

25 (2) The test shall be performed on a representative operating system installed in accordance with the manufacturer s installation instructions with the operator exerting a 25-lbf ( N) pull or its rated pull, whichever is greater. (3)(i) A solid object is to be placed on the floor of the test installation and rigidly supported within the bottom track and then repeated with the solid object placed on the floor and rigidly supported external to the track. The test shall then be repeated with the solid object rigidly supported at heights of 1 ft (305 mm), 3 ft (914 mm), 5 ft (1524 mm), and within 1 ft (305 mm) of the top edge. The object shall be 1 inch (25.4 mm) in width. (ii) For operators other than those attached to the door, a solid object is not required to be located in line with the driving point of the operator. The solid object is to be located at points at the center and within 1 ft of each end of the door opening. (iii) To test operators for compliance with paragraphs (c)(1)(iii), (c)(7)(iii), and (c)(8)(iii) of this section, and (c), a solid rectangular object measuring 4 inches (102 mm) high by 6 inches (152 mm) wide by a minimum of 6 in (152 mm) long is to be placed on the floor of the test installation to provide a 4 in (102 mm) high obstruction when operated from a partially open position with the test repeated with the bottom edge of the obstruction rigidly supported at heights of 1 ft (305 mm), 3ft (914 mm), 5ft (1524 mm), and within 1 ft (305 mm) of the top edge. (4) An operator is to be tested for compliance with paragraph (c)(1) of this section for 50 open-and-close cycles of operation while the operator is connected to the type of residential garage door with which it is intended to be used or with the doors specified in paragraph (c)(6) of this section. For an operator having a force adjustment on the operator, the force is to be adjusted to the maximum setting or at the setting that 25

26 represents the most severe operating condition. Any accessories having an effect on the intended operation of entrapment protection functions that are intended for use with the operator, are to be attached and the test is to be repeated for one additional cycle. (5) For an operator that is to be adjusted (limit and force) according to instructions supplied with the operator, the operator is to be tested for 10 additional obstruction cycles using the solid object described in paragraph (c)(3) of this section at the maximum setting or at the setting that represents the most severe operating condition. (6) For an operator that is intended to be used with more than one type of door, one sample of the operator is to be tested on a sectional door with a curved track and one sample is to be tested on a one-piece door with jamb hardware and no track. For an operator that is not intended for use on either or both of these types of doors, a one-piece door with track hardware or a one-piece door with pivot hardware shall be used for the tests. For an operator that is intended for use with a specifically dedicated door or doors, a representative door or doors shall be used for the tests. See the marking requirements in (7)(i) An operator, employing an inherent entrapment protection control that measures or monitors the actual position of the door, shall initiate reversal of the door and shall return the door to, and stop the door at, the fully closed position in the event the inherent door operation "profile" of the door differs from the originally set parameters. The system shall measure or monitor the position of the door at increments not greater than 1 inch (25.4 mm). 26

27 (ii) The door operator is not required to open the door a minimum 2 inches (50.8 mm) when an inherent entrapment circuit senses an obstruction during the reversing travel. (iii) The door operator is not required to open the door a minimum 2 inches (50.8 mm) when a control is actuated to stop the door during the opening direction but the door can not be moved in the closing direction until the operator reverses the door a minimum of 2 inches (50.8 mm). (8)(i) An operator, using an inherent entrapment protection system that does not measure or monitor the actual position of the door, shall initiate reversal of the door and shall open the door a minimum 2 inches (50.8 mm) when the closed position limit device is not actuated within 30 seconds or less following the initiation of the close cycle. (ii) The door operator is not required to open the door a minimum 2 inches (50.8 mm) when an inherent entrapment circuit senses an obstruction during the reversing travel. (iii) The door operator is not required to open the door a minimum 2 inches (50.8 mm) when a control is actuated to stop the door during the opening direction but the door can not be moved in the closing direction until the operator has reversed the door a minimum of 2 inches (50.8 mm). When the door is stopped manually during its closing, the 30 seconds shall be measured from the resumption of the close cycle. (9) To determine compliance with paragraph (c)(7) or (8) of this section, an operator is to be subjected to 10 open-and-close cycles of operation while connected to the door or doors specified in paragraphs (c)(4) and (6) of this section. The cycles are not required to be consecutive. Motor cooling-off periods during the test meet the intent of the 27

28 requirement. The means supplied to comply with paragraph (c)(1) of this section and (b) are to be inoperative or defeated during the test. An obstructing object is to be used so that the door is not capable of activating a position limiting device. (10) During the closing cycle referred to in paragraph (c)(9) of this section, the system providing compliance with paragraphs (c)(1) and (7) of this section or paragraphs (c)(1) and (8) of this section shall function regardless of a short- or open-circuit anywhere in any low-voltage external wiring, any external entrapment devices, or any other external component. 7. Revise to read as follows: Secondary entrapment protection requirements. (a)(1) For a vertically moving door operator, a secondary entrapment protection device supplied with, or as an accessory to, an operator shall consist of: (i) An external photoelectric sensor that when activated results in an operator that is closing a door to reverse direction of the door, returns the door to, and stops the door at the fully open position, and the sensor prevents an operator from closing an open door, (ii) An external edge sensor installed on the edge of the door that, when activated results in an operator that is closing a door to reverse direction of the door, returns the door to, and stops the door at the fully open position, and the sensor prevents an operator from closing an open door, (iii) An inherent door sensor independent of the system used to comply with that, when activated, results in an operator that is closing a door to reverse direction of the door and the sensor prevents an operator from closing an open door, or 28

29 (iv) Any other external or internal device that provides entrapment protection equivalent to paragraph (a)(1)(i), (ii), or (iii) of this section. (2) The door operator is not required to return the door to, and stop the door at, the fully open position when an inherent entrapment circuit senses an obstruction during the opening travel. (3) The door operator is not required to return the door to, and stop the door at, the fully open position when a control is actuated to stop the door during the opening travel - but the door cannot be moved towards the closing direction until the operator has reversed the door a minimum of 2 inches (50.8 mm). (b) For horizontal sliding garage door operators, a secondary entrapment protection device supplied with, or as an accessory to, an operator shall consist of: (1) An external photoelectric sensor that, when activated, results in an operator that is closing or opening a door to reverse direction of the door for a minimum of 2 inches (50.8 mm); or (2) An external edge sensor installed on the edge of the door that, when activated, results in an operator that is closing or opening a door to reverse direction of the door for a minimum of 2 inches (50.8 mm). (c) With respect to paragraphs (a) and (b) of this section, the operator shall monitor for the presence and correct operation of the device at least once during each close cycle. Should the device not be present or a fault condition occurs which precludes the sensing of an obstruction, including an interruption of the wireless signal to the wireless device or an open or short circuit in the wiring that connects an external entrapment protection 29

30 device to the operator and device's supply source, the operator shall be constructed such that: (1) For a vertically moving door, the closing door shall open and an open door shall not close more than 1 foot (305 mm) below the upmost position; (2) For a horizontally sliding door, the door shall not move in the opening or closing direction; or (3) The operator shall function as required by (b)(1). (d) An external entrapment protection device or system, when employing a wireless control, shall comply with paragraph (e) of this section when installed at its farthest distance from the operator as recommended in the installation instructions. (e) An external entrapment protection device shall comply with the applicable requirements in , and (f) An inherent secondary entrapment protection device shall comply with the applicable requirements in Software used in an inherent entrapment protection device shall comply with the Standard for Safety for Software in Programmable Components, UL 1998, Third Edition, December 18, This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained online at Copies may be inspected at the Consumer Product Safety Commission, Office of the Secretary, 4330 East West Highway, Bethesda, MD or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call , or go to: 30

31 8. Amend by: a. Revising paragraph (a); b. Revising paragraph (b)(2); and c. Revising paragraph (c). The revisions read as follows: Additional entrapment protection requirements. (a) A means to manually detach the door operator from the door shall be supplied. The gripping surface (handle) shall be colored red and shall be easily distinguishable from the rest of the operator. It shall be capable of being adjusted to a height of 6 feet (1.8 m) above the garage floor when the operator is installed according to the instructions specified in (a)(2). The means shall be constructed so that a hand firmly gripping it and applying a maximum of 50 pounds (223 N) of force shall detach the operator with the door obstructed in the down position. The obstructing object, as described in (b)(3)(i), is to be located in several different positions. A marking with instructions for detaching the operator shall be provided as required by (a), (b), and (j), as applicable. (b) * * * (2) The door is capable of being moved to the 2-inch (50.8-mm) point from any position between closed and the 2-inch (50.8-mm) point. (c) Actuation of a control that initiates movement of a door shall stop and may reverse the door on the closing cycle. On the opening cycle, actuation of a control shall stop the door but not reverse it. * * * * * 31

Federal Register / Vol. 81, No. 67 / Thursday, April 7, 2016 / Rules and Regulations

Federal Register / Vol. 81, No. 67 / Thursday, April 7, 2016 / Rules and Regulations 20224 Federal Register / Vol. 81, No. 67 / Thursday, April 7, 2016 / Rules and Regulations No. SB 2016 72 50 00 1/00, dated January 21, 2016, onto any engine. CONSUMER PRODUCT SAFETY COMMISSION (g) Alternative

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 19, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 19, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: March 19, 2018 STANDARD INFORMATION Standard Number: UL 325 Standard Name: Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems Standard Edition

More information

UL Revision 5. - Commercial Door Installations -

UL Revision 5. - Commercial Door Installations - UL325 2010 Revision 5 - Commercial Door Installations - UL325 - Scope - Door, Drapery, Gate, Louver, and Window Operators and Systems Covers electric operators for doors, draperies, gates, louvers, windows

More information

[Docket No. FAA ; Directorate Identifier 2004-CE-25-AD; Amendment ; AD ]

[Docket No. FAA ; Directorate Identifier 2004-CE-25-AD; Amendment ; AD ] [Federal Register: October 22, 2004 (Volume 69, Number 204)] [Rules and Regulations] [Page 61993-61997] From the Federal Register Online via GPO Access [wais.access.gpo.gov] [DOCID:fr22oc04-3] DEPARTMENT

More information

Airworthiness Directives; Kidde Aerospace Part Number (P/N) Hand-Held Halon Fire Extinguishers

Airworthiness Directives; Kidde Aerospace Part Number (P/N) Hand-Held Halon Fire Extinguishers [Federal Register: January 7, 2004 (Volume 69, Number 4)] [Rules and Regulations] [Page 864-867] From the Federal Register Online via GPO Access [wais.access.gpo.gov] [DOCID:fr07ja04-4] DEPARTMENT OF TRANSPORTATION

More information

[Docket No. FAA ; Directorate Identifier 2012-NM-176-AD] Airworthiness Directives; DASSAULT AVIATION Airplanes

[Docket No. FAA ; Directorate Identifier 2012-NM-176-AD] Airworthiness Directives; DASSAULT AVIATION Airplanes This document is scheduled to be published in the Federal Register on 05/21/2013 and available online at http://federalregister.gov/a/2013-12077, and on FDsys.gov [4910-13-P] DEPARTMENT OF TRANSPORTATION

More information

[Docket No. FAA ; Product Identifier 2017-NE-02-AD; Amendment ; AD ]

[Docket No. FAA ; Product Identifier 2017-NE-02-AD; Amendment ; AD ] [Federal Register Volume 82, Number 189 (Monday, October 2, 2017)] [Rules and Regulations] [Pages 45710-45712] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC Subject C100 ULC-G.5.2 CCF7 S500F/SC2 October 28, 2014 CERTIFICATION BULLETIN 2014-07 Second Edition ULC/ORD-C100-13 Smoke Control System Equipment To: Members of the ULC Advisory Committee Members

More information

L'HOTELLIER

L'HOTELLIER Page 1 2011-11-04 L'HOTELLIER Amendment 39-16703 Docket No. FAA-2011-0506; Directorate Identifier 2010-SW-020-AD PREAMBLE Applicability: Portable Halon 1211 fire extinguisher, part number 863520-00, with

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARD INFORMATION Standard Number: UL 412 Standard Name: Refrigeration Unit Coolers Standard Edition and Issue Date: 5 th Edition Dated August 22,

More information

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS Chapter 5 NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS When writing specifications, considerations should be given to the following: he Door should not form the only entrance/exit to an

More information

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES ANSI/DASMA 204-2004 AMERICAN NATIONAL STANDARD STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES Door & Access Systems Manufacturers Association, International Sponsor: 1300 Sumner Ave Cleveland, Ohio 44115-2851

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARD INFORMATION Standard Number: UL 1206 Standard Name: Standard for Electric Commercial Clothes-Washing Equipment Standard Edition and Issue Date:

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

DEPARTMENT OF VETERANS AFFAIRS SUMMARY: The Department of Veterans Affairs (VA) proposes to amend its

DEPARTMENT OF VETERANS AFFAIRS SUMMARY: The Department of Veterans Affairs (VA) proposes to amend its This document is scheduled to be published in the Federal Register on 07/15/2014 and available online at http://federalregister.gov/a/2014-16414, and on FDsys.gov DEPARTMENT OF VETERANS AFFAIRS 8320-01

More information

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule NEW YORK CITY FIRE DEPARTMENT Notice of Public Hearing and Opportunity to Comment on Proposed Rule What are we proposing? The Fire Department is proposing to comprehensively update Section 3004-01 of Title

More information

NFPA 72 Code Changes vs 2013

NFPA 72 Code Changes vs 2013 NFPA 72 Code Changes - 2010 vs 2013 AFAA-NE Westborough, MA February 7, 2018 Richard Roux NFPA 72 National Fire Alarm and Signaling Code Overview and 2013 Changes NFPA 72 1993 Edition Aug 20, 1993 1996

More information

Standards in Security Shutters & Fire Shutters (UK & USA)

Standards in Security Shutters & Fire Shutters (UK & USA) Standards in Security Shutters & Fire Shutters (UK & USA) Jason Powell 17.11.17 For UKRS Ltd Contents 1. Roller Shutter Safety Standards 1.1 UK / Europe 1.2 USA 2. Fire Shutter / Curtain Standards 2.1

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

AGUSTA S.P.A. Amendment Docket No. FAA ; Directorate Identifier 2007-SW-33-AD

AGUSTA S.P.A. Amendment Docket No. FAA ; Directorate Identifier 2007-SW-33-AD Page 1 2009-15-14 AGUSTA S.P.A. Amendment 39-15977 Docket No. FAA-2009-0168; Directorate Identifier 2007-SW-33-AD PREAMBLE (a) This airworthiness directive (AD) becomes effective on September 9, 2009.

More information

Proposal Level May 3, Members, State Board of Education. Kimberley Harrington Acting Commissioner N.J.A.C. 6A: REASON

Proposal Level May 3, Members, State Board of Education. Kimberley Harrington Acting Commissioner N.J.A.C. 6A: REASON Proposal Level May 3, 2017 TO: FROM: SUBJECT: REASON FOR ACTION: AUTHORITY: Members, State Board of Education Kimberley Harrington Acting Commissioner N.J.A.C. 6A:27-7.13 Notice of proposed substantive

More information

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule NEW YORK CITY FIRE DEPARTMENT Notice of Public Hearing and Opportunity to Comment on Proposed Rule What are we proposing? The Fire Department is proposing to amend Section 4601-01 of Title 3 of the Rules

More information

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN) 4 of 326 11/21/2013 1:03 PM First Revision No. 161-NFPA 72-2013 [ Section No. 3.3.11 ] 3.3.11 Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

More information

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System 1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering

More information

ISO INTERNATIONAL STANDARD. Graphical symbols Safety colours and safety signs Part 2: Design principles for product safety labels

ISO INTERNATIONAL STANDARD. Graphical symbols Safety colours and safety signs Part 2: Design principles for product safety labels INTERNATIONAL STANDARD ISO 3864-2 First edition 2004-10-15 Graphical symbols Safety colours and safety signs Part 2: Design principles for product safety labels Symboles graphiques Couleurs de sécurité

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC-S527-11 ULC-G5.2 June 1, 2012 CERTIFICATION BULLETIN 2012-04 Effective Date Announcement CAN/ULC-S527-11, 3 rd Edition of the Standard for Control Unit for Fire Alarm Systems To: Subscribers

More information

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC SECTION 08 35 13.23 ACCORDION FOLDING FIRE DOORS PART 1 GENERAL 1.01 SUMMARY OF WORK A. Division 0 and 1, as indexed, apply to this section. B. Furnish and install

More information

Standards Update Notice (SUN) Issued: February 2, 2017

Standards Update Notice (SUN) Issued: February 2, 2017 Standard Information Standard Number: UL 778 Standard Name: Motor-Operated Water Pumps Standard Edition and Issue Date: 6 th Edition Issued July 7, 2016 and revision November 14, 2016 Date of Previous

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 2017-08-031 AN ORDINANCE OF THE CITY OF LANCASTER, TEXAS, REPEALING THE NATIONAL ELECTRICAL CODE 2014 EDITION IN ITS ENTIRETY AND REPLACING IT WITH THE ADOPTION OF THE NATIONAL ELECTRICAL

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing 3M Novec 1230 waterless

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

[Docket No. FAA ; Directorate Identifier 2013-CE-026-AD; Amendment ; AD ]

[Docket No. FAA ; Directorate Identifier 2013-CE-026-AD; Amendment ; AD ] [Federal Register Volume 82, Number 61 (Friday, March 31, 2017)] [Rules and Regulations] [Pages 15988-15993] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc

More information

HONEYWELL, INC.

HONEYWELL, INC. Page 1 2010-07-02 HONEYWELL, INC. Amendment 39-16246 Docket No. FAA-2008-0556; Directorate Identifier 2007-NM-028-AD PREAMBLE Effective Date (a) This AD becomes effective May 3, 2010. Affected ADs (b)

More information

CONTENTS AUTOMATIC TRANSFER SWITCHES

CONTENTS AUTOMATIC TRANSFER SWITCHES CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training

More information

Please think twice about printing this matrix. You can it, along with your ballot to or

Please think twice about printing this matrix. You can  it, along with your ballot to or Page Line Clause E/G Organization Comment (rationale) ii Foreword E GWM Recommend inserting the following text between the first and second paragraphs, Fire Alarm Systems shall be installed in accordance

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. 9/20/2016 2:27 PM Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical

More information

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number: DATE OF SUBMISSION TO: Department of Licenses and Inspections Commercial and Industrial Fire Inspection Unit 990 Spring Garden Street, 3 rd Floor, Philadelphia, PA 19123 AP# CITY OF PHILADELPHIA FIRE ALARM

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

Florida Senate SB 982 By Senator Bennett

Florida Senate SB 982 By Senator Bennett By Senator Bennett 1 A bill to be entitled 2 An act relating to electrical and alarm system 3 contracting; amending s. 489.503, F.S.; 4 requiring certain contractors to be certified 5 pursuant to part

More information

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter

More information

Standards Update Notice (SUN) Issued: January 9, 2017

Standards Update Notice (SUN) Issued: January 9, 2017 Standard Information This SUN contains new/revised requirements from updates dated September 2, 2016 and October 7, 2016 Standard Number: UL 1795 Standard Name: Hydromassage Bathtubs Standard Edition and

More information

Technical Committee on Electrical Equipment Evaluation. ROC Meeting Agenda September 28-29, 2010 Providence, RI

Technical Committee on Electrical Equipment Evaluation. ROC Meeting Agenda September 28-29, 2010 Providence, RI Technical Committee on Electrical Equipment Evaluation ROC Meeting Agenda September 28-29, 2010 Providence, RI Item 10-09-1 Call to Order Item 10-09-2 Introductions Item 10-09-3 Staff Remarks Item 10-09-4

More information

FAQs - Codes and Listings

FAQs - Codes and Listings The ADA EZ Wire Free Door Opener fully complies with the Uniform Federal Accessibility Standards (UFAS) Section 4.4 on Protruding Objects. For convenience and clarity the section of the standard appears

More information

ANSI/NETA Standards Update

ANSI/NETA Standards Update Specifications and Standards Activity ANSI/NETA Standards Update NOW AVAILABALE!!!! NETA Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems The NETA Acceptance Testing

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR SECTION 08 71 13 LOW ENERGY AUTOMATIC OPERATORS Specifier Note: Coordinate and edit articles

More information

UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923

UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923 P3 UNOFFICIAL COPY OF HOUSE BILL 1202 EMERGENCY BILL 5lr2923 By: Delegates McMillan, Boschert, Gilleland, and McDonough Introduced and read first time: February 11, 2005 Assigned to: Environmental Matters

More information

Electrical Tech Note 107

Electrical Tech Note 107 Electrical Tech Note 107 Biosystems & Agricultural Engineering Department Michigan State University Understanding the Construction Code Rules, Part 8 1 Based on the 2014 NEC and the 2015 MRC The State

More information

VERIFICATION OF FIRE ALARM SYSTEMS

VERIFICATION OF FIRE ALARM SYSTEMS DEVELOPMENT, BUILDINGS AND LICENSING Chief Building Official (CBO) and Building Code and Policy Building Policy Branch The intent of this bulletin is to clarify requirements of verification of the fire

More information

National Electrical Code

National Electrical Code National Electrical Code 409.30 Disconnecting Means Disconnecting means that supply motor loads shall comply with Part IX of Article 30. 410.81 Control (A) Disconnection Luminaires (fixtures) or lamp installation

More information

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS I. Introduction. This is the Motions Committee Report on Standards in the Fall 2013 Revision Cycle. The report identifies Certified

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

What You Need to Know About UL rd Edition

What You Need to Know About UL rd Edition What You Need to Know About UL 1598 3rd Edition Carl Bloomfield, Director of Business Services - Appliances & Lighting Introduction Prior to the first edition of UL 1598 in December 2000, there were multiple

More information

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION 1. GENERAL SPECIFICATION 1.1 The contractor shall provide an Intelligent AlarmLine Linear Heat Detection System to perform the following functionality: A. Fire Alarm, Supervisory and Trouble-Event Initiation

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

FIRE & LIFE SAFTEY STANDARD

FIRE & LIFE SAFTEY STANDARD Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications

More information

UNOFFICIAL COPY OF HOUSE BILL 1406 A BILL ENTITLED

UNOFFICIAL COPY OF HOUSE BILL 1406 A BILL ENTITLED UNOFFICIAL COPY OF HOUSE BILL 1406 M3 5lr2924 By: Delegates McMillan, Boschert, Gilleland, and McDonough Introduced and read first time: February 18, 2005 Assigned to: Rules and Executive Nominations 1

More information

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS June 20, 2011 TO: PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS SUBJECT: New Acceptance Criteria for Fixed Condensed Aerosol Fireextinguishing Systems, Subject AC432-0611-R1

More information

IRC - BUILDING - ELECTRICAL - ELECTRICAL TAC

IRC - BUILDING - ELECTRICAL - ELECTRICAL TAC IRC - BUILDING - ELECTRICAL - ELECTRICAL TAC W A R N I N G Copyright Notice: This document has been reproduced solely for considering proposed changes to the Florida Building Code with the permission of

More information

Report on First Revision November 2013 NFPA 731

Report on First Revision November 2013 NFPA 731 Report on First Revision November 2013 NFPA 731 731- Log #FR1 Final Action: (2.3.3) Submitter: Technical Committee Premises Security Recommendation: 2.3.3 UL Publications. Underwriters Laboratories Inc.,

More information

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362, This document is scheduled to be published in the Federal Register on 04/13/2012 and available online at http://federalregister.gov/a/2012-08917, and on FDsys.gov [7590-01-P] NUCLEAR REGULATORY COMMISSION

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM

DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM THIS COURSE IS FOR AGENTS WISHING TO DISABLE TRANSMITTING SIGNALS IN ORDER TO PERFORM MAINTENANCE TESTING AND DRILLS. OBJECTIVE The objective of

More information

SECTION GENERATOR PARALLELING CONTROLS

SECTION GENERATOR PARALLELING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 23 13 GENERATOR PARALLELING CONTROLS SPEC WRITER NOTE: Delete between // -- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law

1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law Page 1 1 of 1 DOCUMENT NEW JERSEY REGISTER Copyright 2009 by the New Jersey Office of Administrative Law VOLUME 41, ISSUE 9 ISSUE DATE: MAY 4, 2009 RULE PROPOSALS LAW AND PUBLIC SAFETY DIVISION OF CONSUMER

More information

SECTION INTRUSION DETECTION SYSTEM

SECTION INTRUSION DETECTION SYSTEM SECTION 13845 INTRUSION DETECTION SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested intrusion detection system, bearing Underwriters Laboratories (UL) mercantile listing

More information

FEDERAL REGISTER Vol. 73, No. 179 Rules and Regulations. DEPARTMENT OF LABOR (DOL) Mine Safety and Health Administration ( MSHA) 30 CFR Part 75

FEDERAL REGISTER Vol. 73, No. 179 Rules and Regulations. DEPARTMENT OF LABOR (DOL) Mine Safety and Health Administration ( MSHA) 30 CFR Part 75 FEDERAL REGISTER Vol. 73, No. 179 Rules and Regulations DEPARTMENT OF LABOR (DOL) Mine Safety and Health Administration ( MSHA) 30 CFR Part 75 RIN 1219-AB40 Fire Extinguishers in Underground Coal Mines

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards Wayne D. Moore, P.E., CFPS, SET Vice President JENSEN HUGHES 117 Metro Center Boulevard, Suite 1002

More information

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE Revision D January 14, 2005 DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE I. INTRODUCTION The Commission s requirements for fire protection of nuclear power plants allow licensees to voluntarily

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards

More information

Compatibility between Smoke Alarms and Arc-Fault Circuit Interrupters

Compatibility between Smoke Alarms and Arc-Fault Circuit Interrupters Page 2 A NEMA Low Voltage Distribution Equipment Section Document ABP 11-2016 Compatibility between Smoke Alarms and Arc-Fault Circuit Interrupters Published by National Electrical Manufacturers Association

More information

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE Health Chapter 420-5-22 ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE CHAPTER 420-5-22 SUBMISSION OF PLANS AND SPECIFICATIONS FOR HEALTH CARE FACILITIES TABLE OF

More information

Are You Prepared? The impending impact of Code on Servicing Security Systems

Are You Prepared? The impending impact of Code on Servicing Security Systems Sam Docknevich, PSP, Security Service Portfolio Manager Are You Prepared? The impending impact of Code on Servicing Security Systems Siemens AG 2015 All rights reserved. usa.siemens.com/infrastructure-cities

More information

Test Procedure for Clothes Dryers and Room Air Conditioners. NOPR Public Meeting

Test Procedure for Clothes Dryers and Room Air Conditioners. NOPR Public Meeting Test Procedure for Clothes Dryers and Room Air Conditioners Incorporation of Provisions for Addressing Energy Use in Standby and Off Modes NOPR Public Meeting Building Technologies Program Office of Energy

More information

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services www.intertek.com/lighting 1 Identifying Product Safety Requirements for Your Target Markets

More information

Electrical Safety Program.

Electrical Safety Program. University of North Carolina Wilmington Environmental Health & Safety Workplace Safety Electrical Safety Program GENERAL The UNCW Environmental Health & Safety Department (EH&S) is authorized by UNCW Policy

More information

UNOFFICIAL COPY OF SENATE BILL 464 A BILL ENTITLED

UNOFFICIAL COPY OF SENATE BILL 464 A BILL ENTITLED UNOFFICIAL COPY OF SENATE BILL 464 M3 5lr1662 CF 5lr1883 By: Senator Pinsky Introduced and read first time: February 4, 2005 Assigned to: Education, Health, and Environmental Affairs and Finance 1 AN ACT

More information

1.3 REFERENCE STANDARDS

1.3 REFERENCE STANDARDS SECTION 28 4600 FIRE DETECTION AND ALARM PART 1 -GENERAL 1.1 SECTION INCLUDES A. Fire alarm system design and installation, including all components, wiring, and conduit. B. Circuits from protected premises

More information

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety Div B 3.2.1.1.(4), (5) & (6) Exceptions in Determining Building Height BCBC1998-3.2.1.1.(4), (5) & (7) replace (harmonize with NBC) - NBC 2005 has significant revisions to provisions for mezzanines. These

More information

DENVER AMENDMENT PROPOSAL 2015 INTERNATIONAL CODES

DENVER AMENDMENT PROPOSAL 2015 INTERNATIONAL CODES DENVER AMENDMENT PROPOSAL 2015 INTERNATIONAL CODES NOTE: Each proposed Denver amendment to the International Codes must be justified. In order to be considered, the amendment proposal must address climate,

More information

DIMENSIONAL STANDARD FOR M22 THREAD CONNECT COUPLER RECEPTACLES AND PLUG COLLARS FOR PORTABLE PRESSURE WASHERS

DIMENSIONAL STANDARD FOR M22 THREAD CONNECT COUPLER RECEPTACLES AND PLUG COLLARS FOR PORTABLE PRESSURE WASHERS PWMA PW203-2014 PWMA Standard DIMENSIONAL STANDARD FOR M22 THREAD CONNECT COUPLER RECEPTACLES AND PLUG COLLARS FOR PORTABLE PRESSURE WASHERS Pressure Washer Manufacturers Association Sponsor: 1300 Sumner

More information

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) M E M O R A N D U M TO: FROM: NFPA Technical Committee on Alternative Approaches to Life Safety Linda MacKay DATE: December 28, 2010 SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) The ROP letter

More information

Emergency response lock box unit contents and maintenance.

Emergency response lock box unit contents and maintenance. 3750-75-04 Emergency response lock box unit contents and maintenance. [Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules,

More information

DIMENSIONAL STANDARD FOR 1/4" QUICK CONNECT COUPLER PLUGS AND SOCKETS FOR PORTABLE PRESSURE WASHERS

DIMENSIONAL STANDARD FOR 1/4 QUICK CONNECT COUPLER PLUGS AND SOCKETS FOR PORTABLE PRESSURE WASHERS PWMA PW201-2014 PWMA Standard DIMENSIONAL STANDARD FOR 1/4" QUICK CONNECT COUPLER PLUGS AND SOCKETS FOR PORTABLE PRESSURE WASHERS Pressure Washer Manufacturers Association Sponsor: 1300 Sumner Avenue Cleveland,

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARD INFORMATION Standard Number: UL 1082 Standard Name: Standard for Household Electronic Coffee Makers and Brewing-Type Appliances Standard Edition

More information

TOM BURNS, PLANNING DIRECTOR

TOM BURNS, PLANNING DIRECTOR ~~ 0 173 COUNTY OF SANTA CRUZ August 4,2005 PLANNING DEPARTMENT 701 OCEAN STREET, qth FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 TOM BURNS, PLANNING DIRECTOR Agenda:

More information

Baseline Data Required for AS

Baseline Data Required for AS Baseline Data Required for AS 1851-2012 Name: Brett Dundules Position: Technical Officer Organisation Fire Protection Association Australia Introduction Brief History of AS 1851-2012 Introduction of Baseline

More information

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests INTERNATIONAL STANDARD ISO 3999 Second edition 2004-12-15 Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests Radioprotection Appareils pour

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING SEMINAR 301 Part 1: Changes in the 2005 NEC SEMINAR RULES: There are no Rules All Questions need to be asked Stop at any time for an explanation SEMINAR PARTS: ELECTRIC and NEON SIGN STANDARDS By Randy

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The

More information

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES Established 1949 FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES The following are guidelines for new development. Any submitted plans must comply with these guidelines,

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 28, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 28, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: March 28, 2018 STANDARD INFORMATION Standard Number: ANSI Z245.21 Standard Name: Stationary Compactors Safety Requirements for Manufacturing and Reconstruction Standard

More information

SECTION SECURITY TESTING AND COMMISSIONING

SECTION SECURITY TESTING AND COMMISSIONING SECTION 280800 - SECURITY TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 WORK INCLUDES A. General Description: This specification section covers the provision of preliminary testing, acceptance testing,

More information

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information