JEREMIAS GROUP. CE MARK according to EN / 2.
|
|
- Shanon Hunt
- 6 years ago
- Views:
Transcription
1 JEREMIAS GROUP CE MARK according to EN / 2
2 CE MARK according to EN / 2 WHAT DOES THE CE MARK MEAN FOR STAINLESS STEEL CHIMNEY SYSTEMS? The CE MARK is the symbol obligatory since April 2005 that certifies that a stainless steel chimney is in accordance with the EN This standard specifies the performance requirements for rigid single and multi-wall system chimney products with metallic liners (chimney sections, chimneys fittings and terminals, including supports) used to convey the products of combustion from appliances to the outside atmosphere. It also specifies the requirements for marking, manufacturer s instructions, product information and evaluation of conformity of the product to the standard. The EN does not apply to self-standing chimneys Page: 2
3 CE MARK according to EN / 2 WHAT DOES THE CE MARK MEAN FOR STAINLESS STEEL CHIMNEY SYSTEMS? The manufacturer is obliged to realize the complete initial test of the chimney in a laboratory, and moreover, a Certified Body will: 1. -annually check that the manufactured product has the same quality as the tested one 2. -perform the quality control of the production process to ensure that it will satisfy the CE requirements, specified in the FPC (Factory Production Control). The CE MARK of the stainless steel chimney can only be granted by a Certified Body. The CE Mark enables the product to circulate freely in the European market, but each country could have its own installation rules Page: 3
4 CE MARK according to EN / 2 CE MARK LABEL 1. Standard 2. Temperature Level 3. Pressure Level 4. Condensate resistance 5. Corrosion resistance 6. Flue liner material specification 7. Soot fire resistance (O: no; G:yes) Page: 4
5 CE MARK according to EN / 2 CE MARK LABEL 1- Standard EN for vertical chimneys EN for connecting pipes 2- Temperature Level Maximum working temperature. The temperature used in the test and the resulting temperature levels achieved are as follows: As guidance, the temperature ratings applicable are: T200: all gas and oil applications (including condensing) T450: solid fuels and multifuels T600: power generators and CHP s Page: 5
6 CE MARK according to EN / 2 CE MARK LABEL 3- Pressure Level Admitted overpressure inside the flue, with its corresponding leakage rate As guidance, the pressure ratings applicable are: N1: natural draught installations P1: forced draught boiler installations H1: power generators, CHP s and micro CHP s Page: 6
7 CE MARK according to EN / 2 CE MARK LABEL 4- Condensate resistance Suitability of the flue for wet or dry conditions. D: the flue is suitable only for dry conditions. It does not resist condensate. W: the flue is suitable whether for dry and wet conditions. It resists condensate water inside. 5- Corrosion resistance Level of corrosion resistance due to the products of combustion of the different kinds of combustibles and different working conditions (dry or wet) V1: Tested and approved as resistant to attack from products of combustion from gas. V2: Tested and approved as resistant to attack from products of combustion from light oil (sulphur content <0,2%) and natural wood in dry conditions, and from gas in wet conditions (condensing appliances) V3: Tested and approved as resistant to attack from products of combustion from heavy oil (sulphur content >0,2%), solid fuels and peat in dry conditions Vm: Not tested. The manufacturer certifies only the material used in the inner wall by the quality certificate of the steel. For flues with this class there are specific regulations in each country indicating what material is suitable for each installation. As general guidance the stainless steel AISI 304 is equivalent to class V1, and the stainless steel AISI 316L is equivalent to classes V2 and V Page: 7
8 CE MARK according to EN / 2 CE MARK LABEL 6- Flue liner material specification The material of the inner liner must be specified and its minimum thickness as well: After that the minimum thickness of this inner liner is specified as follows: 040: 0,4mm 050: 0,5mm 060: 0,6mm Page: 8
9 CE MARK according to EN / 2 CE MARK LABEL 7- Soot fire resistance (O: no; G: yes) Soot fire resistance and minimum distance to combustible material It is expressed as G if the flue System has been tested, and as O if not. This classification is followed by the minimum distance (in mm) to combustible material. The test is a thermal shock of 1.000ºC during 30 minutes during which the System must endure and the temperature of combustible materials placed at the declared distance must not exceed 100ºC at an ambient temperature of 20ºC. The systems with O classification have not passed this test, so they cannot be used for any installation where the products of combustion contain soots (solid fuels, multifuels...). For low temperature applications, for instance room sealed boilers, where joints are used Page: 9
10 CE MARK according to EN / 2 CE MARK LABEL 8- Other declared characteristics: The characteristics of the previous points must be indicated in all documents of CE marking Hereinafter is a list of other characteristics that only appear in the DoP. (Declaration of Performance) Compressive strength (height for installation) Flow resistance of chimney sections fittings and terminals Minimum thermal resistance Flexural tensile strength Maximum distances between supports in non vertical installation Wind load resistance (maximum distances between fixing points and freestanding above the last one) Freeze thaw resistance Page: 10
11 Jeremias Group Quality JEREMIAS GROUP QUALITY COMPROMISE Jeremias is one of the world`s leading manufacturers of flue and chimney systems for the exhaust of gases and ventilation, covering all kind of domestic, commercial and industrial applications. Jeremias product range include 60 different CE certified systems covering commercial and domestic applications complemented by freestanding Industrial steel chimneys up to 3 meter diameter. Besides this compulsory CE Certification, Jeremias has also special certifications and listings needed in specific countries under i.e.; BS, Hetas, Swiss, Russian or US standards. For further information, Jeremias can supply technical guidance on various standards including the latest version of the European Standard /2:2010. Please contact our certification department Page: 11
12 Jeremias Group APPROVALS & CERTIFICATIONS Page: 12
13 System overview DOUBLE WALL SYSTEMS DW AL DW KL DW-KL DW VISION DW MAMMUT Page: 13
14 System overview SINGLE WALL SYSTEMS EW-FU EW-ECO EW-ALBI EW-Line FLEX EW-LAS Page: 14
15 System overview SINGLE WALL SYSTEMS EW-KL SV-EI-30 EW-VH EW-PPS EW-PPS-FLEX Page: 15
16 System overview PLASTIC & CONCENTRIC & DOUBLE WALL SYSTEMS CASCADE TWIN-PL TWIN-P DW ECO2.0 DW FU Page: 16
17 System overview SHAFTS & WALL-, FLOOR- AND ROOF SLEEVES FUMOLUX A/F FUMOLUX-P FURADO LUX FIX/VARIO LUX ECO Page: 17
18 System overview SHARE COLLECTIVE CHIMNEY & VENTILATION SYSTEMS SED SEE SET CLV SVC Page: 18
19 System overview STOVE PIPE & ACCESSORIES, VALVES, DAMPERS, SILENCERS FERROLUX AIR SUPPLY SYSTEM PELLET PIPE ACCESSORIES SILENCERS Page: 19
20 Jeremias Group INTERNATIONAL PROJECTS
Technical Guidance CE Marking of Metal Chimneys and Flues
CE Marking of Metal Chimneys and Flues Steel Chimney Programme Schiedel is the leading producer of ceramic chimney systems in Europe, and are now regarded as the market leaders in prefabricated stainless
More informationTWIN - GAS. Concentric flue gas system for decorative gas fires.
TWIN - GAS Concentric flue gas system for decorative gas fires www.jeremias-group.com TWIN - GAS 2 TABLE OF CONTENTS Concentric balanced flue system TWIN - GAS Jeremias - your reliable partner System overview
More informationEXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.
www.jeremiasinc.com GENERAL INFORMATION COMMERCIAL CHIMNEY LINING If an existing chimney is showing signs of wear and tear due to its age or no longer fulfills the requirements of a modern heating system,
More informationPUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD CPD 0081
LINE 60 LINE 80 LINE 100 ALUMINIUM SINGLE WALL MANUAL FOR INSTALLATION, USE AND MAINTENANCE 06 0051 0051 CPD 0080 0051 CPD 0081 MI-MP_en_1.1.odt 1/8 WARNINGS Installation must be done by qualified personnel
More informationPUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD 0080
INSULATED LINE 80-100 INSULATED LINE 100-125 INSULATED ALUMINIUM TWIN WALL MANUAL FOR INSTALLATION, USE AND MAINTENANCE 06 0051 0051 CPD 0080 MI-DP_en_1.1.odt 1/8 WARNINGS Installation must be done by
More informationImplementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -
TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationCHIMNEYS AND VENTS CHAPTER 8
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationTW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40
TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a
More informationImportance of a Draught Regulator
Importance of a Draught Regulator The purpose of a chimney (stack) is to generate a draught (draft) that will transport smoke and fumes away from the point of combustion. The chimney design and arrangement
More informationEligibility criteria
Accelerated Capital Allowances Eligibility Criteria Ref. No.: HWG 3.3 Category: Heating and Electricity Provision Technology: Boilers and Water Heaters Boilers and Water Heaters are defined as advanced
More informationPart J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher
Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher 1 The Building Regulations The England & Wales Building Regulations are legal requirements that
More informationFireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT
FireFlexmaster A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT FireFlexmaster Flexible Chimney Liner Introduction A twin skin
More informationPellet Vent INSTALLATION INSTRUCTIONS
Pellet Vent INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS PELLET
More informationEsse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL
Esse 700 27B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse Stoves & Cookers Long Ing. Barnoldswick, Lancashire BB18 6BN. United Kingdom. Tel: + 44 (0) 1282 813235 F: + 44 (0) 1282 816876 enquiries@esse.com
More informationINSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT
C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS
More informationFurenflex RWV Advanced Liner
Furenflex RWV Advanced Liner To BS EN 1443:2003 Report 55942/1 Carried out for Kompozitor Ltd. By Dave Butler 08 June 2012 Furenflex RWV Advanced Liner To BS EN 1443:2003 Carried out for: Kompozitor Ltd.
More informationTwin Wall Installation Instructions And Maintenance Guide
Twin Wall Installation Instructions And Maintenance Guide Please read all instructions before beginning your installation. Failure to install this system in accordance with these instructions will invalidate
More informationbest practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to
best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to BS EN 16034: 2014 Permission to reproduce extracts from BS EN 16034 : 2014 is granted by BSI. DHF BEST PRACTICE
More informationAssessment Schedule - TS.6
The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall
More informationIrish Standard I.S. EN :2009
Irish Standard NSAI 2009 No copying without NSAI permission except as permitted by copyright law. Incorporating amendments/corrigenda issued since publication: This document is based on: This document
More informationGeneral Guidance on the selection and installation of flues and chimneys for wood burning and multi fuel appliances in residential properties.
UPDATED TO INCLUDE CHANGES IN THE NEW VERSION OF BS EN 15287-1 February 2014 General Guidance on the selection and installation of flues and chimneys for wood burning and multi fuel appliances in residential
More informationAnnex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)
Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic) Routes to demonstrating required competence Inspection
More informationCOMPANY PROFILE.
COMPANY PROFILE www.jeremias-group.com JEREMIAS GROUP 8 Production sites 83,000 References worldwide 1,200 Employees 60 Countries 2 A STRONG, OPEN AND INTERNATIONAL GROUP WELCOME TO JEREMIAS GROUP Jeremias
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 / 15-02-2008 The company E. is outstanding in the field of central heating
More informationAUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS
AUTOMATIC MAKE-UP AIR DAMPER WITH READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Installation
More informationSFA Guide to Building Regulations and Solid Fuel Heating
SFA Guide to Building Regulations and Solid Fuel Heating Solid Fuel Association 95 High Street Clay Cross Chesterfield Derbyshire S45 9DZ 01773 835400 www.solidfuel.co.uk Building Regulations and Solid
More informationMicrogeneration Certification Scheme: MCS 008
Microgeneration Certification Scheme: MCS 008 Product Certification Scheme Requirements: Biomass Issue 2.2 This Microgeneration Product Certification Standard is the property of Department of Energy and
More informationForced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016
Forced Draft Boiler Flue Gas Venting: Problems & Solutions Presented by Steve Connor and Patrice Gouin January 27, 2016 What Will We Be Covering Today? Pressurized Non-condensing Vent Systems Venting s
More informationDomestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers
Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers Issue 1 September 2013 Public Version REFERENCE: QUERIES TO: CER/13/273 Paul Tierney (ptierney@cer.ie)
More informationFlues and chimney systems
Flues and chimney systems Complete systems overview Table of content About us 02 Portfolio overview 03 Timeline 04 Gas flue systems 06 Chimney systems rigid single-wall 08 Chimney systems flexible single-wall
More informationINSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20
INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8
More informationCommissioning of Heat Producing Appliances Burning Solid Fuel
Building Control Technical Guidance Leaflet No. 15 This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum Commissioning of Heat Producing Appliances Burning Solid
More informationBoiler Technical Specifications (2013)
ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855)
More informationAIEA Presentation. Wood pellets heating systems.
AIEA Presentation Wood pellets heating systems Introduction to the AIEA 16 Local Energy Agencies in Ireland, including 3 in Northern Ireland. Association of Irish Energy Agencies (AIEA) formed in November
More informationSingle Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054
MC-CG-105 EN_892054 WARNING Installation Manual CoxDENS PPs Incorrect installation of Flue System and Components, or failure to follow installation instructions, can result in property damage or serious
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationSolid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance
Solid fuel hot water boiler TKH 250-400 KW INSTRUCTIONS MANUAL for usage and maintenance Prhovacka bb 22310 Simanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 oce@termomont.rs www.termomont.rs April
More informationPLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion
AUTOMATIC MAKE-UP AIR DAMPER WITH To register this product visit: www.broan.com MODELS MD6T MD8T MD10T READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE,
More informationInstallation & Manual. Model T-25
Installation & Manual TR Central Heating Stove With Solid Fuel Model T-25 Tested according to DIN EN 13240 For product efficiency and emission values, see the declaration of conformity! TABLE OF CONTENTS
More informationRiva Studio Dedicated Sealed External Air Kit
Riva Studio Dedicated Sealed External Air Kit For Studio Duplex Instructions for Use, Installation & Servicing For use in GB & IE (Great Britain & Republic of Ireland). IMPORTANT Please read these instructions
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationPermanent Ventilators (for the Supply of Combustion Air)
(for the Supply of Combustion Air Essentials (for Supply of Combustion Air All heating appliances that produce heat from the combustion of carbon based fuels such as gas, oil and solid fuels including
More informationDirect Vent System Required
CB-200A Cottage Base Installation Instructions IMPORTANT: Read all instructions carefully before beginning the installation. This base must be installed by a qualified installing agency and in accordance
More informationSTATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE
STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE Name of Appliance Name and Address of manufacturer Type of appliance eg 'freestanding roomheater' Minimum distance to combustibles Minimum distance from combustibles
More informationEvaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances
1st February 2011 regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances Foreword This has been adopted by the Kiwa Board of Experts of Energy
More informationCE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.
CE arking for Fire Resistant doors. The future EN 16034 Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab. AFITI-LICOF 1 Overview Pedestrian doorsets, industrial, commercial, garage doors
More informationRemeha. Fuel oil/gas boilers P 520. Installation and Service Manual A
Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It
More informationanti-condensation valve
anti-condensation valve Dimensions B C B Function The ltecnic anti-condensation valve connects between a biomass burning boiler and a direct or indirect heating system or domestic hot water system. It
More informationINSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH
INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH TABLE OF CONTENTS General Safety Information Page 2 Chimney and Flue Information Page 3 Installing the Appliance Page 4 Flue Draught Page 5 Chimney
More informationThe stove pictured on the cover is the Evo 30 (see page 9)
h a r n e s s t h e p o w e r o f w o o d The stove pictured on the cover is the Evo 30 (see page 9) www.woodfirestoves.co.uk Woodfire Technical range Contents The Woodfire Technical range......................................
More informationnatural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm
natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN 330-5 norm Biomass - the curse of energetics or the only fuel of the future? The real
More informationRS Chimney Fan for Solid Fuel Applications
Installation & Operating Manual RS Chimney Fan for Solid Fuel Applications USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up
More informationWhy our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled
Why our flame is so natural... Our range of balanced flue gas stoves gives a beautiful lazy dancing flame pattern which emulates that of a traditional wood burning stove and with the added features of
More informationUSER MANUAL 9kW LILLY PELLET STOVE
USER MANUAL 9kW LILLY PELLET STOVE Table of Contents.Overview of Stove Parts... 2.Technical Characteristics... 3 3.Important Information... 4 4.Pellet Specification...5 5.Technology... 6 6.Installation...
More informationMaintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE
29-10-2013 CAUTION Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE Service the stove COMPLETELY as described in this manual. Check the chimney pipe. BLOCKED FLUE MESSAGE
More informationAccording to the following European Regulations which come into force:
WHAT HAPPENS? From September 26th 2015, in order to be placed on the European market, all products and systems used for heating, production and storage of hot water must comply with the MINIMUM ENERGY
More informationThe intelligent alternative for flue gas venting systems
The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason
More informationRS Chimney Fan for Solid Fuel Applications
Installation & Operating Manual RS Chimney Fan for Solid Fuel Applications USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start
More informationPVE SERIES POWER VENTER SYSTEM MANUAL
PVE SERIES POWER VENTER SYSTEM MANUAL Contents Page I. Typical Venting System Components 2 II. System Operation 3 III. Power Venter Sizing 3,4 IV. Installation Safety Instructions 5,6 V. Installation of
More informationPOWER VENTER. Model: PVE Series
POWER VENTER Model: PVE Series CONTENTS Typical Venting System Components... System Operation... Power Venter Sizing... Installation Safety Instructions... Installation of Power Venter... Connecting Power
More informationTONAdin triple-wall insulated chimney of round design. TONAtec plus air/flue chimney for all fuel types (specifically biogenic solid fuels)
TONA Ceramic Chimney Systems for Europe IC M A E R E E T C N A R A GU TONA The specialist for ceramic chimney systems in Europe TONA began its ceramics production in 1891 and today is one of the leading
More informationINSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM
INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM Thank you for choosing a DOMUSA TEKNIK heating boiler. Within the product range offered by DOMUSA TEKNIK you have chosen BioClass HM model. With a suitable
More informationVPC Gas Cabinet Heater Range
VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS VPC Overview Models Available VPC UF - Upright Freeblowing
More information2012 INTERNATIONAL FUEL GAS CODE VENTS
2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationBevent Rasch. FIDs. - Fire /05/18
Bevent Rasch - - FIDs /0/8 Self-acting back draught damper for combustion gases, without commissioning function Sizes Ø 80 to 60 mm For mounting on manifold distribution box BRSL www.bevent-rasch.com Product
More informationINSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationFlue & Chimney Systems
Flue & Chimney Systems BS EN ISO 9002:1994 Certificate No. FM 34121 HAMWORTHY flue products System Solutions Prefabricated Stainless Steel Flues & Chimneys With a multitude of flue systems and components
More informationEXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE
THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the
More informationThe stove pictured on the cover is the Evo 30 (see page 7)
21 s t c e n t u r y h e a t i n g The stove pictured on the cover is the Evo 30 (see page 7) Printed using vegetable inks on FSC certified paper. Please recycle after use. www.woodfirestoves.co.uk Woodfire
More informationBy Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference
By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation
More informationSo old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.
ARREDO E BENESSERE So old fashioned... An intelligent choice When on a cold winters night the warm glowing flames of the KALDUS boiler are there to welcome you back home, you will be pleased that you decided
More informationPOWER VENTER SYSTEM. Model: PVO-300, PVO-600
POWER VENTER SYSTEM Model: PVO-300, PVO-600 Included is one ETL and cetl listed Power Venter to be used primarily with a single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO may
More informationCommercial Flue Guide
Commercial Flue Guide Published by the British Flue and Chimney Manufacturers Association. 2 Waltham Court, Milley Lane, Hare Hatch, Berks, RG10 9TH. Tel: 0118 940 3416 Fax: 0118 940 6258 Email: info@feta.co.uk
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationGuidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC
CEN/TC 88 N 2873 GNB-CPD SG19 Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC NB-CPD/SG19/11/085 Issued: 19 October 2011 APPROVED - GUIDANCE GNB-CPD position
More informationSkorstenar Utförandestandard för metallskorstenar
SVENSK STANDARD SS-EN 12391-1:2004 Fastställd 2004-07-16 Utgåva 1 Skorstenar Utförandestandard för metallskorstenar Del 1: Skorstenar för ej rumsförslutna eldstäder Chimneys Execution standard for metal
More informationWOLVERTON STOVES U S E R M A N U A L S h A N d o N / A R d L E i g h
WOLVERTON STOVES U S E R M A N U A L S h a n d o n / A r d l e i g h C O N T E N T S This User Manual applies to Shandon & Ardleigh stoves SECTION ONE: I. Technical Data...4 II. Technical Description...4
More informationWindow and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation
Window and Door Standards for Performance and Security Russell Day Senior Technical Officer Glass and Glazing Federation The Standards BS EN 14351-1:2006+A2:2016 Windows and doors. Product standard, performance
More informationPowerVent. Installation manual (GB) English. Store this document in a safe place UK
PowerVent Installation manual (GB) Store this document in a safe place 959.034.03.UK GB Contents Blz Foreword 3 1. Introduction 3 2. CE declaration 4 3. SAFETY 4 3.1 General 4 3.2 Regulations 4 3.3 Precautions
More informationAdvanced Venting Systems
Advanced Venting Systems 1 Z-Vent Special Gas Vent 3 Flexible Vent Connector Systems 5 Aluminium Chimney Liner System 7 Stainless Steel Chimney Liner System 9 Oval Liner System / Advancing the Industry
More informationRiva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT
Riva F40 Cube Multi-Fuel Free Standing Stove Installation Instructions Models: RVF40C For use in Great Britain and Eire This product is suitable for use in the stated countries. To install the product
More informationRead and Save These Instructions All Hoods Must Be Installed By A Qualified Installer
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING
More informationCP+ Gas & Oil Cabinet Heater Range
CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed
More informationWELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS
GAS 110 ECO WHAT S INSIDE 03 WELCOME TO REMEHA 03 INTRODUCING THE REMEHA GAS 110 ECO RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 11 DIMENSIONS
More informationMODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.
MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) Q 1. a) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel. 2) steam turbine- It is a device that extract
More informationIntroduction. General. Other regulations. British Standards and European Technical Specifications
Introduction General This Technical Booklet has been prepared by the Department of Finance and Personnel and provides for certain methods and standards of building which, if followed, will satisfy the
More informationOPERATING INSTRUCTIONS with safety features
Solid fuel boiler TKK3 with wood pellet burner TERMEC 70-90 KW OPERATING INSTRUCTIONS with safety features Prhova ka bb 22310 imanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 oce@termomont.rs www.termomont.rs
More informationAIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube
LABORATORY MANUAL ON STUDY OF FIRE TUBE AND WATER TUBE BOILERS Prepared By Prof. (Dr.) M. K. Roul Professor and Principal, Gandhi Institute for Technological Advancement (GITA), Bhubaneswar 752054 June
More informationUltraOil Condensing Oil Boiler
UltraOil Condensing Oil Boiler Responsibility for energy and environment Output range 35 to 600 kw Why choose UltraOil? The UltraOil condensing boiler featuring our patented alufer heat exchanger and two-stage
More informationRocket heater GAMERA
Rocket heater GAMERA High efficiency heater on hard fuel Manufacturer: AGNON Ltd., Bulgaria Hissarya, 4 Han Kubrat STR. +359 885 525 464 WWW.GAMERA.EU ROCKETGAMERA@GMAIL.COM ATTENTION! Read the following
More informationWebsite:
Operating & Installation Instructions Firebelly Production Facility: Unit 16 Upper Mills, Canalside Slaithwaite Huddersfield West Yorkshire U.K. HD7 5HA Firebelly Sales Office and Showroom: Units 6 & 7
More informationInspection Checklist Mechanical Rough in
Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and
More informationFlues and chimney systems
Flues and chimney systems Complete systems overview CLV systems concentric Description 4 4 1 3 The concentric CLV system is a collective chimney system especially for apartment buildings. It brings combustion
More informationDNVGL-CP-0407 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0407 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationBuilding Constructions 4
Building Constructions 4 Chimneys combustion exhaust gas ventilation systems assembled by : dr. Ottó Czeglédi, Gyula Dési Chimneys combustion exhaust gas ventilation systems (flue gas stacks) - Chimney
More informationVPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning
VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed
More informationFire dampers. For diverse applications
. X X testregistrierung Fire dampers Type with fusible link for 72 C or 95 C CE compliant according to European regulations With TROXNETCOM as an option ATEX certification For diverse applications Rectangular