1 Where technical minds provide innovative solutions From Utility Company (ConEd, PSE&G, etc) Service End Box CT Cabinet Custom Crown/ Pull Boxes Internal Construction (Example) Service Entrance Distribution Section Service Section Internal Construction (Example) PanelBoards (Meter Bank) Multi-Family Metering Pull Thru Wireway (Trough) Powder coated. Also available in Type 304 or 316 Stainless Steel Downstream Equipment Please visit our Pull Box and Enclosures section
2 Panelboards are available in different sizes(p1-p5), power ratings (Amp), internal construction. Here we use Lighting Panel (P1) as an example The interior includes overcurrent protection devices (breakers), bus bars and insulated neutral bus bars. A lighting panel interior is mounted inside the can (back box) using 4 mounting studs. Residential circuit breakers are typically1-pole, 2-pole, or 4-pole breakers with current ratings of 225 amps or less and voltage ratings of 120 volts, 120/240 volts, or 240 volts
3 SWITCHBOARD There are multiple elements that make up a switchboard. Included in the list of elements are a frame, buses, overcurrent protection devices(breakers, Switches), service metering, and outer covers. Bus (busbar) Phase Arrangement Bus bars (made out of copper) are required to have phases in sequence so an installer will find the same fixedphase arrangement in each termination point in any switchboard. This requirement is established by NEMA (National Electrical Manufacturers Association). Disconnect switches CT Cabinet Pull Box Several options are available to bring power into the switchboard service section, cable, pull box and bus duct. We will look at each one individually. Cable and Conduit Pull Box Added Bus Duct Entrance
4 Busway Advantage In electrical power distribution, a bus duct (also called busway), is a sheet metal duct containing either copper or aluminum busbars for the purpose of conducting a substantial current of electricity. The three main ways that a busway system will save you up front money over conduit and cable are: 1) Material Costs, 2)Shipping Costs, 3)Labor Costs Busway is defined by the National Electrical Manufacturers Association (NEMA) as:...a prefabricated electrical distribution system consisting of bus bars in a protective enclosure, including straight lengths, fittings, devices, and accessories. Busway includes bus bars, an insulating and/or support material, and a sheet metal housing. Elbows enable turns and height changes in the busway system. An elbow can turn the busway system right or left, up or down. Elbows are supplied with a joint stack and covers. Elbows may be ordered as stacks or sections. Elbow stacks are joint stacks that are angled "edgewise" (for up/down changes) or "flatwise" (for left/right changes).
5 Metering System An insulating block secures the lugs, jaws, and bussing to the enclosure. Current Path When in operation, electrical current flows from the service (line-side) conductors through the meter to the load-side conductors and then to the load center or panelboard for distribution to branch loads Each watt-hour meter requires a meter socket to safely and securely connect it to the electrical service. Because meter designs and utility requirements vary, Apelio offers a variety of singleposition and multiple-position meter sockets.
6 TROUGH Wireway Trough is designed to protect wiring against rain, sleet and snow in outdoor installations, or indoors against dripping water. Fabricated in accordance with UL specifications from gauge Galvanized Powder coated Steel, Aluminum or SS304/ SS316. Continuously welded body, gasketed rainproof Cover with heavy duty butt hinges and quick release clamps. Telescope Fitting Adjustable Telescopic Fitting makes it easy to adjust the length of final connection and save the hassle of precise measuring 90 Sweep Elbow and Sweep Tee designed for large radius turns. Used with vertical or horizontal Trough sections. Removable top and inside covers.
7 Pull Boxes/ Crown Boxes Apelio's ability to manufacture high end Pull Boxes is not limited to custom boxes. We carry a large array of standard Pull Boxes ranging from the smallest to the largest sizes, painted to withstand rust and made from quality materials. Custom dimensioning to customer specifications, our boxes are made with superior welding that helps prevent box deformation when pulling cables or punching multiple holes in them. Our Pull Boxes made of rigid body acuminated by superior welding and materials to withstand harsh environments. Apelio offers wide range of material thickness and type to satisfy every need. Bodies and doors fabricated from 16,14, or 12 gauge carbon steel and pre-galvanized or Galvannealed steel Removable Covers Sectional Dismantle Powder coating availability SwitchBoard Hole Lineup Complex Design with dividing capabilities will allow customer to use the same box in different applications
8 Pull Boxes, Enclosures APELIO offers a wide range of electrical enclosures ideal for a variety of indoor or outdoor applications. The National Electrical Manufacturer Association (NEMA) uses a standard rating system that defines the types of environments in which an electrical enclosure can be used, and frequently signifies a fixed enclosure's ability to withstand certain environmental conditions. We manufacture All NEMA rated enclosures. Per customer request most of them can be made our of either Powder coated Galvanized steel, Aluminum or Stainless Steel type 304 or 316. Here we explain a few the most popular NEMA types.. NEMA 4X enclosures are primarily intended for outdoor use and offer a superior level of protection from corrosion and extreme environments. APELIO produces these enclosures in 5052-H32 aluminum, 304 or 316 Stainless Steel and they are available in a number of styles for your demanding applications. Our adherence to the rigorous NEMA standards will give you a quality enclosure, delivered quickly at a competitive price. NEMA 12 enclosures are intended mainly for indoor industrial, manufacturing, and machining applications. These metal enclosures will protect against dust, dirt, and dripping non-corrosive liquids, oil and lubricants NEMA 3R enclosures are compatible for both indoor or outdoor applications, and holds the least demanding rating for outdoor use. Mostly made for lighting contractors, housing power distribution, switch gear, and other electrical components that need to be protected in an outdoor environment. APELIO produces NEMA 1 electrical enclosures for general purpose indoor use. We adhere to NEMA standards to provide you a quality enclosure for most basic applications. NEMA 1 enclosures are intended for use fundamental applications, or where extreme environmental conditions do not exist
SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA
PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low voltage power panelboards 1.02 RELATED SECTIONS 1.03 REFERENCES
More informationSECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.
SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance
More informationCOMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods
1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,
More informationASCO Series 185 Power Transfer Switches
ASCO Series 185 Power Transfer Switches 24-hour protection no matter when trouble strikes ASCO Series 185 POWER TRANSFER SWITCHES An Automatic Transfer Switch helps prevent... Your business or home from
More informationSECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES
PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,
More information1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.
September 2012, rev. 00 26 2416 Panelboards PART 1. GENERAL 1.01 Summary A. Section includes: 1.02 Definitions 1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load
More informationCustom Duct Heaters. Special Applications
Special Applications Air Conditioning & Air Handling Units For more than 55 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 49). A wide
More informationCustom Duct Heaters. Special Applications
Special Applications Air Conditioning & Air Handling Units For more than 50 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 50). A wide
More informationSECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationA. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.
SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:
More informationCHAPTER 20 SERVICE EQUIPMENT
SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control
More informationPART GENERAL 1.01 SECTION INCLUDES
Specification Number: 26 24 16.06 Product Name: Emergency Lighting Control NQ Circuit Panelboards: 240 Vac, 48 Vdc Maximum SECTION 26 24 16.06 Emergency Lighting Control NQ Circuit Panelboards: 240 Vac,
More informationStudent Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.
SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:
More informationPANELBOARDS & BUILDING DISTRIBUTION
262416 PANELBOARDS & BUILDING DISTRIBUTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Distribution panelboards 2. Power panelboards B. Related Sections: 1.02 POLICY 1. CU Standard 260500, Basic
More informationSECTION ISOLATED POWER SYSTEMS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationA. Shop Drawing submittals shall include, but not be limited to, the following:
SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)
SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill
More informationINSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM
INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................
More informationSpecial Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:
CONTROLLER CABINETS, POLE MOUNTED - Item No. Special Provision No. 682S27 June 2017 1. SCOPE This Special Provision covers the requirements for the installation of pole mounted controller cabinets and
More informationINSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY
INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5
More informationSECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.
SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.
More informationDay after day, Season after season, Generation after generation.
FARM Bins Superior bins prove their strength and ability to protect crops from the harshest elements Day after day, Season after season, Generation after generation. There s nothing standard about Superior.
More informationMN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET
MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET LIGHTING SERVICE CABINET TYPE: L1 & L2 02/02 /2012 Page 1 of 21 SPECIFICATIONS FOR L1 & L2 LIGHTING SERVICE CABINETS Table of Contents 1. General
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationASME Packaged Electric Water Heater
MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long
More informationCONTENTS AUTOMATIC TRANSFER SWITCHES
CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training
More informationCoil-In-Tank Design: Refrigeration System: Cabinet Construction:
Rite-Temp Manufacturing pioneered the development of refrigerated industrial water chillers in 1948. Since the first Rite-Temp units were introduced, quality engineering and manufacturing has been a key
More informationPowerWave 2 Busway System
PowerWave 2 Busway System Guide Specifications (Revision 004, 11/17/2017) 1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening,
More informationSUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE
SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE SUPPORT EQUIPMENT Deployable Rapid Assembly Shelter (DRASH) Support Equipment are shelter components that can be used to enhance
More informationINSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM
INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting
More informationExplosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1
Explosion Proof Light - 400 Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1 Part #: EPL-HB-400W-MH Made in the USA The EPL-HB-400W-MH metal halide, hazardous area light fixture from Larson Electronics
More informationTOOLS & MISCELLANEOUS
TOOLS & MISCELLANEOUS 01-5095 251189 Sillcock Tee Handle, For 16 Broach Splined Stem, Fits Most Outside Hose Valves. 052151010056 01-5223 251199 4 Way Stem Key, Fits Square Stems 1/4, 9/32, 5/16, & 11/32.
More informationINSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP
INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................
More informationuu3-1/2-inch-deep rigidized roof ribs are locked to the roof wind ring, so the roof acts as a single, dynamic unit.
COMMERCIAL Bins Roofing Start From The Top Roof Ribs Bin roofs need to withstand high winds and loads from snow and equipment. More than that, roof strength is crucial to maintaining the entire structure.
More informationPackaged Steam Fired Water Heater
MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction
More informationTABLE OF CONTENTS page 2
TABLE OF CONTENTS page 2 Metal Sheath Design... page 2 Mechanical Design...... page 3-7 Safety Protection...... page 7 Technical Design Data.....page 7 & 8 Temperature Control Guide...... page 8 Electrical
More informationSTATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES
STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES Articulation Agreement Identifier: ELT 118 (2005-1) Identifier is the postsecondary course prefix followed by Plan-of-Instruction
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationS U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE
S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: This ordinance is organized into eight Articles, as follows: Article I. Article II. Article III. Article
More informationThermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping
Maxiband Heaters The Most Sought After Band Heater A B Maxiband General purpose terminal box offers excellent protection to the exposed terminals. To simplify electrical wiring, the box has two 1/2" trade
More informationInstallation and Maintenance Manual Please retain this manual for future reference.
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. Electric Construction Heaters
More informationC. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.
SECTION 235100 - BREECHINGS, CHIMNEYS, AND STACKS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fabricated breechings. B. Manufactured chimneys for gas fired equipment. C. Manufactured double wall chimneys for
More informationINSTALLATION INSTRUCTIONS FOR MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationINSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS
More informationINSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS
RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM
SECTION 23 81 06 - PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. This Section includes equipment types that contain all the components of the refrigeration process within
More informationElectricity Unit Notes. Agriculture Mechanics I
Electricity Unit Notes Agriculture Mechanics I Principles of Electricity Electricity is a form of energy that can produce light, heat, magnetism, chemical changes Resistance: tendency of a material to
More informationPackaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase
Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free
More informationINSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS
More informationDRYER INSTALLATION INSTRUCTIONS
DRYER INSTALLATION INSTRUCTIONS Table of Contents DRYER SAFETY... 1 INSTALLATION REQUIREMENTS... 2 Tools and Parts... 2 Location Requirements... 3 Electrical Requirements... 5 INSTALLATION INSTRUCTIONS...
More informationMunicipal Code of Chicago TITLE 14E ELECTRICAL CODE
Municipal Code of Chicago TITLE 14E ELECTRICAL CODE Ch. 14E-1 General Ch. 14E-2 Wiring and Protection Ch. 14E-3 General Requirements for Wiring Methods and Materials Ch. 14E-4 Equipment for General Use
More informationPTAC 2017 Air Conditioner Collection
PTAC 2017 Air Conditioner Collection PTAC COLLECTION The Frigidaire 2017 PTAC Collection offers flexibility for any application. Simple, intuitive controls and options, including remote thermostats, allow
More informationMichigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013
Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013 1. Is a standard wire-nut approved for a wet location as in an outside j-box? Is there a listed
More informationInstallation Instructions
Installation Instructions Before you begin... 2 Location... 2 Recommended grounding instructions... 2 Electrical requirements... 2 Exhaust requirements... 3 Water supply and drain requirements... 3 Please
More informationTABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6
TABLE OF CONTENTS Page FCV Nomenclature 3 FCV Features & Construction 4 FCV Engineering Specifications 5 FCV Fan/Coil Data 6 FCV Unit Weights and Volumes 7 FCV Fan and Motor Data 8-9 Dimensions 10-14 Standard
More informationBy Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference
By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation
More informationPackaged Terminal Air Conditioner (PTAC)
Packaged Terminal Air Conditioner (PTAC) Air Conditioner / Heat Pump / Backup Electric Heater 16" 42" Depth 21-3/4" More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize
More informationCURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version
Project: Fixture Type: Location: Contact/Phone: CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version PRODUCT DESCRIPTION The Juno Trac-Master
More informationIDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems
SECTION 26 05 54 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Permanent Marking. 6. Underground
More informationINSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationCF1 ProVector Explosion-Proof Heaters
CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations
More informationOCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING
More informationInstallation Instructions
Installation Instructions Gas & Electric Dryer Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely.
More informationIMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016
IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS June 17th, 2016 RE: City Council Adopts 2014 National Electrical Code with Pool Alarm Requirements On April 25th, 2016 the
More informationSchneider Electric ibusway for Data Center: Schneider Electric Powerbus Plug-In Busway
Schneider Electric ibusway for Data Center: Schneider Electric Powerbus Plug-In Busway THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTERFORMAT.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 2416 - PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationB.C.S. Shop Heaters 26, 30 & 36 (36 shown)
BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass
More informationDryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41
Dryer User manual DV22K6800** DV22K6800-03650A-00_EN (US)_151211.indd 1 2015-12-11 7:15:41 Before installation Read through the following instructions before installing the dryer, and keep this manual
More informationHOLDING/PROOFING CABINETS HP2H-2M-SN APPLICATION OPTIONAL MODULAR CONSTRUCTION
HP1H-M-SN HP1V-M-SN HPH-M-SN HPV-M-SN HOLDING/PROOFING CABINETS APPLICATION To satisfy a need for high quality, shipboard grade, heated products, Cospolich has introduced their "HP" class of horizontal
More informationCADDY CORPORATION. Utility Distribution Systems
Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which
More informationThermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment
Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Platen Heaters are widely accepted as the industry standard for heating critical, temperaturesensitive plastics
More informationNATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY
A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -
More informationTempco s process controllers provide integrated solutions to manage your thermal loop system.
5 Control Panels Managing 5 Circulation Heating Systems Application: Cleaning and applying chromate coating to aircraft parts Tempco s process controllers provide integrated solutions to manage your thermal
More informationNITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM
NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This section outlines the requirements for the nitrogen-generating sprinkler corrosion inhibiting system. The work
More informationPortable Vertical Air-Conditioning and Heating Systems
Portable Vertical Air-Conditioning and Heating Systems Specifications for 10 Ton Units 208 230 volt 7 1 77 77 77 33 Front Side Back 77 71 / 77 Front 33 Side 2 Cabinet Features: Heating and Cooling Data:
More informationEB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508
Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional
More informationInstallation Instructions
Installation Instructions Full Size Laundry Center Gas & Electric Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the laundry center is
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)
More informationElectrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING
Electrical System After re-designing the lighting system for the children s computer, circulation and storytelling areas, the electrical system had to be redesigned as well. These are the new panel board
More informationSeries PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection
Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment
More informationKold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT
7750 Georgetown Rd. Indianapolis, IN 46268 800 215 9293 www.centralrestaurant.com Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT Stock No. 185 029 Walk in is located indoors, 4" thick
More informationSeries PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection
Series PIC New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction and Renovation; Replaces
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationMiniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.
Miniveyor Tough Fans for Tough Jobs! Where fumes, smells or dust occur, the Miniveyor fans can move contaminated air out of the building. They effectively exhaust fumes, ventilate confined spaces, and
More informationFRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS
FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS 1 PTAC The Frigidaire PTAC Collection offers flexibility for any application. Simple, intuitive controls and options, including remote thermostats, allow users
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationStudent Guide. Wiring Edition. Compliments of. Georgia EMC East Exchange Place Tucker, GA (770)
Student Guide to Wiring 2017 Edition Compliments of Georgia EMC 2100 East Exchange Place Tucker, GA 30084 (770) 270-6950 www.georgiaemc.com Electric Membership Cooperatives of Georgia In Georgia, the 41
More informationElement D Services Electrical
PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.
More informationTypical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating
Process air duct heaters are used for tempering forced air in many industrial processes. Heater wattage is dependent on air outlet temperature (up to 1200 F [650 C]) and air velocity. Smaller duct heaters
More informationCompressed Air Distribution System
Compressed Air Distribution System SmartPipe+ from 3/4 to 2-1/2 kaeser.com SmartPipe+ Compressed Air Piping Kaeser s SmartPipe+ is a modular compressed air distribution system that provides both lower
More informationVACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES
Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete
More informationInstrument Rated Metering Equipment
Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO 640 877.48.54 milbankworks.com MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and
More informationCommercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages
MODEL SE Commercial Electric Water Heater 6-119 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction High Efficiency Polyurethane
More informationPrinciple of Operation:
SELF-REGULATING HEATERS Standard Overjacket Standard Metal Braid Stranded Copper Conductors Self Regulating Conductive Core Thermoplastic Elastomer Jacket Description: Nelson Type CLT selfregulating heater
More informationMODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS
MODEL EH ELECTRIC BOILER EH-08-135S through EH-40-135S 3 wire 120/208V, 120/240V single phase EH-12-345S through EH-40-345S 4 wire 120/208V three phase WYE OPERATION AND INSTALLATION INSTRUCTIONS CONTENTS....................................PAGE
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationOPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D
OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More information