Instrument Rated Metering Equipment

Size: px
Start display at page:

Download "Instrument Rated Metering Equipment"

Transcription

1 Instrument Rated Metering Equipment Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

2 MILBANK OVERVIEW Milbank Overview Energy At Work since 97 Milbank designs and manufactures electrical solutions that move and manage power for the residential, commercial, industrial, utility and transportation sectors. With 90 years of expertise in electrical engineering design and manufacturing, Milbank s portfolio includes metering equipment, enclosures and enclosed controls. Founded in 97, Milbank is a family-owned, American manufacturer headquartered in Kansas City, Mo. For more information, please visit milbankworks.com. METERING As a market leader in electrical metering equipment, Milbank has set the standard for quality since 97. Hundreds of configurations are available, including many sizes, knockout configurations, terminal configurations, bypass options, hubs, locks and connectors. Milbank has the socket you need with thousands of active products to meet your utility s requirements. ENCLOSURES Milbank s line of enclosures include commercial junction boxes, panel mount enclosures, transformer cabinets, wireway, trough and industrial panel mount and push-button enclosures. Built with high-quality craftsmanship and materials which meet or exceed industry standards, Milbank enclosures are made to protect controls and equipment from dust, dirt and other harmful elements found in a wide variety of environments. ENCLOSED CONTROLS Milbank doesn t just build empty enclosures. We can deliver the entire package, complete with custom control equipment built to your exact specifications by our engineers. Milbank commercial pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

3 Table of Contents TABLE OF CONTENTS CT Rated Sockets Plunger bypass features & benefits amp CT rated Prewired CT rated... 0 Multi-position CT rated... Lever bypass CT rated... 4 Demand side management... 5 Stainless steel CT rated... 6 CT Cabinets CT cabinets feature & benefits... 7 Transformer cabinets... 8 Stud & lug type mounting racks... Transformer cabinets with factory-installed CT racks... 4 Metered transformer cabinet... 5 Transockets Transockets features & benefits page... 6 Transockets Pedestals Instrument Rated Pedestal... Instrument Rated Commerical Pedestals... Test Switches Test switches features & benefits... Test switches Test switch worksheet... 6 Miscellaneous Meter Forms Accessories Reference Information Index... 4 Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

4 4 CT RATED SOCKETS CT Rated Sockets Plunger Bypass Feature 4 4 UC77-RL UC7545-RL Highlights and Features These units are available in a powder coated galvanized G90 steel or aluminum R shell. Plunger Bypass: Once meter is removed from socket, plunger bypass disengages and CTs are shunted. Connectors: #4 4 mechanical connectors provided for ease of connecting CT wires. If ring terminal is desired, use U prefix rather than UC. Terminals: Range of 5 to terminal block assemblies available to meet most of your single and three phase application needs. 4 Ringless/Ring Type: Units available in both ringless or ring type styles. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

5 CT Rated Sockets 0 Amp 5- Terminals 5 0 AMP CT RATED SOCKETS UC77-RL 0 Amp CT Rated Sockets Ringless Plunger Bypass Terminals Service Hub Meter Form UC7545-RL Connectors CU UC758-XL Dimensions Knockouts D" W" H" 4 UC90-XL 5 OH/UG C.P. S # UC99-XL 6 OH/UG C.P. 4S # UC7-XL 7 OH/UG C.P. 7, 4, 5 & 4S # UC75-XL 8 OH/UG C.P. 5S # UC77-XL OH/UG C.P. 6, 8, 9S & (ALT) 0S # Amp CT Rated Sockets Ring Type Plunger Bypass Terminals Service Hub Meter Form Connectors CU Dimensions Knockouts D" W" H" UC9-RL 5 OH/UG H.O. S #4-4 MAX UC00-RL 6 OH/UG H.O. 4S #4-4 MAX UC7544-RL 8 OH/UG H.O. 5S #4-4 MAX UC7545-RL OH/UG H.O. 6, 8, 9S & (ALT) 0S #4-4 MAX Amp CT Rated Sockets Ring Type Terminals Service Hub Meter Form Connectors CU Dimensions Knockouts D" W" H" UC758-XL OH/UG C.P. 6, 8, 9S & (ALT) 0S # Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Bypass: Plunger type bypass automatically closes when meter is removed. Connectors: Units are supplied with mechanical type connectors. If compression type connectors are preferred, change catalog prefix to S (i.e. SC7544-RL becomes U7544-RL). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

6 6 0 AMP CT RATED SOCKETS CT Rated Sockets 0 Amp -Piece Cover w/ Test Switch Provision 4 /" " 6 8 APC609-WL shown with test switch not included " APC660-WL 0 Amp -Piece Cover CT Rated Socket with Test Switch Provision* Ringless Terminals Service Hub Connectors CU Meter Form Dimensions Knockouts D" W" H" APC609-WL 5 OH inch # APC660-WL 6 OH inch # Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog. Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. Test Switch Configurations: Contact Factory for different test switch. Smaller Footprint: this unit allows for smaller footprint installations. Shell: Both 609 and 660 come standard with aluminum shell. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

7 CT Rated Sockets 0 Amp -Piece Cover w/ Test Switch Provision 7 0 AMP CT RATED SOCKETS UC7478-RL 0 Amp -Piece Cover CT Rated Socket with Test Switch Provision* Ringless Terminals Service Hub Connectors CU Meter Form Dimensions Knockouts D" W" H" UC744-RL 5 OH/UG H.O. #4-0 S UC7478-RL 6 OH/UG H.O. #4-0 4S UC7444-RL 8 OH/UG H.O. #4-0 5S UC7445-RL OH/UG H.O. #4-0 6, 8, 9 & (ALT) 0S , 4, 4, 4, Hubs: For proper hub selection, see the hub suffix chart on the accessory page. Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog. Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors (#0) are preferred, change catalog prefix to U (i.e. UC7445-XL becomes U7445-XL). *Test Switch Cover: Units on this page are not designed for use with test switch covers without removing test switch bridge prior to installing test switch. Test Switch Configurations: See page 4 for standard test switch configurations and page 5 for utility-specified test switches. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

8 8 0 AMP CT RATED SOCKETS CT Rated Sockets 0 Amp -Piece Cover w/ Test Switch Provision UC7449-RL 0 Amp -Piece Cover CT Rated Socket with Test Switch Provision* Ringless Ring Type Terminals Service Hub Connectors CU Meter Form Dimensions Knockouts D" W" H" UC7446-RL UC7450-RL 5 OH/UG H.O. #4-0 S UC75-RL UC766-RL 6 OH/UG H.O. #4-0 4S UC7448-RL UC7460-RL 8 OH/UG H.O. #4-0 5S UC7449-RL UC746-RL OH/UG H.O. #4-0 6, 8, 9 & (ALT) 0S , 4, 4, 4, Hubs: For proper hub selection, see the hub suffix chart on the accessory page. Sealing Rings: Ring type units are supplied with one MR- snap-type sealing ring. Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog. Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. Connectors: Units are supplied with mechanical type connectors (#4 max). If compression type connectors are preferred, change catalog prefix to S (i.e. UC7449-XL becomes S7449-XL). *Test Switch Cover: Units on this page are not designed for use with test switch covers. Test Switch Configurations: See page 4 for standard test switch configurations and page 5 for utility-specified test switches. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

9 CT Rated Sockets 0 Amp Deeper 5 8" Shell w/ Test Switch Provision 9 0 AMP CT RATED SOCKETS UC4-XL UC4-XL 0 Amp -Piece Cover CT Rated Socket with Test Switch Provision Ringless Ring Type Terminals Service Hub Connectors CU Meter Form Dimensions Knockouts D" W" H" UC45-XL UC45-XL 5 OH/UG C.P. #4-0 S UC46-XL UC46-XL 6 OH/UG C.P. #4-0 4S UC48-XL UC48-XL 8 OH/UG C.P. #4-0 5S UC4-XL UC4-XL OH/UG C.P. #4-0 6, 8, 9 & (ALT) 0S UC44-XL 5 OH/UG C.P. #4-0 9S or 76S , 4, 4, 4, 4, Hubs: For proper hub selection, see the hub suffix chart on the accessory page. Sealing Rings: Ring-type units are supplied with one MR-4 screw type sealing ring. Pre-wiring: If standard factory pre-wiring is required, refer to wiring diagrams in the reference section of this catalog. Determine appropriate diagram and send copy with order. If custom factory pre-wiring is required, consult factory for details. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. Connectors: Units are supplied with mechanical type connectors. If compression type connectors are preferred, change catalog prefix to U (i.e. UC4-XL becomes U4-XL). Test Switch Cover: Units on this page can be used with clear lexan cover. See accessories page for ordering information. Test Switch Configurations: See page 4 for standard test switch configurations and page 5 for utility-specified test switches. EUSERC Approval: All ring-type items on this page are EUSERC compliant. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

10 0 PREWIRED CT RATED SOCKETS Prewired CT Rated Sockets Factory wired to utility specification UC7449-XL-87 For field-installable test switches, see page 5 for standard configurations. Test switches can also be factory installed without prewiring. Consult factory for details. Milbank s CT Rated meter sockets are also available with factory prewiring and customspecified test switches. For factory prewiring and custom test switch configurations, see the worksheet on page 6 and consult factory for details. Available for both ring type and ringless applications. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

11 Multi-Position CT Rated Sockets 0 Amps w/ Test Switch Provision TWO POSITION CT RATED SOCKETS UC45-XL SC60-O-BL Amps Multi-Position CT Rated Sockets Ringless UL Listed Positions Terminals Service Hub Connectors CU Meter Form Dimensions Knockouts D" W" H" UC458-XL* Yes 8 OH/UG C.P. #4-0 5S UC45-XL* Yes OH/UG C.P. #4-0 6, 8, 9 & (ALT) 0S SC600-O-BL- No UG Blank #4-0 6, 8, 9 & (ALT) 0S SC60-O-BL- No UG Blank #4-0 6, 8, 9 & (ALT) 0S , 4,, 4, 4 0 Amps Multi-Position CT Rated Sockets Ring Type UL Listed Positions Terminals Service Hub Connectors CU Meter Form Dimensions Knockouts D" W" H" UC448-XL Yes 8 OH/UG C.P. #4-0 5S , UC44-XL Yes OH/UG C.P. #4-0 6, 8, 9 & (ALT) 0S , UC444-XL Yes 5 OH/UG C.P. #4-0 9S or 76S , Hubs: For proper hub selection, see the hub suffix chart on the accessory page. Sealing Rings: Ring-type units are supplied with one MR-4 screw type sealing ring. Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. Connectors: Units are supplied with mechanical type connectors. If compression type connectors (#0) are preferred, change catalog prefix to S (i.e. UC45-XL becomes S45-XL). The SC600 and SC60 include a section for additional electronic components. Remote CT cabinet required. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

12 0 AMP LEVER BYPASS CT RATED CT Rated Sockets with VT Pack Provision SC68 APC SC Amps Transformer Rated Sockets VT Pack Provision Ringless Terminals Service Hub Connectors CU Dimensions Knockouts D" W" H" SC68 OH/UG H.O. #4 - #4 Max SC69 UG Blank #4 - #4 Max None 4, SC65 8 OH/UG C.P. #4 - #4 Max SC66 OH/UG C.P. #4 - #4 Max VT pack compatible bridge provision provided Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

13 Lever Bypass CT Rated Sockets 80 Amps Ringless 600 VAC 80 AMP LEVER BYPASS CT RATED U4490-XL U449-XL 80 Amps Transformer Rated Sockets Lever Bypass Ringless Terminals Service Hub Connectors CU Bypass Dimensions Knockouts D" W" H" 4 5 U4490-XL 6 OH/UG C.P. #4 - #4 Max Lever , U449-XL 8 OH/UG C.P. #4 - #4 Max Lever , U449-XL OH/UG C.P. #4 - #4 Max Lever , Hubs: For proper hub selection, see the hub suffix chart on the accessories page. Bypass: Lever operates current bypass device and also supplies clamping action on current meter spades. Connectors: Units are supplied with mechanical type connectors (#4 max). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

14 4 0 AMP LEVER BYPASS CT RATED Lever Bypass CT Rated Sockets 0 Amp Ringless w/ Test Switch Provision U4497-XL U4496-ZL-WC-4 0 Amp Ringless -Piece Cover Lever Bypass CT Rated Socket with Test Switch Provision Terminals Service Hub Connectors CU Dimensions Knockouts D" W" H" U4494-XL 6 OH/UG C.P. #4 - #4 Max U4496-XL 8 OH/UG C.P. #4 - #4 Max U4497-XL OH/UG C.P. #4 - #4 Max , 4, 4, Pre-wiring: If factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch model and number, and meter form number. Please be sure to provide a copy of your wiring diagram. Connectors: Units are supplied with mechanical type connectors (#4 max). Test Switch Cover: Units on this page can be used with clear lexan cover. See accessories page for ordering information. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

15 Demand Side Management 00/0 Amps 4 Terminals Ringless 5 DEMAND SIDE MANAGEMENT 4 48 U48-O- Application The right position is used for sub-metering by the serving utility when a special electric rate is given to customers for devices that can shed load during high energy demand. Contact your local utility for more information. Features Low voltage compartment in lower right corner Left position is a 00 amp, 4 terminal heavy duty lever bypass interior Right position is 0 amp rated with a fifth terminal in the 9 o clock position and a plunger bypass Right position is pre-wired to the terminal strip for easy installation 00/0 Amps 4 Terminals Two Positions Off-Peak Metering Connectors / CU Dimensions Knockouts Service Left Side Bypass Right Side D" W" H" 4 (Line & Load) U48-O- UG #6-50 Terminal Strip Lever/Plunger , Fifth Terminal: For field installed fifth terminal on left (00 amp) side, order catalog number K866. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

16 6 STAINLESS STEEL CT RATED Stainless Steel CT Rated 0 Amps with Test Switch Provision 4 4 UCSS4-O part number isn t supposed to have knockouts. I ed elliot to get it fixed. 0/5 0 Amps Ringless CT Rated Socket with Test Switch Provision Stainless Steel Dimensions Terminals Service Hub Connectors CU Cover Knockouts D" W" H" UCSS4-O OH/UG Blank #4 - # Max -Piece None 0 Amps Ring Type CT Rated Socket with Test Switch Provision Stainless Steel Terminals Service Hub Connectors CU Cover Dimensions D" W" H" Knockouts UCSS4-O OH/UG Blank #4 - # Max -Piece None For Conduit Opening Applications: All conduit openings have dimples provided to center location. Top conduit opening must have water-tight hub installed. Other Stainless Steel Products: Most units available in stainless steel contact Milbank for details. EUSERC Approval: The UCSS4-O is EUSERC compliant. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

17 CT Cabinets Features & Benefits U5990-O Highlights and Features (Window-style CT not included) Powder Coat Painted NEMA R Shell: As with all Milbank products, our enclosures are constructed of G90U galvanized steel and finished with an attractive, light gray, baked powder coating. Our state-of-the-art finish combines epoxy and polyester hybrid resins into a hybrid powder coating which is then electrostatically applied. This offers a durable, non-fading finish. Three-Point Latching Handle & Locking Mechanism: Padlocking handle with three-point latching system allows for easy locking and securing of the unit. Hinged Double Doors: Hinged overlapping double doors enhance ease-of-access and are secured with three-point latching system. Bar-Type CT Rack: Includes pre-placed studs to mount bar-type CTs. Withstand rating is 50K. Lugs: Line, load and neutral rack lugs are single 600 kcmil or twin 50 kcmil. Grounding Lug: Single position, 50 kcmil. Some units available in stainless steel contact Milbank for details. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

18 8 TRANSFORMER CABINETS Current Transformer Cabinets Continuous Hinge Padlock Provision Current Transformer Cabinets Type R Gauge Steel Dimensions Panel Size Painted Steel Panel W" H" D" W H Wood Backboard 40-LCR-SP A-4P A-4PW 060-LCR-SP A-6P0 A-6P0W 60-LCR-SP A-P6 A-P6W 66-LCR-SP A-6P6 A-6P6W 466-CTR A-4P6 A-4P6W PT Cabinets Dimensions D" W" H" Knockout Material PT48L " - right side Steel PT48AL 8 6 " - right side Aluminum PT48R " - left side Steel PT48AR 8 6 " - left side Aluminum PT48AR* S7860 Features: Supplied with studs, continuous hinge and padlock provision. Steel panels and plywood backboard are optional. LCR-SP: Indicates a single door with two padlockable wind handles. *PT48: PT48L and PT48AL has mounting emboss on the right side to be mounted on left side of CT cabinet. PT48R and PT48AR have mounting emboss on left side to be mounted on right side of CT cabinet. Pole Mounting: For pole mounted CT rack applications, order catalog number S7860. There are other sizes of outdoor transformer cabinets available, contact Milbank or refer to our enclosures catalog for details. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

19 Transformer Cabinets CT and PT Cabinets 9 TRANSFORMER CABINETS Application For use as a current transformer cabinet or panel enclosure. For outdoor use to provide protection against rain, sleet and snow, or indoor use to protect against dripping water. Construction 66-CTR Enclosure and cover manufactured from 6 or 4 gauge G90U galvanized steel. The doors are overlapping with no center post. Continuous door hinge with stainless steel hinge pins. Three point pad-lockable handle. Panel mounting studs provided for optional back panels. Drip shield top and seam-free sides, front and back. Finish ANSI 6 gray polyester powder coating over phosphatized G90U galvanized steel. Current Transformer Cabinets Panel Enclosure Dimensions Weight W" H" D" Steel Panel # Wood Panel # 060-CTR A-6P0 A-6P0W 600-CTR A-6P0 A-6P0W 606-CTR A-6P0 A-6P0W 660-CTR A-6P6 A-6P6W 66-CTR A-6P6 A-6P6W 666-CTR A-6P6 A-6P6W 4400-CTR A-0P44 A-0P44W 486-CTR A-48P6 A-48P6W 4866-CTR A-48P6 A-48P6W 4848-CTR A-48P48 A-48P48W 6060-CTR A-60P60 A-60P60W Wall or Pole Mount: For wall or pole mount CT rack order S7860. This unit accomodates donut style CTs. The removable cover makes wiring much easier. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

20 0 TRANSFORMER CABINETS Current Transformer Cabinets Compatible with Field Installable Racks Screw Cover Note CT49-SC C.T. Racks C.T. Racks CT06-HC Dimensions Dimensions Front Cover D" W" H" CT49-SC A4, C, D, G, J, M 9 4 Piece CT44-SC G 4 4 Piece CT40-SC A4, C, D, G, J, M 4 0 Piece CT46-SC A4, C, D, G, J, M 4 6 Piece CT448-SC A, C, D, G, J 4 48 Piece CT00-SC A4, B4, C, D, E, F, G, H, J, K, L, M 0 0 Piece CT06-SC A4, B4, C, D, E, F, G, H, J, K, L, M 0 6 Piece CT66-SC A4, B4, C, D, E, F, G, H, J, K, L, M 6 6 Piece CT64-SC A, B, C, D, E, F, G, H, J, K, L, M 6 4 Pieces CT648-SC A, B, C, D, E, F, G, H, J, K, L, M 6 48 Pieces CT44-SC A, B, C, D, E, F, G, H, J, K, L, M 4 4 Pieces CT4848-SC A, C, D, G, J, M Pieces CT064-SC A4, B4, C, D, E, F, G, H, J, K, L, M Pieces CT6484-SC A, B, C, D, E, F, G, H, J, K, L, M Pieces CT48484-SC A, B, C, D, E, F, G, H, J, K, L, M Pieces Hinge Cover Front Cover D" W" H" CT06-HC A4, C, D, J 0 6 Piece CT40-HC A4, C, D, G, J, M 4 0 Piece CT46-HC A4, C, D, G, J, M 4 6 Piece CT448-HC A, C, D, G, J, M 4 48 Piece CT06-HC A4, B4, C, D, E, F, G, H, J, K, L, M 0 6 Piece CT048-HC A, B, C, D, E, F, G, H, J, K, L, M 0 48 Piece CT66-HC A4, B4, C, D, E, F, G, H, J, K, L, M 6 6 Piece CT648-HC A, B, C, D, E, F, G, H, J, K, L, M 6 48 Piece CT4848-HC B4, E, F, H, K, L Pieces CT6484-HC A, B, C, D, E, F, G, H, J, K, L, M Pieces CT48484-HC A, B, C, D, E, F, G, H, J, K, L, M Pieces Enclosure: These units are rated Type R, powder coated, and constructed of galvanized steel. Mounting Rack: Select CT mounting rack by matching the appropriate letter in CT rack column with applicable letter in Code column on page. Mounting: /4-0 welded studs. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

21 CT Cabinet Mounting Racks Stud & Lug Types Meets EUSERC standard CT CABINET MOUNTING RACKS K4797 K47 K479 / K4795 Current Transformer Enclosure Mounting Racks Code AIC Rating amp Volts Type of Service Termination Type K4797 A4 50K ØW / x Studs on -/4" Centers K4797 A 50K ØW / x Studs on -/4" Centers K4798 B4 50K Ø4W / x Studs on -/4" Centers K4798 B 50K Ø4W / x Studs on -/4" Centers K479 C 0K ØW / x Studs on -/4" Centers K4795 D 0K ØW / x Studs on -/4" Centers K4794 E 0K Ø4W / x Studs on -/4" Centers K4796 F 0K Ø4W / x Studs on -/4" Centers K479 G 50K ØW () #4-600 or (6) # - 50 K47 H 50K Ø4W () #4-600 or (6) # - 50 K490 J 50K ØW () #4-600 or () # - 50 K4904 K 50K Ø4W () #4-600 or () # - 50 K5747 L 50K Ø4W K575 M 50K ØW CT racks on this page are for use with bar type CTs. Line: / x Studs on -/4"Centers Load: () #4-600 or (6) # - 50 Line: / x Studs on -/4"Centers Load: () #4-600 or (6) # - 50 Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

22 CT CABINET MOUNTING RACKS CT Cabinet Mounting Racks Stud & Lug Types Non-EUSERC K59 K59 K590 K59 Current Transformer Enclosure Mounting Racks Code SCCR Rating Amps Volts Type of Service Termination Type N K590 50K Ø4W () #4-600 or (6) #-50 P K59 50K ØW or ØW () #4-600 or () #-50 Q K59 50K ØW or ØW "- studs on 4" centers R K59 50K Ø4W "- studs on 4" centers Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

23 Current Transformer Enclosures amps AMP CURRENT TRANSFORMER ENCLOSURES U855-O-NE Current Transformer Enclosures Amperage Rating Hub Steel Gauge Connectors CU/AL Dimensions D" W" H" U855-O-NE Blank connectors per phase 6 6 U856-O-NE Blank 5 connectors per phase Features: These enclosures have three-point locking handles, lift-off hinges with stainless steel pins and two doors. Type R rated. Connectors: Minimum #4, maximum 600 mcm. U855 and U856 both come from the factory with isolated neutrals. Bonding straps are included but not attached with each 855 and 856 if isolated neutral is not needed. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

24 4 400 & 800 AMP TRANSFORMER CABINETS Current Transformer Cabinets 400 & 800 Amps U4468-XT U5990-O Current Transformer Cabinets Ø U4468-XT U4468-XT-K4469 K4469 kit installed U5990-O 800 Ampacity Wiring Chart Dimensions Hub Wire Qty. Aluminum Copper Amps Per Phase Conductor Conductor D" W" H" kcmil kcmil /0 () C.P kcmil kcmil /0 () C.P kcmil 600 kcmil or -50 or -50 Blank Hubs: U4468 is supplied with two closing plates as standard. To order hubs, refer to the accessories section. Studs: The U4468 is supplied with "- twin studs with hex nuts with Belleville washers to mount bar-type transformers. 800 Amp Conversion Kit: To convert U4468 from 400 amps to 800 amps, order catalog number K4469. Padlock: The U4468 is provided with a padlockable -point latch. The U5990 is provided with a padlockable handle with -point latching mechanism. Withstand Rating: 50K SCCR available when conductors are lashed per instructions on label. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

25 Metered Transformer Cabinets Screw Cover Ring Type 5 METERED TRANSFORMER CABINETS U565-O Metered Transformer Cabinets Ring Type Terminals Service Hub Compatible CT Racks (see pg. for matching code) Type of Service Dimensions Knockouts D" W" H" U0-R 6 OH H.O. A, C, D, G, J, M ØW U-R OH H.O. A, B, C, D, E, F, G, H, J, K, L, M Ø4W Y or Δ U555-R 5 OH H.O. A, B, C, D, E, F, G, H, J, K, L, M Ø4W Y or Δ U40-O 6 UG Blank A, C, D, G, J, M ØW U4-O UG Blank A, B, C, D, E, F, G, H, J, K, L, M Ø4W Y or Δ U565-O 5 UG Blank A, B, C, D, E, F, G, H, J, K, L, M Ø4W Y or Δ Meter Socket: 0 amp current transformer meter socket built in. Enclosure: NEMA Type R with screw cover. Current Transformer Mounting: 4 0 welded studs. Hubs: For proper hub selection, see hub suffix chart in the accessories section. Sealing Rings: Supplied with MR-4 screw type sealing ring. Lugs: For mounting rack information, refer to page. Test Switches: These units include test switch provision to mount above or below CT rack. Will accept 7 or 0 pole test switches. EUSERC Approval: All units on this page are EUSERC compliant. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

26 6 TRANSOCKETS Transockets Features & Benefits AP604-O-400-NKO- Highlights and Features Transocket Overhead/Underground Capabilities: From the factory, the rack is oriented for underground applications but can be rotated 80 for overhead applications. The neutral lugs can be mounted on the side for overhead applications. The VT pack mounting bridge moves from the top to the right side for overhead applications NEMA R Aluminum Shell: The alumnium shell reduces the overall weight of the unit compared to a steel shell. Shell is powder coated. Meter Socket & Test Switch on Swinging Door: Unit includes a -terminal CT-rated block. An 8-terminal block option is also available. Includes a 0-pole test switch. A 7-pole test switch option is also available. Factory pre-wired to conform to individual utility specifications. Utility-Specific Wiring Harness: Wiring harness is color configured and wired per the utility specifications. VT Pack Mounting Bridge: VT pack mounting bridge allows for installation of VT packs. Wall Mount Bracket: Provides an easier means of installation for one installer, who can premount the bracket and then hang the unit onto the wall bracket. Stainless Steel Liftoff Handles: The durable, rust-resistant hinged handles lay flat against the front. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

27 Transockets Amps Ringless 600 VAC AMP TRANSOCKETS S957-X S674-XT S890-XT Amps Transockets Bar Type CTs Only Ringless 600 VAC Terminals Meter Form Hub CTs Qty. and Ratio Termination Type Dimensions Knockouts D" W" H" S957-X 6 4S C.P. () 00/5 Lay-in lugs , S8-XT 6 4S () C.P. () 00/5 Lay-in lugs S690-XT 8 5S () C.P. () 00/5 Lay-in lugs S674-XT 8S () C.P. () 00/5 Lay-in lugs Amps Transockets With PTs and Donut Type CTs Ringless 600 VAC Terminals Meter Form Hub PTs Qty. and Ratio CTs Qty. and Ratio S89-XT 8 5S () C.P. () 4: () 00/5 Termination Type Dimensions Knockouts D" W" H" Lugs mounted directly to current transformer Hubs: To order hubs as extra, refer to the hub suffix chart in the accessories section. Prewiring: Units supplied prewired with test switch and transformers in place. Contact factory if prewiring is desired. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

28 8 TRANSOCKETS Transockets Compatible with CTs, PTs, or VT Packs AP604-O-400-NKO (shown factory prewired) S777-4X (shown factory prewired) Amps 8 & Terminals Ringless Transocket Terminals Service Phase Test Switch Hub VT Pack Provision CTs Qty. & Ratio Dimensions D" W" H" Knockouts *AP605-O-400-NKO 8 OH/UG Ø or ØW 7-pole Blank Yes () 400/ None AP604-O-400-NKO OH/UG Ø4W 0-pole Blank Yes () 400/ None Shell: Shell is painted aluminum and R rated. Prewiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio. VT Pack Provision: VT pack bridge included; VT pack not included. Removable/Rotatable CT Rack: These units include a CT rack which can be rotated 80 degrees for both overhead or underground applications. Wall Mount Bracket: Bracket included for ease of hanging and installation. Lugs: Lugs are included with these units. *ØW Delta configurations order kit K Amps 4 Terminals Ringless Ø4W Transocket Terminals Service Test Switch Hub PTs Quantity & Ratio CTs Quantity & Ratio Dimensions Knockouts D" W" H" S777-4X 4 OH/UG 0-pole (4) C.P. ().5: () 400/ S8-4X 4 OH/UG 0-pole (4) C.P. None () 400/ Hubs: Units supplied with 4 closing plates as standard. To order hubs as extra, refer to the accessories page. Pre-wiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio, and PTs if applicable. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

29 Transockets 400 Amps 600 VAC AMP TRANSOCKETS U5944-XT (shown factory prewired) U6-XT 400 Amps 6 Terminals Ringless Transockets Terminals Service Front Cover Phase Test Switch Hub Dimensions Knockouts D" W" H" U8-XT 6 OH/UG Hinged Ø Provision () C.P U9-XT 8 OH/UG Hinged Ø or ØW Provision () C.P U6-XT OH/UG Hinged Ø4W Provision () C.P U5944-XT OH/UG Lift-off Ø4W Provision () C.P Hubs: Units are supplied with two closing plates as standard. To order hubs as extra, refer to the accessories page. Shell: Shell is powder-coat painted G90 galvanized steel and R rated. Pre-wiring: If custom factory prewiring is required, be sure to specify test switch requirements, meter form number and provide a copy of your wiring diagram. If CTs are to be factory installed, specify CT ratio. There is no provision for PTs in these cabinets. Studs: "- twin studs are supplied to mount bar type transformers. Hex nuts with Belleville washers are also supplied. Lugs: Lugs are included with these units. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

30 0 00/400/800 AMP TRANSOCKETS Transockets 00/400/800 Amps 600 VAC U46-XT--LI U46-XT--LI /400/800 Amps 6 & Terminals Transockets Ringless Terminals Service Amps Hub Connectors Dimensions Knockouts Phase Line Load D" W" H" * U4554-X-Z-LI 6 OH/UG 00/400 C.P. #4-600 #4-600 Ø U4554-X-Z-K6SP-LI 6 OH/UG 00/400 C.P. () #6-50 () #6-50 Ø U466-XT-Z-LI 6 OH/UG 400/800 C.P. #4-600 #4-600 Ø U45-X-Z-LI OH/UG 00/400 C.P. #4-600 #4-600 Ø U45-X-Z-K6SP-LI OH/UG 00/400 C.P. () #6-50 () #6-50 Ø U46-XT--LI OH/UG 400/800 C.P. #4-600 #4-600 Ø *Knockout #: This is a 8" hole with plastic plug, not a concentric knockout. Lugs: Lugs are provided and are rated up to single 600 kcmil - #4 AWG. Short Circuit Current Withstand Rating: These units have a 50K short circuit current withstand rating. Units furnished with /"- studs, washers and hex nuts and bolt with conical washer for CT mounting. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

31 Instrument Rated Pedestal 0 Amps Terminals With Test Switch Provision INSTRUMENT RATED PEDESTAL S4084-O Ringless Instrument Rated Pedestal With Test Switch Provision Connectors Dimensions Knockouts Terminals Hub Meter Form Bypass CU D" W" H" S4084-O Blank 6, 8, 9 & (ALT) 0S #4 /0 None Contact factory for details. Also available in 6 & 8 terminals. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

32 Instrument Rated Commercial Pedestals INSTRUMENT RATED PEDESTAL Attractive Easy to Install Secure Cost-effective Milbank Commercial Pedestals are pad-mounted, weather resistant electrical enclosures consisting of a utility pull section with optional meter socket, and a customer section containing distribution and control equipment. Milbank Commercial Pedestals are an attractive, secure, easy to install and cost-effective solution when underground remote site power distribution and control equipment is required, replacing unsightly and inefficient strut and backboard structures. Standard Features Type R rain resistant, vandal resistant cabinet of powder-coated steel (aluminum or stainless steel also available) UL-listed as enclosed industrial control equipment (UL508) Isolated lockable & sealable utility metering and lug landing sections Lockable customer section for distribution and control equipment with internal deadfront Print pocket inside customer section door contains wiring schematics and installation instructions All stainless steel external hardware (screws, bolts, hinges, handles, hasps and sealing screws) Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

33 Test Switches Features & Benefits Highlights and Features Handle Color Options: Standard colors are black for current and red for potential. Many non-standard colors are available contact Milbank for details. Handle material is polypropylene. 45 Degree Stops: 90 degree bends on 45 degree stops are standard. 80-degree bends are available where additional strength is required. Test Switch Barriers: Test switch barriers are made of polycarbonate as standard. Test Switch Covers: Polycarbonate (clear or black). Test switch cover is clear when factory-installed unless otherwise specified. Test Switch Base: Test switch bases are red as standard and made of glass polyester. Arboron Test Switch Base & Barriers Option: Base and barriers are available in Arboron, a thicker and more rigid material that provides extra strength. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

34 4 TEST SWITCHES Test Switches Details & Test Switch Covers Switch Blades Two dimples coined into one side of the switch blade ensure positive contact in corrosive, sooty environments even after years of inactivity. Test Switch Covers Standard test switch covers are made from impact resistant clear thermal plastic which has excellent tracking and moisture resistant properties. If covers are required, add suffix -WC (with cover) to the catalog number or order separately catalog number K88. Black flush mount covers are also available. Order catalog number K88-BLK-FL. 0 pole base only. Standard Cover Test Switch Base The base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track resistant, flame retardant and has low water absorption qualities. Bases are available in 7 pole and 0 pole sizes. Switch Jaws The switch blade jaw clips are constructed from spring grade copper alloy. The material and design ensure excellent contact which prevents overheating. Nickel Plating Option Corrosion-resistant test switches with nickel plating are available as an option. Socket shells must be 5 8" deep -ORmust not have test switch bridge mounted on back in order to support a cover. Polarity Barrier For maximum protection potential circuits are supplied with permanently mounted barriers made from high tensile strength polycarbonate. Current Carrying Parts Highly conductive copper and copper alloy materials are used on all current carrying parts. This ensures conductivity and deters corrosion. Spring grades are used where appropriate. Plating is available if required. Contact Milbank for to special order. Flush Mount Cover (Black) Factory Installed: For cover installed add the suffix -WC or -WCB to the catalog number of desired test switch. Field Installed: For field installed cover order kit number K88 or K88-BLK-FL. The Milbank test switch is designed to meet the critical requirements of the electric utility industry. Not only do they meet EEI, ANSI C.9, and UL standards but they combine several special features giving the Milbank test switch increased safety, durability and reliability. One such feature is our unique switch blade contact points which cut through residue that builds up after years of service. Another distinction is our polarity barrier which is designed to be flexible as well as offer exceptional insulating qualities. Our test switches are constructed from the latest materials available using modern fabricating and assembly methods. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

35 Test Switches 4, 7 & 0 Pole 5 TEST SWITCHES /" 7 /" /" 9 /" P C C N Pn X Key Potential Switch Line side current switch with short circuit assembly Load side current switch with test jack assembly Neutral bar (no switch) Neutral Potential Switch Unused Position on base Insulating barrier, isolates both sides of switch 4-Pole TS04-00 X P Pn X C C X TS X C C X P Pn X 7-Pole TS P P Pn C C C C Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussing is required, different catalog numbers will apply. 7-Pole on a 0-Pole Base TS P X P X Pn X C C C C TS X P C C P C C Pn X X 0-Pole TS0-009 P P P Pn C C C C C C TS0-00 P C C P C C P C C Pn TS0-0 P P P Pn C C C C C C TS0-0 C C C C C C P P P Pn TS0-006 P P P Pn C C C C C C Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

36 6 TEST SWITCH WORKSHEET Test Switch Worksheet Electronic version available at milbankworks.com Customer Name: Address: Phone / Handle Color Key BK Black P Purple Y Yellow GN Green R Red BL Blue W White BKS Black Stripe BR Brown GR Grey O Orange WS White Stripe TEST SWITCH BASE The base is molded from a high strength, fiberglass reinforced, thermoset polyester. This material is track-resistant, flame-retardant and has low water absorption qualities. Bases are available in two standard sizes following NEMA mounting classifications. Pole Position Chart Special Features Feature Angle Stops Ganged Handles (C) Bussing Colored Handles Engineering Information: P C C N Pn X Key Potential Switch Line side current switch with short circuit assembly Load side current switch with test jack assembly Neutral bar (no switch) Neutral Potential Switch Unused Position on base Insulating barrier (one side) Insulating barrier (two sides) Custom Pole Arrangements: The key may be used to diagram your own pole arrangement. Be sure to specify base size and whether all C line side, current switch / shunt circuit assemblies are to be bussed together. The catalog numbers shown above are connected in line-load pairs; therefore, if bussed is required, different catalog numbers will apply. of Poles q q q q Other Test Switch Cover (only available for 0-pole bases) q q Yes Clear Black No Base Size q q 7-Pole 0-Pole Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

37 Watthour Meter Forms Standard Forms Transformer Rated or Self-Contained 7 WATTHOUR METER FORMS SC SC TR TR TR and -WIRE FORMS S & S and -WIRE FORMS S & S with BYPASS -WIRE FORM S 5th Term. 9 o clock -WIRE FORM S with BYPASS -WIRE FORM S 5th Term. 6 o clock TR SC SC SC SC -WIRE FORM S with BYPASS ELEMENT -WIRE NETWORK FORM S 5th TERM. 9 o clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 9 o clock ELEMENT -WIRE NETWORK FORM S 5th TERM. 6 o clock ELEMENT -WIRE NETWORK FORM S with BYPASS 5th Term. 6 o clock TR TR SC SC TR -WIRE FORM 4S -WIRE FORM 4S WITH BYPASS or ELEMENT Ø4W Y or Y FORM 4S FORM 5S Y FORM 6S or ELEMENT Ø4W Y or FORMS 4S & 5S with BYPASS ELEMENT Ø4W Y or Y FORM 7S FORM 4S with BYPASS TR TR SC SC TR ELEMENT ØW, Ø4W, ØW FORM 5S ELEMENT ØW, Ø4W, ØW FORM 5S with BYPASS ELEMENT ØW, Ø4W, ØW FORM S or ELEMENT ØW, Ø4W, ØW FORM S with BYPASS or ELEMENT Ø4W Y or Y FORM 9S FORM 8S TR = TRANSFORMER RATED SC = SELF CONTAINED TR TR TR or ELEMENT Ø4W Y or FORMS 8S & 9S FORMS 8S & 9S with BYPASS ELEMENT Ø4W Y FORM 6S ELEMENT Ø4W Y FORM 6S with BYPASS Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

38 8 METER FORMS Meter Forms Reference Information DIAGRAM A W with P.T. & C.T. Single Stator Meter(W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM B W with C.T. Single Stator Meter (W ) - Form S 5T Socket, Test Switch #TS04-00 DIAGRAM C W with C.T. s Single Stator Meter (W ) - Form 4S 6T Socket, Test Switch #TS DIAGRAM D W or W Network with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM A DIAGRAM B DIAGRAM C DIAGRAM D (ALT.LOC.) (ALT.LOC.) P PN C C P PN C C P P C C C C P P C PN C C C P.T. I LINE N (BONDED) C.T. LOAD I LINE N (BONDED) C.T. LOAD I LINE N (BONDED) C.T. C.T. LOAD I LINE N (BONDED) C.T. C.T. LOAD DIAGRAM E W with P.T. s & C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM F W with C.T. s Stator Meter - Form 5S 8T Socket, Test Switch #TS DIAGRAM G 4W Y with C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM H 4W Y with P.T. s & C.T. s Stator Meter - Form 6S T Socket, Test Switch #TS0-009 DIAGRAM E DIAGRAM F DIAGRAM G DIAGRAM H P P PN C C C C C C P P PN C C C C C C P P P C C C C P C P P C C C LINE PT PT C.T. C.T. LOAD LINE C.T. C.T. LOAD LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT LINE N (BONDED) C.T. LOAD C.T. C.T. DIAGRAM I 4W Y or with C.T. s Y Stator Meter - Form 9S Stator Meter - Form 8S T Socket, Test Switch #TS0-009 P P P PN C DIAGRAM I C C C C C DIAGRAM J 4W Y with P.T. s & C.T. s Stator Meter - Form 9S T Socket, Test Switch #TS0-009 P DIAGRAM J P PN C P C C C C C Prewiring: If standard factory prewiring is required, refer to wiring diagrams on this page. Determine appropriate diagram and send a copy with order. If custom factory prewiring is required, specify on order. Be sure to include meter socket catalog number, test switch make and catalog number, meter form number and provide a copy of your wiring diagram. LINE N (BONDED) C.T. LOAD C.T. C.T. PT PT PT LINE N (BONDED) C.T. LOAD C.T. C.T. Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

39 Accessories Hubs and Closing Plates 9 ACCESSORIES -RL Small hub opening -WL A754 -YL A755 -ZL A756 -DL A757 -EL A758 -XL A755 " hub 4" hub " hub " hub " hub Small closing plate -R Large hub opening -F A80 -G A8 -H A8 -X A9064 -RRL S84 " hub " hub 4" hub Large closing plate Large hub opening adapted to small hub oepning Suffix: Add to catalog number for factory installation of hub. Packaging: Individually packed units for field installation. Abbreviations: H.O. (hub opening), C.P. (closing plate). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

40 40 ACCESORIES Accessories Closing Covers, Sealing Rings and Touch-Up Paint Closing Covers Sealing Rings Meter Closing Plate (Ring Type / Ringless) Metal Closing Plate (For Ringless Sockets) Grey Plastic CP Clear Plastic MR- - Snap Action MR-SS - Stainless Steel MR-4 - Screw Type (Stainless Steel) Touch-Up Paint A-GP - Light Grey Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

41 Energization of Electrical Equipment Important Information for Installers 4 ENERGIZATION OF ELECTRICAL EQUIPMENT Important Note In addition to national and local electrical codes, many utilities have specific requirements for metering equipment. Always consult the serving utility for their specifications and requirements prior to ordering or installing Milbank meter mounting equipment. Before Energizing A. Give equipment a thorough visual examination to determine that: ) No shipping or installation damage exists. ) Proper clearances have been maintained. ) All connections have been made. 4) Equipment is clean and dry. B. Make a thorough examination to: ) Verify tightness of all bolted connections (see table below). ) Manually operate all circuit breakers, switches, relays, etc. ) Check rigidity of all mountings, bus bars and components. 4) Use test equipment to check continuity of circuitry and integrity of insulation. C. All switches and circuit breakers should be in the off position. D. Verify that manual meter bypass (if applicable) is in non-bypass position. E. Install cover and/or close doors. F. If installation is not being energized at this time, follow after-energizing steps listed below. These steps will secure the installation in case of accidental energization. When Energizing A. Use caution and follow established safety procedures: ) Wear safety apparel. ) Use safety equipment. ) Take action to prevent injury to yourself and others in the event of failure of the installation. 4) Take action to prevent/decrease damage to property in the event of failure of the installation. 5) If you are unsure how to safely energize the installation, get someone who is knowledgeable to do it. After Energizing A. Secure the installation: ) To prevent accidental contact with energized parts, cover all openings with approved filler devices. ) To prevent unauthorized access, secure all covers and/or doors with approved security devices. ) Attach/post information to advise others of potential hazards associated with the installation. Recommended Torque for General Applications* Nominal Joint Description Torque Head Type Size Screw Nut (Inch Lbs.) 0 Brass Brass Nut or Extruded Hole All 0-5 inch lbs. 0 Steel Copper or Aluminum Busbar /8" All 5-0 inch lbs. 0 Steel Steel Nut or Extruded Hole; CU or AL Busbar > /8" All 0-5 inch lbs. Steel Aluminum Extruded Hole All 0-5 inch lbs. Steel Steel Nut or Extruded Hole All inch lbs. /4 Steel Aluminum Extruded Hole All inch lbs. /4 Steel Steel Nut or Extruded Hole; CU or AL Busbar All inch lbs. 5/6 Steel Aluminum Extruded Hole Hex inch lbs. 5/6 Steel Steel Nut or Extruded Hole; CU or AL Busbar Hex inch lbs. /8 Steel Steel Nut Hex inch lbs. / Steel Steel Nut Hex inch lbs. * Interior labels typically indicate the required torque for wire connectors and studs, and should be referenced first. CU: Copper AL: Aluminum Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

42 4 MATERIALS & FINISHES Materials & Finishes Reference Information Materials Steel Quality The meter equipment listed in this catalog is made of galvanized steel (AISI* G90) to afford the best possible weather proofing. *American Iron and Steel Institute. Steel Sheet 6 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. (AISI G90) 4 gauge, galvanized, sheet: /4 oz./ sq.ft. class zinc-coated. Aluminum Extrusion Wire-Terminals: Alloy; 606-T6, Tin-plated for CU/AL wire. Bus Bar: Alloy; 60-O & 606-O Aluminum Sheet 000 series aluminum sheet, H4, or 505 series aluminum sheet, H. Where applicable thicknesses range from Copper Sheet & Bus Electrolytic copper with tin plating in most applications. Insulating Materials In most units, support bases for current-carrying components are molded from fiberglass reinforced high-strength, track resistant, thermoset polyester molding compounds. Clear or black safety shields and polarity barriers are molded from high-strength, track resistant, polycarbonate molding compounds. Various sheet insulating materials, as appropriate for the application are utilized in the fabrication of flat, formed and punched component parts and barriers. Finish Process Light gray state-of-the-art electrostatically applied powder paint offers a durable, non-fading finish. For further information concerning the chemical analysis of the weather resistant finish, please contact the factory. Metal Fastners Zinc-coated with a chromate dip. Ratings & Compliance Ratings & Compliance All Milbank electrical enclosures in this catalog are rated Type R Enclosure unless specified otherwise on the product s page. All enclosures with a UL designation are constructed per the appropriate UL Standard and may be installed per the National Electric Code. UL procedure files associated with the UL Standards are listed as follows: Meter Sockets (UL 44, File E00), Test Switches (UL 44, File E65), Power Outlets (UL, File E90945), Panelboards (UL 67, File E68) and Pullout Switches (UL 49, File E06). Additional standards are utilized as applicable: Meter Sockets (ANSI C.7), Test Switches (ANSI C.9) and Panelboards (NEMA PB-). Milbank Manufacturing 480 Deramus Ave., Kansas City, MO milbankworks.com

PART GENERAL 1.01 SECTION INCLUDES

PART GENERAL 1.01 SECTION INCLUDES Specification Number: 26 24 16.06 Product Name: Emergency Lighting Control NQ Circuit Panelboards: 240 Vac, 48 Vdc Maximum SECTION 26 24 16.06 Emergency Lighting Control NQ Circuit Panelboards: 240 Vac,

More information

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,

More information

Where technical minds provide innovative solutions

Where technical minds provide innovative solutions Where technical minds provide innovative solutions From Utility Company (ConEd, PSE&G, etc) Service End Box CT Cabinet Custom Crown/ Pull Boxes Internal Construction (Example) Service Entrance Distribution

More information

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low voltage power panelboards 1.02 RELATED SECTIONS 1.03 REFERENCES

More information

Type MTS Miniature Test Switches

Type MTS Miniature Test Switches Type MTS Miniature Test Switches Compact and versatile Front- and back-connected styles Safe, durable, rugged and reliable Recognized by CUL & UL Class IE qualified per IEEE Standard 33-1974 DESCRIPTION

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill

More information

MaxGard. Interconnection Systems. Durability. Performance. Safety

MaxGard. Interconnection Systems. Durability. Performance. Safety 8Russellstoll Pin and Sleeve Power Connectors Safety Different power supply ratings can t mix: 24 single-rate device polarizations ensure exact voltage, frequency and phase differentiation Safe connections:

More information

Heavy Industrial/Marine MaxGard

Heavy Industrial/Marine MaxGard 6 Heavy Industrial/Marine MaxGard MaxGard Interconnection Systems Overview Defined Any application where electrical connections need protection from water and/or dust ingress to contacts or wiring compartment

More information

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices. SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance

More information

MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET

MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET LIGHTING SERVICE CABINET TYPE: L1 & L2 02/02 /2012 Page 1 of 21 SPECIFICATIONS FOR L1 & L2 LIGHTING SERVICE CABINETS Table of Contents 1. General

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION

SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION INTRODUCTION 1. All group-operated switches installed shall be load-break. The interrupters are now included with the plates and no longer need to be itemized as in the past. The identification plates

More information

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5

More information

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard SARGENT Manufacturing Company 2004, 2007 All rights reserved Fire Guard Table of Contents Features and Additional Fire Opening Devices............................1 2408 Single-Point Hold Open

More information

SECTION ELECTRICAL GENERAL PROVISIONS

SECTION ELECTRICAL GENERAL PROVISIONS PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling

More information

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Installing the Cisco ONS FAP-4 Fuse Alarm Panel Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document

More information

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures PART 1 GENERAL 1.1 WORK INCLUDED Section 27 11 00 COMMUNICATION EQUIPMENT ROOM FITTINGS Section 27 11 16 Communications Cabinets, Racks, Frames and Enclosures A. Provide all labor, materials, and equipment

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.

More information

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications: CONTROLLER CABINETS, POLE MOUNTED - Item No. Special Provision No. 682S27 June 2017 1. SCOPE This Special Provision covers the requirements for the installation of pole mounted controller cabinets and

More information

2408/2900. Fire Guard

2408/2900. Fire Guard 2408/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2408 Single-Point Hold Open Applications and Mounting Details... 2 2408 Track Assemblies, Arms and Components...

More information

8. Multi-Family Residential Buildings

8. Multi-Family Residential Buildings Mu lti-f a mily Re s id e n tia lbu ild in g s 2016 Electric Service Requirements, 3rd Edition Section 8 Section 8 Multi-Family Residential Buildings Directory Page 8.1 General 61 8.2 Maximum Available

More information

2409/2900. Fire Guard

2409/2900. Fire Guard 2409/2900 Fire Guard Table of Contents Features and Additional Fire Opening Devices... 1 2409 Single-Point Hold Open Applications and Mounting Details... 2 2409 Track Assemblies, Arms and Components...

More information

ASCO Series 185 Power Transfer Switches

ASCO Series 185 Power Transfer Switches ASCO Series 185 Power Transfer Switches 24-hour protection no matter when trouble strikes ASCO Series 185 POWER TRANSFER SWITCHES An Automatic Transfer Switch helps prevent... Your business or home from

More information

CHAPTER 20 SERVICE EQUIPMENT

CHAPTER 20 SERVICE EQUIPMENT SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control

More information

PANELBOARDS & BUILDING DISTRIBUTION

PANELBOARDS & BUILDING DISTRIBUTION 262416 PANELBOARDS & BUILDING DISTRIBUTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Distribution panelboards 2. Power panelboards B. Related Sections: 1.02 POLICY 1. CU Standard 260500, Basic

More information

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

Thermal Devices, Inc. Mount Airy, Maryland USA   C D E F. Typical Maxiband Clamping Maxiband Heaters The Most Sought After Band Heater A B Maxiband General purpose terminal box offers excellent protection to the exposed terminals. To simplify electrical wiring, the box has two 1/2" trade

More information

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

CADDY CORPORATION. Utility Distribution Systems

CADDY CORPORATION. Utility Distribution Systems Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which

More information

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting

More information

Installation Instructions

Installation Instructions Installation Instructions Self-Cleaning Radiant Electric Drop-In Range JDP47, JD968, JD900 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before You Begin Read these instructions

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

2 PREPARE THE OPENING

2 PREPARE THE OPENING Installation Instructions 27 & 30 Electric Built-In Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca

More information

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Band Heaters W A T L O W. Special Mica Barrel and Nozzle W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge

More information

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions 30 French Door Built-in Wall Ovens Installation Instructions 30 French Door Built-in Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca DESIGN

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS

More information

Applications and Features

Applications and Features 120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans, Heaters & Solid State Dual Point Temperature Controller Model: NB181608-1HFS Applications and Features Features: Molded Fiberglass

More information

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc. Technical Manual VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater Provided by: Chart Inc. 407 7th Street NW New Prague, MN 56071 USA (800) 400-4683 Part Number 20977233 Rev. A 2016 Chart Inc.

More information

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

Installation Instructions

Installation Instructions 30" Built-In Wall Oven JTP20, JTP25, JTP28, JTP48, JTPh0, JT912, JT915, JT952, JT955, ZET938, ZET958 If you have questions, call 1.800.GE.CARES www.geappliances.com or visit our website at: Before You

More information

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:

More information

B-LINE SERIES. Product brochure. Firestop

B-LINE SERIES. Product brochure. Firestop Product brochure B-LINE SERIES 3M Fire barrier self-locking pillows Extremely easy to install saves time and labor Easy removal and fully reusable with no blocking or fusing of materials No cutting required,

More information

SECTION ELECTRICAL IDENTIFICATION

SECTION ELECTRICAL IDENTIFICATION SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

Marathon Special Products

Marathon Special Products Marathon Special Products Fused Disconnect Switch Specifications 30 amps 600 volts AC Line/Load #4-18 AWG Factory & Field Wiring Minimum indicator voltage 90V-AC Din-Rail mountable on any 35mm wide rail

More information

SECTION SANITARY SEWAGE PUMP STATIONS

SECTION SANITARY SEWAGE PUMP STATIONS SECTION 11303 SANITARY SEWAGE PUMP STATIONS PART 1 GENERAL 1.1 DESCRIPTION: This work shall include the construction of a sewage pumping station complete with all pumping and electrical equipment, all

More information

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. Installation Manual For 1200ACXX models: For 120XAC-IMXX models: 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator. 12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. The letter X, in the model

More information

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

SECTION (16140) - WIRING DEVICES

SECTION (16140) - WIRING DEVICES SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -

More information

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications Special Applications Air Conditioning & Air Handling Units For more than 55 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 49). A wide

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS

More information

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call  2-1/2 Pipe Thread Heaters Pipe Thread Heaters Construction Features " -/" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging hex, thread and riser assures reliability.

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets

More information

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects SPEC-00042 Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects WATERSHED DISCONNECT ENCLOSURE, TYPE 4X INDUSTRY STANDARDS Mounting brackets required to meet UL/cUL external

More information

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects 763.422.2600 Spec-00042 J763.422.2211 Wall-Mount Preferred-Cutout s Hoffman WATERSHED Wall-Mount s Wall-Mount Preferred-Cutout s Hoffman WATERSHED Wall-Mount s WATERSHED Enclosure, Type 4X INDUSTRY STANDARDS

More information

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER Ilnstallat!on nstruct=ons Built-In Wall Oven with Microwave 27" (68.6 cm) model JKP90 30" (76.2 cm) models JTP90, PT970 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before

More information

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. L Type Anchor Bolt Carbon Steel AISI 304 S.S. ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut

More information

Two (2) Side Rail Cable Tray

Two (2) Side Rail Cable Tray O-1 B-Line series Cable Tray Systems 3M Fire Barrier Self-Locking Pillows Extremely easy to install - saves time and labor Easy removal and fully reusable - with no blocking or fusing of materials No cutting

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating. SECTION 15890 DUCTWORK PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal ductwork. B. Duct cleaning. 1.2 RELATED SECTIONS A. Section 09900 - Painting: Weld priming, weather resistant, paint or coating. B.

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X

FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X 763.422.2600 SPEC-00216 J763.422.2211 OUTSIDE PLANT PRODUCTS FIBER OPTIC CABINETS FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X Door Switch 19-or 23-inch rack mounting including cabinet entry boots Ground

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure Enclosure INTRODUCTION The Model FH-2071-UM Enclosure from., used in Marine applications is robust and weather-resistant. Its durable design is customized

More information

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41 Dryer User manual DV22K6800** DV22K6800-03650A-00_EN (US)_151211.indd 1 2015-12-11 7:15:41 Before installation Read through the following instructions before installing the dryer, and keep this manual

More information

your dust explosion protection experts

your dust explosion protection experts your dust explosion protection experts HMI Overview Camera Systems Pag. 2 Remote I/O Barriers & Isolators Pag. 3 Purge Pag. 3 Plugs & Receptacles Lighting Pag. 5 Control Stations Pag. 6 Terminal Boxes

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete

More information

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1 FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1 Hotfoil, Inc. Robbinsville, NJ 08691 Phone: 609.259.4118 / Fax : 609.259.4119 http://hotfoil.com TABLE OF CONTENTS I Product Specification

More information

MODEL PR16 POWER ROTARY

MODEL PR16 POWER ROTARY MODEL PR16 POWER ROTARY OPERATION, PARTS & MAINTENANCE MANUAL 6926 Smithville Hwy. McMinnville, TN 37110 Phone: 931-934-2211 Fax: 931-934-2200 Email info@tennsmith.com www.tennsmith.com Proudly Made in

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications Special Applications Air Conditioning & Air Handling Units For more than 50 years, INDEECO has been supplying special heaters for use in air handling and air conditioning equipment (Figure 50). A wide

More information

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts. EXUB Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts. Forced-Air Heater for Hazardous Locations Class I, Divisions 1 & 2, Groups

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 9100 SERIES ARCHITECTURAL DRAFT BARRIER WALL AND PEDESTAL MOUNT INSTALLATION INSTRUCTIONS CAUTION: HIGH TEMPERATURES KEEP ELECTRICAL CORDS, FURNITURE, DRAPERIES OR ANY OTHER BLOCKING MATERIAL AWAY FROM

More information

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,

More information

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications

More information

Installation Instructions

Installation Instructions 4 3 Installation Instructions Self Cleaning Free-Standing Electric Range EER2000, EER3000, EER3001, EER3002, JBP10, JBP24, JBP26, JBP30, JBP35, JBP48, JBP64, JBP66, JBP68, JBP69, JBP71, JBP78, JBP80, JBP82,

More information

McDONALD S 30 ROOF ELEMENT

McDONALD S 30 ROOF ELEMENT 29-10 7/16 PRE-DRILLED HOLES IN LEGS 4-8 15/16 1-7 1/4 MCDO BRACKET 1-7 1/4 RIVNUT NALDS BRACKET 10-8 2 1-7 1/4 = DISTANCE FROM BOTTOM OF BASE PLATE TO CENTER OF TIE-BACK ASSEMBLY C L 22 1/16" FROM WALL

More information

Pathway Lighting. Introduction

Pathway Lighting. Introduction The Encore Landscape Lighting System combined with Encore s superior products will create beauty, safety, and security all in a simpleto-install system. The Encore Landscape Lighting System allows for

More information

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00 I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

FOR TM-16 EMERGENCY WARNING SYSTEM

FOR TM-16 EMERGENCY WARNING SYSTEM INSTALLATION AND INSTRUCTION MANUAL FOR TM-16 EMERGENCY WARNING SYSTEM SPECIAL NOTE BOONE CABLE WORKS & ELECTRONICS, INC. 1773-219 TH LANE P.O. BOX 429 READ THIS ENTIRE BOOKLET BOONE, IOWA 50036 USA BEFORE

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. September 2012, rev. 00 26 2416 Panelboards PART 1. GENERAL 1.01 Summary A. Section includes: 1.02 Definitions 1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR September 2012, rev. 00 26 0553 Identification for Electrical Systems PART 1. GENERAL 1.01 Summary A. Section Includes: 1.02 Submittals 1. Identification for raceways. 2. Identification of power and control

More information

An ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device

An ASSA ABLOY Group brand Series. Electromechanical Closer-Holder Releasing Device An ASSA ABLOY Group brand 4200 Series Electromechanical Closer-Holder Releasing Device introduction The 4200 Series Electromechanical Closer-Holders combine the functions of an electromechanical door holder

More information

7200 Series. Electromechanical Closer/Holder Releasing Devices

7200 Series. Electromechanical Closer/Holder Releasing Devices 7200 Series Electromechanical Closer/Holder Releasing Devices INTRODUCTION The 7200 Series Electromechanical Closer/Holders combine the functions of an electromechanical door holder with the 7700 series

More information

SECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:

SECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including: SECTION 16050 BASIC ELECTRICAL MATERIALS AND METHODS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes basic electrical materials and methods including: 1. Conduit, fittings and accessories. 2. Wire,

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information