1 Specifications for Electrical Installations and Supplements Errata and Revisions September 2010 for the Electric System Bulletin 750 Series Covering National Grid s Service Areas in MA, NH, NY, and RI NOTICE: This publication contains changes and corrections to the Company s Specifications for Electrical Installations, the ESB Book, and its supplements. This is periodically issued when the need arises. The most current information on a topic will therefore be a combination of the base document listed in this table of contents and the current version of this list. Upon periodic revision of a base document herein referenced, all list items associated with that base document will be removed.

2 SECTION TABLE of CONTENTS PAGE TABLE of CONTENTS... 2 GENERAL NOTICE...3 ESB NO (VERSION 1.0, 04/20/2010) SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS (UPSTATE NY, MA, NH, AND RI)...3 NEW ENGLAND GREEN BOOK (JULY 2000) ELECTRICAL SERVICE INFORMATION AND REQUIREMENTS...5 ESB NO (NOVEMBER 2003) APPROVED METER SOCKETS AND OVERHEAD SERVICE ATTACHMENT BRACKETS...5 ESB NO , 2 ND PRINTING APRIL 2002 SERVICE ABOVE 15,000 VOLTS...5 ESB NO , 2 ND PRINTING APRIL 2002 PRIMARY METER POLE...6 ESB NO. 754A-1992, 2 ND PRINTING JUNE 2002 SINGLE PHASE OUTDOOR PAD MOUNTED TRANSFORMER...6 ESB NO OUTDOOR PAD MOUNTED OR VAULT ENCLOSED THREE PHASE TRANSFORMER...6 ESB NO OPERATION & MAINTENANCE REQUIREMENTS FOR SERVICES ABOVE 600 VOLTS...9 ESB NO GENERAL REQUIREMENTS FOR PARALLEL GENERATION CONNECTED TO A NATIONAL GRID OWNED EPS...10 ESB NO. 756 APPENDIX A; 2007 REQUIREMENTS FOR PARALLEL GENERATION CONNECTED TO NATIONAL GRID FACILITIES IN NY...10 ESB NO. 756 APPENDIX B; 2007 REQUIREMENTS FOR DG CONNECTED TO NATIONAL GRID S RADIAL DISTRIBUTION PER THE NYS SIR...10 ESB NO. 756 APPENDIX C; 2007 REQUIREMENTS FOR PARALLEL GENERATION CONNECTED TO NATIONAL GRID FACILITIES IN MASSACHUSETTS...10 ESB NO. 756 APPENDIX D; 2007 REQUIREMENTS FOR PARALLEL GENERATION CONNECTED TO NATIONAL GRID FACILITIES IN RHODE ISLAND...10 ESB NO. 756 APPENDIX E; 2007 REQUIREMENTS FOR PARALLEL GENERATION CONNECTED TO NATIONAL GRID FACILITIES IN NEW HAMPSHIRE...11 ESB NO. 757, AUG NETWORK SERVICES...11 ESB NO. 758, JAN PRIMARY SERVICE TO METAL ENCLOSED GEAR...11 ESB NO REVISION HISTORY ESB750ER0910.doc Page 2 of 17

3 General Notice P.S.C. No. 220: P.S.C. No. 220 Schedule for Electric Service ("P.S.C. No. 220 Electricity Tariff") supersedes and replaces former P.S.C. No. 207 Schedule for Electric Service ("P.S.C. No. 207 Electricity Tariff") effective April 27, 2009 ("Effective Date"). As of the Effective Date, all references to P.S.C. No. 207 Electricity Tariff in agreements existing as of the Effective Date shall be construed as references to P.S.C. No. 220 Electricity Tariff. The Rule Numbers, Forms, and Service Classifications in P.S.C. No. 220 Electricity Tariff as of the Effective Date are identical to those of P.S.C. No. 207 Electricity Tariff as of the day immediately prior to the Effective Date, but Leaf Numbers may differ. To avoid any possible ambiguity resulting from this change, references to Leaf Numbers in P.S.C. No. 207 Electricity Tariff in agreements existing as of the Effective Date shall be construed as references to the equivalent Leaf Numbers for the same Rule Numbers, Forms, and Service Classifications in P.S.C. No. 220 Electricity Tariff. Therefore, all references to P.S.C. No. 207 in any of the Company s ESB 750 series bulletins shall be construed as references to P.S.C. No. 220 (see: ESB No (Version 1.0, 04/20/2010) Specifications for Electrical Installations (Upstate NY, MA, NH, and RI) 11 Electric Service Areas Sep-2010 Add the following web link below the Massachusetts map: p_meco.pdf Sep-2010 Add "operating" before "demands" in second sentence Sep-2010 In second sentence, the word "laterals" was cut off. 43 Figure Sep-2010 Remove 48", 18", and 32" horizontal dimensions from Figure , which are not related to the intent of this section. 45 Figure Sep-2010 Add 50 ft. maximum length to service drop Figure Sep-2010 Change the figure s title to read as follows Figure Typical Underground Service Post for Permanent or Temporary Service Below 600 volts Sep-2010 Add the following notes to the table: Notes to Table : 1 Vertical clearance values for conductors are for 100 ft. (30.0 m) spans at 60 F (15 C) final unloaded sag and phase-to-ground voltages. No allowance is made for sag for vertical clearances at a building or structure's point of attachment. Consult the Company for clearances required for longer spans. 2 Vertical clearance above roadways subject to truck traffic may have higher requirements based on the highway authority having jurisdiction. 3 A roof, balcony, or area is considered readily accessible to pedestrians if it can be casually accessed through a doorway, ramp, window, stairway, or permanently mounted ladder by a person on foot who neither exerts extraordinary physical effort nor employs tools or devices to gain entry. A permanently mounted ladder is not considered a means of access if its bottom rung is 8 ft. (2.45 m) or more from the ground or other permanently installed accessible ESB750ER0910.doc Page 3 of 17

4 PAGE SECTION EFFECTIVE CHANGE surface. 4 Where the height of a residential building does not permit its service drop(s) to meet these values or where clearances are compromised, please consult the Company. 5 Consult the Company if work may be expected in the future near lines or between the building and lines. The clearance shall be increased to ensure 10 ft. (3.0 m) minimum clear space for electrically unqualified persons, tools, machinery, and equipment or the line must be deenergized, guarded, and marked-up as required by safety codes. The clearance shall consider space required when ladders or scaffolding are to be used when maintaining the building or structure. The Customer will be responsible for any charges incurred by the Company to provide safe clearances for Customer activity Sep-2010 Add the following notes to the table: Notes to Table : 1 Vertical clearance values for conductors are for 100 ft. (30.0 m) spans at 60 F (15 C) final unloaded sag and phase-to-ground voltages. No allowance is made for sag for vertical clearances at a building or structure's point of attachment. Consult the Company for clearances required for longer spans. 2 For 750V to 22kV Open Supply Cables, 26.5 ft. (8.1 m) applies for the first row and 18.5 ft. (5.7 m) applies for the second row clearance requirements. Consult the Company for overhead line clearances to swimming pools to identify the line construction and operating voltage. 3 When a Customer s pool installation fails to maintain the required NESC safety clearances from the Company s overhead conductors, the Customer (or the installer) shall bear the costs of correcting the NESC violations by 52 Table Sep-2010 relocating the pool or the Company s overhead lines. Add the following note after the table For single-phase, 200A and less service drops, a 2 inch (53) rigid galvanized steel conduit riser may be permitted providing it is braced with a 5/16 (8mm) steel guy wire. See Section when considering alternative installation methods and materials Sep-2010 Add the following new last paragraph: In Upstate NY where there are no jurisdictional requirements for licensed electricians, the Company will permit individuals with qualifications as outlined in the National Electrical Code (NEC) to disconnect and temporarily reconnect a residential overhead service on the customer side of the service point under the same conditions stated above. Refer to the Company s Web site at overhead.asp for details and the procedure to permit and schedule this work Sep-2010 Add to last sentence in first paragraph of Section "and no more than 2 for each service connection". Add another sentence to the end of the first paragraph For conductor sizes greater than 500kcmil, the Customer will be responsible to provide the Company with connectors if necessary to connect to overhead transformers. ESB750ER0910.doc Page 4 of 17

5 Sep-2010 Add the following new last sentence to the first paragraph: A clear working space of at least four feet (1.2 m) shall be provided and maintained in front of all meter socket covers; however, shall not be less than 3 ft. (0.9 m) to a property line Sep-2010 Delete last (fourth) paragraph of Section Figure Sep-2010 Add For Commercial Only above note By-Pass Lever in the By-Passed Position. 80 Figure Sep-2010 Add Position at the end of the figure s title Figure Sep-2010 Remove the word Figure at the end of the figure s title. Add "and refer to Section for more information" to the end of the last sentence in Figure Figure Sep-2010 Delete the redundant title below the figure s title Sep-2010 Change the third sentence in Section to read as follows: This will require the installation of a double-throw, breakbefore-make type switch or similar disconnecting device acceptable to the Company; see Section Sep-2010 Move the last paragraph below the figure in Section to be the last paragraph in Section Figure APP1-2 Sep-2010 Correct the right side table list as follows: ITEM DESCRIPTION I-25 3, 600V Insulator B7A2 2-1/2 (65 mm) Expansion Shield Lag Screw (Zinc Alloy) B11A 3/8 (10 mm) X 3 (75 mm) Lag Screw B11B 3/8 (10 mm) X 4 (100 mm) Lag Screw B13 5/8 (16 mm) Machine Bolt W1 2-1/4 (57 mm) Square Flat Washer New England Green Book (July 2000) Electrical Service Information and Requirements Superseded in April 2010, refer to ESB ESB No (November 2003) Approved Meter Sockets and Overhead Service Attachment Brackets Superseded in April 2010, refer to ESB New ESB 751 General Requirements for Services Above 600 volts is presently being developed. ESB No , 2 nd Printing April 2002 Service above 15,000 volts 6 I.G.4.b Jul-2002 Move first sentence of second bullet to Section I.G.4.c. 7 I.G.4.c Jul-2002 After the second sentence, insert first sentence of I.G.4.b s second bullet. 15 V.F.1 Nov-2002 Add the following before the first sentence in V.F.1: The Company shall review and accept the protective relay devices provided by the Customer for protection schemes required by the Company to protect its system. The use of utility grade relays and relay redundancy is a normal Company ESB750ER0910.doc Page 5 of 17

6 PAGE SECTION EFFECTIVE CHANGE requirement. 15 V.F.3 Nov-2002 Change V.F.3 to read as follows: 3. Company-designated protective devices The Company will review for acceptance the Customer s proposed settings of those relays that the Company's System Protection Engineering Dept. designates as being required to satisfy the Company s protection practices. Any relay setting accepted by the Company shall not be changed or modified at any time without the prior written consent of the Company. 16 V.F.5 Nov-2002 Change V.F.5 to read as: The Customer is responsible for specifying the relay settings and performing the calibration, testing, maintenance and trouble-shooting of their entire protective system. The Customer shall provide written notice to the Company prior to energization that these items have been verified. ESB No , 2 nd Printing April 2002 Primary Meter Pole Figures 3 through 4 Note 4 Apr-2009 The johnny ball guy insulator is no longer acceptable as they do not meet present insulation requirements for this type of installation. Fiberglass guy strain insulators are now specified. Ensure the guy insulators are placed to prevent the transfer of energy from the Company s wires to (i) the Customer wires, (ii) any communication wires on the pole or (iii) the public on the ground. Depending on spacings on the pole, multiple guy insulators may be needed to meet the multiple requirements. Consult the Company for inquiries regarding the design, equipment, and installation of the pole guy. ESB No. 754A-1992, 2 nd Printing June 2002 Single Phase Outdoor Pad Mounted Transformer Superseded in April 2010, refer to ESB and ESB 754. See also ESB 759 for the Company s primary cable installation requirements in the Customer s trench or underground conduit system. ESB No Outdoor Pad Mounted or Vault Enclosed Three Phase Transformer Remove all references to ESB 759 effective in April 2010, refer to ESB and new ESB 759. See ESB 759 for the Company s primary cable installation requirements in the Customer s trench or underground conduit system. In addition, 19 Figure 2 Note 6 Sep-2010 Add Note to A, add to bullet 4 in B propane / LP or LNG gas, and add bullet 5 in B chemical storage silos / tanks to read as follows: 6. Clearances from objects: A. An area measuring 10 feet from any point of the ESB750ER0910.doc Page 6 of 17

7 PAGE SECTION EFFECTIVE CHANGE transformer pad shall be kept free of all: buried water lines, storm drainage lines, gas lines, other electric lines; underground fuel storage tanks; and above grade fire hydrants, cell towers, self contained diesel or diesel byproduct fueled generators, and outdoor enclosed generators. NOTE: The 10 ft. clearance may be reduced with a noncombustible barrier (see Note 3) and shall not be less than five (5) feet from the edge of the transformer pad. The Customer or their authorized representative shall obtain this clearance reduction approval from the Company and the local AHJ(Authority Having Jurisdiction), as necessary, prior to the noncombustible barrier installation. B. An area measuring 25 feet from any point of the transformer pad shall be kept free of all: exposed water lines, gas piping, sewer lines; open conductor electric lines; above grade gas meters or regulator vents, fuel storage tanks or dispensing units, and non-enclosed gasoline/ propane / LP or LNG gas fueled generators; and chemical storage silos / tanks. NOTE: The 25 ft. clearance may be reduced to 10 ft. with a noncombustible barrier (see Note 3) and shall not be less than five (5) feet from the edge of the transformer pad. The Customer or their authorized representative shall obtain this clearance reduction approval from the Company and the local AHJ (Authority Having Jurisdiction), as necessary, prior to the noncombustible barrier installation. 31 Figure 11 Sep-2010 Replace typical manhole requirements drawing with updated ground wire; see * below. 32 Figure 11 (cont d) Sep-2010 Replace typical manhole requirements continuation drawing with updated proper ground wire and detail Y; see * below. * See below. ESB750ER0910.doc Page 7 of 17

8 FIGURE 11: TYPICAL MANHOLE REQUIREMENTS ESB750ER0910.doc Page 8 of 17

9 FIGURE 11 (CONTINUED) ESB No Operation & Maintenance Requirements for Services Above 600 volts No errata. ESB750ER0910.doc Page 9 of 17

10 ESB No General Requirements for Parallel Generation Connected to a National Grid Owned EPS PAGE SECTION EFFECTIVE Table of Apr-2009 Contents Table of Contents CHANGE Correct title of Appendix C to: Requirements for Parallel Generation Connected to National Grid Facilities in Massachusetts Apr-2009 Correct last Appendix number to: Appendix E ESB No. 756 Appendix A; 2007 Requirements for Parallel Generation Connected to National Grid Facilities in NY No errata. ESB No. 756 Appendix B; 2007 Requirements for DG Connected to National Grid s Radial Distribution per the NYS SIR Sep-2010 Delete process illustration due to revised NYS SIR, July 2010 and add Refer to the process steps located in Section I at of the New York State Standardized Interconnection Requirements and Application Process for New Distributed Generators 2 MW or Less Connected in Parallel with Utility Distribution Systems. The NYS SIR, July 2010 prevails where there may be a process difference from ESB 756 Appendix B. ESB No. 756 Appendix C; 2007 Requirements for Parallel Generation Connected to National Grid Facilities in Massachusetts 45 Apr-2009 On page 45, change the Web site address to: ariff.pdf#nameddest=interconnection. ESB No. 756 Appendix D; 2007 Requirements for Parallel Generation Connected to National Grid Facilities in Rhode Island 136 Apr-2009 Change the Web address so the paragraph will read as follows: Refer to Narragansett Electric Company Standards for Connecting Distributed Generation, R.I.P.U.C. No 2007 at: _standards.pdf, Effective March 2008, which describes the process and requirements of Narragansett Electric for those instances when a Customer desires to connect a customerowned Generating Facility to Narragansett Electric s Distribution System. ESB750ER0910.doc Page 10 of 17

11 ESB No. 756 Appendix E; 2007 Requirements for Parallel Generation Connected to National Grid Facilities in New Hampshire 137 Apr-2009 Change the Web address so the paragraph will read as follows: For net-metered generators sized less than 25 KVA, see PUC900 at: %20Metering.pdf For all other generators, refer to the Massachusetts Department of Telecommunications and Energy (MDTE) document No A, effective April 2, 2007 contained in Appendix C of this document. ESB No. 757, Aug Network Services Nov-1999 Change 800 amperes and above at 480Y/277 volts to 480Y/277 volts Nov-1999 Delete the Local Authority Approval part in its entirety Nov-1999 Delete paragraphs 94, 97 and 100. ESB No. 758, Jan Primary Service to Metal Enclosed Gear 2 C Nov-1999 Delete the Inspection part in its entirety. Paragraph 11 3 H Nov-1999 Delete Paragraphs 18 through 20 and Paragraph and 5 I Nov-1999 Delete Paragraphs 23 through J Nov-1999 In the first sentence, change outdoor to indoor. Paragraph M Sep-2010 Change this metering section in its entirety and replace it with the new information ** below. Fig. 1 Note #3 Apr-2002 In Note 3, change see Paragraph 18 to see ESB 750 Section 4. Fig. 1 Note #4 (new) Sep-2010 Add new note: Note #4: The clearances shown from the front of the service equipment to a building wall and from the rear of the service equipment to a building wall shall be both 10 foot (minimum) if the switchgear is designed with the Company required access to the incoming termination compartment on one side while the metering PT/CT compartment is on the other side; see Figure 1A. Otherwise, if the Company s access to both compartments is on the same side, then the other side s clearance can be reduced to the clearances presently shown. Add new Figure 1A ** below. ** See below. M. PRIMARY SWITCHGEAR METERING COMPARTMENTS SPECIFICATIONS M.1 Equipment Furnished by the Company ESB750ER0910.doc Page 11 of 17

12 1. The Company will furnish all meters, metering instrument transformers, potential transformer primary fuses and test devices required for billing purposes at the delivery voltage. 2. The Company will specify the quantity and type, of all current and potential transformers for billing purposes. 3. The current and potential transformers for the Company's billing meters shall normally not be used to operate any other Customer devices, see ESB 750, Section 7. M.2 Customer s Responsibility 1. Codes, Standards, and Wiring Adequacy: a. Components of the primary switchgear metering transformer compartment shall conform to the latest editions of the following national standards and codes: Component Applicable National Standard Cable ICEA Power Switchgear ANSI C Power and Instrument Transformers ANSI C57 Surge Arrestors ANSI C62 Insulators ANSI C29 Apparatus Bushings ANSI C76 b. The Company recommends approval certification by a laboratory testing organization acceptable to the authority having jurisdiction according to the National Electrical Code, e.g. UL, ETL, CSA, etc. 2. Metering Transformer Equipment Compartment: a. A separate enclosing compartment shall be provided solely for the billing metering transformers. The metering transformer compartment shall be solely accessible by the Company. The Customer shall have provisions for the Company s locking the access door with a 3/8 (10 mm) shank padlock. b. The connection of the Customer's auxiliary transformer for heat, light and receptacle(s) installed at the meter panel location and elsewhere within their switchgear, shall be on the load side of the Company s billing metering transformers. c. Where the metering transformer compartment is located in an unheated area or building, provisions shall be made for heating the compartment to prevent condensation. d. The entire metering compartment shall be designed and constructed with adequate ventilation. e. The minimum width of the metering transformer compartment must be based on the electrical clearances of Figure M-1. The Customer shall maintain a minimum 10 ft. (3.0 m) unobstructed clearance in front of the metering transformer compartment access door. f. The Customer shall provide space and supports for the Company's current and potential transformers as part of the service entrance equipment. Provisions for mounting shall be designed in a manner that is easily accessible for work. The supports shall be drilled for fixed-in-place mounting hardware (i.e. nuts, bolts, washers) in accordance with dimension information concerning this equipment furnished to the Customer for the design of their installation. Suspending instrument transformers from the roof area of the switchgear shall not be permitted. ESB750ER0910.doc Page 12 of 17

13 In MA, NH, and RI, the current transformers shall be in a completely barriered and isolated compartment from the potential transformer compartment; see Figure M-1A. This compartment shall be so designed that, after proper electrical isolation, each of the current transformers can be readily removed or changed without disturbing the others. Company personnel must have access for inspection without interruption of service. g. The Company's potential transformers (PTs or VTs) for metering healthcare facilities shall be mounted on drawout carriages to ensure that the equipment will be readily accessible for safe inspection and replacement without causing an outage. Where potential transformers are mounted on a drawout carriage, the front of the carriage shall extend up, to close the section when transformers are in the operating position. Primary contacts for the drawout feature shall be of a design that ensures continued maintenance of the contact pressure. Visible grounding devices shall be provided to make certain that the drawout carriage mounted potential transformer primary terminals are grounded when the carriage is withdrawn. The drawout carriage frame must be grounded to the switchgear ground throughout its travel. h. Primary fuses for the Company s potential transformers will be supplied by the Company. The Company will specify if primary fuses shall be separately mounted, in holders supplied by the switchgear manufacturer, and installed in a properly barriered compartment completely isolated from adjoining equipment. Sufficient working space shall be provided to permit fuses to be readily and safely checked or replaced without removing the transformer from its mount. Fuse replacement must be accomplished without interruption of service to the customer. i. No instrument transformers shall be installed closer than 6 inches (150 mm) to the ground or floor upon which the switchgear is installed. j. Instrument transformers shall be installed in such positions that the rating and polarity marks are readily and safely readable. k. The metering transformer compartment shall be solely accessible by the Company. This requires section-to-section openings for through bus to be maintained as small as phase to ground clearances in Figure M-1 will allow. l. Where the clearances in Figure M-1 cannot be provided, Glastic (NEMA Type GPO 3 material) barriers are required between potential transformers and between potential transformers and the enclosure walls. m. Connections for the Company s potential transformers shall be made on the supply side of the current transformers except for generator producing facilities. A connection shall be made available by the Customer from each phase bus with a #6 AWG copper solid wire including crimped connectors and hardware to connect the Company s metering potential transformers. n. The phase bus shall be mechanically independent of the instrument transformers. Company metering transformers are not to be used as part of the bus support system. Removable bus bars shall be furnished by the Customer to permit installation and removal of current transformers. If aluminum bus is used, tin-plated or silver-plated terminals shall be provided by the Customer including silicon-bronze bolts and stainless steel nuts and washers for connection of the Company s metering current transformers. o. A grounding stud shall be provided for grounding each phase of the bus on the line side and load side of the metering transformers and mounted such ESB750ER0910.doc Page 13 of 17

14 that removal of instrument transformers does not affect the ground provisions. The Company will specify the ground stud to be used. p. A 5/8" (16 mm) dia. by 24" (600 mm) long copper ground bail shall be connected to the ground bus at both ends and located 7" (175 mm) behind the door and 5" (125 mm) above the door sill. In MA, NH, and RI, ground pads and "jug handles" shall be installed on the equipment ground bus as shown in Figure M-1A. 3. Metering Conduit: The Customer shall furnish, install and maintain rigid conduit for the wiring from metering transformers to the billing meter panel. The maximum distance between meter and potential transformers shall be 50 feet (15 meters). a. Internal: Where the billing meter panel is part of the switchgear and the conduit is internal between sections, this conduit shall be 1-1/2" (41), PVC Sched. 80 with bushings on each end. b. External: The rigid conduit shall be at least 1-1/2" (41) galvanized steel. The conduit run is permitted a maximum of two 90 degree conduit bends (condulets shall not be used). c. A pull line shall be installed in the conduit. 4. Billing Metering Panel: a. Outdoor Billing Compartment: (where switchgear is located greater than 50 feet (15 meters) from the Customer s building) Note: These requirements apply to a compartment of the Customer s primary switchgear or to a separate free-standing outdoor cabinet. (1) The compartment s minimum dimensions shall be 48" (1.2 m) wide x 90" (2.3 m) high x 24" (600 mm) deep. For a separate free-standing outdoor cabinet the minimum dimensions shall be 48" (1.2 m) wide x 60" (1.5 m) high x 24" (600 mm) deep. (2) The internal panel shall be 3/4" (19 mm) thick x 44" (1.1 m) wide x 60" (1.5 m) high minimum painted exterior grade plywood. (3) The Customer shall install a 1-1/2 inch (41) rigid galvanized steel conduit from the Company s metering transformer compartment to the Company billing meter cabinet. (4) The billing metering compartment shall be lighted (75 watt minimum), contain a 20A GFI protected 120/240VAC duplex receptacle, be heated (250 watt minimum, thermostatically controlled), and be ventilated. (5) The compartment door shall include a three point latch and provisions for a 3/8 (10 mm) shank padlock by the Company. (6) The Customer s switchgear heater control circuitry equipment shall be located in this compartment. b. If Utility Meters are being installed inside: (1) The Customer shall install a 1-1/2 inch (41) rigid galvanized steel conduit from the Company s metering transformer compartment to the Company approved meter location. (2) The Customer shall provide and mount a meter board for each indoor installation as illustrated in Section 7 of ESB 750. ESB750ER0910.doc Page 14 of 17

15 Figure M-1 Typical Primary Switchgear Metering Transformer Compartment Clearances ESB750ER0910.doc Page 15 of 17

16 For MA, NH, and RI: Figure M-1A Typical Primary Switchgear Metering Transformer Compartments ESB750ER0910.doc Page 16 of 17

17 Figure 1A Clear Area Requirements in Front of Line Termination and Metering Transformer Compartments for 15kV Class Primary Switchgear ESB No. 759 Superseded in Oct by ESB 754. New ESB 759 Underground Distribution Guidelines is presently being developed. REVISION HISTORY Version Date Description of Revision /27/10 First version of new document superseding all previous issues of the ESB 750 series Errata and Revisions. /END OF DOCUMENT/ ESB750ER0910.doc Page 17 of 17

National Grid / Specifications for Electrical Installations / Errata and Revisions ESB 750 Series. TABLE of CONTENTS. TABLE of CONTENTS...

National Grid / Specifications for Electrical Installations / Errata and Revisions ESB 750 Series. TABLE of CONTENTS. TABLE of CONTENTS... SECTION TABLE of CONTENTS PAGE TABLE of CONTENTS... 2 General Notice...3 ESB NO. 750-2010 (VERSION 1.0, 04/20/2010) Specifications for Electrical Installations (Upstate NY, MA, NH, AND RI)...3 New England

More information

SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS Attachment PUC 4-8-5 Page 1 of 26 SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS PRIMARY METER POLE ELECTRIC SYSTEM BULLETIN No. 753 JUNE 1993, 2ND PRINTING APRIL 2002 (Supersedes issue dated

More information

National Grid Requirements for Interconnection of Parallel Generation

National Grid Requirements for Interconnection of Parallel Generation National Grid Requirements for Interconnection of Parallel Generation ESB 756 2017 Revision Review of Changes for RI Jurisdiction, version August 23, 2017 By: National Grid, Retail Connections Policy &

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

SECTION EXTERIOR LIGHTING

SECTION EXTERIOR LIGHTING SECTION 26 56 00 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of exterior luminaries, controls, poles and supports. 1.2 RELATED WORK A. Section 26

More information

Electrical Safety Requirements

Electrical Safety Requirements Electrical Safety Requirements Purpose This document defines the minimum required control measures to reduce the risk of injury or illness related to electricity. Scope Applicable to all Coca-Cola system

More information

PART GENERAL 1.01 SECTION INCLUDES

PART GENERAL 1.01 SECTION INCLUDES Specification Number: 26 24 16.06 Product Name: Emergency Lighting Control NQ Circuit Panelboards: 240 Vac, 48 Vdc Maximum SECTION 26 24 16.06 Emergency Lighting Control NQ Circuit Panelboards: 240 Vac,

More information

National Grid / DG Installation Process Guide per NY SIR / July 2011 ver. 1.0

National Grid / DG Installation Process Guide per NY SIR / July 2011 ver. 1.0 Distributed Generation Installation Process Guide for Connections to National Grid Distribution Facilities per the New York Standardized Interconnection Requirements Introduction National Grid ( The Company

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 83 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-15768N (September 1999) UNIFIED FACILITIES GUIDE

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,

More information

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-26 28 21.00 40 (August 2008) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 28 21.00 40 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete

More information

UFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 28 21.00 40 (August 2014) --------------------------------- Preparing Activity: NASA Superseding UFGS-26 28 21.00 40 (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

NEC 2017 Changes and Their Effect Upon the ICT Industry

NEC 2017 Changes and Their Effect Upon the ICT Industry NEC 2017 Changes and Their Effect Upon the ICT Industry Today s Presenters John Kacperski, RCDD, OSP, CDT Chair of BICSI Standards BICSI Representative on NFPA 70-CMP 16 Richard S. Anderson, RCDD, CDT,

More information

SECTION GENERATOR PARALLELING CONTROLS

SECTION GENERATOR PARALLELING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 23 13 GENERATOR PARALLELING CONTROLS SPEC WRITER NOTE: Delete between // -- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices. SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance

More information

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL This Appendix (2000 IRC Appendix-L) is produced, copyrighted, and maintained by the National Fire Protection Association Association, all rights reserved. Use of this Appendix is pursuant to license with

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications: CONTROLLER CABINETS, POLE MOUNTED - Item No. Special Provision No. 682S27 June 2017 1. SCOPE This Special Provision covers the requirements for the installation of pole mounted controller cabinets and

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ). SECTION 28 13 00 - ACCESS CONTROL PART I - GENERAL 1.1 SUMMARY A. This specification section describes the furnishing, installation, commissioning, and programming of a complete, turnkey, hardwired Andover

More information

National Grid / Supplement to Specifications for Electrical Installations / ESB ver Doc. File: ESB _ver3_

National Grid / Supplement to Specifications for Electrical Installations / ESB ver Doc. File: ESB _ver3_ National Grid / Supplement to Specifications for Electrical Installations / ESB 756-2017 ver. 3.0 Doc. File: ESB756--0617_ver3_0 08-03-2017.docx PREFACE ESB 756-2017 references all requirements for parallel

More information

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS This standard was reviewed and approved by key managers with final approval by an officer of Oncor Electric Delivery on. 1.0 SCOPE 1.1 This guide applies to the interconnection of a Customer with the Company

More information

CONTENTS AUTOMATIC TRANSFER SWITCHES

CONTENTS AUTOMATIC TRANSFER SWITCHES CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training

More information

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41 Dryer User manual DV22K6800** DV22K6800-03650A-00_EN (US)_151211.indd 1 2015-12-11 7:15:41 Before installation Read through the following instructions before installing the dryer, and keep this manual

More information

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System 1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering

More information

Model GPT 3 Freeze Protection Thermostat

Model GPT 3 Freeze Protection Thermostat We manage heat Model GPT 3 Freeze Protection Thermostat Part Number 19425 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202

More information

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -

More information

6. ENGINEERING SYSTEMS REQUIREMENTS H50 WATERFRONT UTILITIES

6. ENGINEERING SYSTEMS REQUIREMENTS H50 WATERFRONT UTILITIES 6. ENGINEERING SYSTEMS REQUIREMENTS H50 WATERFRONT UTILITIES SYSTEMS REQUIREMENTS WATERFRONT UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level

More information

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA PART 1 - GENERAL 1.1 Background SECTION 26 00 10- ELECTRICAL DESIGN CRITERIA A. Brown University maintains it own campus electrical distribution system which serves the majority of the buildings and facilities

More information

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority. Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code

More information

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002 ERRATA TO THE 2000 INTERNATIONAL FIRE CODE Fourth Printing, January 2002 Updated March 29, 2002 Table 2306.2 General Fire Protection and Life Safety Requirements In column 2 (Size of High Piled Storage

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems. SECTION 26 0553 PART 1 GENERAL 1.1 SECTION INCLUDES A. Electrical identification requirements. B. Identification nameplates and labels. C. Wire and cable markers. D. Voltage markers. E. Underground warning

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 It has come to the attention of the electrical authorities having jurisdiction (AHJs) at the DOE sites there is inconsistency

More information

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP TABLE OF CONTENTS 1. Warnings...2 2. Component Match-Up...2 3. Unit Depiction Figures...3 4. Blower Performance Data...5 5. General

More information

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER RV Products Division INSTALLATION INSTRUCTIONS FOR 46413 SERIES PACKAGE AIR CONDITIONER 1. WARNINGS IMPORTANT NOTICE These instructions are for the use of qualified individuals specially trained and experienced

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policy Title: Electrical Safety Work Practice Program Policy Number: UNIV-EHS 430 Policy Approved: January 2014 Policies Superseded: FINA-730 Policy Management Area: Environmental Health and Safety Created/Revision(s):

More information

CHAPTER 20 SERVICE EQUIPMENT

CHAPTER 20 SERVICE EQUIPMENT SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

SECTION SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM

SECTION SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM SECTION 48 14 14 SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES The work of this section consists of furnishing a complete Solar Photovoltaic (PV) Power Generation

More information

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) PART 1 GENERAL 1.01 Scope Furnish and install manual transfer switches (3MTS) with number of poles, amperage, voltage, and withstand

More information

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS This standard was reviewed and approved by key managers on September 6, 2011. Officer approval of this revision is not required. 1.0 SCOPE 1.1 This guide applies to the interconnection of a Utility with

More information

SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION

SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION INTRODUCTION 1. All group-operated switches installed shall be load-break. The interrupters are now included with the plates and no longer need to be itemized as in the past. The identification plates

More information

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER TABLE OF CONTENTS 1. Warnings...................................................... 3 2. Component Match-Up...........................................

More information

CHAPTER 7 ALTERATIONS LEVEL

CHAPTER 7 ALTERATIONS LEVEL CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration

More information

Installation Guide for models:

Installation Guide for models: 140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp

More information

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers BULLETIN 92046 APPLICATION INFORMATION NOVEMBER 2002 SUPERSEDES August 2002 CONTENTS

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

SECTION FIRE-SUPPRESSION STANDPIPES

SECTION FIRE-SUPPRESSION STANDPIPES PART 1 - GENERAL 1.1 DESCRIPTION Fire-suppression wet and manual dry standpipes. 1.2 SCOPE OF WORK SECTION 21 12 00 A. Design, installation and testing shall be in accordance with NFPA 14 except for specified

More information

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC SECTION 23 09 00 (15900) - INSTRUMENTATION AND CONTROL FOR HVAC PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Control Panels 2. Thermostats 3. Actuators 4. Dampers 5. Wiring B. Related Sections:

More information

Electrical Design Guidelines Table of Contents

Electrical Design Guidelines Table of Contents C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6

More information

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures PART 1 GENERAL 1.1 WORK INCLUDED Section 27 11 00 COMMUNICATION EQUIPMENT ROOM FITTINGS Section 27 11 16 Communications Cabinets, Racks, Frames and Enclosures A. Provide all labor, materials, and equipment

More information

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP RV Products Division INSTALLATION INSTRUCTIONS FOR 46515 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP TABLE OF CONTENTS 1. Warnings.................................................. 2 2. Component

More information

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION CHAPTER 23.45 Sections LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION 23.45.100 Local amendments to the International Fire Code, 2006 Edition... 2 23.45.102.1 Construction and design provisions...

More information

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS LOW-INTENSITY INFRARED HEATING SYSTEMS Omega II Pre Engineered Packages Products by: COMBUSTION SUBMITTAL DATA PROJECT: Specifications for Omega II UNITARY P.E.P. SYSTEMS PART 1 - GENERAL It is the intent

More information

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015 NEC Requirements for Standby Power Systems New England Building Officials Education Association Annual Conference October 5, 2015 Emergency & Standby Power Systems Alternative power sources are utilized

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 2017-08-031 AN ORDINANCE OF THE CITY OF LANCASTER, TEXAS, REPEALING THE NATIONAL ELECTRICAL CODE 2014 EDITION IN ITS ENTIRETY AND REPLACING IT WITH THE ADOPTION OF THE NATIONAL ELECTRICAL

More information

PowerWave 2 Busway System

PowerWave 2 Busway System PowerWave 2 Busway System Guide Specifications (Revision 004, 11/17/2017) 1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening,

More information

FLCH4R Garage and Utility Electric Heater

FLCH4R Garage and Utility Electric Heater FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Model No. Volts Amps Watts BTU/HR Phase High Low High Low High Low Min Fuse Size* FLCH4R 208 17.3 8.66 3600

More information

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low voltage power panelboards 1.02 RELATED SECTIONS 1.03 REFERENCES

More information

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual MANUAL We manage heat Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 http://www.networketi.com/

More information

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS

More information

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS

More information

Guide Specification Model CTG Automatic Transfer Switch

Guide Specification Model CTG Automatic Transfer Switch Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production

More information

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5

More information

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. U.S.A. WARNING FOR YOUR

More information

Series. Access Power Controllers. Installation Guide

Series. Access Power Controllers. Installation Guide Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse

More information

NFPA Changes

NFPA Changes Chapter 27, Public Fire Emergency Alarm Reporting Systems Summary. Chapter 27 was Chapter 9 in NFPA 72-2007. The word fire is replaced by the word emergency. The term public fire service communications

More information

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE - SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN VC3ED ML-137013 - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly

More information

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................

More information

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows: Technical Bulletin #18-002 February 2018 / 2017 OFC Mobile Food Units Referenced Codes and Standards: OAC 1301:7-7-3(T); OFC 320 OAC 1301:7-7-2(B); OFC 202 OAC 1301:7-7-9(F); OFC 906 NFPA 58 (2014) NFPA

More information

SECTION ELECTRICAL GENERAL PROVISIONS

SECTION ELECTRICAL GENERAL PROVISIONS PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling

More information

BUILT IN UNIT INSTRUCTION GUIDE

BUILT IN UNIT INSTRUCTION GUIDE APPLY SERIAL NUMBER LABEL FROM CARTON Serial No. XXXXXX000000 MODEL NO. BUILT IN UNIT INSTRUCTION GUIDE Please use this manual in conjunction with your main manual to properly assemble your built-in grill.

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET

MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET LIGHTING SERVICE CABINET TYPE: L1 & L2 02/02 /2012 Page 1 of 21 SPECIFICATIONS FOR L1 & L2 LIGHTING SERVICE CABINETS Table of Contents 1. General

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The demolition

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL RELEASE DEVICES MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL The LiftMaster Fire Control (LM21-AFC) Release Device/Control Panel is UL/CUL listed normally energized fail-safe device incorporating

More information

INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30" MODELS: SGS304, SGSX304 36" MODELS: SGS365, SGSX365 45" MODELS: SGS456, SGSX456

INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30 MODELS: SGS304, SGSX304 36 MODELS: SGS365, SGSX365 45 MODELS: SGS456, SGSX456 INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30" MODELS: SGS304, SGSX304 36" MODELS: SGS365, SGSX365 45" MODELS: SGS456, SGSX456 PLEASE READ INSTRUCTION BEFORE PROCEEDING IMPORTANT: INSTALLER:

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-28 31 75.00 10 (November 2008) ----------------------------------- Preparing Activity: USACE Superseding UFGS-28 31 75.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting

More information

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION WARNING 1. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus ADDENDUM FORM INVITATION TO TENDER: 2016-067 ADDENDUM NO: 1 DATE ISSUED: June 23, 2016 ISSUED BY: Monty Thibeault DESCRIPTION: Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

More information

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES SECTION 238313 - RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES A. Low-voltage Electric Snow and ice heating elements "under" finished roof materials (shingles or metal), gutters,

More information

AUTOMATIC DRYER INSTALLATION INSTRUCTIONS MISE EN SERVICE SÉCHEUSE AUTOMATIQUE INSTRUCCIONES DE INSTALACIÓN DE LA SECADORA AUTOMÁTICA

AUTOMATIC DRYER INSTALLATION INSTRUCTIONS MISE EN SERVICE SÉCHEUSE AUTOMATIQUE INSTRUCCIONES DE INSTALACIÓN DE LA SECADORA AUTOMÁTICA AUTOMATIC DRYER INSTALLATION INSTRUCTIONS MISE EN SERVICE SÉCHEUSE AUTOMATIQUE INSTRUCCIONES DE INSTALACIÓN DE LA SECADORA AUTOMÁTICA The installation, including a proper exhaust system, is the responsibility

More information

Page 1 of General

Page 1 of General Page 1 of 8 16.1 General 1. This section covers items common to sections of CSI s Master Format - Division 16. 2. Dalhousie University is certified by IBEW for new construction and all electrical contractors

More information

A. Section Instrumentation and Control Devices for HVAC. B. Section Building Automation Systems(BAS) for HVAC

A. Section Instrumentation and Control Devices for HVAC. B. Section Building Automation Systems(BAS) for HVAC SECTION 23 09 43 - PNEUMATIC CONTROLS FOR HVAC PART I - GENERAL 1.1 SECTION INCLUDES A. Control Air Compressor Units. B. Control Devices, Components, Piping and Material. C. Instructions for Owners. 1.2

More information

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings Building Standards Advisory Promoting construction of safe, healthy, habitable buildings Saskatchewan Amendments to the National Building Code 2015 In Canada, provincial and territorial governments have

More information

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev. Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Units Accessibility s rev. 11/12/12 Unit 2005 CT State Building Code () A117.1 (2003) **indicates CT Amendment to

More information