2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.
|
|
- Arthur Chapman
- 6 years ago
- Views:
Transcription
1 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. info@cristalcontrols.com cristalcontrols.com TM
2 Index Quick Selection Which Technology to use...4 Retrofit Ceiling Occupancy Sensor...5 Low Voltage Ceiling Occupancy Sensor...10 Line Voltage Ceiling Occupancy Sensor...16 Line Voltage Ceiling Occupancy Sensor, 347VAC Retrofit Wall Switch Occupancy Sensor...27 Low Voltage Wall Switch Occupancy Sensor Low Voltage Wall Mount Occupancy Sensor Line Voltage Wall Switch Occupancy Sensor Line Voltage Wall Switch Occupancy Sensor, 347V Pole Power Pack ( ) Pole Power Pack (347-1) Pole Power Pack ( ) Sensor Settings Warranty Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com
3 Quick Selection Chart CCORSDD1-N-N (Retrofit Applications Only) CEILING LOW VOLTAGE Ceiling Recessed, Std Lens, Dual Tech, 24V, 1P 3 CCORSDD1-R-N Ceiling Recessed, Std Lens, Dual, 24V, 1P, Rly 3 CCORSDD2-N-N Ceiling Recessed, Std Lens, Dual Tech, 24V, 2 Pole 8 CCORSDD2-R-N Ceiling Recessed, Std Lens,Dual Tech, 24V, 2 Pole, Rly 8 CCORXDD2-PR-N Ceiling Recessed, Ext Lens, Dual Tech, 24V, 2P, Ph, Rly 8 CCORSDD2-DPR-L Ceiling Rec, Std Lens, Dual Tech, 24V, 2P, Dim, Ph, Rly, LT 8 CCORXDD2-DPR-L Ceiling Rec, Ext Lens, Dual Tech, 24V, 2P, Dim, Ph, Rly, LT 8 PAGE CEILING LINE VOLTAGE PAGE CCORBIU2-P-N Ceiling Recessed, High Bay, PIR, 120/277, 2P, Photo 14 CCORSDU1-P-N Ceiling Recessed, Std Lens,Dual Tech, 120/277, 1P, Photo 14 CCORSDU2-P-N Ceiling Recessed, Std Lens, Dual Tech, 120/277, 2P, Photo 14 CCORXDU2-P-L Ceiling Recessed, Ext. Lens, Dual Tech, 120/277, 2P, Photo 14 CCORSD31-P-N Ceiling Recessed, Std Lens, Dual Tech, 347, 1P, Photo 20 CCORSD32-P-N Ceiling Recessed, Std Lens, Dual Tech, 347, 2P, Photo 20 CCORXD32-P-N Ceiling Recessed, Ext. Lens, Dual Tech, 347, 2P, Photo 20 CCOSSDD1-P-VW (Retrofit Applications Only) WALL SWITCHES LOW VOLTAGE Switch Mt Sensor, Dual Tech, 24V, 1P, Photo, Vandal, White 25 CCOSSDD2-P-VW Switch Mt Sensor, Dual Tech, 24V, 2P, Photo, Vandal, White 30 CCOSSDD2-DPR-VW Switch Mt Sensor, Dual Tech, 24V, 2P, Dim, Ph, Rly, Vandal, W 30 PAGE WALL MOUNT (Corner, aisles etc ) PAGE CCOWCDD2-R-N Wall Mount Sensor, Corner Lens, Dual Tech, 24V, 2P, Rly 36 CCOWLDD2-R-N Wall Mount Sensor, Large Area Lens, Dual Tech, 24V, 2P, Rly 36 CCOWCDD2-DPR-N Wall Mt Sensor, Corner Lens, Dual Tech, 24V, 2P, Dim, Ph, Rly 36 3
4 Quick Selection Chart & Which Technology to use WALL SWITCHES LINE VOLTAGE PAGE CCOSSDU1-P-VW Switch Mt Sensor, Dual Tech, 120/277, 1P, Photo, Vandal, White 41 CCOSSDU2-P-VW Switch Mt Sensor, Dual Tech, 120/277, 2P, Photo, Vandal, White 41 CCVSSDU2-P-VW Switch Mt Vac. Sensor, Dual Tech, 120/277, 2P, Photo, Vandal, White 41 CCOSSD31-P-VW Switch Mt Sensor, Dual Tech, 347, 1P, Photo, Vandal, White 46 CCOSSD32-P-VW Switch Mt Sensor, Dual Techl, 347, 2P, Photo, Vandal, White 46 POWER PACK PAGE CCP-PP20-D Power Pack, 120/277, 20A, 1P, 24VAC power, Diode Pulse 51 CCP-PP20-2P Power Pack, 120/277, 20A, 2P, 24VAC power, Diode Pulse 54 CCP-PP D Power Pack, 347, 20A, 1P, 24VAC power, Diode Pulse 57 CCIR-3110 PROGRAMMER IR Handheld Remote Programmer Ceiling Sensor Wall Switch Wall Sensor LOCATION PASSIVE INFRARED PIR UNTRASONIC DUAL TECHNOLOGY SENSOR TYPE % SAVINGS Bedroom X 1 2 Cafeteria X Classroom X X 2 40 Closet/Storage X X Conference Room X X Hallway X 2 3 Lecture Hall X 2 Library X 2 Lobby X Private Office X X X Rest Room Multi Stall X X Warehouse X
5 Retrofit Ceiling Occupancy Sensor Technical Data Part No CCORSDD1-N-N CCORXDD1-N-N Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOR Séries of sensors are designed to mount recessed on a ceilings giving a 360 coverage pattern. The low voltage edition of this sensor gives the capability of operating and controlling the CCP-PP20-D Power Pack and/or diode pulse relays. Specification Inputs 24 VAC +/- 25% Class 2 Low Voltage Source 60 Hz Use #18AWG wire Outputs Diode Pulse : Each output is capable of driving one Diode Pulse Relay Power consumption 9,5 ma Standard Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Features Recessed ceiling mounted occupancy sensor provides 360 coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com Operation Low voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADI-Voice is then activated to work alongside the PIR to detect occupancy. cristalcontrols.com 5
6 Retrofit Ceiling Occupancy Sensor Technical Data & Details Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8 or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Trickle Current sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections Wiring to a Power Pack Wiring to a Relay Panel Sensor Settings (See page for Sensor Setting description) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Vacancy Sensor 4. Smart Sensing 5. Automatic Timeout 6
7 Retrofit Ceiling Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Standard Lens) f Locate the sensor near the entrance door wall to prevent it from viewing out into the hallway. f The lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. f Positioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy 7
8 Retrofit Ceiling Occupancy Sensor Details & Coverage Extended Lens (X) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Installing in Larger Room (Extended Lens) f Place the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A & B) or in dead center of room. f Tilt the lens to ai m the detection zone to the bottom of the door. (C) f Positioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. * Application and Performance Specification Information Subject to Change without Notification 8
9 Retrofit Ceiling Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8 deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. Wiring The WOR Series Retrofit sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. White 24 Vac Bleu DO NOt USE Red Primary output pole Red/White Not Used Orange Not Used Yellow/Black Not Used Yellow Not Used Yellow/White Not Used Violet(+) Not Used Grey (-) Not Used DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOR*DD1-N-N DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Not Used N/A N/A OFF 6 Not Used N/A N/A OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 9
10 Low Voltage Ceiling Occupancy Sensor Technical Data Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60Hz Use #18WG wire Part No CCORSDD2-N-N CCORSDD2-R-N CCORSDD2-DPR-L CCORXDD2-PR-N CCORXDD2-DPR-L Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOR Series of sensors are designed to mount recessed in to a ceiling space providing a 360 coverage pattern. The low voltage edition of this sensor gives the capability of operating and controlling the CCPPP20-D Power Pack and/or diode pulse relays. Outputs Diode Pulse : Each output is capable of driving up to four Diode Pulse relays. 0-10V Dimming : Use to control up to 50 Ballasts. Connections are polarity sensitive. LED drivers can connect up to 25mA Aux Relay : SPDT Form-C contact rated for 1A at 30VDC Power consumption 9.5 ma Standard 14.0 ma with Auxiliary Relay Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40 C/F Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com Features Recessed ceiling mounted occupancy sensor provides 360 coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. The photo sensor option is available to provide a 0-10VDC dimming ballast/led* Drivers output for Daylight Harvesting. * LED drivers up to 25mA, please contact driver manufacturer for currents Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. cristalcontrols.com 10
11 Low Voltage Ceiling Occupancy Sensor Technical Data & Details Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8 or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Line Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 11
12 Low Voltage Ceiling Occupancy Sensor Technical Data & Details Sensor Settings (See page for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 7. Daylight Harvest Dimming (0-10V Output) (-D) 8. Multi-Level Switching (2-Pole w/o Photo Sensing option) 9. Multi-Level Photo Sensing (2-Pole w/ Photo Option) 10. Sensor Link 12
13 Low Voltage Ceiling Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Standard Lens) f Locate the sensor near the entrance door wall to prevent it from viewing out into the hallway. f The lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. f Positioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Extended Lens (X) f Optimal usage is to detect small motions such as walking f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy 13
14 Low Voltage Ceiling Occupancy Sensor Details & Coverage Installing in Larger Room (Extended Lens) f Place the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A & B) or in dead center of room. f Tilt the lens to aim the detection zone to the bottom of the door. (C) f Positioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8 deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. Wiring The CCOR Series Low Voltage sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. 14
15 Low Voltage Ceiling Occupancy Sensor Installation DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOR N - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Not Used N/A N/A OFF 6 Not Used N/A N/A OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON CCOR P - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON CCOR DPR - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Photocell Inhibit** Photocell Disabled & Fixed Dim Level Photocell Enabled + Auto Dim Level 6 Photocell Control* Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON OFF 15
16 Line Voltage Ceiling Occupancy Sensor Technical Data Specification Power 120/277 VAC 60Hz Part No CCORBIU2-P-N PIR Only CCORSDU1-P-N CCORSDU2-P-N CCORXDU2-P-L Desription The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. Contact Ratings 120 VAC-800W 277 VAC-1200W Power consumption 5,7 ma Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com The CCOR Series of sensors are designed to mount recessed in to a ceiling space providing a 360 coverage pattern. Has an adjustable tilting lens to prevent detection outside monitored space. Features Recessed ceiling mounted occupancy sensor provides 360 coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. Ambient Operating Temperature : 32 F to 104 F (0 C to 40 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40 C/F. Indoor use only. cristalcontrols.com 16
17 Line Voltage Ceiling Occupancy Sensor Technical Data & Details Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8 or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOR**U*-*-* CCOR**U2*-*-* Sensor Settings (See page for Sensor Setting description) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Photo Sensing (-P) 6. Multi-Level Photo Sensing (2-Pole w/ Photo Option) 17
18 Line Voltage Ceiling Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Standard Lens) f Locate the sensor near the entrance door wall to prevent it from viewing out into the hallway. f The lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. f Positioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Extended Lens (X) f Optimal usage is to detect small motions such as walking f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy 18
19 Line Voltage Ceiling Occupancy Sensor Details & Coverage Hi-Bay Lens (B) f Optimal usage is to detect small motions such as walking f Designed for a mounting height up to 40Ft f PIR only Installing in Larger Room (Extended Lens) f Place the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A & B) or in dead center of room. f Tilt the lens to ai m the detection zone to the bottom of the door. (C) f Positioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. * Application and Performance Specification Information Subject to Change without Notification 19
20 Line Voltage Ceiling Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8 deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOR Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOR**U*-*-* CCOR**U2*-*-* 20
21 Line Voltage Ceiling Occupancy Sensor Installation DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOR N - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Not Used N/A N/A OFF 6 Not Used N/A N/A OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON CCOR P - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Not Used Disabled Enabled OFF 6* Not Used Inhibit 2 nd Pole Only Inhibit Both Pole OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON *Available in 2-Pole models (-2) only 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 21
22 Line Voltage Ceiling Occupancy Sensor, 347VAC Technical Data Specification Power VAC 60Hz Part No CCORSD31-P-N CCORXD32-P-N CCORSD32-P-N Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOR Series of sensors are designed to mount recessed in to a ceiling space providing a 360 coverage pattern. Has an adjustable tilting lens to prevent detection outside monitored space. Contact Ratings 347 VAC-1200W Power consumption 5,7 ma Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 32 F to 104 F (0 C to 40 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40 C/F. Indoor use only. Features Recessed ceiling mounted occupancy sensor provides 360 coverage using an adjustable swivel head to optimize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use both Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. 22
23 Line Voltage Ceiling Occupancy Sensor, 347VAC Technical Data & Details Dimensions & Mounting Unit attaches to mounting ring with screws or it can be mounted into an octagon box. The CCOR sensor will fit an octagon box. It is very important that conduits be attached at opposite ends of the box. Use a 2-1/8 or more, deep box. If the box is less, use the spacer ring. Wiring Instructions The CCOR Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOR**3*-*-* CCOR**32*-*-* Sensor Settings (See page for Sensor Setting description) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Photo Sensing (-P) 6. Multi-Level Photo Sensing (2-Pole w/ Photo Option) 23
24 Line Voltage Ceiling Occupancy Sensor, 347VAC Details & Coverage Installation Installing in Smaller Room (Standard Lens) f Locate the sensor near the entrance door wall to prevent it from viewing out into the hallway. f The lens can rotate, allowing the sensor to be pointed toward the area in front of the entrance door. f Positioning the sensor in this manner ensures that an occupant moves across the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Installing in a Larger Room (Extended Lens) f Place the sensor near the center of the room ceiling. Locate it so the approximate distance of 27ft in and over (A&B) or in dead center of room. f Tilt the lens to aim the detection zone of the bottom of the door (C). f Positioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. 24
25 Line Voltage Ceiling Occupancy Sensor, 347VAC Details & Coverage Extended Lens (X) f Optimal usage is to detect small motions such as walking f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Hi-Bay Lens (B) f Optimal usage is to detect small motions such as walking f Designed for a mounting height up to 40Ft f PIR only 25
26 Line Voltage Ceiling Occupancy Sensor, 347VAC Installation Installation & Wiring Directions Installation Mounting of the device requires a 2-1/8 deep or more, octagonal junction box. Install by recessing the device into the octagon box; lining up the mounting holes and securing it using the screws provided. If too shallow, use the spacer ring is provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOR Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOR**3*-*-* CCOR**32*-*-* 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOR P - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5 Photocell Inhibit** Disabled Enabled OFF 6 Photocell Control Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON *Available in 2-Pole models (-2) only cristalcontrols.com 26
27 Retrofit Wall Switch Occupancy Sensor Technical Data Part No CCOSSDD1-P-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180 coverage pattern The low voltage edition of this sensor gives the capability of operating and controlling the CCP-PP20-D Power Pack and/or diode pulse relays. Direct replacement for WR Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60Hz Use #18WG wire Outputs Diode Pulse : Each output is capable of driving up to one Diode Pulse relays. Power consumption 9.5 ma Standard Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40 C/F. Features Wall Switch occupancy sensor provides 180 coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. cristalcontrols.com 27
28 Retrofit Wall Switch Occupancy Sensor Technical Data & Details Operation Line voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC tranformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADI- Voice is then activated to work alongside the PIR to detect occupancy. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Low Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 28
29 Retrofit Wall Switch Occupancy Sensor Details Sensors Settings (See page for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 29
30 Retrofit Wall Switch Occupancy Sensor Details & Coverage Installation Mount the CCOSSDD1-P-VW sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices f Sensor effective in obstructed spaces f ADI-Voice re-activation and Smart Sense prevents lights out condition Typical Office Installing in Washrooms f Sensor effective in partitioned spaces f ADI-Voice re-activation and Smart Sense prevents lignts out condition Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 7-15ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View Typical WashRooms *Application and Performance Specification Information Subject to Change without Notification 30
31 Retrofit Wall Switch Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a standard box. Install by recessing the device into the standard gang box; lining up the mounting hole and securing it using the screws provided. Wiring The CCOSSDD1-P-VW Retrofit sensors are equipped with plug-in harness for easy installation. This hardness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOSSDD1-P-VW DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OFF 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 31
32 Low Voltage Wall Switch Occupancy Sensor Technical Data 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T *Plate not included Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60 Hz Use #18AWG wire Part No CCOSSDD2-P-VW CCOSSDD2-DPR-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180 coverage pattern. The low voltage edition of this sensor gives the capability of operating and controlling the WP- PP20-D Power Pack and/or diode pulse relays. Outputs Diode Pulse: Each output is capable of driving up to four Diode Pulse relays. 0-10V Dimming: Use to control up to 50 Ballasts, or 25mA sync of LED driver. Connections are polarity sensitive. Aux Relay: SPDT Form-C contact rated for 1A at 30VDC Power consumption 9.5 ma Standard 14.0 ma with Auxiliary Relay Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40 C/F. Features Wall Switch occupancy sensor provides 180 coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. The photo sensor option is available to provide a 0-10VDC dimming ballast or 25mA sync for LED drivers output for Daylight Harvesting. F info@cristalcontrols.com Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning. cristalcontrols.com 32
33 Low Voltage Wall Switch Occupancy Sensor Technical Data & Details Operation Low voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADI- Voice is then activated to work alongside the PIR to detect occupancy. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Low Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 33
34 Low Voltage Wall Switch Occupancy Sensor Details Sensors Settings (See page for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 7. Daylight Harvest Dimming (0-10V Output) (-D) 8. Multi-Level Switching (2-Pole w/o Photo Option) 9. Multi-Level Photo Sensing (2-Pole w/photo Option) 10. Sensor Link 34
35 Low Voltage Wall Switch Occupancy Sensor Details and Coverage Installation Mount the CCOS Series sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices f Sensor effective in obstructed spaces f ADI-Voice re-activation and Smart Sense prevents lights out condition Typical Office Installing in Washrooms f Sensor effective in partitioned spaces f ADI-Voice re-activation and Smart Sense prevents lights out condition Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 4ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View Typical WashRooms 35
36 Low Voltage Wall Switch Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a standard gang box. Install by recessing the device into the standard gang box; lining up the mounting holes and securing it using the screws provided. Wiring The CCOS Series Low Voltage sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOS P - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OFF 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON 36
37 Low Voltage Wall Switch Occupancy Sensor Installation DIP Switches CCOS DPR - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OF 5* Photocell Inhibit** Photocell Disabled & Fixed Din Level Photocell Enabled & Auto Dim Level 6* Photocell Control Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON OFF 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 37
38 Low Voltage Wall Mount Occupancy Sensor Technical Data Part No CCOWCDD2-R-N CCOWLDD2-R-N CCOWCDD2-DPR-N Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOW Series of sensors are designed to surface mount on a wall giving either a 90 or 130 coverage pattern. Specification Inputs 24 VAC +/-25% Class 2 Low Voltage Source 60 Hz Use #18AWG wire The low voltage edition of this sensor gives the capability of operating and controlling the WP-PP20-D Power Pack and/or diode pulse relays Lavoisier, #135 Quebec, Quebec G1N 4L6 T F Outputs Diode Pulse: Each output is capable of driving up to four Diode Pulse relays. 0-10V Dimming: Use to control up to 50 Ballasts, or 25mA sync of LED driver. Aux Relay: SPDT Form-C contact rated for 1A at 30VDC Power consumption 9.5 ma Standard 14.0 ma with Auxiliary Relay Approvals FCC Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Features Wall mount occupancy sensor provides 90 or 130 coverage. Has the ability to rotate in both the horizontal and vertical axis to optimize the sensing area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. The photo sensor option is available to provide a 0-10VDC dimming ballast or 25mA sync for LED drivers output for Daylight Harvesting. info@cristalcontrols.com Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during cristalcontrols.com commissioning. 38
39 Low Voltage Wall Mount Occupancy Sensor Technical Data & Details Operation Low voltage sensors are powered by 24VAC from either the CCP-PP20-D Power Pack or a 24VAC transformer. When in operation, the sensor will detect initial motion using PIR; once motion is detected the internal contact will close. The ADI- Voice is then activated to work alongside the PIR to detect occupancy. Dimensions & Mounting Mount in a octagon box. Wall Mount Ceiling Mount Wiring Instructions The CCOW Series Low Voltage sensors are equipped with #22 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCP-PP20-D 39
40 Low Voltage Wall Mount Occupancy Sensor Details Sensors Settings (See page for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 5. Vacancy Sensor 6. Photo Sensing (-P) 7. Daylight Harvest Dimming (0-10V Output) (-D) 8. Multi-Level Switching (2-Pole w/o Photo Option) 9. Multi-Level Photo Sensing (2-Pole w/photo Option) 10. Sensor Link 40
41 Low Voltage Wall Mount Occupancy Sensor Details & Coverage Installation Installing in Smaller Room (Corner Lens) f Locate the sensor in the corner, along the entrance door to prevent it from viewing out into the hallway. f The sensor can be rotated, allowing it to be pointed along the entrance door and slighly downwards. f Positioning the sensor in this manner ensures that an occupant move accross the longest detection beam upon entrance, utilizing the sensor's maximum PIR range. Typical Enclosed Office Corner Lens f Optimal usage is to detect small motions such as hand movements. f Designed for a mounting height of up to 7-15ft. f ADI-Voice can detect around corners that PIR cannot to maintain occupancy. Installing in Larger Room (Large Area Lens) f Place the sensor near the center of the wall that is adjacent to the entrance. f The sensor can be rotated, allowing it to be pointed along the entrance door and slighly downwards. f Positioning the sensor in this manner ensures that the beam does not reach outside the room without reducing sensitivity. Typical Classroom Large Area Lens f Optimal usage is to detect large motions such as walking. f Designed for a mounting height of 7-15ft. f ADI-Voice can detect around corners that PIR cannot to maintain occupancy. 41
42 Low Voltage Wall Mount Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a 2 1/8" deep, octogonal junction box. Install by recessing the device into the o ctogonal box; lining up the mounting holes and securing it using the screws provided. Wiring The CCOW Series Low Voltage sensors are equipped with plug-in harness for easy installation. This harness has #20 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOW R-N DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) OFF 5 Not Used N/A N/A OFF 6 Not Used N/A N/A OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 42
43 Line Voltage Wall Switch Occupancy Sensor Technical Data Part No CCOSSDU1-P-VW CCOSSDU2-P-VW CCVSSDU2-P-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180 coverage pattern *Plate not included Specification Power 120/277 VAC 60Hz Contact Ratings 120 VAC - 800W 277 VAC W Power consumption 400 ma Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 32 F to 104 F (0 C to 40 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Features Wall Switch occupancy sensor provides 180 coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 43
44 Line Voltage Wall Switch Occupancy Sensor Technical Data & Details Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOS**U*-*-* CCOS**U2*-*-* 44
45 Line Voltage Wall Switch Occupancy Sensor Details Sensors Settings (See page for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 6. Photo Sensing (-P) 9. Multi-Level Photo Sensing (2-Pole w/photo Option) 45
46 Line Voltage Wall Switch Occupancy Sensor Details & Coverage Installation Mount the CCOS Series sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices f Sensor effective in obstructed spaces f ADI-Voice re-activation and Smart Sense prevents lights out condition Typical Office Installing in Washrooms f Sensor effective in partitioned spaces f ADI-Voice re-activation and Smart Sense prevents lignts out condition Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 4ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View Typical WashRooms 46
47 Line Voltage Wall Switch Occupancy Sensor Installation Installation & Wiring Directions Installation Mounting of the device requires a standard gang box. Install by recessing the device into the standard gang box; lining up the mounting holes and securing it using the screws provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOS Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOS**U*-*-* CCOS**U2*-*-* 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOS P - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON *Available in 2-Pole models (-2) only cristalcontrols.com 47
48 Line Voltage Wall Switch Occupancy Sensor, 347V Technical Data Part No CCOSSD31-P-VW CCOSSD32-P-VW Description The Diversa occupancy sensors use PIR and ADI-Voice technologies to determine the presence of people and perform the control actions when occupancy (or vacancy) is detected. The CCOS Series of sensors are designed replace a low voltage wall switch giving a 180 coverage pattern. 347 VAC. *Plate not included Specification Power 347 VAC 60Hz Contact Ratings 347 VAC W Power consumption 400 ma Approvals Certified to UL 508, UL244A, CSA C22.2 #14 Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 32 F to 104 F (0 C to 40 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) Low temp and high humidity option [-L] products: PCB conformal coated for resistance to damp environments and operation to -40 C/F. Indoor use only. Features Wall Switch occupancy sensor provides 180 coverage to maximize the sensor area. The dual-tech sensor utilizes ADI-Voice Technology, which has advanced digital signal processing for accurate detection of human speech. A Self-adapting mode can be set to use Passive Infrared (PIR) & Accurate Detection Intelligence (ADI) Voice technologies to automatically track occupancy tendencies for continuous maximizing of energy savings. Smart Sensing allows for an immediate return to occupied mode in the event of a false off being triggered. Can be programmed by on-board DIP switches and dials or an IR Setting Unit for added convenience, especially during commissioning Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 48
49 Line Voltage Wall Switch Occupancy Sensor, 347V Technical Data & Details Operation Line voltage sensors draw control power directly from the lighting circuit they are intended to control. When in operation the sensor will detect initial motion using PIR; once motion is detected, the internal contact will close. ADI-Voice is then activated to work alongside PIR to maintain the occupied condition as long as people are within the sensing range. Dimensions & Mounting Mount in a standard gang box. Wiring Instructions The CCOS Series Line Voltage sensors are equipped with #14 AWG leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. Electrical Connections CCOSSD3*-*-* CCOSSD32*-*-* 49
50 Line Voltage Wall Switch Occupancy Sensor, 347V Details Sensors Settings (See page for Sensor Setting description item) 1. Programming - IR / Manual Setting 2. Detection (Dual or PIR Only) 3. Automatic Timeout 4. Smart Sensing 6. Photo Sensing (-P) 9. Multi-Level Photo Sensing (2-Pole w/photo Option) 50
51 Line Voltage Wall Switch Occupancy Sensor, 347V Details & Coverage Installation Mount the CCOS Series sensor on the wall about 4' above floor level near the midline of the room so its PIR detection zones cover the room area and any obstructions are within range of the ADI-Voice detector. There should be no obstructions between the sensor and the room entrance. The ensures that the sensor's PIR lens will be activated when a person enters the room, wich will subsequently trigger the ADI-Voice. Installing in Offices f Sensor effective in obstructed spaces f Voice sound re-activation prevents lights out condition Typical Office Installing in Washrooms f Sensor effective in partitioned spaces f Voice sound re-activation prevents lignts out condition Standard Lens (S) f Optimal usage is to detect small motions such as hand movements f Designed for a mounting height of 4ft f ADI-Voice can detect around corners that PIR cannot to maintain occupancy Top View Side View Typical WashRooms 51
52 Line Voltage Wall Switch Occupancy Sensor, 347V Installation Installation & Wiring Directions Installation Mounting of the device requires a standard gang box. Install by recessing the device into the standard gang box; lining up the mounting holes and securing it using the screws provided. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The CCOS Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wirenuts to connect the wires to the incoming load terminations; for installation with fieldinstalled conductors of 60ºC minimum rating. CCOSSD3*-*-* CCOSSD32*-*-* 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com DIP Switches A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor. CCOS P - DIP # Function On Off Default 1 Voice Detection Disabled Enabled OFF 2 Motion Detection Sensivity High Normal OFF 3 Detection LED Disabled Enabled OFF 4 Auto or Manual ON Occupancy (Auto-ON) Vacancy (Manual ON) ON 5* Photocell Inhibit** Disabled Enabled OFF 6* Photocell Control Inhibit 2 nd Pole Only Inhibit Both Poles OFF 7 Manual Override Button Disabled Enabled OFF 8 Settings Input IR Handheld (CCIR-3110) Manual Dips/Dials ON *Available in 2-Pole models (-2) only cristalcontrols.com 52
53 1-Pole Power Pack ( ) Technical Data Part No CCP-PP20-D 1-Pole 120/277VAC Features Designed for use with Diversa occupancy sensors and Diode Pulse relays. Single pole 120/277 VAC Specification Load Voltage 120/277 VAC 60 Hz Switched Load 120/277 VAC See Table for contact rating Use #14 AWG Wire Inputs Diode Pulse #14AWG wire Secondary Power Source 24 VAC, 150 ma #14AWG wire Approvals Certified to CAN/CSA Std. C22.2 No. 14 Conforms to UL 508 Standard Title 24 FCC Plenum Rated Class 2 Rating Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 53
54 1-Pole Power Pack ( ) Technical Data & Details Operation The CCP-PP20-D Power Pack work in conjunction with the Diversa Low Voltage Sensors by providing power to the sensors and receiving on/off commands from the sensor. Contact Load Rating Voltage General Tungsten Standard Ballast Electronic Ballast 120V 20A 20A 20A 16A 277V 20A 20A 20A 16A All Power Packs provide a 24 VAC secondary source for use with the Low Voltage Diversa Sensors and other Diode Pulse devices. All switches or loads required to be supported by the sensor must be included in the loading capacity of the Power Pack. Wiring Directions Voltage Maximum Load Per Input Max# of linked sensors 24VAC 12 Typical Low Voltage Loads Device Part# Current (ma) Ceiling Mounted Sensor Wall Switch Sensor Wall Mount Sensor CCOR/CCVR CCOS/CCVS CCOW/CCVW 9,5mA Standard 14,0mA w/aux Relay Diode Pulse Switch WR mA Wiring Terminating wire shall be a minimum of #22 AWG for control power connections and shall be suitably sized to handle the load ratings below. Electrical Connections CCP-PP20-D 54
55 1-Pole Power Pack ( ) Details Dimensions & Mounting The power pack shall be mounted inside an electrical junction box or panel with a ½ threaded nipple. CCP-PP20-D * Application and Performance Specification Information Subject to Change without Notification 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 55
56 1-Pole Power Pack (347-1) Technical Data Part No CCP-PP D 1-Pole VAC Features Designed for use with Diversa occupancy sensors and Diode Pulse relays. Single pole 347 VAC Specification Load Voltage 347 VAC 60 Hz Switched Load 347 VAC See Table for contact rating Use #14 AWG Wire Inputs Diode Pulse #14AWG wire Secondary Power Source 24 VAC, 150 ma #14AWG wire Approvals Certified to CAN/CSA Std. C22.2 No. 14 Conforms to UL 508 Standard Title 24 FCC Plenum Rated Class 2 Rating Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 56
57 1-Pole Power Pack (347-1) Technical Data & Details Operation The CCP-PP D Power Pack work in conjunction with the Diversa Low Voltage Sensors by providing power to the sensors and receiving on/off commands from the sensor. Contact Load Rating Voltage General Tungsten Standard Ballast Electronic Ballast 347V 20A 20A 20A 16A All Power Packs provide a 24 VAC secondary source for use with the Low Voltage Diversa Sensors and other Diode Pulse devices. All switches or loads required to be supported by the sensor must be included in the loading capacity of the Power Pack. Voltage Maximum Load Per Input Max# of linked sensors 24VAC 12 Typical Low Voltage Loads Device Part# Current (ma) Ceiling Mounted Sensor Wall Switch Sensor Wall Mount Sensor CCOR/CCVR CCOS/CCVS CCOW/CCVW 9,5mA Standard 14,0mA w/aux Relay Diode Pulse Switch WR mA Installation & Wiring Directions Installation The power pack shall be mounted inside an electrical junction box or panel with a ½ threaded nipple. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The power packs are equipped with #14 AWG stranded leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. For installation with field-installed conductors of 60ºC minimum rating. 57
58 1-Pole Power Pack (347-1) Details Electrical Connections CCP-PP D Dimensions & Mounting The power pack shall be mounted inside an electrical junction box or panel with a ½ threaded nipple. CCP-PP D * Application and Performance Specification Information Subject to Change without Notification 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 58
59 2-Pole Power Pack ( ) Technical Data Part No CCP-PP20-2P-D 2-Pole 120/277VAC Features Designed for use with Diversa occupancy sensors and Diode Pulse relays. 2 pole 120/277 Specification Load Voltage 120/277 VAC 60 Hz Switched Load 120/277 VAC 2-Pole Independent Switching See Table for contact rating Use #14 AWG Wire Inputs Diode Pulse #18AWG wire Output Power Source 24 VAC, 150 ma #14AWG wire Approvals Certified to CAN/CSA Std. C22.2 No. 14 Conforms to UL 508 Standard FCC Title 24 Plenum Rated Class 2 Rating Environment Indoors, stationary, non-vibrating, non-corrosive atmosphere and non-condensing humidity Ambient Operating Temperature : 14 F to 140 F (-10 C to 60 C) Storage Temperature : -14 F to 140 F (-25 C to 60 C) 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 59
60 2-Pole Power Pack ( ) Technical Data & Details Operation The CCP-PP20-2P-D Power Pack work in conjunction with the Diversa Low Voltage Sensors by providing power to the sensors and receiving on/off commands from the sensor. Contact Load Rating Voltage General Tungsten Standard Ballast Electronic Ballast 120V 20A 20A 20A 16A 277V 20A 20A 20A 16A All Power Packs provide a 24 VAC secondary source for use with the Low Voltage Diversa Sensors and other Diode Pulse devices. All switches or loads required to be supported by the sensor must be included in the loading capacity of the Power Pack. Voltage Maximum Load Per Input Max# of linked sensors 24V 12 Typical Low Voltage Loads Device Part# Current (ma) Ceiling Mounted Sensor Wall Switch Sensor Wall Mount Sensor CCOR/CCVR CCOS/CCVS CCOW/CCVW 9,5mA Standard 14,0mA w/aux Relay Diode Pulse Switch WR mA Installation & Wiring Directions Installation The power pack shall be mounted inside an electrical junction box or panel with a ½ threaded nipple. CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE Wiring The power packs are equipped with #14 AWG stranded leads. Use appropriate sized wire-nuts to connect the wires to the incoming load terminations. For installation with field-installed conductors of 60ºC minimum rating. 60
61 2-Pole Power Pack ( ) Details Electrical Connections CCP-PP20-2P-D Dimensions & Mounting The power pack shall be mounted inside an electrical junction box or panel with a ½ threaded nipple. CCP-PP20-D * Application and Performance Specification Information Subject to Change without Notification 2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F info@cristalcontrols.com cristalcontrols.com 61
Dual Technology Wall Switch Occupancy Sensor. Manual & Specification
Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION
More informationDual Technology Wall Mounted Occupancy Sensor. Manual & Specification
Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION
More informationSpecifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950
1 Specifications Occupancy/Vacancy Sensors CSI 26.09.23. ASHRAE 90.1-2010 AIA Division 16 Section 16950 1. PART 1 - General 1.1 Overview 1.1.1 Provide Occupancy/Vacancy sensors as shown on the plans and
More informationOccupancy and Vacancy Sensors
Occupancy and Vacancy ensors Diversa PIR ensors PIR sensors are the right choice for spaces with a high level of occupant movement and a clean line of sight to the sensor. WOR eries Features Perfect for
More informationMini Product Guide.
Mini Product Guide www.acuitybrands.com/sensorswitch Better Performance Through Advanced Technology 100% Digital Passive Infrared (PIR) Detection Dual Technology Detection utilizing Microphonics Contractor
More informationProduct Specifications Dialog Room Controller* (*patent pending)
1 Product Specifications Dialog Room Controller* (*patent pending) 1. GENERAL 1.1. OVERVIEW 1.1.1. Provide a complete stand-alone, decentralized, low voltage, digital lighting control system for classrooms,
More informationCeiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1
Occupancy and Vacancy Sensors ENERLITES offers a wide variety of lighting sensors. They are designed to bring convenience to your life and business while helping to reduce energy consumption in commercial,
More informationTable of Contents Dialog Panel Based System Dialog Room Controller
Table of Contents Dialog Panel Based System 3 WLCP Lighting Control Panel 4 WLC-4150 Lighting Control Unit 9 Transformer 11 Relays 13 Global Web Server 15 Graphical User Interface Device 17 Modules WDB-3314
More informationLS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors
Datasheet Ceiling mount occupancy sensors Overview The CM Series of ceiling mount occupancy sensors provide a range sensor solutions for applications with finished ceilings (e.g., ceiling tiles, sheetrock,
More informationPSC-ID-x-CM Series Ceiling Mount Occupancy Sensor
TECHNICAL SPECIFICATIONS PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor Basic Features Line voltage version: 120-277VAC, 60Hz Low voltage version: 24VDC, requires separate class 2 power supply PIR sensor
More informationNational Grid Small Business Program Rebate Manual
National Grid Small Business Program Rebate Manual Rebate Manual Munro Distributing has prepared this manual to aid you and your clients in taking advantage of available rebate programs offered by National
More informationSENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1
SENSORS ENERLITES offers a wide variety of Occupancy and Vacancy sensor models that can monitor virtually any area within a building. We cover the spectrum of technologies with our passive infrared, basic
More informationADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR
ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR 5/9/18 Procurement Towson University 8000 York Road Towson, MD 21252-0001 t. 410 704-2171 f. 410 704-8233 Ladies and Gentlemen:
More informationVersatile wall switch sensors maximize payback and simplify code compliance
Versatile wall switch sensors maximize payback and simplify code compliance Commercial Wall Switch Occupancy Sensors MANUAL-ON MULTI-WAY NIGHTLIGHT Achieve the best energy savings for every wall switch
More informationLPCMPIRM65 & LPCMPIRDSI65
Product Guide LPCMPIRM65 & LPCMPIRDSI65 Luminaire high mount PIR detectors Overview The LPCMPIR PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual
More informationSensors and Detectors
12/12/2017 Sensors and Detectors - Clipsal by Schneider Electric Sensors and Detectors Add sensors and detectors to make an environment smarter and more efficient. C-Bus sensors and detectors allow environmental
More informationCeiling PIR HS presence detector. Product Guide. Overview. Features
Product Guide 796-2047 Ceiling PIR HS presence detector Overview The 796-2047 (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. This is a high
More informationF series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC
echoflex Powered by ETC Complete Room Controller F series ERDRC-FC This guide covers the F series of the Complete Room Controller, model number ERDRC-FCU equipped with a 902 MHz radio. The box contents
More informationIN2 Lighting Control Devices
Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Lighting Control Devices Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals
More informationCONTENTS SENSOR SWITCH
FOCUS ON LIGHTING CONTROL With each product or new technology we develop, our objective is to continually achieve greater energy savings with outstanding user convenience. Our particular focus on lighting
More informationInstallation Instructions
DT-300 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features Specifications Voltage................18-28VDC/VAC, half wave rectified AC Current Consumption...............................43mA
More informationTechnology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2
Passive Infrared Sensors (PIR) Using a patented fresnel lens which minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor breaks its coverage area into zones. Upon detecting an infrared
More information, ,
796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control
More informationPassive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit
Instruction Bulletin 63249-420-418A1 02/2014 Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit Commercial Grade with Ground SLSPWD1277C Retain for Future Use INTRODUCTION The Passive Infrared
More informationDual Relay Multi-Technology Wall Switch Occupancy Sensors
Dual Relay Multi-Technology Wall Switch Occupancy Sensors The OSSMD line of dual relay multi-technology Decora style wall switch occupancy sensors features several models to provide automatic lighting
More informationOccupancy Sensor LS Descriptions. Product Profile. Technical Specifications
LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and
More informationMaestro 0 10 V Dimmer Sensor
NEW Maestro 0 10 V Dimmer Sensor Setting the new standard for 0 10 V control 0 10 V Dimmer Sinking control for 0 10 V fluorescent and LED fixtures Passive Infrared (PIR) Sensor Fine motion detection with
More informationCeiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver
Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with
More informationv3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature
DT-300 v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature Specifications Voltage...18-28VDC/VAC, half wave rectified AC Current Consumption...25
More informationCS1200 WHT Pir Ceiling Mount Occupancy Sensor
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Area Coverage Field of View Load Type
More informationTable of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5
Sensor Buying Guide Table of Contents Sensor Models 2 Advantages of Sensors 3 FAQs 4-5 Occupancy and Vacancy Sensors, which provide automatic switching of lighting and motor loads, are fast becoming a
More informationEBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features
Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual
More informationF series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC
echoflex Powered by ETC ER1S-FC Slim Line Dimming Controller F series This guide covers the F series of the Complete Room Controller, model number ER1S-FCU equipped with a 902 MHz radio. The box contents
More informationInfrared Wall Mount Occupancy Sensor
LOS-WI LOS-WI-1 02.01.06 Infrared Wall Mount Occupancy Sensor The LOS-WI wall-mounted passive infrared sensor is used in spaces with pendant fixtures, ceiling fans, or high ceilings (more than 12 feet).
More informationLighting Control Strategies. to meet code requirements save energy and improve building performance
Lighting Control Strategies to meet code requirements save energy and improve building performance 1 Lighting Control Strategies Agenda Why Lighting Control Manual Light Reduction Scheduling Occupancy
More informationPIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features
Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional
More informationInterior Control Solutions
Interior Control Solutions Passive Infrared (PIR) Technology PIR sensors use a semiconductor detector to sense movement of heat emitted from the human body Sensors respond when a person moves from one
More information600 Watt Dimmer Install Guide
600 Watt Dimmer Install Guide ER6CD This guide covers all models of the ER6CD lighting controller. The box contents includes the controller with lock nut and installation guide. Overview The ER6CD controller
More informationPSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor
TECHNICAL SPECIFICATIONS PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor Overview Quad Element PIR sensor 0-10V configurable output: set to 0% (OFF)*, 10%, 25% or 50% dimming Photocell for ambient light
More informationENERGY EFFICIENCY EXPERTS
ENERGY EFFICIENCY EXPERTS Sensors maximize energy savings by ensuring that lights are turned off or to a lower level when spaces are unoccupied or adequate daylight exists. WattStopper s sensors provide
More informationLPC3BSP65 & LPC3BDP65
Product Guide LPC3BSP65 & LPC3BDP65 Batten mount PIR detectors Overview The LPC3B series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional
More informationHigh bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver
Product Guide EBDSPIR-HB-AD High bay PIR presence detector 1-10V dimming Overview The EBDSPIR-HB-AD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual
More informationCeiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions
Ceiling-Mounted Motion Detector 752/CD, 752/CP, 752/CU and 752/Cx180 Installation Instructions Contents 1.0 Description...3 1.1 Contents of the Box...3 2.0 Safety...4 3.0 Coverage Patterns...4 3.1 PIR
More information0ACDT2000MV Ultasonic/Infared Occ Sensor
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 0ACDT2000MV Ultasonic/Infared Occ Sensor Eaton Lighting Catalog Number 0ACDT2000MV Manufacturer Eaton Lighting Description
More informationArrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations
Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s sensors and dimmers are cost -effective
More informationHUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004
HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004 EPA Green Lights A L L Y USE OF THIS LOGO DOES NOT IMPLY EPA ENDORSEMENT APRIL 2008 www.nsiindustries.com E-mail: nsi@nsiindustries.com Fax:
More informationWelcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647
Lightcloud is a commercial wireless lighting control system & service. It s powerful and flexible, yet easy to use and install. Learn more at lightcloud.com 1 (844) LIGHTCLOUD 1 (844) 544-4825 support@lightcloud.com
More informationDIMMING WASP Occupancy and Daylight Sensor
DIMMING WASP Occupancy and Daylight Sensor www.hubbell-automation.com Lighting Control Has Never Been More Essential Energy conservation initiatives, ever-evolving lighting codes and LED technology are
More information64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).
Flush Mount PIR Motion Sensor PIR 1-10V Dimming with Remote Control Mechanical Structure 70mm 64.7 4 56 68.1 73.3 Ø85 3 (1) Sensor inset (2) Lens pluggable Infrared receiver 1 Photocell LED indicator (3)
More informationEBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features
EBDHS-DD-LT30 Product Guide Ceiling PIR HS presence detector DALI / DSI, low temperature Overview The EBDHS-DD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads
More informationApplied Lighting Controls
Better Buildings By Design 2010 Applied Lighting Controls Steven Mesh, LC, IESNA Senior Lighting Program Coordinator Pacific Energy Center (Pacific Gas & Electric) 851 Howard Street, San Francisco, CA
More informationSECTION LIGHTING CONTROL DEVICES
SECTION 16145 LIGHTING CONTROL DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationMicrowave/PIR Intrusion Detector with POPIT Interface ZX970
Microwave/PIR Intrusion Detector with POPIT Interface ZX970 Installation Instructions 1.0 Specifications Input Power: 9 to 15 VDC, 6 ma nominal (35 ma with LED on) Zonex Current Draw: 500 ma Standby Power:
More informationFR-A180 FR-A360. Occupancy detector. Use
5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable
More informationHigh bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver
EBDSPIR-HB-DD Product Guide High bay PIR presence detector DALI / DSI dimming Overview The EBDSPIR-HB-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional
More informationVITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features
Product Guide VITMR-EBDSPIR-PRM PIR Presence/Absence Detector IR with Ceiling Rose Overview The VITMR-EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads.
More informationVive PowPak Fixture Controls
Vive 369918g 1 03.12.18 The PowPak wireless fixture control is a radio-frequency (RF) device that controls either the Lutron EcoSystem or 0 10 V- electronic fluorescent ballasts and LED drivers (depending
More informationH-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared
H-MOSS Occupancy and Vacancy Sensors H-MoSS Hubbell Motion Sensing Switches Tomorrow s Technology Today! Adaptive Technology Dual Technology Ultrasonic Technology for Today s Needs Dual Technology H-MOSS
More informationInfrared Ceiling Mount Sensor
Infrared Ceiling Mount Sensor LOS-CI Series LOS-CI- 0.0.06 The LOS-CI Series ceiling-mount passive infrared sensors can integrate into Lutron systems or function as standalone controls using a Lutron power
More informationDHL-LP-LED Low Profile LED Linear High/Low Bay
Job Information Type: Catalog #: Project: Comments: Prepared by: WARRANTY WARRANTY YEAR TEN INCLUDES LABOR ALLOWANCE 2 65W/90W Version 23.81 2 135W Version For 4 dimensions see pg 2 23.81 23.81 23.81 12.6
More informationProduct Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.
PPAD-C-HB-DALI-230V Product Guide Ceiling PIR HS presence detector DALI / DSI dimming Overview The PPAD-C-HB-DALI-230V PIR (passive infrared) presence detector provides automatic control of lighting loads
More informationA. This Section includes the following lighting control devices:
Attachment G LIGHTING CONTROL SPECIFICATIONS (Download Document separately) LIGHTING CONTROL SPECIFICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including
More informationA. This Section includes the following lighting control devices:
SECTION 26 09 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationInfrared Ceiling Mount Sensor
Infrared Ceiling Mount Sensor 69655c 0.07. The LOS-CIR Series passive infrared ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack. The
More informationCeiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.
MWS6-DD-LV Product Guide Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC Overview The MWS6-DD-LV microwave presence detector provides automatic control of lighting loads with optional manual
More informationArrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations
Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s s and dimmers are cost -effective
More informationWireless Plug Load Control
General Specification Wireless Plug Load Control Model No.: PL20R & PLBPC Description:Enerlites Wireless Plug Load Controller is designed with simplicity, and helps to make plug load control requirements
More informationCeiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.
Product Guide EBDSM-DD Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSM-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual
More informationCeiling-Mounted Wireless Occupancy/Vacancy Sensor
Project name Prepared by Date INDOOR AIRLINK enabled by Lutron Catalog #: ALW OS/VS CM Part #: 624094 624615 The Ceiling-Mounted Wireless Occupancy & Vacancy Sensors are wireless, battery- powered, passive
More informationIntegrated PIR detectors
EBMINT - Product Guide Integrated PIR detectors Overview The EBMINT series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control
More informationDouglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7
Bluetooth Fixture Controller & Sensor BT-FMS-A Installation Manual *Patent Pending www.douglaslightingcontrols.com 1 This page intentionally blank. www.douglaslightingcontrols.com 2 WARNING! SYSTEM MUST
More informationEver evolving energy code requirements and the large demand for energy
Ever evolving energy code requirements and the large demand for energy saving products have made lighting control sensors a must-have for building owners and managers. Hubbell Control Solutions introduces
More informationMWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features
Product Guide MWS5 Miniature Microwave Presence Detector (standalone) Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual
More informationIntroduction to Flow Switch
Introduction to TM Solutions Flow Detection, Switching & Control Flow switches detect a change in state from flow or no-flow within pipe or ducting. Correspondingly, the sensor inverts a contact to signal
More informationEBDSPIR-PRM-LV Product Guide
EBDSPIR-PRM-LV Product Guide Ceiling PIR presence/absence detector 12-24V AC/DC Overview The EBDSPIR-PRM-LV PIR (passive infrared) presence detector provides automatic control of low voltage loads including
More informationINTEGRATED LIGHTING CONTROLS
INTEGRATED LIGHTING CONTROLS With many facilities looking at lighting upgrades as a great energy-saving strategy, embedding controls directly into the fixture makes good economic sense. Choose just the
More informationLUX Hardwired - Installation Notes
Ness LUX wired PIR with Nightlight Quad element pyro sensor 15m x 15m wide angle coverage Look down Creep Zone Selectable Standard and Pet Aware modes Adjustable sensor mask for No Creep and Pet modes
More informationBuilt-in HF Sensor for High Bay
Daylight Monitoring RX TM Synchronisation control Ambient daylight threshold Built-in HF Sensor for High Bay HC419VRC/R Tri-level Control With Synchronisation and Remote Control Applications Occupancy
More informationIP65 High Bay Dual Sense Sensor
IP65 High Bay Dual Sense Sensor TM and, Daylight Harvest with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High
More informationMovement Detector GJD 300
Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before
More informationPPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features
Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The
More informationWherever the best is needed. Sensors for professionals.
Wherever the best is needed. Sensors for professionals. 3 Presence Detectors Motion Detectors (indoor) Power Packs Wallswitches from page 14 from page 4 from page 52 from page 6 IR Quattro HD IR Quattro
More informationMPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features
Product Guide MPAD-C 12-24V Ceiling microwave presence/absence detector 12-24V AC/DC Overview The MPAD-C 12-24V Microwave presence detector provides automatic control of low voltage loads including lighting
More informationFalse Ceiling HF Sensors
False Ceiling HF Sensors HC009S/EXT HC018V/EXT HC019V/EXT Applications Ideally suited to retrofit projects where the luminaire is too small to accomodate the sensor internally, this motion sensor can be
More informationLighting Control Solutions for Parking Facilities
Lighting Control Solutions for Parking Facilities Control Safety, Connect Strategies, and Commission Zones Parking Lighting Strategies for Optimal Performance Historically, parking garage lighting was
More informationCXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION
CXB Series LED Luminaire Junction Box, Pendant and Hook and Cord IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND
More informationRooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers
Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers TABLE OF CONTENTS Overview 2 VT86X0U5X00B 2 heating / 2 Cooling for Rooftop unit and Indoor air quality 3
More informationNever forget to turn the lights off again. Motion Sensors
Never forget to turn the lights off again. Motion Sensors by Why use motion sensors? Motion Sensors Everyone knows that you can save energy by turning off lights when they re not being used. Even so, sometimes
More informationInstallation Instructions
Specifications PW-100 PW-200 PW-100/PW-100-347/PW-200/PW-200-347 v3 Passive Infrared Wall Switch Occupancy Sensor PW-100-347 PW-200-347 Voltages: PW-100 & PW-200................ 120/277VAC, 50/60Hz PW-100-347
More informationEBMHS (standard & slim-line PSU)
Product Guide EBMHS (standard & slim-line PSU) Miniature HS PIR Presence Detector (luminaire fitting) Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic
More informationSection 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.
CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions 1 PACKAGE CONTENTS Wiring Harness 6 Wire Nuts #6 x 3/4 Screws s BP7175 3/16 Wall Plugs Section 1: General Description Camden CM-RQE-70 Request-to-Exit
More informationEmerald 3000 MK3 GJD010 Lighting Controller
Emerald 3000 MK3 GJD010 Lighting Controller SPECIFICATION SUPPLY: 230 Vac 50Hz via ELCB/MCB - unit fused at 13A 12VDC@ 100mA: GJD Opal XL (6mA) or Elite Detectors (10mA) Optional external 12VDC piezo sounder
More informationIP65 High Bay Dual Sense Sensor
IP65 High Bay Dual Sense Sensor TM and, 1-10V Dimming with Remote Control Technical Data Input Characteristics Sensor Data Model No. Model No. Mains voltage 220-240VAC 50/60Hz Sensor principle High Frequency
More informationSECTION. Occupancy Sensors & Lighting Control Products
SECTIO s & Lighting Control Products Infrared s Features and Types Leviton provides a variety of spacemonitoring Lighting Controls for virtually any room, space, facility, home or office. Wall or ceiling,
More informationTrueAlarm Analog Sensing
UL, ULC Approved* TrueAlarm Analog Sensing TrueAlarm Analog Sensors Photoelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: Digital transmission of analog sensor
More informationCM-RQE70 PIR REQUEST TO EXIT DETECTOR
Door Activation Devices CM-RQE70 PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (1) Wiring Harness (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (6) Wire Nuts (2) 's BP7175 1. GENERAL DESCRIPTION Camden
More informationTri-level Control Sensor
Daylight Monitoring Photocell Advance TM One-Key Commissioning Ambient daylight threshold oop in oop out Tri-level Control Sensor HC038V HCD038 Detached inear Version with Remote Control Applications Occupancy
More informationTouch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings
Touch Screen Thermostat MTSC/SUPER, MTSC24/SUPER Series MTS/SUPER, MTS24/SUPER Series Owner s manual and technician settings -2 - Index 1. Owner s Manual... 4 1.1 Quick Guide. 4 1.2 Turning the unit ON
More informationInstallation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Versatility. Maximum Energy Savings
Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy Savings Maximum Versatility Sensitive 140 view passive infrared motion detector keeps lights on only when rooms are in use. Switches
More informationProduct Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.
Product Guide LPCMPIRDSI Ceiling PIR presence detector DALI / DSI dimming Overview The LPCMPIRDSI PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual
More information