HPIC Meeting - Austin

Size: px
Start display at page:

Download "HPIC Meeting - Austin"

Transcription

1 HPIC Meeting - Austin Barry Wilson Key Account Manager South West ORTEC 1

2 Who is ORTEC? Parent Company is AMETEK NYSE ticker AME Subsidiary Name is Advanced Measurement Technologies Inc. Brand Names are ORTEC, Princeton Applied Research and Signal Recovery ORTEC was founded in 1960 by Researchers from ORNL to build commercial charged particle detectors made of semi-conductor materials (silicon). Currently about 280 employees world-wide. Factory in Oak Ridge 2

3 Key Technology: HPGe Detectors ORTEC is a world leader in nuclear instrumentation, including both growing HPGe crystals and fabricating detectors. ORTEC has significant experience in large scale production of HPGe detectors for a variety of projects. 3

4 Key Technology: DSP Hardware ORTEC was first to commercialize Digital Signal Processing (DSP) technology in an integrated gamma ray spectrometer. ORTEC holds nine separate patents in the area of DSP based MCA technology alone. 4

5 Key Technology: Coolers Electromechanical cooling system for Fixed/Installed Applications Portable Cooling System for the Field Since 1984, ORTEC has delivered more LN2 free HPGe cooling systems than any company in the world. Patented Low Frequency Rejection digital filtering makes it work. Hundreds of reliable systems delivered per year. 5

6 Key Technology: Software Found Industrial(1) Suspect NORM(1) Found Nuclear Uranium High degree of collaboration with national laboratories for state of the art analysis methods. Broad-based software group continually working on an equally broad range of new products (both nuclear and otherwise) ensures we keep up with technology. 6

7 Radiological/Nuclear Terrorism Preventing the Spread of Illicit Nuclear Materials 7

8 Potential Points of Entry 8

9 The Cost of False Alarms False Positives (nuisance alarms) 90% of innocent alarms at airports are due to medical isotopes in the bodies of travellers In cargo/freight, the major problem is caused by natural emitters. Suspending operations in just one terminal for just one hour could cost close to $500,000, said Bethann Rooney, Port Authority s Manager of Port Security, New York Harbor. False Negatives Report cargo is clean when in fact a source is hidden inside 9

10 Review: Why use HPGe? Plastic HPGe NaI CZT LaBr 10

11 Shielded Plutonium with Barium Barium Plutonium 11

12 Plutonium with 133 Ba Mask Peaks from 133 Ba intermingle with plutonium peaks Shielded with 5 mm steel Collection time for identification is 5 seconds The 133 Ba lines are separated from the 239 Pu lines allowing the identification software to identify plutonium 12

13 Enter the DETECTIVE Portable Nuclide Identifiers! Detective DX/EX & MicroDetective One button sophisticated search/identify tool for non-scientist users Unique Combination of exclusive technologies ORTEC Germanium detector with miniature Sterling engine cooler ORTEC Digital signal processing electronics, embodying several patents Special ID software licensed from the LLNL Radscout 13

14 DETECTIVE DX/EX Common Hardware Features 50x30mm or 65x50mm HPGe detector Run for ever Cooler Gamma ID and Gamma Dose rate Digital MCA 8K channels ~11 Kg weight (EX~12Kg) Battery operation >3Hr Battery Extender = 8hr Docking station optional Hardened cryostat 14

15 DETECTIVE DX/EX differences EX adds Highly sensitive neutron detection -- 4 x 3 He tubes - 4" active length, 0.5" diameter, 20atm. HDPE moderator Color Touch Screen Display on DX and EX DX and EX unlimited data storage on removable media 15

16 The Nuclides Industrial Including, but not limited to 57 Co, 60 Co, 133 Ba, 137 Cs, 192 Ir, 241 Am, 75 Se Medical Including, but not limited to 18 F, 67 Ga, 99m Tc, 111 In, 123 I, 131 I, 133 Xe, 201 Tl Natural (NORM) Including, but not limited to: 40 K, 226 Ra, 232 Th, 238 U Nuclear Including, but not limited to 233 U, 235 U, 237 Np, 239 Pu, 252 Cf 16

17 All versions are simple in use... DX/EX & Micro Clear touch screen (use stylus or finger) 17

18 PRIMARY ID SCREENS, Classification of suspect or found nuclides by type Found Industrial(1) Suspect NORM(1) Found Medical(1) A single keystroke leads to... 18

19 ..Found Nuclides Screens Cs137 TC99m 19

20 SNM Search Mode 20

21 The Micro Detective Smaller (-50%) Lighter (-40%)~15lb More Rugged More capabilities Same sensitivity Easier to use STIRLING COOLER Compared to the Detective-EX 21

22 The Micro Detective 50 mm diameter by 30 mm deep HPGe COAX Wireless control Integral GPS Digital electronics inc LFR noise reduction filter Single 3 He Neutron Detector 22

23 The Micro Detective-HX One-handed control of instrument through two handle-mounted buttons, or through touch screen. Visual Alarms: LEDs provide clear and simple indication of nuclide type: threat, innocent or suspect, plus error indication. Vibrating alarm built into handle. 3-level auditory alarms can be routed through headphones. 23

24 The Micro-trans-Spec A Portable HPGe Spectroscopy System Micro-trans-SPEC Applications Nuclear Materials Hold-Up Nuclear Safeguards Inspection In-situ Waste Assay Measurements Emergency Response Reactor Maintenance Medical Physics 24

25 Detective/TransSpec series Nuclide Identifiers Detective DX Detective EX Detective DX 100 Detective EX 100 Portable Ge Systems TransSpec DX TransSpec DX 100 Micro-TransSpec MicroDetective MicroDetective-HX 25

26 Detective Customer List United States DOE Laboratories Los Alamos National Laboratory Lawrence Livermore Laboratory Sandia National Laboratory Pacific Northwest Laboratory Idaho National Engineering Laboratory Savannah River National Laboratory United States Customs and Boarder Patrol (CBP) United States Department of Justice -- FBI United States Department of Defense DTRA DISA DIA USAF United States National Guard Civil Support Team Environmental Measurement Laboratory (DHS) Federal Emergency Management Agency (DHS) Radiological Assistance Program (DOE) State of Illinois Emergency Management Agency District of Columbia Bomb Squad District of Columbia Park Police Canada Homeland Security Organization Canada Border Services United Kingdom Ministry of Defense United Kingdom Home Office British Nuclear Fuels, UK IRSN Fontenay aux Roses, France IAEA Austria Fraunhofer Institute Germany DARD Northern Ireland London Fire Brigade 26

27 Interchangeable Detector Module Large 85 mm x 30 mm HPGe crystal Stirling cycle cooler Hardened cryostat: long life Temperature cycle any time Digitally stable signal processing Hot swap in operational state reduced downtime USB 2.0 data communications Continuous data collection, no dead spots, list mode Low power consumption Low Frequency Rejection filter (LFR) 27

28 HPGe Detector Assemblies the IDM 28

29 IDM Applications 29

30 EASY-MCA-2K/8K Non NIM 2k or 8k MCA USB 2 Interface Fast Conversion (<2-microseconds) Gate Input BUSY and PUR inputs for Dead Time Corrections Includes Maestro-32 (model A65-B32) Software 30

31 Introducing the DSPEC-LF A powerful Entry Level DSP Ultra-stable digital spectrometer Automatic optimization of detector parameters make setup simple (ORTEC Patented PZ Adjust) ORTEC SMART-1 intelligent HPGe support: display detector status and state-of-health Ballistic deficit correcting digital filter for optimum resolution for large detectors Fast data transfer; live spectrum display via the familiar MAESTRO-32 or other ORTEC software products Easy installation: true plug-and-play on USB 2.0 Full computer control of every function 31

32 A New Carbon Fiber Endcap for HPGe detectors 32

33 Detector Construction Major contributor to spectrum counts Mounting cup 33

34 Transmission (fraction) Low Background Carbon Fiber is: virtually background free As strong as an all Al endcap Can see lower than 10-keV Transmission through Beryllium and Carbon (0.76 mm) Carbon (all) Beryllium (Ultra) Carbon Transmission is 73% of Beryllium Energy (kev) 34

35 Industrial Detector -HE option Environmentally Hardened Detector: Impervious to Dust and Grit Sealed Electronics Chamber for Use in High Humidity Environments Splash Proof Corrosion Proof Carbon Fiber Endcap allows use in harsh environment without loss of low energy efficiency 35

36 Software Developments ISOPLUS 4 for analysis of waste samples ANGLE for analysis of bottles and marinelli beakers Both based on primary point source calibrations -use with any HPGe detector 36

37 ISO-Plus Version 4.1 Analysis Software for Waste Containers and In-Situ Measurements 37

38 Six correction factors are calculated Container Matrix Collimator Geometry Self-Attenuation Air 38

39 ANGLE calibration for bottles and marinelli beakers etc An add-in to GammaVision Takes the GammaVision (traceable) point source calibration and extrapolates to calibration for close object such as Marinelli or Bottle. Same point kernel approach as IsoPlus 39

40 Questions? 40

ORTEC. Detective-Remote. Multiple Instrument Remote Monitoring and Control Software. The right software, the right solution, the right answer!

ORTEC. Detective-Remote. Multiple Instrument Remote Monitoring and Control Software. The right software, the right solution, the right answer! ORTEC Detective-Remote TM Multiple Instrument Remote Monitoring and Control Software The right software, the right solution, the right answer! Detective-Remote TM Detective-Remote is a Windows -based software

More information

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems DSPEC Pro: Advancing the Art of Digital Gamma-Ray Spectroscopy The immense versatility of DSPEC Pro, brought about by the number of unique

More information

Portable Instruments For First Response & In-Situ Analysis of Radiation

Portable Instruments For First Response & In-Situ Analysis of Radiation WWW.NATS-USA.COM Portable Instruments For First Response & In-Situ Analysis of Radiation North American Technical Services Bridging Technology With Latest in Radiation Detection Systems & Solutions The

More information

North American Technical Services

North American Technical Services WWW.NATS-USA.COM High Resolution Detectors (HPGE) North American Technical Services Bridging Technology Innovative Solutions In in Radiation Detection and & Analysis High Resolution Germanium Detectors

More information

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price. ORTEC High-Performance Digital Signal Processor for Gamma Spectroscopy Full-featured, digital spectrometer for HPGe and NaI detectors Automatic optimization for best detector performance (patented) ORTEC

More information

Detective-200. Ruggedized, Ultra-High-Sensitivity, Transportable HPGe Radionuclide Identification System

Detective-200. Ruggedized, Ultra-High-Sensitivity, Transportable HPGe Radionuclide Identification System Detective-200 Ruggedized, Ultra-High-Sensitivity, Transportable HPGe Radionuclide Identification System TM No other radiation instrument has more standoff nuclide identification performance in a small

More information

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D.

Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D. Instrument Standards Used in Security Applications Presented by: Leticia Pibida, Ph.D. leticia.pibida@nist.gov Summary of NIST Efforts in DHS/DNDO Standard development Work Consensus standards ANSI/ IEEE,

More information

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor FEATURES: HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS (EPA s PROTECTIVE ACTION GUIDELINE LEVELS) REAL TIME, IN-LINE, CONTINUOUS

More information

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

Performance of a New Type of Electrical Cooler for HPGe Detector Systems Performance of a New Type of Electrical Cooler for HPGe Detector Systems Broerman E. 1, Upp, D. L. 1, Twomey, T. R. 1, and Little, W. A. 2 1 ORTEC, PerkinElmer Instruments, Inc 801 South Illinois Avenue,

More information

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System FEATURES: HIGH GAMMA SENSITIVITY MULTI-CHANNEL ANALYZER (MCA) WORKS WITH VARIETY OF PROBES RADIONUCLIDE LIBRARY TAILORED TO CUSTOMER REQUEST SIMULTANEOUSLY MEASURES ; DISPLAYS; ALARMS 1-3 SEPARATE DETECTORS

More information

Setting the new standard for personal radiation detection.

Setting the new standard for personal radiation detection. Setting the new standard for personal radiation detection. Thermo Scientific RadEye SPRD Personal Radiation Detector Definitive answers through pin-point accuracy The Thermo Scientific RadEye SPRD personal

More information

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR FEATURES: WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS Protective Action Guideline Levels and Military Drinking Water Limits REAL TIME, IN-LINE, CONTINUOUS DETECTS ALPHAS,

More information

Radiation Monitoring Systems

Radiation Monitoring Systems Radiation Monitoring Systems Certificate No. 3250 Contents A guide to Southern Scientific radiation monitoring systems Area Gamma & Interlock Systems (page 3) AGM3 AUTOMESS 6150 Contamination Monitors

More information

RIID capability in the palm of your hand

RIID capability in the palm of your hand RIID capability in the palm of your hand Thermo Scientific RadEye SPRD-GN Personal Radiation Detector Changing the game The Thermo Scientific RadEye SPRD-GN delivers unprecedented detection. The first

More information

NEW COOLING OPTION FOR DETECTORS

NEW COOLING OPTION FOR DETECTORS ORTEC News Issue 11 Welcome to the ORTEC Newsletter This edition concentrates on a number of our recent new product launches starting with the introduction of the new MÖBIUS liquid nitrogen recycler. Other

More information

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY ABOUT COMPANIES Pico Envirotec Inc., CA Pico Envirotec

More information

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP Saudi Arabia : info_ksa@magusintl.com U.A.E : info_uae@magusintl.com Detecting Radiation Animations in this training work best in Windows XP February 2006 Why Detect Radiation Today? Medicine Imaging Cancer

More information

ICS Integrated Cryocooling System

ICS Integrated Cryocooling System ICS Integrated Cryocooling System Premium detector resolution and LN 2 -free operation, for excellence in performance, safety, reliability and value. Introduction ICS ORTEC s newest integrated, mechanically

More information

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation Lodewijk van den Berg, Alan E. Proctor, Ken R. Pohl, Alex Bolozdynya and Raymond DeVito Constellation

More information

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE LEARNING OBJECTIVES: 2.19.01 Describe the features and specifications for commonly used laboratory counters or scalers: a. Detector type b. Detector shielding c. Detector window d. Types of radiation detected

More information

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION SEAWATER RADIATION DETECTION SYSTEM FEATURES: MEASURES AT OR BELOW EPA/DHS PAG LEVELS Protective Action Guideline & Military Drinking Water Limits REAL TIME, IN-LINE, CONTINUOUS DETECTS ALPHAS, BETAS AND

More information

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants. Germanium Detectors The Company Canberra Industries is the world's largest manufacturer of nuclear radiation detection and analysis systems. In order to better serve our customers worldwide, Canberra operates

More information

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) Ganibu Dambis 26, P.O.Box 33 Riga, LV-1005, LATVIA Tel. (+371)6738-3947 Fax:(+371)6738-2620 office@bsi.lv www.bsi.lv CONTENTS INTRODUCTION...

More information

AERIAL RADIATION DETECTORS

AERIAL RADIATION DETECTORS DRONE READY AERIAL RADIATION DETECTORS DroneSENSOR TM Series Model ~ DroneRAD-ST TM (Search Tool or Mapping) - Gamma Model ~ DroneRAD-P TM (Air Monitor& Plume Detector) Particulate Alpha, Beta, Gamma &

More information

Depleted Uranium Waste Assay at AWE. T.J. Miller AWE, Aldermaston, Reading, Berkshire, England, RG7 4PR UK

Depleted Uranium Waste Assay at AWE. T.J. Miller AWE, Aldermaston, Reading, Berkshire, England, RG7 4PR UK Depleted Uranium Waste Assay at AWE T.J. Miller AWE, Aldermaston, Reading, Berkshire, England, RG7 4PR UK ABSTRACT The Atomic Weapons Establishment (AWE) at Aldermaston has recently conducted a Best Practical

More information

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals DroneSENSOR TM Series Model ~ DroneRAD-ST TM (Search Tool or Mapping) - Gamma Model ~ DroneRAD-P TM (Air Monitor & Plume Detector) Particulate Alpha, Beta, Gamma & Airborne Chemicals DroneSENSOR TM THE

More information

ICS Integrated Cryocooling System

ICS Integrated Cryocooling System ICS Integrated Cryocooling System Premium detector resolution and LN 2 -free operation, for excellence in performance, safety, reliability and value. Introduction ICS ORTEC s newest integrated, mechanically

More information

ICS Integrated Cryocooling System

ICS Integrated Cryocooling System ICS Integrated Cryocooling System ORTEC s most advanced Integrated Cryocooling System offers premium detector resolution and LN 2 -free operation, for excellence in performance, safety, reliability and

More information

Tender Specifications. Supply of radiation detection equipment for EUSECTRA training centre Lot 2: Backpack for portable radiation detection system

Tender Specifications. Supply of radiation detection equipment for EUSECTRA training centre Lot 2: Backpack for portable radiation detection system ANNEX II to Contract Nr.. EUROPEAN COMMISSION JOINT RESEARCH CENTRE (JRC) Institute for Transuranium Elements (Karlsruhe) Nuclear Safeguards and Forensics Unit European Commission Institute for Transuranium

More information

LAUNDRY MONITORING SYSTEM Model # LIM-64S

LAUNDRY MONITORING SYSTEM Model # LIM-64S LAUNDRY MONITORING SYSTEM FEATURES: HIGH SENSITIVITY EVEN TO LOW ENERGY GAMMAS 6 EACH 8 X 8 SCINTILLATORS ABOVE 4 EACH 2 X 12 NaI(Tl) BELOW AUTOMATIC CONVEYOR FOR LAUNDRY AUTOMATICALLY SEPARATES CLOTHES

More information

Advanced Radiation Detection Equipment

Advanced Radiation Detection Equipment Advanced Radiation Detection Equipment Electronic Dosimeters Personal Radiation Detectors Spectroscopic Personal Radiation Detectors Portable Monitors & Radioisotope Identifiers Radiation Fixed Monitors

More information

The European Commission s science and knowledge service. Building on core components of Technical Reachback

The European Commission s science and knowledge service. Building on core components of Technical Reachback The European Commission s science and knowledge service Joint Research Centre Building on core components of Technical Reachback GICNT - Magic Maggiore Workshop 28-30 th March 2017, Ispra G. Takoudis,

More information

Practical Use of the Mobile Radiological Laboratory to Support the Nuclear Regulatory Authority of Ukraine

Practical Use of the Mobile Radiological Laboratory to Support the Nuclear Regulatory Authority of Ukraine Practical Use of the Mobile Radiological Laboratory to Support the Nuclear Regulatory Authority of Ukraine V. Bogorad*, T. Lytvynska*, O. Slepchenko*, Y. Belov*, J.Rautjarvi** * State Scientific and Technical

More information

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS Denis GLAVIČ-CINDRO Toni PETROVIČ Drago BRODNIK Matjaž VENCELJ Jožef Stefan Institute Ljubljana, Slovenia Steven James BELL Lindsey

More information

Presented by: Dr. Francesco Pellegrino Lockheed Martin Corporation Maritime Systems and Sensors Mitchel Field, New York

Presented by: Dr. Francesco Pellegrino Lockheed Martin Corporation Maritime Systems and Sensors Mitchel Field, New York Networked Application of Chemical, Biological, Radiological and Nuclear Detectors for Early Detection and Warning of CBRN Events in Transit Environments Presented by: Dr. Francesco Pellegrino Lockheed

More information

Federal Bureau of Investigation. Training. Agenda. Acronym City. SRNL Counterterrorism and Homeland Security Support Areas

Federal Bureau of Investigation. Training. Agenda. Acronym City. SRNL Counterterrorism and Homeland Security Support Areas Agenda Savannah River National Laboratory Overviews of Department of Homeland Security Test and Evaluation Programs Conducted by SRNL Charles Lewis April 16, 2010 2010 Health Physics Society Technical

More information

MÖBIUS Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System

MÖBIUS Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System All the advantages of Liquid Nitrogen cooling without the need for frequent refilling. The ORTEC Möbius Recycler technology provides tried

More information

CZT/NaI Hybrid Hand-Held Performance Evaluation

CZT/NaI Hybrid Hand-Held Performance Evaluation CZT/NaI Hybrid Hand-Held Performance Evaluation W. Russ, D. Nakazawa, I. Hau, M. Morichi Research and Development Canberra Industries, an AREVA company Meriden, Connecticut, USA wruss@canberra.com Abstract

More information

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology. NRRPT Exam Review Class - an intensive 5-day class designed to prepare the candidate to successfully pass the NRRPT Exam. The course concentrates on the basic tools the candidate needs to successfully

More information

WM2012 Conference, February 26 March 1, 2012 Phoenix, Arizona, USA

WM2012 Conference, February 26 March 1, 2012 Phoenix, Arizona, USA Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533 John A. Mason*, Kevin J. Burke*,

More information

arxiv: v1 [physics.ins-det] 14 Apr 2014

arxiv: v1 [physics.ins-det] 14 Apr 2014 1 arxiv:1404.3563v1 [physics.ins-det] 14 Apr 2014 To appear on the Proceedings of the 13th ICATPP Conference on Astroparticle, Particle, Space Physics and Detectors for Physics Applications, Villa Olmo

More information

Domestic Nuclear Detection Office (DNDO)

Domestic Nuclear Detection Office (DNDO) Domestic Nuclear Detection Office (DNDO) Technologies for Critical Incident Response Conference and Exposition 2006 Radiological and Nuclear Detection Programs September 8, 2006 Howard Reichel DNDO Assistant

More information

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR _ PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR FEATURES: COMPLETELY PORTABLE OR WALL INSTALLATION CAN BE SET TO ANY WIDTH; QUICK SET UP VIDEO REAL-TIME DISPLAY & CAPTURE OPTIONAL: WIRELESS REMOTE NOTIFICATION

More information

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314) Mass Sensors, Inc. 1350 Baur Blvd, St. Louis, MO 63132 (314) 997-5779 www.mass-sensors.com Innovations in chemical microsensors Profile Mass Sensors is a development stage high-tech company operating in

More information

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor NEX-BETA-ABG FACILITY Drinking Water Safety Monitor FEATURES: DETECTS ALPHA, BETA AND GAMMA RADIATION AVAILABLE IN PORTABLE OR INSTALLED VERSION MEASURES AT OR BELOW EPA/DHS PAG LEVELS PROTECTIVE ACTION

More information

American Nuclear Society (ANS)

American Nuclear Society (ANS) What s New... American Nuclear Society (ANS) Project Initiation Notification System (PINS) ANS Standards Before work on a draft can begin, a Project Initiation Notification System (PINS) form must be approved

More information

Countering Nuclear Smuggling in Lithuania: Detection Mr Albinas Mastauskas Director, Radiation Protection Centre LITHUANIA

Countering Nuclear Smuggling in Lithuania: Detection Mr Albinas Mastauskas Director, Radiation Protection Centre LITHUANIA Countering Nuclear Smuggling in Lithuania: Detection Mr Albinas Mastauskas Director, Radiation Protection Centre LITHUANIA albinas.mastauskas@rsc.lt International Conference on Nuclear Security: Commitments

More information

Portable Survey Instruments NISP-RP-01

Portable Survey Instruments NISP-RP-01 NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection NISP-RP-01 This is an industry document for standardizing radiation protection processes used by supplemental radiation protection technicians.

More information

The Majorana Demonstrator Update and Detector Technologies

The Majorana Demonstrator Update and Detector Technologies The Majorana Demonstrator Update and Detector Technologies Lawrence Livermore National Laboratory UC Berkeley Update on the status of Majorana Detector technologies Craig Aalseth DUSEL plans 1 Majorana

More information

Highlights from a recent test campaign in Finland with scalable neutron detectors

Highlights from a recent test campaign in Finland with scalable neutron detectors Highlights from a recent test campaign in Finland with scalable neutron detectors Neutron Users Club Dr. Geraint Dermody Introduction Symetrica s activities and products The NKS (Nordic Nuclear Safety

More information

Highlights of Germanium Detector technology

Highlights of Germanium Detector technology Symposium at Tsinghua University : Application of Germanium detector in Fundamental research Highlights of Germanium Detector technology Dr Marie Odile LAMPERT CANBERRA Lingolsheim Specialty Detectors

More information

Our Extended Personal Electronic Dosimeter (PED) Family

Our Extended Personal Electronic Dosimeter (PED) Family Our Extended Personal Electronic Dosimeter (PED) Family Tracerco s Award Winning Radiation Monitors and Servicing business unit provides a range of products and services accredited to ISO9001:2008 and

More information

Any scenario. Maximum protection. Radiation detection solutions for safety and security

Any scenario. Maximum protection. Radiation detection solutions for safety and security Any scenario. Maximum protection. Radiation detection solutions for safety and security Radiation detection solutions for security personnel Delivering dependable safety and security solutions for over

More information

Domestic Nuclear Detection Office (DNDO)

Domestic Nuclear Detection Office (DNDO) Domestic Nuclear Detection Office (DNDO) Advancing Technological Capabilities to Prevent Nuclear Terrorism 27 October 2016 Joel Rynes, Ph.D., PMP Assistant Director Transformational and Applied Research

More information

Advanced Radiation Measurement Solutions

Advanced Radiation Measurement Solutions GE Energy Advanced Radiation Measurement Solutions Reuter Stokes Radiation Measurement Solutions GE Energy, Edison Park in Twinsburg, OH, USA World-class research and development Beginning with the first

More information

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS Communications. Sensing. Instrumentation. BREAKTHROUGH PHOTONIC PRODUCTS ADVANCED MATERIALS MICRO-MECHANICAL NANO-STRUCTURE TECHNOLOGY Delivering tomorrow s optical and photonic solutions today. Capabilities

More information

TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT

TECHNICAL LEAFLET. The proposed instrument is an extended version of the computerized Geiger-Muller indicator PT PROJECT 01109-4 PRELIMINARY DOCUMENT 01109-4-SD-0001-EN PT01109-4 Fast acquisition time and high sensitivity gamma and beta spectrometer to survey everyday nutrition, hygienic and household goods for radionuclides

More information

ADVANCED RADIATION DETECTION EQUIPMENT

ADVANCED RADIATION DETECTION EQUIPMENT ADVANCED RADIATION DETECTION EQUIPMENT Electronic Dosimeters Personal Radiation Detectors Spectroscopic Personal Radiation Detectors Portable Monitors and Radioisotope Identifiers Radiation Fixed and Deployable

More information

The Development of an Integrated Site System for the detection of illicit trafficking of radioactive and nuclear materials

The Development of an Integrated Site System for the detection of illicit trafficking of radioactive and nuclear materials The Development of an Integrated Site System for the detection of illicit trafficking of radioactive and nuclear materials Kevin Whitehouse, Dan Parvin British Nuclear Group, Project Services Limited,

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA - FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION Up to 6 WEEKS PRINTED RECORD (Optional)

More information

IAEA-SM-367/14/01 UTILIZATION OF FLUORESCENT URANIUM X-RAYS AS VERIFICATION TOOL FOR IRRADIATED CANDU FUEL BUNDLES

IAEA-SM-367/14/01 UTILIZATION OF FLUORESCENT URANIUM X-RAYS AS VERIFICATION TOOL FOR IRRADIATED CANDU FUEL BUNDLES IAEA-SM-367/14/01 UTILIZATION OF FLUORESCENT URANIUM X-RAYS AS VERIFICATION TOOL FOR IRRADIATED CANDU FUEL BUNDLES Iqbal Ahmed 1, Rolf Arlt 2, Victor Ivanov 3 and K G. Qasim 4 [1] Institute for Nuclear

More information

GERDA Phase II Detectors and Acceptance Tests

GERDA Phase II Detectors and Acceptance Tests Detectors and Acceptance Tests Victoria Wagner for the WG Max-Planck-Institut für Kernphysik 01.03.2012 The Experiment Phase I started Nov. 1 st 2011 Currently running with 9 coaxial germanium detectors

More information

Any scenario. Maximum protection.

Any scenario. Maximum protection. Thermo Scientific Radiation Detection Solutions for Safety and Security Thermo Scientific RADSafe Certified Services Configurable services tailored to your specific needs Select from a wide variety of

More information

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications custom scintillation at the core of your optical system High sensitivity

More information

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection Level 3 Information Use NISP-RP-001 Industry Approval Date: September 14, 2018 This is an industry document for standardizing radiation protection

More information

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions. Personal Alpha/Beta Continuous Air Monitor (CAM) The pocamon (personal online continuous air monitor) monitors continuously the breathing air to detect airborne radioactive aerosols (LLRD). Typical application

More information

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14 FEATURES: THREE to SIX CHANNEL SIMULTANEOUS MEASUREMENT OF: BETA-GAMMA PARTICULATE IODINE NOBLE GAS ALPHA PARTICULATE TRITIUM CARBON-14 DETECTORS MORE SENSITIVE BY FACTORS OF 5-500 THAN REQUIRED BY NRC

More information

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS EML-624 A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS FOR HOMELAND SECURITY PURPOSES Paul Bailey Environmental Measurements Laboratory U.S. Department of Homeland Security 201 Varick Street,

More information

Protecting our Borders while Ensuring Radiation Safety

Protecting our Borders while Ensuring Radiation Safety Protecting our Borders while Ensuring Radiation Safety By Dan A. Strellis Presentation to the Northern California Chapter of the Health Physics Society November 4, 2004 The Mission Objectives of cargo

More information

Detector Configurations for the MAJORANA Demonstrator

Detector Configurations for the MAJORANA Demonstrator Detector Configurations for the MAJORANA Demonstrator Lawrence Livermore National Laboratory UC Berkeley 1 How to determine the best configuration for Majorana? Define a metric reflecting the performance

More information

Domestic Nuclear Detection Office (DNDO)

Domestic Nuclear Detection Office (DNDO) Domestic Nuclear Detection Office (DNDO) Detecting Nuclear Threats 18 November 2008 Thomas McIlvain Architecture Directorate Domestic Nuclear Detection Office Mission and Objectives DNDO was founded on

More information

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl 份有限公司 wwwom 先锋科技股份有限公司 份有限公司 wwwom 先锋科技股份有限公司 www Radiation detection solutions for miniaturized pager and handheld markets sensl: light detection and measurement October - 2009 www.sensl.com 1 Mission

More information

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Portable Alpha/Beta Continuous Online Air Monitor (CAM) Aer 5000 Desktop Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors the ambient air continuously to detect airborne radioactive aerosols (LLRD). Typical application fields are

More information

Detecting and Using Radiation in Security Application

Detecting and Using Radiation in Security Application Detecting and Using Radiation in Security Application Leticia Pibida, Ph.D. leticia.pibida@nist.gov Team members: Fred Bateman, Paul Bergstrom, Heather Chen-Mayer, Jack Glover, Larry Hudson, Ronnie Minniti,

More information

Utilization of advanced clutter suppression algorithms for improved standoff detection and identification of radionuclide threats

Utilization of advanced clutter suppression algorithms for improved standoff detection and identification of radionuclide threats Physical Sciences Inc. VG14-048 Utilization of advanced clutter suppression algorithms for improved standoff detection and identification of radionuclide threats Bogdan R. Cosofret, Kirill Shokhirev and

More information

GEOPHYSICAL ENVIRONMENTAL ANALYSIS EQUIPMENT AND SERVICES

GEOPHYSICAL ENVIRONMENTAL ANALYSIS EQUIPMENT AND SERVICES GENERAL SERVICES ADMINISTRATION Federal Supply Service AUTHORIZED FEDERAL SUPPLY SERVICE SCHEDULE PRICELIST GEOPHYSICAL ENVIRONMENTAL ANALYSIS EQUIPMENT AND SERVICES FSC GROUP: 66, Part II, Section Q FSC

More information

MÖBIUS Recycler. Condensing Liquid Nitrogen HPGe Detector Cooling System

MÖBIUS Recycler. Condensing Liquid Nitrogen HPGe Detector Cooling System Recycler Condensing Liquid Nitrogen HPGe Detector Cooling System All the advantages of Liquid Nitrogen cooling without the need for frequent refilling. Introduction The ORTEC Möbius Recycler technology

More information

The Problems Related to Orphan Radioactive Sources in Scrap Metal (Georgian Experience)

The Problems Related to Orphan Radioactive Sources in Scrap Metal (Georgian Experience) The Problems Related to Orphan Radioactive Sources in Scrap Metal (Georgian Experience) Giorgi Nabakhtiani Nuclear and Radiation Safety Service Ministry of Environment Protection and Natural Resources

More information

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development* Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development* Lodewijk van den Berg and Steven W. Pauly Constellation Technology Corp., 7887 Bryan Dairy Road, Suite 100, Largo, FL

More information

Development of a mobile facility for monitoring of radioactivity in food during an emergency

Development of a mobile facility for monitoring of radioactivity in food during an emergency Development of a mobile facility for monitoring of radioactivity in food during an emergency Commissioned by the Food Standards Agency CEFAS Contract Report RP258 Environment Report RL11/03 Development

More information

Summary. Assessment Methodology

Summary. Assessment Methodology January 2013 System Assessment and Validation for Emergency Responders (SAVER) Summary The U.S. Department of Homeland Security (DHS) established the System Assessment and Validation for Emergency Responders

More information

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1 TacBio: A UV-based Biological Aerosol Detector TacBio Overview-011014 Page 1 TacBio Bio-Aerosol Trigger DoD technology licensed by RI in 2010 Detailed technology transfer: Engineering drawings, circuit

More information

Assessment of factors causing false alarm signals from detection equipment, and ways to mitigate this challenge

Assessment of factors causing false alarm signals from detection equipment, and ways to mitigate this challenge Assessment of factors causing false alarm signals from detection equipment, and ways to mitigate this challenge REPORT by SENIOR RESEARCH FELLOW 12 CSRI OF THE MINISTRY OF DEFENCE OF THE RUSSIAN FEDERATION

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62401 Edition 2.0 2017-12 Radiation protection instrumentation Alarming personal radiation devices (PRDs) for the detection of illicit trafficking of radioactive material INTERNATIONAL

More information

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers... XGLAB X and Gamma Ray Electronics Looking for new frontiers... Research And Development XGLab, spin off company of Politecnico di Milano, the leading Italian technical University, holds a leadership and

More information

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3) FEATURES: REAL TIME - AUTOMATIC CONTINUOUS MONITORING NOT INFLUENCED BY OTHER NUCLIDES NO LIQUID SCINTILLANT REQUIRED EASY CALIBRATION SENSITIVE TO 2,000 pcurie/l Tritium 74 Bq/l NEW STATISTICAL SIGNIFICANCE

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION 12 WEEKS PRINTED RECORD (Optional) 4 CHANNEL

More information

Domestic Nuclear Detection Office (DNDO)

Domestic Nuclear Detection Office (DNDO) Domestic Nuclear Detection Office (DNDO) NDIA Joint CBRN Defense Conference DNDO Overview June 25, 2008 Dr. Chuck Gallaway Deputy Director, DNDO The Radiological and Nuclear Threat Nuclear weapon Improvised

More information

A Continuous Air Monitoring Sampler for 125 I - RIS-125

A Continuous Air Monitoring Sampler for 125 I - RIS-125 A Continuous Air Monitoring Sampler for 125 I - RIS-125 S.Levinson, I.Belaish, T.Kravchik, U.German, O.Pelled, Y. Laichter, Y.Mazor, U.Wengrowicz, E.Dolev, H.Assido, D.Tirosh Nuclear Research Center Negev,

More information

Products & Solutions for Military Customers

Products & Solutions for Military Customers Products & Solutions for Military Customers NUCLEAR MEASUREMENT SOLUTIONS FOR SAFETY, SECURITY & THE ENVIRONMENT U.S. Army photo by Sgt. 1st Class Adelita Mead WWW.CANBERRA.COM Products and Solutions for

More information

Remote Gamma Imaging of High Dose Environments

Remote Gamma Imaging of High Dose Environments Remote Gamma Imaging of High Dose Environments Paul Griffiths Copyright BIL Solutions Ltd 2006. The copyright in this document is wholly vested in BIL Solutions Ltd who reserve all intellectual property

More information

CBRNE solutions to safeguard society.

CBRNE solutions to safeguard society. CBRNE solutions to safeguard society www.smithsdetection.com Protect against CBRNE threats and save lives Government bodies and militaries around the world all face the challenge of protecting themselves

More information

List-mode Data Acquisition a New IEC Standard

List-mode Data Acquisition a New IEC Standard List-mode Data Acquisition a New IEC Standard Harri Toivonen HT Nuclear Oy 13-14 Sep 2016 GammaSpec 2016 Nordic Seminar on Gamma-Ray Spectrometry Rømskog Spa, Vortungen, Rømskog, Norway harri.toivonen@htnuclear.fi

More information

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests INTERNATIONAL STANDARD ISO 3999 Second edition 2004-12-15 Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests Radioprotection Appareils pour

More information

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector N. Tsujimura 1, T. Yoshida 1 and S. Mikami 1 1 Japan Nuclear Cycle Development Institute,

More information

The French experience on nuclear detection architectures and related reachback Laurent OLMEDO

The French experience on nuclear detection architectures and related reachback Laurent OLMEDO The French experience on nuclear detection architectures and related reachback Laurent OLMEDO laurent.olmedo@cea.fr GICNT meeting Ispra 28-30 March 2017 PAGE 1 THE INTERACTION BETWEEN R&D SECURITY AND

More information

SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors

SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors H. Chagani University of Minnesota for the SuperCDMS Collaboration 23 July 2012 The SuperCDMS Soudan Detector: izip interleaved Z-sensitive Ionisation

More information

AERIAL RADIATION DETECTION

AERIAL RADIATION DETECTION DOE/NV/11718--242 AERIAL RADIATION DETECTION September 1999 SPECIAL TECHNOLOGIES LABORATORY Santa Barbara, California DISCLAIMER This report was prepared as an account of work sponsored by an agency of

More information

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes SVG 2 and Probes The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes Innovation with Integrity Defence CBRNE General Specification Alarm thresholds for the dose

More information

safe and your operations compliant

safe and your operations compliant BW Clip Series The most reliable way to keep your workers safe and your operations compliant Easy gas identification with color coded labels and LCD indication: H2S CO O2 SO2 BW Clip Series best maintenance-free

More information