1 Power Controller THV- Series (2,3,,,8, type) THV- General Description s the THV- single phase power control unit can be used with control modes selectable from constant, constant and constant power, it can be used with such heaters as noble metals (Platinum and molybdenum), super Kanthal, and SiC (Silicon Carbide) that have changing resistance in accordance with temperature changes. Optional features like heater break alarm and communication can improve system safety and establishment of a supervisory system. Features Control type selection (Phase-angle/continuous zero-cross/zero-cross) function Detects heater break of non-linear load Ramp-up, Ramp-down Gradient setting Limiter High and Low Base-up Setting (output bias) mode selection (proportional electric power//phase angle) Digital input for uto/manual Constant power control (For phase control only) With the communication function, a connection to a host computer and an MMI is possible. (Protocol: Modbus-RTU) RS-22 or RS-8 converter Max. 3 units Constant control This function maintains the output constant when a load or a power supply fluctuates. It makes the THW Series suitable for heaters of which resistance greatly changes by temperature change, such as Platinum, Molybdenum, Tungsten, and Kanthal heaters. Constant control characteristic diagram 8m 2m m 2m (For phase control only) This function controls the output to make its effective value power proportional to the input. It makes the THW Series suitable for heaters of which resistance gradually increases by temperature or time, such as silicon carbide type heater. This function controls its effective value power at % of the rating shown in the diagram below. From the diagram below, constant power control is expressed as a curve obtained from a line between two points which is a % of the rating of the unit; a point at % x % and a point at % x %. Constant power control characteristic diagram 8 2m m 2m 2 8m m 2 8 Load limiter (For phase control only) This function limits the load value to the heater. The setting range is 3 to % of the rated. (ote) If the load has a large inrush, use soft-start function along with this function to suppress the inrush. This function alone can not prevent the inrush. Current limiter characteristic diagram Limiter set value % 8 2 % 3% % 2% 3% (Rated load) THV_E

2 Power Controller THV- Series Features modes When phase control is selected for linear load (R: resistor), output mode can be selected among Proportional phase angle to input, proportional to input, proportional square (electric power) to input, proportional square feedback to input and constant control. Proportional phase angle to input Phase Effective Electric angle power Proportional to input Proportional square (electric power) to input 8 2 Constant control 2m m 2m 8m (m) (m) (m) Three Types of Control Mode (Selectable) 2 7 Phase control Zero-cross control (Continuous proportion) (Input synchronization system) The wave form of the load power is switched at a desired phase angle q to provide smooth control. Power is switched on and off when the supply is at V. This system suppresses high frequency noise inherent to phase control. Zero-cross control Supply is switched on and off according to the pulse and contact signals from a controller. Input signal OFF O OFF Detects heater break of non-linear load Patent pending Heater break alarm can be used at up to three inflection points in accordance with heater characteristics. The unit can be used with a load with large resistance changes by temperature (e.g. lamp heaters). There is no need of calculation for inflection points as automatic setting is possible. Load () Conventional type Thyristor break-down alarm area Heater break down alarm area Heater characteristics Load () Inflection point (Max.3 points) utomatic setting of inflection points. THV- Thyristor break-down alarm area Heater break down alarm area Memory area In case of a non-linear load, alarm is generated Heater break alarm can be used with even in the normal state. a non-linear load. The THV- stores patterns of heater break alarm settings and enables easy change of settings. Memory area is not available with heater break alarms for non-linear load. rea Maximum load for alarm Heater break alarm set-value Heater break alarm 2 set-value Thyristor break-down alarm set-value Current limiter set-value rea 2 rea Maximum load for alarm Heater break alarm set-value Heater break alarm 2 set-value Thyristor break-down alarm set-value Current limiter set-value Gradient Setting The relation between the setting input and the output can be set. Gradient setting is possible via front keys or an external setter. Control characteristics may vary with the setting as follows.. uto setting input X Internal gradient setting X External gradient setting 2. uto setting input X Internal gradient setting 3. Manual setting X Internal gradient setting X External gradient setting Gradient setting output characteristic diagram Gradient setting THV_E

3 Power Controller THV- Series Features Ramp Function (Soft-start & Soft-down) Even if setting input changes abruptly, output changes slowly to suppress inrush. Ramp-up (Start-up) and ramp down (Start- Down) time can be set in the range of. to 99.9 sec via front keys. % Input signal Soft-start & Soft-down action diagram Soft-start time Soft-down time Time limiter (High & Low) Highest and lowest output values can be set via front keys. High & Low limiter characteristic diagram High limiter 8% Low limiter % Time Base-up setting ( bias) When the setting input is zero, the output can be set via front keys. (Base-up setting is valid when output limiter low is set to.) Base-up output characteristic diagram 8 2 Event input 2 7 Base-up setting : 2% Functions can be assigned to three external contact inputs. Switching of functions can be made externally with contact signals. RU/STOP uto/manual larm interlock reset Heater break alarm : Use/Unuse Soft-up/Soft\down :Use/Unuse Key lock : Use/Unuse Over alarm : Use/Unuse Multi-memory area selection (DI: 2 points) Heater break alarm, over alarm and multi-memory area selection are optional. Heater break alarm This function measures load and compares it with a heater break alarm set value. larm will be activated if the load goes into alarm ranges. Maximum two alarm set points can be set for the heater break alarm, which could be used for heater-deterioration alarm and heater-break alarm. (ote) For phase control, heater break alarm does not work when the load is less than % of maximum load. limiter High at start-up This function limits the highest output for the period of a preset time after power-o and control mode change from Stop to Run. It makes the THV- Series suitable for heaters which cause rush flow, such as Halogen lamp, Tungsten, Platinum, and Molybdenum heaters. 8 High limiter 8% 2 Soft start High limiter output at the time of start Over- alarm Soft start the time of start % The alarm goes on when the load exceeds 2% of the rated. The alarm types are Power supply abnormal, Power frequency abnormal, Board alarm, Over alarm, Fuse break alarm, Thyristor break alarm, and Heater break alarm. will go on, when any of them goes in alarm status. (larm logic selection, : 2 points) THV_E 3

4 Power Controller THV- Series Specifications Maximum Load Current 2 C, 3 C, C, C, 8 C, C, C, 2 C Control Method Phase control, Zero-cross control (Selectable) pplicable Load Phase control : Linearity (R:Resistor) load, Control of primary side of a transformer (magnetic field density 8, gauss or less) Zero-cross control : Linearity (R:Resistor) load Input Signal Group (Field-programmable within Group) Current input to 2m DC (Input impedance : Ω ) Current input to 2m DC (Input impedance : Ω ) Voltage input to V DC (Input impedance : 3kΩ ) Voltage input to V DC (Input impedance : 3kΩ) Voltage pulse input /2V DC (Input impedance : 3kΩ ) on- contact input Group 2 (Field-programmable within Group) Voltage input to V DC (Input impedance : kω) Voltage pulse input /2V DC (Input impedance : kω ) Voltage pulse input /2V DC (Input impedance : kω ) on- contact input a) Current input to 2m DC (Input impedance : Ω ) b) Voltage input to V DC (Input impedance : 3kΩ) c) Voltage input to V (Input impedance : 8kΩ) d) Voltage pulse input /2V DC (Input impedance : 3kΩ) e) on- contact input (Input impedance : 7Ω) mode a) Constant control b) Proportional phase angle Proportional Proportional square Proportional square feed back [when phase control is selected for linearity load (R: resistor)] c) Constant control d) Constant power control a), b) : Standard function, c), d) : Optional function Input sampling cycle. cycle of power cycle Minimum Load Current. (at 98% output of rated ) Voltage Range to 98% of rated Power OFF leakage 2, 3,, 8 C type 27m C rms or less (load 2V rms, Hz, Ta=2ºC), 2 C type 9m C rms or less (load 2V rms, Hz, Ta=2ºC) Power Supply Voltage 9 to 2V C (Including power supply variation) [Rating : to 2V DC] Power Frequency /Hz (utomatic discriminating) llowable Power Frequency Variation Hz±Hz, Hz±Hz,(Performance guarantee range) to.9hz (Hz), to.9hz (Hz) (Operating guarantee range) llowable mbient Temperature Performance guarantee range: to +ºC ( type : to +ºC) Operating guarantee range: - to +ºC (2,3,,,8, type) - to +ºC (,2 type) Operating ambient humidity to 9%RH (on-condensing) bsolute humidity : MX.W.C 29.3g/m 3 dry air at.3kpa Cooling method 2, 3,, 8 C type : atural convection, 2 C type : ir cooling (Built-in cooling fan) Dielectric Between main circuit terminals, power terminals and heat sink 2V C for one minute. Between main circuit terminals, power terminals and input terminals 2V C for one minute. Insulation resistance Between main circuit terminals, power terminals and heat sink 2MΩ or more (V DC) Between main circuit terminals, power terminals and input terminals 2MΩ or more (V DC) Mounting Method Vertical mounting Weight pprox..kg (2, 3), pprox..kg (, ) pprox. 2.kg (8, ), pprox..kg (, 2), Power consumption 2, 3,, 8 C type Less than V (at V C), Rush or less Less than 8V (at 2V C), Rush 2 or less, 2 C type Less than V (at V C), Rush 22 or less Less than 22V (at 2V C), Rush 2 or less Self-diagnostic function Check item a) Data check, Back-up check, Power frequency check, Main circuit power supply check, /D converter check b) Power supply check, Watch dog-timer ction at abnormality : Check item a) : Control stop, Board abnormality lamp O, Thyristor output OFF Check item b) : ction stop, lamp O, Thyristor output OFF Setting Range Gradient setting :. to 2.% [Front key], to % [External setting unit] limiter (High) :. to.% [Front key] limiter (Low) :. to.% [Front key] limiter at start-up (High) :. to.% [Front key] limiter time at start-up (Low) :. to. sec [Front key] Base-up setting ( bias) Manual setting : -. to.% [Front key] :. to % [Front key] to % [External setting unit] Standard functions uto/manual selection (External manual setting unit is optional) Gradient setting (External setting unit is optional) Soft-up/Soft-down :. to.sec Digital input (DI) : 3 points, on- contact input RU/STOP, uto/manual, larm interlock reset Heater break alarm : Use/Unuse, Soft-up/Soft\down :Use/Unuse Key lock : Use/Unuse, Over alarm : Use/Unuse Multi-memory area selection (For heater break alarm) (Selectable) O/OFF control (External setting units are optional) Option function : 2 points Open collector output, 2V C, (Resistive loaf) Energized/De-energized is selectable. (Heater break alarm, Thyristor break alarm, Fuse break alarm, Power supply abnormal, Power frequency abnormal, Over alarm, Board alarm) * Selectable Heater break alarm Current measuring accuracy : ±2% of rated load umber of alarm delay times : to 99 times Memory area : areas Load limiter Setting range :. to 22. (2 type),. to 33. (3 type). to. ( type),. to. ( type). to 88. (8 type),. to. ( type). to. ( type),. to 22. (2 type) Heat sink temperature abnormality *, 2 type: Standard function function method : RS-8 (2-wire, half-duplex) RS-22 (-wire, half-duplex) Synchronous method : Start-stop synchronous type speed : 9 bps Protocol : Modbus-RTU Data format : Start bit :, Data bit : 8, Parity bit : one Stop bit : Maximum connection : 3 units Compliance with Standards (2, 3,,, 8, C Type) UL : UL-, cul : C/CS-C22.2 o.- CE marking : LVD : E- OVERVOLTGE CTEGORYII, POLLUTIO DEGREE 2, EMC : E97--3 specified noise filter must be used SOSHI ELECTRIC CO., LTD HF23-UP (2,3), HF2-UP () Table of Stability Function Constant variation Constant variation Constant power variation HF2-UP (), HF2-UP () Table of internal calorific value Rated load () Internal calorific value (W) Operating condition Power supply variation : Within ±% Load variation : 2 times Power supply variation : Within ±% Load variation : 2 times Power supply variation: Within ±% Load variation : 2 times HF28-UP (8) Stability Within ±2% of input Within ±2% of rated Within ±% of rated power THV_E

5 Power Controller THV- Series Rated load : 2,3,,,8, C Specifications Model and Suffix Code Type THV- PZ Power supply Single phase to 2V C Control method Phase control/zero-cross control (programmable, default: phase control) PZ 2 C 3 C Rated load C C 8 C C to V DC * to V DC to V DC to 2m DC to 2m DC Standard + Constant control Standard + Constant control + Constant control mode *2 (with heater break alarm, thyristor break down alarm, memory area load limiter and over alarm) Standard + Constant control + Constant power control (with heater break alarm, thyristor break down alarm, memory area load limiter and over alarm) Fast-blow fuse o fast-blow fuse With fast-blow fuse o alarm output 2 points Heat sink temperature o function detection function/ Heat sink temperature detection function on-linear resistance on-linear resistance heater break alarm heater break alarm When the output mode is specified to E or W code, this alarm can be selected. (RC-HB) Heat sink temperature detection function + on-linear resistance heater break alarm When the output mode is specified to E or W code, this alarm can be selected. ccessories *3,* o communication RS-22 RS-8 Setter (Volume, knob, Scale plate) unit + Connector for input (Plug) Setter (Volume, knob, Scale plate) 2 units + Connector for input(plug) Connector for input (Plug) Connector for alarm output (Plug) Rated load : 2,3,,,8, C Specifications Model and Suffix Code Type THV- PZ Power supply Single phase to 2V C Control method Phase control/zero-cross control (programmable, default: phase control) PZ Rated load C 2 C to V DC * to V DC to V DC to 2m DC to 2m DC Standard + Constant control Standard + Constant control + Constant control mode *2 (with heater break alarm, thyristor break down alarm, memory area load limiter and over alarm) Standard + Constant control + Constant power control (with heater break alarm, thyristor break down alarm, memory area load limiter and over alarm) Fast-blow fuse o fast-blow fuse With fast-blow fuse o alarm output 2 points Heat sink temperature detection function/ Heat sink temperature detection function on-linear resistance Heat sink temperature detection function + on-linear resistance heater break alarm heater break alarm When the output mode is specified to E or W code, this alarm can be selected. (RC-HB) Model and Suffix Code o communication RS-22 RS-8 Setter (Volume, knob, Scale plate) unit + Connector for input (Plug) Setter (Volume, knob, Scale plate) 2 units + Connector for input(plug) Connector for input (Plug) ccessories *3,* Connector for alarm output (Plug) * : is programmable within group. When contact input is required, specify the connector for input as an accessory (Either of -, -2, or -9). Group to 2m DC to 2m DC to V DC to V DC Voltage pulse /2V DC on- contact Group 2 to V DC Voltage pulse /2V DC Voltage pulse /2V DC on- contact *2 : Standard output mode : Proportional phase angle Proportional Proportional square. *3 : Setters are for external gradient setting, external manual setting, and external high/low setting for on/off control. Use two units of setter in the following cases; When external gradient setting and external manual setting are required. High/low setting for on/off control is used. * : It is possible to specify more than one accessories by adding suffix code at the end. Example: --B : Setter (Volume, knob, Scale plate) unit + Connector for input (Plug) + Connector for alarm output (Plug) and -- cannot be specified simultaneously. THV_E E W E W F F B C C B B

6 Power Controller THV- Series External Dimensions 2, 3,, type Mounting dimension Unit : mm Install the instrument as illustrated in the drawing to increase the cooling effect. 98 B * B 2,3, M 8, type mbient temperature ( C ) * -M, 2 type 2 87±.2 More than More than 2 More than Mounting dimension Temperature characteristics of load Load : 2, 3,, 8,,, 2 type : type 82±.2 8±.2 More than 2 Mounting dimension The front of the instrument can be opened to allow replacement of the fast-blow fuse. When installing the instrument, leave enough space to allow the cover to be opened. 22±.2 More than 9 28 * -M 93±.2 More than 2 C C 2,3, 8, ,2 322 * : Length includes that of an optional connector, but space for wiring to connector is not included. THV_E

7 Power Controller THV- Series External Wiring Display Set keys Main circuit terminal V C-2V L to 2m, to 2m input to V, to, to V and pulse input + V - + V Input connector connector port Indication lamp Input and power supply terminal Main circuit terminal Power supply to 2V C D 2/T /L Load (Heater) * Make sure the wiring of the main circuit (2/T,/L) and the power supply (,) are in the same phase. If the wiring is out of phase, the instrument will not produce normal output. Terminals size Short Terminals size o. T,L Item 2/3 / 8/.3mm or.mm or 8.mm or more more more 9.mm or 3.2mm or 22.mm or D (mm) less less less Controller to 3.2mm or more.mm or less D Short Controller 3.2mm or more D (mm) Contact.mm or input less Indication Lamp IDICTIO LMP Lamp THY_B Contents (Self-diagnostic abnormality) Power frequency abnormality Board abnormality Power supply abnormality Heater break alarm SV Heater break alarm SV2 Thyristor break alarm Over alarm Fuse break alarm Heat sink temperature abnormality * Up to two alarm set points can be set for the heater break alarm. * Fuse break alarm lamp is available when a fast blow fuse with fuse break alarm output is used. Connector Input connector Pin o connector * Connector (Plug side) is optional. Contents +V (Gradient setting input) V (Gradient setting input) Gradient setting input ( to V input by gradient setter) +V (Manual setting input) V (Manual setting input) Manual setting input ( to V input by manual setter) External contact input (DI) External contact input 2 (DI2) External contact input 3 (DI3) V (External input) V (External input) V (External input) Pins -2 are internally connected. Pin o. Contents Digital output (DO) : Relay contact output 2 Digital output 2 (DO2) : Relay contact output 3 COM : Common uto setting (With gradient setter) Gradient setter uto/manual setting selection (With gradient setter) Manual setting (With manual setter) Gradient Input connector Input connector setter Input connector Input connector Manual setter Manual setter Manual setter Close : Manual setting Open : uto setting Close : Manual setting Open : uto setting * uto/manual selection is assigned to DI * uto/manual selection is assigned to DI External contact input Input connector External input (DI) External input 2 (DI2) External input 3 (DI3) External contact input can be assigned from function below. RU/STOP uto/manual larm interlock reset Heater break alarm function : Use/Unuse Soft start : Use/Unuse Key lock : Use/Unuse Over alarm : Use/Unuse Memory area selection (DI 2 points) larm larm 2 connector Power supply THV_E 7

8 Power Controller THV- Series ccessories Gradient setter, Manual setter, High/Low setter : THVP-S φ2.8 8 Unit : mm φ φ.8 φ. 8.7 Volume (Resistance:kΩ,B) Scale plate Knob RS-22 cable Model Code : W-BF-2- (.m) W-BF-2- (m) W-BF-2-3 (3m) Termination resistor connector Model : W-BW- (For RS-8) Model : W-BW-2 (For RS-22) pins pins RS-22 W-BF-2- RS-22 W-BF-2- COM- Termination resistor W-BW-2 Model code * Please refer to the following codes to order accessories. ame Model Code Setter THVP-S Input connector (plug) connector (plug) THWP-C THVP-C ame Fast-blow fuse 2 3 * 8 * * 2 * Model Code THVP-F2 THVP-F3 THVP-F THVP-F THVP-F THVP-F (2 pieces) (2 pieces) THVP-FB (2 pieces) THVP-FC (2 pieces) * : fast-blow fuse for 8 uses two rapid blow fuses (THVP-F). fast-blow fuse for uses two rapid blow fuses (THVP-F). fast-blow fuse for, 2 uses two rapid blow fuses (:THVP-FB, 2:THVP-FC3). Fast-blow fuse can replace from the front. 8 THV_E

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

Three-phase Thyristor Unit. 200 V AC Type THW-A1. Instruction Manual IMR02R01-E1 RKC INSTRUMENT INC.

Three-phase Thyristor Unit. 200 V AC Type THW-A1. Instruction Manual IMR02R01-E1 RKC INSTRUMENT INC. Three-phase Thyristor Unit 200 V AC Type THW-A1 Instruction Manual RKC INSTRUMENT INC. IMR02R01-E1 Company names and product names used in this manual are the trademarks or registered trademarks of the

More information

JW SERIES. Three Phase Thyristor Regulator PSE-351

JW SERIES. Three Phase Thyristor Regulator PSE-351 JW SERIES Three Phase Thyristor Regulator JW Series is compact lightweight three-phase control thyristor regulators enabling high-density instrumentation. The methods of control are divided into two ways,

More information

Three-phase Thyristor Unit. 400 V AC Type THW-A4. Instruction Manual IMR02R02-E2 RKC INSTRUMENT INC.

Three-phase Thyristor Unit. 400 V AC Type THW-A4. Instruction Manual IMR02R02-E2 RKC INSTRUMENT INC. Three-phase Thyristor Unit 400 V AC Type THW-A4 Instruction Manual RKC INSTRUMENT INC. IMR02R02-E2 Company names and product names used in this manual are the trademarks or registered trademarks of the

More information

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection SA00 SA00 SA00 SA00 Temperature Limit ontroller SA00L FM APPROVED SA00L General Description The SA00L is a FM approved high limit or low limit controllers. The SA00 is a socket mounting type temperature

More information

General Specifications

General Specifications General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

M2000 Engine Controller

M2000 Engine Controller M2000 Engine Controller Integrated control and protection of diesel and gas engines for all purposes Especially suited for auxiliary generator sets 1 IN OPERATION 1 2 STARTFAIL 2 3 OVERSPEED RPM FAIL 3

More information

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Instruction manual for DIN rail mounting type indicating controller DCL-33A Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

Instruction manual Temperature Controller KT7

Instruction manual Temperature Controller KT7 Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

Instruction manual Micro-computer based digital indicating controller

Instruction manual Micro-computer based digital indicating controller Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY

More information

Advanced Ultraviolet Burner Controller

Advanced Ultraviolet Burner Controller No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1- DPR-45 User Manual V-2.0 (2..206) DPR-45 TEMPERATURE PROTECTION RELAY PT00 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT 9-50VDC SUPPLY DESCRIPTION DPR-45 is a precision unit designed for the temperature

More information

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER MODEL AL3 7 5 - AL3000 series conforming to CE, UL and CSA are 100mm multi-point type hybrid recorders with a simultaneous display of multi-channel

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

GCS-300 No.GCS31E

GCS-300 No.GCS31E INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

/8 DIN Level Indicator

/8 DIN Level Indicator Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...

More information

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS... SECTION Table of Contents SECTION 1 INTRODUCTION...................... 1.1 Description............................... 1.2 Features................................. 1.3 Models..................................

More information

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction Series SHR-5620 Digital Display Volumetric Meter Operation Instruction Version: 5620-110722 1. Introduction SHR-5620 Digital Display Volumetric Meter,Produced by full-automatic chip mounter with surface

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment

More information

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 505 Grünberg Tel.: 060 807-0 Fax: 060 807-59 A-ISOMETER IRDH575 Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with

More information

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2 Series 21 - Specifications INDEX Description Page Operational Specification 2 Analog Operational Specification - Communications Options 3 Digital Operational Specification - Communications Options 4 Hardware

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy

More information

Stellar Panelboard Dimming Systems

Stellar Panelboard Dimming Systems create a new dimension in lighting control. While lighting systems consume energy, Stellar dimming panels conserve and redirect energy into the atmosphere of your facility. The panel s universal dimmers

More information

General Specifications

General Specifications General Specifications Model OX400 Low Concentration Zirconia Oxygen Analyzer The OX400 is a highly accurate and reliable low-concentration zirconia oxygen analyzer that is capable of measuring a wide

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal User s Manual Model VJA Distributor (Multi-function) (Isolated Single-output and Isolated Dual-output Types) --3, Naka-cho Musashino-shi, Tokyo 180-80 Japan Thank you for purchasing the JUXTA Signal Conditioner.

More information

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0 User s Manual Model VJH Isolator (Multi-function) (Isolated Single-output and Isolated Dual-output Types) --, Naka-cho Musashino-shi, Tokyo 80-80 Japan Thank you for purchasing the JUXTA Signal Conditioner.

More information

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS WITH INTERCONNECT Data Sheet 60.6 NO CONNECT. I / O LOW-V SET NO CONNECT. LED + SUPPLY TIMING RES. FEEDBACK 3 4 5 6 7 NC NC LOGIC OSC. & TIMING DRIVER 0 6 5 4 3 8 V SS GUARD DETECT. IN GUARD SENSITIVITY

More information

7EF/7HF/7EC/7ES Temperature Controllers

7EF/7HF/7EC/7ES Temperature Controllers 7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification

More information

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC. High Resolution Temperature Controller REX-F9000 Instruction Manual RKC INSTRUMENT INC. IM9000F01-E5 All Rights Reserved, Copyright 1999, RKC INSTRUMENT INC. Thank you for purchasing this RKC product.

More information

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,

More information

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation

More information

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations

More information

Example of Applications and Parameter Functions

Example of Applications and Parameter Functions PX-series digital temperature controller Example of Applications and Functions ECNO:1158 I. Example of Applications 1 Controlling both heating and cooling with a single controller Only one controller is

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad. INSTRUCTI MANUAL (EXCERPT) Digital Indicating Controller ACS-13A- /A (For Use with the Infrared Temperature Sensor RD-500) No.ACS11AE1 2011.07 The digital indicating controller ACS-13A /A is an exclusive

More information

LC1350 Level Controller

LC1350 Level Controller LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax TC-324B Manual, Rev. 05.01.31 Single Channel Heater Controller Model TC-324B 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax TC-324B Manual, Rev. 05.01.31 TC-324B

More information

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02 CHILLGARD M-100 Refrigerant Sensor Operating Manual GB Order No.: 10086391/02 For the Declaration of Conformity, please visit the product page on MSAsafety.com. MSA Europe GmbH Schlüsselstrasse 12 8645

More information

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES Data Sheet 260.8 TIMER START I / O LOW-V SET TIMER OUT + SUPPLY TIMING RES. FEEDBACK 2 3 4 5 6 7 V DD LOGIC OSC. & TIMING DRIVER 8 V SS 9 ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS ) Supply

More information

Pump-Up Controller MODEL 4062

Pump-Up Controller MODEL 4062 Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up

More information

ELITE-600 DENTAL PORCELAN FURNACE

ELITE-600 DENTAL PORCELAN FURNACE ELITE-600 DENTAL PORCELAN FURNACE USER MANUAL CONTENTS Introduction. 2 Specifications 3 Description of the furnace 4 General. 5 Controls 5 display 5 Data display.. 5 Vacuum display... 5 Parameter leds..

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

ELECTRONIC HUMIDISTAT: H270

ELECTRONIC HUMIDISTAT: H270 ELECTRONIC HUMIDISTAT: H0 ONE OR TWO STAGES HUMIDITY SUPPLY OUTDOOR TEMPERATURE RESET DESCRIPTION The H0 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

TCN Series. Economical Dual Display Type, PID Control. Economical Dual Display Type, PID Control Features. Ordering Information.

TCN Series. Economical Dual Display Type, PID Control. Economical Dual Display Type, PID Control Features. Ordering Information. TCN eries Economical Dual Type, PID Control Economical Dual Type, PID Control Features Realizes ideal temp. controlling with newly developed PID control algorithm and 100ms high speed sampling Built-in

More information

4TEMPERATURE CONTROLLER

4TEMPERATURE CONTROLLER Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and

More information

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR Solid State Relays SOLITRON MIDI Current Sensing Type, R AC semiconductor contactor Integrated current monitoring Zero switching (1A) Direct copper bonding (DCB) technology LED-indication Cage clamp output

More information

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput User s Manual Model VJS Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) --, Naka-cho Musashino-shi, Tokyo 80-80 Japan You can download the latest manuals

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

Pump-Down Controller MODEL 4052

Pump-Down Controller MODEL 4052 Pump-Down Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4052 Pump-Down

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

LINEAR HEAT DETECTION CABLE DURÁN-SAFE LINEAR HEAT DETECTION CABLE DURÁN-SAFE Installation & User Manual 2018 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com I-manSAFECABLE-v05 TABLE OF CONTENTS Pages 1. INTRODUCTION...

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5 Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor Function Analysis

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this

More information

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

Zone Terminal, 2-fold, FM MT/U , GH Q R0111 , GH Q631 0060 R0111 SK 0001 B 01 The zone terminal is used for the monitored connection of detectors from security techlogy on the EIB. The device is installed in conventional switch boxes (Ø 55 mm).

More information