TCN Series. Economical Dual Display Type, PID Control. Economical Dual Display Type, PID Control Features. Ordering Information.

Size: px
Start display at page:

Download "TCN Series. Economical Dual Display Type, PID Control. Economical Dual Display Type, PID Control Features. Ordering Information."

Transcription

1 TCN eries Economical Dual Type, PID Control Economical Dual Type, PID Control Features Realizes ideal temp. controlling with newly developed PID control algorithm and 100ms high speed sampling Built-in relay output or R drive output selectable : Enables to phase control and cycle control with R drive output (RP function) Dramatically increased visibility using wide display part Enhanced convenience of wiring and maintenance by connector plug type (TCN4- -P) Mounting space saving with compact design : pprox. 38% reduced size compared with existing model (depth-based) Ordering Information T CN R P DIN W48 48mm ize M DIN W72 72mm DIN W48 96mm L DIN W96 96mm Digit (4digit) etting type CN Dual display type, set by touch switch Item T controller 1: Only for TCN4 model. 2: In case of the C voltage model, R drive output method (standard / control, cycle control, phase control) is available to select. pecifications eries TCN4 TCN4M TCN4 TCN4L Power C power VC 50/60z supply C/DC power 24VC 50/60z, 24-48VDC llowable voltage range 90 to 110% of rated voltage Power C power Max. 5V ( VC 50/60z) consumption C/DC power Max. 5V (24VC 50/60z), Max. 3W (24-48VDC) method 7 egment (: red, V: green), Other display (green, red) LED Character size Input type Power supply uxiliary output Wiring method No-mark Bolt wiring method P Connector plug connection method 1 Control output R Relay contact output+r drive output VC 50/60z, 24-48VDC VC 50/60z 2 larm1+larm2 output (W ) mm mm mm mm V (W ) mm mm mm mm RTD DPt100Ω, Cu50Ω (allowable line resistance max. 5Ω per a wire) Thermocouple K (C), J (IC), L (IC), T (CC), R (PR), (PR) RTD t room temperature (23 ±5 ): ( ±0.5% or ±1, select the higher one) ±1digit accuracy 1 Out of room temperature range: ( ±0.5% or ±2, select the higher one) ±1digit Thermocouple For TCN4- -P, add ±1 by accuracy standard. Control Relay 3 1a output R 12VDC ±2V 20m Max. larm output L1, L2 Relay output: 1 1a Control method / control, P, PI, PD, PID control ysteresis 1 to / (0.1 to 50.0 / ) variable 1: t room temperature (23 ±5 ) Thermocouple R (PR), (PR), below 200 : ( ±0.5% or ±3, select the higher one) ±1digit Thermocouple R (PR), (PR), over 200 : ( ±0.5% or ±2, select the higher one) ±1digit Thermocouple L (IC), RTD Cu50Ω: ( ±0.5% or ±2, select the higher one) ±1digit Out of room temperature range Thermocouple R (PR), (PR), below 200 : ( ±1.0% or ±6, select the higher one) ±1digit Thermocouple R (PR), (PR), over 200 : ( ±0.5% or ±5, select the higher one ±1digit Thermocouple L (IC), RTD Cu50Ω: ( ±0.5% or ±3, select the higher one) ±1digit For TCN4- -P, add ±1 by accuracy standard. Line-up Connector plug type (TCN4- -P) -41 () ockets () Rs / Power peed / Pulse ensor witching upplies tepper Motors & s () oftware

2 TCN eries pecifications eries TCN4 TCN4M TCN4 TCN4L Proportional band 0.1 to / Integral time 0 to 9999 sec. Derivative time Control period 2: The weight includes packaging. The weight in parentheses is for unit only. Environment resistance is rated at no freezing or condensation. Connections 0 to 9999 sec. 0.5 to sec. Manual reset 0.0 to 100.0% ampling period 100ms Dielectric C Power 2,000VC 50/60z 1min. (between input terminal and power terminal) strength C/DC power 1,000VC 50/60z 1min. (between input terminal and power terminal) Vibration 0.75mm amplitude at frequency of 5 to 55z in each X, Y, Z direction for 2 hours Mechanical OUT: Over 5,000,000 times, L1/2: Over 5,000,000 times Relay life cycle Electrical OUT: Over 200,000 times ( 3 resistive load) L1/2: Over 300,000 times ( 1 resistive load) Insulation resistance Min. 100MΩ (at 500VDC megger) Noise resistance ±2kV R-phase, -phase the square wave noise (pulse width: 1us) by the noise simulator Memory retention pprox. 10 years (when using non-volatile semiconductor memory type) Environment mbient temperature -10 to 50, storage: -20 to 60 mbient humidity 35 to 85%R, storage: 35 to 85%R Insulation type Double insulation or reinforced insulation (mark:, Dielectric strength between the measuring input part and the power part: C power 2kV, C/DC Power 1kV) pproval Weight 2 pprox. 147g (pprox. 100g) pprox. 203g (pprox. 133g) pprox. 194g (pprox. 124g) pprox. 275g (pprox. 179g) TCN4 eries has selectable control output; Relay output, and R drive output. C/DC voltage type does not have RP function. TCN4 TCN4- -P R OUT: 12VDC ±2V 20m Max. OURCE: VC 5V 50/60 z, 24VC 5V 50/60 z, 24-48VDC 3W L1 OUT: 1 1a L2 OUT: 1 1a Relay OUT: 3 1a B' B RTD TC ENOR R OUT: 12VDC ±2V 20m Max. Relay OUT 3 1a 1 OURCE: VC 5V 50/60 z, 24VC 5V 50/60 z, 24-48VDC 3W L1 OUT 1 1a L2 OUT 1 1a B' B RTD TC TCN4M R OUT: 12VDC ±2V 20 m Max. 1 OURCE: VC 5V 50/60 z, 24VC 5V 50/60 z, 24-48VDC 3W Relay OUT: 3 1a L1 OUT: 1 1a L2 OUT: 1 1a 1: Power supply C power: VC 5V 50/60z C/DC power: 24VC 5V 50/60z, 24-48VDC 3W B' RTD TC B ENOR TCN4/L R OUT: 12VDC ±2V 20 m Max. 1 OURCE: VC 5V 50/60 z, 24VC 5V 50/60 z, 24-48VDC 3W L1 OUT: 1 1a L2 OUT: 1 1a Relay OUT: 3 1a B' RTD TC B ENOR -42

3 Economical Dual Type, PID Control Dimensions (unit: mm) TCN4 TCN4- -P () TCN4M TCN ockets () Rs / Power TCN4L cut-out D B C peed / Pulse Bracket TCN4 eries TCN4M, TCN4, TCN4L eries ize B C D eries TCN4 Min. 65 Min TCN4M Min. 90 Min TCN4 Min. 65 Min TCN4L Min. 115 Min ensor witching upplies tepper Motors & s () oftware

4 TCN eries Dimensions (unit: mm) Terminal cover (sold separately) R-COVER (48 48mm) RM-COVER (72 72mm) 70 3 R-COVER (48 96mm) RL-COVER (96 96mm) Unit Description 4. uto tuning indicator: T indicator flashes by every 1 sec during operating auto tuning. 5. key: Used when entering into parameter setting group, returning to RUN mode, moving parameter, and saving setting values. 6. djustment: Used when entering into set value change mode, digit moving and digit up/down. 7. Digital input key: Press + keys for 3 sec. to operate the set function (RUN/TOP, alarm output reset, auto tuning) in digital input key [DI-K]. 8. unit ( / ) indicator: It shows current temperature unit. V etting You can set the temperature to control with keys. etting range is within V lower limit value [L-V] to V higher limit value [-V]. E.g.) In case of changing set temperature from 210ºC to 250ºC 1RUN mode 1. Present temperature () display (red) RUN mode: Present temperature () display. Parameter setting mode: Parameter display. 2. et temperature (V) display (green) RUN mode: et temperature (V) display. Parameter setting mode: Parameter setting value display. 3. Control/larm output display indicator OUT: It turns when the control output is. During R drive output type in CYCLE/PE control, this indicator turns when MV is over 3.0%. (only C voltage type) L1/L2: It turns when the alarm output is. 2V setting mode Press any key among,,, once. Change V by,, keys 3Completes V setting 4Check V -44

5 Economical Dual Type, PID Control Parameter Group () Run mode Press any key among,,, 2 sec. 4 sec. V setting Parameter group 1 Parameter group 2 PR1 PR2 L1 alarm temperature L2 alarm temperature Input sensor unit Input correction Input digital filter L1 IN-Tㅑㅜ UNIT IN-Bㅑㅜ MvF L2 uto tuning T Proportional band P Control type C-MD Control output type Control output operation O-FT R drive output method 1 V highlimit value -V Control cycle V lowlimit value L-V L1 alarm operation mode OUT rm T L-1 ockets () Rs / Power Integral time I Derivative time D Manual reset RET detection band LBa ㅠ B Digital input key monitoring time LBaT Control output MV in case of input break error larm output hysteresis Y Parameter lock DI-K ErMV LOC L2 alarm operation mode L-2 peed / Pulse ensor ysteresis Y 3 sec. 3 sec. Press key over 3 sec in any setting group, it saves the set value and returns to RUN mode. (Press key once in V setting, it returns to RUN mode). If no key entered for 30 sec., it returns to RUN mode automatically and the set value of parameter is not be saved. Press key again within 1 sec. after returning to RUN mode, it advances of the first parameter of previous setting group. Press key to move next parameter. This parameter might not be displayed depending on other parameter settings. et parameter as 'Parameter group 2 Parameter group 1 etting of set value' order considering parameter relation of each setting group. 1: It is not displayed for C/DC power model (TCN4-22R). witching upplies tepper Motors & s () oftware -45

6 TCN eries Parameter Group 1 3 sec. Run mode PR1 L1 alarm temperature L1 2 sec : : Press any key among,,. 2: fter checking or changing setting value in each parameter, press key to save and move to next parameter setting. 3: It is displayed when control type parameter [C-MD] of parameter group 2 is set PID. Press key for 3 sec. to return RUN mode at any parameter. This parameter might not be displayed depending on other parameter settings. etting range: Deviation alarm (-F. to F.), bsolute value alarm (temperature range) In case alarm operation mode [L-1] of Parameter group 2 is M)_/Ba /B, no parameters is displayed. L2 alarm temperature L2 3 uto-tuning T 1250 etting range: Deviation alarm (-F. to F.), bsolute value alarm (temperature range) In case alarm operation mode [L-2] of Parameter group 2 is M)_/Ba /B, no parameters is displayed. Front T indicator flashes during auto tuning operation. Proportional band P 01)0 etting range: 0.1 to / Integral time I 0000 etting range: 0 to 9999 sec. Integral operation is when set value is "0". Derivation time D 0000 etting range: 0 to 9999 sec. Derivative operation is when set value is "0". Manual reset RET 05)0 etting range: 0.0 to 100.0% It is displayed in P, PD control. ysteresis Y 002 etting range KCa, JIc, LIc, TCc, RPR, RP, DPt, CUs: 1 to / KCaL, JIcL, LIcL, TCcL, DPtL, CUsL: 0.1 to 50.0 / It is displayed when control type [C-MD] of parameter group 2 is set OF. Parameter Group 2 Run mode 3 sec. 4 sec. PR2 1: : Press any key among,,. 2: fter checking or changing setting value in each parameter, press key to save and move to next parameter setting. 3: It is displayed when control type parameter [C-MD] of parameter group 2 is set PID. Press key for 3 sec. to return RUN mode at any parameter. This parameter might not be displayed depending on other parameter settings. Input sensor 1 IN-T KCa KCaL CUsL 2 etting range: Refer to 'Input sensor and temperature range'. If changing input sensor, V, IN-B, -V, L-V, L1, L2, LBaT, LBaB, Y parameter values are initialized. unit UNIT?C?F If changing temperature unit, V, IN-B, -V, L-V, L1, L2, LBaT, LBaB, Y parameter values are initialized. Input correction IN-B 0000 Input digital filter MvF 00)1 etting range KCa, JIc, LIc, TCc, RPR, RP, DPt, CUs: -999 to 999 / KCaL, JIcL, LIcL, TCcL, DPtL, CUsL: to / etting range: 0.1 to 120.0sec. et input digital filter time for average input value affected control, and display value. -46

7 Economical Dual Type, PID Control V low-limit value L-V V high-limit value -V Control output operation O-FT ET etting range: Within the rated temperature range by input sensor [L-V (-V-1digit)] When changing V low-limit value, if V<L-V, V is initialized as L-V. In case of changing input sensor type [IN-T], it changes automatically as min. value of the changed input sensor. etting range: Within the rated temperature range by input sensor [-V (L-V+1digit)] When changing V high-limit value, if V>-V, V is initialized as -V. In case of changing input sensor type [IN-T], it changes automatically as max. value of the changed input sensor. COOL When changing control output operation, ErMV is initialized. () Control type C-MD PID OF When changing control type, ErMV is initialized (control output MV is below 100%) and DI-T turns automatically. Control output type OUT RLY R R drive output method rm TND CYCL P It is displayed when selecting control output [OUT] as R. It is not displayed for C/DC power model (TCN4-22R). ockets () Control cycle T 02)0 etting range: 0.5 to 120.0sec. In case of Relay output [RLY] of control output [OUT] it is set as 20.0 sec. In case of R drive output [R] of that, it is set as 2.0 sec. T is not displayed when R drive output [rm] method is set as CYCL, P. Rs / Power L1 alarm operation mode L-1 M! L2 alarm operation mode L-2 M@ peed / Pulse larm output hysteresis Y monitoring time LBaT detection band LBaB Digital input key DI-K Control output MV in case of input break error ErMV TOP 00)0 For more details refer to Functions ' larm'. Black: Flashes, Gray: Fixed When changing L1, L2 alarm operation mode, L1, L2 alarm temperature value are initialized. Refer to Functions ' larm output hysteresis'. Y is not displayed when L1, L2 alarm operation mode [L-1, L-2] is set as M)_, Ba, LBa. etting range: 0 to 9999 sec. '0' is set, loop break alarm function is. LBaT is displayed when L1, L2 alarm operation mode [L-1, L-2] is set as LBa. etting range: 0 to 999 (0.0 to 999.9) / '0' is set, loop break alarm function is. LBaB is displayed when L1, L2 alarm operation mode [L-1, L-2] is set as LBa and LBaT is not '0'. lre T Press + keys for 3 sec. and it executes the set function. For more information, refer to Functions ' Digital input key'. When control type [C-MD] is OF, T is not displayed. etting range: 0.0 to 100.0% Only 0.0, 100% are displayed when control type [C-MD] is set as OF. When changing PID control to / control, if MV is below 100.0%, it is initialized as 0.0%. ensor witching upplies tepper Motors & s () oftware Parameter lock LOC LOC1 LOC2 LOC3 LOC1: Locks parameter group 2 LOC2: Locks parameter 1, 2 group LOC3: Locks parameter 1, 2 group and V setting Parameter setting values are still possible to check when parameter lock is set. -47

8 TCN eries Input ensor nd Range Input sensor range ( ) range ( ) K (C) KCa -50 to to 2192 KCaL to to J (IC) JIc -30 to to 1472 JIcL to to Thermocouple L (IC) LIc -40 to to 1472 LIcL to to T (CC) TCc -50 to to 752 TCcL to to RTD Factory Default V setting Parameter Mounting Factory default - 0 Parameter group 1 Parameter group 2 R (PR) R PR 0 to to 3092 (PR) PR 0 to to 3092 DPt100Ω DPt -100 to to 752 DPtL to to Cu50Ω CUs -50 to to 392 CUsL to to Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default L T I 0000 RET 05)0 L P 01)0 D 0000 Y 002 Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default IN-T KCa -V 1200 T 02)0 LBaB 0002 UNIT?C O-FT ET L-1 Mi DI-K TOP IN-B 0000 C-MD PID L-2 m@ ErMV 00)0 MvF 00)1 OUT RLY Y 001 LOC L-V -050 rm TND LBaT 0000 The C/DC voltage models do not have R drive output method [rm]. In case of control output [OUT], if set as R, it supports only / output. TCN4 (48 48mm) eries Other eries Mount the product on the panel, fasten bracket by pushing with tools as shown above. -48

9 Economical Dual Type, PID Control Functions larm [L-1 / L-2] larm operation larm operation M! larm option Mode Name larm operation Description M)_ - - No alarm output M! Deviation high-limit alarm V V igh deviation: et as 10 igh deviation: et as -10 et both alarm operation and alarm option by combining. larm outputs are two and each one operates individually. When the current temperature is out of alarm range, alarm clears automatically. If alarm option is alarm latch or alarm latch and standby sequence 1/2, press digital input key( + 3 sec., digital input key[di-k] of parameter group 2 set as lre), or turn the power and turn to clear alarm. If deviation between and V as high-limit is higher than set value of deviation temperature, the alarm output will be. () M@ Deviation low-limit alarm 90 V V 110 If deviation between and V as low-limit is higher than set value of deviation temperature, the alarm output will be. Lower deviation: et as 10 Lower deviation: et as -10 ockets M# M$ Deviation high/low-limit alarm Deviation high/low-limit reverse alarm V igh/lower deviation: et as 10 V igh/lower deviation: et as 10 If deviation between and V as high/low-limit is higher than set value of deviation temperature, the alarm output will be. If deviation between and V as high/low-limit is higher than set value of deviation temperature, the alarm output will be. () Rs / Power M% M^ Ba ensor break larm- It will be when it detects sensor disconnection. LBa Loop break larm - It will be when it detects loop break. : larm output hysteresis [Y] larm option Mode Name Description M. tandard alarm If it is an alarm condition, alarm output is. If it is a clear alarm condition, alarm output is. M.B larm latch If it is an alarm condition, alarm output is and maintains status. M.C First alarm condition is ignored and from second alarm condition, standard alarm operates. tandby sequence 1 When power is supplied and it is an alarm condition, this first alarm condition is ignored and from the second alarm condition, standard alarm operates. M.D larm latch and standby sequence 1 M.E tandby sequence 2 M.F bsolute value high limit alarm bsolute value low limit alarm larm latch and standby sequence 2 90 V bsolute-value larm: et as V bsolute-value larm: et as 90 V If it is an alarm condition, it operates both alarm latch and standby sequence. When power is supplied and it is an alarm condition, this first alarm condition is ignored and from the second alarm condition, alarm latch operates. First alarm condition is ignored and from second alarm condition, standard alarm operates. When re-applied standby sequence and if it is alarm condition, alarm output does not turn. fter clearing alarm condition, standard alarm operates. Basic operation is same as alarm latch and standby sequence 1. It operates not only by power /, but also alarm setting value, or alarm option changing. When re-applied standby sequence and if it is alarm condition, alarm output does not turn. fter clearing alarm condition, alarm latch operates. ensor break alarm The function that alarm output will be when sensor is not connected or when sensor's disconnection is detected during temperature controlling. You can check whether the sensor is connected with buzzer or other units using alarm output contact. It is selectable between standard alarm [Ba], or alarm latch [BaB]. 110 bsolute-value larm: et as 110 V 110 bsolute-value larm: et as 110 If is higher than the absolute value, the output will be. If is lower than the absolute value, the output will be. Condition of re-applied standby sequence for standby sequence 1, alarm latch and standby sequence 1: Power Condition of re-applied standby sequence for standby sequence 2, alarm latch and standby sequence 2: Power, changing set temperature, alarm temperature [L1, L2] or alarm operation [L-1, L-2], switching TOP mode to RUN mode. -49 peed / Pulse ensor witching upplies tepper Motors & s () oftware

10 TCN eries Loop break alarm () It checks control loop and outputs alarm by temperature change of the subject. For heating control (cooling control), when control output MV is 100% (0% for cooling control) and is not increased over than detection band [LBaB] during monitoring time [LBaT], or when control output MV is 0% (100% for cooling control) and is not decreased below than detection band [LBaB] during monitoring time [LBaT], alarm output turns. monitoring time monitoring time monitoring time monitoring time monitoring time V Control output MV 100% detection band invalid detection band invalid detection band detection band invalid 0% Loop break alarm () Time tart control to 1 1 to 2 2 to 3 3 to 4 4 to 6 6 to 7 7 to 8 8 to 9 When control output MV is 0% and is not decreased below than detection band [LBaB] during monitoring time [LBaT] The status of changing control output MV ( monitoring time is reset.) When control output MV is 0% and is not decreased below than detection band [LBaB] during monitoring time [LBa] loop break alarm () turns after monitoring time. Control output MV is 0% and loop break alarm () turns and maintains. The status of changing control output MV ( monitoring time is reset.) When control output MV is 100% and is not increased over than detection band [LBaT] during monitoring time [LBaT], loop break alarm () turns after monitoring time. When control output MV is 100% and is increased over than detection band [LBaB] during monitoring time [LBaT] loop break alarm () turns after monitoring time. The status of changing control output MV ( monitoring time is reset.) When executing auto-tuning, detection band [LBaB] and monitoring time are automatically set based on auto tuning value. When L1, L2 alarm operation [L-1, L-2] is set as loop break alarm () [LBa ], detection band [LBaB] and monitoring time [LBaT] parameter is displayed. R drive output function (RP function) [rm] RP function is selectable one of standard / control, cycle control, phase control by utilizing standard R drive output. Realizing high accuracy and cost effective temperature control as linear output(cycle control and phase control). elect one of standard / control [TND], cycle control [CYCL], phase control [P] at [rm] parameter of parameter group 2. For cycle control, connect zero cross turn-on R or random turn-on R. For phase control, connect random turn-on R. controller (TCN4 eries) R drive output (12VDC) R Module Load INPUT LOD Power VC 50/60z When selecting phase or cycle control mode, the power supply for load and temperature controller must be the same. In case of selecting PID control type and phase [P] / cycle [CYCL] control output modes, control cycle [T] is not allowed to set. For C/DC power model (TCN4-22R), this parameter is not displayed and it is available only standard control by relay or R. -50

11 Economical Dual Type, PID Control tandard / control mode [TND] mode to control the load in the same way as Relay output type. (: output level 100%, : output level 0%) Cycle control mode [CYCL] mode to control the load by repeating output / C according to the rate of output within setting cycle. aving improved / noise feature by Zero Cross type. OUT Phase control mode [P] mode to control the load by controlling the phase within C C half cycle. erial control is available. RNDOM Turn-on type R must be used for this mode. OUT uto tuning [T] ysteresis [Y] uto tuning measures the control subject's thermal characteristics and thermal response rate, and then determines the necessary PID time constant. (When control type [C-MD] is set as PID, it is displayed.) If error [OPEN] occurs during auto tuning, it stops this operation automatically. To stop auto tuning, change the set as. (It maintains P, I, D values of before auto tuning.) Input correction [IN-B] Controller itself does not have errors but there may be error by external input temperature sensor. E.g.) If actual temperature is 80 but controller displays 78, set input correction value [IN-B] as 002 and controller displays 80. s the result of input correction, if current temperature value () is over each temperature range of input sensor, it displays or LLLL. Input digital filter [MvF] If current temperature () is fluctuating repeatedly by rapid change of input signal, it reflects to MV and stable control is impossible. Therefore, digital filter function stabilizes current temperature value. For example, set input digital filter value as 0.4 sec, and it applies digital filter to input values during 0.4 sec and displays this values. Current temperature may be different by actual input value. V igh/low limit [-V/L-V] It sets V high/low limit Limit range of using temperature within temperature range for each sensor, user can set/ change set temperature (V) within V high limit [-V] to V low limit [L-V]. ( L-V>-V cannot be set.) When changing input type [IN-T], V high limit [- V] and V low limit [L-V] of using temperature will be initialized as max./min.value of sensor temperature range automatically. C OUT In case of / control, set between and intervals as hysteresis. (When control type [C-MD] is set as OF, it is displayed.) If hysteresis is too small, it may cause control output hunting (take off, chattering) by external noise, etc. Control output eating operation ysteresis [Y] V Manual reset [RET] When selecting P/PD control mode, certain temperature difference exists even after reaches stable status because heater's rising and falling time is inconsistent due to thermal characteristics of controlled objects, such as heat capacity, heater capacity. This temperature difference is called offset and manual reset [RET] function is to set/ correct offset. When and V are equal, reset value is 50.0%. fter control is stable, is lower than V, reset value is over 50.0% or is higher than V, reset value is below 50.0%. Manual reset [RET] by control result V 50Cycle 50Cycle 50% 80% 10% 50% Offset Offset et below 50.0 as reset value et over 50.0 as reset value unit selection [UNIT] function to select display temperature unit. Unit display indicator will be when converting temperature unit. Manual reset function is applicable only to P / PD control mode. () ockets () Rs / Power peed / Pulse ensor witching upplies tepper Motors & s () oftware -51

12 TCN eries Cool / eat function [O-FT] Generally there are two ways to control temperature, one (heat-function) is to heat when is getting down (heater). The other (cool-function) is to cool when is getting higher (freezer). These functions are operating oppositely when it is / control or proportional control. But in this case PID time constant will be different due to PID time constant will be decided according to control system when it is PID control. Cool-function [COOL] and heat-function [ET] must be set correctly according to the application, if set as opposite function, it may cause a fire. (If set cool-function [COOL] at heater, it will be maintained and it may cause a fire.) void changing heat-function to cool-function or coolfunction to heat-function when the unit is operating. It is impossible to operate both function at once in this unit. Therefore, only one function should be selected only. Control method selection [C-MD] It is selectable PID, / control. In case of / [OF] mode, ysteresis [Y] parameter is displayed. In case of PID [PID] mode, Proportional band [P], Integral time [I], and Derivative time [T] parameters are displayed. Control output type selection [OUT] It is selectable output type ; relay output [RLY], R drive output [R]. larm output hysteresis [Y] It displays alarm output and interval and hysteresis is applied to both L1 OUT and L2 OUT. KCa, JIc, LIc, TCc, RPR, PR, DPt, CUs : 1 to 100 KCaL, JIcL, LIcL, TCcL,DPtL, CUsL: 0.1 to 50.0 E.g.) L1 alarm operation [L-1]: M#, L1 alarm operation [L1]: 10, larm output hysteresis [Y]: 4 L1 OUT 210 V Control output MV when input sensor line is broken [ErMV] When input sensor line is broken or setting value error occurs, this function is to set control output. You can set / setting for / control, MV setting for PID control. : 4 : 4 Time Digital input key ( + 3sec.) [DI-K] Parameter Operation It does not use digital input key function. Pauses control output. uxiliary output (except loop break alarm, sensor break alarm)except Control output operates as setting. old the digital input keys for 3 sec. to restart. Digital input key RUN/TOP TOP t t t t (t: over 3 sec.) Clear alarm uto-tuning lre T RUN TOP RUN TOP RUN Clears alarm output by force. (only when alarm option is alarm latch, or alarm latch and standby sequence 1/2.) This function is applied when present value is out of alarm operation range but alarm output is. larm operates normally right after clearing alarm. tarts/tops auto-tuning. This function is same as auto-tuning[t] of parameter group 1. (You can start autotuning [T] of parameter group 1 and stop it by digital input key.) This parameter T appears only when control method [C-MD] parameter group 2 is set as PID. When control method [C-MD] parameter group 2 is set as OF, this parameter is changed as. Parameter lock [LOC] Error function to prevent changing V and parameters of each setting group. Parameter setting values are still possible to check when parameter lock is set. Description Lock off LOC1 Lock parameter group 2 LOC2 Lock parameter group 1, 2 LOC3 Lock parameter group 1, 2, V setting Description Flashes if input sensor is OPEN disconnected or sensor is not connected. Flashes if measured sensor input is higher than temperature range. LLLL Flashes if measured sensor input is lower than temperature range. Troubleshooting Check input sensor state. When input is within the rated temperature range, this display disappears. -52

13 Economical Dual Type, PID Control Output connections Refer to page -142 for output. pplication of relay output type TCN eries Relay contact terminal Condenser 0.1 μf 630V eater Magnet or Relay contact Power Keep length as long as possible when wiring the temperature controller and the load. If wire length of is short, counter electromotive force which occurs from a coil of magnet switch & power relay may flow in power line of the unit, and it may cause malfunction. If wire length of is short, please connect mylar condensers 104 (630V) on the both ends of " " (magnet coil) to protect electromotive force. pplication of R drive output method TCN eries Voltage output terminal + - I N P U T R Power Load power R should be selected by the capacity of load, otherwise, it may short-circuit and result in a fire. Indirect heated should be used with R for efficient working. Please use a cooling plate or it may cause the capability deterioration, breakdown of R for a long usage. Refer to page -50 for phase/cycle control connections. L O D () ockets () Proper Usage Rs / Power imple "error" diagnosis When the load (eater etc) is not operated Please check operation of the OUT indicator located in front panel of the unit. If the OUT indicator does not operate, please check the parameter of all programmed mode. If indicator is operating, please check the output (Relay, R drive voltage) after separating output line from the unit. When it displays OPEN during operation This is a warning that external sensor is open. Please turn off the power and check the wire state of the sensor. If sensor is not open disconnect sensor line from the unit and short the input +, - terminal. Turn on the power of the unit and check the controller displays room temperature. If this unit cannot display room temperature, this unit is broken. Please remove this unit and contact our service center. (When the input mode is thermocouple, it is available to display room temperature.) Caution during use The connection wire of this unit should be separated from the power line and high voltage line in order to prevent from inductive noise. For crimp terminal, select following shaped terminal (M3) Max. 5.8mm Max. 5.8mm Please install power switch or circuit-breaker in order to cut power supply off. The switch or circuit-breaker should be installed near by users. This unit is designed for temperature controlling only. Do not apply this unit as a voltage meter or a current meter. In case of using RTD sensor, 3-wire type must be used. If you need to extend the line, 3-wire must be used with the same thickness as the line. It might cause temperature difference if the resistance of line is different. In case of making power line and input signal line close, line filter for noise protection should be installed at power line and input signal line should be shielded. Keep away from the high frequency instruments. (igh frequency welding machine & sewing machine, big capacitive CR controller) When supplying measured input, if or LLLL is displayed, measured input may have problem. Turn off the power and check the line. This unit may be used in the following environments. Indoor ltitude: Under 2,000m Pollution degree 2 Installation category Ⅱ peed / Pulse ensor witching upplies tepper Motors & s () oftware -53

Control output N Indicator - Without control output R Relay output + SSR drive output (4-digit) Set by touch switch

Control output N Indicator - Without control output R Relay output + SSR drive output (4-digit) Set by touch switch TC eries ingle, PID Control Controller Features Realizes ideal temp. controlling with newly developed PID control algorithm and 1ms high speed sampling Built-in relay output or R output selectable : Enables

More information

R Relay output S SSR drive output C Selectable current output or SSR drive output VAC 50/60Hz

R Relay output S SSR drive output C Selectable current output or SSR drive output VAC 50/60Hz Controller Features Super high-speed sampling with 50ms Improved visibility with LCD display Communication function supported: RS485 (Modbus RTU) Convenient parameter setting (RS485 communication) : Free

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00kHz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters, CN-6000 eries Features Multi-input CN-610 : Thermocouple 12 types, RTD 5 types, Analog (mv, V, ma) 6 types CN-640 : 0 to 50.00 khz Improves visibility with negative LCD : 12 segment, 3 colors (selectable

More information

TK Series. High Function/High Performance PID Control.

TK Series. High Function/High Performance PID Control. TK eries igh Function/igh Performance PID Control Features Convenient parameter setting (by DAQMaster) - Parameter mask ides unnecessary and seldom used parameters - User parameter group Groups usually

More information

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA TC3YF Freezing/ type DIN W72 H36mm Freezing/ type Features ON/ Control Input specification - Basic specification: NTC(Thermistor), Option: RTD(DPt100Ω) Temperature display range NTC type: -40.0 to 99.9

More information

KPN Series. Features. Manual. Integrated device management program(daqmaster)

KPN Series. Features. Manual. Integrated device management program(daqmaster) KPN eries Features uper high-speed sampling cycle (10 times faster compared to existing models) : 50 ms sampling cycle and ±0.3% display accuracy Improved visibility with wide display and high luminance

More information

KPN Series. Features. Manual. Integrated device management program(daqmaster)

KPN Series. Features. Manual. Integrated device management program(daqmaster) KPN eries Features uper high-speed sampling cycle (10 times faster compared to existing models) : 50 ms sampling cycle and ±0.3% display accuracy Improved visibility with wide display and high luminance

More information

KPN Series. Features. Manual. Software

KPN Series. Features. Manual. Software KPN eries Features uper high-speed sampling cycle (10 times faster compared to existing models) : 50 ms sampling cycle and ±0.3% display accuracy Improved visibility with wide display and high luminance

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep

More information

Preface USER MANUAL. Copyright Reserved Autonics Co., Ltd. I

Preface USER MANUAL. Copyright Reserved Autonics Co., Ltd. I Preface USER MANUAL Copyright Reserved Autonics Co., Ltd. I Preface II Copyright Reserved Autonics Co., Ltd. Preface Preface Thank you for purchasing an Autonics product. Please familiarize yourself with

More information

Instruction manual Temperature Controller KT7

Instruction manual Temperature Controller KT7 Instruction manual Temperature Controller KT7 No. KT71E7 201.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma) TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and

More information

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates

More information

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates

More information

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100 INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Controller 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to ±0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable

More information

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A Preface Thank you for the purchase of our Microcomputer based Temperature Indicating Controllers JCD-13A or

More information

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER 1 DCL-A DC No.DCLDCE1 2007.01 Thank you for purchasing our DIN rail mounting type indicating controller DCL-A DC. This manual contains instructions

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...

More information

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as

More information

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03 Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications

More information

Thank you for purchasing an Autonics product.

Thank you for purchasing an Autonics product. User Manual Preface Preface Thank you for purchasing an Autonics product. Please familiarize yourself with the information contained in the Safety Precautions section before using this product. This user

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200 PV PV AT AT OUT1 OUT2/HB A1 A2 OUT1 OUT2/HB A1 A2 MODE OUT MODE OUT GCD GCR Preface Thank you for the purchase

More information

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Instruction manual for DIN rail mounting type indicating controller DCL-33A Instruction manual for DIN rail mounting type indicating controller DCL-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

F4 Process Controller Installation and Operation Guide

F4 Process Controller Installation and Operation Guide F4 Process Controller Installation and Operation Guide 1.Introduction 1.1.Highlight Features Space saving, only 55mm panel depth required Higher sampling rate (1mS) results in better control performance

More information

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning

More information

TEMPERATURE CONTROL MODULE MODEL R3-TC2

TEMPERATURE CONTROL MODULE MODEL R3-TC2 INSTRUCTION MANUAL R3-TC2 TEMPERATURE CONTROL MODULE MODEL R3-TC2 CONTENTS BEFORE USE... 2 POINTS OF CAUTION... 2 COMPONENT IDENTIFICATION... 2 INSTALLATION... 2 EXTERNAL DIMENSIONS unit: mm (inch)...

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL Preface Thank you for purchasing our Digital indicating controller FCS-23A. This manual contains instructions for the mounting, functions, operations

More information

GCS-300 No.GCS31E

GCS-300 No.GCS31E INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller GCS-00 No.GCS1E 200.0 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

DIGITAL INDICATOR DI25

DIGITAL INDICATOR DI25 DIGITAL INDICATOR DI25 Operating instructions Preface Thank you for purchasing our digital indicator DI25. This manual contains instructions for the mounting, functions, operations and notes when operating

More information

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02 Temperature Controller Fuzzy Self-tuning Temperature Controller with Advanced PID (2-PID) Control DIN-size: 6 x 6 mm (E5AJ), 2 x 2 mm (E5BJ), 4 x 4 mm (E5CJ), 4 x 6 mm (E5EJ) Fuzzy self-tuning and Auto-tuning

More information

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0) Serie 5000 Tel. +1 (0)5 222 Fax +1 (0)5 222 12 PRODUCT INTRODUCTI PRODUCT INTRODUCTI 5 Series programmable temperature controller is FineTek's mid-range series of controllers. It uses a 12bit analog /

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

INSTRUCTION MANUAL Micro-computer based digital indicating controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller INSTRUCTI MANUAL Micro-computer based digital indicating controller TP4A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual. Caution

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None Series Features 50mm thermal transfer method of paper recorder Data logger function for recording without paper Supports RS485 communication and dedicated communication port to set or monitor parameters

More information

Instruction manual Micro-computer based digital indicating controller

Instruction manual Micro-computer based digital indicating controller Instruction manual Micro-computer based digital indicating controller JCS-33A To prevent accidents arising from the misuse of this controller, please ensure the operator using it receives this manual.

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 48VTR Product Info Page Instruction Manual English / Español

More information

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. INSTRUCTI MANUAL DIN RAIL MOUNTING TYPE INDICATING CTROLLER DCL-A No.DCL1E5 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information

Power Controller THV-A1 Series

Power Controller THV-A1 Series Power Controller THV- Series (2,3,,,8, type) THV- General Description s the THV- single phase power control unit can be used with control modes selectable from constant, constant and constant power, it

More information

MICRO CONTROLLER S Z SERIES

MICRO CONTROLLER S Z SERIES Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure

More information

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation

More information

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR JIR-301-M DIGITAL INDICATOR JIR-301-M Instruction Manual Preface Thank you for purchasing our digital indicator JIR-301-M. This manual contains instructions for the mounting, functions, operations and notes when

More information

Nov 08 PRODUCT SPECIFICATION SHEET

Nov 08 PRODUCT SPECIFICATION SHEET Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock. Temperature Controller KXN Series INSTRUCTION MANUAL Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using

More information

VERTEX F4 Instruction Manual

VERTEX F4 Instruction Manual VERTEX F4 Instruction Manual 02/2018 The VERTEX F4 controller 1/16 DIN is our LOW COST yet HIGH SPEC controller. Configurable on input between various thermocouples from the keypad by the user or when

More information

4TEMPERATURE CONTROLLER

4TEMPERATURE CONTROLLER Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and

More information

Buzzer Unit. TAN-5000 Series. Operating Manual

Buzzer Unit. TAN-5000 Series. Operating Manual PT1E-1040 Buzzer Unit TAN-5000 Series Operating Manual Request for the Customers Read and understand this operating manual before using the buzzer unit. Use the buzzer unit in accordance with the operating

More information

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT PREFACE Thank you for your purchase of our Touch panel monitoring unit. This manual contains instructions for the mounting, functions, operations and

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and

More information

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL DIN RAIL MOUNTED INDICATING CONTOLLER DCL-A INSTRUCTION MANUAL Preface Thank you for purchasing our DIN rail mounted indicating controller DCL-A. This manual contains instructions for the mounting, functions,

More information

TC515 and TC600 Installation Manual. a Winters company

TC515 and TC600 Installation Manual. a Winters company THERMOLINE TEMPERATURE CONTROLLERS TC515 and TC600 Installation Manual a Winters company Guarantee 12 months Congratulations on the purchase of this new product. Special care with the design, workmanship

More information

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Table of Contents SECTION PAGE

Table of Contents SECTION PAGE Table of Contents SECTION PAGE SECTION 1 INTRODUCTION................... 1.1 Description.............................. 1.2 Features................................ 1.3 Models.................................

More information

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min

More information

Model 96VTR ¼ DIN Process Controller

Model 96VTR ¼ DIN Process Controller 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 96VTR Product Info Page INSTRUCTION MANUAL Model 96VTR ¼ DIN

More information

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Process & TeMPerATUre UniversAl input DigiTAl MeTers Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min

More information

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1 Jun. 2007 Auber Instruments, 730 Culworth, Alpharetta, GA 30022 www.auberins.com e-mail: auberins@gmail.com Tel: 404-291-6298 WARNING

More information

CN4800 Series CONTROLLER

CN4800 Series CONTROLLER CN4800 Series CONTROLLER Operator's Manual PV SV OUT1 OUT2 ALM1 ALM2 SEL M1791/0502 Contents I. PREPARING THE OPERATION... 4 1. THE BASIC INSTALLATION PROCEDURE... 5 2. CHECK OF SPECIFICATIONS... 6 2.1

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment

More information

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:

More information

Refrigeration Temperature Controller

Refrigeration Temperature Controller TF3 eries Refrigeration Controller Features tandard installation size for refrigeration and air-cooling panels (W7.3 H28.2mm) Various compressor load current capacity: 5A, 16A, 2A Various user-friendly

More information

Oakton TEMP 9000 Advanced Thermocouple Controller

Oakton TEMP 9000 Advanced Thermocouple Controller Oakton TEMP 9000 Advanced Thermocouple Controller Models: 89800-01 & 89800-02 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents Safety...

More information

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4

More information

Refrigeration Temperature Controller

Refrigeration Temperature Controller TF3 eries Refrigeration Controller Features tandard installation size for refrigeration and air-cooling panels (W7.3 H28.2mm) Various compressor load current capacity: 5A, 16A, 2A Various user-friendly

More information

CG Series Digital Temperature Controller OPERATIONS MANUAL

CG Series Digital Temperature Controller OPERATIONS MANUAL CG-15001 Series Digital Temperature Controller OPERATIONS MANUAL C 3800 North Mill Road Vineland, NJ 08360 USA Tel: 1-800-843-1794 Fax: 1-800-922-4361 Index Page Quick Set-Up..3 Tuning..4 Auto-Tuning...4

More information

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL Thermocouple Type BS4937 (IEC584-3): Outer / + / - BS1843 (Old UK Standard) Outer / + / - US Outer / + / - J : Iron / Copper-Nickel Black / Black / White Black / Yellow / Blue Black / White / Red VT4810

More information

Temperature Controller

Temperature Controller E5AN Temperature Controller Temperature Controller OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku,

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E3 24.7 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11 Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.

More information

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTI MANUAL MICRO-COMPUTER BASED DIGITAL INDICATOR JIR-31-M No.JIR31E6 28.8 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. SAFETY

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support. AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution

More information

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

Example of Applications and Parameter Functions

Example of Applications and Parameter Functions PX-series digital temperature controller Example of Applications and Functions ECNO:1158 I. Example of Applications 1 Controlling both heating and cooling with a single controller Only one controller is

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual. INP-TN1PXR5/9f-E

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual. INP-TN1PXR5/9f-E Instruction Manual Micro-controller X Model : PXR5/9 INP-TNPXR5/9f-E International Sales Div Sales Group Gate City Ohsaki, East Tower, -, Osaki -chome, Shinagawa-ku, Tokyo 4-, Japan http://www.fujielectric.com

More information

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad. INSTRUCTI MANUAL (EXCERPT) Digital Indicating Controller ACS-13A- /A (For Use with the Infrared Temperature Sensor RD-500) No.ACS11AE1 2011.07 The digital indicating controller ACS-13A /A is an exclusive

More information

Temperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC.

Temperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC. Temperature Controller SA100 Initial Setting Manual RKC INSTRUMENT INC. IMR01J03-E1 Modbus is a registered trademark of Schneider Electric. Company names and product names used in this manual are the trademarks

More information

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately) Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

CLEANROOM MONITOR CR3A Network - Installation Instructions

CLEANROOM MONITOR CR3A Network - Installation Instructions CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.

More information

Series 945 User s Manual

Series 945 User s Manual Series 945 User s Manual TOTAL CUSTOMER SATISFACTION 3 Year Warranty 1/4 DIN Microprocessor-Based Auto-tuning Control Watlow Controls 1241 Bundy Blvd., P.O. Box 5580, Winona, Minnesota USA 55987-5580,

More information

DIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL

DIGITAL INDICATING CONTROLLER. BCx2 INSTRUCTION MANUAL DIGITAL INDICATING CONTROLLER BCx2 INSTRUCTION MANUAL Preface Thank you for purchasing our digital indicating controller BCx2 (BCS2, BCR2, BCD2). This manual contains instructions for the mounting, functions,

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information