ENA Engineering Recommendation G83 Issue

Size: px
Start display at page:

Download "ENA Engineering Recommendation G83 Issue"

Transcription

1 ENA Engineering Recommendation G83 Issue Type Verification Test Report Type Approval and manufacturer/supplier declaration of compliance with the requirements of Engineering Recommendation G83/2. SSEG Type reference number SSEG Type System Supplier name Address GW1000 NS/GW1500 NS/GW2000 NS/GW2500 NS/GW3000 NS Jiangsu GoodWe ower Supply Technology Co.,Ltd. NO.189 Kun Lun Shan Road, Suzhou New District, Jiangsu,china Tel Fax E:mail service@goodwe.com.cn Web site Connection Option Maximum rated capacity( use separate sheet if more than one connection option) 1 kw single phase 1.5 kw single phase 2 kw single phase 2.5 kw single phase 3 kw single phase SSEG manufacturer/supplier declaration. I certify on behalf of the company named above as a manufacturer/supplier of Small Scale Embedded Generators, that all products manufactured/supplied by the company with the above SSEG Type reference number will be manufactured and tested to ensure that they perform as stated in this Type Verification Test Report, prior to shipment to site and that no site modifications are required to ensure that the product meets all the requirements of G83/2. Signed Xie Jing On behalf of Huang min

2 ower Quality. Harmonics The requirement is specified in section 5.4.1, test procedure in Annex A or B Harmonic SSEG rating per phase (rpp) At 45 55% of rated ouput Measured Value (MV) in kw Normalised Value (NV) in 100% of rated output Measured Value (MV) in kw Normalised Value (NV) in NV=MV*3.68/rpp Limit in BS EN in 2nd rd th th th th th th th th th th th th th th th th th Higher limit for odd harmonics 21 and above 21th th th th th th th th th th th th th th

3 35th th th th th th Note: The higher limits for odd harmonics 21 and above are only allowable under certain conditions, if these higher limits are utilised please state the exemption used as detailed in part of BS EN in the box below. Flicker The requirement is specified in section 5.4.2, test procedure in Annex A or B Starting Stopping Running d max d c d (t) d max d c d (t) st lt 2 hours Measured values Normalised to standard impedance and 3.68kW for multiple units Limits set under BS EN 4% 3.3% % 3.3% 4% 3.3% 1.0 0,65 500ms 500ms Test start date :50 Test end date :50 ower quality. DC injection The requirement is specified in section 5.5, test procedure in Annex A or B Test level power 10% 55% 100% Recorded value 6.2mA 2.9mA 8.3 ma As % of rated AC current 0.062% 0.029% 0.07% Limit 0.25% 0.25% 0.25% Diagramm of permanent DC Injec (ma) DCI 0.25%Irated 0.25%Irated

4 ower Quality. ower factor The requirement is specified in section 5.6, test procedure in Annex A or B V 230V 253V Measured at three voltage levels and at full Measured output. Voltage to be maintained within value ±1.5% of the stated level during the test. Limit >0.95 >0.95 >0.95 rotection. Frequency test The requirement is specified in section 5.3.1, test procedure in Annex A or B Function Setting Trip test No test Frequency Time delay Frequency Time delay U/F stage Hz 20s Hz 20.2s U/F stage 2 47Hz 0.5s 46.95Hz 0.814s O/F stage Hz 90s 51.55Hz 93.4s O/F stage 2 52Hz 0.5s 52.05Hz 0.886s Frequency / time 47.7Hz / 25s 47.2Hz / 19.98s 46.8Hz / 51.3Hz / 95s 51.8Hz / 89.98s 52.2Hz / Confirm no rotection. Voltage test The requirement is specified in section 5.3.1, test procedure in Annex A or B Function Setting Trip test No test Voltage Time delay Voltage Time delay U/V stage V 2.5s U/V stage 2 184V 0.5s O/V stage V 1.0s s O/V stage V 0.5s Voltage / time 204.1V / 3.5s 188V / 2.48s 180V / 258.2V 2.0s 269.7V 0.98s 277.7V Confirm no

5 rotection. Loss of Mains test inverters can be tested to BS EN Test ower and 33% 66% 100% 33% 66% 100% imbalance 5% Q 5% Q 5% +5% Q +5% Q +5% Trip time. Limit is 0.5s s s s s s s rotection. Frequency change, Stability test The requirement is specified in section 5.3.3, test procedure in Annex A or B Start Change End Frequency Frequency Confirm no ositive Vector Shift 49.5Hz +9 degrees Negative Vector Shift 50.5Hz 9 degrees ositive Frequency drift 49.5Hz +0.19Hz/sec 51.5Hz Negative Frequency drift 50.5Hz 0.19Hz/sec 47.5Hz rotection. Re connection time The requirement is specified in section Automatic Reconnection, test procedure in Annex A or B Test should prove that the reconnection sequence starts after a minimum delay of 20 seconds for restoration of voltage and frequency to within the stage 1 settings of table 1. Voltage Time delay setting Measured delay time(s) 20s 47.05s Frequency Time delay setting Measured delay time(s) 20s 47.15s Confirmation that the SSEG does not re connect. Checks on no reconnection when voltage or frequency is brought to just outside stage 1 limits of table 1. At 266.2V At 196.1V At 47.4Hz At 51.6Hz no reconnection no reconnection no reconnection no reconnection

6 Short circuit Current Contribution The requirement is specified in section 5.7, test procedure in Annex A or B For a directly coupled SSEG arameter Symbol Value Time after fault For a Inverter SSEG Volts eak Short Circuit current 20ms 10.2V 270mA Initial Value of aperiodic current Initial symmetrical short circuit current* Decaying (aperiodic) component of short circuit current* Reactance/Resistance Ratio of source* 100ms 10.5V 310mA 250ms 10.1V 510mA 500ms 11.2V 380mA Time to 680µs In seconds Self Monitoring Solid state Disconnection The requirement is specified in section 5.3.1, No specified test requirements. Not applicable since electro mechanical relays are used. N/A Additional comments GW1000 NS,GW1500 NS,GW2000 NS,GW2500 NS is similar to GW3000 NS in circuit and construction except for output rating of current and power. The test result can refer to GW3000 NS.

PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION

PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Engineering Recommendation G83 Issue 2 Amendment 1 July 2018 Recommendations for the Connection of Type Tested Small-scale Embedded

More information

Documentation guide to get your plant on the positive list (Category A1/A2)

Documentation guide to get your plant on the positive list (Category A1/A2) Documentation guide Document officer : MER Secretary: SLS Caseno..: s2016-457 Document no.: d2016-14033-8.0 27-01-2017 Documentation guide to get your plant on the positive list (Category A1/A2) In the

More information

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks TEST REORT SUMMARY EN 50438 Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks Report reference number... : 12TH0525-EN50438_SUM_0 Date of issue......:

More information

This EREC G98 draft uses text from a number of sources and is therefore colour coded to demonstrate where the words have come from as follows.

This EREC G98 draft uses text from a number of sources and is therefore colour coded to demonstrate where the words have come from as follows. To incorporate the EU Network Code Requirement for Generators (RfG) with existing GB documentation a number of new Engineering Recommendations are being drafted. G98 covers the connection procedure and

More information

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)... TEST REORT AS 4777.2:2005 and AS 4777.3:2005 with additional deviations for Israel Grid connection of energy systems via inverters Grid protection requirements Report reference No...: 10TH0052_AS4777_+_ISR_3

More information

Consumer Products Services Germany GmbH Türkheim Germany

Consumer Products Services Germany GmbH Türkheim Germany TEST REORT SUMMARY EN 50438 Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks Report reference number... : 11TH0290-EN50438_SUM_2 Date of issue......:

More information

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy Reyrolle Protection Devices 7PG26 DAD High Impedance Current Relay Answers for energy Siemens Protection Devices Limited 2 7PG26 DAD High Impedance Circulating Current Relay Description The type DAD relay

More information

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Microgrid Fault Protection Based on Symmetrical and Differential Current Components Microgrid Fault Protection Based on Symmetrical and Differential Current Components Prepared for Public Interest Energy Research California Energy Commission Prepared by Hassan Nikkhajoei and Robert H.

More information

NEW CONNECTION Heat Pump Application Form C

NEW CONNECTION Heat Pump Application Form C NEW CONNECTION Heat Pump Application Form C greater than 75A per phase Please submit your completed application form to: Northern Powergrid, Network Connections, Alix House, Falcon Court, Stockton-on-Tees,

More information

Description (Data Point Name) Unit Size

Description (Data Point Name) Unit Size AC-PRO-II Communications Modbus Register Map Document Revision 2.0 Firmware v2.0 AC-PRO-II: Registers 7000 7019: Output Coils 7020 7099: Information 7107 7199: User settings (can be set using Modbus Communications)

More information

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option Description of options Option A4, Loss of mains protection package Automatic Gen-set Controller 4189340373C SW version 2.3X.X Description of option Functional description DEIF A/S Parameter list Response

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

PAC1500Xi PORTABLE APPLIANCE CHECKER

PAC1500Xi PORTABLE APPLIANCE CHECKER PAC1500Xi PORTABLE APPLIANCE CHECKER OPERATING INSTRUCTIONS 211A912 CONTENTS 1) Safety... 1 2) Introduction & Description... 2 3) Applications... 2 4) Test Sequence... 3 5) Visual Inspection... 3 6) Earth

More information

CIRCUIT BREAKER FAIL PROTECTION

CIRCUIT BREAKER FAIL PROTECTION CIRCUIT BREAKER FAIL PROTECTION This document is for Relevant Electrical Standards document only. Disclaimer NGG and NGET or their agents, servants or contractors do not accept any liability for any losses

More information

SENTINEL A - Fault Passage Indicator

SENTINEL A - Fault Passage Indicator SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

RQE Series Temperature Controllers

RQE Series Temperature Controllers RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc flash detection units. Product picture Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Protection Chain IQ-Sensor + Relaiy device T420

Protection Chain IQ-Sensor + Relaiy device T420 APPLICATION NOTES Protection Chain IQ-Sensor + T420 Protection Chain IQ-Sensor + Relaiy device T420 According to IEC 61508 SAFETY Integrity Level 2 I N C H A R G E O F S P E E D 2/7 1 Introduction This

More information

Table of Contents. Protective Relays

Table of Contents. Protective Relays Table of Contents KILOVAC WD Series, DIN Rail or Screw Mounted Introduction..........................................................11-2 KILOVAC WD25 Paralleling Relays........................................11-3

More information

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1)

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1) MGD Murco Gas Detector Check / Calibration Procedure* Content Page 1- Introduction 2 2- Electrical Set-Up 2 3- Bump Test 2 4- Calibration 3 4.1 Exchange Sensor board 3 4.2 Gas Calibration 3 5- Additional

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

SENTINEL D - Fault Passage Monitoring

SENTINEL D - Fault Passage Monitoring SENTINEL D - Fault Passage Monitoring DIRECTIONAL FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-D range allows locating the fault arisen

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting

More information

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities. Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities. 7PG17 XR105, XR106 and XR107, XR205 and XR206 Interposing

More information

See product BS EN :2010

See product BS EN :2010 DECLARATION OF PERFORMANCE TLX UV 10 BMTLXUV10CPR 1. Unique identification code of the product-type: TLX UV10 Breather Membrane 2. Type, batch or serial number or any other element allowing identification

More information

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 highline WINDOW CONTROLS INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM SVCS-1 * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10 CERTIFICATE OF COMPLIANCE SVCS-1 We the undersigned

More information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module FIRE ALARM CONTROL EQUIPMENT Addendum October 2006 Instructions for new style EN54-4 Power supply unit module MXLK-05 Issue 2.0 June 2007 INSTALLATION Safety Suppliers of articles for use at work are required

More information

HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.

HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair. HD COMMUNICATOR Next Generation Communications for Railway Networks Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair. Echelon & Ethernet connectivity.

More information

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR Installation Manual DDS-S SENSOR 1 TRANSLATED DOCUMENT This manual has been compiled according to standard UNE-EN-ISO 12100. INSTALLATION MANUAL DDS-S SENSOR Read thoroughly all of these instructions before

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Langer Road Contact: Mr I Frost Felixstowe Tel: +44 (0)1394 694000 Suffolk Fax: +44 (0)1394 276030 IP11 2ER E-Mail: ian.frost@itron.com Website:

More information

Inverter control panels........................ 152 Inverter control panels with safety............... 153 Level control panel........................... 155 Temperature control panel.....................

More information

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIREBETA EXTINGUISHING CONTROL PANEL (ECP) F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

B SERIES ELECTRIC FURNACE

B SERIES ELECTRIC FURNACE MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure

More information

Operating Instructions. For. Alarm Control Module. Model SSR 500

Operating Instructions. For. Alarm Control Module. Model SSR 500 SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions

More information

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D DETECTION SYSTEMS GCM Auto Alarm Instruction Manual GA0203P01 Rev. D Contents Limited Warranty... 3 Warning... 4 Safety Consideration... 4 General Description... 5 Installation... 6 Initial Adjustments...

More information

SPACEMOTION SERIES SMM 01

SPACEMOTION SERIES SMM 01 SPACEMOTION SERIES SMM 01 Description K-Band motion and direction detection Max sensing range: 3 metres Adjustable sensing field range Adjustable slow speed zone Selectable background suppression Selectable

More information

Eclipse Trilogy Flame Safeguard Modulating Sequences

Eclipse Trilogy Flame Safeguard Modulating Sequences Instruction Manual 830-2 2/25/2011 Eclipse Trilogy Flame Safeguard Modulating Sequences Series T420 Version 1 Copyright Copyright 2009 by Eclipse, Inc. All rights reserved worldwide. This publication is

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...: Test Report issued under the responsibility of: TEST REORT IEC 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) art 1: General

More information

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Universal controller for panel mounting Models CS6S, CS6H, CS6L Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing

More information

FCR 05, FCR 07. Power factor correction controller. User and service manual

FCR 05, FCR 07. Power factor correction controller. User and service manual FCR 05, FCR 07 Power factor correction controller User and service manual version 2.3 Czech Republic Czech Republic 1 Content 1. Control and signal elements... 3 2. Device description... 4 3. Instruction

More information

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225. Gasflag Single Channel Control Panel Alarm Only Apparatus Installation, operating and maintenance instructions, M07225 Issue 2 1/07/05 Crowcon Detection Instruments Ltd 2 Blacklands Way Abingdon Business

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR200-24S / OPR200-24R Manual Revision F May 2010 Optimal Power Supplies LLC www.optimal-power.com i PROPRIETARY

More information

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS SERIES 35-65 24 VAC Microprocessor-Based Hot Surface Ignition Control F-35-65 August 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings* 120/240

More information

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Technical Information RTA421 Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Application Plant and machine construction Panel builders Process monitoring Process

More information

Segment design & and Bus Diagnostics

Segment design & and Bus Diagnostics Segment design & and Bus Diagnostics Arasu Thanigai Business Development Manager Pepperl+Fuchs Pte Ltd, Singapore On behalf of FF End user Council Taiwan 1 Taiwan FF Seminar Part1 - Segment design & Verification

More information

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

Item Number Description Price. Accessories  Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22 DIGITAL Vessel Monitoring 1800 Monitor Monitor includes head unit, surface mount bezel, surface mount gasket, DC current shunt 8255, AC current transformer 8256, battery temperature sensor 1820, connectors,

More information

The test items passed the test specification(s).

The test items passed the test specification(s). Report NO.: NTRE20170442 Test Report No.: NTRE20170442 age 1 of 17 Applicant Name: Test item: Gree Electric Appliances Inc. of Zhuhai West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Split Air

More information

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504 Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages) Measuring relays RM2I 2 module housing (single-phase alternating current) RM2U 2 module housing (single-phase alternating current) RM3I Rail DIN housing (three-phase alternating current) RM3U Rail DIN

More information

APPENDIX C APPROVAL PROCESS SUBMISSION FORMS. HCJ/LJ/B100841/JR Issue I April 16. Appendix C

APPENDIX C APPROVAL PROCESS SUBMISSION FORMS. HCJ/LJ/B100841/JR Issue I April 16. Appendix C APPENDIX C APPROVAL PROCESS SUBMISSION FORMS STEP 2A CONCEPT DESIGN SUBMISSION To: Edward Utteridge From: Jonathan Everitt jeveritt@oriumdesign.co.uk Terry Lailey t.lailey@oriumdesign.co.uk Checklist (tick

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100 Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100 Four Channels of Process Variable Bargraph Indication Four Channels of Integration and Digital Totalization An Alarm/Annunciator Summary Intuitive

More information

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide Instruction Manual EESIFLO EASZ-12 Doppler Flow Switch 55 120 0-2 m/s Lo Alarm 0-6 m/s Hi Alarm 120 Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide Doppler Flow Switch - EASZ-12 Introduction

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508 Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional

More information

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

EARTH LEAKAGE RELAY. User Manual - Issue 1.0 Earth Leakage Relay www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters EARTH

More information

DS1286 Watchdog Timekeeper

DS1286 Watchdog Timekeeper www.dalsemi.com FEATURES Keeps track of hundredths of seconds, seconds, minutes, hours, days, date of the month, months, and years; valid leap year compensation up to 2100 Watchdog timer restarts an out-of-control

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

1022 R/T Remote Monitor

1022 R/T Remote Monitor 1022 R/T Remote Monitor INSTRUCTIONS AMC-1022R/T WITH REMOTE SENSOR OR TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS FOR THE AMC-1022R/T UNIT IMPORTANT: Please read these installation and operating

More information

hgate Product Catalog

hgate Product Catalog hgate Product Catalog Hydraulic activegate Control Stabilize your Process CAT-16-0023_EN-Rev03 EN 06/2017 Hydraulic Control System Product Description hgate Hot Runner System Proportionally controlled

More information

Series 65 Product Guide MAN 3036

Series 65 Product Guide MAN 3036 Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety

More information

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk

More information

Forced draught gas burner

Forced draught gas burner Installation, use and maintenance instructions GB Forced draught gas burner One stage operation CODE MODEL TYPE 3751782 GAS 5 517T80 291 (4) - 07/2015 Declaration of conformity in accordance with ISO /

More information

Operating Manual VMD420

Operating Manual VMD420 Operating Manual VMD420 Voltage and frequency monitor for monitoring of 3(N)AC systems up to 0...500 V for undervoltage and overvoltage and under and overfrequency Software version: D238 V2.2x Power in

More information

- Check Test Methodology for Tumble Dryers Energy Label & Ecodesign -

- Check Test Methodology for Tumble Dryers Energy Label & Ecodesign - - Check Test Methodology for Tumble Dryers Energy Label & Ecodesign - Guidelines and procedures on how to perform simplified check testing operations for tumble dryers Version 6.0 April 2015 Table of

More information

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,

More information

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.

More information

Safety Speed Monitoring

Safety Speed Monitoring Monitoring Considerations about sensors in applications for safety speed monitoring Marketing Documentation - November 2013 MV - Rev. 1.0 MOSAIC MV and SENSORS Encoder Proximity MV Module Safety Level

More information

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3 DUCT AIR HEATER WITH BUILT-IN CONTROLS Installation & User Instructions Stock Ref. 105 31 100 T1 105 31 125 T1 105 31 150 T1 105 31 200 T1 105 31 250 T1 105 31 315 T1 Stock Ref. 105 31 315 T3 105 31 400

More information

APM110 LOW AIR VELOCITY ALARM

APM110 LOW AIR VELOCITY ALARM home APM0 LOW AIR VELOCITY ALARM Ultra low velocity measurement Output as linear Velocity or Air volume Excellent repeatability Excellent Zero Stability Climate chamber compensated Long term span stability

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4 Contactor Panel with GFEP Data Sheet GENERAL PRODUCT INFORMATION Simplify your snowmelt installation with ProLine Radiant contactor panels with built in GFEP. These rugged panels feature built-in ground

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White Digital Panel Meters 47 Series CT DIGITA PANE METER (4½ digit, ED display type, true RMS sensing) Functions & Features 4 ½ digit CT input digital panel meter 1/8 DIN size Moving average function to suppress

More information

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd. Test Report issued under the responsibility of: TEST REORT IEC 60825-1 Safety of laser products - art 1: Equipment classification and requirements Report Number.... : 50089797 001 Date of issue... : 2017.07.25

More information

DANFOSS OPTYMA PLUS INVERTER UNITS

DANFOSS OPTYMA PLUS INVERTER UNITS Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a

More information

Amendment Number 3 of BS how it might affect you

Amendment Number 3 of BS how it might affect you Amendment Number 3 of BS7671 2008 - how it might affect you Geoff Cronshaw provides us with a look ahead at the proposals of Amendment 3 to BS 7671:2008 IET Wiring Regulations and the resulting changes

More information

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009 Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Man-1048 Issue 05 October 2009 CONTENTS Contents... Page Safety & Installation...2 Installation - continued...3

More information

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

nugate Product Catalog

nugate Product Catalog Product Catalog Pneumatic activegate Control Stabilize your Process CAT-16-0019_EN-Rev03 EN 06/2017 Pneumatic Valve Gate Product Description nugate Hot Runner System Proportionally controlled Pneumatically

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the V-CEM5100 Flow Monitor Manufactured by: Codel International Ltd, Station Road Bakewell Great Britain Has been assessed by Sira Certification Service

More information

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly INTERNATIONAL STANDARD ISO 22827-1 First edition 2005-10-15 Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Part 1: Laser assembly Essais de réception pour

More information

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE

More information

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network Distributed Generation (greater than 10kW) Connecting to Vector s electricity network Important information about installing distributed generation with capacity greater than 10 kilowatts Purpose of this

More information

10.6 Schedule of Accreditation

10.6 Schedule of Accreditation Product Certification Body Accreditation is accredited by the GCC Accreditation Center () in accordance with the recognized International Standard, Conformity assessment -- Requirements for bodies certifying

More information

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual VoCALL - CFVCC5 Compact 5 Line Exchange Unit Installation & Commissioning Manual Introduction A VoCALL Emergency Voice Communications System (EVCS) is a fixed, secure, bi-directional, full duplex voice

More information

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING Page 1 of 10 CONTENTS 1 SCOPE 2 DEFINITIONS 2.1 SURGE ARRESTER 2.2 GAPLESS METAL-OXIDE SURGE ARRESTERS 2.3

More information

GAISER 4000 STEAM CLEANER OPERATOR MANUAL

GAISER 4000 STEAM CLEANER OPERATOR MANUAL GAISER 4000 STEAM CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

GS100M Gas Detector. Technical Specification

GS100M Gas Detector. Technical Specification GS00M Detector Application Duomo is recognised within the Gas industry for providing a comprehensive range of low cost, high reliability gas detection for many applications. We have installed and commissioned

More information

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL 3500 CONVENTIONAL FIRE ALARM CONTROL PANEL INSTALLATION AND COMMISSIONING MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax:

More information