1 zonex enclosures Equipment PROTECTION hazardous locations

2 ZONEX Enclosures An expanded offering of Hinge- and Screw-cover Enclosures for hazardous locations. ATEX directive 94/9/EC and IECEX certified for Zone 1 Zone 2 rated areas. The ZONEX Enclosure family delivers reliable protection in a versatile platform. The newly expanded line of ZONEX ATEX-Certified* Enclosures includes the certifications, styles and sizes your application requires. ZONEX hinge-cover and screw-cover enclosures are designed for use in applications where increased safety protection (Ex e), is acceptable to safely house electrical components in Zone 1- and Zone 2-rated areas. These enclosures are not intended for use in explosion-proof or flame-proof (Ex d) applications. Hinge-cover versions are ATEX and IECEX certified, and available in 16 standard sizes. The screw-cover versions provide also ATEX and IECEX certification and are available in five sizes. Additional certifications such as AEx and KOSHA will be available soon (AEx certified hingecover version is already available as non-standard model). Hinge-cover versions in standard sizes ranging from 300 x 300 x 150 mm to 900 x 600 x 210 mm ZONEX Screw-Cover Model Easy-to-remove cover Type 316 stainless steel with capivated Type 316 stainless steel cover screws for corrosion resistance Screw-cover versions in standard sizes ranging from 102 x 102 x 76 mm to 254 x 254 x 127 mm Enhanced customization options allow you to specify the exact enclosure solution you need. Options include: material changes, dimension changes, paint options, holes and cutouts, population of ATEX-certified terminal blocks and more. * For more information about ATEX-certification visit: index_en.htm Bonding provisions, screw-cover style 6-mm internal/external brass bonding provision Wall-mounting brackets, screw-cover style Welded-on, full-width top and bottom wall-mount brackets for easy installation 2 ZONEX ENCLOSURES

3 ZONEX Hinge-Cover Model Wall-mounting brackets Heavy-duty 2,5-mm welded-on brackets, horizontal or vertical, for easy site installation 210-degree opening door that is easily removed by pulling clip style hinge pins Bonding provisions 10-mm brass internal/external bonding provisions Continuous gasket seal on the door and gland plate for protection against water and dust ingress Internal studs for panel or DIN rail mounting Type 316 stainless steel 3mm double bit ¼-turn for easy access and closure Full-size gland plate 3-mm thick (12 gauge) flat bottom gland plate with bonding stud and continuous gasket seal ZONEX ENCLOSURES 3

4 Selection and specification of a ZONEX Enclosure to meet your application requirements Certified for your application requirements ZONEX enclosures deliver a robust solution for termination and junction enclosure applications in potentially hazardous locations, including: Petroleum and chemical processing Water treatment processing Pharmaceutical processing Grain processing There are 2 ways to determine the correct size ZONEX Enclosure for populated terminal blocks (see page 8): Method 1: Maximum Terminal Block Count Method 2: Maximum Dissipated Power (watts) * NOTE - All selection methods must adhere to maximum dissipated power for selected enclosure size. Modification and Customization Hoffman excels at modifying and customizing ZONEX products to your specifications while maintaining ATEX and IECEX certifications. Contact your local Hoffman sales office or distributor for complete information. Hoffman offers: Material changes: Type 304 stainless steel, aluminum, mild steel Gasket changes: High-temperature silicone gasket Holes and cutouts Paint DIN rails Terminal block installation and marking Ground bars Tagging Accessory installations Zero to four gland plates* *Hinge-cover enclosures only Certification Markings ATEX IECEX AEx / Ex II 2 G D Ex e IIC T6 Gb (Ta -20 C to +40 C) Ex tb IIIC T85 C Db IP 66 II 2 G D Ex e IIC T5 Gb (Ta -20 C to +55 C) Ex tb IIIC T100 C Db IP 66 Ex e IIC T6 Gb (Ta -20 C to +40 C) Ex tb IIIC T85 C Db IP 66 Ex e IIC T5 Gb (Ta -20 C to +55 C) Ex tb IIIC T100 C Db IP 66 UL File No. E67546: Class I, Zone I AEx e IIC Tamb -20 C to +60 C Ex e IIC Tamb -20 C to +60 C 4 ZONEX ENCLOSURES

5 ATEX Directive and Classification System Since 2003, manufacturers across the European Union (EU) have been obliged to comply with strict new EU directives governing safety in explosive atmospheres. Called ATEX (from the French ATmosphères EXplosives), ATEX Directive 94/9/EC has an impact not only on European manufacturers, but also on non-european makers of industrial equipment wishing to sell in Europe. Two of the most common classification systems for hazardous locations are the Zone Classification system used by the European Union (EU) and the International Electrotechnical Commission (IEC), and the NEC Division Classification system. Area Classification US CA Flammable Substance Present Continuously Flammable Substance Present Intermittently Flammable Substance Present Abnormally IEC / EU Zone 0 Zone 1 Zone 2 NEC 505 Zone 0 Zone 1 Zone 2 NEC 500 Division 1 Division 2 CEC Section 18 Zone 0 Zone 1 Zone 2 CEC Annex J Division 1 Division 2 IEC classification per IEC EU classification per EN US classification per ANSI/NF PA 70 National Electrical Code (NEC ) Article 500 or Article 505 CA classification per CSA C22.1 Canadian Electrical Code (CEC) Section 18 or Annex J Zones Articles 505 and 506 of the NEC refer to zone classifications. Refer to the Technical Information section of the Specifier s Guide for specific definitions and additional information. Zone 2 /22 Safe Area Hoffman s ATEX enclosures are not intended for use in explosion-proof or flame-proof (Ex d) applications. ATEX Marking Directive (94/9/EC) European Explosive Atmosphere Symbol II 2 G D Equipment Group Equipment Category Gas Dust Zone 1 / 21 Zone 0 / 20 Ex e II T6 European Explosive Atmosphere Protection Concept Protection Method Gas Group Temperature Class Zone 0 / 20 Zone 1 / 21 Zone 2 / 22 Zone 0 / 20 Permanently or frequently hazardous over long periods Occasionally hazardous Rarely or temporarily hazardous Zones 20, 21 and 22 are dust Increased Safety Ex e It is assumed that the hazardous atmosphere penetrates to the enclosure interior and explosion is prevented by ensuring that either in normal operation or under fault conditions: There are no arcs or sparks No components or parts temperatures exceed the temperature limit of the corresponding temperature class Notes: ATEX and intrinsically safe certified terminal blocks can be installed in populated enclosures IECEX populated enclosures require IECEX certified components specifically listed in Certification (see IECEX SIR for more detail) Contact your local Hoffman sales office or distributor for complete information All three elements of the fire triangle must be present for ignition to occur. Ignition Source Air/Oxygen Flammable/ Combustible Substance ZONEX ENCLOSURES 5

6 ZONEX screw-cover atex-certified enclosures H+25,4 H-12,7 H-12,7 (BODY OPENING) 3,2 W 2,8 2,8 H 12,7 2,0 M5 D Y Y W-22,6 W-12,7 (BODY OPENING) 16,0 D-23,8 8,6 Y-Y W B W-50 8,6 SPECIFICATIONS: Type 316 stainless steel, 320 grain brushed finish on exterior surfaces Welded-on, full-width top and bottom wall-mount brackets for easy installation 6-mm internal/external brass bonding provision Type 316 stainless steel captivated cover screws for corrosion resistance One-piece continuous gasket for protection against water and dust ingress Internal weld nuts provided for panel or DIN rail installation Mounting plate included H-36,4 H A SCREW-COVER ATEX (Standard Sizes) Catalog Number Actual Dimensions - mm A - Height B - Width C- Depth EXE SS6E EXE SS6E EXE SS6E EXE SS6E EXE SS6E ZONEX ENCLOSURES

7 ZONEX hinge-cover atex-certified enclosures SPECIFICATIONS: Type 316 stainless steel, 320 grain brushed finish on exterior surfaces Type 316 stainless steel 3mm double bit ¼-turn insert(s) for easy access and closure 210 degree opening door that is easily removed by pulling clip style hinge pins Heavy-duty 2,5-mm welded-on brackets, horizontal or vertical, for easy site installation 3-mm thick (12 gauge) full-size bottom gland plate with bonding stud Fabricated and formed entries for gland plate screws provide quick and easy installation Continuous gasket seal on the door and gland plate for protection against water and dust ingress 10-mm brass internal/external bonding provision Mounting plate included P Q Y-Y 20,8 W W-41,6 (BODY DOOR OPENING) 2,5 D 19,4 Y 31,8 W W-63,5 11,0 H H-41,6 (BODY DOOR OPENING) M8 x 1,25 H+31,8 H 22,5 A B 13,4 20,8 28,9 D-49,8 Y 22,5 13,8 Catalog Number Actual Dimensions - mm A - Height B - Width C- Depth EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61E EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE EXE SS61HE ZONEX ENCLOSURES 7

8 selection of zonex enclosures by Terminal Block Count & Power Determine the correct size ZONEX Enclosure for populated terminal block: N by Maximum Terminal Block Count (known wire size/ match terminal block size) p by Maximum Power (watts) 1. Refer to Power and Terminal Block Matrix appropriate for selected model (screw-/hinge-cover) 2. Find a terminal block quantity less than or equal to required in the shaded areas associated with your chosen terminal block manufacturer 3. Select enclosure size 4. Use calculating power and amperage formula to verify conformance to standard 5. If maximum power is exceeded by terminal block count and amperage, select an enclosure with higher power and re-calculate Specifying enclosures with terminal block population ATEX- and IECEX-certified terminal blocks from Phoenix and Weidmuller are referenced in tables Any ATEX or IEXEX hazardous location certified terminal block may be selected and installed in ATEX-certified applications Only the table referenced terminal blocks may be specified for IECEX populations and certification Combinations of different terminal block sizes and quantities may be selected for population All terminal block installation applications need to use the CALCULATING POWER and AMPERAGE formula and associated tables on page 10 to verify compliance with final intended amperage of application and power rating of selected enclosure 1. Refer to Power and Terminal Block Matrix appropriate for selected model (screw-/hinge-cover) 2. Find maximum power required in shaded areas associated with your chosen terminal block manufacturer 3. If terminal block quantity for maximum power is insufficient, continue down and across rows until requirement is met; this provides the smallest enclosure to meet maximum power and amperage needs 4. Use calculating power and amperage formula to verify conformance to standard 5. If maximum power is exceeded by terminal block count and amperage, select an enclosure with higher power and re-calculate R Calculating Power and Amperage using combined terminal resistance factor (see page 10) Calculation of power/amperage/number of terminal blocks in accordance with EN :2007, ANEX E, E.2 P = N x R x I 2 or I = [P/(N x R)] or N=P/(R x I 2 ) Where: P is the total dissipated power (watts) N is the total number of terminals I is the current (amps) R is the sum of terminal resistance (Rt) and wire resistance (Rw) Terminal Wire Size, Voltage and Resistance (Rt) Data Manufacturer Phoenix Weidmuller (SAK/WDU) Model UK1.5 UK3 UK5 UK Terminal Wire Size Range (mm 2 ) Terminal Voltage (Volts) Terminal Resistance Rt (Ohm) 0.14 to to to to to to to to x10-04 x10-04 x10-04 x10-04 x10-04 x10-04 x10-04 x10-04 Power & Terminal Block Quantity Matrix SCREW-COVER ZONEX (Standard Sizes) N MAXIMUM TERMINAL BLOCKS Quantity Offerings per Enclosure p MAXIMUM POWER Dissipation (Watts) Phoenix Weidmuller (SAK/WDU) DIN Rail T6 at Actual Dimensions (mm) Qty Tamp T5 at Tamp UK1.5 UK3 UK5 UK = +40 C = +55 C Height Width Depth Catalog Number W 3.8 W EXE SS6E W 6.9 W EXE SS6E W 6.9 W EXE SS6E W 9.6 W EXE SS6E W 9.6 W EXE SS6E ZONEX ENCLOSURES

9 Power & Terminal Block Quantity Matrix HINGE-COVER ZONEX (Standard Sizes) N MAXIMUM TERMINAL BLOCKS Quantity Offerings per Enclosure MAXIMUM POWER Dissipation (Watts) Phoenix Weidmuller (SAK/WDU) DIN Rail T6 at Tamp T5 at Tamp Actual Dimensions (mm) UK1.5 UK3 UK5 UK Qty = +40 C = +55 C Height Width Depth W 16.5 W W 18.5 W W 18.5 W W 23.5 W p 25.5 W 25.5 W W 28 W W 28 W W 28 W W 33 W W 33 W Catalog Number EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE EXE SS61E EXE SS61HE Color shaded areas are maximum physical quantity of terminal blocks that will fit enclosure, not necessarily the allowable quantity. Actual allowable quantity is determined by amperage and power allowed through provided mathematical formula. * Maximum dissipated power based on screw type terminal blocks. Weidmuller 2.5 and smaller wire size limited to 15 amperes. ZONEX ENCLOSURES 9

10 R Combined Terminal Resistance Factor This factor is used to determine the number of terminals that can be accommodated within the enclosure without exceeding the enclosure maximum wattage rating. The combined terminal resistance factor (R) is the sum of the individual terminal resistances (Rt) and the resistance of the cable core equal in length to the enclosure maximum diagonal (Rw). The core resistance has been defined in the standard BS EN Wattage to be Dissipated (P) = N x R x I² Total Number of Terminals (N) Combined Terminal Resistance Factor (R) = (Rt + Rw) the sum of terminal resistance [Rt] and wire resistance [Rw] Maximum Current (amps) used in the application = (I) Example: A customer wants to determine the number of WDU 2.5 terminals that could be used in an EXE SS61E enclosure rated at 17.5 watts (P) and at 10 amps (I). Solving for N in the above formula N = P / (R x I 2 ): N = 16.5 / ( x 10 2 ) N = 47 The maximum physical number of WDU 2.5 terminals that can be installed on a single rail is 29 and a total of 3 rails can be installed in the enclosure, therefore two rows of 23 terminal blocks could be accommodated in the enclosure. Combined terminal resistance factor MATRIX zonex enclosures (Standard Sizes) COMBINED TERMINAL RESISTANCE FACTOR Power ratings (Watts) Phoenix Weidmuller (SAK/WDU) UK1.5 UK3 UK5 UK EXE SS6E 3.8 W EXE SS6E 6.9 W EXE SS6E 6.9 W EXE SS6E 9.6 W EXE SS6E 9.6 W EXE SS61E EXE SS61HE 16.5 W EXE SS61E EXE SS61HE 16.5 W EXE SS61E EXE SS61HE 18.5 W EXE SS61E EXE SS61HE 18.5 W EXE SS61E EXE SS61HE 18.5 W EXE SS61E EXE SS61HE 18.5 W EXE SS61E EXE SS61HE 23.5 W EXE SS61E EXE SS61HE 23.5 W EXE SS61E EXE SS61HE 25.5 W EXE SS61E EXE SS61HE 28 W EXE SS61E EXE SS61HE 28 W EXE SS61E EXE SS61HE 28 W EXE SS61E EXE SS61HE 28 W EXE SS61E EXE SS61HE 33 W EXE SS61E EXE SS61HE 33 W EXE SS61E EXE SS61HE 33 W Integrator Partner Program In response to the increasing demand for integration of increased safety ATEX/IECEX approved enclosures, Hoffman has developed a certified integrator program that allows approved integration companies to provide value-added enclosure solutions on belfalf of the Hoffman brand. The Integrator Partner Program will: Allow enclosures to be populated with terminal blocks Modify enclosures with holes, cutouts and customer tags Provides ATEX/IECEX certificate for the assembly The Integrator Partner Program makes full use of Hoffman s industry-leading network of authorized distributors and their broad stock of enclosures to provide fast and efficient delivery. 10 ZONEX ENCLOSURES

11 ATEX-certified accessories Large-Volume ATEX Purge System Type Y, Z and Ex [pz] Designed to supply one or more enclosures with a protective gas supply, Hoffman s Ex [pz] purge system is designed and certified according to European requirements of ATEX Directive 94/9 EC and EN for Type Ex [pz] applications. ATEX-certified Ex [pz] purge systems reduce the classification in the protected enclosure from Zone 2 to nonhazardous, allowing the use and operation of general purpose equipment in the protected enclosure. Used as a Type Y purge reduces classification from Div. 1 to Div. 2. Type Z purge reduces classification from Div. 2 to Non-Hazardous. Purge/pressurization systems can be used for electronics, electrical equipment, motors and switch gear in wall-mount to large enclosures, and also meet the demands of rack-mounted instrumentation, video displays, programmable controllers, computers, printers, recorders and measurement and calibration equipment. Available for 90 cubic feet maximum enclosure volume in vertical mount (VM) or horizontal mount (HM) models. Industry Standards (volume up to 90 cubic feet) 3003 WPSA Type Y System UL and FM Certified: Class I, Division I Group A,B,C, and D/Zone 1, Groups IIB and H2 to Division 2/Zone 2 Type Z System UL and FM Certified: Class 1, Division 2 Group A,B,C, and D/Zone 2, Groups IIB and H2 to Non-hazardous ATEX Certified II 3 (3) G Ex [pz] II, -29 C Tamb. 49 C Hazardous Location Thermostat For temperature control of heaters or low-temperature alarms in enclosures used in explosionhazardous areas, Hoffman s Hazardous Location Thermostat features compact design and a robust thermostatic bimetallic sensor element for >100,000 cycle service life. The thermostat is usually connected directly and switched without the need for additional relays and offers high switching capacity with small hysteresis (switching difference). Hazardous Location Heater Designed for use in hazardous locations where electronic components require protection from condensation and corrosion, sudden temperature drops and low temperatures, Hoffman s Hazardous Location Heater offers maintenancefree, high-performance heating with a large convection surface, an extruded aluminum heat sink and VAC operation. Lock INSERTS (with key) Lock inserts are field-installable. Stainless steel material and different key locking systems provides maximum protection for your equipment. HAZARDOUS LOCATION BREATHER DRAINS Hazardous Location Breather Drains prevent moisture build-up within hazardous approved enclosures while maintaining enclosure UL Type rating. Drains are to be used when an enclosure is subject to fluctuations in temperature which can lead to the formation of condensation and a subsequent moisture build-up. These drains allow air within an enclosure to breathe with the surrounding atmosphere, preventing condensation and any potential damage to electrical equipment. HAZARDOUS LOCATION WINDOW KITS Hazardous Location Window Kits are designed to be used on Increased Safety (Ex e) enclosures in ATEX or IECEx Zone 1 or 2 hazardous areas. These window kits are made with a robust heavy-gauge Type 316 stainless steel frame and a silicone gasket to ensure a dust-, oil-, and water-tight seal. Designed for use as viewing windows, these window kits are ideal for visibility of internal enclosure components. The window are easily installed by making a cutout in the enclosure and attaching the window and frame with included mounting hardware. ZONEX ENCLOSURES 11

12 SKARPNÄCK MINNEAPOLIS TORONTO MOSCOW DZIERZONIOW HEMEL HEMPSTEAD WARSAW BETSCHDORF STRAUBENHARDT LAINATE ISTANBUL QINGDAO SHIN-YOKOHAMA DUBAI SHANGHAI MEXICO D.F. BANGALORE SINGAPORE BOITUVA SĀO PAULO RIO DE JANEIRO For more information and to contact us, go to: Europe North America middle east & INDIA Asia Straubenhardt, Germany Tel: Minneapolis, MN Tel: Dubai, United Arabian Emirates Tel: Shanghai, P.R. China Tel: Betschdorf, France Tel: Radford, VA Tel: Bangalore, India Tel: Singapore Tel: Warsaw, Poland Tel: Mexico, D.F. Tel: Istanbul, Turkey Tel: Shin-Yokohama, Japan Tel: Dzierzoniow, Poland Tel: Toronto, Canada Tel: Seoul, Korea Tel: Hemel Hempstead, Great Britain Tel: Lainate, Italy Tel: Moscow, Russia Tel: Pentair, Hoffman and Design with Confidence are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners Pentair. Bro-00179

COOL COMBINATION EQUIPMENT PROTECTION SOLUTIONS INDUSTRIAL ENVIRONMENTS

COOL COMBINATION EQUIPMENT PROTECTION SOLUTIONS INDUSTRIAL ENVIRONMENTS COOL COMBINATION EQUIPMENT PROTECTION SOLUTIONS INDUSTRIAL ENVIRONMENTS COOL COMBINATION WITH ITS MODULAR ENCLOSURE SYSTEMS FROM HOFFMAN AND AIR CONDITIONERS FROM MCLEAN, PENTAIR OFFERS COMPLETE PROTECTION

More information

Oil & gas. design with confidence. Pentair Equipment protection. harsh & Hazardous Applications

Oil & gas. design with confidence. Pentair Equipment protection. harsh & Hazardous Applications Oil & gas SOLUTIONs design with confidence Pentair Equipment protection harsh & Hazardous Applications We ve got you covered In the most harsh and hazardous environments, anywhere on the globe, Hoffman

More information

Food and Beverage DESIGN WITH CONFIDENCE EQUIPMENT PROTECTION. Sanitary Applications

Food and Beverage DESIGN WITH CONFIDENCE EQUIPMENT PROTECTION. Sanitary Applications Food and Beverage DESIGN WITH CONFIDENCE EQUIPMENT PROTECTION Sanitary Applications sanitary practices under the microscope With the passing of the Food Safety Modernization Act (FSMA) in early 2011, there

More information

COMMERCIAL CONSTRUCTION ENGINEERED ELECTRICAL & FASTENING SOLUTIONS COMMERCIAL APPLICATIONS

COMMERCIAL CONSTRUCTION ENGINEERED ELECTRICAL & FASTENING SOLUTIONS COMMERCIAL APPLICATIONS COMMERCIAL CONSTRUCTION ENGINEERED ELECTRICAL & FASTENING SOLUTIONS COMMERCIAL APPLICATIONS THE PATH TO MOUNTING, WIRING AND INSTALLING ELECTRICAL DEVICES JUST GOT SHORTER Commercial contractors responsible

More information

AVAILABILITY EASE OF INSTALLATION SERVICE. SpectraCool Slim Fit Air Conditioner. Easy to Specify and Ready to Use

AVAILABILITY EASE OF INSTALLATION SERVICE. SpectraCool Slim Fit Air Conditioner. Easy to Specify and Ready to Use AVAILABILITY EASE OF INSTALLATION SERVICE SpectraCool Slim Fit Air Conditioner Easy to Specify and Ready to Use The Ultimate in Cooling Convenience Specially designed and developed to meet the requirements

More information

Varistar LHX 3 Air/Water Heat Exchangers

Varistar LHX 3 Air/Water Heat Exchangers Varistar LHX 3 Air/Water Heat Exchangers LHX 3Main CataloguePart number in bold face type: ready for despatch within 2 workin g dayspart number in normal type: ready for despatch within 10 working days

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition

More information

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. curus Component Recognized; File No. E IP 20 TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Detection of carbon dioxide Dräger Polytron 5720 IR Detection of carbon dioxide The Dräger Polytron 5720 IR is a cost effective explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Enclosure Cooling Solutions

Enclosure Cooling Solutions Enclosure Cooling Solutions nvent HOFFMAN Enclosures and Cooling FOR COMPLETE AUTOMATION PROTECTION nvent HOFFMAN Cooling (formerly McLean) helps create optimal conditions for the reliable operation of

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.

More information

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017 Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below

More information

Guide to Intrinsically Safe Portable Radios

Guide to Intrinsically Safe Portable Radios Guide to Intrinsically Safe Portable Radios An overview of common IS standards www.taitradio.com GUIDE TO INTRINSICALLY SAFE PORTABLE RADIOS SUMMARY The development of equipment for explosive atmospheres

More information

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors Dräger Polytron 8100 EC Detection of toxic gases and vapors The Polytron 8100 EC is Dräger s top of the line explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

How Limit Switches Can Stop Machines from Going Boom

How Limit Switches Can Stop Machines from Going Boom How Limit Switches Can Stop Machines from Going Boom A Honeywell White Paper Safety is one of the top criteria when selecting a limit switch for hazardous location environments. In many cases, these switches

More information

custom cabinets and junction boxes

custom cabinets and junction boxes PROCESS AUTOMATION custom cabinets and junction boxes Pepperl+Fuchs Your partner in system design remote i/o enclosures solutions for Remote I/O 2 Remote i/o enclosures FIELD junction box solutions for

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma

More information

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN. User s Manual AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type Contents 1. ATEX Documentation 2. Explosion Proof Type Instrument 2.1 ATEX...2 2.2 IECEx...7 1 2 Integral

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

S T R I T T & P R I E B E I N C.

S T R I T T & P R I E B E I N C. Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

SYSTEMS PRODUCT OVERVIEW

SYSTEMS PRODUCT OVERVIEW PROCESS AUTOMATION THE LEADERS IN PURGING TECHNOLOGY PURGE AND PRESSURIZATION SYSTEMS PRODUCT OVERVIEW SERIES 6000 SERIES 5000Q SERIES 3000 SERIES 1000 MAKE YOUR AREA SAFE ANYWHERE IN THE WORLD GLOBAL

More information

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths Product Description The XB, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The XB is available with either CSA C/US or CE/ATEX approvals.

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets Harness the power of collaborative innovation MANET-SCHULTZ OF AMERICA S P E C I A L I S T S I N E L E C T R O M A N E T I C E V I CES Magnet-Schultz of America, Inc. 401 Plaza rive Engineered for safety

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas Intrinsic Safety Intrinsically Safe Solutions Accurate Weighing in Hazardous Areas Accidents in hazardous areas can have dramatic consequences for businesses in terms of both human life and profit. Intrinsically

More information

ELECTRICAL EX EQUIPMENT

ELECTRICAL EX EQUIPMENT ELECTRICAL EX EQUIPMENT in hazardous areas Enclosures Reliable Customized Solutions Leader in Explosion Proof Protections CB Control Panel Configuration - Gas group IIB / Dust group IIIC Ex d enclosures

More information

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure. Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure. Video monitoring under extreme conditions Security Products from Siemens is

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications Crouse-Hinds Enclosures High performance, high reliability enclosures for global applications Crouse-Hinds Enclosures High Performance, high reliability enclosures for global applications Eaton s Crouse-Hinds

More information

PANELBOARD PROTECTION ON A GLOBAL SCALE

PANELBOARD PROTECTION ON A GLOBAL SCALE PANELBOARD PROTECTION ON A GLOBAL SCALE INTRODUCTION WHY? No matter what environment, location or power requirement, Appleton panelboards have you and your facility covered. From a petrochemical plant

More information

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3490 Series 4 20 ma + HART Compatible Controller 00825-0200-4841, Rev AB Rosemount 3490 Series 4 20 ma + HART Compatible Controller Failure to follow safe installation guidelines could result in death or serious injury The Rosemount 3490 Series Control

More information

4) Intrinsic Safety Certification

4) Intrinsic Safety Certification INSTRUCTION MANUAL Minialert Intrinsically Safe Round Combined Unit Section Volume Control Tone Generator S2 S3 Tone Selection Switches Fig 1 Simplified block diagram The combined unit is CE marked for

More information

WALL-MOUNT SOLUTIONS DESIGN WITH CONFIDENCE

WALL-MOUNT SOLUTIONS DESIGN WITH CONFIDENCE WALL-MOUNT SOLUTIONS DESIGN WITH CONFIDENCE EQUIPMENT PROTECTION COMMUNICATIONS PROTECT YOUR ELECTRONICS INVESTMENT WITH THE INDUSTRY S WIDEST ARRAY OF WALL-MOUNT SOLUTIONS PENTAIR S HOFFMAN BRAND WALL-MOUNT

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

official distributor of Newson Gale Ltd.

official distributor of Newson Gale Ltd. Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container

More information

DESCRIPTION. 42 mm. 125 mm

DESCRIPTION. 42 mm. 125 mm RMM2-DI TRACE-HEATING REMOTE MONITORING MODULE FOR DIGITAL INPUTS DESCRIPTION 125 mm 60 mm The Remote Monitoring Module for Digital Inputs (RMM2-DI) provides the capability for the Raychem NGC controller

More information

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

SmartPower Solutions. Quick Start Guide , Rev CA March 2015 SmartPower Solutions 00825-0100-4701, Rev CA NOTICE This guide provides basic guidelines for the SmartPower family of products. It does not provide instructions for detailed configuration, diagnostics,

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY Cell Phones Smartphones PDA integrating people, products and processes Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2385571 Project 2447891 Issued to: Mine Safety Appliances 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Issued by: Jocelyn Jens Product Group

More information

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8310 Stationary gas detector (DSIR) Stationary gas detector (DSIR) SIMPLE INSTRUMENT MANAGEMENT POISON-RESISTANT AND FAIL-SAFE THANKS TO DIGITAL COMMUNICATION The DrägerSensor IR offers several benefits: technological advantages such as

More information

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017 Rosemount 0085 Pipe Clamp Sensor Assembly Quick Start Guide 00825-0100-4952, Rev DC Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0085 Pipe Clamp Sensor. It does not provide

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request) Type Y, Z & Ex [pz] purge and pressurization system 3003 Features Assembly NFPA 496, ISA 12.4, and ATEX standards Optional alarm output indicates air lock failure Optional differential pressure switch

More information

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED Hazardous Area LED Lighting Hazard Gard LED Luminaires Hazard Gard EVLL LED Hazard Gard EVLL LED Safe. Reliable. Efficient. Featuring the industry's broadest range of LED luminaires for harsh and hazardous

More information

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview About Us Automation is our world. A perfect application solution is our goal. A willingness

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Rosemount 3490 Series

Rosemount 3490 Series Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall

More information

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation. Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

Understanding Hazardous and Explosion-Protection Environments

Understanding Hazardous and Explosion-Protection Environments Understanding Hazardous and Explosion-Protection Environments Explosions occur when a mixture of oxygen and explosive substances develop into explosive gases. When the concentration of a substance in air

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C PSD1001C INSTRUCTION MANUAL SIL 3 SIL 2 IIB Group Power Supply for Hazardous Area Equipment DINRail Model PSD1001C PSD1001C SIL 3 SIL 2 IIB Group Power Supply for hazardous Area Equipment ISM006510 General

More information