1 Radon monitoring system in the Kamioka mine Guillaume Pronost on behalf of the Super-Kamiokande collaboration Kamioka Observatory, ICRR, The University of Tokyo JPS Miyazaki conference, September 21th 2016 (Supported by KAKENHI Grant-in-Aid for Scientific Research on Innovative Areas )

2 Why measuring Radon? Radon is a radioactive gas which tend to accumulate indoors (and so underground). Radioactivity from Radon can lead to health issue in case of high exposure. Radioactivity from Radon is a background for high precisions experiments looking for low energy physics like the ones present in the Kamioka mine: Super-K, XMASS, CANDLES, KamLAND, etc. Monitoring the Radon concentration allows to protect the health of the researchers and technicians working in the mine and to control the background coming from Radon. JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

3 Radon detector Radon detector design: 10cm 1L detector 17cm USB Humidity sensor (new) RaspberryPi ADC Electronics case: 120 V H.V., ±12V input signal, RaspberryPi ADC I Data taking and upload performed by the RaspberryPi (RP) I Data analysis performed automatically on the Radon data server JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

4 Radon detection concept: electrostatic collection method 120 V amp. 218 Po + N P α 21X Po + RaA (α 1 ) 218 Po RaC (α 2 ) 214 Po 222 Rn RaF (α 3 ) 210 Po GND Air Filter SUS mesh Air Collection of positive ions from 222 Rn decay chain on the PIN photo-diode: 222 Rn α 218 Po + α Pb + β 214 Bi + β 214 Po Po + α Pb + β 210 Bi + β 210 Po + α Pb + Concentration = RaC counts Calibration Factor(Humidity, time data taking ) JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

5 Data analysis: new software New analysis software developed in the past months, based on ROOT/CERN Automatically computing the radon concentration from the detector data Calibration factor determined using the current Humidity (from sensors) Radon count to Radon concentration factor Factor (Bq/m^3)/(RaC'/10min) Relative Humidity (%) JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

6 Monitoring in the Mine 22 detectors in the mine for Rn monitoring (18 with RaspberryPi system) 11 dedicated to Super-K areas KamLAND CANDLES XMASS SK Atotsu tunnel ( 2 km) Rn Hut EGADS JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

7 Monitoring in the Mine 22 detectors in the mine for Rn monitoring (18 with RaspberryPi system) 11 dedicated to Super-K areas KamLAND CANDLES XMASS SK Atotsu tunnel ( 2 km) Rn Hut EGADS JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

8 Radon monitoring in the SK area: SK Dome SK Dome Right SK Dome Center SK Dome Left 1day-averaged radon concentration Radon concentration appears to be below 148 Bq/m 3 in SK Dome 148 Bq/m 3 correspond to 4 pci/l: US limit for indoor Rn concentration JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

9 Monitoring of the fresh air Fresh air is brought from outside by a air pipe in the mine, extracted at 100 m 3 /min We monitor the output of this air pipe in the SK dome Rn concentration from Duct Air detector fluctuates > 148 Bq/m 3 mostly around midnight Leak in the air pipe? JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

10 Fresh air issue: investigations New detector installed at the input of the air pipe (in the Rn Hut) Concentration in Fresh air input (Bq/m3) Concentration in Fresh air output (Bq/m3) Visible correlations between the input and the output of the fresh air pipe We can conclude that we have no leak in the pipe Additionnal investigations needed to understand the fluctuations JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

11 Radon monitoring in the SK area: Entrance Room and Front of Shift room Door was let opened 20 minutes Golden week WE Official visits WE WE WE WE WE Front of SK Shift Room SK Entrance Room 1h-averaged radon concentration In front of SK Shift room c Rn < 148 Bq/m 3 In Entrance room: fluctuations between safe values and very high values Each time the Entrance door is opened, dirty air comes inside We need to minimize the time when this door is opened JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

12 Radon monitoring in the SK area: Atotsu tunnel Atotsu Tunnel 1h-averaged radon concentration We are monitoring the Radon concentration in the tunnel Rather high Radon concentration since the detector is running (beginning of April) However, some huge decreases of the concentration happened some times (mostly during night) JPS Miyazaki conference, September 21th /14

13 Radon monitoring in the SK area: Atotsu tunnel Radon concentration Temperature in Kamioka-cho Correlation between Radon concentration and outside Temperature Our hypothesis: Cold outside temperature low outside pressure Mine air going out from the vertical pit of Kamioka mine Wind in Atotsu tunnel coming from outside Need to use the data of the wind in Atotsu tunnel to verify Temperatures from Japan Meteorological Agency website JPS Miyazaki conference, September 21th /14

14 Radon monitoring in the SK area: Atotsu tunnel Outside Inside Inside Outside We now have the data of the wind sensor in Atotsu tunnel Unfortunately, the phenomenon did not happen again (can be expected in end of September / October when temperature will be lower) JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

15 New radon monitoring in the mine: Summary 22 1L Rn detectors deployed inside the mine 11 in Super-K experimental areas All the areas of the mine are monitored 75% equipped with Humidity/Temperature sensor (10 USB sensors in SK areas) New data analysis software developed, based on ROOT/CERN We demonstrated that there is no visible leak in the fresh air pipe We observed some fluctuations in the tunnel concentration which seems to be linked to the outside temperature. Future plans: Investigate the high Radon values in the input of the fresh air pipe Investigate on the fluctuations of the Rn concentration in the tunnel JPS Miyazaki conference, September 21th /14

16 Backup Backup JPS Miyazaki conference, September 21th /14

17 Fresh air issue: investigations I Analyze of the detector raw data with our new analysis software: Fresh air output Old analysis system Same day/night fluctuations, but lower concentration Issue in the way the concentration was computed with the old system However, still higher than expected JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

18 Fresh air issue: investigations II We proposed the following in order to investigate this issue: Settle a new radon detector in the US Radon Hut monitor the input and the output Radon concentration from air pipe Air Pipe RP RP Rn D New systems Not to scale Rn D Pump H/T H/T Super-K Dome 2 km US Rn Hut JPS Miyazaki conference, September 21th /14 pronost@km.icrr.u-tokyo.ac.jp

Development of the Groundwater Radon Detector

Development of the Groundwater Radon Detector Development of the Groundwater Radon Detector Japan-Taiwan International Workshop on Hydrological and Geochemical Research for Earthquake Prediction Date Sep.-24,2002 Place AIST (Tsukuba) Educational Research

More information

Development of high sensitivity radon detectors

Development of high sensitivity radon detectors Nuclear Instruments and Methods in Physics Research A 421 (1999) 334 341 Development of high sensitivity radon detectors Y. Takeuchi *, K. Okumura, T. Kajita, S. Tasaka, H. Hori, M. Nemoto, H. Okazawa

More information

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY DOWNLOADS DESCRIPTION BATTERY LIFE Approximately 1.5 years of continuous monitoring 3 replaceable AAA batteries DISPLAY 1-day, 7-day, and long-term average radon level FUNCTIONS Reset button Mode button

More information

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points Topic 4 - Audio 46 Key Points : Measures taken to increase confidence in results. Quality Assurance: Program that assures that measures are being done and in a timely manner. Precision: How close measurements

More information

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement RN53 Radon Detector RN53 - For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement Description The RN53 Radon Detector operates on the method of electrostatic collecting of the radon

More information

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions. Personal Alpha/Beta Continuous Air Monitor (CAM) The pocamon (personal online continuous air monitor) monitors continuously the breathing air to detect airborne radioactive aerosols (LLRD). Typical application

More information

Measurement Devices. Topic 5 - Audio 56

Measurement Devices. Topic 5 - Audio 56 Topic 5 - Audio 56 Other Classifications Passive devices: Air diffuses in No power required for sampling Active devices: Requires power Pumps air through filter Key Points - Devices What lab sees: Different

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: The Lane School 500 N Elm St Hinsdale, IL 60521 Survey Date: April 17, 2012 to April 19, 2012 Initial Test

More information

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT [Kim* et al., 4(2): February, 17] ISSN: 234-97 PERFORMANCE IMPROVEMENT OF RADON COUNTERS 1 Yong-Cheol Kim, *2 Gyu-Sik Kim 1,2 Professor, Dept. of Electrical and Computer Eng., University of Seoul, Korea

More information

Quality and Technology - Made in Germany -

Quality and Technology - Made in Germany - Quality and Technology - Made in Germany - TRACERLAB GmbH Aachener Str. 1354 50859, Koeln, Germany Tel.: +49 (0) 2234-942397 Fax.: +49 (0) 2234-942398 E-mail: asktracerlab@tracerlab.com Internet: www.tracerlab.com

More information

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti Radon in the Living Environment, 25 RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti Department of Environmental

More information

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Portable Alpha/Beta Continuous Online Air Monitor (CAM) Aer 5000 Desktop Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors the ambient air continuously to detect airborne radioactive aerosols (LLRD). Typical application fields are

More information

835 S. Canyon Blvd., John Day, OR 97845 Phone: (541) 575-1349 Fax: (541) 575-3601 Robert Waltenburg-Superintendent waltenburgr@grantesd.k12.or.us Stacie Holmstrom Deputy Clerk holmstroms@grantesd.k12.or.us

More information

Radon Environmental Health Program Health Canada, Alberta Region. Bradley Hameister October 4, 2011

Radon Environmental Health Program Health Canada, Alberta Region. Bradley Hameister October 4, 2011 Radon Environmental Health Program Health Canada, Alberta Region Bradley Hameister October 4, 2011 Question What is radon? 2 RADON Naturally occurring radioactive gas that comes from uranium in the ground

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Walker School 120 S Walker Clarendon Hills, IL 60514 Survey Date: April 25, 2012 to April 27, 2012 Initial

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

RADON TESTING: HEALTH GUIDELINES

RADON TESTING: HEALTH GUIDELINES RADON TESTING: HEALTH GUIDELINES What is the Health Canada recommended action level for radon mitigation? The Health Canada recommended action level [also known as the reference level] is 200 Bq/m 3. What

More information

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application Aer 5200/5300 Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors continuously the ambient air to detect airborne radioactive aerosols (LLRD). Typical application fields are nuclear

More information

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science The world leader in serving science Instrumentation Post RDD Event Urban Reoccupancy James P. Menge PE Perception In the aftermath of a radiological emergency the public will see radiation and its potential

More information

Bethel School District Radon Testing Plan

Bethel School District Radon Testing Plan The 2015 Oregon Legislature passed House Bill (HB) 2931 so that elevated radon levels in Oregon schools would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167. As directed

More information

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR RADON PLAN The 2015 Legislature passed House Bill (HB) 2931 so that if elevated radon levels in Oregon schools existed they would be known. House Bill 2931 later became Oregon Revised Statute (ORS) 332.166-167.

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Monroe School 210 N Madison Hinsdale, IL 60521 Survey Date: May 7, 2012 to May 9, 2012 Initial Test RDS-R-002

More information

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc. Love the Lungs You re With 630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: October 20 2014 to October

More information

Radon and Thoron Measurements at Special Underground Circumstances

Radon and Thoron Measurements at Special Underground Circumstances Radon and Thoron Measurements at Special Underground Circumstances Tibor Kovács a*, Norbert Kávási b, Csaba Németh c, János Somlai a, Tamás Vigh d, Gábor Szeiler a, and Shinji Tokonami e, Hiroyuki Takahashi

More information

Radiation Monitoring Equipment

Radiation Monitoring Equipment Radiation Monitoring Equipment Sharon Paulka Regional Training Course RAF 3007-1 Namibia, 17-21 August 2009 International Atomic Energy Agency Types of Monitoring Both Occupational & Environmental Require

More information

Detectors used in the intercomparison

Detectors used in the intercomparison Detectors used in the intercomparison The second radon-in-field international intercomparison for passive measurement devices: dwellings and workplaces 21 22 september 2017 Campus Bovisa Politecnico di

More information

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT Contract #: per D. Boyer/ C. Fredrichs for Radon Testing Services Report of Radon Measurement Survey Date: November 16, 2018 Site: Shaker Schools, Shaker Heights, Ohio Onaway Elementary School and Woodbury

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Survey Report Client: Community Consolidated School District 181 Site Address: Elm School 6010 S Elm St Hinsdale, IL 60521 Survey Date: April 9, 2012 to April 11, 2012 Initial Test RDS-R-002

More information

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories October 2018 C-NRPP/PNCR-C 1 (855) 722-6777 c-nrpp.ca Canadian

More information

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon Radon Testing and Reporting Plan Tillamook School District #9 Tillamook, Oregon Introduction: In 2015, the Oregon Legislature passed Oregon Revised Statute (ORS) 332.166-167 which, in part, requires school

More information

Sonic V. Acoustic Pulse Reflectometry Technology. 21b Aharon Boxer Street, Nes-Ziona, , ISRAEL

Sonic V. Acoustic Pulse Reflectometry Technology. 21b Aharon Boxer Street, Nes-Ziona, , ISRAEL Sonic V Acoustic Pulse Reflectometry Technology The Sonic V Introduction The Sonic V is a 5 th Generation Acoustic Pulse Reflectometry inspection system for ultra-fast and reliable Inner diameter (ID)

More information

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc. Commercial Radon Survey Report Client: Community Consolidated School District 181 Site Address: Prospect School 130 N Prospect Clarendon Hills, IL 60514 Survey Date: April 23, 2012 to April 25, 2012 Initial

More information

Guide for Radon Measurements in Residential Dwellings (Homes)

Guide for Radon Measurements in Residential Dwellings (Homes) Guide for Radon Measurements in Residential Dwellings (Homes) Health Canada is the federal department responsible for helping Canadians maintain and improve their health. We assess the safety of drugs

More information

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON A.C. George and N. Bredhoff Radon Testing Corporation of America Elmsford, New York Abstract According to the US EPA, radon is the leading cause

More information

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS PROGRAm BC Lung Association The British Columbia Lung Association (BCLA) is one of the

More information

Ramon 2.2 Radon-Monitor

Ramon 2.2 Radon-Monitor Ramon 2.2 Radon-Monitor Applications Measurement Modes - Technology - Quality Extratech Engineering, Technology, Software & Training - by 3DLiFe srl Via Torraca, 76-85100 Potenza (PZ) Tel/Fax. (+39) 0971.21.432

More information

Measurement system for detection of Radon in building

Measurement system for detection of Radon in building Measurement system for detection of Radon in building Outline Properties of Radon Detection of ionised particles Measurement system for radon Properties of Radon Radon is a gaseous isotope ( 222 Rn) with

More information

C-NRPP Quality Assurance Guidance for Radon Test Devices

C-NRPP Quality Assurance Guidance for Radon Test Devices C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks

More information

European Commission approach with regard to radon

European Commission approach with regard to radon European Commission approach with regard to radon Åsa Wiklund National Expert in DG TREN/H.4 Radiation Protection EUROPEAN COMMISSION 1 Radon at the European Commission DG TREN DG RTD DG SANCO Joint Research

More information

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC Prepared for Lawler-Wood Housing, LLC Riverview Tower, Suite 2000 900 South Gay Street Knoxville, Tennessee Prepared by ORION Orion Environmental

More information

Radon. In Your Home SAMPLE

Radon. In Your Home SAMPLE Radon In Your Home About Radon What is radon? Radon is a radioactive gas that may be lurking in the air or drinking water in your home. As the second-leading cause of cancer, it s a silent killer. But

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD:

More information

Introduction...1 Specifications... 1 Limitations... 1

Introduction...1 Specifications... 1 Limitations... 1 Table of Contents Introduction...1 Specifications... 1 Limitations... 1 New Algorithms...2 Regions of Interest... 3 New Algorithm ROIs... 3 Calibration... 5 Update Interval... 5 K Factor... 5 Subscripts...

More information

ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS

ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS Knowledge of existing protocols and guidelines, coupled with equipment acumen can make for a successful endeavor

More information

Radiation Control and Monitoring System on the HTTR

Radiation Control and Monitoring System on the HTTR Radiation Control and Monitoring System on the HTTR Y. Minowa, T. Nakazawa, H. Kikuchi, T. Nomura and N. Sato Japan Atomic Energy Research Institute Oarai Research Establishment, Oarai-machi, Ibaraki-ken

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA - FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION Up to 6 WEEKS PRINTED RECORD (Optional)

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

Have any questions or comments that we didn t get to here? Please let us know! support.airthings.com

Have any questions or comments that we didn t get to here? Please let us know! support.airthings.com Airthings Wave Smart Radon Detector Operating Manual Version 2, May 2, 2018 Set up your Airthings device in 3 simple steps: 1. Download the Airthings Wave App, available on ios and Android 2. Create an

More information

Canberra icam: the worldwide alpha/beta air monitoring solution. James Forde-Johnston EMS Product Manager Japan User Group Meeting

Canberra icam: the worldwide alpha/beta air monitoring solution. James Forde-Johnston EMS Product Manager Japan User Group Meeting Canberra icam: the worldwide alpha/beta air monitoring solution James Forde-Johnston EMS Product Manager Japan User Group Meeting CAM Detection Overview What is a CAM (Continuous Air Monitor) for? To detect

More information

Radon Survey Summary Report

Radon Survey Summary Report GWASANAETHAU IECHYD A DIOGELWCH - HEALTH AND SAFETY SERVICES ADRODDIAD REPORT Radon Survey Summary Report September 2010 Gwasanaethau Iechyd a Diogelwch Health and Safety Services, Penbre, Lon y Coleg.

More information

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES MODEL 77 CONTINUOUS FLOW TRITIUM IN WATER SURVEY MONITOR WHEELED CART, TRUCK OR TRAILER MOUNT ALSO AVAILABLE sales@overhoff.com :

More information

Underground Air Radon Monitoring First Experiment

Underground Air Radon Monitoring First Experiment Underground Air Radon Monitoring First Experiment J.-X. Wang & J. J. Simpson University of Guelph December 1, 1995 SNO-STR-95- ^>S"7 Abstract A first measurement of Radon in underground air was made. The

More information

Měření difúze, ultranízké koncentrace a emanace radonu pro podzemní laboratoř

Měření difúze, ultranízké koncentrace a emanace radonu pro podzemní laboratoř Institute of Experimental and Applied Physics CTU in Prague Měření difúze, ultranízké koncentrace a emanace radonu pro podzemní laboratoř Fadahat Mamedov, Ivan Štekl, Karel Smolek 1 Outline Introduction

More information

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc. Love the Lungs You re With 630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: August 27, 2014 to August

More information

Dynamic Radon Detection Over Measurement

Dynamic Radon Detection Over Measurement Dynamic Radon Detection Over Measurement Nuclear Engineer, specialised in detection of nuclear particles, instrumentations and radioprotection. Person in charge of radioprotection. Worked for nuclear industries

More information

Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement

Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement PSAM 2013 Topical Conference in Tokyo GS-III : PSA Applications and Software Reliability (#1079) Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement

More information

Portable Survey Instruments NISP-RP-01

Portable Survey Instruments NISP-RP-01 NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection NISP-RP-01 This is an industry document for standardizing radiation protection processes used by supplemental radiation protection technicians.

More information

Using downhole probing for real-time grade estimation for uranium exploration and mining

Using downhole probing for real-time grade estimation for uranium exploration and mining February 2015 Using downhole probing for real-time grade estimation for uranium exploration and mining Andrew Fitzpatrick Chief Geophysicist cameco.com Radiation 101 2 Using downhole probing for Uranium

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting Method Number: ELAP method number 7036 SOP Number: Revision Number:

More information

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 417 Fifth Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Certificate of Completion

Certificate of Completion Love the Lungs You re With 630-325-4443 800-244-4242 Certificate of Completion Every parent or guardian is notified that this facility has performed radon measurements to ensure the health and safety of

More information

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION 12 WEEKS PRINTED RECORD (Optional) 4 CHANNEL

More information

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 240 Melrose Avenue Aurora, Illinois 60505 Survey Dates: May 1, 2018 thru May 3, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR FEATURES: WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS Protective Action Guideline Levels and Military Drinking Water Limits REAL TIME, IN-LINE, CONTINUOUS DETECTS ALPHAS,

More information

THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA

THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA THE EFFECT OF BUILDING CODES AND HOUSE AGE ON RADON CONCENTRATIONS IN MINNESOTA Daniel J. Steck Physics Department, St. John's University Collegeville, MN 5632 1 ABSTRACT Many public radon reduction programs

More information

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009 RAM GENE-1 ERK MK-Ι & MK-ΙΙ Contamination & Radiation Meter Operating Manual Document #PRIR90N2.DOC Version 2.2 October 2009 Version / Revision Log: RAM GENE-1 ERK/ Operating Manual Ver./Rev.# Date Revised

More information

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor FEATURES: HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS WORLD S ONLY PAG-LEVEL WATER MONITOR MEASURES AT OR BELOW EPA/DHS PAG LEVELS (EPA s PROTECTIVE ACTION GUIDELINE LEVELS) REAL TIME, IN-LINE, CONTINUOUS

More information

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site:July 5, 2018 1200 Front Street Aurora, Illinois 60505 Survey Dates: May 9, 2018 thru May 11, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora,

More information

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 950 Kane Street Aurora, Illinois 60505 Survey Dates: May 15, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Radon Testing Results. City Hall

Radon Testing Results. City Hall Radon Testing Results January April 2016 City Hall LOCATION Radon Concentration Bq/m3 Basement elevator room 152 Boiler room 67 Mail room 60 Training room 78 Electrical room 71 Server room 83 Basement

More information

laboratories radiation. presence disturb radon as results. Measurements of the influence of radon on a that 30 Bq m-3, system using a that generates

laboratories radiation. presence disturb radon as results. Measurements of the influence of radon on a that 30 Bq m-3, system using a that generates EXTERNAL RADON DISTURBANCE OF 14C MEASUREMENTS IN GAS- PROPORTIONAL COUNTERS MAGNUS HEDBERG Swedish Museum of Natural History, Laboratory for Isotope Geology, Box 50007 S-104 05, Stockholm, Sweden and

More information

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings Conducting and Assessing Radon Surveys in Schools & Commercial Buildings CIHC 2015 Annual Conference December 7, 2015 Gustavo A. Delgado, Ph.D. California Radon Measurement Provider Forensic Analytical

More information

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 56 Jackson Street Aurora, Illinois 60505 Survey Dates: May 8, 2018 thru May 10, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For: Radon Measurement Survey Report Site: 501 College Avenue Aurora, Illinois 60505 Survey Dates: May 16, 2018 thru May 18, 2018 Prepared For: East Aurora School District 131 417 Fifth Street Aurora, Illinois

More information

Adaption to scientific and technical progress under Directive 2002/95/EC

Adaption to scientific and technical progress under Directive 2002/95/EC . Adaption to scientific and technical Results previous evaluation Exemption No. 22 Lead as impurity in RIG (rare earth iron garnet) Faraday rotators used for fibre optic communications systems (Excerpt

More information

Application Note. Application Note for BAYEX

Application Note. Application Note for BAYEX Application Note Application Note for BAYEX Preface This application note provides the user a more detailed description of the Bayesian statistical methodology available in Version 8.05 and above, of the

More information

Quality Assurance Plan for Conducting Radon Measurements

Quality Assurance Plan for Conducting Radon Measurements Quality Assurance Plan for Conducting Radon Measurements 921 Pheasant Run Lindsborg, Kansas 67456 (785) 510-0000 info@clarityinspect.com getyourinspection.com page 1 of 18 Table of Contents A.1 Approval

More information

Radon Measurements at Australian Antarctic Stations

Radon Measurements at Australian Antarctic Stations Radon Measurements at Australian Antarctic Stations Brendan Tate Australian Radiation Protection and Nuclear Safety Agency Why Measure Radon in Antarctica? Indoor radon Request from AAD to find out radon

More information

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel Melissa Quinnan August 15, 2015 Supervisor: Michele Bianco Abstract In preparation for the coming High Luminosity Large Hadron Collider

More information

SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES

SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES Radon in the Living Environment, 169 SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES Gilbert Jönsson a, Carmen Baixeras b, Lluis Font b, Diego Albarracin b, Giuseppe

More information

Relevant Radon properties

Relevant Radon properties Relevant Radon properties Radon is a natural gas and has a half life of 3.8 days. This means that if a box was full of radon gas, half of it would have decayed into something else after 3.8 days. It has

More information

Radon measuring to detect coal spontaneous combustion fire source at Bulianta mine, Shendong

Radon measuring to detect coal spontaneous combustion fire source at Bulianta mine, Shendong University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2012 Radon measuring to detect coal spontaneous combustion fire source at Bulianta mine,

More information

What you need to know

What you need to know What you need to know What RADON is The health effects How to test your home How to reduce your risk Protect your health. Test your home. www.regionofwaterloo.ca/radon RADON information What is radon?

More information

International Requirements for the Control of Radon

International Requirements for the Control of Radon Tenth Irish National Radon Forum Thursday 17 January 2013 International Requirements for the Control of Radon Trevor Boal, -NSRW International Atomic Energy Agency Content Safety Standards Requirements

More information

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg. PHY357 Lecture 11 Experimental Methods Accelerators Particle Interactions Particle Detectors Full experiment (eg. ATLAS) Introduction! Several different general classes of particle detectors (sensors)!

More information

A Continuous Air Monitoring Sampler for 125 I - RIS-125

A Continuous Air Monitoring Sampler for 125 I - RIS-125 A Continuous Air Monitoring Sampler for 125 I - RIS-125 S.Levinson, I.Belaish, T.Kravchik, U.German, O.Pelled, Y. Laichter, Y.Mazor, U.Wengrowicz, E.Dolev, H.Assido, D.Tirosh Nuclear Research Center Negev,

More information

Outdoor radon concentration in China

Outdoor radon concentration in China NUKLEONIKA 2016;61(3):373 378 doi: 10.1515/nuka-2016-0062 ORIGINAL PAPER Outdoor radon concentration in China Qifan Wu, Ziqiang Pan, Senlin Liu, Chunhong Wang Abstract. A nationwide survey was conducted

More information

Situation on Radon Assessment in Latvia

Situation on Radon Assessment in Latvia Situation on Radon Assessment in Latvia Žanna Martinsone Institute of Occupational Safety and Environmental Health, Riga Stradins University, LATVIA e-mail: Zanna.Martinsone@rsu.lv Regional workshop on

More information

A new passive integrating detector for measurement of individual radon exposure at working places.

A new passive integrating detector for measurement of individual radon exposure at working places. A new passive integrating detector for measurement of individual radon exposure at working places. G. Sciocchetti, G. Cotellessa, E. Soldano, M. Pagliari and A. Ceccatelli (*) ENEA-ION-IRP, Centro Ricerche

More information

Institute of Industrial Science, University of Tokyo Bulletin of ERS, No. 45 (2012) FAILURE OF CEILINGS IN AN AIRPORT BUILDING DURING THE 2011 OFF THE

Institute of Industrial Science, University of Tokyo Bulletin of ERS, No. 45 (2012) FAILURE OF CEILINGS IN AN AIRPORT BUILDING DURING THE 2011 OFF THE Institute of Industrial Science, University of Tokyo Bulletin of ERS, No. 45 (2012) FAILURE OF CEILINGS IN AN AIRPORT BUILDING DURING THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE AND ESTIMATION

More information

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E Thermo Fisher Scientific Messtechnik GmbH Frauenauracher Straße 96 91056 Erlangen Germany www.thermo.com info.rmp.erlangen@thermofisher.com

More information

Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC

Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC Silicon Drift Detector of ALICE Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC Emanuele Biolcati for ALICE collaboration Dipartimento di Fisica dell Università di Torino

More information

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

COMPANY PROFILE.   DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY monitoring for safety COMPANY PROFILE DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS ENVIRONMENTAL MONITORING HEALTH AND ENVIRONMENTAL SAFETY www.rtsinstruments.com 2 monitoring

More information

Sensitivity to Thoron on Passive Radon Detectors

Sensitivity to Thoron on Passive Radon Detectors Sensitivity to Thoron on Passive Radon Detectors S. Tokonami 1, H. Yonehara 1, T. Sanada 2, M. Yang 3, M. Furukawa 1 and Y. Yamada 1 1 National Institute of Radiological Sciences, Chiba 263-8555, Japan

More information

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S) Ganibu Dambis 26, P.O.Box 33 Riga, LV-1005, LATVIA Tel. (+371)6738-3947 Fax:(+371)6738-2620 office@bsi.lv www.bsi.lv CONTENTS INTRODUCTION...

More information

Safety Siren Pro Series3 Radon Gas Detector

Safety Siren Pro Series3 Radon Gas Detector Safety Siren Pro Series3 Radon Gas Detector Model Numbers HS71512 USA HS79712 Canada Table of Contents Facts and Concerns Regarding Radon Gas 2 Location of the Detector 2 Areas to Avoid 3 Installation

More information

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION SEAWATER RADIATION DETECTION SYSTEM FEATURES: MEASURES AT OR BELOW EPA/DHS PAG LEVELS Protective Action Guideline & Military Drinking Water Limits REAL TIME, IN-LINE, CONTINUOUS DETECTS ALPHAS, BETAS AND

More information

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS Hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable

More information

Re: ENSC440 Functional Specification for a License Plate Recognition Auto-gate System

Re: ENSC440 Functional Specification for a License Plate Recognition Auto-gate System February 16 th, 2009 Mr. Patrick Leung School of Engineering Science Simon Fraser University 8888 University Drive Burnaby BC V5A 1S6 Re: ENSC440 Functional Specification for a License Plate Recognition

More information